Next Article in Journal
Symmetrical Cascaded Switched-Capacitor Multilevel Inverter Based on Hybrid Pulse Width Modulation
Previous Article in Journal
Process Efficiency and Energy Consumption during the Ultrasound-Assisted Extraction of Bioactive Substances from Hawthorn Berries
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Integrated Capacitive Deionization and Humidification-Dehumidification System for Brackish Water Desalination

by
Sadam-Hussain Soomro
1,
Yusufu Abeid Chande Jande
2,3,
Salman Memon
4,
Woo-Seung Kim
5 and
Young-Deuk Kim
5,6,*
1
Department of Mechanical Convergence Engineering, Hanyang University School of Mechanical Engineering, 222 Wangsimni-ro, Seongdong-gu, Seoul 04763, Korea
2
Department of Materials and Energy Sciences and Engineering, The Nelson Mandela African Institution of Science and Technology, Arusha P.O. Box 447, Tanzania
3
Water Infrastructure and Sustainable Energy Futures (WISE-Futures) Center, The Nelson Mandela African Institution of Science and Technology, The Nelson Mandela Road, Arusha P.O. Box 447, Tanzania
4
Department of Mechanical Design Engineering, Hanyang University, 55 Hanyangdaehak-ro, Sangnok-gu, Ansan 15588, Gyeonggi-do, Korea
5
Department of Mechanical Engineering, Hanyang University, 55 Hanyangdaehak-ro, Sangnok-gu, Ansan 15588, Gyeonggi-do, Korea
6
BK21 FOUR ERICA-ACE Center, Hanyang University, 55 Hanyangdaehak-ro, Sangnok-gu, Ansan 15588, Gyeonggi-do, Korea
*
Author to whom correspondence should be addressed.
Energies 2021, 14(22), 7641; https://doi.org/10.3390/en14227641
Submission received: 11 October 2021 / Revised: 9 November 2021 / Accepted: 10 November 2021 / Published: 15 November 2021
(This article belongs to the Section B: Energy and Environment)

Abstract

:
A hybrid capacitive deionization and humidification-dehumidification (CDI–HDH) desalination system is theoretically investigated for the desalination of brackish water. The CDI system works with two basic operations: adsorption and regeneration. During adsorption, water is desalted, and during the regeneration process the ions from electrodes are detached and flow out as wastewater, which is higher in salt concentration. This wastewater still contains water but cannot be treated again via the CDI unit because CDI cannot treat higher-salinity waters. The discarding of wastewater from CDI is not a good option, since every drop of water is precious. Therefore, CDI wastewater is treated using waste heat in a process that is less sensitive to high salt concentrations, such as humidification-dehumidification (HDH) desalination. Therefore, in this study, CDI wastewater was treated using the HDH system. Using the combined system (CDI–HDH), this study theoretically investigated brackish water of various salt concentrations and flow rates at the CDI inlet. A maximum distillate of 1079 L/day was achieved from the combined system and the highest recovery rate achieved was 24.90% from the HDH unit. Additionally, two renewable energy sources with novel ideas are recommended to power the CDI–HDH system.

Graphical Abstract

1. Introduction

Earth’s quantity of freshwater—one of the vital components for life—is shrinking every day, and the situation is further exacerbated by rapid population growth. The prediction in [1] revealed that by 2040, two-thirds of the world’s population will suffer from a dearth of freshwater. Although the surface of the Earth is 70% water, 97% of that resides in oceans, which have a much higher salt concentration. The salinity of seawater is very high, containing dissolved salts ranging from 10,000 to 35,000 parts per million (ppm). Additionally, the sea contains many impurities like industrial waste materials, domestic waste, mortal remains, sewage waste, etc. Of the remaining 3% of the water on Earth, the majority (77%) is frozen water trapped in glaciers, 1% is in lakes and rivers, and 22% is groundwater. The problem is increasingly serious because the groundwater is also becoming salty due to agricultural chemicals, septic waste, landfill, road salts, underground pipes, hazardous waste, etc., which result in the dissolution of minerals such as anhydrite, carbonates, gypsum, fluoride salts, etc., into groundwater. Therefore, seawater and polluted groundwater are unfit for domestic and industrial use. Water that has a salinity of less than 500 ppm is considered to be freshwater [2,3]. To cope with the soaring demand for freshwater, the only choice for producing freshwater is to remove excess salt from seawater and/or brackish water using desalination techniques. Desalination processes such as forward osmosis (FO) and reverse osmosis (RO) require pressure energy to permit the water to flow through the membrane. Multi-stage flash (MSF), multi-effect distillation (MED), solar still (SS), humidification-dehumidification (HDH), and membrane distillation (MD) include phase change and require thermal energy. Capacitive deionization (CDI) and electrodialysis are performed using electrical energy.
In addition to the technologies described above, a hybrid desalination system may be considered. A hybrid desalination system combines two or more technologies. The hybrid system can have more benefits such as higher productivity, energy savings, higher efficiency, and maximizing the overall recovery. Several hybrid desalination systems have been developed during the last few decades and offer promising and improved performance.
Leon et al. [4] integrated RO with an MSF unit, which provided the benefit of blending the products of these two systems. This results in the operation of RO units with higher total dissolved salts (TDS) and consequently lowers the replacements of membranes and reduces cost by nearly 40%. A hybrid process termed “MEDAD” desalination, which is the combination of MED and adsorption cycle (AD), was proposed by Shahzad et al. [5]. Their combination allowed MED stages to run at a lower ambient temperature (about 5 °C) compared to the conventional multi-effect distillation (MED) system. The hybrid MEDAD increased productivity from 2.5-fold to 3-fold as compared to MED at the same top brine condition. An HDH desalination system coupled with a heat pump working on a vapor compression cycle was proposed by Lawal et al. [6]. They conducted an experimental and theoretical study of a system working with an open-water and open-air circulation mode. Their system produced a maximum GOR of 2.72, with a recovery ratio of 2.56%. Meanwhile, the distillate rate from the system was 9.23 kg/h with a unit cost of 15.14 USD/m3.
Emad et al. [7] combined the MD and RO units in series for desalting geothermal brackish water. Brine from the MD unit was fed into the RO unit and recycled again to the MD unit. The recycling was found to be highly effective and maximized the freshwater production rate, increased the recovery rate, and reduced the specific energy consumption. The overall recovery rate in the hybrid MD–RO model increased to 40% with an energy cost of 0.9 USD/m3. The energy cost per cubic meter of water produced was USD 0.9. A VMD (vacuum membrane distillation)–RO hybrid system, where VMD was the complimentary process to the RO unit in order to concentrate the RO brines further, was proposed by Mericq et al. [8]. Their hybrid system showed a rise in the recovery of the unit. Lawal and Antar [9] investigated an HDH desalination system coupled with a heat pump. They compared three configurations (A, B, and C) in their system. In A, seawater is heated in a brine heat exchanger (HX) after leaving the dehumidifier; in B, air is heated in an HX after leaving the humidifier; while in C, no HX was employed. Their system produced a recovery of 23.3%, 23.1%, and 15.23% with configurations C, B, and A, respectively.
Alessandra and Enrico [10] integrated RO with the MD desalination system and performed an energy and exergy analysis of the hybrid system. In their configuration the brine from RO was treated inside the MD unit. The Nano filtration (NF) process was utilized to pretreat the feed prior to using the RO unit. The authors revealed that the proposed system is an alternative to RO and also to thermal desalination techniques. Tabrizi et al. [11] performed an experimental analysis of a cascade solar still (SS) with HDH desalination for the weather conditions of Zahedan, Iran. The daily production of the SS with and without HDH were obtained for different mass flow rates, and it was concluded that the daily production rate increased from 28% to 141% and the thermal efficiency increased from 9% to 20% in the presence of the HDH system. A hybrid MSF–HDH desalination unit for energy recovery was studied by Lawal et al. [12]. The MSF–HDH unit increased the overall productivity and performance ratio and reduced brine rejection. Four different configurations of the MSF–HDH unit were proposed and compared. They revealed that the HDH system could use over 66% of an existing MSF brine. Additionally, the MSF–HDH unit had water recovery, productivity, a freshwater cost, and a gained output ratio (GOR) of 44.86%, 30,549 m3/day, 1.068 USD/m3, and 8.73, respectively. An HDH system for desalination and space conditioning was investigated by Lawal et al. [13]. In their system feed water was heated using heat energy from a condenser and at the same time cooling water was cooled further inside the evaporator of the heat pump before it entered the dehumidifier. The air leaving the dehumidifier was traveling to the room for space conditioning. They revealed that the integrated system attained a GOR of 4.07 and the amount of water produced was 287.8 L/day. Additionally, the recovery ratio of the system was 4.86%. The minimum specific energy consumption was 160.16 kWh/m3.
Another hybrid system, MD–HDH for zero liquid discharge (ZLD) for inland desalination was proposed by Matar et al. [14]. They found that HDH was effective in the generation of solids from the brine of the MD unit. A 40% recovery rate was produced by the MD producing the freshwater with TDS < 20 mg/L for a flux of 5 L/m2/h. HDH produced additional freshwater with TDS < 100 mg/L. The energy required for the HDH and MD were 220 kWh/m3 and 260 kWh/m3, respectively.
The above literature showed that the integration of two or more desalination technologies had some additional benefits compared to a single desalting unit. Similarly, the hybrid CDI–HDH desalination system was proposed in this system and its explanation is as follows.
Capacitive deionization (CDI) is an advanced method for brackish/groundwater desalination in which water flows between a pair of biased/polarized electrodes. The anions and cations are attracted to the positive and negative electrodes, respectively. In CDI there are two modes of operation: ion adsorption and regeneration. During adsorption, the ions are removed from (treatable) feed water and attached to the electrodes. Regeneration is the reverse of the adsorption process: when the electrodes are saturated, the ions are removed from electrodes by reversing the current or making zero voltage. The water carries away ions during the regeneration mode and rejects it as wastewater, which is higher in salt concentration but still contains water. Treating wastewater is better than discarding it because every drop of water is highly precious. The drawbacks of the CDI process are: it cannot remove bacteria, viruses, or other poisoning materials such as boric acid (dangerous to human health and can cause nausea, vomiting, stomach aches, and diarrhea); and it cannot proceed with high-salinity water. The wastewater that leaves CDI cannot be re-treated using CDI. Proof of this is further explained in detail in Section 3.
Therefore, wastewater discarded from CDI can be treated in HDH desalination because of its ability to deal with water with a high salt concentration. HDH desalination is an emerging option in the desalination field, particularly for small-scale systems. HDH desalination technology mimics the rain cycle: in a humidifier, either air or water is heated; hot water is sprayed inside the evaporator (humidifier) over packing material; and air flows against the water flow and transports the water vapor at the expense of the heat of the water, leaving behind high-density salts. This hot, humid air is transferred to a dehumidifier, where cold water makes contact with the air and condenses it, thereby producing pure water. HDH desalination technology offers many advantages compared with other methods: it enables a stable and simple control system, does not require strict pretreatment, poses no scaling problem, enables operation at atmospheric pressure, is low maintenance, and has no sensitivity to water with a high salt concentration [15]. One of the major benefits of the HDH system is that it can be operated using any low-grade waste heat [16].
In this study, brackish water was treated inside the CDI unit, and wastewater leaving the CDI unit was further treated in the HDH desalination unit in order to recover more distillate water. Therefore, a theoretical study was carried out using the mathematical model of CDI and HDH desalination systems.

2. System Description

2.1. CDI System

The CDI process involves the two main modes (adsorption and regeneration), as shown in Figure 1. In the following study, the CDI unit contains two stacks. If one stack is under regeneration, then the other stack performs purification [17], as shown in Figure 2.

2.2. CDI Model

The model developed by Jande and Kim [18] was used to compute the CDI system, and the CDI system was operated at a constant current. In this study, each stack contained 500 pairs of electrodes; each pair was assumed to have a capacitance Ca of 8000 F (a reasonable amount for most activated carbon materials with a specific capacitance of at least 80 F/g, and 100 g is spread over 1 m2). The current I to be used for water desalination for the specified CDI stack is expressed as shown in Equation (1), where z is the average valence (for this study, only NaCl was being considered); Cf is the feed water concentration in mol/m3; F is the Faraday constant (96,540 C/mol); Φ is the feedwater flow rate to the CDI electrode pair; and λ is the charge efficiency (assumed as one in this study, i.e., assuming that good materials or ion exchange membranes are used [17]).
I = z C f F Φ λ
The CDI system under a constant current was charged for a duration tc based on Equation (2), where Vt is the target voltage (which was 1.5 V for this study).
t c = C a V t I
During the charging time (water purification period by CDI), the amount of energy, E, stored for the entire stack is expressed as shown in Equation (3), where Ca is the capacitance and n is the number of electrode pairs for the stack, which was 500 for this study. For a CDI system, 83% of the stored energy can be recovered and used to operate the plant [17]. Therefore, only 17% of the stored energy was considered in this study as the energy used by the CDI system to produce freshwater.
E = 1 2 n C a V t 2
The total amount of freshwater produced during charging for the entire CDI stack cycle is the product of the flow rate to the system and the time used to charge the CDI stack. In this study, the charging time was considered to be equal to the discharging time; this implies that the cycle time for the CDI stack operation is twice the water purification time. It is important to note the specific energy consumption expressed in units of kWh/m3, which implies the ratio of the energy used to produce fresh water to the amount of water produced, in the cycle time of the CDI operation. In this study, the spacer volume and dead volume were set as 20 mL.
The brine concentration (effluent concentration during discharging, Cefd) of the CDI electrode pair during constant-current discharging is constant, and it can be computed by determining the concentration at time t = tc using Equation (4) as described in [18], where Vc is the dead volume. The brine salt concentration for the CDI stack is the same as the concentration from the electrode pair; however, the flow rate of the brine from the CDI stack is ϕ = nΦ (which is equal to the flow rate during charging, where Φ is the flow rate to each pair of electrodes). The CDI stack wastewater with this concentration and flow rate is fed to the HDH system for purification, as will be described in the next section.
C e f d t = C f + λ I z F Φ 1 e Φ V c t

2.3. HDH System

The principle of the HDH system is simple: water evaporates inside the humidifier and the generated humid air is condensed inside the dehumidifier. The proposed HDH system is composed primarily of a humidifier, dehumidifier, and water heater. In the humidifier, the air is humidified through direct contact with the hot, salty water which is sprayed over the packing materials inside the humidifier; subsequently, the hot and humid air enters the dehumidifier and establishes contact with cold surfaces. The dehumidifier is a fin tube heat exchanger in which inlet water flows through tubes and air passes over fins. This causes the water vapor to condense from the air, thereby resulting in the production of distillate at the bottom of the dehumidifier. Air releases the enthalpy of condensation, which is recuperated and used to preheat the inlet water before it enters the heater. The water leaving the dehumidifier is then further heated up to the desired temperature. The air leaving the dehumidifier enters the humidifier for the next cycle. Meanwhile, the water leaving the humidifier has a higher salt concentration and is described as HDH brine.

2.4. HDH Model

The thermodynamic model for a water-heated HDH system, as shown in Figure 3, is based on the energy and mass balance principle, and the following assumptions are considered:
  • The system is in a steady state;
  • Heat losses to the surroundings and conduction losses are disregarded;
  • Kinetic and potential energy terms are disregarded;
  • Pressure losses are disregarded;
  • Pumping and fan powers are disregarded;
  • Air is assumed to have 90% relative humidity at the humidifier and dehumidifier outlets [19];
  • Humidifier outlet air and dehumidifier inlet air temperatures are assumed to be the same; similarly, the humidifier inlet air and dehumidifier outlet air temperatures are assumed to be the same [19];
  • The water temperature at the dehumidifier inlet is assumed to be 25 °C;
  • The effectiveness of the humidifier and dehumidifier was fixed at 85%.
Figure 3. HDH desalination unit.
Figure 3. HDH desalination unit.
Energies 14 07641 g003

2.4.1. Humidifier

The energy balance equation for the humidifier is expressed as follows:
m ˙ w H w 3 + m ˙ a H a 5 = m ˙ b H w 4 + m ˙ a H a 6
where m ˙ w , m ˙ a , and m ˙ b are the mass flow rates of water, air, and brine, respectively; Hw3 and Hw4 are the enthalpies of water entering the humidifier and brine leaving the humidifier, respectively; and Ha5 and Ha6 are the enthalpies of air entering and leaving the humidifier, respectively; and m ˙ b can be expressed as follows:
  m ˙ b = m ˙ w m ˙ a ω 6 ω 5
Equation (5) can be written as:
m ˙ w H w 3 + m ˙ a H a 5 = [ m ˙ w m ˙ a ω 6 ω 5 ] H w 4 + m ˙ a H a 6
where ω6 and ω5 are the absolute humidity of air at the humidifier and dehumidifier outlet, respectively.
The effectiveness of the humidifier is expressed as [19]:
ε h = max [ H a 6 H a 5 H a 6 , i d e a l H a 5 , H w 3 H w 4 H w 3 H w 4 , i d e a l ]
where Ha6,ideal is the outlet air enthalpy measured at the temperature of the water at the humidifier inlet, and Hw4,ideal is the ideal enthalpy of the water measured at the temperature of the air at the humidifier inlet [20].

2.4.2. Dehumidifier

The energy balance in the dehumidifier is expressed as follows:
m ˙ w H w 1 + m ˙ a H a 6 = m ˙ w H w 2 + m ˙ a H a 5 + m ˙ d H d
where Hw1 is the enthalpy of the water entering the dehumidifier; Hw2 is the enthalpy of the water leaving the dehumidifier; and Hd is the enthalpy of the distillate at temperature Td, which was set as the average of the air temperature at the inlet and outlet of the dehumidifier.
The distillate flow rate m ˙ d is defined as follows:
m ˙ d = m ˙ a ω 6 ω 5
Equation (9) can be written as:
m ˙ w H w 1 + m ˙ a H a 6 = m ˙ w H w 2 + m ˙ a H a 5 + [ m ˙ a ω 6 ω 5 ] H d
where ω6 and ω5 are the humidity ratios of air at the dehumidifier inlet and outlet, respectively.
The effectiveness of the dehumidifier is expressed as [19]:
ε d = max [ H a 6 H a 5 H a 6 H a 5 , i d e a l , H w 2 H w 1 H w 2 , i d e a l H w 1 ] ,  
where Ha5,ideal is the ideal enthalpy of air calculated at the temperature of the water at the dehumidifier inlet, and Hw2,ideal is the ideal enthalpy of water calculated at the temperature of the air at the dehumidifier inlet [20].
The enthalpy of saltwater is calculated as follows [21]:
H w = H p w S a 1 + a 2 S + a 3 S 2 + a 4 S 3 + a 5 T + a 6 T 2 + a 7 T 3 + a 8 S T + a 9 S 2 T + a 10 S T 2 ,  
where S is the salt concentration, and the coefficients used in the equation above are listed in Table 1. Hpw is the enthalpy of salt-free water, which is expressed as [21]:
H p w = 141.355 + 4202.07 T 0.535 T 2 + 0.004 T 3
The enthalpy of moist air is expressed as [22]:
H a = c p a + c p v ω T + h f g ω
where cpa and cpv are the specific heat capacities of air and vapor, respectively, and hfg is the enthalpy of vaporization of water, whose expression over a temperature range of 5–200 °C is [23]:
h f g = 2501.897149 2.407064037 T + 1.192217 × 10 3 T 2 1.5863 × 10 5 T 3
The humidity ratio is calculated as follows [24]:
ω = 0.6219 [ ψ P s P a t m ψ P s ]
where ψ is the relative humidity, Patm is the atmospheric pressure, and Ps is the saturation pressure [25] expressed as:
P s = 2.7 × 10 9 T 5 + 2.8 × 10 7 T 4 + 2.7 × 10 5 T 3 + 0.0014 T 2 + 0.044 T + 0.61

2.4.3. Heater

The preheater is added to heat the water before the humidifier between points 2 and 3; therefore, a model for the input thermal energy is necessitated and is given as follows:
Q ˙ i n = m ˙ w c p w T 3 T 2 ,  
where Q ˙ i n is the heat transfer rate required to raise the temperature of water from T2 to T3. The preheater energy may be provided by solar collectors, other forms of renewable energy, a process heating steam, a diesel engine, or low-grade energy available in industrial sites. The highly recommended option for supplying electricity and heat simultaneously to both the CDI and HDH units is further explained in Section 3.1.
The specific thermal energy consumption (STEC) is defined as follows [26]:
S T E C = Q ˙ i n ρ 3600 m ˙ d
where ρ is water density.
The recovery ratio (RR) is defined as the ratio of the distillate flow rate to the water flow rate, as follows [27]:
R R = m ˙ d m ˙ w
Mass ratio is an important parameter in HDH desalination systems and is defined as follows:
M R = m ˙ w m ˙ a  
The salinity of the brine at the humidifier exit can be expressed in terms of the RR as follows:
S o u t = S i n 1 R R
where Sin is the salinity of the water at the humidifier inlet. The thermal performance of the HDH system is described in terms of the gained output ratio (GOR) which is calculated as follows [24]:
G O R = m ˙ d h fg Q ˙ i n
where hfg is the latent heat of the vaporization of water.
The objective of the HDH model is to predict the system performance, which is expressed in terms of the distilled water flow rate, recovery ratio, and energy required. The evaluation of the distilled water flow rate requires the calculation of temperatures T5 and T6; the recovery ratio can be calculated after determining the distillate rate. To determine the energy required, temperature T2 must be calculated, as shown in Equation (19). Therefore, the unknowns are T2, T4, T5, T6, and Q ˙ i n , and the five associated equations are Equations (7), (8), (11), (12) and (19). The equations are nonlinear and were solved using the Newton–Raphson method, and the code was built using MATLAB software. The known parameters were air and water flow rates, inlet salinities and temperatures at the dehumidifier and humidifier, the effectiveness of the humidifier and dehumidifier, the relative humidity of the air, and the specific heat capacities of water and air.

2.5. CDI–HDH System

The schematic illustration presented in Figure 4 shows the hybrid CDI–HDH system. The system comprises a CDI unit, buffer tank, and HDH unit. The brackish water enters the CDI unit and is treated to extract freshwater. After treatment, the CDI brine is stored in a buffer and subsequently fed into a water-heated HDH unit at room temperature for further treatment.

3. Results and Discussion

Five different cases of CDI inlet feed flow rates and salinities were considered for analysis, as shown in Table 2. The salinities of feedwater at the inlet were selected considering the fact that brackish water salinity ranges from 1500 to 15,000 ppm [28]. For each case of the CDI unit, the productivity, cycle time, purity of distilled water, and energy consumption were determined, as shown in Table 3.
The results in Table 3 illustrate the reason that CDI cannot work with higher feed concentrations: an increase in the feedwater salinity increases the specific energy consumption (SEC), reduces the distillate water purity, and reduces the production of distillate. In Case 1, when the highest feed salinity is considered, i.e., 11,038 ppm, the energy consumption is also highest at 0.65 kWh/m3 and the purity of the distilled water is also reduced; in other words, the salinity of the distillate water is increased. Additionally, the amount of water produced is lower, at 329.4 L per cycle.
As the salinity decreased in Cases 2, 3, and 4, it can be seen that the SEC also decreased to 0.51, 0.49, and 0.47 kWh/m3, respectively; the purity of the distilled water increased to 210, 191, and 181 ppm, respectively; and the amount of water produced increased to 416.5, 436.4 and 448.4 L per cycle, respectively. For Case 5, when the salinity was again increased, the results showed that the SEC increased to 0.58 kWh/m3, the purity decreased to 271 ppm, and the amount of water produced was 366 L. It can also be seen that an increase in the feedwater salinity increases the salinity of the wastewater and distillate; therefore, CDI operation at higher salinities is not favorable because it will not produce distillate within a potable range.
The wastewater from the CDI unit had a higher salinity that was beyond the operating limit of CDI [29] and therefore this wastewater was treated inside the HDH desalination unit. The wastewater leaving the CDI unit during the regeneration process is fed into the HDH unit at a dehumidifier inlet at room temperature at 25 °C. Since the mass flow rate of wastewater cannot be changed in the HDH, the only parameters that can be altered inside the HDH unit are mass ratio (MR), which is the ratio of water mass flow rate to the air mass flow rate defined by Equation (22), and the humidifier inlet water temperature T3, which is the wastewater temperature at the humidifier inlet. To evaluate the system performance of the HDH unit, the mass ratios (MRs) from one to six were considered. This range was considered in order to find out the optimal MR, keeping in mind that the MR should be more than or equal to one for balanced conditions [30]. The air flow rate in the MR was changing but the feed water flow rate was kept constant. The humidifier inlet water temperature T3 was selected to be 50–80 °C because this operating range is preferred, provided that a heat source is available and materials are durable [31].
The effect of the MR on HDH performance was investigated. The MR was set from one to six, and the distillate production rate from the HDH unit vs. the MR is shown in Figure 5. The results showed that the distillate production rate for all cases of wastewater increased with an increase in the MR up to three, and the distillate production rate decreased after that with a further increase in the MR. This is because for an MR of three, the contact time between the air and water increases, and the air carries away more moisture from the humidifier, but the larger the MR, the shorter the residence time, and the air is discharged from the humidifier without getting enough moisture. The productivity was the lowest at an MR of six in all cases.
Figure 6 shows that at MR = 3, the salinity of the HDH brine was higher at higher flow rates (Case 1) because higher evaporation occurred at this MR, leading to more concentrated brine exiting the humidifier, while at a higher MR less evaporation occurred, which results in brine exiting with a lower salt concentration.
Figure 7 shows the variation in the moisture content (humidity ratio of the air) with an increase in the MR for all five cases. The results indicated that the humidity ratio of the air across the humidifier outlet was highest in Case 5 with an MR of three and lowest in Case 1 with an MR of six.
The effect of the humidifier inlet water temperature on the specific thermal energy consumption rate (STEC) is depicted in Figure 8. It can be seen that at higher values of T3 energy consumption was lower while at lower values of T3 the STEC was very high.
The effect of the humidifier inlet water temperature T3 on the distillate production rate is shown in Figure 9. It can be seen that the highest distillate production rate (3.83 kg/h) was recorded at the higher humidifier inlet water temperature and higher CDI brine flow rate at the dehumidifier, i.e., 80 °C and 0.0227 kg/s, respectively. This is because at a higher humidifier inlet water temperature, the evaporation rate is also higher. At a higher feedwater flow rate (0.0227 kg/s), the distillate production rate also increases because the surface temperature of the dehumidifier is reduced and causes more condensation, which in turn collects more distillate at the dehumidifier bottom.
Figure 10 shows the effect of humidifier inlet water temperature on outlet brine salinity from HDH. It was observed that at higher humidifier inlet water temperatures the brine salinities were also higher. This is because at a higher humidifier inlet water temperature, evaporation is higher, and this leads to more concentrated brine exiting the humidifier. At 80 °C, the salinity of the HDH brine was higher, with a concentration of about 30,000 ppm. Figure 11 shows the effect of the humidifier inlet water temperature on the recovery ratio (RR) from HDH. It was observed that at higher humidifier inlet water temperatures the RR was higher. This is because at higher humidifier inlet water temperatures, the distillate production rate was also higher. The RR was 3.92%, 7.54%, 13.71%, and 24.90% at 50 °C, 60 °C, 70 °C, and 80 °C, respectively, for a wastewater salinity of 22,078 ppm.
The combined distillate production rate of the CDI–HDH system per day for all cases is shown in Figure 12. The highest production rate was approximately 1079 L/day for Case 5 ( m ˙ s w = 0.0227 kg/s, feed salinity 19,867 ppm), and the lowest rate was approximately 697 L/day for Case 1 (   m ˙ s w = 0.0147 kg/s, feed salinity 22,078 ppm). The results shown in Figure 11 were obtained based on the following HDH conditions: MR = 3.0; component effectiveness = 80%; humidifier inlet water temperature = 80 °C.
Figure 13 demonstrates the results of the present HDH model and that of Narayen et al. [30]. The variation of the GOR (defined by Equation (24)) versus the MR for the humidifier effectiveness (εh) of the different systems was determined. The MR is the ratio of the seawater mass flow rate to the air mass flow rate. The operating conditions were Tmin = 30 °C, Ttop = 80 °C, and εd = 80%, where Tmin denotes the seawater temperature at the dehumidifier inlet and Ttop is the seawater temperature at the inlet of the humidifier. The acceptable accuracy was achieved between the current model and Narayen et al. [30] with a deviation percentage of about 3.87%.

3.1. Recommended Energy Options to Operate the CDI–HDH

The CDI process has a lower energy consumption than HDH, which is a highly energy consuming process because of the higher specific heat capacity of water. Thus, choosing an appropriate environmentally friendly energy source, such as one that does not release CO2 emissions, is crucial. Therefore, two exceptional renewable energy sources for electrical energy and waste heat of renewable energy-based technologies were suggested for the operation of the CDI–HDH hybrid system.
The first one is a photovoltaic thermal (PVT) panel; PVT panels convert solar radiation into electrical and thermal energy. While PV cells convert light energy into electrical energy, the cells get heated; therefore, cooling the cells is important for improving their efficiency and saving them from damage. PVT panels are divided into two main types: PVT liquid type and PVT air collector. Either of these types is useful in the operation of an HDH system because the HDH system may be either a water-heated or air-heated system. Therefore, electrical energy will be used for operating the CDI unit while thermal energy is used to heat air/water in the HDH unit as shown in Figure 14. The second recommended option is wind energy, converted into electrical energy, that would be used for the operation of the CDI unit. Thermal energy can be extracted while cooling the wind turbine generator (cooling is necessary to ensure the longevity of the turbine), and this thermal energy can be used in the HDH unit as shown in Figure 15.

4. Conclusions

This paper theoretically examined the hybridization of CDI and HDH for brackish water desalination using mathematical models of CDI and HDH desalination technologies. The wastewater leaving the CDI unit during the regeneration process still had a significant water content. Instead of discharging this wastewater, it can be further treated to produce distillate by using the waste heat that would instead be dissipated into the environment. Therefore, a CDI–HDH system was created, the wastewater from CDI was treated using HDH, and the effects of different flow rates and salinities for brackish water at the inlet of the CDI unit were analyzed. With an increase in feed water salinity, the specific energy consumption (SEC) of CDI increases, the purity of distillate decreases, and the amount of water produced decreases. This study concluded that using the CDI unit with water containing a higher salt concentration was not a favorable process, while HDH is highly workable for any level of salinity and therefore worked well with CDI wastewater processing.
It was discovered that the amount of water produced from CDI in 11.4 h (for Case 4) was approximately 448 L. Additionally, when the HDH system was operated for the same number of hours, approximately 34 L of water was produced. Therefore, the combined productivity from the CDI–HDH combined system from 11.4 h of operation was higher than that of the CDI unit alone (i.e., approximately 482 L). In addition, the maximum daily total distillation rate was approximately 1079 L/day for Case 5 conditions. The highest recovery rate achieved was 24.90% from the HDH unit at a humidifier inlet water temperature of 80 °C. Additionally, two renewable energy sources were recommended to operate the CDI–HDH system: one using PVT and the other using wind energy. These recommendations were accompanied by a detailed schematic.

Author Contributions

Conceptualization, S.-H.S., Y.A.C.J. and Y.-D.K.; methodology, S.-H.S. and Y.A.C.J.; writing—original draft preparation, S.-H.S., Y.A.C.J., S.M., W.-S.K. and Y.-D.K.; writing—review and editing, S.-H.S., Y.A.C.J. and Y.-D.K.; supervision, Y.-D.K. and W.-S.K.; project adminstartion, Y.-D.K. and W.-S.K.; funding acquisition, Y.-D.K. and W.-S.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Korea Institute of Energy Technology Evaluation and Planning (KETEP) Ministry of Trade, Industry, and Energy (MOTIE) of Republic of Korea, 20194010201740.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

CaCapacitance (F)
CfFeed water concentration in CDI (mol/m3)
cpaSpecific heat capacity of air (kJ/kg °C)
cpvSpecific heat capacity of vapor (kJ/kg °C)
cpwSpecific heat capacity of inlet-concentrated water in HDH (kJ/kg °C)
GORGained output ratio
HaSpecific enthalpy of humid air (kJ/kg)
HwSpecific enthalpy of seawater (kJ/kg)
HpwPure-water-specific enthalpy (kJ/kg)
hfgLatent heat of evaporation (kJ/kg)
ICurrent (A)
m ˙ a Air mass flow rate (kg/s)
m ˙ b Brine mass flow rate (kg/s)
m ˙ w Mass flow rate of concentered water from CDI stack (kg/s)
m ˙ d Distilled water mass flow rate (kg/h)
PatmAtmospheric pressure (kPa)
PsSaturation pressure (kPa)
Q ˙ Heat transfer rate (kW)
SSalinity (g/kg)
STECSpecific thermal energy consumption (kWh/m3)
TTemperature (°C)
Subscripts
1Feed water at inlet of dehumidifier
2Feed water at exit of dehumidifier
3Feed water at humidifier inlet
4Brine at humidifier exit
5Air at dehumidifier outlet/humidifier inlet
6Air at humidifier outlet/dehumidifier inlet
Greek letters
ωHumidity ratio (kgv/kga)
ψRelative humidity (%)
λCharge efficiency
ρDensity of water (kg/m3)

References

  1. World Resources Institute. Available online: https://www.wri.org/ (accessed on 20 April 2021).
  2. World Health Organization (WHO). Available online: http://www.who.int/mediacentre/factsheets/fs391/en/ (accessed on 5 May 2021).
  3. Aamer, A.; Ramoto, A.; Francesca, M.; Efrem, C.; Enrico, D. Membrane technology in renewable-energy-driven desalination. Renew. Sustain. Energy Rev. 2018, 81, 1–21. [Google Scholar]
  4. Leon, A.; Sherman, M.; Randall, S.H.; Victor, V.D. Hybrid desalting systems. Desalination 1989, 76, 189–197. [Google Scholar]
  5. Muhammad, W.S.; Kyaw, T.; Young, D.K.; Kim, C.N. An experimental investigation on MEDAD hybrid desalination cycle. Appl. Energy 2015, 148, 273–281. [Google Scholar]
  6. Lawal, D.U.; Jawad, S.A.; Antar, M.A. Experimental and theoretical study on a heat pump driven open-air humidification dehumidification desalination system. Energy 2020, 207, 118–252. [Google Scholar] [CrossRef]
  7. Emad, A.; Jamel, O.; Abdullah, N.; Jehad, S. Enhancement of brackish water desalination using hybrid membrane distillation and reverse osmosis systems. PLoS ONE 2018, 13, 205012. [Google Scholar]
  8. Jean, P.M.; Stephanie, L.; Corinne, C. Vacuum membrane distillation of seawater reverse osmosis brines. Water Res. 2010, 18, 5260–5273. [Google Scholar]
  9. Lawal, D.U.; Antar, M.A. Investigation of a heat pump-driven humidification-dehumidification desalination system with energy recovery option. J. Therm. Anal. Calorim. 2021, 145, 3177–3194. [Google Scholar] [CrossRef]
  10. Alessandra, C.; Enrico, D. Energetic and exergetic analysis of an integrated membrane desalination. Desalination 1999, 124, 243–249. [Google Scholar]
  11. Farshad, F.; Meisam, K.; Iman, S. Experimental study of a cascade solar still coupled with a humidification-dehumidification system. Energy Convers. Manag. 2016, 115, 80–88. [Google Scholar]
  12. Dahiru, U.L.; Mohamed, A.A.; Atia, E.K. Integration of a MSF Desalination System with a HDH System for Brine Recovery. Sustainability 2021, 13, 3506. [Google Scholar]
  13. Lawal, D.U.; Antar, M.A.; Khalifa, A.; Zubair, S.M.; Sulaiman, F.A. Experimental investigation of heat pump driven humidification dehumidification desalination system for water desalination and space conditioning. Desalination 2020, 475, 114199. [Google Scholar] [CrossRef]
  14. Joel, M.M.; Ramesh, S.; Altaf, H.; Arnold, J.; Samer, A. Field evaluation of membrane distillation followed by humidification/dehumidification crystallizer for inland desalination of saline groundwater. Desalination 2016, 398, 12–21. [Google Scholar]
  15. Sandeep, P.; Farid, M.; Selman, J.R.; Al-hallaj, S. Solar desalination with a humidification-dehumidification technique–A comprehensive technical review. Desalination 2004, 160, 167–186. [Google Scholar]
  16. Lawal, D.U.; Qasem, N.A.A. Humidification-dehumidification desalination systems driven by thermal-based renewable and low-grade energy sources: A critical review. Renew. Sust. Energy Rev. 2020, 125, 109817. [Google Scholar] [CrossRef]
  17. Jande, Y.A.C.; Asif, M.; Shim, S.M.; Kim, W.S. Energy minimization in monoethanolamine-based CO2 capture using capacitive deionization. Int. J. Energy Res. 2014, 38, 1531–1540. [Google Scholar] [CrossRef]
  18. Jande, Y.A.C.; Kim, W.S. Desalination using capacitive deionization at constant current. Desalination 2013, 329, 29–34. [Google Scholar] [CrossRef]
  19. Mostafa, H.S.; Mohamed, A.A.; Syed, M.Z.; Abubaker, M.E. Optimum thermal design of humidification-dehumidification desalination systems. Desalination 2014, 349, 10–21. [Google Scholar]
  20. Karim, M.C.; Narayan, G.P.; Syed, M.Z.; Lienhard, J.H. Use of multiple extractions and injections to thermodynamically balance the humidification-dehumidification desalination system. Int. J. Heat Mass Transf. 2014, 68, 422–434. [Google Scholar]
  21. Mostafa, H.S.; Lienhard, J.H.; Syed, M.Z. Thermophysical properties of seawater: A review of existing correlations and date. Desalin. Water Treat. 2010, 16, 354–380. [Google Scholar]
  22. Hermosillo, J.J.; Bulnes, C.A.A.; Estrada, C.A. Water desalination by air humidification: Mathematical model and experimental study. Sol. Energy 2012, 86, 1070–1076. [Google Scholar] [CrossRef]
  23. Sahali, M.A.; Ettouney, H.M. Humidification dehumidification desalination process: Design and performance evaluation. Chem. Eng. J. 2008, 143, 257–264. [Google Scholar] [CrossRef]
  24. Hamed, M.H.; Kabeel, A.E.; Omara, Z.M.; Sharshir, S.W. Mathematical and experimental investigation of a solar humidification-dehumidification desalination unit. Desalination 2015, 358, 9–17. [Google Scholar] [CrossRef]
  25. Yildirim, C.; Solmus, C. A parametric study on a humidification-dehumidification (HDH) desalination unit powered by solar air and water heaters. Energy Convers. Manag. 2014, 86, 568–575. [Google Scholar] [CrossRef]
  26. Cong, S.; Cheng, J.M.; Cai, J.C.; Sun, R.S.; Dong, J.H.; Guo, F. Thermodynamic analysis and experimental study on humidification-dehumidification desalination system. J. Zhejiang Univ. (Eng. Sci.) 2019, 53, 684–691. [Google Scholar]
  27. Deghani, S.; Date, A.; Akbarzadeh, A. An experimental study of brine recirculation in humidification-dehumidification desalination of seawater. Case Stud. Therm. Eng. 2019, 14, 100463. [Google Scholar] [CrossRef]
  28. Fritzmann, C.; Lowenberg, J.; Wintgens, T.; Melin, T. State-of-the-art of reverse osmosis desalination. Desalination 2007, 216, 1–76. [Google Scholar] [CrossRef]
  29. Anderson, M.A.; Cudero, A.L.; Palma, J. Capacitive deionization as an electrochemical means of saving energy and delivering clean water. Comparison to present desalination practices: Will it compete? Electrochim. Acta 2010, 55, 3845–3856. [Google Scholar] [CrossRef]
  30. Narayan, G.P.; Sharqawy, M.H.; Lienhard, J.H.; Zubair, S.M. Thermodynamic Analysis of humidification dehumidification desalination cycles. Desalin. Water Treat. 2010, 16, 339–353. [Google Scholar] [CrossRef] [Green Version]
  31. Rihua, X.; Shichang, W.; Zhi, W.; Lixin, X.; Pingli, L.; Aimei, Z. Experimental Investigation of a Vertical Tubular Desalination Unit Using Humidification-Dehumidification Process. Chin. J. Chem. Eng. 2005, 13, 324–328. [Google Scholar]
Figure 1. Two modes in the operation of CDI desalination.
Figure 1. Two modes in the operation of CDI desalination.
Energies 14 07641 g001
Figure 2. Working of two CDI stacks. (a) Stack #1 is in adsorption mode and Stack #2 is in regeneration mode. (b) Stack #1 is in regeneration mode and Stack #2 is in adsorption mode.
Figure 2. Working of two CDI stacks. (a) Stack #1 is in adsorption mode and Stack #2 is in regeneration mode. (b) Stack #1 is in regeneration mode and Stack #2 is in adsorption mode.
Energies 14 07641 g002
Figure 4. Schematic illustration of hybrid CDI–HDH system for brackish water desalination. Within CDI unit (A) Stack #1 is in adsorption mode and Stack #2 is in regeneration mode. (B) Stack #1 is in regeneration mode and Stack #2 is in adsorption mode.
Figure 4. Schematic illustration of hybrid CDI–HDH system for brackish water desalination. Within CDI unit (A) Stack #1 is in adsorption mode and Stack #2 is in regeneration mode. (B) Stack #1 is in regeneration mode and Stack #2 is in adsorption mode.
Energies 14 07641 g004
Figure 5. Distilled water flow rate variation with different MRs for all cases of CDI brine.
Figure 5. Distilled water flow rate variation with different MRs for all cases of CDI brine.
Energies 14 07641 g005
Figure 6. HDH brine salinity for different MRs.
Figure 6. HDH brine salinity for different MRs.
Energies 14 07641 g006
Figure 7. Humidity ratio of air across humidifier outlet for different MRs with relatable 90.
Figure 7. Humidity ratio of air across humidifier outlet for different MRs with relatable 90.
Energies 14 07641 g007
Figure 8. Specific thermal energy consumption in HDH at different feed water temperatures at humidifier inlet.
Figure 8. Specific thermal energy consumption in HDH at different feed water temperatures at humidifier inlet.
Energies 14 07641 g008
Figure 9. Distilled water flow rates vs. CDI brine flow rate at dehumidifier inlet for different humidifier inlet water temperatures in HDH with MR = 3 for all five cases of feedwater flow rate.
Figure 9. Distilled water flow rates vs. CDI brine flow rate at dehumidifier inlet for different humidifier inlet water temperatures in HDH with MR = 3 for all five cases of feedwater flow rate.
Energies 14 07641 g009
Figure 10. HDH brine salinity vs. CDI brine flow rate at dehumidifier inlet for different humidifier inlet water temperatures in HDH with MR = 3.
Figure 10. HDH brine salinity vs. CDI brine flow rate at dehumidifier inlet for different humidifier inlet water temperatures in HDH with MR = 3.
Energies 14 07641 g010
Figure 11. Recovery ratio from HDH unit at different humidifier inlet water temperatures.
Figure 11. Recovery ratio from HDH unit at different humidifier inlet water temperatures.
Energies 14 07641 g011
Figure 12. Combined distillate production rate of CDI–HDH system for all five cases.
Figure 12. Combined distillate production rate of CDI–HDH system for all five cases.
Energies 14 07641 g012
Figure 13. Comparison of current HDH model with Narayan et al. [30].
Figure 13. Comparison of current HDH model with Narayan et al. [30].
Energies 14 07641 g013
Figure 14. Schematic of PVT-driven CDI–HDH desalination system.
Figure 14. Schematic of PVT-driven CDI–HDH desalination system.
Energies 14 07641 g014
Figure 15. Schematic of wind energy-driven CDI–HDH desalination system.
Figure 15. Schematic of wind energy-driven CDI–HDH desalination system.
Energies 14 07641 g015
Table 1. Coefficients used in Equation (13).
Table 1. Coefficients used in Equation (13).
a1−2.348 × 104a6−44.17
a23.15 × 105a72.139 × 10−1
a32.803 × 106a8−1.997 × 104
a4−1.446 × 107a92.778 × 104
a57.826 × 103a1097.28
Table 2. Different CDI inlet feed conditions for analysis in this study.
Table 2. Different CDI inlet feed conditions for analysis in this study.
Case No.Feed Salinity (ppm)Flow Rate (L/s)
111,0380.0147
287290.0167
383310.0197
481090.0217
599340.0227
Table 3. CDI output: productivity, purity, cycle time, specific energy consumption, and wastewater salinity for five cases of feed water.
Table 3. CDI output: productivity, purity, cycle time, specific energy consumption, and wastewater salinity for five cases of feed water.
Case No.Amount of Water Produced in One CYCLE (L)Cycle Time (h)Purity of Distilled Water (ppm)Specific Energy Consumption (kWh/m3)Wastewater Salinity (ppm)
1329.412.43350.6522,078
2416.513.82100.5117,456
3436.412.31910.4916,661
4448.411.41810.4716,216
5366.08.92710.5819,867
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Soomro, S.-H.; Jande, Y.A.C.; Memon, S.; Kim, W.-S.; Kim, Y.-D. Integrated Capacitive Deionization and Humidification-Dehumidification System for Brackish Water Desalination. Energies 2021, 14, 7641. https://doi.org/10.3390/en14227641

AMA Style

Soomro S-H, Jande YAC, Memon S, Kim W-S, Kim Y-D. Integrated Capacitive Deionization and Humidification-Dehumidification System for Brackish Water Desalination. Energies. 2021; 14(22):7641. https://doi.org/10.3390/en14227641

Chicago/Turabian Style

Soomro, Sadam-Hussain, Yusufu Abeid Chande Jande, Salman Memon, Woo-Seung Kim, and Young-Deuk Kim. 2021. "Integrated Capacitive Deionization and Humidification-Dehumidification System for Brackish Water Desalination" Energies 14, no. 22: 7641. https://doi.org/10.3390/en14227641

APA Style

Soomro, S. -H., Jande, Y. A. C., Memon, S., Kim, W. -S., & Kim, Y. -D. (2021). Integrated Capacitive Deionization and Humidification-Dehumidification System for Brackish Water Desalination. Energies, 14(22), 7641. https://doi.org/10.3390/en14227641

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop