1. Introduction
Spray drying is a process in which a concentrated liquid feed is atomized in the presence of a drying medium (usually hot air) to obtain a solid powder. It originates from the dairy industry [
1]; nonetheless, today, process industries ranging from food, pharmaceutical, chemical, ceramics, and cosmetics benefit from this process [
2]. In conventional spray dryers, the contact between the droplets and air is done in either a co-current or counter-current manner. In a co-current configuration, both droplets and hot air enter the drying chamber from the same side. This configuration frequently is applied to dry heat-sensitive materials such as food products, since the product temperature does not exceed 100 °C [
3]. In contrast, in the counter-current configuration, droplets are sprayed from the opposite side to the airflow. The relatively high slip velocities of particles result in high heat and mass transfer, and therefore, these dryers are considered to have higher throughput and thermal efficiencies than co-current spray dryers [
4,
5]. This configuration is primarily suitable for thermally stable materials such as detergents [
5,
6].
Conventional co-current spray dryers account for 27–55% of the total energy demands in the dairy industry [
7]. To avoid product degradation, the temperature inside the dryer is kept relatively low, which implies small drying rates [
3]. To sufficiently dry the feed, particles have long residence times, leading to large equipment size and high capital costs [
8,
9]. Furthermore, the terminal velocities of the particles result in small gas–solid slip velocities, restricting the heat and mass transfer.
In order to develop an alternative commercially viable and process-intensified spray-drying technology, high drying rates in a small volume must be achieved, while the residence time of droplets/particles must be reduced to maintain product quality [
8]. This can be done by operating the dryer as a multizone vortex chamber unit, which is the topic of this research.
In a Vortex Chamber (VC), the rotational motion of the gas is achieved by the tangential injection of gas through multiple inlet slots located in the periphery of the chamber [
10,
11]. Droplets/particles can be fed and removed via one of the end walls in the chamber, while the gas, after particle separation, leaves the chamber through a centrally positioned gas outlet chimney. An example configuration of a VC is presented in
Figure 1. The centrifugal forces in the VC can be much higher than the gravitational forces, resulting in high gas–solid slip velocities and the formation of a dense particle bed. These intensify the heat, mass, and momentum transfer [
11,
12,
13].
The process intensification in a gas–solid VC has been experimentally and/or numerically demonstrated for many applications such as biomass gasification [
14], biomass fast pyrolysis [
15], fluid catalytic cracking [
16], and drying [
17,
18,
19]. The drying of polymer materials (polystyrene emulsion, sulfadiazine) for the removal of superficial moisture was experimentally demonstrated by Kochetov et al. [
19,
20]. Their study summarized optimal ratios for vortex chamber design. Lazar and Farkas [
21] reviewed fluidized bed drying of food materials using a centrifugal field wherein the potential advantages and challenges were discussed. Eliaers and De Wilde [
13] compared a conventional fluidized bed and a Rotating Fluidized Bed (RFB) for the drying of woody biomass particles. The authors showed the formation of a uniform and dense particle bed using high-G acceleration that gave substantial benefit, especially in the first drying stage. More recently, Eliaers et al. [
22] studied the application of particle coating; their results suggested that VC allows for short contact time between particles and gas and promotes a small particle residence time in the reactor. Both are beneficial for process intensification.
The evolution of a VC is a Radial Multizone Dryer (RMD) [
23,
24,
25,
26]. In this configuration, hot air enters axially into the central zone while the vortex is created via relatively cold airflow entering the RMD via the tangential channels; see
Figure 2. The process intensification is an outcome of both multizone drying operation with high and low temperature air feeding zones and high-G acceleration. Consequently, the drying occurs in two steps: (i) the majority of drying takes place in the central hot zone where very small droplets/particles are exposed for few milliseconds to temperatures of 350–400 °C coming from counter-flowing hot air and (ii) at the peripheries of the RMD, where the particles are exposed to strong centrifugal forces coming from the rotating air at a temperature of 80–120 °C. By rapid evacuation of dried particles to a colder rotating environment, product degradation due to high gas temperatures is avoided. This way, two drying zones are established: a fast drying zone in the radial center and a final slow drying zone in the periphery of the chamber. The former leads to enhanced drying rates, and the latter intensifies air–droplet contact and air–solid separation.
In order to prevent particle overheating (during the 1st drying step in RMD) and to minimize product losses via the gas outlet, the separation of the dried particles from the central hot zone to the cold peripheral zone of VC is of prime importance. The centrifugal forces in the reactor are a function of chamber dimensions, air inlet slot size, operating conditions, and particle properties [
11]. Trujillo and De Wilde [
27] experimentally demonstrated that particle losses via the central gas outlet could be significantly reduced by locating the solids outlet to an optimum position for a given particle type and size. Furthermore, with an increase of the injection velocity via the tangential inlets, higher centrifugal forces were observed in the chamber, improving particle retention. Weber et al. [
28] conducted experiments on a binary mixture of granular materials and showed the effects of separation and segregation due to their different sizes and density. The authors concluded that for a fixed gas flow rate, different particle types (size and density) experience different centrifugal forces on them. Once the centrifugal forces are less than the inward drag forces, the particles will leave the VC. De Wilde et al. [
29] further showed the potential of high-G gas–solid contact, gas–solid separation, and particle segregation in a rotating fluidized bed. There, the particle losses via the gas outlet were reduced by increasing the gas flow rate. The large particles formed a dense uniform bed near the wall, whereas a less dense bed was seen for small particles. Thus, the high-G acceleration in the chamber could be varied by either increasing the gas flow rate or by adjusting the number or width of injection slots. Based on the above studies, an optimum design configuration of VC for a particular application, such as spray drying, requires a parametric investigation of the factors mentioned above [
11,
28].
Experiments involving multiphase flows and high-temperature gradients are very challenging and time-consuming. Furthermore, often, the process conditions and measurement techniques are limited by the design of the experimental setup, as well as by the complexity and non-linearity of the process [
30]. In recent years, Computational Fluid Dynamics (CFD) has proven to be an extremely useful tool in designing new dryers and optimizing existing processes for the food industry [
31,
32,
33]. Hence, in this study, we employ a CFD approach as well.
Huang et al. [
34,
35] performed a comprehensive study of gas flow patterns, evaporation zones, and droplet impact positions at different operating conditions and different co-current spray dryer geometries. A steady-state axisymmetric model with the k-epsilon approach for the gas phase turbulence was employed. For the droplet phase, the authors used properties of water with varying solid content, while the droplet size range of approximately 10–120 µm was prescribed. For model validation, the authors used the geometry and boundary conditions from previous works [
36,
37]. The results showed that droplets have different trajectories and drying histories owing to the differences in the airflow dynamics and temperature patterns. Anandharamakrishnan et al. [
38] performed three-dimensional, steady-state simulations to compare the drying trajectories in a short form and tall form spray dryer. The feed properties were assumed to be of maltodextrin solution (42.5 wt %), assuming only surface moisture evaporation. The gas phase turbulence was resolved using the k-epsilon model. The model predictions corresponded well with the experimental measurements taken by Kievet [
36]. The authors found short-form dryers to be more suitable for heat-sensitive materials due to the shorter particle residence times. The advantages of using superheated steam as a drying medium were demonstrated by Frydman et al. [
39]. A 2D steady-state approach was employed while the turbulence was accounted for by the k-epsilon model. Different droplet sizes (12–83 µm) were injected using a constant velocity at the nozzle orifice and assuming a flow with water properties. The model predictions matched well with the measured temperature data in the dryer. The model was extended further by Ducept et al. [
33] to predict the Residence Time Distribution (RTD) of dry particles by including 10 wt % of dry matter (KCl solution) in the liquid droplet; however, the drying kinetics were not included. In this way, once all the water was evaporated, solid particles could leave the dryer after a certain residence time. The authors validated this approach by comparing the experimental and numerical RTD with reasonable accuracy. The authors demonstrated the feasibility of using superheated steam with the advantages of higher drying rates.
Recently, Ali et al. [
6] studied a counter-current spray-drying tower with an inlet swirl for detergent production. Comparing the model predictions with the experimental measurements at the exhaust location revealed underprediction of the heat transfer rate resulting in higher exhaust temperature and particle moisture content by the CFD model. The authors owed the discrepancies to the differences in the initial droplet size distribution and the underprediction of the particle residence times.
In the above-presented studies, an Euler–Lagrangian multiphase model was employed with two-way coupling between the gas and droplet phase via the particle-source-in-cell method of Crowe [
40].
In the VC-related CFD research, Broqueville and De Wilde [
41] investigated the gas–solid heat transfer in a VC with an RFB and compared it to conventional fluidized beds using a 2D model. The presence of a uniform and dense bed as observed experimentally was confirmed via the CFD simulations. Furthermore, the results prove the heat and mass transfer intensification in a VC. Trujillo and De Wilde [
16] applied 2D CFD simulations with reactions to demonstrate the use of RFB for the catalytic cracking of gas oil. Only qualitative validation was performed based on experimental observations. The authors reported significant process intensification (compared to conventional risers) despite utilizing a non-optimized VC. A detailed study on the operating conditions and different designs was carried out by Dutta et al. [
42] to study the hydrodynamics behavior of different Geldart group particles. Similar to previous authors, no direct validation was performed; nevertheless, the model showed similar trends to experimental observations of De Wilde and Broqueville [
10]. The authors displayed the advantages of CFD in evaluating different operating conditions and design scenarios of VC configuration. Niyogi et al. [
43] performed 3D simulations of a vortex unit operating with a particle size of 0.5–2 mm. The authors examined the influence of gas flow rate, particle diameter, and solids density on the hydrodynamics behavior, optimizing the configuration and conditions for a given application.
In the VC studies mentioned above, the authors used the Eulerian–Eulerian multiphase model combined with the kinetic theory of granular flow (KTGF) for the solid phase equations. The gas phase turbulence was accounted for by using a k-epsilon-type approach with standard wall functions. The wall boundary conditions for the gas phase were prescribed as no-slip, whereas partial slip or free slip conditions were used for the solid phase. Recently, an Euler–Lagrangian-based Computational Particle Fluid Dynamic (CPFD) model was studied by Dutta et al. [
44]. From the study, the authors found a strong effect of particle size, number of gas inlet slots, and their width on the gas-particle hydrodynamics in the VC. The predicted results showed similar trends with the reported experimental data.
In the present paper, the application of spray drying in a VC technology is numerically studied. The hypothesis, that high drying rates while maintaining small particle residence times can be achieved using high air inlet temperature and high-G acceleration in a multizone VC geometry, is tested by assessing the separation efficiency of the product. The results of temperature and moisture fields, high-G acceleration, and droplet drying histories are presented.
3. Results
In order to assess the performance of the model, first, a validation study is performed. The numerical results are compared with the temperature profiles of experiments conducted without and with droplet spray, see
Figure 4 (left) and
Figure 4 (right), respectively. The thermocouples V12 and V13 are located in the central core region of VC, and they measure the temperature at each VC wheel in the axial direction.
The results show that the numerical temperature profile for only-gas flow corresponds well with the experimental measurements. The average error is equal to 1% for V12 and 4% for the V13 probe. The slight overprediction in temperature is attributed to the assumption of adiabatic walls, whereas some heat losses are expected during the experiment.
The experimental data with water spray show a strong asymmetry between results from probes V12 and V13. This trend is not well pronounced in the numerical data; however, the overall error is in the range of 4% and 8% for probes V12 and V13, respectively. It should be noted here that drying experiments with the utilization of spray are typically burdened with higher measurement error compared to gas-flow-only experiments. This is due to the possible wetting of the thermocouples and non-uniformity in the spray pattern.
In conclusion, the predicted numerical results correspond sufficiently well with temperature measurements. A detailed discussion regarding the validation results is given in our former paper [
23].
3.1. Effect of Solids Outlet
The influence of the location of solids outlet on the performance of RMD is investigated for three cases “A–C”. In case “A”, the solids outlet is located close to the gas outlet, whereas in cases “B–C”, it is moved radially outwards, at the front and back wall, respectively; see
Figure 5. Detailed boundary conditions are presented in
Table 1.
The predicted temperature and moisture fraction profiles of air are presented in
Figure 5 and
Figure 6. The temperature of the gas decreases along the chamber length due to the heat exchange between hot air coming from the inlet and counter-flowing evaporating spray. In general, the temperature profile for all three cases is similar. The same is true for the moisture profile. The maximum evaporation occurs in the hot zone, resulting in the most pronounced temperature drop. The temperature and moisture fraction values are fairly uniform in the radial peripheries of the VC, implying that almost no evaporation takes place in this zone. This behavior suggests that droplets upon reaching the VC are already dried.
All droplets are injected with a constant velocity. However, due to different diameters and mass, they exert different momentum on the counter-flowing hot gas. Thus, as a result, the penetration depth and stagnation point of the droplets in the hot zone vary significantly. Heavy droplets penetrate further into the hot cylinder compared to small droplets, whereas the small and light droplets are quickly deflected and move toward the radial peripheries of the VC. This way, RMD offers a unique feature wherein heavy droplets (least dry) meet the gas at the high temperature (approximately 350 °C) and fine droplets are exposed to the relatively low gas temperature (approximately 215 °C).
Although the general profiles of the investigated cases are similar, a detailed view on the temperature and air humidity profiles, see
Figure 7 and
Figure 8, respectively, reveals differences in the drying behavior of the droplets.
From
Figure 7, it is possible to note an asymmetric behavior of the spray, i.e., the penetration depth, and thus also the temperature and moisture profiles are different at the presented cross-sections. For case “A”, the droplets cannot penetrate further into the hot zone; thus, the temperature and moisture fraction profiles are relatively uniform with minor heat and mass exchange (seen clearly in
Figure 7c,d). The temperature and moisture fraction profiles for cases “B” and “C” show a temperature drop from 350 °C to approximately 120–130 °C and maximum moisture fraction values of about 0.095 kg/kg.
The plots also show a uniform distribution of temperature and humidity in the central region. This is due to the hollow cone spray pattern that creates a low-pressure region, forcing hot air to pass through. The hot air, due to the momentum transfer between air and droplet/particles, is forced radially toward the walls. Therefore, high temperatures are seen at and next to the walls with a gradual radial temperature drop as a result of heat transfer from the droplets. A maximum temperature drop and consequently the highest moisture fraction values are observed for the case “C”. This implies that the droplet penetration is maximum in case “C”. The lowest temperature drop and thus lowest air moisture fraction values are seen for case “A”.
Figure 8 presents the radial gas temperature and moisture fractions profiles at the axial location z/Z = 0.55. Comparing the cases, the plot in
Figure 8 depicts similar trends as shown earlier with hot air penetrating through the central low-pressure region of a hollow cone, therefore resulting in higher temperatures in the centerline of the chamber with a sharp decrease in temperatures in the outward radial direction, owing to the intense heat and mass transfer around the spray region. The peaks at r/R
0.3 and r/R
0.7 are mainly due to momentum exerted by the spray on the hot air, forcing hot air to go around the hollow cone spray. The temperature of the air in the VC and near the walls is mainly uniform, revealing that no evaporation takes place in the VC region. The expansion of the hot zone for the case “B” (near the walls) arises due to the bending movement of the hot air toward the solids outlet located on the front end wall. Such high temperatures close to the product outlet can lead to product burning and should be avoided. The moisture fraction plots in
Figure 8 show opposite behavior to the temperature fields with hot dry air passing through the centerline of the VC and a sharp increase in moisture fraction observed radially outward around the spray nozzle. This is mainly due to the evaporation of smaller/fine droplets that results in high heat and mass exchange, showing peaks of moisture fraction and low gas temperature. Finally, it can be seen that the peaks of water mass fraction in case “C” show the highest values. This depicts efficient evaporation in the central fast drying zone.
Comparing the separation efficiency for cases “A–C”, see
Figure 9, it can be seen that the highest weight percentage of the product recovered at solids outlet is for the case “C”. This is 42 wt %. Around 40 wt % is evacuated via gas outlet, and the remaining mass is lost via the boundary walls; see previous sections for details. For case “A”, the majority of the product is leaving via the gas outlet, which is highly undesirable. This is mainly a consequence of a low-pressure region created by the gas and solids outlet being next to each other. This also compromises the separation of bigger and smaller particles from each other. We observe similar behavior for case “B” when the solids outlet is located at the front wall. The reason for that is partly due to the fact that the gas flows via the VC air inlets are not optimized and drive the particles toward the front wall. Here, also, about 17 wt % of the particles impinge the cylinder walls. Since these are still wet particles, they are removed from the domain.
Based on the above-presented analysis, case “C” offers the most desired behavior, and hence, it is used for further investigations.
3.2. Effect of Relative Hot/Cold Air Ratio
An analysis of separation efficiency, see the previous section, revealed that approximately 40 wt % of the product is lost via the gas outlet. Previously, it has been studied experimentally that the particle losses, via the central exhaust chimney, can be significantly reduced provided that the centrifugal forces in the VC are higher than the gas–solid radial drag forces [
29,
45]. Here, the average relative centrifugal force
is used to quantify the magnitude of the rotational motion of gas. It is expressed as a multiple of the gravitational force and is helpful in comparing different conditions [
42]. The centrifugal acceleration is calculated from:
where
is the tangential velocity (m/s) in the chamber,
r is the radius of the chamber, and
g is the acceleration due to gravity. From Equation (1), it is evident that the G–acceleration in VC is a function of the gas tangential velocity, which is dependent on either the gas volumetric flow rate or the number of gas inlet slots and/or slot width. Thus, to change the G-acceleration for a fixed design, the gas flow rates via the VC tangential inlets need to be adjusted. This is studied in terms of relative hot/cold airflow ratio of 1.25, 1.0, and 0.75; case “C”, “D”, and “E”, respectively (see
Table 1).
Figure 10 presents the G-acceleration as a function of the radial distance. The corresponding average centrifugal force for cases “C”, “D”, and “E” is 81, 133, and 240 g, respectively. The centrifugal force is highest for the case “E” due to major airflow via the tangential inlets of the VC, resulting in high tangential velocities. This leads to a significant volume fraction of particles being radially pushed outwards to the periphery of the VC, causing high momentum transfer between the gas phase and particles, as presented in
Figure 11, depicting the iso-surfaces of volume fraction at a value of 5 × 10
−4. Here, the particles are instantly separated from the central axial hot airflow and entrained into the VC to form a rotating particle bed. In case “E”, the peripheries of the VC are almost completely occupied with the particles, while in case “C” and “D”, the G-acceleration is not sufficient to separate the particles efficiently. Therefore, the particles tend to move axially toward either of the end walls—front or back. Consequently, in case “C” and “D”, particles rotate adjacent to the back wall. In case “E”, it can be seen that a relatively large amount of particles are separated and rotate in the center of the chamber. This is because the tangential velocities are maximal in the central two wheels.
The findings of the above-presented discussion have confirmation in the separation efficiency where case “E” outperforms the other two cases with a total separation efficiency of 60 wt %; see
Figure 12. From the
Figure 12, also a correlation between the average relative centrifugal forces in the VC and product obtained at the solids outlet is evident. A similar trend was also observed by other authors [
44]. The reason, as explained in the preceding discussion, owes to the centrifugal forces being greater than the drag forces acting inwards and forcing the particles to leave axially via the gas outlet.
3.3. Effect of Droplet Size Distribution
Three simulation cases, with SMD kept constant at 52 µm, are presented here. Case “E” is the one discussed in the previous section with a droplet size distribution between 30 and 85 µm, case “F” has a droplet size distribution between 20 and 95 µm, and case “G” has a droplet size distribution between 45 and 70 µm.
Figure 13 shows the weight percentage of the product recovered at the outlet. As the droplet size range is narrowed down to 45–70 µm (case “G”), the separation efficiency increases to about 85 wt %. In contrast, the separation efficiency considerably drops down to approximately 26 wt % when a wider droplet size range is specified; see case “F”. Such behavior has an origin in the size of the biggest and smallest droplets and the paths they follow. The big droplets can travel deep toward the hot air inlet, whereas the small ones are instantaneously deflected back to the gas outlet. Thus, a narrow size distribution of the droplets is beneficial for good product separation.
This has further confirmation in Particle Size Distribution (PSD); see
Figure 14a, as discussed for the case “F”. Here, more than 90% of the mass is carried out by product particles smaller than 32 µm (corresponding to initial “wet” particle size of 47 µm). Only about 10 wt % of the particles come from big droplets. In contrast, at the solids outlet (
Figure 14b), approximately 85 wt % of the product particles are equal to or bigger than 32 µm.
Figure 15a,b show the predicted RTD as a function of mass flow at the gas outlet and solids outlet, respectively. The mean residence time of the particles at the gas outlet is equal to 0.04 s, and at the solids outlet, it is equal to 0.67 s. Small droplets with small initial masses quickly dry and shrink in size. They have short relaxation times (low Stokes number < 0.1), causing the particles to act as tracers in the central axial flow and leave via the gas outlet. Furthermore, due to the relatively smaller centrifugal forces acting on these fine particles, they are not separated, resulting in particle losses via the gas outlet and correspondingly short residence times.
The longer residence times of the big particles owe to their large inertia so they can penetrate deeper into the counter flowing hot air. After losing sufficient momentum, the particles, due to centrifugal forces, are separated radially outward to the periphery of the VC, where as a result of tangential momentum exchange, they start rotating and finally leave the reactor via the solids outlet; see also
Figure 16. This analysis shows a key feature of spray drying in an RMD, i.e., the separation of bigger and smaller particles and hence, different drying histories for different droplet sizes.
4. Conclusions
Three-dimensional multiphase CFD simulations of counter-current spray drying process in a novel lab-scale RMD have been carried out. For modeling, a two-way coupled heat, mass, and momentum exchange between the discrete and gas phase (Euler–Lagrangian approach) were used. The detailed information on temperature and moisture profile, G-acceleration, droplet/particle trajectory, drying history, particle residence time, and separation efficiency were obtained.
The results showed that it is possible to establish two separate and distinct temperature zones within RMD: (i) a very hot, quick drying central zone in its center and (ii) a cold rotating zone, i.e., the final drying zone in the periphery of VC. The parametric study revealed a strong influence of solids outlet position, G-acceleration, and initial droplet size distribution on the separation efficiency of the product. The location of the solids outlet at the periphery of VC on the back wall gave the most promising results in terms of heat and mass transfer characteristics and separation efficiency, whereas its placement next to the gas outlet resulted in asymmetric spray behavior with minimal evaporation in the hot zone and compromised separation efficiency. Similarly, a direct correlation was noted between separation efficiency and G-acceleration. A relative hot/cold airflow ratio of 0.75 corresponding to average G-acceleration in the VC of about 250 g was found to be optimal. The separation of the product at the solids outlet was enhanced from 42 wt % to 60 wt %. In contrast, at higher relative hot/cold airflow ratios and consequently smaller G-acceleration, considerable particle losses occur via the gas outlet. This is due to smaller centrifugal forces in the VC. Finally, the influence of droplet size distribution was investigated. When a wide droplet size distribution (20–95 µm) is applied, a significant decrease in separation efficiency is observed (26 wt %). Bigger particles (>75 µm) impinge the hot air inlet, whereas the smallest particles instantly leave the reactor via the gas outlet. By narrowing the droplet size distribution (45–70 µm), the total separation efficiency was increased to 85 wt %; thus, depicting the strong correlation between the particle size and separation efficiency. Furthermore, results also revealed that the in situ separation of bigger and smaller particles leads to distinct drying histories. The majority of the bigger particles (>32 µm) leave via the solids outlet and have a mean residence time of 0.67 s, whereas particles leaving via the gas outlet are mostly smaller particles (<32 µm) having a short residence time of 0.04 s. The results of this study confirm the hypothesis that by combining high air inlet temperatures and efficient particle separation using high-G acceleration, an intensified spray-drying process with high drying rates and small particle residence times can be achieved in an RMD.