Next Article in Journal
Salutogenesis at Work as a Facilitator for Implementation? An Explorative Study on the Relationship of Job Demands, Job Resources and the Work-Related Sense of Coherence within a Complex Healthcare Programme
Next Article in Special Issue
Fixed-Bed Adsorption of Lead from Aqueous Solution Using Chitosan-Coated Bentonite
Previous Article in Journal
Stigma towards Mental Disorders among Nursing Students and Professionals: A Bibliometric Analysis
Previous Article in Special Issue
Optimization of Micro-Pollutants’ Removal from Wastewater Using Agricultural Waste-Derived Sustainable Adsorbent
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electrochemical Disinfection of Simulated Ballast Water Using RuO2-TiO2/Ti Electrode

by
Sivasankar Annamalai
1,
Cybelle Concepcion Futalan
2 and
Yeonghee Ahn
1,*
1
Department of Environmental Engineering, Dong-A University, Busan 49315, Korea
2
Department of Community and Environmental Resource Planning, University of the Philippines, Los Baños 4031, Philippines
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2022, 19(3), 1835; https://doi.org/10.3390/ijerph19031835
Submission received: 11 January 2022 / Revised: 3 February 2022 / Accepted: 4 February 2022 / Published: 6 February 2022

Abstract

:
The present work investigated the treatment of ballast water via electrochemical disinfection using a RuO2-TiO2/Ti electrode. Batch tests were conducted with simulated ballast water containing Escherichia coli as an indicator organism. The effect of varying NaCl concentrations (1%, 2%, and 3%; w/v) and current densities (0.3, 1.0, 2.0, and 3.0 mA/cm2) on the inactivation of E. coli was examined. Results showed higher disinfection efficiency of E. coli was obtained at higher NaCl concentration and current density. Complete inactivation of E. coli was attained within 2 and 1 min at 0.3 and 1 mA/cm2, respectively, under 3% NaCl concentration. Meanwhile, complete disinfection at 1 and 2% NaCl concentrations was observed in 6 and 2 min, respectively, using a current density of 0.3 mA/cm2. The 100% inactivation of E. coli was achieved with an energy consumption in the range of 2.8 to 2.9 Wh/m3 under the NaCl concentrations at 1 mA/cm2 and 1 min of electrolysis time. The complete disinfection attained within 1 min meets the D-2 standard (<250 CFU E. coli/100 mL) of ballast water under the International Maritime Organization. The values of energy consumption of the present work are lower than previous reports on the inactivation of E. coli from simulated ballast water.

1. Introduction

Ballast water is fresh, or seawater held in the ballast tanks of ships [1]. It provides stability and maneuverability to the ships during a voyage. Approximately 10 billion tons of ballast water is discharged annually into the marine environment since ships transport 80% of the globally traded goods and merchandise [1,2]. Ballast tanks were reported to contain a minimum of 7000 various species that were transported worldwide daily according to the International Maritime Organization (IMO) [1,2]. The organisms (e.g., zooplankton, bacteria, dinoflagellates, larvae, etc.) in ballast water were shown to survive during transportation [3,4,5]. The ballast water discharge affects the marine environment, ecology, economy, and human health since ballast water carries invasive species along with pathogens to aquatic organisms and humans [1,2].
IMO adopted the International Convention for the Control and Management of Ships’ Ballast Water and Sediments (BWM Convention) in 2004 to introduce global regulations to control the transfer of potentially invasive species [6]. All ships in international traffic need to manage their ballast water since the BWM Convention entered into force globally. Under the Convention, new ships built on or after 8 September 2017 must meet the D-2 standard while all ships must meet the standard by 8 September 2024. The D-2 standard specifies the maximum concentration of viable organisms allowed to be discharged, including specified indicator microorganisms (e.g., <250 CFU E. coli/100 mL; <1 CFU Vibrio cholera/100 mL) [2,6].
Various technologies were employed to inactivate and disinfect aquatic organisms and microbes in ballast water [1,2,7,8,9,10]: ultraviolet radiation, biocide application, sonication, filtration, ozone treatment, and chemical method. Currently, these methods have limitations such as toxic by-product formation, large space requirement, high energy consumption, low treatment efficiency, and chemical storage requirement. In recent years, previous reports on electrochemical studies have shown that electrochemical treatment can effectively remove contaminants or pathogens from the environment [11,12,13]. Electrochemical disinfection has gained increasing attention due to its ability to inactivate and remove various living organisms and pathogens from water [13,14]. However, it is an emerging method for ballast water treatment.
Electrochemical disinfection uses suitable electrode materials to create a direct current (DC) electric field that flows the water and inactivates microorganisms. It has numerous advantages such as easy operation and installation, simple instruments, and high treatment efficiency [2,13,14,15]. In addition, electrochemical disinfection has a small energy requirement, which makes it cost-effective and environmentally compatible that could be sustained using fuel cells or solar cells [2,13,14,15,16]. More importantly, electrochemical disinfection can produce oxidizing species in situ that would not require the storage and transport of chemicals [2,14]. Since seawater, which is commonly used as ballast water, naturally contains chloride ions, the production of chlorine species such as hypochlorous acid (HOCl) and hypochlorite (ClO) during electrochemical disinfection is an advantage [2,14]. The inactivation efficiency of the process is attributed to electrochemical chlorination and the presence of reactive oxygen species (e.g., hydrogen peroxide, hydroxyl radicals). The generation of both chlorine species and reactive oxygen species would cause the deterioration of the microbial cell wall and membrane, which leads to cell lysis [13,14,17].
Selecting a proper anodic material is essential in the electrochemical process since it affects the process efficiency and the formation of electroactive chlorine species (e.g., HClO, ClO, Cl2) that would be generated when chloride salts are present [13,14,18,19]. Researchers investigated various anode materials for ballast water treatment: boron-doped diamond (BDD), PbO2, graphite, platinum (Pt), and metal oxide coated titanium electrodes [13,20,21,22]. When PbO2/graphite felt anode was employed to treat the artificial seawater (3% NaCl), the complete inactivation of E. coli, Enterococcus faecalis, and Artemia salina was achieved at 8, 60, and 40 min, respectively, using a current density of 25.3 mA/cm2 [21]. Lacasa et al. [22] reported that 100% disinfection of E. coli was attained within 5 min using BDD to treat simulated ballast water (3% NaCl). The energy consumption was determined to be 42 Wh/m3 at the current density of 12.7 mA/cm2.
Dimensionally stable anodes (DSAs) are comprised of a titanium substrate coated with inorganic metal oxides (e.g., SnO2, IrO2-Sb2O5-SnO2, TiO2-RuO2, and IrO2-RuO2) and are known for their resistance to corrosion and superior electrical conductivity [17,23,24]. DSAs have been widely applied for the disinfection of water [15,17,23,24]. When compared to other stable anodes like Pt and BDD, DSAs have higher efficiency in generating chlorine species and better disinfection dosage that allow the process to be operated at a lower voltage range and decreased energy consumption [25,26]. DSAs commonly use conductive metal oxides such as TiO2, IrO2, and RuO2 as coating film. The combination of metal oxides would develop a synergistic, bifunctional anode that is both electrocatalytic and photocatalytic. The application of RuO2 in industries is associated with its excellent conductivity, high electrocatalytic activity, and exceptional stability [27,28,29]. Previous studies mainly used electrodes with the mole ratio of 30:70 for RuO2 and TiO2 to degrade organic contaminants for wastewater treatment [30]. There are no studies performed on the varying molar ratio of RuO2 that could further improve the electrocatalytic activity of the anode material and enhance the disinfection efficiency for ballast water treatment.
Studies on better methods for ballast water treatment are very much necessary before the implementation of D-2 compliance in all the ships. In this regard, this study prepared mixed metal oxide (RuO2-TiO2/Ti; 45 mol % RuO2 + 55 mol % TiO2) as the anode material and investigated its performance to disinfect simulated ballast water containing E. coli in the electrochemical process. The prepared RuO2-TiO2/Ti anode was characterized using a scanning electron microscope (SEM) and energy-dispersive x-ray spectroscopy (EDS). The inactivation efficiency of E. coli was investigated under varying process parameters such as current density and NaCl concentration. The energy consumption and decay of E. coli under different salinity were also determined.

2. Materials and Methods

2.1. Preparation and Characterization of Electrode

The mixed metal oxide of RuO2-TiO2/Ti expanded mesh anode was prepared by pyrolysis of titanium tetrachloride (TiCl4) and ruthenium trichloride (RuCl3) on titanium (Ti) substrate. To attain a rough surface, the expanded Ti mesh was sandblasted and etched with 10% HCl for 3 min at 80 °C. Then, the chemically-etched Ti expanded mesh was washed with distilled water and air-dried. After which, the dissolution of RuCl3 and TiCl4 (concentration of 45:55 mol %) in isopropanol was carried out. The solution mixture was brushed on the surface of the pretreated Ti expanded mesh. Then, the electrode was burnt at 400 °C for 10 min at O2 atmosphere and was air-dried for 10 min. This step was repeated until a thickness of 6 μm coating layer was obtained [31]. Finally, the final firing was done at 420 °C for 1 h. The electrode surface of the RuO2-TiO2/Ti expanded mesh anode was analyzed by SEM (Hitachi SU-70, Hitachi High-Technologies, Tokyo, Japan) and EDS (INCA, Oxford Instruments, Oxfordshire, UK).

2.2. Bacterial Strains and Growth Conditions

E. coli CN13 was employed as an indicator organism in this study. A single colony of the strain grown on a Luria Bertani (LB) agar plate was inoculated into 500 mL of sterile LB broth and cultured at 37 °C in a shaking incubator at 150 rpm for 48 h. The cells were harvested by centrifugation (Model Mega 17R; Hanil, Daejeon, Korea) for 10 min at 10,000 rpm and 20 °C. The harvested cells were washed and resuspended in varying NaCl solutions (1, 2, and 3%; w/v) that were used as the background electrolyte. NaCl solutions were prepared with deionized water [17,21]. The bacterial suspensions (~1 × 107 CFU/mL) in the NaCl solutions were used for the disinfection tests.

2.3. Set-Up of the Electrochemical Reactor

The present work employed an electrochemical reactor similar to the set-up described previously [17,21]. Batch electrolysis experiments were carried out in a 300 mL beaker (undivided cell) with a working volume of 250 mL. The simulated ballast water was prepared as described for NaCl solutions [17,21]. The prepared RuO2-TiO2/Ti expanded mesh served as the anode, while Ti expanded mesh was used as the cathode. An inter-electrode distance of 1 cm was maintained between the anode and cathode, which were placed parallel to each other.

2.4. Disinfection Experiments

Before the start of each experiment, sonication of the electrode was performed for 10 min in deionized water to eliminate residual contamination on the electrode surface. The electrochemical disinfection experiments were carried out under constant bacterial concentration (~1 × 107 CFU/mL) and varying current densities (0, 0.3, 1, 2, and 3 mA/cm2) in a galvanostatic mode with a regulated DC power source (Model OPE-303QI; ODA Technologies, Incheon, Korea). The electrolyte solution was constantly stirred at 150 rpm using a magnetic stirrer. The samples were collected periodically and the potential was measured. The standard analytical procedure (Iodometric method) was employed to analyze the electroactive chlorine species [21]. All experiments were conducted in triplicate.

2.5. Bacterial Sample Analysis

The plate counting method was used to measure E. coli concentration in the ballast water before and after each experiment. Samples were collected at specific time intervals: 0.5, 1, 2, 3, 4, 5, 10, 20, and 30 min. During sample collection and handling, an equal volume of 1 N Na2S2O3 was added immediately in the samples to remove residual free chlorine and prevent the death of microbes [32]. Then, the samples were serially diluted for microbial analysis. Each dilution of 100 µL was spread onto an LB agar plate and incubated at 35 °C for 14 h. The colonies grown on the plates were counted.

3. Results and Discussion

3.1. Characterization and Surface Morphology Analysis

The surface morphology of the prepared mixed metal oxide electrode (RuO2-TiO2/Ti) clearly showed a rough surface morphology with several muddy cracks on the coated electrode (Figure 1). The presence of the cracks increases the surface area of the anode and increases the number of active sites exposed [30]. The EDS analysis verified the presence of Ti and Ru (Figure 1). The phase composition was calculated using element-to-stoichiometric oxide conversion factors. Results show that the electrode surface was comprised of ~75% of Ti and 25% of Ru. During the electrolysis process, the anodic potential was determined to be within the ranges of 1.11–1.34 V, 1.19–1.38 V, and 1.2–1.4 V for 1%, 2%, and 3% NaCl, respectively. The result of potential measurements suggested that RuO2–TiO2/Ti anode could form electroactive chlorine species [33].

3.2. Effect of Current Density

Figure 2 shows the effect of current density as a function of time on E. coli disinfection. Increasing the current density from 0.3 to 3.0 mA/cm2 showed better inactivation efficiency of E. coli. In addition, longer contact time also results in better inactivation of E. coli. Complete inactivation of E. coli was achieved within 1 min when the current density was increased from 0.3 to 1 mA/cm2 in all systems. E. coli concentration in 1% NaCl solution decreased gradually within 4 min with a current density of 0.3 mA/cm2 and showed complete disinfection at 6 min of electrolysis (Figure 2a). Meanwhile, a shorter time (2 min) was needed to attain complete disinfection for 2% and 3% NaCl solutions with the same current density (Figure 2b,c).
Faster reduction of E. coli concentration was observed with higher current density due to increased production of electroactive chlorine species and presence of a high number of oxidizing species as well as higher residual chlorine concentration, which can easily disinfect available microbes. In addition, a higher amount of electrical charge will run through the electrolyte with the application of higher current density that could lead to quicker disinfection rates [21]. Similar results were observed by Ghasemian et al. [17] where the disinfection of E. coli D21 using Sb-doped Sn80%-W20%-oxide anode at different current densities was investigated. The complete disinfection of E. coli D21 in 0.1M NaCl was obtained at 60, 5, and 2 min with the current density of 1, 2, and 4 mA/cm2, respectively. In this study, lower values of current density such as 0.3 mA/cm2 were sufficient for the effective inactivation of E. coli in simulated ballast water. The utilization of lower current density may avoid higher energy consumption for the disinfection process. The complete inactivation of E. coli was attained with 2 min contact time, 0.3 mA/cm2, and 2% NaCl concentration, which meets the IMO D-2 standard (<250 CFU/100 mL).
Bacterial decay occurred with respect to time even without applying current in the reactor due to a low nutrient and/or a highly saline environment. The bacterial concentration in the control (0 mA/cm2 applied) slowly decreased from 1.50 × 107 to 1.41 × 107, 1.54 × 107 to 1.35 × 107 and ~1.67 × 107 to 1.14 × 107 CFU/mL for 1%, 2%, and 3% NaCl, respectively.

3.3. Kinetics of E. coli Inactivation

The inactivation kinetics of E. coli under varying current density and NaCl concentration was investigated. Chick’s law is used to determine the kinetic constants for the inactivation of microorganisms as provided in Equation (1) [34].
l o g 10 ( N t N 0 ) = K t
where Nt is the concentration of E. coli at time t, N0 is the initial concentration of E. coli; K is death rate (min−1), and t is time (min). Figure 3 shows that experimental data points are in good agreement with the regression lines, which indicates that the first-order kinetic equation is a good fit in describing the inactivation of E. coli. The kinetic equations and regression coefficients are presented in Table 1. Results show that the high values of the coefficient of determination (R2 ≥ 0.92) were obtained when no current density was applied, while values of R2 ≥ 0.79 were attained for a current density of 0.3 mA/cm2. The high R2 values imply that first-order kinetics would best describe the inactivation of E. coli for both systems. This indicates that the disinfection of E. coli is controlled by mass transfer or generated reagents (e.g., electroactive chlorine species, oxidizing species) [22]. The values of the kinetic constant (K) were determined to be in the ranges of 0.0063–0.0087 min−1 for 0 mA/cm2 and 0.7076–4.8286 min−1 for 0.3 mA/cm2. Higher K values obtained at higher salinity and higher current density indicated better inactivation efficiency of E. coli. Lacasa et al. [22] reported similar findings where the mortality rate of E. coli increased with increasing current density and salinity.

3.4. Effect of NaCl Concentration

Figure 4 shows the effect of NaCl concentration on E. coli disinfection and the production of electroactive chlorine substances at a current density of 0.3 mA/cm2. It was observed that increasing the NaCl concentration would lead to better inactivation efficiency of E. coli. Results show that the E. coli concentration decreased from ~1.50 × 107 to 0.0037 × 107, ~1.54 × 107 to 0.00018 × 107, and ~1.67 × 107 to 0.0001 × 107 CFU/mL for 1%, 2%, and 3% NaCl, respectively, at 1 min of electrolysis. A shorter contact time of 2 min was needed to obtain complete disinfection for both 2% and 3% NaCl while a longer contact time of 6 min was required for 1% NaCl. Increasing the NaCl concentration from 1% to 3% indicates that a higher amount of electroactive chlorine species would be generated; thus, a shorter contact time is required for the complete inactivation of E. coli.
As the NaCl concentration was increased from 1 to 3% at a fixed current density of 0.3 mA/cm2, a corresponding increase in the electroactive chlorine species concentration was also observed (Figure 4). For the first 4 min, no electroactive chlorine species were observed in 1% NaCl (Figure 4a). After 5 min of electrolysis, 3 mg/L of electroactive chlorine species were measured. Similarly, electroactive chlorine species were not detected at 0.5 min of electrolysis in 2 and 3% NaCl system (Figure 4b,c). This indicates that the electroactive chlorine species were almost completely utilized for the disinfection of E. coli during the start of the process. After complete disinfection was attained at 2 min for 2% and 3% NaCl and 6 min for 1% NaCl, the concentration of electroactive chlorine was observed to increase gradually.
Table 2 shows the concentration of electroactive chlorine species under varying current densities and NaCl concentrations after 30 min contact time. The available electroactive chlorine species generated with 0.3 mA/cm2 was determined to be 17.5, 22.3, and 31.9 mg/L at 1%, 2%, and 3% NaCl, respectively. A high NaCl concentration and high current density generated an increased amount of electroactive chlorine species. The highest value of electroactive chlorine species (262.35 ± 41.36 mg/L) was attained at 3% NaCl and 3.0 mA/cm2. The previous study also showed similar results where complete disinfection of E. coli in simulated ballast water at 3% NaCl was attained at 8 min of electrolysis using PbO2/graphite electrode at 25.3 mA/cm2 [21]. Meanwhile, the present study obtained 100% inactivation of E. coli after 2 min of electrolysis using RuO2-TiO2/Ti anode at 0.3 mA/cm2.

3.5. Mechanism of E. coli Inactivation

The present study used RuO2-TiO2/Ti and Ti mesh as anode and cathode, respectively. As the current is applied, electro-migration occurs where the movement of the chloride ions towards the anode occurs. The production of a chlorine molecule (Cl2) takes place due to the interaction of Cl- with the electrode surface via direct oxidation (Equation (2)). Simultaneously, OH ions are formed due to the reduction of water molecules at the cathode (Equation (3)). At the anode, the dissolution of the Cl2 gas in water would lead to the formation of electroactive chlorine species such as HOCl and ClO (Equations (4) and (5)) that are well-known for their bactericidal effects on microorganisms.
Cl + Cl Cl 2 + 2 e   ( Anodic   reaction )
2 H 2 O + 2 e - H 2 + 2 OH   ( Cathodic   reaction )
Cl 2 + H 2 O   H + + Cl + HOCl   ( pH   <   7 )
Cl 2 + O   H - ClO + H + + Cl
HOCl H + + ClO   ( pH   >   7 )
Another mechanism of inactivation is via electronic adsorption of microorganisms that are negatively charged onto the anodic surface of the electrode. Cell lysis is caused by the direct transfer of electrons after E. coli cells have attached to the anodic surface [35]. Previous reports have shown that the essential mechanism for the inactivation of microorganisms involves electrolyzed chlorine and hydroxyl radicals [36,37]. Particularly, studies on electrochemical disinfection using DSAs have shown that the vital inactivation mechanism is via chlorination in wastewater and surface waters [22,38].
The pH of the electrochemical system was monitored after 30 min of the electrochemical disinfection process at varying current densities and NaCl concentrations. The control system (0 mA/cm2) used in this study showed a constant pH of 5.8 ± 0.05 (Figure 5). The pH of the system seems unaffected under different NaCl concentrations. The pH of the system was determined to be approximately 6.4, 7.2, 8.4, and 9.0, with current density at 0.3, 1, 2, and 3 mA/cm2, respectively. When low current density (0.3 and 1 mA/cm2) is applied, the pH of the system is neutral (~pH 7.0). Meanwhile, a more basic pH of the solution was observed at a higher current density (2 and 3 mA/cm2) due to the formation of hydroxide ions (OH-) at the cathode caused by a reduction reaction. Basic conditions such as pH > 8.0 would result in the preferential adsorption of OH- ions onto the anode surface, which in turn, would cause low chlorine generation and decreased disinfection efficiency [2,39]. Most importantly, the stability of the electroactive chlorine species (e.g., HOCl, ClO) is highly dependent on the pH of the electrolyte. Chlorine species such as HOCl and ClO are more stable in acidic and basic conditions, respectively. Acidic conditions tend to produce a higher concentration of HOCl while basic conditions would lead to the formation of ClO. Meanwhile, both ClO and HOCl have been determined to be present in the solution with neutral pH. Therefore, acidic and neutral conditions are considered to favor improved inactivation efficiency. In the present work, the application of low current densities (0.3 and 1 mA/cm2) with acidic to neutral pH implies the system is conducive to the formation of both ClO- and HOCl. Overall, the measured pH for all systems was less than 9, indicating higher production of electroactive chloride species to be utilized in the disinfection of E. coli.

3.6. Energy Consumption and Cost Analysis

In general, improved bacterial disinfection is associated with the application of high current density that would result in increased energy consumption. The cost-effectiveness of the electrochemical disinfection process using RuO2-TiO2/Ti in the disinfection of E. coli was examined by determining the energy consumption. The energy consumption (E, Wh/m3) is computed using Equation (7) [18,30]:
E n e r g y   c o n s u m p t i o n   ( E ) = 1 V s V   I   d t
where Vs is the volume of sample processed, V is the voltage difference between the electrodes and I is the electric current.
The energy input to obtain complete bacterial disinfection was determined to be in the range of 2.9–10.4 Wh/m3 (1% NaCl), 2.8–8.7 Wh/m3 (2% NaCl) and 2.8–8.0 Wh/m3 (3% NaCl) under various current densities (0.3–3 mA/cm2). The lowest power consumption of 2.8 Wh/m3 using RuO2-TiO2/Ti anode was able to attain 100% bacterial disinfection of 1 × 107 CFU/mL E. coli under the following conditions: 1 mA/cm2 of current density, 2% to 3% NaCl concentrations, and 1 min of electrolysis time. The values of energy consumption obtained in the present work are lower when compared to previous reports. Heim et al. [40] reported that complete disinfection of E. coli (107–108 CFU/mL) in municipal wastewater was achieved with an energy consumption of 250 Wh/m3 under different NaCl concentrations (2% and 3%) using BDD. About 88 Wh/m3 of energy input was required in the study of Lacasa et al. [22] to obtain complete inactivation of E. coli (106–107 CFU/mL) using BBD at 3% (w/v) NaCl. The present work demonstrated that 1 mA/cm2 of current is sufficient to attain 100% disinfection of E. coli in the simulated ballast water.

4. Conclusions

In the present study, RuO2-TiO2/Ti anode (45 mol % RuO2 + 55 mol %TiO2) was developed and used in the electrochemical disinfection of E. coli from simulated ballast water. Results show that increasing the NaCl concentration (0–3%; w/v) and current density (0.3–3.0 mA/cm2) would cause better inactivation efficiency of E. coli under shorter electrolysis time due to the production of higher concentration of electroactive chlorine species and oxidizing species in the system. The concentration of the total electroactive chlorine species present during electrochemical disinfection was determined to be within the range of 17.50–262.35 mg/L under varying current densities and NaCl concentrations. Complete disinfection of E. coli was achieved at a shorter contact time of 2 min for both 2% and 3% NaCl while a longer contact time of 6 min was needed for 1% NaCl at a current density of 0.3 mA/cm2. The energy input required to attain complete disinfection of E. coli was determined to be 2.9 ± 0.07, 2.8 ± 0.,07 and 2.8 ± 0.10 Wh/m3 for 1%, 2%, and 3% NaCl, respectively, using a current density of 1 mA/cm2 and 1 min of electrolysis time. The energy consumption values in the present work are lower when compared to those in previous reports in the inactivation of E. coli from simulated ballast water. In the present study, 100% disinfection of E. coli was attained in 1 min at 1 mA/cm2 that meets the IMO D-2 standard (<250 CFU E. coli/100 mL) of ballast water.

Author Contributions

Conceptualization, S.A. and Y.A.; methodology, S.A.; investigation, S.A.; resources, Y.A.; data curation, S.A.; writing—original draft preparation, S.A.; writing—review and editing, C.C.F. and Y.A.; supervision, Y.A.; project administration, Y.A.; funding acquisition, Y.A. All authors have read and agreed to the published version of the manuscript.

Funding

This paper was supported by the Dong-A University Research Fund, in 2019.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are within the article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Lakshmi, E.; Priya, M.; Achari, V.S. An overview on the treatment of ballast water in ships. Ocean Coast. Manag. 2021, 199, 105296. [Google Scholar] [CrossRef]
  2. Sayinli, B.; Dong, Y.; Park, Y.; Bhatnagar, A.; Sillanpää, M. Recent progress and challenges facing ballast water treatment—A review. Chemosphere 2021, 132776. [Google Scholar] [CrossRef]
  3. Ruiz, G.M.; Fofonoff, P.W.; Carlton, J.T.; Wonham, M.J.; Hines, A.H. Invasion of coastal marine communities in North America: Apparent patterns, processes, and biases. Annu. Rev. Ecol. Evol. Syst. 2000, 31, 481–531. [Google Scholar] [CrossRef] [Green Version]
  4. Hallegraeff, G.M.; Bolch, C.J. Transport of toxic dinoflagellate cysts via ships’ ballast water. Mar. Pollut. Bull. 1991, 22, 27–30. [Google Scholar] [CrossRef]
  5. Miller, A.W.; Frazier, M.; Smith, G.E.; Perry, E.S.; Ruiz, G.M.; Tamburri, M.N. Enumerating sparse organisms in ships’ ballast water: Why counting to 10 is not so easy. Environ. Sci. Technol. 2011, 45, 3539–3546. [Google Scholar] [CrossRef] [PubMed]
  6. Gollasch, S.; David, M.; Voigt, M.L.; Dragsund, E.; Hewitt, C.L.; Fukuyo, Y. Critical review of the IMO international convention on the management of ships’ ballast water and sediments. Harmful Algae 2007, 6, 585–600. [Google Scholar] [CrossRef]
  7. Martinez, L.F.; Mahamud, M.M.; Lavin, A.G.; Bueno, J.L. The regrowth of phytoplankton cultures after UV disinfection. Mar. Pollut. Bull. 2013, 67, 152–157. [Google Scholar] [CrossRef]
  8. Chelossi, E.; Faimali, M. Comparative assessment of antimicrobial efficacy of new potential biocides for treatment of cooling and ballast waters. Sci. Total Environ. 2006, 356, 1–10. [Google Scholar] [CrossRef]
  9. Shah, A.D.; Liu, Z.Q.; Salhi, E.; Höfer, T.; Werschkun, B.; Von Gunten, U. Formation of disinfection by-products during ballast water treatment with ozone, chlorine, and peracetic acid: Influence of water quality parameters. Environ. Sci. Water Res. Technol. 2015, 1, 465–480. [Google Scholar] [CrossRef]
  10. Gavand, M.R.; McClintock, J.B.; Amsler, C.D.; Peters, R.W.; Angus, R.A. Effects of sonication and advanced chemical oxidants on the unicellular green alga Dunaliella tertiolecta and cysts, larvae and adults of the brine shrimp Artemia salina: A prospective treatment to eradicate invasive organisms from ballast water. Mar. Pollut. Bull. 2007, 54, 1777–1788. [Google Scholar] [CrossRef]
  11. Nguyen, V.K.; Ahn, Y. Electrochemical removal and recovery of iron from groundwater using non-corrosive electrodes. J. Environ. Manag. 2018, 211, 36–41. [Google Scholar] [CrossRef] [PubMed]
  12. Nguyen, V.K.; Ha, M.; Shin, S.; Seo, M.; Jang, J.; Jo, S.; Kim, D.; Lee, S.; Jung, Y.; Kang, P.; et al. Electrochemical effect on bioleaching of arsenic and manganese from tungsten mine wastes using Acidithiobacillus spp. J. Environ. Manag. 2018, 223, 852–859. [Google Scholar] [CrossRef] [PubMed]
  13. Martínez-Huitle, C.A.; Brillas, E. A critical review over the electrochemical disinfection of bacteria in synthetic and real wastewaters using a boron-doped diamond anode. Curr. Opin. Solid State Mater. Sci. 2021, 25, 100926. [Google Scholar] [CrossRef]
  14. Bergmann, H. Electrochemical disinfection—State of the art and tendencies. Curr. Opin. Electrochem. 2021, 28, 100694. [Google Scholar] [CrossRef]
  15. Särkkä, H.; Vepsäläinen, M.; Pulliainen, M.; Sillanpää, M. Electrochemical inactivation of paper mill bacteria with mixed metal oxide electrode. J. Hazard. Mater. 2008, 156, 208–213. [Google Scholar] [CrossRef] [PubMed]
  16. Nanayakkara, K.G.N.; Alam, A.K.M.K.; Zheng, Y.M.; Chen, J.P. A low-energy intensive electrochemical system for the eradication of Escherichia coli from ballast water: Process development, disinfection chemistry, and kinetics modeling. Mar. Pollut. Bull. 2012, 64, 1238–1245. [Google Scholar] [CrossRef] [PubMed]
  17. Ghasemian, S.; Asadishad, B.; Omanovic, S.; Tufenkji, N. Electrochemical disinfection of bacteria-laden water using antimony-doped tin-tungsten-oxide electrodes. Water Res. 2017, 126, 299–307. [Google Scholar] [CrossRef] [Green Version]
  18. Annamalai, S.; Santhanam, M.; Sudanthiramoorthy, S.; Pandian, K.; Pazos, M. Greener technology for organic reactive dye degradation in textile dye-contaminated field soil and in-situ formation of “electroactive species” at the anode by electrokinetics. RSC Adv. 2016, 6, 3552–3560. [Google Scholar] [CrossRef]
  19. Feng, Y.; Yang, L.; Liu, J.; Logan, B.E. Electrochemical technologies for wastewater treatment and resource reclamation. Environ. Sci. Water Res. Technol. 2016, 2, 800–831. [Google Scholar] [CrossRef]
  20. Schmalz, V.; Dittmar, T.; Haaken, D.; Worch, E. Electrochemical disinfection of biologically treated wastewater from small treatment systems by using boron-doped diamond (BDD) electrodes—Contribution for direct reuse of domestic wastewater. Water Res. 2009, 43, 5260–5266. [Google Scholar] [CrossRef] [PubMed]
  21. Chen, S.; Hu, W.; Hong, J.; Sandoe, S. Electrochemical disinfection of simulated ballast water on PbO2/graphite felt electrode. Mar. Pollut. Bull. 2016, 105, 319–323. [Google Scholar] [CrossRef] [PubMed]
  22. Lacasa, E.; Tsolaki, E.; Sbokou, Z.; Rodrigo, M.A.; Mantzavinos, D.; Diamadopoulos, E. Electrochemical disinfection of simulated ballast water on conductive diamond electrodes. Chem. Eng. J. 2013, 223, 516–523. [Google Scholar] [CrossRef]
  23. Gusmão, I.C.C.P.; Moraes, P.B.; Bidoia, E.D. Studies on the electrochemical disinfection of water containing Escherichia coli using a dimensionally stable anode. Braz. Arch. Biol. Technol. 2010, 53, 1235–1244. [Google Scholar] [CrossRef]
  24. Watts, R.J.; Finn, D.D.; Wyeth, M.S.; Teel, A.L. Performance comparison of tin oxide anodes to commercially available dimensionally stable anodes. Water Environ. Res. 2008, 80, 490–496. [Google Scholar] [CrossRef] [PubMed]
  25. Hand, S.; Cusick, R.D. Electrochemical disinfection in water and wastewater treatment: Identifying impacts of water quality and operating conditions on performance. Environ. Sci. Technol. 2021, 55, 3470–3482. [Google Scholar] [CrossRef] [PubMed]
  26. Sirés, I.; Brillas, E.; Oturan, M.A.; Rodrigo, M.A.; Panizza, M. Electrochemical advanced oxidation processes: Today and tomorrow. A review. Environ. Sci. Pollut. Res. 2014, 21, 8336–8367. [Google Scholar] [CrossRef]
  27. Dai, Q.; Bai, S.; Wang, Z.; Wang, X.; Lu, G. Catalytic combustion of chlorobenzene over Ru-doped ceria catalysts. Appl. Catal. B Environ. 2012, 126, 64–75. [Google Scholar] [CrossRef]
  28. Lee, Y.; Suntivich, J.; May, K.J.; Perry, E.E.; Shao-Horn, Y. Synthesis and Activities of Rutile IrO2 and RuO2 Nanoparticles for Oxygen Evolution in Acid and Alkaline Solutions. J. Phys. Chem. Lett. 2012, 3, 399–404. [Google Scholar] [CrossRef]
  29. Panić, V.V.; Jovanović, V.M.; Terzić, S.I.; Barsoum, M.W.; Jović, V.D.; Dekanski, A.B. The properties of electroactive ruthenium oxide coatings supported by titanium-based ternary carbides. Surf. Coat. Technol. 2007, 202, 319–324. [Google Scholar] [CrossRef]
  30. Santhanam, M.; Annamalai, S.; Sudanthiramoorthy, S.; Gopalakrishnan, R. A simple strategy for monitoring of aromatic degradation in chloride mediated electrooxidation process. RSC Adv. 2015, 5, 75528–75532. [Google Scholar] [CrossRef]
  31. Subbiah, P.; Krishnamurthy, S.; Asokan, K.; Subramanian, K.; Arumugam, V. An Improved Process for the Preparation of Insoluble Non-Precious Metal Oxide Anode Doped with Platinum Group Metal Oxide to Be Used in Electrochemical Processes. Indian Patent 178184, 18 December 1990. [Google Scholar]
  32. Tsolaki, E.; Pitta, P.; Diamadopoulos, E. Electrochemical disinfection of simulated ballast water using Artemia salina as indicator. Chem. Eng. J. 2010, 156, 305–312. [Google Scholar] [CrossRef]
  33. Annamalai, S.; Sundaram, M.; Curras, M.P. Integrated approach of chemical and electrodialysis process in textile effluent contaminated groundwater for irrigation. J. Environ. Chem. Eng. 2017, 5, 3190–3200. [Google Scholar] [CrossRef]
  34. Crane, S.R.; Moore, J.A. Modeling enteric bacterial die-off: A review. Water Air Soil Pollut. 1986, 27, 411–439. [Google Scholar] [CrossRef]
  35. Deborde, M.; von Gunten, U. Reactions of chlorine with inorganic and organic compounds during water treatment—Kinetics and mechanisms: A critical review. Water Res. 2008, 42, 13–51. [Google Scholar] [CrossRef]
  36. Jeong, J.; Kim, C.; Yoon, J. The effect of electrode material on the generation of oxidants and microbial inactivation in the electrochemical disinfection processes. Water Res. 2009, 43, 895–901. [Google Scholar] [CrossRef] [PubMed]
  37. Liang, W.; Qu, J.; Chen, L.; Liu, H.; Lei, P. Inactivation of Microcystis aeruginosa by continuous electrochemical cycling process in tube using Ti/RuO2 electrodes. Environ. Sci. Technol. 2005, 39, 4633–4639. [Google Scholar] [CrossRef]
  38. Feng, W.; McCarthy, D.T.; Wang, Z.; Zhang, X.; Deletic, A. Stormwater disinfection using electrochemical oxidation: A feasibility investigation. Water Res. 2018, 140, 301–310. [Google Scholar] [CrossRef]
  39. Zanoni, M.V.B.; Sene, J.J.; Selcuk, H.; Anderson, M.A. Photoelectrocatalytic production of active chlorine on nanocrystalline titanium dioxide thin-film electrodes. Environ. Sci. Technol. 2014, 38, 3203–3208. [Google Scholar] [CrossRef]
  40. Heim, C.; Ureña de Vivanco, M.; Rajab, M.; Müller, E.; Letzel, T.; Helmreich, B. Rapid inactivation of waterborne bacteria using boron-doped diamond electrodes. Int. J. Environ. Sci. Technol. 2015, 12, 3061–3070. [Google Scholar] [CrossRef] [Green Version]
Figure 1. SEM (left) and EDS (right) surface mapping analysis of RuO2-TiO2/Ti electrode employed in this study.
Figure 1. SEM (left) and EDS (right) surface mapping analysis of RuO2-TiO2/Ti electrode employed in this study.
Ijerph 19 01835 g001
Figure 2. Effect of current density on E. coli inactivation at (a) 1%, (b) 2%, and (c) 3% NaCl during electrochemical disinfection treatment. Inner graphs show the inactivation during the initial 6 min. Data are given as mean ± standard deviation (n = 3).
Figure 2. Effect of current density on E. coli inactivation at (a) 1%, (b) 2%, and (c) 3% NaCl during electrochemical disinfection treatment. Inner graphs show the inactivation during the initial 6 min. Data are given as mean ± standard deviation (n = 3).
Ijerph 19 01835 g002
Figure 3. First-order kinetics for the inactivation of E. coli at (a) 1%, (b) 2%, and (c) 3% NaCl without applying current. Data are given as mean ± standard deviation (n = 3).
Figure 3. First-order kinetics for the inactivation of E. coli at (a) 1%, (b) 2%, and (c) 3% NaCl without applying current. Data are given as mean ± standard deviation (n = 3).
Ijerph 19 01835 g003
Figure 4. Inactivation performance and concentration of active chlorine during electrochemical disinfection at 0.3 mA/cm2. E. coli was contained in simulated ballast water containing (a) 1%, (b) 2%, and (c) 3% NaCl, respectively. Data are given as mean ± standard deviation (n = 3).
Figure 4. Inactivation performance and concentration of active chlorine during electrochemical disinfection at 0.3 mA/cm2. E. coli was contained in simulated ballast water containing (a) 1%, (b) 2%, and (c) 3% NaCl, respectively. Data are given as mean ± standard deviation (n = 3).
Ijerph 19 01835 g004
Figure 5. pH change of the electrochemical system after 30 min of electrochemical disinfection at various NaCl concentrations and current densities. Data are given as mean ± standard deviation (n = 3).
Figure 5. pH change of the electrochemical system after 30 min of electrochemical disinfection at various NaCl concentrations and current densities. Data are given as mean ± standard deviation (n = 3).
Ijerph 19 01835 g005
Table 1. First-order kinetics of E. coli decay at various NaCl concentrations.
Table 1. First-order kinetics of E. coli decay at various NaCl concentrations.
Current Density, mA/cm2KineticsNaCl conc., % (w/v)
123
0First-order log 10 ( N t N 0 ) = 0.0063 × t log 10 ( N t N 0 ) = 0.0070 × t log 10 ( N t N 0 ) = 0.0087 × t
R2 *0.920.950.96
0.3First-order log 10 ( N t N 0 ) = 0.7076 × t log 10 ( N t N 0 ) = 4.4699 × t log 10 ( N t N 0 ) = 4.8286 × t
R20.790.820.84
* Regression coefficient.
Table 2. Formation of electroactive chlorine species at 30 min of electrolysis.
Table 2. Formation of electroactive chlorine species at 30 min of electrolysis.
NaCl, % (w/v)Current Density, mA/cm2Electroactive Chlorine Species, mg/L
10.317.50 ± 2.25 *
155.83 ± 1.12
2156.34 ± 10.15
3207.39 ± 13.15
20.322.30 ± 2.25
160.62 ± 7.89
2169.11 ± 14.66
3252.06 ± 1.12
30.331.90 ± 5.01
179.76 ± 9.02
2162.72 ± 15.79
3262.35 ± 41.36
* Data are given as mean ± standard deviation (n = 3).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Annamalai, S.; Futalan, C.C.; Ahn, Y. Electrochemical Disinfection of Simulated Ballast Water Using RuO2-TiO2/Ti Electrode. Int. J. Environ. Res. Public Health 2022, 19, 1835. https://doi.org/10.3390/ijerph19031835

AMA Style

Annamalai S, Futalan CC, Ahn Y. Electrochemical Disinfection of Simulated Ballast Water Using RuO2-TiO2/Ti Electrode. International Journal of Environmental Research and Public Health. 2022; 19(3):1835. https://doi.org/10.3390/ijerph19031835

Chicago/Turabian Style

Annamalai, Sivasankar, Cybelle Concepcion Futalan, and Yeonghee Ahn. 2022. "Electrochemical Disinfection of Simulated Ballast Water Using RuO2-TiO2/Ti Electrode" International Journal of Environmental Research and Public Health 19, no. 3: 1835. https://doi.org/10.3390/ijerph19031835

APA Style

Annamalai, S., Futalan, C. C., & Ahn, Y. (2022). Electrochemical Disinfection of Simulated Ballast Water Using RuO2-TiO2/Ti Electrode. International Journal of Environmental Research and Public Health, 19(3), 1835. https://doi.org/10.3390/ijerph19031835

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop