Next Article in Journal
Impact of Perceived Livelihood Risk on Livelihood Strategies: A Case Study in Shiyang River Basin, China
Next Article in Special Issue
Capital Structure of Public–Private Partnership Projects: A Sustainability Perspective
Previous Article in Journal
Theoretical Study of an Intermittent Water-Ammonia Absorption Solar System for Small Power Ice Production
Previous Article in Special Issue
Sustainable Development of Urban Rail Transit Networks: A Vulnerability Perspective
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Mechanical Properties of New Dry-Type Beam-Column Bolt Connection Joint

1
Department of Civil Engineering, Anhui Jianzhu University, Hefei 230601, China
2
Department of Civil Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China
3
School of Computing, Engineering and Mathematics, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia
4
College of Civil Engineering, Shenzhen University, Shenzhen 518000, China
*
Author to whom correspondence should be addressed.
Sustainability 2019, 11(12), 3348; https://doi.org/10.3390/su11123348
Submission received: 12 May 2019 / Revised: 11 June 2019 / Accepted: 13 June 2019 / Published: 17 June 2019

Abstract

:
Beam–column assembled joint connections are crucial for realizing the industrialization of buildings through prefabrication. This paper focuses on the mechanical properties of a new dry-type high-strength bolt connection joint used in prefabricated buildings. The structural performance properties examined include bearing capacity, stiffness, failure mode, energy dissipation capacity, and deformation performance, all of which are tested through a pseudo static test involving low-cycle repeated loading. The test results show that the failure of the new dry-type beam–column connection joint is through plastic failure, with full hysteretic curve and good energy dissipation performance. The results provide a foundation for the analysis of assembled structural framework systems based on different forms of dry-type connection joints.

1. Introduction

Construction is an important industry for many countries economy as it contributes mostly to their GDP. Prefabrication is an “umbrella” term and it covers a range of different systems and processes. These will include structural, architectural and services elements. It was also mentioned to as offsite construction or modular construction where building components are manufactured and assembled in a plant instead of the construction site before the final building. Prefab can be categorized into components, panels (2D), modules (3D), hybrids, and unitized whole buildings [1]. It is recognized by both design and construction professionals as one of the most common methods where the benefits include its facilitation towards achieving high quality construction, reducing health and safety risks, improving in planning, control, and innovation environments, as well as, facilitating organizations to be more successful preventing injuries particularly related to hazards of sustainable elements such as “construction at height, overhead, with energized electrical systems, and in confined spaces” [2,3].
Prefabrication is regarded as the most efficient way to achieve building industrialization and green buildings in China. This is due to its socio-economic and environmental benefits, including a large saving of construction time, better quality control and engineering performance, less construction and demolition waste, and less pollution [4,5,6]. This construction method has been widely adopted in China’s building industry. The design of beam–column joints is the most complex and critical in the whole prefabricated building system. The joint is usually the most fragile member of the whole structural system and the failure of joints often leads to the failure of the whole structure. The connection mode of beam–column joints is therefore key to the whole prefabricated structural system. Dry-type connection joints are the latest development [7,8,9,10].
There has been a plethora of research on prefabricated concrete member joints for industrialized buildings. Huang [11] compared the advantages and disadvantages of dry connections, and improved various dry-type connection joints, providing a basis for future related research. Yan [12] conducted the reversed cyclic loading test on two precast prestressed concrete beam–column joints that were fabricated with two different concrete strengths in the keyway area. Ousalem [13] conducted the low-cycle repeated loading tests on precast high-strength concrete structures. Precast beams were spliced and connected by bolts in the span. The results showed that a plastic hinge would form at the beam end under the action of low-cycle repeated loading, while the stiffness, strength, and other properties at the bolt joint were better, and no plastic hinge was formed. Cheng [14] designed the middle joints of prefabricated partial steel-reinforced concrete frame beams and columns and tested the failure patterns and hysteretic curves under the action of low-cycle repeated loading. Choi [15] studied the new type of assembled ductile joint by repeated loading tests. Nzabonimpa [16] proposed the dry-type mechanical beam–column connection joint for fully-restrained bending moment connection of concrete components. Through tests, analysis, and research, the structural performance of the dry-type connection joint was verified, and the parameters affecting the performance of the dry-type mechanical bending moment concrete joint were determined. Other scholars have also further studied dry-type connection joints [17,18,19,20,21].
Based on a review of the literature related to prefabricated beam–column joints, this paper aims to: (1) propose a feasible prefabricated concrete frame structure system with energy-dissipating members, (2) design a new dry-type high-strength bolted joint, and (3) study the joint’s failure mode and mechanical performance by means of a pseudo-static experiment. The experiment provides a basis for analyzing the performance of the new joint by comparison with several other dry-type connection joints. The research results not only provide experimental basis for the further prefabrication applications in particular but also contribute to construction’s sustainability in general.

2. New Dry-Type Connection Joint

Considering that the new joint connection method is used in conjunction with the energy-consuming component, the joint is required to have a large deformation. Therefore, the test components for this study are taken from the assembled 3 × 6 frame structure, without secondary beams, and with a standard column span of 8.4 m and floor height of 4.2 m (see Figure 1). The concrete grade of the 750 mm × 750 mm column is C80, the concrete grade of the 400 mm × 750 mm beam is C40, and the rebar grade is HRB400. Eight grade 8.8 high-strength bolts with a diameter of 30 mm are used as semi-rigid joints for connection (see Figure 2 and Figure 3), with the joint stiffness coefficient of 0.5 and a theoretical ultimate bending moment of 456 kN·m/m.
The strength grade of concrete of column and beam are C80 and C40 respectively. The strength grade of stirrup of beam and column are both HPB300 when the strength grade of longitudinal reinforcement is HRB400. The strength grade of bolt is 8.8. Before the experiments, tests of material properties for concrete, steel bars, and bolt are conducted at materials mechanics laboratory. Each batch of concrete is reserved with 9 test blocks with a size of 150 mm × 150 mm × 150 mm. 3 days, 7 days, and 28 days of on-site maintenance are carried out, respectively. Compressive tests were carried out in accordance with the standard of mechanical properties test method of ordinary concrete (GB/T50081-2002). The measured compressive strength results of concrete cubes are shown in Table 1.
Three samples were selected from each batch of reinforcement bars and bolts for tensile test. The measured yield strength, tensile strength, and elongation of reinforcement bars and bolts are shown in Table 2.

3. Tests Process

3.1. Specimen

The production of prefabricated beams and columns was completed in the Building Structure and Underground Engineering Laboratory. The production and installation procedures of the specimens were as follows (see Figure 4).
Step 1: Experimental preparation
The first step was to prepare wooden formwork of good texture, hardness, and no distortion, and soak it with water. The necessary reinforcement material was then positioned in accordance with the construction drawings. High-strength bolts were then located on the surface of the beam and column, and strain measurement gauges attached to the reinforcement bars for experimental purposes. In the latter process, the part of the bar where the gauge was to be fixed was ground smooth with a grinder and the surface cleaned with anhydrous alcohol. Cyanoacrylate 502 instant aadhesive was applied to the polished part of the strain gauge and it was wrapped with rubber and waterproof tape. The outside was covered with cotton cloth over which epoxy resin was evenly applied and then fastened with a plastic strip. Finally, the strain gauges were numbered and labelled after being wired. The gauges were checked at the same hour of the day on daily base to see if the wire was still energized in case there had been a short circuit that would impede the smooth progress of the test. The layout of strain measurement gauges is described in the following section.
Step 2: Fabrication of components
In this step, the binding of the steel bar of the beam and column is completed. The core stress area of the beam and column joint is reinforced and the reinforcement is inspected according to the final version of the construction drawings. Bolts should correspond to the holes in the steel plate joint and the beam-column joint. Concrete is mixed in the factory, transported to the laboratory, poured into the supported wetted formwork, and cured in the laboratory. Water is sprayed over the concrete three times a day for the first four days to improve the strength of the concrete for later natural curing. The formwork is removed after the component has been fully formed.
Step 3: Hoisting of specimen
Two lifting rings are welded at the diagonal position of the top of the column to facilitate the lifting of the column. Thick steel wire rope is used in the process of lifting, and wooden formwork is placed on the contact position between the concrete surface and the steel wire rope to prevent the concrete from being crushed, and then it is hoisted flat to the test bed. The joints of the beam and column are tied together for seam sticking, and grouting material is poured into the gaps to make the joints airtight. The assembly is completed by connecting and hoisting the post and the beam, inserting the high-strength bolts into the connection, and installing the reinforcing nuts. In order to ensure the smooth butt-hole of high-strength bolts, there should be a good correspondence between the bolt position and the hollow position of the steel pipe on the steel plate. The correspondence between the hole on the column and the hole on the beam should not be more than 2 mm.

3.2. Layout of Strain Measurement Gauges

Strain measurement gauges are placed at key positions including the end of the column, the node area, the core area, the beam end, the ox leg, etc., to understand the variation of strain and stress of specimen under loads. The same branch of gauges with maximum electric current of 125A are adopted in this experiment. The positions of gauges are shown in Figure 5: L1-L10 is used to measure the distribution of stress of reinforced concrete beams under loads; L11-L15 is used to measure the magnitude and direction of the main strain in the core region of the joints; Z1-Z8 is used to measure the distribution of strain of column under constant axial force; N1-N6 measures the stress–strain distribution of bolts under the action of horizontal load and vertical load.

3.3. Test Loading Scheme

The pseudo static test of low-cycle repeated loading is adopted for this study. The test equipment is loaded by Beijing Foli electro-hydraulic servo loading system, with the displacement stroke of the actuator.
This experiment took the beam end, the connection between corbel and bolt and the joint core, as the research object and used the mixed loading method to apply 670 kN of axial force to the column top (see Figure 6).

3.4. Test Loading System

According to the Code of Seismic Test for Buildings (JGJ/T101-2015) [22], the load-displacement double-control method was adopted in the test. By analyzing and calculating the specimens before yield, the load control was used and graded loading was applied. Each grade was loaded 5 kN and cycled once, and the differential loading was reduced before approximating to cracking and yield load. Displacement control was used when the specimens yielded, with each grade of load cycled 3 times, and the maximum displacement value of the specimen taken as the deformation value when the specimens yielded. The multiple of the displacement was used as the grade difference to control the loading until the bearing capacity of the specimen dropped to the point that it was not suitable for further loading.

3.5. Test Results

The test loading direction stipulates that pushing down refers to positive direction (+), pulling up refers to the negative direction (−), and the loading order is positive before negative. Considering the dead weight of the beam, the tension is greater than 15 kN of thrust. At the initial stage of loading, the deformation and strain of the specimen did not change significantly, and no cracks occurred. When loaded to +30 kN, the first crack appeared at the beam end of the joint core area, and a crack of 0.1 mm wide appeared near the bearing plate of column. Under reverse loading of −45 kN, the first crack appeared before it closed, and the crack on the lower surface of the beam is symmetric with the crack on the upper surface of the beam. The mechanical properties and phenomena refer to the upper surface of the beam. When the force was loaded to +40 kN, the beam end continued to generate cracks under tension, and the crack width went on increasing near the bearing plate, with a maximum width of 1.5 mm. The surface strain of steel reinforcement in the tension area increased gradually, and the strain and residual deformation of the steel plate and bolt also increased. When the reverse loading was −55 kN, the corresponding cracks on the beam surface closed, but the cracks near the joint core area and bolts did not close completely. When the force was loaded to +75 kN, the beam produced large displacement and deformation, the width of the crack at the intersection of the T-shaped section of beam end and the column continued to increase to 1.8 mm, and the stress of the reinforced rebar on the beam increased suddenly to its limit. At this time, force loading was changed into displacement loading. Three levels of displacement loading of ±95 mm, ±115 mm, and ±135 mm are carried out and each level cycles three times respectively. With the load increasing, the number and width of cracks increases, and thus gradually forming through cracks as shown in Figure 7.
The final peak load is +82 kN, the peak displacement is +78 mm, the ultimate load is +72 kN (greater than 85% of the peak), and the corresponding ultimate displacement is +134 mm. During the test, there was no crack in the precast concrete column. After the precast concrete beam yields, the value of stress at connected high-strength bolts does not reach the yield strength.

4. Analysis and Comparison of Test Results

4.1. Joint Yield and Failure Load

The ultimate displacement and the ultimate bending moment are determined by the geometric drawing method. After comparison in Table 3, the ultimate bending moment of the test differed greatly from the theoretical value, mainly because the concrete grade of the T-shaped end of the beam is C40, while the concrete grade of the column is C80. Due to the punching failure in the core area at the t-shaped end of the precast concrete beam, the ultimate bending moment at the beam end is much lower than the theoretical bending moment value. Therefore, although the high-strength bolt produces a large stress, it is not the expected high-strength bolt that produces a large deformation, resulting in a large angular deformation of beam–column joints.

4.2. Hysteretic Curve

Finite element simulation of the mechanical properties of new dry-type connection joint were conducted using ANSYS software. Integral modeling is adopted in this study. Reinforcement units were regarded as subunits permeated in the concrete, of which mechanical properties can be superimposed on the plain concrete. The solid 65 units with kinematic hardening in the built-in material database of ANSYS software was selected as constitutive model. Parameters are set as follows: the elastic modulus was set to be 34 GPa; the poisson ratio was set to be 0.2; the transfer coefficient of crack opening and crack closure were set to be 0.35 and 1; meanwhile, the concrete compressive strength of beams and columns were set to be 32 MPa and 54 MPa, respectively. The common 3-D 4-joint unit solid 182 was chosen for high-strength bolts. The main model property was two-linear mixed-hardening. The elastic modulus was set to be 200 GPa; the poisson ratio was set to be 0.45; the yield strength was set to be 618 MPa and the strain-hardening modulus was set to be 20,000. In-plane constraints and normal constraints were set on the top and at the bottom of the concrete column. End face of concrete beam was set as loading end. The partition type of the model is free partition, and the mesh size of screw, concrete beam, and column was 25 mm and 100 mm, respectively. ADD action was applied to nuts and screws in order to make them work together.
The hysteretic curve of finite element simulation and experiments are compared (in Figure 8).
The hysteretic loop is full in the simulated state, which is different from the experimental results to some extent, because the numerical model material is relatively ideal, and the failure of the component caused by the uneven mechanical properties of the material is not considered in the loading process. In the actual test process, at the initial stage of loading, the force and displacement show a linear relationship. With increasing force, the area of the hysteresis ring also increases gradually, and the core area of the joint of the member is severely deformed by extrusion and has obvious shear failure. There is a certain gap with finite element simulation analysis, but the hysteretic loop obtained by the test is arched, indicating that the plastic deformation capacity of the whole component is still stronger, and under low-cycle repeated loading the joint is better at absorbing seismic energy.

4.3. Skeleton Curve

The skeleton curves in the experimental state and the simulated state were compared (see Figure 9).
The skeleton curve in the experimental state is relatively consistent with the skeleton curve in the simulated state. Both of them went through the stages of spring-yield-intensify-destroy. The comparison between the model and the test shows that the new type of assembled joint can ensure good seismic performance under the condition of a strongly bolted connection.

5. Analysis of New Dry-Type Connection Joint and Other Connection Joints

5.1. New Dry-Type Connection Joint and Pin Connection Joint

Pin connection joint is a common kind of beam–column joint used in prefabricated buildings. It usually consists of one or more steel pins embedded in the column and inserted in the beam hole, and then the gap is plastered with mortar. Tao [23] conducted a numerical simulation and experimental research on the pin connection joint (in Figure 10). When the pinned joint is thick enough to be out of the protective layer of concrete, its shear resistance and ductility are improved. And the inclination of the pin connected joint increases from 0º~60º, while the bearing capacity of the joint will also increase. The pin connection joint method provides a simple concrete beam–column dry-type connection, which is a more convenient joint to disassemble.
The pin connection is not practical in high-rise buildings because the bending moment increases with the increase of building height, which increases the instability of the connection joint. It is also not economically feasible because the connection method makes the overall structure additionally complex due to its compound nature. Moreover, the use of pin connection also leads to the development of large bending moments in joints. The new dry-type connection joint proposed in this research is more convenient to install and disassemble. Joints connected by high-strength bolts have better rotation ability and are not limited to connections for low-rise buildings. The integrated ductility and energy consumption capacity of the new joint is also better.

5.2. New Dry-Type Connection Joint and Welded Connection Joint

Welded plate connection joints are often applied to connect precast concrete members. Ersoy [24] carried out an experimental research of reversed cyclic loading on a structural framework beam-column joint connected by welding (see Figure 11). The result shows that the strength, stiffness, and energy consumption of joints connected by welding are equivalent to those of cast-in-situ joints, but it is difficult to control the installation quality of the joint connected by welding during on-site construction. Since there is no obvious plastic hinge area during failure in this connection mode, brittle failure is likely to occur at the welding seam under the action of repeated earthquake loads, so its energy consumption performance is poor.
Compared with welded connection joints, the new dry-type connection joint in this research has been shown to be more conveniently installed on site, and the hysteretic curve and skeleton curve reflect that the new joint has better ultimate rotation capacity and deformation capacity as well as better energy consumption under earthquake conditions.

5.3. New Dry-Type Connection Joint and Ribbed Angle Iron Connection Joint

Vidjeapriya [25] designed prefabricated concrete beam–column joint connection integrating bolt corbel and ribbed angle iron (Figure 12). The low-cycle repeated test on a 1/3 scale model was carried out, in which the angle iron was connected to the prefabricated concrete beam–column through bolts. In the process of repeated loading, the failure mode and crack morphology of the ribbed angle iron connection are consistent with a strong column and weak beam. In practical applications, the biggest problem in the failure of assembled beam–column joints, is the joint itself. The experiments have shown that the new connection joint can better address the problem. The common advantage of the new joint and ribbed angle iron is their good energy consumption capability. However, for ribbed angle iron connected joints, the two-way ribbed stiffener causes joints to have a reduced bearing capacity and be additional vulnerable to damage, thus negatively affecting floor connections in actual projects.
The new dry-type connection joints with semi-rigid structure can better resist horizontal action. In addition, the result of the experiment shows that they have better bearing capacity.

6. Conclusions and Future Research

6.1. Conclusions

In this study, a range of pseudo static tests of beam–column connection joints were carried out. From the test results, the mechanical properties and performance were evaluated and compared. The following conclusions can be drawn.
(1) The new beam–column joint connected by high-strength bolts has high rotation rigidity, but still has good rotational capability and a reasonable amount of ductility.
(2) Due to the high strength of the connection bolts and the fact that the concrete beam–column intersection is easily extruded under increased loading, the concrete beam end is liable to be destroyed first by punching before the bolts fail. Therefore, when designing the beam end, it is necessary to pay attention to avoid the reduction of capacity due to the punching failure of beam end.
(3) With high bolt connection strength, the new assembled joint can ensure that under the action of low cyclic repeated load, the whole assembled structural system maintains a full hysteretic curve, can better absorb seismic energy, and is structurally earthquake resistant.
(4) By comparing some dry-type connection joints, the new assembled joint connected by high-strength bolts in this test are more convenient to install and disassemble, have better bearing capacity, ductility and energy consumption capability, and are more suitable for an actual seismic event.
The results provide a foundation for the analysis of assembled structural framework systems based on different forms of dry-type connection joints.

6.2. Future Research

(1) It is found that the connection quality of the high strength bolt has a great influence on the performance of the new dry-type connection joint. The tests reveal that in actual operation the connection between the bolt on the beam and the bolt on the column is not sufficiently complete. From this experimental experience, more attention should be paid to dimensional accuracy when designing and constructing components.
(2) It is found from the tests that the connection bolts are very strong so that the concrete beam is destroyed before the bolt connection fails. To help resolve this imbalance, future research could reduce the strength grade of the high-strength bolts, or the beam end in contact with the column could be equipped with more anti-punching shear rebar.

Author Contributions

Conceptualization, W.M., K.D., J.H., V.W.Y.T.; Methodology, W.M., Y.L., K.D., B.C., J.H., Lab preparation and tests, W.M., Y.L., K.D., Writing the original manuscript: W.M., Y.L., K.D., B.C., J.H., V.W.Y.T.; Reviewing and editing: W.M., B.C., J.H., V.W.Y.T.; Supervision: W.M., K.D.

Funding

This research was funded by the National Key Research & Development Program of China, grant number 2016YFC0701500.

Acknowledgments

The research project has been funded by the National Key Research & Development Program of China (2016YFC0701500). The authors would like to thank the laboratory provided by Anhui Jianzhu University and the lab technicians for their help with the testing work.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Boafo, F.; Kim, J.H.; Kim, J.T. Performance of Modular Prefabricated Architecture: Case Study-Based Review and Future Pathways. Sustainability 2016, 8, 558. [Google Scholar] [CrossRef]
  2. Jiang, R.; Wu, C.; Mao, C.; Shrestha, A. Ecosystem Visualization and Analysis of Chinese Prefabricated Housing Industry. Procedia Eng. 2016, 145, 436–443. [Google Scholar] [CrossRef] [Green Version]
  3. Zuo, J.; Zhao, Z.Y. Green building research–current status and future agenda: A review. Renew. Sustain. Energy Rev. 2014, 30, 271–281. [Google Scholar] [CrossRef]
  4. Yoo, M.; Kim, J.; Choi, C. Effects of BIM-Based Construction of Prefabricated Steel Framework from the Perspective of SMEs. Appl. Sci. 2019, 9, 1732. [Google Scholar] [CrossRef]
  5. Xu, W.; Yang, X.; Wang, F.; Chi, B. Experimental and numerical study on the seismic performance of prefabricated reinforced masonry shear walls. Appl. Sci. 2018, 8, 1856. [Google Scholar] [CrossRef]
  6. Tam, V.W.; Hao, J.L. Prefabrication as a mean of minimizing construction waste on site. Int. J. Constr. Manag. 2014, 14, 113–121. [Google Scholar] [CrossRef]
  7. Huang, Y.X.; Zhu, L.; Ye, Z.X. The research overview of the connection method of prefabricated concrete structure. Concrete 2013, 261, 120–126. [Google Scholar]
  8. Liu, T.Z.; Yan, S.H.; Wang, W. Research situation and outlook of assembled concrete structure. Shanxi Archit. 2016, 42, 55–57. [Google Scholar]
  9. Wu, D. Research overview of the connection method of assembled building joints. Chin. Overseas Archit. 2016, 67, 150–151. [Google Scholar]
  10. Wang, Y.C.; Li, J.F.; Jiang, S.l. Research of key connection technology in the design of assembled concrete structure design. Archit. Struct. 2016, 46, 91–94. [Google Scholar]
  11. Huang, X.H. Research on New Prefabricated Concrete Frame Joints; Southeast University: Nanjing, China, 2006. [Google Scholar]
  12. Yan, X.; Wang, S.; Huang, C.; Qi, A.; Hong, C. Experimental study of a new precast prestressed concrete joint. Appl. Sci. 2018, 8, 1871. [Google Scholar] [CrossRef]
  13. Hassane, O.; Yuji, I.; Hideki, K.; Tetsu, K.; Nobuyuki, Y.; Keijiro, O. Seismic Performance and Flexural Stiffness Variation of Assembled Precast Concrete Beam Jointed At Mid-span Using Transverse Bolts. J. Adv. Concr. Technol. 2009, 7, 205–216. [Google Scholar]
  14. Cheng, W.P.; Song, Y.P.; Wang, J. Experimental study on the seismic performance of prefabricated partial steel-reinforced concrete frame beam-column joints. J. Dalian Univ. Technol. 2015, 55, 171–178. [Google Scholar]
  15. Choi, H.K.; Choi, Y.C.; Choi, C.S. Development and testing of precast concrete beam-to-column connections. Eng. Struct. 2013, 56, 1820–1835. [Google Scholar] [CrossRef]
  16. Nzabonimpa, J.D.; Hong, W.K.; Park, S.C. Experimental investigation of dry mechanical beam-column joints for precast concrete based frames. Struct. Des. Tall Spec. Build. 2016, 26, e1337. [Google Scholar] [CrossRef]
  17. Pan, P.; Wang, H.S.; Guo, H.S. Experimental study on the seismic behavior of post-tensioned unbonded prestressing dry-type connected beam-column joints. J. Build. Struct. 2018, 39, 46–55. [Google Scholar]
  18. Cheng, D.H.; Tian, Y.H.; Zhang, L.Q.; Xu, P.C. Experimental study on static behavior of dry joint connected assembled concrete beam. J. Archit. Sci. Eng. 2017, 34, 31–38. [Google Scholar]
  19. Zhang, L.B.; Zhou, Z.H. Analysis of the shearing performance of a new assembled frame dry-type connection joints with dark corbel in core area. Shanxi Archit. 2018, 44, 33–35. [Google Scholar]
  20. Chen, W.; Xiong, F. Experimental study on seismic performance of dry-type connected assembled wall structure. J. Build. Struct. 2018, 39, 54–64. [Google Scholar]
  21. Liu, X.C.; Zhan, X.X.; Pu, S.H. Seismic performance study on slipping bolted truss-to-column connections in modularized prefabricated steel structures. Eng. Struct. 2018, 163, 241–254. [Google Scholar] [CrossRef]
  22. Code of Seismic Test for Buildings: JGJ/T101-2015; China Architecture & Building Press: Beijing, China, 2015.
  23. Tao, D.; Xiao, J.Z.; Zhang, Q.T.; Akbarnezhad, A. Experimental and numerical studies on design for deconstruction concrete connections: An overview. Adv. Struct. Eng. 2018, 21, 2198–2214. [Google Scholar]
  24. Ersoy, U.; Tankut, T. Precast concrete members with welded plate connections under reversed cyclic loading. PCI J. 1993, 38, 94–100. [Google Scholar] [CrossRef]
  25. Vidjeapriya, R.; Jaya, K.P. Experimental study on two simple mechanical precast beam-column connections under reverse cyclic loading. J. Perform. Constr. Facil. 2013, 27, 402–414. [Google Scholar] [CrossRef]
Figure 1. Frame structure plan.
Figure 1. Frame structure plan.
Sustainability 11 03348 g001
Figure 2. A three-dimensional joint diagram with corbel.
Figure 2. A three-dimensional joint diagram with corbel.
Sustainability 11 03348 g002
Figure 3. Elevation of beam and column test specimen.
Figure 3. Elevation of beam and column test specimen.
Sustainability 11 03348 g003
Figure 4. Process of specimen making.
Figure 4. Process of specimen making.
Sustainability 11 03348 g004
Figure 5. Layout of strain gauges.
Figure 5. Layout of strain gauges.
Sustainability 11 03348 g005
Figure 6. Loading diagram.
Figure 6. Loading diagram.
Sustainability 11 03348 g006
Figure 7. Crack diagram of specimen.
Figure 7. Crack diagram of specimen.
Sustainability 11 03348 g007aSustainability 11 03348 g007b
Figure 8. Displacement curve.
Figure 8. Displacement curve.
Sustainability 11 03348 g008
Figure 9. Load displacement curve.
Figure 9. Load displacement curve.
Sustainability 11 03348 g009
Figure 10. Pin connected assembled frame beam–column joint [20].
Figure 10. Pin connected assembled frame beam–column joint [20].
Sustainability 11 03348 g010
Figure 11. Assembled frame beam–column joint connected by welding.
Figure 11. Assembled frame beam–column joint connected by welding.
Sustainability 11 03348 g011
Figure 12. Bolt corbel-ribbed angle iron connection joint.
Figure 12. Bolt corbel-ribbed angle iron connection joint.
Sustainability 11 03348 g012
Table 1. Concrete performance index (unit: N/mm2).
Table 1. Concrete performance index (unit: N/mm2).
Concrete Strength3 Days7 Days28 Days
C4027.2839.2851.20
C4026.6838.6846.32
C4026.1338.1348.15
C8027.3077.3084.36
C8028.2078.2287.12
C8027.9077.9185.46
Table 2. Rebar and bolt performance index (unit: N/mm2).
Table 2. Rebar and bolt performance index (unit: N/mm2).
TypeRebar/Bolt Diameter d (mm)Yield Strength fykUltimate Strength fstkElongation δ
HPB3008327.6447.126.3%
HPB30010344.9468.324.6%
HRB40012465.2577.321.6%
HRB40014447.4567.623.2%
HRB40016437.6620.423.2%
HRB40018456.4589.622.6%
HRB40022421.3571.919.6%
HRB40025456.6605.720.2%
Grade8.830618.7785.211.4%
Table 3. Capacity and displacement value.
Table 3. Capacity and displacement value.
SpecimenTheoretical Bending Moment M y ( k N . m ) Ultimate Bending Moment M max ( k N . m ) Ultimate Displacement Δ max ( m m ) Failure Mode
Beam456266134The concrete of T-shaped section where the beam end intersects the column is partially destroyed by punching first, and then the bending moment is destroyed

Share and Cite

MDPI and ACS Style

Ma, W.; Li, Y.; Ding, K.; Cheng, B.; Liu, J.; Hao, J.; Tam, V.W.Y. Mechanical Properties of New Dry-Type Beam-Column Bolt Connection Joint. Sustainability 2019, 11, 3348. https://doi.org/10.3390/su11123348

AMA Style

Ma W, Li Y, Ding K, Cheng B, Liu J, Hao J, Tam VWY. Mechanical Properties of New Dry-Type Beam-Column Bolt Connection Joint. Sustainability. 2019; 11(12):3348. https://doi.org/10.3390/su11123348

Chicago/Turabian Style

Ma, Wei, Yue Li, Kewei Ding, Baoquan Cheng, Jianhua Liu, Jianli Hao, and Vivian Wing Yan Tam. 2019. "Mechanical Properties of New Dry-Type Beam-Column Bolt Connection Joint" Sustainability 11, no. 12: 3348. https://doi.org/10.3390/su11123348

APA Style

Ma, W., Li, Y., Ding, K., Cheng, B., Liu, J., Hao, J., & Tam, V. W. Y. (2019). Mechanical Properties of New Dry-Type Beam-Column Bolt Connection Joint. Sustainability, 11(12), 3348. https://doi.org/10.3390/su11123348

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop