Energy Performance of Verandas in the Building Retrofit Process

by
Rossano Albatici
1,*,
Francesco Passerini
1 and
Jens Pfafferott
2
1
Department of Civil Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123 Trento, Italy
2
Department of Mechanical and Process Engineering and Institute of Energy System Technology, Offenburg University of Applied Sciences, Badstraße 24, 77652 Offenburg, Germany
*
Author to whom correspondence should be addressed.
Energies 2016, 9(5), 365; https://doi.org/10.3390/en9050365
Submission received: 30 January 2016 / Revised: 13 April 2016 / Accepted: 29 April 2016 / Published: 13 May 2016
(This article belongs to the Special Issue Energy Efficient Building Design 2016)

Abstract

:
Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.

1. Introduction

Research on passive solar systems is not a new issue. Great efforts were made towards more energy efficient buildings in the seventies following the 1973 oil crisis, and several books on the proper design of passive devices were published. Just consider, for example, the work of Mazria defined by Loss as “the first handbook completely dedicated to the design of passive buildings which systematically deals with the problems of their design and construction” [1]. Alternatively, the more recent one from Steven Winter Associates [2] presents operating principles of sunspaces, rules of thumb for dimensioning, different solutions for design and control strategies and constructive details. These publications were mainly qualitative, giving design patterns in the form of empirical rules useful for designers to develop proper passive strategies. Later on, the need for quantitative analysis of the real performance of passive solar design principles arose [3]. Since then, also due to the increasing capacity of computational tools and to the higher precision of dynamic simulation models, several studies have been made on passive systems, and they are still ongoing.
Among the different passive systems, designers have often preferred sunspaces because they act not only as heat storage systems, but also because they define a space with high quality of living, often required by clients as winter gardens. In this field, one of the early works was from Wall [4], which investigates in depth several aspects linked to glazed spaces: examples from past architecture, proposals of simplified design tools, and evaluation and comparison of different design possibilities. Moreover, monitoring and analysis of a great variety of real cases in Sweden are presented, performing both stationary and dynamic calculations in order to investigate the influence of design on inner climate (comfort analysis) and energy requirements. Mihalakakou and Ferrante [5] performed a sensitivity analysis in order to investigate the impact of different parameters on the energy potential of sunspaces. Afterwards they focused on the simulation and monitoring of real cases [6]. Several studies have been made comparing monitoring of sunspaces in experimental setups and simulation results, in order to refine calculus tools. Blasco Lucas et al. [7] compared physical models of massive/Trombe walls and direct gain, sunspace and traditional buildings in order to establish the convenience of passive systems considering their thermal performance, finding that special care must be given to implementation of ventilation and incorporation of efficient protection. Similar results were found by Fernández-Gonzáles [8] for United States Midwest climate conditions, with special emphasis on human inner thermal comfort conditions. Several works analyse the performance of dynamic energy modeling on glazed spaces validating their assumptions on full-scale experimental data [9,10], often finding a good approximation of results of the model and of the measurements, even if proposing different approaches. Other researches focus on achieving an effective simulation of solar radiation distribution and reflection inside the sunspace [11,12,13] that remains one of the key central point of dynamic simulations.
Two recent papers show that passive solar systems, and sunspaces in particular, are still nowadays strongly considered as appropriate systems for building heating, Ignjatović et al. [14] and Rempel et al. [15]. The former refers about the first building in Serbia that received the permission to apply a sunspace as an efficient strategy for energy saving. The latter concerns a deep investigation of the effect of thermal mass as heating storage in sunspaces, so to give users and designers (enthusiastic of sunspaces but usually wary of unproven systems) guidelines for contemporary passive solar design.
The usefulness of a passive approach to building design in order to decrease energy need, the use of non-renewables and the emission of greenhouse gases in the atmosphere, are now also recognized by international legislature. Annex I of European Directive 2010/31/EU [16] states that passive solar systems must be taken into consideration in the building energy performance calculation procedure. The 32th preamble of the European Directive 2009/28/EC [17] states that “passive energy systems use building design to harness energy”, meaning that concepts related to energy efficiency and to renewable energy exploitation are integrated in the architectural design. Besides, public authorities are now taking into consideration the possibility of including solar systems in urban planning tools, providing incentives for their use and considering them as technical volumes [18].
Nevertheless, dynamic simulation software generally gives several uncertainties on the proper evaluation of radiation through glasses and multi-reflection in closed spaces, depending also on the complexity of the building shape [19,20]. Furthermore, software packages for dynamic simulation are not user friendly, they require several input data, often unknown even by the designers, and sometimes the interpretation of outputs requires specific knowledge, so quasi steady-state procedures are often used in everyday practice with good results. Annex E of EN ISO 13790:2008 [21] provides procedures for calculating the heat transfer and solar heat gains of special elements, such as unconditioned sunspaces. This methodology has been successfully included in several software packages approved by national certification bodies and so it is widely used by practitioners. Anyway, some aspects of the Standard can be improved: calculation of direct and indirect solar heat gains [22], solar absorption factor in the sunspace [23], the correction factor Fw of solar gains through glazed surfaces [24], the shading factor (influencing direct heat gains), indirect heat gains [25] and ventilation through the sunspace are considered the more relevant ones.
Moreover, the Energy Efficiency Directive [26] introduces an important new dimension to the energy saving in buildings legislative landscape. “Article 4 requires Member States, for the first time, to set out national strategies for the renovation of their building stocks, thereby filling a major gap in policy concerning the existing building stock” [27]. It is with this in mind that the authors propose the work described herein.

2. Aim of the Paper

In this paper, a comparative analysis of different solutions for the construction of verandas (which can be considered as sunspaces with an opaque envelope integrated in the building structure and some large glazed surfaces exposed to external environment) in an existing building is presented, following the procedure provided by EN ISO 13790. Some changes to the standard have been suggested to better consider the ventilation through the sunspace and provide a more accurate description of indirect gains. The aim is to highlight the possibility to use sunspaces in order to increase energy efficiency of the existing building stock, considering ease of construction and economic viability.

Improvement of Annex E of EN ISO 13790

The calculus methodology presented in EN ISO 13790 is based on quasi-steady-state models, taking into account heat transfer plus solar and internal heat gains reduced by a utilization factor, also considering the thermal inertia of the building. The general equation is as follows:
Q H , nd   =   Q H , ht     η H , gn   Q H , gn   [ MJ ]
where QH,nd is the building energy need for continuous heating, QH,ht is the heat transfer from inside to outside (losses), ηH,gn is the dimensionless gain utilization factor, QH,gn is the total heat gain (typically solar radiation and internal gains over the given period).
Generally, quasi-steady-state methods are used with monthly calculations. The logic behind Annex E of EN ISO 13790 is that the sunspace is considered as a general unheated space adjacent to a conditioned space, whose temperature is higher than the external one because of the buffer effect. The solar heat gain entering the conditioned space from the sunspace, Qss, is considered as the sum of two factors:
  • the direct gain Qsd through the wall which divides the heated space from the sunspace (both transparent and opaque parts);
  • the indirect gain Qsi relative to the temperature increase of the sunspace (Qsi can be considered as the increase of the buffer effect due to solar radiation).
Readers should refer to Annex E of the European Standard for a detailed analysis of the methodology, which is out of the scope of this work.
Besides the improvements already discussed in the Introduction [22,23,24,25], a further one for the analysis of ventilation through the sunspace (related to factor Qsi) is proposed here, an issue that will be important in the following discussion. Annex E states that “if there is a permanent opening between the conditioned space and the sunspace, it shall be considered as part of the conditioned space”. Considering the typical situation of a veranda, if a constant mechanical air extraction is provided in the internal rooms, with a resulting air flow crossing the sunspace, according to Annex E the veranda should be considered as part of the conditioned space (Figure 1). This is an approximation, because during winter the resulting ventilation from outside to inside would increase the temperature difference between the sunspace and the internal environment. Therefore, we are facing a paradox: when thermal losses are considered and no ventilation is present, according to the Standard the sunspace temperature is lower than indoor one; if ventilation is provided (mechanical or not), the sunspace suddenly becomes part of the indoor environment, although its temperature probably drops more than without ventilation (in winter conditions). The problem is that an accurate calculation of the ventilation losses should take into account the amount of heat absorbed by the air from the sunspace. Therefore, a correct analysis should consider with high precision the convective exchange coefficients, the air stratification, the geometric position of inlet and outlet and so on. Computational fluid dynamic simulations would be necessary, and the quasi-steady state method proposed by the Standard seems difficult to use. Anyway, a simplified but effective approach can be considered, with the hypothesis of uniformity of the air temperature inside the sunspace (“perfect mixing”), although in real condition of use temperature within the sunspace has both geometrical and temporal gradients depending also on the users habits.
According to the first law of thermodynamics in stationary conditions, with negligible variations of the kinetic and potential energy and in conditions of no useful work, the heat exchanged and the variation in enthalpy are the same:
Q ˙ a b s +   H i u , t r ( T i T u ) + H u e , t r ( T e T u ) =   m ˙ ( h u h e )   [ W ]
where Q ˙ abs is the solar radiation absorbed by the sunspace and contributing to the temperature increase, Hi-u,tr is the heat transfer coefficient between the veranda and the indoor environment, Hu-e,tr is the heat transfer coefficient between the veranda and the external environment, Tu is the inner air temperature, Te is the outer air temperature, ṁ is the air flow, hu and he are the enthalpy within and outside the veranda respectively.
Considering the average specific humidity inside the veranda as equal to the average specific humidity outside the veranda, the following equation for ideal gas can be used as first approximation:
h u h e = c a ( T u T e )   [ J / kgK ]
where ca is the specific heat of dry air.
Substituting Equation (3) in Equation (2) and solving the equation considering the veranda mean temperature Tu, we find:
T u = ( Q ˙ a b s + H i u . t r T i + H u e , t r T e + m ˙ c a T e ) H i u , t r + H u e , t r + m ˙ c a   [ K ]
So, the temperature increase due to solar radiation can be expressed as:
T u = Q ˙ a b s H i u , t r + H u e , t r + m c ˙ a   [ K ]
The total indirect heat gain is:
Q s i = Q s i , t r + Q s i , v e = ( H i u , t r + m c ˙ a ) T u   [ MJ ]
where:
Q s i , t r = H i u , t r T u   [ MJ ]
is the reduction of the heat conduction from the heated space to the veranda, and:
Q s i , v e = m c ˙ a T u   [ MJ ]
is the decrease of ventilation losses from the indoor environment.
Finally, considering Equation (5), Qsi can be calculated as:
Q s i = ( H i u , t r + m c ˙ a ) Q ˙ a b s ( H i u , t r + H u e , t r + m c ˙ a )   [ MJ ]

3. Methods

In order to assess the possibility and the viability of using verandas in the building renovation process as passive solar elements, the improved EN ISO 13790 calculation methodology has been applied to a real case study: the refurbishment of a building for social housing in Freiburg, in the Weingarten West area, part of a specific plan called “Weingarten 2020” [28] (Figure 2). The aim of the plan was to reduce the actual demand for energy consumption of the district by 30% and to propose a sustainable model for energy urban renovation. In particular, a typical apartment of a linear building has been considered, consisting of a living room, a kitchen, a bathroom, two bedrooms and a veranda adjacent to the sitting room and to the single bedroom. This building typology is typical of social housing constructions from the sixties and the seventies all over Europe, when the need to give a roof to several families in short time was pressing (Figure 3). Now, new building energy regulations force for deep renovation, and the maintenance of the original typology but with glazed verandas is a viable option.
A procedure has been set up with the goal of comparing the existing poorly insulated situation with possible renovation strategies, gradually more complex and sophisticated.
In particular, the energy performance of the veranda in the following configuration has been evaluated (please refer to Figure 4):
-
V1: as built situation, no external glazing, double glazed internal window and natural ventilation;
-
V2: no external glazing, double glazed internal window, insulation of the walls and natural ventilation;
-
V3: single glazed window, triple glazed internal window, insulation of the walls (veranda + outer) and of the guard, mechanical ventilation;
-
V4: double glazed veranda window, double glazed internal window, insulation of the walls (outer) and of the guard, mechanical ventilation;
-
V5: like V4 but with single glazed veranda window and triple glazed internal window;
-
V6: with no veranda, triple glazed window and natural ventilation;
-
V7: like V4, but with no guard and a wide double glazed window;
-
V8: like V7, but with insulation of the veranda walls;
-
V9: like V8, but with a mechanical ventilation system in the veranda, with heat recovery;
-
V10: like V9, but with a heat exchanger bypassing the veranda;
-
V11: like V9 but with no veranda;
-
V12: like V8 but with natural ventilation.
The main idea is to start with basic configurations whose difference is just in the envelope insulation values (V3–V5), to implement a wide transparent element in place of the opaque guard (in order to exploit solar radiation) and, finally, to evaluate different ventilation systems. Two versions with no veranda at all (V6 and V11) has been considered just as reference cases. Thermal properties of the elements considered in the different configurations are presented in Table 1. Thermal transmittance U values of the opaque and transparent elements have been calculated following Standard EN ISO 6946:2007 [29] and EN ISO 10077:2006 [30] respectively.
Thermal bridges have been evaluated as well, with a finite element method (FEM) calculation according to EN ISO 10211:2007 [31]. The FEM calculation was particularly important to evaluate the heat losses through the corners between indoor and external environments as well as the veranda. In fact, heat losses from inner space to the veranda contribute to the buffer effect, while those through the external walls are completely lost: these two aspects must be considered separately. For simplification purposes, symbols of thermal bridges are reported in Figure 4.

Introduction to Calculations

Calculations were performed following EN ISO 13790 and Annex E improved as previously discussed, by means of simulation programs improved by the authors with a spreadsheet concerning what was previously exposed in Section 2. The period considered is the heating season, going from the 15th of October to the 15th of April.
The required primary energy is calculated as the sum of the boiler fuel requirements and the electrical energy. A conversion factor of 1.1 for the thermal energy and of 2.7 for the electrical energy was considered. The indoor environment ventilation rate was set to 0.42 L/s/m2 as suggested in EN ISO 15251:2008—Table B5 for buildings of category II [32]. Half the ventilation rate was supposed to pass through the veranda for the cases with mechanical extraction, while the whole rate is considered if a mechanical supply system is present. The electrical requirements due to exhaust ventilation were fixed to 0.15 Wh/m3 in case of simple forced air extraction, 0.30 Wh/m3 in case of a complete mechanical ventilation system. The efficiency coefficient of heat recovery was supposed to be 0.75.
Annex E procedure for the calculation of indirect heat gains does not take into account the contribution from the heat absorbed by the sunspace after multiple reflections. Therefore, the absorbed heat is underestimated. Anyway, when in the different configurations a guard is present, the heat absorbed after reflections is not negligible and it was considered as follows:
Q a b s , a m r = h g r d h t o t Q r a d , e n t Q a b s , d i r   [ MJ ]
where hgrd is the height of the opaque guard, htot is the total height of the veranda, Qrad,ent is the fraction of the total solar radiation entering the veranda not passing directly to the indoor environment through the window, Qabs,dir is the total radiation directly absorbed by the veranda (according to equation E.3 of Annex E minus the heat transmitted through opaque walls to the indoor environment).
Finally, the total radiation absorbed by the veranda is:
Q a b s = Q a b s , d i r + Q a b s , a m r   [ MJ ]
The condition that solar radiation adsorbed by internal surfaces cannot be higher than the one entering the veranda was imposed. It can be considered as a check for the calculation, especially for the shading factor. Shading factors were estimated according to the German technical standard DIN V 18599-1:2011 [33], as functions of obstacles (frontal, vertical, horizontal), exposure, shading angle, and season.

4. Results and Discussion

In order to compare the different configurations under investigation, the following parameters have been considered:
-
Hi-e,tr (W/K) is the transmission heat transfer coefficient between indoor and external environment;
-
Hi-e,ve (W/K) is the ventilation heat transfer coefficient between indoor and external environment;
-
Hi-e (W/K) is the total heat transfer coefficient between indoor and external environment;
-
f is the transmission factor through the veranda;
-
Sp.H.D. (kWh/m2y) is the specific heat demand;
-
H.D. (kWh/y) is the heat demand;
-
Sp.Pr.En.H.V. (kWh/m2y) is the specific primary energy for heating and mechanical ventilation;
-
Pr.En.H.V. (kWh/y) is the primary energy for heating and mechanical ventilation.
Results are presented in Table 2.
Hi-e means the total thermal load lost to the environment, the sum of transmission Hi-e,tr and ventilation Hi-e,ve heat transfer coefficients. Please note that Hi-e,tr also takes into consideration the heat transfer through unconditioned spaces, following EN ISO 13790 and EN ISO 13789:2007 [34]. Therefore, it depends on f, which is the ratio between the temperature difference between indoor environment (Ti) and veranda (Tu), and the temperature difference between indoor and external environment (Te):
f = T i T u T i T e
Since the airflow through the veranda directly influences the transmission factor, Hi-e,tr is also influenced by ventilation.
Finally, the heat demand and the primary energy for heating are reported to give an indication of the total heating requirements. The specific values have been added so to facilitate comparison with similar cases but with different floor areas, if needed (configurations V6 and V11).
Of course, being configuration V1 the basic one, it is the most energy demanding. Calculations highlight that just by adding an external insulation layer (configuration V2), the heat demand decreases by more than the 70%, thus confirming the importance of a good insulated envelope; the specific heat demand drops to 45 kWh/m2y (of course, the ventilation heat transfer coefficient does not change while the transmission one does), and the building now falls into the low energy consumption building category. But working now specifically on the veranda, closing it to the outside with a single glass window, considering a mechanical air extraction system and insulating the guard (V3), the heat demand becomes about 15% of the initial one and approximately the half of V2. In this case, both transmission and ventilation heat transfer coefficient have been improved. Configurations V4 and V5, where the insulation of the veranda internal walls is removed but a high performance external window is installed (a double and a triple glazed window respectively), have a better energy performance (between 10% and 13%) due to the increased air ventilation temperature. In fact, the f value is respectively 31% and 22% of that of the previous V3 configuration. This means that, considering ventilation, the best solutions are the ones with a low transmission factor through the veranda, meaning that the average temperature value in the veranda is close to the indoor temperature, even if solar radiation is not considered. Anyway, just for this reason these solutions could have practical limitations on the heat management side during intermediate seasons (spring and autumn). In fact, in order to avoid overheating during the warmest hours of the day, the user can decide to open the external window, thus decreasing the thermal resistance between the veranda and the external environment. If not properly managed, a problem of excessive thermal losses could occur during the evening, when external temperature decreases and sun radiation power is low or absent. Finally, the indoor environment could require the intervention of the heating system to raise inner temperature values, increasing the building heat demand more than designed.
A step forward is the increase of incoming solar radiation, considering the panel between the veranda and the external environment completely glazed, that is no opaque guard and a unique wide double glaze window (V7). In this configuration, even if the thermal resistance of the panel is lower than in the previous ones where the guard was highly insulated and the heat transmission for ventilation is largely unchanged, the heat demand further decreases of another 15% approaching the passive house solution (18.9 kWh/m2y vs. 15 kWh/m2y required by the passive standard). Solar gains definitely balance thermal losses. In order to avoid the abovementioned uncontrolled heat losses during intermediate seasons, a configuration with a minimum of 5 cm insulation on the walls separating the veranda from indoor environment is proposed (V8). The energy performance is good and very similar to the previous one (being the best configuration without heat recovery), but the behavior of the veranda would probably be highly performing in real use conditions during intermediate seasons, and calculation results would be better met.
Generally speaking, from an energy point of view the advantage of a veranda is that it serves as a buffer space between the main part of the building and the external environment. A great part of the energy savings are due to this buffer effect, increasing the thermal resistance towards the outside and preheating the ventilation air from the outside. On the other hand, a large window with no veranda (V6) allows direct heat gains and increases the conditioned living space, useful if a bigger room is required. Anyway, it can be noticed that the energy performance in such configuration is not particularly high: heat demand is approximately 6% higher than for V4. In addition, it is economically disadvantageous when refurbishing a building where verandas already exists. Moreover, user psychology and comfort must be taken into account: verandas realize a living space of high quality that can be used during colder seasons as a protected external environment, so they are often highly appreciated, especially in cold climates.
Another improvement to the proposed solution is the introduction of a heat exchanger (V9). In fact, considering the high wall thermal resistance value (U = 0.17 W/m2K), the heat transmission coefficient is very low and we can try to decrease energy demand working on the ventilation losses. Comparing configuration V8 and V9, the ventilation heat transfer coefficient decreases by approximately 63% and the heating demand is very low, with a specific value lower than 4 kWh/m2y. Anyway, this solution, certainly interesting from an energy point of view, is economically more expensive in the short term and a wrong management of the veranda can waste the usefulness of the system (acting on the ventilation air passing through the veranda itself): for example, if the user opens the window between the veranda and the external environment. This problem can be avoided bypassing the veranda (V10): the theoretical increase in energy demand is about 7% but the real energy requirement of V9, with a wrong management of the window openings, could be even higher. Again, considering a solution with high thermal insulation of the envelope and a controlled ventilation with heat recovery but without any veranda (V11), apart from the considerations previously made, the energy performance clearly gets worse, with the heat demand increasing by about 40% compared to V10.
Finally, considering economical, managerial and psychological reasons, configuration V8 is probably the most effective. If a solution with no electrical energy use is required in order to approach a real passive architecture system, we can decide to avoid the air extraction system (V12). In this case, anyway, the heat demand increases by 26% while the total primary energy coefficient for heating and mechanical ventilation increases by 11%.

5. Conclusions

Nowadays sunspaces are architectural elements still highly appreciated by users and can be properly considered during the renovation design process in order to decrease the existing building energy demand. International legislation as well as local ones clearly push in this direction and also provide economic incentives in many instances. Research on this topic, being mostly qualitative in the seventies, now have a new impetus considering both energy and comfort aspects, and concern the monitoring of the performance of real scale models as well as the development of a complex calculus methodology in dynamic conditions. Anyway, numerical predictions of passive element performance, even if necessary, are generally performed with quasi-steady state methodology in everyday practice, being easier to use, faster and giving good precision during the heating season, above all when parametric comparison is required.
For this reason, in this paper a further improvement of Annex E of EN ISO 13790 on the energy performance calculation of sunspaces is proposed, specifically on the ventilation losses through the sunspace (besides the ones discussed in recent scientific literature on related aspects). The improved methodology has been applied to evaluate a possible refurbishment of a building for social housing in Freiburg (Germany), where the verandas could be used as passive solar elements in order to increase the overall energy efficiency of the intervention. Several configurations of increasing complexity have been proposed, concerning the proper design of insulating materials, window dimensions (and so solar direct gains), mechanical ventilation and heat exchangers. Advantages and disadvantages have been discussed so that a general model of intervention has been proposed: Good insulation of the building envelope (veranda walls included), no guard but a wide window in order to exploit solar direct gains, a mechanical ventilation system in order to preheat the supplied air enhancing the buffer effect (configuration V8).
Several buildings built around Europe for social housing purposes have been designed following a similar typology during the sixties and seventies, with compact shape but very poor envelope thermal resistance and wide verandas facing south- or westward. The simple but effective methodology presented in this paper is considered as a guideline for practitioners in order to propose suitable and reliable interventions on the existing building stock that can meet the new energy requirements stressed by the European Directives.
Indeed, future developments should consider in depth the ventilation modes between the external environment, veranda and indoor rooms being air ventilation and preheating effects important to control the efficiency of the system. Of course, quasi-steady-state models will be no more reliable, and a CFD simulation becomes necessary. Furthermore, an LCA analysis considering also economical aspects (LCC analysis) could give interesting insights into the overall benefits of the different configurations proposed.

Acknowledgments

The research presented in this paper is the result of a collaboration between the Fraunhofer-Institut für Solare Energiesysteme ISE (Freiburg, Germany) and the Department of Civil Environmental and Mechanical Engineering of the University of Trento (Italy). The authors would like to thank Florian Kagerer, former researcher at ISE, for his valuable contributions.

Author Contributions

All authors have participated in preparing the research from the beginning to the end, such as establishing research design, method and analysis. All authors discussed and finalized the analysis results to prepare manuscript according to the progress of research.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mazria, E. The Passive Solar Energy Book, 1st ed.; Rodale Press: Emmaus, PA, USA, 1979. [Google Scholar]
  2. Steven Winter Associates. The Passive Solar Design and Construction Handbook; Crosbie, M.J., Ed.; Wiley: New York, NY, USA, 1998. [Google Scholar]
  3. Hastings, R. Myths in passive solar design. Sol. Energy 1995, 55, 445–451. [Google Scholar] [CrossRef]
  4. Wall, M. Climate Energy Use in Glazed Spaces. Ph.D. Thesis, Department of Building Science, Lund University, Lund, Sweden, 1996. [Google Scholar]
  5. Mihalakakou, G.; Ferrante, A. Energy conservation and potential of a sunspace: Sensitivity analysis. Energy Convers. Manag. 2000, 41, 1247–1264. [Google Scholar] [CrossRef]
  6. Mihalakakou, G. On the use of sunspace for space heating/cooling in Europe. Renew. Energy 2002, 26, 415–429. [Google Scholar] [CrossRef]
  7. Blasco Lucas, I.; Hoesé, L.; Pontoriero, D. Experimental study of passive systems thermal performance. Renew. Energy 2000, 19, 39–45. [Google Scholar] [CrossRef]
  8. Fernández-Gonzáles, A. Analysis of the thermal performance and comfort conditions produced by five different passive solar heating strategies in the United States Midwest. Sol. Energy 2007, 81, 581–593. [Google Scholar] [CrossRef]
  9. Roux, J.J.; Teodosiu, C.; Covalet, D.; Chareille, R. Validation of a glazed space simulation model using full-scale experimental data. Energy Build. 2004, 36, 557–565. [Google Scholar] [CrossRef]
  10. Mottard, J.M.; Fissore, A. Thermal simulation of an attached sunspace and its experimental validation. Sol. Energy 2007, 81, 305–315. [Google Scholar] [CrossRef]
  11. Oliveti, G.; De Simone, M.; Ruffolo, S. Evaluation of the absorption coefficient for solar radiation in sunspaces and windowed rooms. Sol. Energy 2008, 83, 212–219. [Google Scholar] [CrossRef]
  12. Oliveti, G.; Arcuri, N.; De Simone, M.; Bruno, R. Solar heat gains and operative temperature in attached sunspaces. Renew. Energy 2012, 39, 241–249. [Google Scholar] [CrossRef]
  13. Bataineh, K.M.; Fayez, N. Analysis of thermal performance of building attached sunspace. Energy Build. 2011, 43, 1863–1868. [Google Scholar] [CrossRef]
  14. Ignjatović, D.; Popović, M.J.; Kavran, J. Application of sunspaces in fostering energy efficiency and economical viability of residential buildings in Serbia. Energy Build. 2015, 98, 3–9. [Google Scholar] [CrossRef]
  15. Rempel, A.R.; Rempel, A.W.; Gates, K.R.; Shaw, B. Climate-responsive thermal mass design for Pacific Northwest. Renew. Energy 2016, 85, 981–993. [Google Scholar] [CrossRef]
  16. European Union. Directive 31 of the European Parliament and of the Council of 19 May 2010 on the Energy Performance of Buildings (Recast); European Union: Brussels, Belgium, 2010. [Google Scholar]
  17. European Union. Directive 28 of the European Parliament and of the Council of 23 April 2009 on the Promotion of the Use of Energy from Renewable Sources; European Union: Brussels, Belgium, 2009. [Google Scholar]
  18. The Regional Council of Lombardy. Updating of Regional Rules on Energy Efficiency and Energy Certification for the Recognition of Bioclimatic Function of Sunspaces and Loggias to be Considered as Technical Volumes; The Regional Council of Lombardy: Milan, Italy, 2014. (In Italian) [Google Scholar]
  19. Voeltzel, A. Thermal and ventilation modelling of large highly-glazed spaces. Energy Build. 2001, 33, 121–132. [Google Scholar] [CrossRef]
  20. EnergyPlus Documentation—Input output Reference. Available online: https://energyplus.net/sites/default/files/pdfs/pdfs_v8.3.0/InputOutputReference.pdf (accessed on 16 January 2016).
  21. Energy Performance of Buildings—Calculation of Energy Use for Space Heating and Cooling—Annex E: Heat Transfer and Solar Heat Gains of Special Elements; ISO 13790:2008(en); International Organization for Standardization: Geneva, Switzerland, 2008.
  22. Passerini, F.; Albatici, R.; Frattari, A. Quasi-steady state calculation method for energy contribution of sunspaces: A proposal for the European standard improvement. In Proceeding of the Building Simulation Applications (BSA2013), Bolzano, Italy, 30 January–1 February 2013; pp. 141–150.
  23. Oliveti, G.; Arcuri, N.; Bruno, N.; De Simone, M. An accurate calculation model of solar heat gain through glazed surfaces. Energy Build. 2001, 43, 269–274. [Google Scholar] [CrossRef]
  24. Bruno, R.; Oliveti, G.; Arcuri, N. An Analytical model for the evaluation of the correction factor Fw of solar gains through glazed surfaces defined in EN ISO 13790. Energy Build. 2015, 96, 1–19. [Google Scholar] [CrossRef]
  25. Oliveira Panão, M.J.N.; Camelo, S.M.L.; Gonçalves, H.J.P. Solar Load Ratio and ISO 13790 methodologies: Indirect gains from sunspaces. Energy Build. 2012, 51, 212–222. [Google Scholar] [CrossRef]
  26. European Union. Directive 27 of the European Parliament and of the Council of 25 October 2012 on Energy Efficiency; European Union: Brussels, Belgium, 2012. [Google Scholar]
  27. Staniaszek, D. Renovation Strategies of Selected EU Countries—A Status Report on Compliance with Article 4 of the Energy Efficiency Directive; Buildings Performance Institute Europe (BPIE): Brussels, Belgium, 2014. [Google Scholar]
  28. Modellhafte Stadtquartierssanierung Freiburg Weingarten-West. Available online: http://www.eneff-stadt.info/de/pilotprojekte/projekt/details/modellhafte-stadtquartierssanierung-freiburg-weingarten-west/ (accessed on 20 January 2016). (In German)
  29. Building Components and Building Elements—Thermal Resistance and Thermal Transmittance—Calculation Method; ISO/DIS 6946; International Organization for Standardization: Geneva, Switzerland, 2007.
  30. Thermal Performance of Windows, Doors and Shutters—Calculation of Thermal Transmittance—Part 1; EN ISO 10077; International Organization for Standardization: Geneva, Switzerland, 2006.
  31. Thermal Bridges in Building Construction—Heat Flows and Surface Temperatures—Detailed Calculations; EN ISO 10211; International Organization for Standardization: Geneva, Switzerland, 2007.
  32. Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics; EN ISO 15251; International Organization for Standardization: Geneva, Switzerland, 2008.
  33. Energy Efficiency of buildings—Calculation of the Net, Final and Primary Energy Demand for Heating, Cooling, Ventilation, Domestic Hot Water and Lighting—Part 1: General Balancing Procedures, Terms and Definitions, Zoning and Evaluation of Energy Sources; DIN V 18599-1; Deutsches Institut Fur Normung: Berlin, Germany, 2011.
  34. Thermal Performance of Buildings—Transmission and Ventilation Heat Transfer Coefficients—Calculation Method; EN ISO 13789:2007; International Organization for Standardization: Geneva, Switzerland, 2007.
Figure 1. Scheme of operation of the veranda with mechanical air extraction equipment.
Figure 1. Scheme of operation of the veranda with mechanical air extraction equipment.
Energies 09 00365 g001
Figure 2. The building under renovation in the Weingarten West area of Freiburg (Germany).
Figure 2. The building under renovation in the Weingarten West area of Freiburg (Germany).
Energies 09 00365 g002
Figure 3. Buildings from the seventies with similar typology: (a) In Trento (Italy); (b) In Kosize (Slovak Republic).
Figure 3. Buildings from the seventies with similar typology: (a) In Trento (Italy); (b) In Kosize (Slovak Republic).
Energies 09 00365 g003
Figure 4. Scheme of the different veranda configuration evaluated, where yellow hatch is the thermal insulation, arrow is the mechanical ventilation (extraction), red circle is the corner thermal bridge, blue circle is the slab thermal bridge.
Figure 4. Scheme of the different veranda configuration evaluated, where yellow hatch is the thermal insulation, arrow is the mechanical ventilation (extraction), red circle is the corner thermal bridge, blue circle is the slab thermal bridge.
Energies 09 00365 g004
Table 1. Thermal properties of the elements considered in the different verandas configurations.
Table 1. Thermal properties of the elements considered in the different verandas configurations.
ElementSymbolU (W/m2K)gΨ (W/mK)
Original wallW13.15-
Wall 5 cm insulationW20.57-
Wall 20 cm insulationW30.17-
Original windowG12.800.77
Single glazed windowG25.800.87
Double glazed windowG31.300.64
Triple glazed windowG40.660.47
Thermal bridge 1TB1--1.00
Thermal bridge 2TB2--1.45
Thermal bridge 3TB3--−0.50
Thermal bridge 4TB4--0.50
Thermal bridge 5TB5--0.02
Thermal bridge 6TB6--−0.05
Thermal bridge 7TB7--−0.02
Thermal bridge 8TB8--−1.20
Thermal bridge 9TB9--0.00
Thermal bridge 10TB10--−0.10
Thermal bridge 11TB11--0.70
Table 2. Energy performance of the different verandas configurations.
Table 2. Energy performance of the different verandas configurations.
ConfigHi-e,trHi-e,veHi-efSp.H.D.H.D.Sp.Pr.En.H.V.Pr.En.H.V.
(W/K)(W/K)(W/K)%(kWh/m2y)(kWh/y)(kWh/m2y)(kWh/y)
V1134.127.3161.7-169.59523.4204.211,478.5
V229.627.357.0-45.32547.059.13319.4
V320.024.944.982.125.61437.136.72026.6
V427.917.245.125.722.01234.531.31760.7
V526.916.243.118.322.31250.831.81785.3
V616.927.544.5-22.11368.730.11862.6
V729.317.546.828.218.91060.027.21529.4
V822.921.344.155.617.7995.426.11465.0
V918.47.926.429.13.9216.910.6595.4
V1019.18.327.433.14.0222.911.3635.0
V1116.99.826.7-5.0310.012.9793.7
V1220.725.446.142.822.41257.029.11632.2

Share and Cite

MDPI and ACS Style

Albatici, R.; Passerini, F.; Pfafferott, J. Energy Performance of Verandas in the Building Retrofit Process. Energies 2016, 9, 365. https://doi.org/10.3390/en9050365

AMA Style

Albatici R, Passerini F, Pfafferott J. Energy Performance of Verandas in the Building Retrofit Process. Energies. 2016; 9(5):365. https://doi.org/10.3390/en9050365

Chicago/Turabian Style