1. Introduction
Earth’s quantity of freshwater—one of the vital components for life—is shrinking every day, and the situation is further exacerbated by rapid population growth. The prediction in [
1] revealed that by 2040, two-thirds of the world’s population will suffer from a dearth of freshwater. Although the surface of the Earth is 70% water, 97% of that resides in oceans, which have a much higher salt concentration. The salinity of seawater is very high, containing dissolved salts ranging from 10,000 to 35,000 parts per million (ppm). Additionally, the sea contains many impurities like industrial waste materials, domestic waste, mortal remains, sewage waste, etc. Of the remaining 3% of the water on Earth, the majority (77%) is frozen water trapped in glaciers, 1% is in lakes and rivers, and 22% is groundwater. The problem is increasingly serious because the groundwater is also becoming salty due to agricultural chemicals, septic waste, landfill, road salts, underground pipes, hazardous waste, etc., which result in the dissolution of minerals such as anhydrite, carbonates, gypsum, fluoride salts, etc., into groundwater. Therefore, seawater and polluted groundwater are unfit for domestic and industrial use. Water that has a salinity of less than 500 ppm is considered to be freshwater [
2,
3]. To cope with the soaring demand for freshwater, the only choice for producing freshwater is to remove excess salt from seawater and/or brackish water using desalination techniques. Desalination processes such as forward osmosis (FO) and reverse osmosis (RO) require pressure energy to permit the water to flow through the membrane. Multi-stage flash (MSF), multi-effect distillation (MED), solar still (SS), humidification-dehumidification (HDH), and membrane distillation (MD) include phase change and require thermal energy. Capacitive deionization (CDI) and electrodialysis are performed using electrical energy.
In addition to the technologies described above, a hybrid desalination system may be considered. A hybrid desalination system combines two or more technologies. The hybrid system can have more benefits such as higher productivity, energy savings, higher efficiency, and maximizing the overall recovery. Several hybrid desalination systems have been developed during the last few decades and offer promising and improved performance.
Leon et al. [
4] integrated RO with an MSF unit, which provided the benefit of blending the products of these two systems. This results in the operation of RO units with higher total dissolved salts (TDS) and consequently lowers the replacements of membranes and reduces cost by nearly 40%. A hybrid process termed “MEDAD” desalination, which is the combination of MED and adsorption cycle (AD), was proposed by Shahzad et al. [
5]. Their combination allowed MED stages to run at a lower ambient temperature (about 5 °C) compared to the conventional multi-effect distillation (MED) system. The hybrid MEDAD increased productivity from 2.5-fold to 3-fold as compared to MED at the same top brine condition. An HDH desalination system coupled with a heat pump working on a vapor compression cycle was proposed by Lawal et al. [
6]. They conducted an experimental and theoretical study of a system working with an open-water and open-air circulation mode. Their system produced a maximum GOR of 2.72, with a recovery ratio of 2.56%. Meanwhile, the distillate rate from the system was 9.23 kg/h with a unit cost of 15.14 USD/m
3.
Emad et al. [
7] combined the MD and RO units in series for desalting geothermal brackish water. Brine from the MD unit was fed into the RO unit and recycled again to the MD unit. The recycling was found to be highly effective and maximized the freshwater production rate, increased the recovery rate, and reduced the specific energy consumption. The overall recovery rate in the hybrid MD–RO model increased to 40% with an energy cost of 0.9 USD/m
3. The energy cost per cubic meter of water produced was USD 0.9. A VMD (vacuum membrane distillation)–RO hybrid system, where VMD was the complimentary process to the RO unit in order to concentrate the RO brines further, was proposed by Mericq et al. [
8]. Their hybrid system showed a rise in the recovery of the unit. Lawal and Antar [
9] investigated an HDH desalination system coupled with a heat pump. They compared three configurations (A, B, and C) in their system. In A, seawater is heated in a brine heat exchanger (HX) after leaving the dehumidifier; in B, air is heated in an HX after leaving the humidifier; while in C, no HX was employed. Their system produced a recovery of 23.3%, 23.1%, and 15.23% with configurations C, B, and A, respectively.
Alessandra and Enrico [
10] integrated RO with the MD desalination system and performed an energy and exergy analysis of the hybrid system. In their configuration the brine from RO was treated inside the MD unit. The Nano filtration (NF) process was utilized to pretreat the feed prior to using the RO unit. The authors revealed that the proposed system is an alternative to RO and also to thermal desalination techniques. Tabrizi et al. [
11] performed an experimental analysis of a cascade solar still (SS) with HDH desalination for the weather conditions of Zahedan, Iran. The daily production of the SS with and without HDH were obtained for different mass flow rates, and it was concluded that the daily production rate increased from 28% to 141% and the thermal efficiency increased from 9% to 20% in the presence of the HDH system. A hybrid MSF–HDH desalination unit for energy recovery was studied by Lawal et al. [
12]. The MSF–HDH unit increased the overall productivity and performance ratio and reduced brine rejection. Four different configurations of the MSF–HDH unit were proposed and compared. They revealed that the HDH system could use over 66% of an existing MSF brine. Additionally, the MSF–HDH unit had water recovery, productivity, a freshwater cost, and a gained output ratio (GOR) of 44.86%, 30,549 m
3/day, 1.068 USD/m
3, and 8.73, respectively. An HDH system for desalination and space conditioning was investigated by Lawal et al. [
13]. In their system feed water was heated using heat energy from a condenser and at the same time cooling water was cooled further inside the evaporator of the heat pump before it entered the dehumidifier. The air leaving the dehumidifier was traveling to the room for space conditioning. They revealed that the integrated system attained a GOR of 4.07 and the amount of water produced was 287.8 L/day. Additionally, the recovery ratio of the system was 4.86%. The minimum specific energy consumption was 160.16 kWh/m
3.
Another hybrid system, MD–HDH for zero liquid discharge (ZLD) for inland desalination was proposed by Matar et al. [
14]. They found that HDH was effective in the generation of solids from the brine of the MD unit. A 40% recovery rate was produced by the MD producing the freshwater with TDS < 20 mg/L for a flux of 5 L/m
2/h. HDH produced additional freshwater with TDS < 100 mg/L. The energy required for the HDH and MD were 220 kWh/m
3 and 260 kWh/m
3, respectively.
The above literature showed that the integration of two or more desalination technologies had some additional benefits compared to a single desalting unit. Similarly, the hybrid CDI–HDH desalination system was proposed in this system and its explanation is as follows.
Capacitive deionization (CDI) is an advanced method for brackish/groundwater desalination in which water flows between a pair of biased/polarized electrodes. The anions and cations are attracted to the positive and negative electrodes, respectively. In CDI there are two modes of operation: ion adsorption and regeneration. During adsorption, the ions are removed from (treatable) feed water and attached to the electrodes. Regeneration is the reverse of the adsorption process: when the electrodes are saturated, the ions are removed from electrodes by reversing the current or making zero voltage. The water carries away ions during the regeneration mode and rejects it as wastewater, which is higher in salt concentration but still contains water. Treating wastewater is better than discarding it because every drop of water is highly precious. The drawbacks of the CDI process are: it cannot remove bacteria, viruses, or other poisoning materials such as boric acid (dangerous to human health and can cause nausea, vomiting, stomach aches, and diarrhea); and it cannot proceed with high-salinity water. The wastewater that leaves CDI cannot be re-treated using CDI. Proof of this is further explained in detail in
Section 3.
Therefore, wastewater discarded from CDI can be treated in HDH desalination because of its ability to deal with water with a high salt concentration. HDH desalination is an emerging option in the desalination field, particularly for small-scale systems. HDH desalination technology mimics the rain cycle: in a humidifier, either air or water is heated; hot water is sprayed inside the evaporator (humidifier) over packing material; and air flows against the water flow and transports the water vapor at the expense of the heat of the water, leaving behind high-density salts. This hot, humid air is transferred to a dehumidifier, where cold water makes contact with the air and condenses it, thereby producing pure water. HDH desalination technology offers many advantages compared with other methods: it enables a stable and simple control system, does not require strict pretreatment, poses no scaling problem, enables operation at atmospheric pressure, is low maintenance, and has no sensitivity to water with a high salt concentration [
15]. One of the major benefits of the HDH system is that it can be operated using any low-grade waste heat [
16].
In this study, brackish water was treated inside the CDI unit, and wastewater leaving the CDI unit was further treated in the HDH desalination unit in order to recover more distillate water. Therefore, a theoretical study was carried out using the mathematical model of CDI and HDH desalination systems.
3. Results and Discussion
Five different cases of CDI inlet feed flow rates and salinities were considered for analysis, as shown in
Table 2. The salinities of feedwater at the inlet were selected considering the fact that brackish water salinity ranges from 1500 to 15,000 ppm [
28]. For each case of the CDI unit, the productivity, cycle time, purity of distilled water, and energy consumption were determined, as shown in
Table 3.
The results in
Table 3 illustrate the reason that CDI cannot work with higher feed concentrations: an increase in the feedwater salinity increases the specific energy consumption (SEC), reduces the distillate water purity, and reduces the production of distillate. In Case 1, when the highest feed salinity is considered, i.e., 11,038 ppm, the energy consumption is also highest at 0.65 kWh/m
3 and the purity of the distilled water is also reduced; in other words, the salinity of the distillate water is increased. Additionally, the amount of water produced is lower, at 329.4 L per cycle.
As the salinity decreased in Cases 2, 3, and 4, it can be seen that the SEC also decreased to 0.51, 0.49, and 0.47 kWh/m3, respectively; the purity of the distilled water increased to 210, 191, and 181 ppm, respectively; and the amount of water produced increased to 416.5, 436.4 and 448.4 L per cycle, respectively. For Case 5, when the salinity was again increased, the results showed that the SEC increased to 0.58 kWh/m3, the purity decreased to 271 ppm, and the amount of water produced was 366 L. It can also be seen that an increase in the feedwater salinity increases the salinity of the wastewater and distillate; therefore, CDI operation at higher salinities is not favorable because it will not produce distillate within a potable range.
The wastewater from the CDI unit had a higher salinity that was beyond the operating limit of CDI [
29] and therefore this wastewater was treated inside the HDH desalination unit. The wastewater leaving the CDI unit during the regeneration process is fed into the HDH unit at a dehumidifier inlet at room temperature at 25 °C. Since the mass flow rate of wastewater cannot be changed in the HDH, the only parameters that can be altered inside the HDH unit are mass ratio (MR), which is the ratio of water mass flow rate to the air mass flow rate defined by Equation (22), and the humidifier inlet water temperature
T3, which is the wastewater temperature at the humidifier inlet. To evaluate the system performance of the HDH unit, the mass ratios (MRs) from one to six were considered. This range was considered in order to find out the optimal MR, keeping in mind that the MR should be more than or equal to one for balanced conditions [
30]. The air flow rate in the MR was changing but the feed water flow rate was kept constant. The humidifier inlet water temperature
T3 was selected to be 50–80 °C because this operating range is preferred, provided that a heat source is available and materials are durable [
31].
The effect of the MR on HDH performance was investigated. The MR was set from one to six, and the distillate production rate from the HDH unit vs. the MR is shown in
Figure 5. The results showed that the distillate production rate for all cases of wastewater increased with an increase in the MR up to three, and the distillate production rate decreased after that with a further increase in the MR. This is because for an MR of three, the contact time between the air and water increases, and the air carries away more moisture from the humidifier, but the larger the MR, the shorter the residence time, and the air is discharged from the humidifier without getting enough moisture. The productivity was the lowest at an MR of six in all cases.
Figure 6 shows that at MR = 3, the salinity of the HDH brine was higher at higher flow rates (Case 1) because higher evaporation occurred at this MR, leading to more concentrated brine exiting the humidifier, while at a higher MR less evaporation occurred, which results in brine exiting with a lower salt concentration.
Figure 7 shows the variation in the moisture content (humidity ratio of the air) with an increase in the MR for all five cases. The results indicated that the humidity ratio of the air across the humidifier outlet was highest in Case 5 with an MR of three and lowest in Case 1 with an MR of six.
The effect of the humidifier inlet water temperature on the specific thermal energy consumption rate (STEC) is depicted in
Figure 8. It can be seen that at higher values of
T3 energy consumption was lower while at lower values of
T3 the STEC was very high.
The effect of the humidifier inlet water temperature
T3 on the distillate production rate is shown in
Figure 9. It can be seen that the highest distillate production rate (3.83 kg/h) was recorded at the higher humidifier inlet water temperature and higher CDI brine flow rate at the dehumidifier, i.e., 80 °C and 0.0227 kg/s, respectively. This is because at a higher humidifier inlet water temperature, the evaporation rate is also higher. At a higher feedwater flow rate (0.0227 kg/s), the distillate production rate also increases because the surface temperature of the dehumidifier is reduced and causes more condensation, which in turn collects more distillate at the dehumidifier bottom.
Figure 10 shows the effect of humidifier inlet water temperature on outlet brine salinity from HDH. It was observed that at higher humidifier inlet water temperatures the brine salinities were also higher. This is because at a higher humidifier inlet water temperature, evaporation is higher, and this leads to more concentrated brine exiting the humidifier. At 80 °C, the salinity of the HDH brine was higher, with a concentration of about 30,000 ppm.
Figure 11 shows the effect of the humidifier inlet water temperature on the recovery ratio (RR) from HDH. It was observed that at higher humidifier inlet water temperatures the
RR was higher. This is because at higher humidifier inlet water temperatures, the distillate production rate was also higher. The
RR was 3.92%, 7.54%, 13.71%, and 24.90% at 50 °C, 60 °C, 70 °C, and 80 °C, respectively, for a wastewater salinity of 22,078 ppm.
The combined distillate production rate of the CDI–HDH system per day for all cases is shown in
Figure 12. The highest production rate was approximately 1079 L/day for Case 5 (
= 0.0227 kg/s, feed salinity 19,867 ppm), and the lowest rate was approximately 697 L/day for Case 1 (
= 0.0147 kg/s, feed salinity 22,078 ppm). The results shown in
Figure 11 were obtained based on the following HDH conditions: MR = 3.0; component effectiveness = 80%; humidifier inlet water temperature = 80 °C.
Figure 13 demonstrates the results of the present HDH model and that of Narayen et al. [
30]. The variation of the GOR (defined by Equation (24)) versus the MR for the humidifier effectiveness (
εh) of the different systems was determined. The MR is the ratio of the seawater mass flow rate to the air mass flow rate. The operating conditions were
Tmin = 30 °C,
Ttop = 80 °C, and
εd = 80%, where
Tmin denotes the seawater temperature at the dehumidifier inlet and
Ttop is the seawater temperature at the inlet of the humidifier. The acceptable accuracy was achieved between the current model and Narayen et al. [
30] with a deviation percentage of about 3.87%.
3.1. Recommended Energy Options to Operate the CDI–HDH
The CDI process has a lower energy consumption than HDH, which is a highly energy consuming process because of the higher specific heat capacity of water. Thus, choosing an appropriate environmentally friendly energy source, such as one that does not release CO2 emissions, is crucial. Therefore, two exceptional renewable energy sources for electrical energy and waste heat of renewable energy-based technologies were suggested for the operation of the CDI–HDH hybrid system.
The first one is a photovoltaic thermal (PVT) panel; PVT panels convert solar radiation into electrical and thermal energy. While PV cells convert light energy into electrical energy, the cells get heated; therefore, cooling the cells is important for improving their efficiency and saving them from damage. PVT panels are divided into two main types: PVT liquid type and PVT air collector. Either of these types is useful in the operation of an HDH system because the HDH system may be either a water-heated or air-heated system. Therefore, electrical energy will be used for operating the CDI unit while thermal energy is used to heat air/water in the HDH unit as shown in
Figure 14. The second recommended option is wind energy, converted into electrical energy, that would be used for the operation of the CDI unit. Thermal energy can be extracted while cooling the wind turbine generator (cooling is necessary to ensure the longevity of the turbine), and this thermal energy can be used in the HDH unit as shown in
Figure 15.
4. Conclusions
This paper theoretically examined the hybridization of CDI and HDH for brackish water desalination using mathematical models of CDI and HDH desalination technologies. The wastewater leaving the CDI unit during the regeneration process still had a significant water content. Instead of discharging this wastewater, it can be further treated to produce distillate by using the waste heat that would instead be dissipated into the environment. Therefore, a CDI–HDH system was created, the wastewater from CDI was treated using HDH, and the effects of different flow rates and salinities for brackish water at the inlet of the CDI unit were analyzed. With an increase in feed water salinity, the specific energy consumption (SEC) of CDI increases, the purity of distillate decreases, and the amount of water produced decreases. This study concluded that using the CDI unit with water containing a higher salt concentration was not a favorable process, while HDH is highly workable for any level of salinity and therefore worked well with CDI wastewater processing.
It was discovered that the amount of water produced from CDI in 11.4 h (for Case 4) was approximately 448 L. Additionally, when the HDH system was operated for the same number of hours, approximately 34 L of water was produced. Therefore, the combined productivity from the CDI–HDH combined system from 11.4 h of operation was higher than that of the CDI unit alone (i.e., approximately 482 L). In addition, the maximum daily total distillation rate was approximately 1079 L/day for Case 5 conditions. The highest recovery rate achieved was 24.90% from the HDH unit at a humidifier inlet water temperature of 80 °C. Additionally, two renewable energy sources were recommended to operate the CDI–HDH system: one using PVT and the other using wind energy. These recommendations were accompanied by a detailed schematic.