Influence of LiDAR Point Cloud Density in the Geometric Characterization of Rooftops for Solar Photovoltaic Studies in Cities

by
María Sánchez-Aparicio
*,
Susana Del Pozo
,
Jose Antonio Martín-Jiménez
,
Enrique González-González
,
Paula Andrés-Anaya
and
Susana Lagüela
Department of Cartographic and Land Engineering, University of Salamanca, Hornos Caleros, 50, 05003 Ávila, Spain
*
Author to whom correspondence should be addressed.
Remote Sens. 2020, 12(22), 3726; https://doi.org/10.3390/rs12223726
Submission received: 27 October 2020 / Revised: 10 November 2020 / Accepted: 11 November 2020 / Published: 13 November 2020
(This article belongs to the Special Issue Renewable Energy Mapping)

Abstract

:
The use of LiDAR (Light Detection and Ranging) data for the definition of the 3D geometry of roofs has been widely exploited in recent years for its posterior application in the field of solar energy. Point density in LiDAR data is an essential characteristic to be taken into account for the accurate estimation of roof geometry: area, orientation and slope. This paper presents a comparative study between LiDAR data of different point densities: 0.5, 1, 2 and 14 points/m2 for the measurement of the area of roofs of residential and industrial buildings. The data used for the study are the LiDAR data freely available by the Spanish Institute of Geography (IGN), which is offered according to the INSPIRE Directive. The results obtained show different behaviors for roofs with an area below and over 200 m2. While the use of low-density point clouds (0.5 point/m2) presents significant errors in the estimation of the area, the use of point clouds with higher density (1 or 2 points/m2) implies a great improvement in the area results, with no significant difference among them. The use of high-density point clouds (14 points/m2) also implies an improvement of the results, although the accuracy does not increase in the same ratio as the increase in density regarding 1 or 2 points/m2. Thus, the conclusion reached is that the geometrical characterization of roofs requires data acquisition with point density of 1 or 2 points/m2, and that higher point densities do not improve the results with the same intensity as they increase computation time.

Graphical Abstract

1. Introduction

There has been an exponential increase in the global population in recent years [1]. This population growth implies an increase in the needs for transport, electricity, and air conditioning [2]. Another characteristic of the demographic changes is the abandonment of rural areas in favor of cities [3], in such a way that cities become the main points of consumption. According to the United Nations [4], it is estimated that 66% of the world population will live in urban zones in 2050. Regarding cities, buildings are the origin of 40% of the total energy consumption and 36% of CO2 emissions in Europe [5]. Regulations state that these values must be reduced through the increase in energy efficiency and the incorporation of sustainable energy resources, such as renewable energies [6].
Among renewable energies, solar energy has suffered the highest increase, 28% increase between 2017 and 2020 [7], due to its adequacy for generation at small-scale (self-consumption). This increase is a result of the effort made for the integration of solar energy in cities, which has been accompanied by a high number of scientific publications regarding photovoltaic solar energy in cities [8]. Existing studies cover topics from the development of new energy storage techniques [9], methodologies for building [10] or façade [11] detection, to the development of parameters involved in the computation of solar potential [12] and of computation tools [13]. Many studies have focused on the automation of the different processes: automatic computation of solar potential [13], or automatic roof detection [14].
Throughout the last few years, the growing interest in roofs for energy generation has been shown in the appearance of a high number of scientific works in the topic [13,15] and about the contribution of roofs for mitigation of heat accumulation (green roofs) [16]. The automatic detection of roofs is one of the most active research lines in the current years, mainly focusing on the development of strategies from the processing of point clouds acquired with aerial LiDAR based on advanced descriptors [17], on Deep Learning strategies [18], on 3D voxels [19], and in 2D feature extraction [20]. Other studies focus on the combination of LiDAR data with aerial imagery for the detection of all types of roofs [21]. However, most studies deal with 3D modelling of roofs using plane detection and edge outlining [17,22]. Nguyen et al. (2012) [23] show a good example of the utility of point clouds for the estimation of solar power due to the availability of the building height within their data. In addition to building height, other parameters such as roof orientation, roof slope and area available are required for the computation of the energy that can be generated on roofs [24]. The parameters of roof orientation and roof slope can be accurately determined from point clouds, while the computation of the area does not present the same accuracy with aerial LiDAR [25]. One strategy for the computation of the area of roofs from point clouds is through outlining the building [26]. The level of accuracy in the computation of the area is determined by the density of the point cloud and by the regularity of the point distribution in case that density is not uniform through the point cloud. The work developed by Martín-Jiménez et al. (2020) [25] defends the need for the combination of aerial imagery with LiDAR data for the accurate computation of all the parameters of the roof.
However, a high-density point cloud allows the accurate computation of the area of the roof since the building can be accurately outlined from these data. However, a higher density implies a higher number of points and therefore an increase in processing time of the roof detection and parameterization. In this context, two questions arise: Which is the minimum point density that allows an accurate computation of the area of a roof without an excessive processing time? How does the accuracy reached influence the computation of solar potential? The influence of the density of the point cloud has been analyzed in other applications [27,28,29]. However, in the solar energy field, point cloud density has only been considered as a variable in the performance of different modelling strategies [30], and in density-based strategies to detect roofs [31]. Regarding the analysis of the influence of the density of point clouds on the geometric parameterization results of the roofs, a study has been recently published [32]. Their focus is set on high-density point clouds generated from photogrammetric flights, in such a way that the limitations implied in LiDAR data, such as noise or lack of points in reflective materials, are not incorporated into the analysis.
The automation on the process of roof detection and geometric characterization with geospatial data allows the massive computation of solar potential in big extensions. In the case of Europe, the INSPIRE Directive [33] provides standard geospatial data within the European community. Germany and France are the countries with the most abundant INSPIRE resources available to download. However, aerial imagery or LiDAR data that could be used for the computation of solar potential are only available for some regions. In the case of Spain, the number of geospatial data is lower, but these include orthoimagery and LiDAR data covering the whole territory. These data are acquired by the Spanish National Geographic Institute (from now on, IGN) and present different resolutions. For example, for LiDAR data, the resolutions are between 0.5 points/m2 and 14 points/m2. The availability of free data with different densities is the reason for the selection of Spain as provider of cases of study for the performance of the density analysis. The paper is structured in six sections. After this review of the state of the art regarding the geometric characterization of roofs with geomatic data, the data used and the methodology followed in the study are presented in Section 2. Section 3 details the cases study chosen for the application of the methodology. The results obtained are shown in Section 4 with the application of them to the analysis of photovoltaic (PV) energy production in Spain. These results are discussed in Section 5. The conclusions reached after the study are summarized in Section 6.

2. Materials and Methods

In order to evaluate the influence of the density of LiDAR point clouds in estimating the area, data from the IGN have been used. As case studies, different cities in Spain with different point cloud densities have been selected. However, the study is performed in such a way that the location of the case studies is not relevant to the results, so that these can be considered as a guide for those countries where LiDAR data are not available, in such a way that the geometric requirements are clear for the optimal investment in equipment when geometric data are to be provided.

2.1. Geospatial Data: Spanish National Geographic Institute

The IGN is a public agency from the Ministry of Transports, Mobility and Urban Agenda (Government of Spain), responsible for measuring and compiling data of the Earth’s surface [34], which is made publicly available [35]. The compilation includes updated geographic data in all the territory of Spain, following the INSPIRE European Directive: topographic data in vector and raster format at different scales and thematic geographic data such as land cover/use [36].
The main product offered by IGN is aerial photography. This product is used as the basis for the generation of most of the cartographic products offered. The PNOA Project (which stands for National Plan for Aerial Orthophotography) [37] consists of the periodic acquisition of the territory of Spain with aerial photography. It has been active from the year 2004. PNOA implies the acquisition of images with a temporal resolution of 2–3 years. The main product derived from the aerial images is the aerial orthophotography, which has the main characteristic of spatial resolution: 25 or 50 cm (Table 1). Aerial orthophotographs from PNOA are georeferenced to the Spanish Reference Coordinate System [38]: ETRS89 in the Iberian Peninsula and REGCAN95 for the Canary Islands. The aerial orthophotographs are used in this work as a reference and ground-truth for the evaluation of geometry, due to its high spatial resolution. This work uses orthophotographs from the year 2017.
In 2008, the PNOA Project included the acquisition of geometric data with LiDAR sensors, with the aim of increasing the accuracy of Digital Terrain Models. This led to the creation of the PNOA-LiDAR Project [39]. LiDAR data are acquired across all territory every 2 or 3 years. Currently, two different LiDAR coverage sets coexist (Figure 1). The first coverage started in 2008 and finished in 2015. Data acquisition had a minimum point cloud density of 0.5 point/m2 and elevation accuracy (RMSEz o Root Mean Square Error in the elevation axis (the z-axis)) between 0.20 and 0.40 m (Table 2). From 2015 up to now, data are being acquired for the second coverage, with a minimum point cloud density of 1 point/m2 and elevation accuracy (RMSEz) between 0.15 and 0.20 m (Table 2). PNOA-LiDAR data have the same coordinate reference system as the aerial orthophotographs.
In addition, the points in the point clouds are classified according to the classification from the American Society for Photogrammetry and Remote Sensing (ASPRS) [40], following a methodology presented in [41] that shows that the performance of the classification for points of the class “buildings” is over 90%. For this reason, the classification provided by the dataset is exploited in this study for the analysis of rooftop area.

2.2. Methodology

The methodology proposed consists of computing the area of the rooftops in point clouds with different densities, with the aim of evaluating the influence of the density in the accuracy of the area estimated. For this purpose, it is necessary to use aerial orthophotography as reference data. This kind of data is selected due to its planimetric precision. For both cases, the methodology consists of two main stages (Figure 2). The first one to prepare the buildings (Figure 3) and the second one to compute the area.

2.2.1. Aerial Orthophotography

A reference value of the area is required in order to calculate the error of the estimation of the area from the point cloud. Although the most accurate procedure would imply the measurement of the areas with classical surveying, the high number of rooftops included in the study and their separate locations make the use of geospatial data necessary. In particular, in this study, the aerial orthophotography with 25 cm spatial resolution is established as reference, since it is the highest resolution data available from all the case studies.
The computation of the area of roofs from orthophotographs requires a digitalization process. In this case, manual digitalization of the roofs is performed using QGIS software [42], where the rooftops are delineated into a shapefile (Figure 4a). Thanks to the different tools of QGIS, it is possible to calculate automatically the area of the shapefile elements. It should be highlighted that the orthophotography is a planimetric product, and consequently the area calculated is the projected area (2 dimensions).

2.2.2. LiDAR Point Cloud

In order to calculate the area using the LiDAR data of each of the buildings selected for the study, it is necessary to know the points that belong to the roofs (Figure 3). Although the LiDAR point cloud offered by IGN is classified according to the ASPRS, further processing is required. This processing has been automated using MATLAB®, and consists of the following steps, that are further detailed in [25]:
  • Removal of points belonging to the ground and part of vegetation. The first step relies on the classification of the point cloud in ASPRS classes. Those points with a single LiDAR return and with a different classification than class 2 (ground) continue in the process. In this way, the process not only ensures the elimination of points belonging to the ground but also part of the points belonging to vegetation (Figure 3b).
  • Removal of remaining points belonging to vegetation areas. A previous computation of the Normalized Vegetation Index (NDVI) [43] is required, using the red and near infrared information collected by the LiDAR and applying Equation (1).
    NDVI = NIR RED NIR + RED ,    where ( 1 < NDVI < 1 )
    A NDVI threshold of 0.3 [43,44] was established in such a way that points with higher NDVI value are considered vegetation and consequently removed (Figure 3c).
  • Removal of points belonging to building façades. This segmentation is based on the Z-component of the normal vector (Nz) of each 3D point. Each normal vector is estimated through the adjustment of a 2D subspace that is tangent at the point of interest based on pairwise point relationships [45]. Specifically, a surface is adjusted to the 8 nearest neighbor points of each 3D analyzed point (search resolved by k-d tree) within a maximum radius of 4 m. In this calculation, the covariance matrix of the 8 points is analyzed and the normal vector of the surface adjusted is determined as the normal vector of the analyzed point. A threshold of 0.15 was established in such a way that any point with a Nz value below the threshold is considered a point corresponding to façades (Figure 3d).
  • Removal of noise points. Possible residual points from the previous steps (such as ground points with a single LiDAR return that pass the first filter) are deleted by applying a statistical outlier removal (SOR) filter [46]. A threshold of 1 m deviation in 30 neighbor points was established. After this step, the resulting point cloud corresponds only to roof areas (Figure 3e).
Once the point cloud only contains points belonging to the roofs of the buildings (Figure 3e), the area is calculated. Notice that LiDAR point data are a 3D product while the reference data (orthophotography) are a 2D product. Due to this difference, the comparison of the results between both products requires the dismissal of the third dimension from the point cloud (projected area) (Figure 4).
In computational geometry, there are different methods of boundary extraction that allow the automatic computation of the area contained in a set of points [47]. The most known technique is the convex hull [48]. There are many methods derived from this technique. Some of them are Alpha shape [49] and concave hull [50]. The main difference between these methodologies and the convex hull methodology is the closure form. While the convex hull is a technique that allows a convex enclosure on a set of points, alpha shape and concave hull allow a non-convex enclosure. For the first of the cases, this involves an over-estimation while the second involves an under-estimation in the computation of the area. With the aim at estimating the area contained in a set of points, an intermediate function between all the previous methodologies has been used. Specifically, the “Boundary” function, which is implemented in MATLAB®. Unlike the convex hull, the boundary can shrink towards the interior of the hull to envelop the points [51]. Thus, the user can specify a shrink factor “s”. This is a scalar factor between 0 and 1. If s = 0, this function gives the convex hull. On the other hand, if s takes the value of 1, the result is a compact boundary. For this case, the value of the shrink factor is 0.5 (default value).

3. Case Studies

Industrial and residential buildings were selected for the computation of the area of their rooftops (Figure 5) with the methodology proposed in Section 2 and for the evaluation of the influence of the point cloud density on the accuracy of the computation. The study analyzes industrial and residential buildings separately because the first present regular geometry, mostly rectangular, while the second usually present complex and irregular geometries, with more than four edges and angles (Figure 6; Figure 7). To make the study as homogeneous as possible, a total of 120 industrial buildings and 95 residential buildings were selected (Table 3) with a wide range of areas, from 27 m2 to 3000 m2 (Figure 5).
In the experiments, LiDAR datasets with density of 0.5, 1, 2 and 14 point/m2 were used. The equipment used for the data collection is different and therefore impacts the RMSE. For the first coverage, the equipment used in two of the three cases is the same and the RMSEs (RMSE xy and RMSE z) are the same (Table 4). Although for the second coverage of LiDAR data the equipment is the same, for case 1 and case 2 the RMSEs are not the same (Table 5).
The orthophotographs used for the computation of the projected area used as reference present the same technical specifications for all the cases of study (Table 2). Although flight pixel size is 35 cm for case 1 and 22 cm for cases 2 and 3, all the orthophotographs generated present the same pixel size of 25 cm. All the orthophotographs were acquired under favorable meteorological conditions, as shown in Figure 6; Figure 7, which include an example of the buildings subjected to the study.

4. Results

4.1. Building Boundary Extraction from Different Point Densities

The methodology for the computation of the projected area (of reference and from point cloud) is applied to all the cases of study (Figure 8). The different values of the projected area were computed from the different point cloud densities towards the analysis of the influence of the density on the accuracy of the projected area calculated.
The error of the area computed from each point cloud density is calculated, using as reference the area value from the orthophotographs: the error of the area is the result of the intersection between the reference area (green line in Figure 8) and the extracted contour (red line in Figure 8) per building. Relative error results show an inflexion point for areas of 200 m2: all buildings under study with an area below 200 m2 present a higher error value in the computation of the area than the buildings with an area over 200 m2 (Figure 9). This result appears for both residential and industrial buildings, and for all point cloud densities considered in the study.
When the average RMSE is calculated for the buildings under study (Table 6; Table 7), the results are opposite to the relative error. This is because the relative error shows the relative difference expressed in % while RMSE shows the area difference in m2.
For the different point cloud densities, the lowest point cloud density (0.5 point/m2) presents the highest error for all cases: relative error reaches values of 24–30% with an RMSE between 26 and 30 m2 for buildings under 200 m2, and 12–15% with an RMSE between 68 and 88 m2 for buildings over 200 m2.
When point cloud density is double (1 point/m2), the relative error decreases to 18% for buildings under 200 m2 and 7% for buildings over 200 m2. The point cloud density of 2 points/m2 presents similar values of relative error, although density is double than point clouds with 1 point/m2.
The results for point cloud density of 14 points/m2 present lower error than for lower point cloud densities. In this case, the relative error value does not present a difference with the area of the building: the relative error is 6% for residential buildings and 3% for industrial buildings.
For an average building of each type (residential and industrial), the mean computation time for each point cloud density using a notebook with Intel Core i7-6700 processor at 3.41 GHz, 64 bits, 32 Gb. RAM and 931 Gb. disk is shown in Table 8 and Table 9.
In addition to the relative error in the roof surface computed with LiDAR data, there are other metrics to be taken into account for the evaluation of the validity of LiDAR for roof characterization. These metrics are precision, recall, and F-score [52] defined as follows:
Precision =   T P T P + F P
Recall =   T P T P + F N
F score =   2 P r e c i s i o n R e c a l l P r e c i s i o n + R e c a l l
where TP, FP and FN are the number of true positives, false positives, and false negatives, respectively.
The mean values for Recall and F-score are shown in Figure 10 and Figure 11 according to the different point cloud densities and the use of the building. In the conducted experiments, the precision metrics always reach 100%, since the methodology avoids false positives in boundary extraction.

4.2. Influence of the Error in Area on the Computation of PV Energy Production

The design of a solar PV installation on a rooftop requires the knowledge of geometric parameters of the rooftop, among which the area is included [25]. For this reason, the error in the computation of the area of the rooftop will have an influence on the computation of the total solar potential of the rooftop.
Provided that the buildings selected as cases of study are located in Spain, the influence of the area on the solar potential is computed for this location. In all cases, the solar radiation is computed for panels with South orientation, and optimal tilt angle. In this way, the only cause of difference is the error in the area computed. In order to correlate incoming solar radiation with solar potential, PV panels of 330 W are considered. It should be highlighted that this and all further assumptions are equally applied to all the cases of study, in a way to validate the relative comparison.
According to the Spanish Technical Construction Code [53], Spain has five solar climate zones (Figure 12); their average daily solar radiation values are shown in Table 10.
Five cities distributed by the different climatic zones were selected (Table 11) for the performance of the analysis of the effect of the error in the computation of the usable area of the rooftop, in such way that the effect is analyzed for a wide range of solar intensities. The solar radiation value was obtained through the “Solar radiation tool” offered by PVGIS (PhotoVoltaic Geographic Information System) [54] considering the average altitude of each of the cities (Table 11), a South orientation and an optimal tilt angle.
The error analysis was performed for both residential and industrial buildings with a projected rooftop area of 100 m2, representing buildings under 200 m2, and a projected rooftop area of 400 m2 as the example of buildings with an area over 200 m2. In the case of industrial buildings, which present mostly gable roofs, the computation was performed, taking into account the installation of the solar PV panels only in the slopes with South orientation. Thus, 50% of the total area of the rooftop is considered for the computation of the number of panels and of the solar potential. In the case of flat roofs, which are also common among industrial buildings, the reduction in the usable area is applied to consider the tilt angle of the panels and the space needed between panels in order to avoid the projection of shadows.
Table 12, Table 13, Table 14 and Table 15 present the solar power losses produced by the errors in the estimation of the area of the rooftop in industrial buildings with gable or flat roof.
Gable or hipped roofs are the most common in residential buildings. For this reason, only 50% of the projected area has been considered as usable area for gable roofs, considering that one slope is South-oriented and that is the slope where the PV panels are installed. In the case of hipped roofs there is no standard regarding area of each slope and the total area of the rooftop, in such a way that the study was performed installing the PV panels on the 33% of the total area.
Table 16, Table 17, Table 18 and Table 19 show the losses in the solar potential due to the error in the computation of the area of the rooftop from LiDAR data with different point cloud densities for residential buildings, which present gable or hipped roofs.

5. Discussion

The point cloud density that produces the highest error in the computation of the projected rooftop area is 0.5 point/m2; in this case, the error for buildings smaller than 200 m2 is 30% of the total area. The improvement on the computation of the projected area with double point cloud density (1 point/m2) is an 8% reduction in the error, although the next doubling, from 1 to 2 points/m2, does not imply any great improvement: the error increases of 2%. The use of a point cloud density seven times higher, with 14 points/m2, implies a reduction in the error of 12% for buildings smaller than 200 m2 and 6% for bigger buildings. However, the improvement is less intense than the improvement in the difference between point cloud densities. This difference in intensity of improvement is shown in Figure 13: the error reduction for the doubling of point cloud density from 0.5 to 1 point/m2 has a mean value of 58% in a graphical representation (30° slope) for all building cases, while the doubling from 1 to 2 points/m2 presents a flat or an uphill difference in the value of the relative error; thus, no reduction in error is associated with this improvement of point cloud density. The density increases from 2 to 14 points/m2 generate a mean reduction in the relative error of 1.12%: the mean slope value in the graphic representation of the error is 4% (2°).
A trend can be extracted regarding residential and industrial buildings: the first result in a higher error than the second, probably caused by the higher angle of the roof slope. The exception is found for buildings smaller than 200 m2 and point cloud density of 0.5 point/m2. In this case, the error in the computation of the projected area is smaller for residential buildings than for industrial buildings, with 5% difference.
However, not only the computation but the relative error in the estimation of the area shows that the lowest point cloud density (0.5 point/m2) presents a higher error than the rest of the densities. Buildings with an area less than 200 m2 have recall and f-score lower than buildings with an area greater than 200 m2. Factors that, for the case of point cloud of 1 and 2 points/m2, barely show variations. Point clouds with the higher density (14 points/m2) present a recall and f-score value very close to 100%. As the methodology does not classify points as false positives, the precision in all the cases is at 100%.
With respect to PV energy production per square meter loss, due to the computation of the area with point cloud data, Figure 14, Figure 15, Figure 16 and Figure 17 show the RMSE daily PV energy production per square meter loss.
Industrial buildings with flat roofs suffer a PV energy production per square meter loss between 613 and 870 Wh/m2. The PV energy production per square meter loss for industrial buildings with gable roof is between 397 and 846 Wh/m2.
Residential buildings with gable roofs suffer a PV energy production per square meter loss between 453 and 914 Wh/m2. The PV energy production per square meter loss for residential buildings with hipped roofs is between 582 and 924 Wh/m2.
If the focus is set on the different solar climate zones, the results are grouped: values of solar power loss are almost equal for solar climate zones 1 or 2 (mean annual solar radiation between 3.8 kWh/m2 and 4.2 kWh/m2), and for solar climate zones 3 and 4 (ranging between 4.2 kWh/m2 and 5 kWh/m2). In general, there is a difference of 100 Wh/m2 loss between each of the groups: 600 Wh/m2 (zone 1 and zone 2), 700 Wh/m2 (zone 3 and zone 4) and 800 Wh/m2 (zone 5).

Results Regarding Other Density Analysis

Drešček has also performed a quality analysis of building outline extraction for different point cloud densities [32]. For this case, the analyzed point cloud comes from a photogrammetric flight carried out with UAV (Unmanned Aerial Vehicles) with 1, 2.5, 5, 10 and 20 cm. point spacing (that is, point cloud densities of 10,000, 1600, 400, 100 and 25 points/m2, respectively). Table 20 shows the results obtained from a direct approach. The variation of the three quality parameters evaluated is practically visible.
Comparing the results of Table 20 with those obtained for the point clouds evaluated in this article (Figure 10; Figure 11), it can be observed that the point cloud with 14 points/m2 has a very similar recall and f-score values to the point cloud with a 20 cm point spacing (25 points/m2). From this comparison, it can be deduced that a significant improvement of the results does not require a significant increase in the point cloud density.

6. Conclusions

The exhaustive analysis of the point cloud density allows the determination of the accuracy of the geometric characterization of the rooftops performed from point cloud data, and of the subsequent simulation of the energy production in the roof. The results of the analysis have shown that the highest accuracy range is obtained from point cloud densities of 1 or 2 points/m2, especially in buildings with an area bigger than 200 m2, both residential and industrial. Lower densities present an important decrease in accuracy (50% when using point cloud density of 0.5 point/m2). Higher densities increase the accuracy, but the improvement is not as intense as the increase in computation time (1.12% increase in accuracy vs. mean increase in computation time from 13 s to 90 s (14.45% time increase) working with point cloud density of 14 points/m2 instead of 2 points/m2). A density greater than 14 points/m2 does not improve the quality of the final results to the same extent as the increase in the number of points of the point cloud. In addition, it can be seen that the shape of the roof (gable or hipped roofs) does not influence in the accuracy of the determination of the area.
Although the computation of the rooftop area contains the whole building, solar PV panels are usually not installed in all the usable area. Panels are mostly installed in the slopes of the rooftop with the highest incoming solar radiation. That is, South orientation in the North hemisphere, and North orientation in the South hemisphere. Taking this fact into account, the percentage in error on the computation of the area and on the simulation of energy production per square meter is equal for the complete roof than for part of it. In this case, the essential factor is the incoming solar radiation. An analysis of the five solar climate zones in Spain has shown that the higher the incoming solar radiation on the rooftop, the higher the loss on solar power provoked by the error in the computation of the area. This is an important factor when translating the results of the study to countries with lower solar radiation than Spain: the same point cloud densities for the computation of the rooftop area will provoke lower error in the simulation of the solar power per square meter.
Future studies will deal with the analysis of point cloud densities different from those analyzed in this study. Effort will be put on point cloud densities between 2 and 14 points/m2, with the aim of reducing the gap of knowledge between these values, and to determine the highest point cloud density that allows the geometric characterization of the roof optimizing accuracy and computation time. This study will be possible when data from the last flights performed by IGN are made available, with a point cloud density of 4 points/m2.

Author Contributions

Conceptualization, M.S.-A. and S.L.; methodology, M.S.-A., S.D.P.; software, S.D.P., J.A.M.-J.; validation, M.S.-A.; investigation, E.G.-G.; data curation, P.A.-A.; writing—original draft preparation, M.S.-A.; writing—review and editing, S.L.; project administration, S.L.; funding acquisition, S.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Cátedra Iberdrola VII Centenary of the University of Salamanca. The authors would like to thank Iberdrola S.D.P. and the University of Salamanca.

Acknowledgments

We also express our gratitude to the Ministry of Science, Innovation, and Universities for the funding given for the project RTC-2017-6291-3.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Population Division, Department of Economic and Social Affairs, United Nations. World Population Prospects 2019: Highlights (ST/ESA/SER.A/423); United Nations: New York, NY, USA, 2019. [Google Scholar]
  2. Holmberg, K.; Erdemir, A. Influence of tribology on global energy consumption, costs and emissions. Friction 2017, 5, 263–284. [Google Scholar] [CrossRef]
  3. Albouy, D.; Behrens, K.; Robert-Nicoud, F.; Seegert, N. The optimal distribution of population across cities. J. Urban Econ. 2019, 110, 102–113. [Google Scholar] [CrossRef]
  4. Population Division, Department of Economic and Social Affairs, United Nations. World Urbanization Prospects: The 2011 Revision (ST/ESA/SER.A/322); United Nations: New York, NY, USA, 2012. [Google Scholar]
  5. European Commission. Communication from the commission to the European Parliament, the European Council, the Council, the European Economic and Social Committee and the Committee of Regions. In The European Green Deal; European Commission: Brussels, Belgium, 2019. [Google Scholar]
  6. Gielen, D.; Boshell, F.; Saygin, D.; Bazilian, M.D.; Wagner, N.; Gorini, R. The role of renewable energy in the global energy transformation. Energy Strat. Rev. 2019, 24, 38–50. [Google Scholar] [CrossRef]
  7. International Renewable Energy Agency. Renewable Energy Highlights; International Renewable Energy Agency: Abu Dhabi, UAE, 2019. [Google Scholar]
  8. Brito, M.C.; Redweik, P.; Catita, C.; Freitas, S.; Santos, M. 3D Solar Potential in the Urban Environment: A Case Study in Lisbon. Energies 2019, 12, 3457. [Google Scholar] [CrossRef] [Green Version]
  9. Behzadi, A.; Arabkoohsar, A. Feasibility study of a smart building energy system comprising solar PV/T panels and a heat storage unit. Energy 2020, 210, 118528. [Google Scholar] [CrossRef]
  10. Gonzalez, D.; Rueda-Plata, D.; Acevedo, A.B.; Duque, J.C.; Ramos-Pollán, R.; Betancourt, A.; García, S. Automatic detection of building typology using deep learning methods on street level images. Build. Environ. 2020, 177, 106805. [Google Scholar] [CrossRef]
  11. Saretta, E.; Bonomo, P.; Frontini, F. A calculation method for the BIPV potential of Swiss façades at LOD2.5 in urban areas: A case from Ticino region. Sol. Energy 2020, 195, 150–165. [Google Scholar] [CrossRef]
  12. Prieto, I.; Izkara, J.L.; Usobiaga, E. The Application of LiDAR Data for the Solar Potential Analysis Based on Urban 3D Model. Remote. Sens. 2019, 11, 2348. [Google Scholar] [CrossRef] [Green Version]
  13. Sánchez-Aparicio, M.; Martín-Jiménez, J.; Del Pozo, S.; González-González, E.; Lagüela, S. Ener3DMap-SolarWeb roofs: A geospatial web-based platform to compute photovoltaic potential. Renew. Sustain. Energy Rev. 2021, 135, 110203. [Google Scholar] [CrossRef]
  14. Tiwari, A.; Meir, I.A.; Karnieli, A. Object-Based Image Procedures for Assessing the Solar Energy Photovoltaic Potential of Heterogeneous Rooftops Using Airborne LiDAR and Orthophoto. Remote. Sens. 2020, 12, 223. [Google Scholar] [CrossRef] [Green Version]
  15. De Vries, T.N.; Bronkhorst, J.; Vermeer, M.; Donker, J.C.; Briels, S.A.; Ziar, H.; Zeman, M.; Isabella, O. A quick-scan method to assess photovoltaic rooftop potential based on aerial imagery and LiDAR. Sol. Energy 2020, 209, 96–107. [Google Scholar] [CrossRef]
  16. Asadi, A.; Arefi, H.; Fathipoor, H. Simulation of green roofs and their potential mitigating effects on the urban heat island using an artificial neural network: A case study in Austin, Texas. Adv. Space Res. 2020, 66, 1846–1862. [Google Scholar] [CrossRef]
  17. Widyaningrum, E.; Peters, R.Y.; Lindenbergh, R. Building outline extraction from ALS point clouds using medial axis transform descriptors. Pattern Recognit. 2020, 106, 107447. [Google Scholar] [CrossRef]
  18. Yang, B.; Zanchetta, C.; Previtali, M.; Della Torre, S. Detection of Building Roofs and Facades from Aerial Laser Scanning Data Using Deep Learning. ISPRS—Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci. 2019, 42, 975–980. [Google Scholar] [CrossRef] [Green Version]
  19. Wang, L.; Xu, Y.; Li, Y. A Voxel-Based 3D Building Detection Algorithm for Airborne LIDAR Point Clouds. J. Indian Soc. Remote Sens. 2018, 47, 349–358. [Google Scholar] [CrossRef]
  20. Widyaningrum, E.; Gorte, B.; Lindenbergh, R. Automatic Building Outline Extraction from ALS Point Clouds by Ordered Points Aided Hough Transform. Remote Sens. 2019, 11, 1727. [Google Scholar] [CrossRef] [Green Version]
  21. Siddiqui, F.U.; Teng, S.; Awrangjeb, M.; Lu, G. A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery. Sensors 2016, 16, 1110. [Google Scholar] [CrossRef] [Green Version]
  22. Gilani, S.A.N.; Awrangjeb, M.; Lu, G. Segmentation of Airborne Point Cloud Data for Automatic Building Roof Extraction. GISci. Remote Sens. 2017, 55, 63–89. [Google Scholar] [CrossRef] [Green Version]
  23. Nguyen, H.T.; Pearce, J.M.; Harrap, R.; Barber, G. The Application of LiDAR to Assessment of Rooftop Solar Photovoltaic Deployment Potential in a Municipal District Unit. Sensors 2012, 12, 4534–4558. [Google Scholar] [CrossRef]
  24. Le, T.B.; Kholdi, D.; Xie, H.; Dong, B.; Vega, R. LiDAR-Based Solar Mapping for Distributed Solar Plant Design and Grid Integration in San Antonio, Texas. Remote Sens. 2016, 8, 247. [Google Scholar] [CrossRef] [Green Version]
  25. Martín-Jiménez, J.; Del Pozo, S.; Sánchez-Aparicio, M.; Lagüela, S. Multi-scale roof characterization from LiDAR data and aerial orthoimagery: Automatic computation of building photovoltaic capacity. Autom. Constr. 2020, 109, 102965. [Google Scholar] [CrossRef]
  26. Sampath, A.; Shan, J. Building Boundary Tracing and Regularization from Airborne Lidar Point Clouds. Photogramm. Eng. Remote Sens. 2007, 73, 805–812. [Google Scholar] [CrossRef] [Green Version]
  27. Singh, K.K.; Chen, G.; McCarter, J.B.; Meentemeyer, R.K. Effects of LiDAR point density and landscape context on estimates of urban forest biomass. ISPRS J. Photogramm. Remote Sens. 2015, 101, 310–322. [Google Scholar] [CrossRef] [Green Version]
  28. Agüera-Vega, F.; Agüera-Puntas, M.; Martínez-Carricondo, P.; Mancini, F.; Carvajal-Ramírez, F. Effects of point cloud density, interpolation method and grid size on derived Digital Terrain Model accuracy at micro topography level. Int. J. Remote Sens. 2020, 41, 8281–8299. [Google Scholar] [CrossRef]
  29. Li, Y.; Wu, B.; Ge, X. Structural segmentation and classification of mobile laser scanning point clouds with large variations in point density. ISPRS J. Photogramm. Remote Sens. 2019, 153, 151–165. [Google Scholar] [CrossRef]
  30. Dey, E.K.; Awrangjeb, M.; Stantic, B. Outlier detection and robust plane fitting for building roof extraction from LiDAR data. Int. J. Remote Sens. 2020, 41, 6325–6354. [Google Scholar] [CrossRef]
  31. Albano, R. Investigation on Roof Segmentation for 3D Building Reconstruction from Aerial LIDAR Point Clouds. Appl. Sci. 2019, 9, 4674. [Google Scholar] [CrossRef] [Green Version]
  32. Drešček, U.; Kosmatin Fras, M.; Lisec, A.; Grigillo, D. The impact of point cloud density on building outline extraction. Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci. 2020, 43, 407–413. [Google Scholar] [CrossRef]
  33. Bartha, G.; Kocsis, S. Standardization of geographic data: The european INSPIRE directive. Eur. J. Geogr. 2011, 2, 79–89. [Google Scholar]
  34. España Real Decreto 663/2007. de 25 de mayo, por el que se aprueba el Estatuto del Centro Nacional de Información Geográfica. In Boletín Oficial del Estado; Government of Spain: Madrid, Spain, 2007; pp. 1–11. [Google Scholar]
  35. Instituto Geográfico Nacional Centro de Descargas del CNIG (IGN). Available online: https://centrodedescargas.cnig.es/CentroDescargas/index.jsp (accessed on 3 June 2020).
  36. Valcarcel, N.; Villa, G.; Arozarena, A.; Garcia-Asensio, L.; Caballlero, M.E.; Porcuna, A.; Domenech, E.; Peces, J.J. SIOSE, a successful test bench towards harmonization and integration of land cover/use information as environmental reference data. Int. Arch. Photogramm. Remote Sens. Spat. Inf. Sci. 2008, 37, 1159–1164. [Google Scholar]
  37. Arozarena, A.; Villa, G.; Valcárcel, N. The National Aerial Ortophoto Program in Spain (PNOA). In Proceedings of the International Cartographic Conference, La Coruña, Spain, 9–16 July 2005. [Google Scholar]
  38. España Real Decreto 1071/2007. de 27 de julio, por el que se regula el sistema geodésico de referencia oficial de España. In Boletín Oficial del Estado; Government of Spain: Madrid, Spain, 2007; pp. 35986–35989. [Google Scholar]
  39. Ojeda, J.C.; Martínez, J. PNOA-LiDAR.Plan Nacional de Ortofotografía Aérea. Empleo de LiDAR en aplicaciones ambientales terrestres. In Proceedings of the XV Congreso Nacional Tecnologías de Información Geográfica, Madrid, Spain, 19–21 September 2012; pp. 19–21. [Google Scholar]
  40. Graham, L. The LAS 1.4 Specification; The American Society for Photogrammetry & Remote Sensing: Bethesda, MD, USA, 2012. [Google Scholar]
  41. Huarte, Á. Clasificación de la Cobertura LiDAR 2017 de Navarra con Inteligencia Artificial y herramientas open source. In Proceedings of the Jornadas SIG Libre SIGTE2019, Girona, Spain, 29–30 May 2019. [Google Scholar]
  42. QGIS Development Team. QGIS Development Team. QGIS geographic information system. In Open Source Geospatial Foundation Project; QGIS Development Team: Beaverton, OR, USA, 2016. [Google Scholar]
  43. Gandhi, G.M.; Parthiban, S.; Thummalu, N.; Christy, A. Ndvi: Vegetation Change Detection Using Remote Sensing and Gis—A Case Study of Vellore District. Procedia Comput. Sci. 2015, 57, 1199–1210. [Google Scholar] [CrossRef] [Green Version]
  44. Bhandari, A.; Kumar, A.; Singh, G. Feature Extraction using Normalized Difference Vegetation Index (NDVI): A Case Study of Jabalpur City. Procedia Technol. 2012, 6, 612–621. [Google Scholar] [CrossRef] [Green Version]
  45. Jordan, K.; Mordohai, P. A Quantitative Evaluation of Surface Normal Estimation in Point Clouds. In Proceedings of the 2014 ieee/rsj International Conference on Intelligent Robots and Systems, Chicago, IL, USA, 14–18 September 2014; pp. 4220–4226. [Google Scholar]
  46. Removing Outliers Using a StatisticalOutlierRemoval Filter. Available online: https://pointclouds.org/documentation/tutorials/statistical_outlier.html (accessed on 5 October 2020).
  47. Giblin, P.; De Berg, M.; Van Kreveld, M.; Overmars, M.; Schwarzkopf, O. Computational Geometry: Algorithms and Applications. Math. Gaz. 2001, 85, 175. [Google Scholar] [CrossRef]
  48. Efron, B. The convex hull of a random set of points. Biomatrika 1965, 52, 331–343. [Google Scholar] [CrossRef]
  49. Edelsbrunner, H.; Kirkpatrick, D.; Seidel, R. On the shape of a set of points in the plane. IEEE Trans. Inf. Theory 1983, 29, 551–559. [Google Scholar] [CrossRef] [Green Version]
  50. Moreira, A.; Santos, M.Y. Concave Hull: A K-Nearest Neighbours Approach for the Computation of the Region Occupied by a set of Points. In Proceedings of the 12th International Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications, Barcelona, Spain, 8–11 March 2007; Scitepress: San Francisco, CA, USA, 2007; pp. 61–68. [Google Scholar]
  51. Boundary of a Set of Points in 2D or 3D—MATLAB Boundary. Available online: https://es.mathworks.com/help/matlab/ref/boundary.html#buh3c7k-6 (accessed on 5 October 2020).
  52. Chinchor, N. MUC-4 evaluation metrics. In Proceedings of the 4th conference on Message understanding—MUC4 ’92, McLean, VA, USA, 16–18 June 1992; Association for Computational Linguistics (ACL): Stroudsburg, PA, USA, 1992; pp. 22–29. [Google Scholar]
  53. España Real Decreto 314/2006. de 17 de marzo, por el que se aprueba el Código Técnico de la Edificación. In Boletín Oficial del Estado; Government of Spain: Madrid, Spain, 2006; pp. 1–26. [Google Scholar]
  54. Huld, T.; Müller, R.; Gambardella, A. A new solar radiation database for estimating PV performance in Europe and Africa. Sol. Energy 2012, 86, 1803–1815. [Google Scholar] [CrossRef]
Figure 1. LiDAR data coverage published in the year 2020.
Figure 1. LiDAR data coverage published in the year 2020.
Remotesensing 12 03726 g001
Figure 2. Workflow of the methodology followed to evaluate the influence of the density.
Figure 2. Workflow of the methodology followed to evaluate the influence of the density.
Remotesensing 12 03726 g002
Figure 3. Point cloud filtering process: (a) original, (b) after removing points belonging to the ground, (c) after removing points belonging to vegetation areas, (d) after removing points belonging to building façades, (e) after removing noise points.
Figure 3. Point cloud filtering process: (a) original, (b) after removing points belonging to the ground, (c) after removing points belonging to vegetation areas, (d) after removing points belonging to building façades, (e) after removing noise points.
Remotesensing 12 03726 g003
Figure 4. Estimation of the projected area of a roof: (a) through the digitalization of the aerial orthophotography; (b) through the automatic computation of the boundary of the point cloud.
Figure 4. Estimation of the projected area of a roof: (a) through the digitalization of the aerial orthophotography; (b) through the automatic computation of the boundary of the point cloud.
Remotesensing 12 03726 g004
Figure 5. Projected area of reference: area distribution of the different cases of study.
Figure 5. Projected area of reference: area distribution of the different cases of study.
Remotesensing 12 03726 g005
Figure 6. Example of residential building roofs used for the evaluation of the effect of the point cloud density in the surface computation error: (a) <200 m2, (b) >200 m2.
Figure 6. Example of residential building roofs used for the evaluation of the effect of the point cloud density in the surface computation error: (a) <200 m2, (b) >200 m2.
Remotesensing 12 03726 g006
Figure 7. Example of industrial building roofs used for the evaluation of the effect of the point cloud density in the surface computation error: (a) <200 m2, (b) >200 m2.
Figure 7. Example of industrial building roofs used for the evaluation of the effect of the point cloud density in the surface computation error: (a) <200 m2, (b) >200 m2.
Remotesensing 12 03726 g007
Figure 8. Graphic results of the projected area of reference defined from aerial orthophotographs (green line) and projected area computed from point cloud (red line): (a) industrial and (b) residential.
Figure 8. Graphic results of the projected area of reference defined from aerial orthophotographs (green line) and projected area computed from point cloud (red line): (a) industrial and (b) residential.
Remotesensing 12 03726 g008
Figure 9. Mean relative error (%) for buildings with a surface < 200 m2 and > 200 m2: (a) industrial use (b) residential use.
Figure 9. Mean relative error (%) for buildings with a surface < 200 m2 and > 200 m2: (a) industrial use (b) residential use.
Remotesensing 12 03726 g009
Figure 10. Recall (%) for the different the point cloud densities depending on the use of the building and the area of the roof.
Figure 10. Recall (%) for the different the point cloud densities depending on the use of the building and the area of the roof.
Remotesensing 12 03726 g010
Figure 11. F-score (%) for the different the point cloud densities depending on the use of the building and the area of the roof.
Figure 11. F-score (%) for the different the point cloud densities depending on the use of the building and the area of the roof.
Remotesensing 12 03726 g011
Figure 12. Solar climate zones according to the Spanish Technical Construction Code.
Figure 12. Solar climate zones according to the Spanish Technical Construction Code.
Remotesensing 12 03726 g012
Figure 13. Mean relative error (%) in the rooftop area calculated for the different the point cloud densities depending on the use of the building and the area of the roof.
Figure 13. Mean relative error (%) in the rooftop area calculated for the different the point cloud densities depending on the use of the building and the area of the roof.
Remotesensing 12 03726 g013
Figure 14. Average daily PV energy production per square meter loss (Wh/m2) for industrial buildings with an area smaller than 200 m2: (a) flat roof, (b) gable roof.
Figure 14. Average daily PV energy production per square meter loss (Wh/m2) for industrial buildings with an area smaller than 200 m2: (a) flat roof, (b) gable roof.
Remotesensing 12 03726 g014
Figure 15. Average daily PV energy production per square meter loss (Wh/m2) for industrial buildings with an area bigger than 200 m2: (a) flat roof, (b) gable roof.
Figure 15. Average daily PV energy production per square meter loss (Wh/m2) for industrial buildings with an area bigger than 200 m2: (a) flat roof, (b) gable roof.
Remotesensing 12 03726 g015
Figure 16. Average daily PV energy production per square meter loss (Wh/m2) for residential buildings with an area smaller than 200 m2: (a) gable roof, (b) hipped roof.
Figure 16. Average daily PV energy production per square meter loss (Wh/m2) for residential buildings with an area smaller than 200 m2: (a) gable roof, (b) hipped roof.
Remotesensing 12 03726 g016
Figure 17. Average daily PV energy production per square meter loss (Wh/m2) for residential buildings with a surface bigger than 200 m2: (a) gable roof, (b) hipped roof.
Figure 17. Average daily PV energy production per square meter loss (Wh/m2) for residential buildings with a surface bigger than 200 m2: (a) gable roof, (b) hipped roof.
Remotesensing 12 03726 g017
Table 1. Main characteristics of data derived from the National Plan for Aerial Orthophotography (PNOA) Project. Data offered by the Spanish National Geographic Institute on their web page.
Table 1. Main characteristics of data derived from the National Plan for Aerial Orthophotography (PNOA) Project. Data offered by the Spanish National Geographic Institute on their web page.
ProductFlight GSD 1 (cm)GSD Orthophoto (cm)Planimetric Accuracy in Orthophoto (m)
PNOA 50 cm4550RMSExy 2 ≤ 1.00
PNOA 25 cm2225RMSExy ≤ 0.50
1 GSD stands for Ground Sample Distance, the distance between pixel centers measured on the ground. 2 RMSExy stands from the planimetric Root Mean Square Error (in the xy plane, the plane of the terrain).
Table 2. Technical characteristics of the point clouds resulting from PNOA-LiDAR first and second coverages. Data offered by the Spanish National Geographic Institute through their web page.
Table 2. Technical characteristics of the point clouds resulting from PNOA-LiDAR first and second coverages. Data offered by the Spanish National Geographic Institute through their web page.
CoverageDensity (Points/m2)Elevation Accuracy (m)Elevation Precision (m) Estimated Planimetric Accuracy (m)
First0.5 RMSEz ≤ 0.4 RMSEz ≤ 0.2–0.4 ≤ 0.3
Second1, 2 and 14 RMSEz ≤ 0.2 RMSEz ≤ 0.15–0.2≤ 0.3
Table 3. Buildings selected for the different cases.
Table 3. Buildings selected for the different cases.
CaseIndustrial BuildingResidential Building
Case 13525
Case 24234
Case 34336
Table 4. Main features of the first coverage LiDAR data.
Table 4. Main features of the first coverage LiDAR data.
CaseFlight DateLaser ScannerDensity (Points/m2) RMSE xy (m)RMSE z (m)
Case 12010Leica ALS500.5 0.30 0.40
Case 22010Leica ALS500.5 0.30 0.40
Case 32012Leica ALS600.5 0.30 0.20
Table 5. Main features of the second coverage LiDAR data.
Table 5. Main features of the second coverage LiDAR data.
CaseFlight DateLaser ScannerDensity (Points/m2)RMSE xy (m)RMSE z (m)
Case 12017Leica ALS8010.200.15
Case 22016Leica ALS8020.300.20
Case 32017Leica SPL100140.200.15
Table 6. Average RMSE (m2) per point cloud density for industrial buildings.
Table 6. Average RMSE (m2) per point cloud density for industrial buildings.
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Surface < 200 m22615205
Surface > 200 m268364713
Table 7. Average RMSE (m2) per point cloud density for residential buildings.
Table 7. Average RMSE (m2) per point cloud density for residential buildings.
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Surface < 200 m23019217
Surface > 200 m288386220
Table 8. Mean computation time (s) per point cloud density for industrial buildings.
Table 8. Mean computation time (s) per point cloud density for industrial buildings.
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Number of points11262463687648,399
Mean computation time481390
Table 9. Mean computation time (s) per point cloud density for residential buildings.
Table 9. Mean computation time (s) per point cloud density for residential buildings.
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Number of points10482660364146,863
Mean computation time37674
Table 10. Annual average daily global solar radiation (H).
Table 10. Annual average daily global solar radiation (H).
Solar Climate ZonesSolar Radiation (kWh/m2)
IH < 3.8
II3.8 ≤ H < 4.2
III4.2 ≤ H < 4.6
IV4.6 ≤ H < 5.0
VH ≥ 5.0
Table 11. Average altitude of the different study cases in the calculation of solar energy.
Table 11. Average altitude of the different study cases in the calculation of solar energy.
Solar Climate ZonesCityAverage Altitude (m)
IA Coruña22
IIPamplona450
IIIZamora652
IVCiudad Real628
VAlmería27
Table 12. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a flat roof of 100 m2.
Table 12. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a flat roof of 100 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 119 11104
Zone 22012114
Zone 32213124
Zone 42314125
Zone 526 15145
Table 13. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a flat roof of 400 m2.
Table 13. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a flat roof of 400 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 12915226
Zone 23116237
Zone 33418257
Zone 43518268
Zone 54021299
Table 14. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a gable roof of 100 m2.
Table 14. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a gable roof of 100 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 19551
Zone 29551
Zone 310661
Zone 411662
Zone 512772
Table 15. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a gable roof of 400 m2.
Table 15. Average daily electrical energy loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: industrial buildings with a gable roof of 400 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 1148103
Zone 2158113
Zone 3169123
Zone 4179123
Zone 51910143
Table 16. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a gable roof of 100 m2.
Table 16. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a gable roof of 100 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 18551
Zone 28551
Zone 39661
Zone 49662
Zone 510772
Table 17. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a gable roof of 400 m2.
Table 17. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a gable roof of 400 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 1199134
Zone 2209134
Zone 32210154
Zone 42311155
Zone 52612175
Table 18. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a hipped roof of 100 m2.
Table 18. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a hipped roof of 100 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zone 15441
Zone 25441
Zone 36441
Zone 46552
Zone 57552
Table 19. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a hipped roof of 400 m2.
Table 19. Average daily PV energy production loss (kWh) due to the error in the estimation of the rooftop area for different point cloud densities: residential building with a hipped roof of 400 m2.
Solar Climate ZonesRMSE (kWh)
0.5 Point/m21 Point/m22 Points/m214 Points/m2
Zona 113693
Zona 213793
Zona 3157103
Zona 4158113
Zona 5179123
Table 20. The results of quality analysis of building outline extraction for different point cloud densities (1 cm, 2.5 cm, 5 cm, 10 cm, 20 cm) for a direct approach.
Table 20. The results of quality analysis of building outline extraction for different point cloud densities (1 cm, 2.5 cm, 5 cm, 10 cm, 20 cm) for a direct approach.
Point Density (Points/m2)
10,000 Points/m21600 Points/m2400 Points/m2100 Points/m225 Points/m2
Precision (%)97.9497.9597.9497.7297.31
Recall (%)99.3099.2599.2999.5299.47
F-score (%)97.2697.2397.2997.2696.80
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sánchez-Aparicio, M.; Del Pozo, S.; Martín-Jiménez, J.A.; González-González, E.; Andrés-Anaya, P.; Lagüela, S. Influence of LiDAR Point Cloud Density in the Geometric Characterization of Rooftops for Solar Photovoltaic Studies in Cities. Remote Sens. 2020, 12, 3726. https://doi.org/10.3390/rs12223726

AMA Style

Sánchez-Aparicio M, Del Pozo S, Martín-Jiménez JA, González-González E, Andrés-Anaya P, Lagüela S. Influence of LiDAR Point Cloud Density in the Geometric Characterization of Rooftops for Solar Photovoltaic Studies in Cities. Remote Sensing. 2020; 12(22):3726. https://doi.org/10.3390/rs12223726

Chicago/Turabian Style

Sánchez-Aparicio, María, Susana Del Pozo, Jose Antonio Martín-Jiménez, Enrique González-González, Paula Andrés-Anaya, and Susana Lagüela. 2020. "Influence of LiDAR Point Cloud Density in the Geometric Characterization of Rooftops for Solar Photovoltaic Studies in Cities" Remote Sensing 12, no. 22: 3726. https://doi.org/10.3390/rs12223726

APA Style

Sánchez-Aparicio, M., Del Pozo, S., Martín-Jiménez, J. A., González-González, E., Andrés-Anaya, P., & Lagüela, S. (2020). Influence of LiDAR Point Cloud Density in the Geometric Characterization of Rooftops for Solar Photovoltaic Studies in Cities. Remote Sensing, 12(22), 3726. https://doi.org/10.3390/rs12223726

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop