Characterization and Analysis of Acetaldehyde Wastewater by Molecular Weight Distribution, Hydrophilicity, and Chemical Composition

1
State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research Academy of Environment Sciences, Beijing 100012, China
2
College of Chemical and Environmental Engineering, China University of Mining & Technology-Beijing, Beijing 100083, China
3
Research Center of Environmental Pollution Control Engineering Technology, Chinese Research Academy of Environmental Sciences, Beijing 100012, China
*
Authors to whom correspondence should be addressed.
Sustainability 2022, 14(11), 6540; https://doi.org/10.3390/su14116540
Submission received: 12 April 2022 / Revised: 18 May 2022 / Accepted: 19 May 2022 / Published: 27 May 2022

Abstract

:
Acetaldehyde is a typical toxic substance of the petrochemical industry. Dissolved organic carbon (DOC) plays an important role in wastewater treatment. Therefore, the molecular weight, hydrophilicity, and chemical composition of DOC in acetaldehyde wastewater were evaluated. First, the molecular weight (MW) distribution was investigated; the results showed that acetaldehyde wastewater was mainly composed of components with a MW less than 1 kDa, and possessed higher proportion of protein-like substances that were dominant contributors to membrane fouling. Then, the distribution of hydrophobicity was evaluated; hydrophobic bases were reported to be slowly biodegradable fractions due to the high humic content. Finally, gas chromatography–mass spectrometry (GC-MS) was utilized to determine chemical composition, and 30 pollutants were detected. Aldehydes, hydrocarbons, ketones, alcohols, furans, phenols, and organic acids were the dominant pollutants. Most of them were moderately toxic compounds. The comprehensive characterization of acetaldehyde wastewater will contribute to control strategies and sustainable development.

1. Introduction

Acetaldehyde is an important fine and specialty chemical intermediate, mainly used in the production of acetic acid and the synthesis of pyridine, pentaerythritol, and n-butanol [1,2]. Due to its broad range of applications in manufacturing and human life, wastewater from manufacturing processes is increasing every year. When acetaldehyde wastewater is directly discharged into biological treatment systems, it poses a threat to microorganisms. The receiving water can be polluted by acetaldehyde wastewater, the environment and humans will be severely affected [3,4,5]. Because acetaldehyde wastewater possesses complex water quality and toxicity to microorganisms, studies focusing on acetaldehyde wastewater have become increasingly more popular.
Current studies have placed more emphasis on the removal of pollutants in aldehyde wastewater. Physical or chemical methods and biochemical methods were applied to aldehyde wastewater treatments. For example, Wu [6] used a 5% ZSM-5-PDMS/Nylon membrane to deal with aldehyde mass concentration of 8%; the separation factor of acetaldehyde/water achieved was 35 and the permeation flux was 233.3 g·m−2·h1. Although pervaporation exhibited superior advantages in simplicity and recovery efficiency, it was deficient in the economy. Biological methods are thought to be a more attractive strategy. Tian [7] proposed that hydrolytic acidification presented enormous potentiality in treating high-strength aldehyde wastewater for hydrolytic and acidifying bacteria showed superior performance in withstanding acetaldehyde. Tian [8] employed zero-valent iron-coupled hydrolytic acidification to pretreat chloroacetaldehyde wastewater, and the dechlorination ratio was found to increase by 20.23%. Many factors can influence removal effects, such as operation parameters, influent quantity, and the characteristics of typical pollutants. Among them, influent quality and pollutants characteristics are of vital significance to treatment process selection and operation. For example, Song investigated the performance of the micro aeration hydrolytic acidification process degrading wastewater from the manufacture of 2-butenal and the fluorescence characteristics of EPS. Moreover, the main refractory and toxic substances were determined with gas chromatography–mass spectrometry (GC-MS). They concluded that the micro aeration hydrolytic acidification process could be employed for the pretreatment of 2-butenal manufacture wastewater [9]. As it contains many types of high-strength organic matter, acetaldehyde wastewater has complicated character and varies over time. Until now, no comprehensive characterization of dissolved organic matter (DOM) has been performed on acetaldehyde wastewater. Therefore, the characterization and analysis of acetaldehyde wastewater are urgently required.
The distribution of molecular weight (MW) and hydrophobicity are the basic properties and essentially representative indicators in wastewater quality analysis [10,11]; the distribution of hydrophobicity and MW were reported to be closely related to biodegradability and membrane fouling potential, etc. [12,13,14]. For example, Fan applied polyvinylidene fluoride (PVDF) membranes to samples isolated from surface waters to explore interactions between fouling potential and hydrophilic matter. The results showed that the order of membrane fouling potential was hydrophilic neutral (HIN) > hydrophobic acid (HOA) > hydrophilic matter (HIM) [15]. Park investigated spectroscopic and chromatographic changes in dissolved organic matter of influent and treated sewage for a wastewater biological treatment plant. The conclusion was that fractions with lower MW could be easily degraded, and that higher MW fractions were more biologically recalcitrant [16]. Samples with the various distributions of MW and hydrophobicity exhibited different optical signals. The interaction among MW, hydrophobicity and optical signals was helpful for the in-depth analysis of wastewater. For instance, ultraviolet (UV) and specific ultraviolet absorbance (SUVA) were instructive measurements for aromaticity [17]. The UV and SUVA can also be indicators of MW as higher MW fractions containing aromatics possessed higher MW. Andrew [18] found that A2O and A/O treatment process elevated wastewater aromaticity, and simultaneously increased the MW of dissolved organic matter (DOM) in municipal wastewater. The trend was in agreement with MBR; fractions with a higher MW had a higher SUVA than fractions with a lower MW [19]. However, textile dyeing wastewater followed the opposite pattern [20]. The differences may be attributed to the wastewater source. There is also a correlation between fluorescence properties and hydrophobicity. For example, hydrophobic fractions (HOS) were found to possess aromatic structure by three-dimensional excitation and emission matrix (3D EEM) fluorescence spectroscopy [21]. More humics were found in HOA and hydrophobic neutral (HON), and aromatic proteins were found in hydrophobic bases (HOB) more frequently [22,23]. The characterization of aromaticity and fluorescence properties cannot satisfy the requirement for wastewater quality analysis. More analysis techniques, such as GC-MS, have been applied for precise quantitative analysis [24,25].
The main objective of this study was to supply the research and treatment of acetaldehyde wastewater with an in-depth characterization. First, resin grading and multistage ultrafiltration were used to separate acetaldehyde wastewater into corresponding fractions, then the fractions were characterized using UV–Vis and 3D EEM spectroscopy to investigate the composition features. Further, GC-MS was utilized to qualitatively determine the dominant organic contaminant in acetaldehyde wastewater. The results of this study will provide some fundamental information about which classes of DOM in acetaldehyde wastewater should be removed to ensure the smooth operation of impending treatments.

2. Materials and Methods

2.1. Wastewater Collection and Storage

The water samples were taken from the drainage of an acetaldehyde production unit of a petrochemical enterprise in northeast China. The basic indicators were measured immediately after sampling. The remaining samples were stored at 4 °C in a refrigerator to ensure the accuracy of subsequent analyses.

2.2. Conventional Characterizations

The water sample was acidic (pH ≈ 3.3) with COD of 3886.5 mg/L, BOD of 1943.1 mg/L, and DOC of 1305.6 mg/L. It shall be biodegradable due to the high B/C ratio (0.5).
All samples were filtered through 0.45 mm cellulose acetate membrane before analysis. A DRB200 COD digester (HACH, Loveland, CO, USA) and BOD Trak™ II BOD analyzer (HACH, Loveland, CO, USA) were used for COD detection and BOD5 detection, respectively. The referenced analytical method was the Hach Company test program. pH was determined with a pH meter (METTLER TOLEDO FE20). DOC was determined by a TOC analyzer (TOC-VCPH, Shimazu, Japan).

2.3. Organic Carbon Analysis

The UV absorption spectra of samples were measured using a UV-1700 spectrophotometer (SHIMADZU, Kyoto, Japan) coupled with a 1 cm path length quartz cuvette. Analysis conditions were as follows: the scanning wavelength ranged from 190 nm to 400 nm; the scanning speed is medium automatic scanning; slit width was 5.0 nm; and sampling interval was 0.2 nm.

2.4. 3D EEM Fluorescence Spectroscopy Analysis

Before the 3D EEM fluorescence spectroscopy (F-7000 FL, Hitachi, Tokyo, Japan) test, samples were diluted for measurement. The operation was conducted under 3D scanning mode at a scanning speed of 12,000 nm/min, the sampling interval was 5 nm, and excitation (EX) and emission (EM) scan areas were 200–450 nm and 200–550 nm, respectively.

2.5. Ultrafiltration Membrane Filtration

The samples were adjusted to neutral and prefiltered to ensure smooth progress of the subsequent ultrafiltration. The filtrate was then added to a built-in magnetic stirring agitated ultrafiltration cup with a volume of 400 mL. The ultrafiltration (UF) was then completed using high purity N2 (99.999%) of less than 0.1 MPa as the driving force. The samples were filtered through an intercept with MW of 100 kDa, 30 kDa, 10 kDa, 5 kDa, and 3 kDa ultrafiltration membrane in parallel. Finally, filtrate at five MW levels was collected for analysis and testing.

2.6. Resin Fractionation

Nonionic Amberlite XAD-8 resins were used to isolate DOM into HIM, HOA, hydrophobic bases HOB and HON. The resins were soaked in 40 mL ultrapure water to remove visible impurities, and then were cleaned with 40 mL ethanol for 24 h and then rinsed with ultrapure water. Then, 20 mL (wet volume) cleaned XAD-8 resin was packed into a glass column and rinsed with 40 mL 0.1 mol/L NaOH, 0.1 mol/L HCl, and ultrapure water until the DOC of the effluent was less than 2 mg/L.
Fractionation was conducted concerning the method established by Leenhee [26]. One liter of neutral prefiltered sample was pumped through the XAD-8 resin column at a rate of 10 mL/min. The effluent was defined as fraction-1. The HOB was backwash eluted with 200 mL of 0.1 mol/L HCl followed by 100 mL of ultrapure water. Fraction-1 was adjusted to pH 2 with HCl and recycled through the XAD-8 column at the rate of 10 mL/min. The portion that passed through the resin column was denoted the HIM. HOA was desorbed by backflush elution with 200 mL of 0.1 mol/L NaOH followed by 100 mL of ultrapure water. Then HON fraction was obtained by XAD-8 resin elution with methanol. After fractionation, each fraction volume was adjusted to one liter.

2.7. Liquid–Liquid Extraction/GC-MS (LLE-GC-MS)

Before GC-MS determination, 10 mL dichloromethane (HPLC-grade) was used to extract a sample of 100 mL three times under acidic (pH ≈ 2) and alkaline (pH ≈ 12) conditions for 2 min, respectively. The six extracted phases were mixed and anhydrous sodium sulfate was used to dehydrate the mixture. Then, the mixture was dried under nitrogen atmosphere at 25 °C. Dichloromethane (1.0 mL) was applied to dissolve the residue, and 1 μL of mixture was injected into 7890/5975 GC-MS system (Agilent, Santa Clara, CA, USA) coupled with an HP-5MS capillary column (60 m × 0.25 mm i.d.). The injector temperature was maintained at 260 °C. The temperature program was operated at 40 °C for 2 min, raised at 8 °C/min to 300 °C, and kept at 300 °C for 3 min. The solvent delay time was 20 s. Agilent MSD Chemstation E.02.00.493 software was used to operate the system.

2.8. Purge and Trap-GC/MS

A sample of 5 mL was injected into a purge and capture sampler, and the purge gas flow rate was set at 40 mL/min. The purge time was 11 min; purge temperature was room temperature; dry purge lasted for 1 min; pre-desorption temperature was 180 °C; flow rate was 300 mL/min. The baking was conducted at 220 °C with a flow rate of 400 mL/min, and the process lasted for 10 min. The sample was injected by purge and capture procedure. The sample was separated by chromatography and then detected by mass spectrometry.

3. Results and Discussions

3.1. The MW Size Distribution of Acetaldehyde Wastewater

3.1.1. DOC Distributions Based on MW

The DOC distribution of each fraction is shown in Figure 1. In general, the DOC content of fractions increased as MW decreased. In particular, fractions with MW below 1 kDa reached 1075.2 ± 25.6 mg/L, accounting for 82% of the total dissolved organic carbon. The organic content of components with molecular weight ranging from 1 kDa to 3 kDa and 30 kDa to 100 kDa was slightly lower than that of the previously mentioned MW ranges; their DOC was 97.8 ± 9.8 mg/L and 58.2 ± 2.7 mg/L, accounting for 8 and 4% of the total dissolved organic carbon, respectively. The remaining molecular weight ranges (3~5 kDa, 5~10 kDa, 10~30 kDa, and >100 kDa) contained less organics, with DOC of 27.9 ± 2.4 mg/L, 11.4 ± 1.1 mg/L, 8.4 ± 0.9 mg/L, and 26.7 ± 3.3 mg/L, respectively. Organic matter with molecular weight above 100 kDa only accounted for 2% of the total organic carbon content. Particle size distribution of DOM significantly depends on the type of wastewater [27]. Most dissolved organics possess lower MW in acetaldehyde wastewater, which was in agreement with industrial wastewater and municipal wastewater MW distribution [28]. Compared with higher MW fractions, the low MW fractions are more biodegradable [26]. Thus, it can be inferred that acetaldehyde wastewater is easily biodegradable, which is consistent with the relatively high B/C of acetaldehyde wastewater.
In conclusion, the selection of acetaldehyde wastewater treatment should focus on the removal of small molecular organic matter; it is recommended to apply biological methods to treat acetaldehyde wastewater.

3.1.2. UV Distributions Based on MW

The UV distributions are shown in Figure 2, there were similar trends in the UV absorption spectrum between different molecular weight intervals, indicating that the conjugate characteristics of organic compounds in different molecular weight intervals were almost the same. The strong absorption peak at 220~290 nm was attributed to carbon–carbon double bonds and benzene rings. The absorbance value wavelengths greater than 300 nm gradually decreased and tended to zero, indicating that the wastewater did not contain organic compounds with polybenzene rings. The SUVA254 of components showed a narrow distribution that varied from 0.14 to 0.16 L·mg−1·m−1. According to Edzwald’s [17] theory, when the SUVA254 is less than 3 L·mg−1·m−1, it means that the dissolved organic matter in wastewater has relatively lower MW and a high degree of biochemical properties. This conclusion was consistent with the biodegradability and MW distributions of samples.
In summary, the focus of pollutant removal in acetaldehyde wastewater should be lower MW organics with carbon–carbon double bonds and benzene rings.

3.1.3. 3D Fluorescence Distributions Based on MW

The fluorescence properties of fractions with different MW were shown in Figure 3. The results showed that the shape of the spectra was roughly similar, but the location of Flu 1 was gradually red-shifted as the MW increased. Since the existence of carbonyl, hydroxyl, alkoxyl, and carboxyl constituents are responsible for the redshift [29,30]. It can be inferred that acetaldehyde wastewater contains organics with the above substituent groups possessing relatively higher MW. Fractions with MW below 1 kDa exhibited the highest overall fluorescence intensity, it was thought to be the main contributor to the fluorescence intensity of acetaldehyde wastewater.
According to the theory proposed by Chen [29], the spectrum is divided into five regions: region I (Ex/Em = 200~250 nm/280~330 nm) indicates tryptophan, tyrosine, phenylalanine and other aromatic proteins. Region II (Ex/Em = 200~250 nm/330~380 nm) indicates an aromatic protein. Region III (Ex/Em = 200~250 nm/380~550 nm) indicates a fulvic acid-like substance. Region IV (Ex/Em = 250~280 nm/280~380 nm) indicates a solubility-like microbial metabolite. Region V (Ex/Em = >250 nm/380~550 nm) indicates humic acid like substance. Two predominant peaks were identified in all the EEM spectra (Flu1 Ex/Em near 240/375 nm; Flu 2, Ex/Em near 320/400 nm). Flu1 and Flu 2 were assigned to aromatic protein-like (Ⅰ) and humic acid-like substances, respectively. Flu 3 was a unique peak of fractions with MW less than 1 kDa, located at Ex/Em near 280/360 nm. It was thought to be related to solubility-like microbial metabolite. For further exploration of fluorescence properties, fluorescence regional integration (FRI) was employed for quantititave analysis of the fractions.
To perform FRI analysis, the first step is to normalize the integrated volume of the EEM spectrum to the relative area, and then the normalized percent fluorescence response (P) is calculated as a ratio of normalized volumes in each region to the total volumes. The profiles of FRI in each fraction are shown in Figure 4. Pp is defined as the sum of protein-like regions (Regions I, II, and IV) and Ph is defined as the sum of humic- and fulvic-like regions (Regions III and VI).
As MW increased, Pp decreased in the following order of 62.2, 51.8, 51.4, 39.6, 44.8% and 46.2%, respectively. It is generally accepted that protein-like substances are more biodegradable, but also preferentially attach to membrane surfaces, resulting in fouling [31,32,33,34]. Acetaldehyde wastewater is mainly composed of protein-likes substance with low MW, so it is recommended to apply biological methods to treat acetaldehyde wastewater; previous studies have reported employing membrane bioreactors (MBRs) for aldehydes-containing wastewater [35,36,37]. With the application of MBR technology, protein-like substances with lower MW will be removed.

3.2. The Hydrophobicity Distribution of Acetaldehyde Wastewater

3.2.1. DOC Distributions Based on Hydrophobicity

After the adsorption and separation of acetaldehyde wastewater by Xad-8 macroporous adsorption resin, samples were divided into HOA, HOB, HIM, and HON. The DOC distribution of each component was shown in Figure 5. According to Figure 5, the DOC of HIM in acetaldehyde wastewater was the highest, at 576.6 ± 31.6 mg/L, accounting for 44% of the total DOC. HOB and HOA follow HIM, accounting for 23 and 30% of total DOC, respectively. HON has the lowest soluble organic carbon content of 42.8 ± 17.7 mg/L.
In summary, the organic matter in acetaldehyde wastewater was mainly hydrophilic substances, while the hydrophobic organic matter was mainly composed of acidic and alkaline substances. The hydrophobicity distribution of DOM in acetaldehyde wastewater was similar to Wang’s [26]. An increment in HOB content may be attributed to the lower pH of acetaldehyde wastewater, which causes the generation of hydrophobic fractions [38].

3.2.2. UV254 Distributions Based on Hydrophobicity

The UV absorption spectra of each component in acetaldehyde wastewater is shown in Figure 6. It can be seen that the UV absorption spectra of HOA, HOB, and HIM varied similarly (HON’s UV absorption spectrum was ignored due to the reaction of eluent and acetaldehyde wastewater). The ultraviolet absorbance of HOB at 225 nm was higher than that of other components, indicating that most of the conjugated double bonds in the wastewater were attributed to hydrophobic alkaline substances. The spectral curve of HOA at the wavelength of 310–340 nm was higher than that of other components, indicating that benzene macromolecular organics alkaline were attributed to hydrophobic acid.
HOA and HOB contained a large amount of unsaturated structuralized aromatic compounds, and their UV254 reached 0.84 and 0.75, respectively, accounting for 45% and 40% of the total UV254. HIM and HON processed a lower content of unsaturated structured aromatic compounds, accounting for 14 and 1% of the total UV254, respectively. (UV254 of HON was determined as the difference between the measured UV254 and the sum of identified fractions.)
The spectral slope SR (the ratio of the logarithmic slope of absorption coefficients in the wavelength ranges of 275–295 nm and 350–400 nm) is often used to indicate the molecular weight change of DOM, which is inversely proportional to MW [39]. The SR of HIM, HOB, and HOA was 1.7165, 0.8238, and 0.7702, respectively. It could be inferred the order of MW ranked as HOA > HOB > HIM. The conclusion was consistent with Yan’s [40] conclusion that the lower content of hydrophilic corresponded to low MW components. Since the degradation of acetaldehyde wastewater is focused on lower MW fractions, the removal of HIM should also be taken seriously.

3.2.3. 3D Fluorescence Distributions Based on Hydrophobicity

As is shown in Figure 7, the 3D EEM spectra of three fractions and the original sample were different from each other. Three fluorescence peaks were identified in HOB (Flu 1 Ex/Em near 230/375 nm; Flu 2 Ex/Em near 330/375 nm; Flu 3 Ex/Em near 290/330 nm); Flu 1 and Flu 2 were also detected in HIM, and the fluorescence peak intensity of HOB was much higher than that of HIM. Two fluorescence peaks were identified in HOA (Flu 4 Ex/Em near 220/355 nm; Flu 5 Ex/Em near 270/315 nm). A weak fluorescence peak was detected in the raw water, which was located at Ex/Em near 320/425 nm. All the fractions contained fluorescence peaks that did not exist in the original water sample. One possible reason may be that HON or impurities introduced by the grading operation contained substances that covered fluorescence; another speculation is the interaction between the components caused fluorescence quenching.
The profiles of FRI in each fraction are shown in Figure 8; the order of humic content was HOB > HOA > HIM, with relative content of 25.5, 15.7, and 15.3%, respectively. Humic was thought to be biological recalcitrant. It can be inferred that the biological recalcitrant substance in acetaldehyde wastewater was HOB. Therefore, tertiary treatment should focus on the removal of HOB. On the contrary, HIM contains a higher content of proteinaceous substances, which may cause membrane fouling [34]. The conclusion was consistent with previous research that the hydrophilic fraction is more frequently considered as the major foulant of the membrane [41].
In conclusion, HOB shall be the focus of tertiary treatment, and HIM shall be removed to eliminate membrane fouling.

3.3. Analysis of Organic Pollutants

To ascertain the dominant organic contaminant in acetaldehyde wastewater, GC-MS was used to determine organics qualitatively. As shown in Table 1, 30 compounds in acetaldehyde wastewater could be detected by this method. The toxicity level of the compounds was obtained by searching both the chemical toxicity database and toxicity grading standard. As shown in Table 1, there was one highly toxic compound, fourteen moderately toxic compounds, six mildly toxic compounds, and nine compounds with unknown toxicity in acetaldehyde wastewater. It can be seen that acetaldehyde wastewater exhibited moderate toxicity, and could therefore not be directly discharged into the microbial treatment system.
Aldehydes, acids, alkane, alcohols, and ketones comprised about 70, 4, 6, 17, and 4% of the acetaldehyde wastewater. Both aldehydes and alcohols were low-MW organics; this might explain why the acetaldehyde wastewater is mainly composed of fractions with MW below than 1 kDa. The large amounts of 5-methyl furfural, crotonaldehyde, acetic acid, chloroacetaldehyde, and 3-furaldehyde presented in acetaldehyde wastewater verified the existence of carboxyl and carbonyl groups, which account for the redshift in the fluorescence spectra. Most organics have hydrophilic groups, such as carboxyl and hydroxyl groups. This is consistent with the conclusion that acetaldehyde wastewater was mainly composed of HIM.

4. Conclusions

To operate a wastewater treatment capable of removing undesirable pollutants from acetaldehyde wastewater in an energy-effective manner, the distribution of MW/hydrophobicity, optical characteristics, and chemical composition of acetaldehyde wastewater were analyzed. The concluding remarks and suggestions may be considered as follows:
(i)
Acetaldehyde wastewater is enriched with fractions of MW < 1kDa. It is therefore recommended to use a biological method to treat acetaldehyde wastewater, but if membrane-related technology is applied, to reuse it, protein-like substances should be removed in pretreatment.
(ii)
The treatment of acetaldehyde wastewater should focus on HIM and HOB, given their potential for membrane fouling and resistance to biodegradation of HOB.
(iii)
In acetaldehyde wastewater, 30 compounds were determined by GC-MS; 5-methyl furfural, 3-furaldehyde, chloroacetaldehyde, acetic acid, and acetaldehyde were dominant pollutants. Due to their high content and relatively strong toxicity, the process of acetaldehyde wastewater treatment should focus on their fates.
In conclusion, the comprehensive characterization of acetaldehyde wastewater will contribute to control strategies and sustainable development.

Author Contributions

Conceptualization, Y.Z. and H.X.; methodology, J.Z. and Y.Y. (Yang Yang); software, Y.Q. and L.F.; validation, Y.Y. (Yin Yu), Y.Y. (Yue Yuan) and C.W.; formal analysis, Y.Y. (Yang Yang); investigation, J.Z.; resources, J.Z.; data curation, Y.Y. (Yang Yang); writing—original draft preparation, Y.Y. (Yang Yang); writing—review and editing, Y.Y. (Yin Yu) and Y.Y. (Yue Yuan); visualization, Y.Y. (Yang Yang); supervision, H.X.; project administration, L.F. and Y.Q.; funding acquisition, Y.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Budget Surplus of Central Financial Science and Technology Plan (2021-JY-05) and the National Water Pollution Control and Treatment Science and Technology Major Project of China (No. 2017ZX07402002).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Please contact the corresponding author for access.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Shimizu, S.; Abe, N.; Iguchi, A.; Dohba, M.; Sato, H.; Hirose, K. Synthesis of pyridine bases on zeolite catalyst. Microporous Mesoporous Mater. 1998, 21, 447–451. [Google Scholar] [CrossRef]
  2. Zhou, S.; Liu, Z.; Yan, X.; Di, Q.; Liu, M.; Lu, C.; Jin, G. Optimal reaction conditions for pyridine synthesis in riser reactor. Chin. J. Chem. Eng. 2018, 26, 1499–1507. [Google Scholar] [CrossRef]
  3. Matsuda, T.; Kawanishi, M.; Yagi, T.; Matsui, S.; Takebe, H. Specific tandem GG to TT base substitutions induced by acetaldehyde are due to intra-strand crosslinks between adjacent guanine bases. Nucleic Acids Res. 1998, 26, 1769–1774. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Morris, J.B.; Kerry, T.B. Upper respiratory tract deposition of inspired acetaldehyde. Toxicol. Appl. Pharmacol. 1992, 114, 140–146. [Google Scholar] [CrossRef]
  5. Vaca, C.E.; Nilsson, J.A.; Fang, J.L.; Grafström, R.C. Formation of DNA adducts in human buccal epithelial cells exposed to acetaldehyde and methylglyoxal In Vitro. Chem.-Biol. Interact. 1998, 108, 197–208. [Google Scholar] [CrossRef]
  6. Wu, Y.; Tan, H.; Li, D.; Jin, Y. Pervaporation of Aqueous Solution of Acetaldehyde Through ZSM-5 Filled PDMS Composite Membrane. Chin. J. Chem. Eng. 2012, 20, 625–632. [Google Scholar] [CrossRef]
  7. Tian, X.; Shen, Z.; Zhou, Y.; Wang, K. Inhibition on biological acidification and microbial community by high-strength acetaldehyde. Process Saf. Environ. Prot. 2020, 143, 231–238. [Google Scholar] [CrossRef]
  8. Tian, X.; Zhou, Y.; Wang, K. Chloroacetaldehyde removal by zero valent iron enhanced hydrolytic acidification pretreatment. Sustain. Chem. Pharm. 2020, 15, 100215. [Google Scholar] [CrossRef]
  9. Song, G.; Yu, Y.; Liu, T.; Xi, H.; Zhou, Y. Performance of microaeration hydrolytic acidification process in the pretreatment of 2-butenal manufacture wastewater. J. Hazard. Mater. 2019, 369, 465–473. [Google Scholar] [CrossRef]
  10. Shi, X.; Xu, C.; Hu, H.; Tang, F.; Sun, L. Characterization of dissolved organic matter in the secondary effluent of pulp and paper mill wastewater before and after coagulation treatment. Water Sci. Technol. 2016, 74, 1346–1353. [Google Scholar] [CrossRef]
  11. Xiao, K.; Sun, J.-Y.; Shen, Y.-X.; Liang, S.; Liang, P.; Wang, X.-M.; Huang, X. Fluorescence properties of dissolved organic matter as a function of hydrophobicity and molecular weight: Case studies from two membrane bioreactors and an oxidation ditch. RSC Adv. 2016, 6, 24050–24059. [Google Scholar] [CrossRef]
  12. Karahan, O.; Dogruel, S.; Dulekgurgen, E.; Orhon, D. COD fractionation of tannery wastewaters—Particle size distribution, biodegradability and modeling. Water Res. 2008, 42, 1083–1092. [Google Scholar] [CrossRef] [PubMed]
  13. Tran, N.H.; Ngo, H.H.; Urase, T.; Gin, K.Y.-H. A critical review on characterization strategies of organic matter for wastewater and water treatment processes. Bioresour. Technol. 2015, 193, 523–533. [Google Scholar] [CrossRef] [PubMed]
  14. Wei, Z.M.; Zhang, X.; Wei, Y.Q.; Wen, X.; Shi, J.H.; Wu, J.Q.; Zhao, Y.; Xi, B.D. Fractions and biodegradability of dissolved organic matter derived from different composts. Bioresour. Technol. 2014, 161, 179–185. [Google Scholar] [CrossRef] [PubMed]
  15. Fan, L.H.; Harris, J.L.; Roddick, F.A.; Booker, N.A. Influence of the characteristics of natural organic matter on the fouling of microfiltration membranes. Water Res. 2001, 35, 4455–4463. [Google Scholar] [CrossRef]
  16. Park, M.H.; Lee, T.H.; Lee, B.M.; Hur, J.; Park, D.H. Spectroscopic and chromatographic characterization of wastewater organic matter from a biological treatment plant. Sensors 2010, 10, 254–265. [Google Scholar] [CrossRef]
  17. Edzwald, J.J.W.S. Coagulation in, drinking water treatment: Particles, organcs and coagulants. Water Sci. Technol. 1993, 27, 21–35. [Google Scholar] [CrossRef]
  18. Maizel, A.C.; Remucal, C.K. The effect of advanced secondary municipal wastewater treatment on the molecular composition of dissolved organic matter. Water Res. 2017, 122, 42–52. [Google Scholar] [CrossRef]
  19. Ma, D.; Gao, B.; Sun, S.; Wang, Y.; Yue, Q.; Li, Q. Effects of dissolved organic matter size fractions on trihalomethanes formation in MBR effluents during chlorine disinfection. Bioresour. Technol. 2013, 136, 535–541. [Google Scholar] [CrossRef]
  20. Fan, J.; Li, H.; Shuang, C.; Li, W.; Li, A. Dissolved organic matter removal using magnetic anion exchange resin treatment on biological effluent of textile dyeing wastewater. J. Environ. Sci. 2014, 26, 1567–1574. [Google Scholar] [CrossRef]
  21. Du, X.; Xu, Z.; Li, J.; Zheng, L. Characterization and removal of dissolved organic matter in a vertical flow constructed wetland. Ecol. Eng. 2014, 73, 610–615. [Google Scholar] [CrossRef]
  22. Jin, P.; Jin, X.; Bjerkelund, V.A.; Østerhus, S.W.; Wang, X.C.; Yang, L. A study on the reactivity characteristics of dissolved effluent organic matter (EfOM) from municipal wastewater treatment plant during ozonation. Water Res. 2016, 88, 643–652. [Google Scholar] [CrossRef] [PubMed]
  23. Ma, D.; Peng, B.; Zhang, Y.; Gao, B.; Wang, Y.; Yue, Q.; Li, Q. Influences of dissolved organic matter characteristics on trihalomethanes formation during chlorine disinfection of membrane bioreactor effluents. Bioresour. Technol. 2014, 165, 81–87. [Google Scholar] [CrossRef]
  24. Liu, C.; Tang, X.; Kim, J.; Korshin, G.V. Formation of aldehydes and carboxylic acids in ozonated surface water and wastewater: A clear relationship with fluorescence changes. Chemosphere 2015, 125, 182–190. [Google Scholar] [CrossRef] [PubMed]
  25. Greenwood, P.F.; Berwick, L.J.; Croué, J.P. Molecular characterisation of the dissolved organic matter of wastewater effluents by MSSV pyrolysis GC–MS and search for source markers. Chemosphere 2012, 87, 504–512. [Google Scholar] [CrossRef]
  26. Wang, M.; Chen, Y. Generation and characterization of DOM in wastewater treatment processes. Chemosphere 2018, 201, 96–109. [Google Scholar] [CrossRef]
  27. Jia, X.; Jin, D.; Li, C.; Lu, W. Characterization and analysis of petrochemical wastewater through particle size distribution, biodegradability, and chemical composition. Chin. J. Chem. Eng. 2019, 27, 444–451. [Google Scholar] [CrossRef]
  28. Ravndal, K.T.; Opsahl, E.; Bagi, A.; Kommedal, R. Wastewater characterisation by combining size fractionation, chemical composition and biodegradability. Water Res. 2018, 131, 151–160. [Google Scholar] [CrossRef] [Green Version]
  29. Chen, W.; Westerhoff, P.; Leenheer, J.A.; Booksh, K. Fluorescence Excitation−Emission Matrix Regional Integration to Quantify Spectra for Dissolved Organic Matter. Environ. Sci. Technol. 2003, 37, 5701–5710. [Google Scholar] [CrossRef]
  30. Świetlik, J.; Dąbrowska, A.; Raczyk-Stanisławiak, U.; Nawrocki, J. Reactivity of natural organic matter fractions with chlorine dioxide and ozone. Water Res. 2004, 38, 547–558. [Google Scholar] [CrossRef]
  31. Wang, L.; Li, Y.-J.; Xiong, Y.; Tan, W.-B.; Zhang, L.-Y.; Li, X.; Wang, X.-S.; Xu, J.-F.; Li, T.-T.; Wang, J.-S.J.P.O. Spectroscopic characterization of DOM and the nitrogen removal mechanism during wastewater reclamation plant. PLoS ONE 2017, 12, e0187355. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Hudson, N.; Baker, A.; Ward, D.; Reynolds, D.M.; Brunsdon, C.; Carliell-Marquet, C.; Browning, S. Can fluorescence spectrometry be used as a surrogate for the Biochemical Oxygen Demand (BOD) test in water quality assessment? An example from South West England. Sci. Total Environ. 2008, 391, 149–158. [Google Scholar] [CrossRef] [PubMed]
  33. Cohen, E.; Levy, G.J.; Borisover, M. Fluorescent components of organic matter in wastewater: Efficacy and selectivity of the water treatment. Water Res. 2014, 55, 323–334. [Google Scholar] [CrossRef] [PubMed]
  34. Yu, H.; Song, Y.; Tu, X.; Du, E.; Liu, R.; Peng, J. Assessing removal efficiency of dissolved organic matter in wastewater treatment using fluorescence excitation emission matrices with parallel factor analysis and second derivative synchronous fluorescence. Bioresour. Technol. 2013, 144, 595–601. [Google Scholar] [CrossRef]
  35. Min, K.; Ergas, S.J. Volatilization and Biodegradation of VOCs in Membrane Bioreactors (MBR). Water Air Soil Pollut. Focus 2006, 6, 83–96. [Google Scholar] [CrossRef]
  36. Bayat, M.; Mehrnia, M.R.; Hosseinzadeh, M.; Sheikh-Sofla, R. Petrochemical wastewater treatment and reuse by MBR A pilot study for ethylene oxide/ethylene glycol and olefin units. J. Ind. Eng. Chem. 2015, 25, 265–271. [Google Scholar] [CrossRef]
  37. Min, K.N. Volatile Organic Compound Control in Chemical Industry Wastewater Using a Membrane Bioreactor: Emission Reduction and Microbial Characterization; University of Massachusetts Amherst: Hampshire County, MA, USA, 2006. [Google Scholar]
  38. Liang, S.; Zhao, Y.; Liu, C.; Song, L. Effect of solution chemistry on the fouling potential of dissolved organic matter in membrane bioreactor systems. J. Membr. Sci. 2008, 310, 503–511. [Google Scholar] [CrossRef]
  39. Helms, J.R.; Stubbins, A.; Ritchie, J.D.; Minor, E.C.; Kieber, D.J.; Mopper, K. Absorption spectral slopes and slope ratios as indicators of molecular weight, source, and photobleaching of chromophoric dissolved organic matter. Limnol. Oceanogr. 2008, 53, 955–969. [Google Scholar] [CrossRef] [Green Version]
  40. Yan, H.; Nian, Y.; Zhou, Y.; Yin, Q.; Zhong, Z.; Guo, X. A detailed dissolved organic matter characterization of starch processing wastewater treated by a sedimentation and biological hybrid system. Microchem. J. 2017, 130, 295–300. [Google Scholar] [CrossRef]
  41. Xiao, K.; Shen, Y.-x.; Liang, S.; Liang, P.; Wang, X.-m.; Huang, X. A systematic analysis of fouling evolution and irreversibility behaviors of MBR supernatant hydrophilic/hydrophobic fractions during microfiltration. J. Membr. Sci. 2014, 467, 206–216. [Google Scholar] [CrossRef]
Figure 1. DOC contents of various MW fractions in acetaldehyde wastewater.
Figure 1. DOC contents of various MW fractions in acetaldehyde wastewater.
Sustainability 14 06540 g001
Figure 2. The ultraviolet absorption spectrum of different MW fractions.
Figure 2. The ultraviolet absorption spectrum of different MW fractions.
Sustainability 14 06540 g002
Figure 3. Three-dimensional fluorescence spectra of different compositions with MW of (a) 1 KDa, (b) 3 KDa, (c) 5 KDa, (d) 10 KDa, (e) 30 KDa, (f) 100 KDa.
Figure 3. Three-dimensional fluorescence spectra of different compositions with MW of (a) 1 KDa, (b) 3 KDa, (c) 5 KDa, (d) 10 KDa, (e) 30 KDa, (f) 100 KDa.
Sustainability 14 06540 g003
Figure 4. FRI distribution of the five defined regions with various MW (Region I represents tryptophan, tyrosine, phenylalanine, and other aromatic proteins. Region II represents an aromatic protein. Region III represents fulvic acid-like substances. Region IV represents solubility-like microbial metabolite. Region V represents a humic acid-like substance.).
Figure 4. FRI distribution of the five defined regions with various MW (Region I represents tryptophan, tyrosine, phenylalanine, and other aromatic proteins. Region II represents an aromatic protein. Region III represents fulvic acid-like substances. Region IV represents solubility-like microbial metabolite. Region V represents a humic acid-like substance.).
Sustainability 14 06540 g004
Figure 5. DOC contents of various hydrophilic fractions in acetaldehyde wastewater.
Figure 5. DOC contents of various hydrophilic fractions in acetaldehyde wastewater.
Sustainability 14 06540 g005
Figure 6. The ultraviolet absorption spectrum of the various hydrophilic fractions.
Figure 6. The ultraviolet absorption spectrum of the various hydrophilic fractions.
Sustainability 14 06540 g006
Figure 7. Three-dimensional fluorescence spectra of (a) origin sample, (b) HOA, (c) HOB, (d) HIM.
Figure 7. Three-dimensional fluorescence spectra of (a) origin sample, (b) HOA, (c) HOB, (d) HIM.
Sustainability 14 06540 g007
Figure 8. FRI distribution of the five defined regions with various hydrophobicities. Region I represents tryptophan, tyrosine, phenylalanine, and other aromatic proteins. Region II represents aromatic protein. Region III represents fulvic acid-like substance. Region IV represents solubility-like microbial metabolite. Region V represents humic acid-like substance.
Figure 8. FRI distribution of the five defined regions with various hydrophobicities. Region I represents tryptophan, tyrosine, phenylalanine, and other aromatic proteins. Region II represents aromatic protein. Region III represents fulvic acid-like substance. Region IV represents solubility-like microbial metabolite. Region V represents humic acid-like substance.
Sustainability 14 06540 g008
Table 1. LLE-GC-MS qualitative results of acetaldehyde wastewater.
Table 1. LLE-GC-MS qualitative results of acetaldehyde wastewater.
NO.Rt (min)NamePossibility
%
Molecular WeightCASStructural FormulaPercentage %Toxicity Grade aMethods
15.785Chloroacetald-ehyde9677.987000107-20-0 Sustainability 14 06540 i0014.913LLE-GC-MS
26.177Acetic acid8660.021000064-19-7 Sustainability 14 06540 i0023.563LLE-GC-MS
36.504Trichloromethane91117.914000067-66-3 Sustainability 14 06540 i0030.2352LLE-GC-MS
46.782Dichloroacetaldehyde97111.948000079-02-7 Sustainability 14 06540 i0041.633LLE-GC-MS
57.109Crotonaldehyde9170.042000123-73-9 Sustainability 14 06540 i0054.973LLE-GC-MS
67.2192-Butenal7470.040004170-30-3 Sustainability 14 06540 i0060.3183LLE-GC-MS
77.3352-Chloroethanol7880.003000107-07-3 Sustainability 14 06540 i0071.943LLE-GC-MS
87.808Chloroacetone8092.003000078-95-5 Sustainability 14 06540 i0080.6403LLE-GC-MS
99.3913-Penten-2-one7284.058003102-33-8 Sustainability 14 06540 i0090.253ULLE-GC-MS
109.556Aldol7888.052000107-89-1 Sustainability 14 06540 i0100.8342LLE-GC-MS
1110.6762,4-Pentanedione64100.052000123-54-6 Sustainability 14 06540 i0110.355ULLE-GC-MS
1211.7113-Furaldehyde9596.021000498-60-2 Sustainability 14 06540 i01210.23LLE-GC-MS
1312.0903-Chloropropyne5373.992000624-65-7 Sustainability 14 06540 i0134.563LLE-GC-MS
1412.430Furfural9196.021000098-01-1 Sustainability 14 06540 i0140.2763LLE-GC-MS
1514.6992-Chloromethyl-1,3-dioxolane72122.013002568-30-1 Sustainability 14 06540 i0150.405ULLE-GC-MS
1614. 841Ethanone, 1-(2-furanyl)-86110.037001192-62-7 Sustainability 14 06540 i0160.2233LLE-GC-MS
1715.1712-Acetylfuran91110.037001192-62-7 Sustainability 14 06540 i0170.1934LLE-GC-MS
1815.3115-Methyl furfural91110.037000620-02-0 Sustainability 14 06540 i01836.82LLE-GC-MS
1916.0363,3-Dimethyl-2,4-pentanedione72128.084003142-58-3 Sustainability 14 06540 i0190.474ULLE-GC-MS
2017.2852-Acetyl-5-methylfuran86124.052001193-79-9 Sustainability 14 06540 i0201.853LLE-GC-MS
2118.372CIS-1,3-Dichloropropene72109.969010061-01-5 Sustainability 14 06540 i0210.2993LLE-GC-MS
2219.4762-Dichloromethyl-1,3-dioxolane42155.974002612-35-3 Sustainability 14 06540 i0220.152ULLE-GC-MS
2320.4051-Octanol42130.14000111-87-5 Sustainability 14 06540 i0230.07372LLE-GC-MS
2421.2763-Methyl-2-cyclohexen-1-one47110.073001193-18-6 Sustainability 14 06540 i0240.2582LLE-GC-MS
2521.5061-Chloromethyl-4-methylenecyclohexane50144.071000823-83-6 Sustainability 14 06540 i0250.663ULLE-GC-MS
2623.2995-chloro-2-methoxy-phenol50158.013003743-23-5 Sustainability 14 06540 i0260.368ULLE-GC-MS
2725.2315-chlorobenzene-1,3-diol72143.998005278-23-1 Sustainability 14 06540 i0270.249ULLE-GC-MS
2826.3864-Chlorophenetole38156.034000622-61-7 Sustainability 14 06540 i0280.166ULLE-GC-MS
295. 072Acetaldehyde5944.026000075-07-0 Sustainability 14 06540 i0292.463Purge and trap-GC/MS
305.276Ethyl alcohol8046.042000064-17-5 Sustainability 14 06540 i0303.332Purge and trap-GC/MS
a Toxicity grade-“U”: unknown; “0”: non-toxic, LD50 > 15 g/kg; “1”: actual non-toxicity, 5 g/kg < LD50 < 15 g/kg; “2”: low toxicity, 0.5 g/kg < LD50 < 5 g/kg; “3”: medium toxicity, 50 mg/kg < LD50 < 500 mg/kg; “4”: high toxicity, LD50 < 50 mg/kg. The above toxicity data were all tested in rats.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Yang, Y.; Yu, Y.; Zhou, J.; Xi, H.; Wang, C.; Zhou, Y.; Fu, L.; Qi, Y.; Yuan, Y. Characterization and Analysis of Acetaldehyde Wastewater by Molecular Weight Distribution, Hydrophilicity, and Chemical Composition. Sustainability 2022, 14, 6540. https://doi.org/10.3390/su14116540

AMA Style

Yang Y, Yu Y, Zhou J, Xi H, Wang C, Zhou Y, Fu L, Qi Y, Yuan Y. Characterization and Analysis of Acetaldehyde Wastewater by Molecular Weight Distribution, Hydrophilicity, and Chemical Composition. Sustainability. 2022; 14(11):6540. https://doi.org/10.3390/su14116540

Chicago/Turabian Style

Yang, Yang, Yin Yu, Jingling Zhou, Hongbo Xi, Chunrong Wang, Yuexi Zhou, Liya Fu, Yue Qi, and Yue Yuan. 2022. "Characterization and Analysis of Acetaldehyde Wastewater by Molecular Weight Distribution, Hydrophilicity, and Chemical Composition" Sustainability 14, no. 11: 6540. https://doi.org/10.3390/su14116540

APA Style

Yang, Y., Yu, Y., Zhou, J., Xi, H., Wang, C., Zhou, Y., Fu, L., Qi, Y., & Yuan, Y. (2022). Characterization and Analysis of Acetaldehyde Wastewater by Molecular Weight Distribution, Hydrophilicity, and Chemical Composition. Sustainability, 14(11), 6540. https://doi.org/10.3390/su14116540

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop