Quantitative Fit Testing on Filtering Facepiece Respirators in Use by Peruvian Healthcare Workers Caring for Tuberculosis Patients during the COVID-19 Pandemic: PROFIT Study 2020
Abstract
:1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Quantitative Fit Testing
2.3. Procedures
2.4. Data Analysis
3. Results
3.1. Description
3.2. Instruction and Real-Time Fit Factor Assessment
3.3. Overall Fit Factor Assessment
4. Discussion
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Azeredo, A.C.V.; Holler, S.R.; de Almeida, E.G.C.; Cionek, O.; Loureiro, M.M.; Freitas, A.A.; Anton, C.; Machado, F.D.; Filho, F.F.D.; Silva, D.R. Tuberculosis in Health Care Workers and the Impact of Implementation of Hospital Infection-Control Measures. Workplace Health Saf. 2020, 68, 519–525. [Google Scholar] [CrossRef] [PubMed]
- Wang, D.; Hu, B.; Hu, C.; Zhu, F.; Liu, X.; Zhang, J.; Wang, B.; Xiang, H.; Cheng, Z.; Xiong, Y.; et al. Clinical Characteristics of 138 Hospitalized Patients with 2019 Novel Coronavirus–Infected Pneumonia in Wuhan, China. Jama 2020, 323, 1061–1069. [Google Scholar] [CrossRef] [PubMed]
- World Health Organization. WHO Guidelines Approved by the Guidelines Review Committee. In Infection Prevention and Control of Epidemic- and Pandemic-Prone Acute Respiratory Infections in Health Care; World Health Organization: Geneva, Switzerland, 2014. [Google Scholar]
- World Health Organization. Infection Prevention and Control during Health Care When Coronavirus Disease (COVID-19) Is Suspected or Confirmed; Overview 2021, WHO/2019-nCoV/IPC/2021.1; World Health Organization: Geneva, Switzerland, 2021. [Google Scholar]
- World Health Organization. WHO Guidelines Approved by the Guidelines Review Committee. In WHO Guidelines on Tuberculosis Infection Prevention and Control: 2019 Update; World Health Organization: Geneva, Switzerland, 2019. [Google Scholar]
- Qian, Y.; Willeke, K.; Grinshpun, S.A.; Donnelly, J.; Coffey, C.C. Performance of N95 respirators: Filtration efficiency for airborne microbial and inert particles. Am. Ind. Hyg. Assoc. J. 1998, 59, 128–132. [Google Scholar] [CrossRef] [PubMed]
- Or, P.; Chung, J.; Wong, T. Does training in performing a fit check enhance N95 respirator efficacy? Workplace Health Saf. 2012, 60, 511–515. [Google Scholar] [CrossRef] [PubMed]
- Cooper, D.W.; Hinds, W.C.; Price, J.M.; Weker, R.; Yee, H.S. Common materials for emergency respiratory protection: Leakage tests with a manikin. Am. Ind. Hyg. Assoc. J. 1983, 44, 720–726. [Google Scholar] [CrossRef] [PubMed]
- Grinshpun, S.A.; Haruta, H.; Eninger, R.M.; Reponen, T.; McKay, R.T.; Lee, S.A. Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: Two pathways for particle penetration. J. Occup. Environ. Hyg. 2009, 6, 593–603. [Google Scholar] [CrossRef] [PubMed]
- Healthcare Respiratory Protection Resources. Available online: https://www.cdc.gov/niosh/npptl/hospresptoolkit/default.html (accessed on 1 June 2022).
- Standard 1910.134: Personal Protective Equipment. Available online: https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.134 (accessed on 1 June 2022).
- Lam, S.C.; Lee, J.K.L.; Yau, S.Y.; Charm, C.Y.C. Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators. J. Hosp. Infect. 2011, 77, 252–256. [Google Scholar] [CrossRef] [PubMed]
- Regli, A.; Sommerfield, A.; von Ungern-Sternberg, B.S. The role of fit testing N95/FFP2/FFP3 masks: A narrative review. Anaesthesia 2021, 76, 91–100. [Google Scholar] [CrossRef]
- Niu, S. ILO list of occupational diseases and health care workers. Afr. Newsl. Occup. Health Saf. 2010, 20, 4–9. [Google Scholar]
- Organización Panamericana de la Salud. Tuberculosis en las Américas. Informe Regional 2019; Organización Panamericana de la Salud: Washington, DC, USA, 2019. [Google Scholar]
- World Health Organization. Global Tuberculosis Report 2020; World Health Organization: Geneva, Switzerland, 2020. [Google Scholar]
- Ley N° 30287 de Prevención y Control de la Tuberculosis en el Perú. Available online: https://www.gob.pe/institucion/minsa/normas-legales/296991-30287 (accessed on 1 June 2022).
- Huaroto, L.; Espinoza, M.M. Recomendaciones para el control de la transmisión de la tuberculosis en los hospitales. Rev. Peru. Med. Exp. Salud Publica 2009, 26, 364–369. [Google Scholar]
- Livingston, E.; Desai, A.; Berkwits, M. Sourcing Personal Protective Equipment During the COVID-19 Pandemic. Jama 2020, 323, 1912–1914. [Google Scholar] [CrossRef] [PubMed]
- Sistema de Información Gerencial de Tuberculosis. Available online: https://appsalud.minsa.gob.pe/sigtbdata/WFLogin.aspx (accessed on 1 June 2022).
- Norma Técnica de Salud para la Atención Integral de las Personas Afectadas por Tuberculosis. Available online: http://www.tuberculosis.minsa.gob.pe/portaldpctb/recursos/20180308083418.pdf (accessed on 1 June 2022).
- To Beard or Not to Beard? That’s a Good Question! Available online: https://blogs.cdc.gov/niosh-science-blog/2017/11/02/noshave/ (accessed on 1 June 2022).
- Fighting Respirator Fraud, Counterfeiting, and Price Gouging. Available online: https://www.3m.com/3M/en_US/worker-health-safety-us/covid19/covid-fraud/ (accessed on 3 June 2022).
- PortaCount Respirator Fit Tester 8048. Available online: https://www.tsi.com/products/respirator-fit-testers/portacount-respirator-fit-tester-8048/ (accessed on 1 June 2022).
- Welker, R.W. Chapter 4—Size Analysis and Identification of Particles. In Developments in Surface Contamination and Cleaning; Kohli, R., Mittal, K.L., Eds.; William Andrew Publishing: Oxford, UK, 2012; pp. 179–213. [Google Scholar]
- Appendix A to § 1910.134—Fit Testing Procedures. Available online: https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.134AppA (accessed on 3 June 2022).
- Proper N95 Respirator Use for Respiratory Protection Preparedness. Available online: https://blogs.cdc.gov/niosh-science-blog/2020/03/16/n95-preparedness/ (accessed on 3 June 2022).
- Brun, D.; Curti, C.; Mekideche, T.; Benech, A.; Hounliasso, I.; Lamy, E.; Castera, C.; Rathelot, P.; Vanelle, P. Stockpiled N95 respirator/surgical mask release beyond manufacturer-designated shelf-life: A French experience. J. Hosp. Infect. 2020, 106, 258–263. [Google Scholar] [CrossRef] [PubMed]
- Chavez-Ruiz, M.; Rueda-Torres, L.; Ruffner-Camargo, B.; Bellido-Achahui, C. Metodología para evaluar el nivel de protección respiratoria de mascarillas y respiradores ante partículas similares a las que transmiten el SARS-CoV-2. Rev. Peru. Med. Exp. Salud Publica 2021, 38, 391–398. [Google Scholar] [CrossRef] [PubMed]
- Voluntary Rescission of Fido Mask Company Certificates of Approvals. Available online: https://www.cdc.gov/niosh/npptl/usernotices/notices/notice08032014.html (accessed on 3 June 2022).
- Non-Compliant Respiratory Protection. Available online: https://www.eu-esf.org/personal-protective-equipment/non-compliant/respiratory-protection/5442-rapex-2020-49-particle-filter-mask-lucca-light-kn95-ffp2 (accessed on 1 June 2022).
- O’Kelly, E.; Arora, A.; Pirog, S.; Ward, J.; Clarkson, P.J. Comparing the fit of N95, KN95, surgical, and cloth face masks and assessing the accuracy of fit checking. PLoS ONE 2021, 16, e0245688. [Google Scholar] [CrossRef] [PubMed]
- Plana, D.; Tian, E.; Cramer, A.K.; Yang, H.; Carmack, M.M.; Sinha, M.S.; Bourgeois, F.T.; Yu, S.H.; Masse, P.; Boyer, J.; et al. Assessing the filtration efficiency and regulatory status of N95s and nontraditional filtering face-piece respirators available during the COVID-19 pandemic. BMC Infect. Dis. 2021, 21, 712. [Google Scholar] [CrossRef] [PubMed]
- Mottay, L.; Le Roux, J.; Perumal, R.; Esmail, A.; Timm, L.; Sivarasu, S.; Dheda, K. KN95 filtering facepiece respirators distributed in South Africa fail safety testing protocols. S. Afr. Med. J. Suid-Afrik. Tydskr. Geneeskd. 2021, 111, 234–239. [Google Scholar] [CrossRef]
- Coffey, C.C.; Lawrence, R.B.; Zhuang, Z.; Duling, M.G.; Campbell, D.L. Errors associated with three methods of assessing respirator fit. J. Occup. Environ. Hyg. 2006, 3, 44–52. [Google Scholar] [CrossRef] [PubMed]
- Bergman, M.; Zhuang, Z.; Brochu, E.; Palmiero, A. Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile. J. Int. Soc. Respir. Prot. 2015, 32, 50–64. [Google Scholar] [PubMed]
- Warning Notice. Available online: http://www.makrite.com/sellers-on-amazon/ (accessed on 1 June 2022).
- Hon, C.Y.; Danyluk, Q.; Bryce, E.; Janssen, B.; Neudorf, M.; Yassi, A.; Shen, H.; Astrakianakis, G. Comparison of qualitative and quantitative fit-testing results for three commonly used respirators in the healthcare sector. J. Occup. Environ. Hyg. 2017, 14, 175–179. [Google Scholar] [CrossRef] [PubMed]
Brand, Model, and Type of FFRs | NIOSH Approval Number | Design of FFR | Batch Number on FFR | Manufacturer | PHC a | n (%) |
---|---|---|---|---|---|---|
3M, 1860, N95 | TC-84A-0006 | Cup/headloop | Yes | 3M, Maplewood, MN, USA | 19 | 87 (33.1) |
Xiantao Zhong Yi, ZYB-11, N95 | TC-84A-7877 | Cup/head loop | Yes | Xiantao Zhongyi Safety Protecting Products Co., Ltd., Xiantao, China | 21 | 65 (24.6) |
Makrite, 9500, N95 | TC-84A-5411 | Cup/headloop | No | Makrite Industries Inc., Taipei, Taiwan | 17 | 54 (20.5) |
3M, 9010, N95 | TC-84A-4243 | Folding/headloop | Yes | 3M, Maplewood, MN, USA | 12 | 19 (7.2) |
3M, 9920H, PFF | - | Folding/head loop | Yes | 3M, Sao Paulo, Brasil | 3 | 11 (4.2) |
Grande, CDN3S-P2, FFP2 | - | Cup/head loop | No | Jiangyin Chang-hung Industrial, JiangYin, China | 8 | 11 (4.2) |
PGT Care, PGT-0095, FFP2 | - | Folding/earloop | No | Fujian Dahong Industry & Development Co., Ltd., Shishi, China | 3 | 6 (2.3) |
Brand and model unknown, KN95 b | - | Folding/earloop | No | Unknown, China | 5 | 6 (2.3) |
Giko, 1200H, N95 | TC-84A-4006 | Cup/head loop | No | Shanghai Gangkai Purifying Products Co., Ltd., Shanghai, China | 1 | 1 (0.4) |
Benehal, MS6115L, N95 | TC-84A-8474 | Cup/head loop | Yes | Suzhou Sanical Protective Product Manufacturing Co., Ltd., Suzhou, China | 1 | 1 (0.4) |
Y&Z, Safety Work F720, N95 | TC-84A-4227 | Cup/head loop | No | Fido Mask Co., Ltd., Taichung, Taiwan | 1 | 1 (0.4) |
Lucca Light, Lucca Care, KN95/FFP2 | - | Folding/earloop | No | Unknown, China | 1 | 1 (0.4) |
Total | 263 |
Brand, Model, and Type of FFRs | rt-FF Pre-Instruction, n = 184 | rt-FF Post-Instruction, n = 184 | n (%) | ||||||
---|---|---|---|---|---|---|---|---|---|
<50 | 50–99 | ≥100 | Geometric Mean (IC 95%) | <50 | 50–99 | ≥100 | Geometric Mean (IC 95%) | ||
n (%) | n (%) | n (%) | n (%) | n (%) | n (%) | ||||
3M, 1860, N95 | 19 (40.4) | 10 (21.3) | 18 (38.3) | 42.2 (27.5–64.5) | 1 (2.1) | 2 (4.3) | 44 (93.6) | 168.7 (141.4–201.5) | 47 (25.5) |
Xiantao Zhong Yi, ZYB-11, N95 | 34 (94.4) | 2 (5.6) | - | 8.0 (5.6–11.3) | 25 (69.4) | 10 (27.8) | 1 (2.8) | 29.0 (21.0–40.0) | 36 (19.6) |
Makrite, 9500, N95 | 46 (97.9) | 1 (2.1) | - | 4.0 (2.9–5.6) | 33 (70.2) | 10 (21.3) | 4 (8.5) | 24.6 (18.1–33.4) | 47 (25.5) |
3M, 9010, N95 | 14 (77.8) | 3 (16.7) | 1 (5.6) | 7.22 (3.1–16.9) | 3 (16.7) | 4 (22.2) | 11 (61.1) | 98.0 (61.1–157.2) | 18 (9.8) |
3M, 9920H, PFF | 9 (81.8) | 1 (9.1) | 1 (9.1) | 12.7 (6.2–26.1) | 4 (36.4) | 1 (9.1) | 6 (54.5) | 62.3 (27.3–142.2) | 11 (6.0) |
Grande, CDN3S-P2, FFP2 | 10 (90.9) | - | 1 (9.1) | 6.5 (2.5–16.8) | 6 (54.5) | 2 (18.2) | 3 (27.3) | 22.8 (6.8–76.5) | 11 (6.0) |
PGT Care, PGT-0095, FFP2 | 6 (100) | - | - | 7.6 (2.2–25.7) | 3 (50.0) | - | 3 (50.0) | 53.5 (13.0–220.8) | 6 (3.3) |
Brand and model unknown, KN95 a | 5 (100) | - | - | 2.6 (0.7–9.3) | 5 (100) | - | - | 13.7 (4.4–42.2) | 5 (2.7) |
Giko, 1200H, N95 | 1 (100) | - | - | - | 1 (100) | - | - | - | 1 (0.5) |
Y&Z, Safety Work F720, N95 | 1 (100) | - | - | - | 1 (100) | - | - | - | 1 (0.5) |
Lucca Light, Lucca Care, KN95/FFP2 | 1 (100) | - | - | - | 1 (100) | - | - | - | 1 (0.5) |
Total | 146 (79.4) | 17 (9.2) | 21 (11.4) | 9.7 (7.8–12.2) | 83 (45.1) | 29 (15.8) | 72 (39.1) | 49.1 (40.5–59.6) | 184 |
Brand, Model, and Type of FFRs | Hours of FFRs Use a | Overall-FF, n = 263 | n (%) | |||
---|---|---|---|---|---|---|
<50 | 50–99 | ≥100 | Geometric Mean (IC 95%) | |||
n (%) | n (%) | n (%) | ||||
3M, 1860, N95 | 12 (19) | 9 (10.3) | 5 (5.8) | 73 (83.9) | 126.0 (109.4–146.6) | 87 (33.1) |
Xiantao Zhong Yi, ZYB-11, N95 | 12 (26) | 58 (89.2) | 6 (9.3) | 1 (1.5) | 15.1 (11.7–19.4) | 65 (24.6) |
Makrite, 9500, N95 | 6 (14) | 47 (87.0) | 7 (13.0) | - | 12.4 (9.1–17.0) | 54 (20.5) |
3M, 9010, N95 | 5.5 (16) | 7 (36.8) | 5 (26.4) | 7 (36.8) | 44.9 (22.7–88.9) | 19 (7.2) |
3M, 9920H, PFF | 18 (20) | 6 (54.5) | 2 (18.2) | 3 (27.3) | 34.1 (11.2–103.5) | 11 (4.2) |
Grande, CDN3S-P2, FFP2 | 12 (20) | 9 (81.8) | - | 2 (18.2) | 13.8 (5.0–37.7) | 11 (4.2) |
PGT Care, PGT-0095, FFP2 | 3 (15) | 4 (66.3) | 1 (16.7) | 1 (16.7) | 21.0 (4.6–96.0) | 6 (2.3) |
Brand and model unknown, KN95 b | 6 (9) | 6 (100) | - | - | 2.8 (1.1–7.4) | 6 (2.3) |
Giko, 1200H, N95 | 6 | 1 (100) | - | - | - | 1 (0.4) |
Benehal, MS6115L, N95 | 3 | - | 1 (100) | - | - | 1 (0.4) |
Y&Z, Safety Work F720, N95 | 3 | 1 (100) | - | - | - | 1 (0.4) |
Lucca Light, Lucca Care, KN95/FFP2 | - | 1 (100) | - | - | - | 1 (0.4) |
Total | 12 (18) | 149 (56.6) | 27 (10.3) | 87 (33.1) | 31.5 (26.3–37.8) | 263 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Inolopú, J.; Mayma, K.; Curisinche-Rojas, M.; Aylas, R.; Flores, J.A.; Rosales-Rimache, J. Quantitative Fit Testing on Filtering Facepiece Respirators in Use by Peruvian Healthcare Workers Caring for Tuberculosis Patients during the COVID-19 Pandemic: PROFIT Study 2020. Int. J. Environ. Res. Public Health 2023, 20, 6618. https://doi.org/10.3390/ijerph20166618
Inolopú J, Mayma K, Curisinche-Rojas M, Aylas R, Flores JA, Rosales-Rimache J. Quantitative Fit Testing on Filtering Facepiece Respirators in Use by Peruvian Healthcare Workers Caring for Tuberculosis Patients during the COVID-19 Pandemic: PROFIT Study 2020. International Journal of Environmental Research and Public Health. 2023; 20(16):6618. https://doi.org/10.3390/ijerph20166618
Chicago/Turabian StyleInolopú, Jorge, Kevin Mayma, Maricela Curisinche-Rojas, Rula Aylas, Juan A. Flores, and Jaime Rosales-Rimache. 2023. "Quantitative Fit Testing on Filtering Facepiece Respirators in Use by Peruvian Healthcare Workers Caring for Tuberculosis Patients during the COVID-19 Pandemic: PROFIT Study 2020" International Journal of Environmental Research and Public Health 20, no. 16: 6618. https://doi.org/10.3390/ijerph20166618
APA StyleInolopú, J., Mayma, K., Curisinche-Rojas, M., Aylas, R., Flores, J. A., & Rosales-Rimache, J. (2023). Quantitative Fit Testing on Filtering Facepiece Respirators in Use by Peruvian Healthcare Workers Caring for Tuberculosis Patients during the COVID-19 Pandemic: PROFIT Study 2020. International Journal of Environmental Research and Public Health, 20(16), 6618. https://doi.org/10.3390/ijerph20166618