Next Article in Journal
Bottom-Up Proteomic Analysis of Polypeptide Venom Components of the Giant Ant Dinoponera Quadriceps
Next Article in Special Issue
Immunohistochemical Review of Leydig Cell Lesions in Ochratoxin A-Treated Fischer Rats and Controls
Previous Article in Journal
Ostreopsis cf. ovata Bloom in Currais, Brazil: Phylogeny, Toxin Profile and Contamination of Mussels and Marine Plastic Litter
Previous Article in Special Issue
Ochratoxin A-Induced Hepatotoxicity through Phase I and Phase II Reactions Regulated by AhR in Liver Cells
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Label-Free Fluorescent Aptasensor for Ochratoxin—A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin

1
College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China
2
Institute for Agro-food Standards and Testing Technology, Shanghai Key Laboratory of Protected Horticultural Technology, Laboratory of Quality and Safety Risk Assessment for Agro-products (Shanghai), Ministry of Agriculture, Shanghai Academy of Agricultural Sciences, Shanghai 201403, China
*
Authors to whom correspondence should be addressed.
Toxins 2019, 11(8), 447; https://doi.org/10.3390/toxins11080447
Submission received: 25 June 2019 / Revised: 15 July 2019 / Accepted: 26 July 2019 / Published: 28 July 2019
(This article belongs to the Special Issue Ochratoxin in Food Safety and Public Health)

Abstract

:
With the widespread contamination of ochratoxin A (OTA), it is of significant importance for detecting OTA in foods and traditional Chinese medicine (TCM). In this study, a novel label-free fluorescent aptasensor utilizing the interaction between OTA-triggered antiparallel G-quadruplex and (N-methyl-4-pyridy) porphyrin (TMPyP) for the rapid and sensitive determination of OTA was established. The fluorescence of CdTe quantum dots (QDs) could be quenched by TMPyP. In the presence of analyte (OTA), the aptamer could recognize OTA and transform from a random coil to the antiparallel G-quadruplex. The interaction between G-quadruplex and TMPyP could release CdTe QDs from TMPyP, and thus recover the fluorescence of CdTe QDs. Under optimized conditions, the detection limit of the designed aptasensor was 0.16 ng mL−1, with a linear range of 0.2 to 20 ng mL−1. Furthermore, this aptasensor showed high selectivity toward OTA against other structural analogs and other mycotoxins, and was successfully applied in Astragalus membranaceus samples. The presented aptasensor for OTA detection could be a promising tool for the field monitoring of food and TCM.
Key Contribution: A label-free fluorescent aptasensor for the sensitive determination of ochratoxin A utilizing the interaction between OTA-triggered G-quadruplex and TMPyP is reported.

Graphical Abstract

1. Introduction

Ochratoxin A (OTA) is a toxic metabolite derived mainly from Aspergillus ochraceus and Penicillium verrucosum [1,2], which are widely present as contaminants in a variety of products, including wines, corn, coffee, milk, and traditional Chinese medicine (TCM) [3,4]. OTA is found to cause severe toxic effects, such as those that are teratogenic, embryotoxic, genotoxic, neurotoxic, immunosuppressive, carcinogenic, and nephrotoxic to humans [5]. Since OTA presents a serious threat to the health and safety of humans, it was classified as being possibly carcinogenic to humans (Group 2B) by the International Agency for Research on Cancer (IARC) [6]. Astragalus membranaceus, as a major medicinal herb, has been broadly applied in clinical settings for treating diseases and promoting health [7]. It is especially important to ensure the safety of TCM, which has been frequently contaminated by mycotoxins during growth, collection, transportation, and storage [8,9].
Current analysis of OTA is conducted by various methods, including high-performance liquid chromatography (HPLC) [10], HPLC tandem mass spectrometry (HPLC-MS/MS) [11], and the enzyme-linked immunosorbent assay (ELISA) [12]. Although these methods have both high accuracy and sensitivity, they still have some shortcomings, such as being time consuming, and requiring tedious sample pretreatment and expensive instruments [13]. Biosensors are considered to be promising devices for the determination of chemical compounds such as toxins [14]. Among biosensors, the methods based on optical aptasensors are impressive [15]. Tian et al. have put forward a nanozyme-based cascade colorimetric aptasensor for the amplified detection of OTA [16]. However, the aptamer must be modified with fluorophores in these methods, while the manipulation of DNA modification is expensive and time consuming, which still urgently needs to be improved [17]. Therefore, it would be highly desirable to establish a rapid, convenient, low-cost, and sensitive method for OTA detection.
As an emerging type of fluorescent probe, the excellent optical properties of quantum dots (QDs) have meant that they have received tremendous attention in the fields of optical sensors, biosensing, biomedical analyses, and mycotoxin detection [18,19,20]. In the recent mycotoxin detection mode, the fluorescence change of quantum dots (QDs) was shown to be unidirectional, and the interaction with the analyte was evaluated by either quenching or enhancement [21]. However, this unidirectional mode may be affected by environmental stimuli and thus cause “false positive” results [22]. Porphyrins have been intensively reported as sensing materials in optical sensors [23]. They possess many attractive properties, including high chemical and thermal stability, high molar absorptivity, and a large extinction coefficient in the visible light region [24]. These optical advantages make porphyrin an ideal choice as the receptor in the photo-induced electron transfer (PET)-based “turn off” process. Recently, significant efforts have been made to apply such PET-based sensing platforms for the sensitive determination of various analytes such as DNA and metal ions [25,26]. However, as far as we know, no method has been reported for the sensitive detection of OTA utilizing (N-methyl-4-pyridy) porphyrin (TMPyP). Therefore, the unique aspect of this work is that we first report a label-free aptasensor detection method for OTA utilizing the interaction between TMPyP and OTA-triggered antiparallel G-quadruplex. The reported label-free fluorescent aptasensor has been successfully applied to the analysis of OTA in Astragalus membranaceus. It is expected that the aptasensor has tremendous potential for detecting OTA in TCM samples.

2. Results and Discussion

2.1. Design Strategy for OTA Detection

Scheme 1 shows the design strategy of a label-free fluorescent aptasensor for OTA detection. The fluorescence intensity of CdTe QDs was effectively quenched by TMPyP through PET [27]. In the presence of the analyte (OTA), the aptamers recognized the target and were induced to conformationally transform into the antiparallel G-quadruplex structure [28]. As TMPyP is a distinguished G-quadruplex ligand [29], it could interact with G-quadruplexes by outside groove binding and terminal π–π stacking interactions [30]. Since TMPyP occupied by G-quadruplexes was buried inside the structures, the interaction force between the CdTe QDs and the TMPyP became very weak, resulting in a significantly enhancement in the fluorescence intensity. Therefore, this restoration of fluorescence was interpreted as an analytical signal to evaluate the amount of OTA.
To further validate the feasibility of the established method, corresponding control experiments were carried out. In the absence of TMPyP, the fluorescence intensity of the CdTe QDs/aptamer was highly overlapping with or without OTA (Figure 1A). However, when TMPyP was included in the determination steps, the sample containing 20 ng mL−1 of OTA showed significantly higher fluorescence intensity than the blank sample (Figure 1B). This phenomenon proved that the fluorescence recovery of CdTe QDs was indeed caused by the combination of the TMPyP and G-quadruplex.

2.2. Characterization of G-Quadruplex Formation

To verify the formation of the antiparallel G-quadruplex, the circular dichroism (CD) spectrum was employed. Before the introduction of OTA, the aptamer presented the characteristic of random-coil DNA (a in Figure 2). After the addition of OTA (5 μg mL−1), the CD spectrum exhibited an evident enhancement at about 265 nm for the negative band and at 290 nm for the positive band (b in Figure 2). This signal change in the CD spectra could be due to the interaction of OTA with the aptamer, which is a notable characteristic of antiparallel G-quadruplex formation [31].

2.3. Optimization of the Concentration of Porphyrin and Incubation Time

To achieve high sensitivity for the label-free aptasensor, we optimized the concentration of TMPyP and incubation time. A higher concentration of TMPyP can largely quench the fluorescence intensity of CdTe QDs, and at a sufficient concentration of TMPyP, the fluorescence intensity of CdTe QDs can be completely quenched. However, an excess of quencher will inhibit the fluorescence recovery of CdTe QDs after the addition of an OTA aptamer, which is possibly due to the interaction between the G-quadruplex and “free” TMPyP. On the other hand, TMPyP deficiency does not effectively quench the fluorescence intensity of CdTe QDs, which may affect the detection of OTA. The value, I, was introduced to describe relative fluorescence recovery rates:
I = (F2 − F1)/F0
where F0 and F1 are the fluorescence intensity of CdTe QDs with and without TMPyP, respectively, and F2 represents the fluorescence intensity in the presence of the OTA aptamer. As shown in Figure 3, excessive or insufficient TMPyP is not advantageous to the fluorescence recovery of CdTe QDs. When the concentration of TMPyP was 0.175 μmol L−1, the fluorescence of QDs was quenched to 39.67%, and recovered to 86.90% of the original fluorescence of CdTe QDs after being exposed to OTA (20 ng mL−1). Based on this result, the concentration of TMPyP was fixed as 0.175 μmol L−1. As shown in Figure 3C, the incubation time was optimized, the fluorescence recovery reaches a plateau at 5 min. Therefore, the five minutes was chosen as the incubation time.

2.4. Quantitative Analysis of OTA

Under the optimized conditions, we investigated the fluorescence spectrum after the addition of OTA. As shown in Figure 4A, a gradual increase in the fluorescence intensity at 555 nm was observed following an increase in OTA concentration from 0.2 to 20 ng mL−1. Figure 4B shows the linear relationship between the fluorescence intensity and the concentration of OTA (0.2 to 20 ng mL−1) (R2 = 0.994). The limit of detection (LOD) for OTA was calculated to be 0.16 ng mL−1 by three times the standard deviation of the background (3σ). As shown in Table 1, the linear range and LOD of the fluorescent aptasensor were compared with the current methods, and it was concluded that the current fluorescent aptasensor for the detection and quantification of OTA has a satisfactory linear dynamic range and detection limit. The repeatability was obtained by measuring the fluorescent intensity of the same sample (15 ng mL−1, OTA) six times, in which the coefficient of variation (CV) was 2% and the reproducibility was measured in different days, with a CV less than 2%, showing the good repeatability and reproducibility of this method.

2.5. Specificity of the OTA Aptasensor

To confirm that the fluorescence intensity signal was caused by the unique recognition between aptamers and OTA, it was critical to test the specificity of the fluorescent aptasensor against other structure analogs of OTA (ochratoxin B (OTB) and ochratoxin C (OTC)) and other mycotoxins (zearalenone (ZEA) and HT-2 toxin (HT-2)). The concentration of OTA was 15 ng mL−1, whereas the concentration of the other toxins was 25 ng mL−1 in the specificity experiment. As shown in Figure 5, the fluorescence intensity displayed no evident change in the presence of HT-2, ZEN, OTB, and OTC. Considering that a sample may contain multiple mycotoxins, we also investigated the recognition performance of OTA in the presence of other mycotoxins. The signal responses did not change significantly when other mycotoxins were introduced to the aptasensor. These results clearly demonstrated that this fluorescent aptasensor for the determination of OTA exhibited an excellent specificity against different kinds of mycotoxins. The high specificity of the reported sensing platform was mainly due to the high affinity of the OTA aptamer.

2.6. Detection of OTA in Real Samples

To evaluate the practicability and reliability of the presented aptasensor, we challenged our aptasensor with Astragalus membranaceus samples. As expressed in Table 2, the recoveries of OTA-spiked samples ranged from 98.9% to 102.2%, suggesting that this label-free aptasensor can be applied for the detection of OTA analysis in Astragalus membranaceus. However, CdTe QDs and the TMPyP based sensing system have limitations in detecting OTA in complex environmental samples, which may frequently contain nickel ions, Hg (II) ions, and pesticides. These coexistences can quench the fluorescence intensity of CdTe QDs and then affect the sensing ability of OTA detection.

3. Conclusions

In summary, a label-free fluorescent aptasensor based on the TMPyP/G-quadruplex for OTA detection was reported. Benefiting from a high specificity and affinity between the OTA and aptamer, the aptamer was switched into G-quadruplex, which could combine with TMPyP. This detection strategy avoids the laborious and expensive process of DNA modification. The designed sensing platform exhibits a superior range of detection and potential selectivity. The linear dynamic range and detection limits were 0.2 to 20 ng mL−1 and 0.16 ng mL−1, respectively. The application of the aptasensor has been verified in Astragalus membranaceus, with relative recovery values of 98.9% to 102.2%. This work provides a brand-new strategy for the OTA aptasensor based on the G-quadruplex-aptamer and TMPyP, and has great potential for applications for OTA analysis in food and TCM contamination detection.

4. Experimental

4.1. Materials and Reagents

Sodium tellurite (Na2TeO3), sodium borohydride (NaBH4), and cadmium chloride (CdCl2) were obtained from Aladdin Chemistry Co., Ltd. (Shanghai, China). Potassium chloride (KCl), magnesium chloride (MgCl2), calcium chloride (CaCl2), and acetonitrile were bought from Tianjin Yongda Chemical Reagent Co., Ltd. (Tianjin, China). N-acetyl-L-cysteine (NAC) was bought from Yuanye Biological Technology Co., Ltd. (Shanghai, China). TMPyP was chemically synthesized by J & K Scientific Ltd. (Shanghai, China). Hydrochloric acid (HCL) was purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Tris [Tris-(hydroxy-methyl) aminomethane] was purchased from Shanghai Lingfeng Chemical Reagent Co., Ltd. (Jiangsu, China). OTA, OTB, OTC, ZEA, and HT-2 were purchased from Romer Labs Inc. (St. Louis, MO, USA) and dissolved in acetonitrile to prepare 10 μg mL−1 of stock solutions. The stock solutions were stored in the dark at −20 °C. The OTA aptamers (5′-GAT CGG GTG TGG GTG GCG TAA AGG GAG CAT CGG ACA-3′) [36] were synthesized and purified by Sangon Biotechnology Co. Ltd. (Shanghai, China). A binding buffer (10 mM of Tris-HCl, pH = 8.0, 120 mM of NaCl, 20 mM of CaCl2, and 20 mM of MgCl2) was prepared for the binding reaction between OTA and the aptamer. Astragalus membranaceus samples were purchased from Jiangxi Yaodutang Chinese Herbal Pieces Co., Ltd. (zhangshu, China).

4.2. Instrumentation

CD spectra were measured on a JASCO J-1500 spectropolarimeter (Tokyo, Japan) in 10 mM of binding buffer. The fluorescence spectra were acquired by a Hitachi F-2700 fluorescence spectrophotometer (Tokyo, Japan). The experimental parameters were set as follows: emission wavelength (λem), 490 to 630 nm; excitation wavelength (λex), 360 nm; emission slit, 10 nm; excitation slit, 10 nm. The deionized water used throughout the study was prepared by a Milli-Q Reference water purification system (Merck Millipore, Billerica, MA, USA).

4.3. Optimization of Experimental Conditions

In order to obtain the best experimental results, the concentration of TMPyP and incubation time were both optimized. The concentration range of TMPyP was 0.1 μmol L−1, 0.125 μmol L−1, 0.15 μmol L−1, 0.175 μmol L−1, and 0.2 μmol L−1. The fluorescence of CdTe QDs/TMPyP was performed as follows. Different concentrations of TMPyP were mixed with 80 μL of CdTe QDs (4.2 × 10−9 mol L−1) at room temperature. The fluorescence of the CdTe QDs/TMPyP/OTA aptamer was conducted as follows: 50 μL of OTA-aptamer (20 ng mL−1), different concentrations of TMPyP, and 80 μL of CdTe QDs (4.2 × 10−9 mol L−1). The incubation times were 1 min, 3 min, 5 min, 8 min, and 10 min. (CdTe: 4.2 × 10−9 mol L−1; TMPyP: 0.175 μmol L−1; OTA: 15 ng mL−1). The emission spectrum of the sample was measured, and each sample was measured three times.

4.4. Measurement of Aptamer Conformation with CD

The aptamer conformation was measured by a CD spectropolarimeter. The DNA aptamer (5 μM) and DNA aptamer (5 μM) with OTA (5 μg mL−1) were placed in an optical chamber (1-cm path length, 400 μL volume), which was deoxygenated with dry purified nitrogen (99.99%) prior to analysis and also insulated by a nitrogen atmosphere. The CD spectrum was run in triplicate with a 200-nm/min scan speed, 1-nm bandwidth, and 1-s time constant. The data were measured in a range of 230 to 340 nm at 0.1-nm intervals. The buffer solution was used as a blank to correct the background.

4.5. Determination of OTA by Fluorescence Aptasensors

For the quantitative determination of OTA, different concentrations of OTA were mixed with 250-nM aptamers in binding buffer and heated at 95 °C for 5 min, and were then cooled down to room temperature for upcoming experiments. After that, samples containing 175 μL of TMPyP (1.75 × 10−7 mol L−1), 80 μL of CdTe QDs (4.2 × 10−9 mol L−1), and 50 μL of OTA aptamer were made up to 1 mL. After equilibrating at room temperature for 5 min, the fluorescence emission spectra were measured at a wavelength range from 490 to 630 nm.

4.6. Specificity Assay

To verify the specificity of the aptasensor, HT-2, ZEA, OTB, and OTC were used as controls. Firstly, OTA (15 ng mL−1), HT-2 (25 ng mL−1), ZEA (25 ng mL−1), OTB (25 ng mL−1), and OTC (25 ng mL−1) were separately added into 250 nM of aptamer in binding buffer, and then heated at 95 °C for 5 min before being gradually cooled down to room temperature. Following this, samples containing 175 μL of TMPyP (1.75 × 10−7 mol L−1), 80 μL of CdTe QDs (4.2 × 10−9 mol L−1), and 50 μL of mycotoxins aptamer were made up to 1 mL. Multiple mycotoxins, including 175 μL of TMPyP, 80 μL of CdTe QDs, and 50 μL of OTA-aptamer, as well as other mycotoxins, were made up to 1 mL. After 5 min, the fluorescence intensity was measured.

4.7. Determination of OTA in Astragalus membranaceus

To verify the feasibility of this aptasensor, Astragalus membranaceus was chosen and finely grounded with a disintegrator. Then, samples were passed through a 0.22-mm aperture test sieve. A total of 1 g of the samples was spiked into different concentrations of OTA, and the mixtures were introduced into a 5-mL extracting solution (acetonitrile/water, 80:20, v/v). The samples were ultrasonicated for 10 min and then centrifuged at 4000 rpm for 10 min. The supernatant underwent a fivefold dilution with deionized water to minimize the matrix effect [37]. Additionally, subsequent manipulation was conducted according to the reported method.

Author Contributions

Conceptualization, L.L; Data curation, Z.I.T., K.J., Q.H. and J.Z.; Formal analysis, Z.I.T.; Funding acquisition, Y.W.; Investigation, L.L. and Z.I.T.; Methodology, L.L.; Resources, Q.H. and Z.H.; Supervision, Y.W.; Writing—original draft, L.L. and K.J.; Writing—review & editing, Y.W. and Z.H.

Funding

This work was funded by National Major Scientific and Technological Special Project for “Significant New Drugs Development” (No. 2018ZX09201010, 2013ZX09402203).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Van Der Merwe, K.J.; Steyn, P.S.; Fourie, L.; Scott, D.B.; Theron, J.J. Ochratoxin A, a Toxic Metabolite produced by Aspergillus ochraceus Wilh. Nature 1965, 205, 1112–1113. [Google Scholar] [CrossRef] [PubMed]
  2. Malir, F.; Ostry, V.; Pfohl-Leszkowicz, A.; Malir, J.; Toman, J. Ochratoxin A: 50 years of research. Toxins 2016, 8, 191. [Google Scholar] [CrossRef] [PubMed]
  3. Jodra, A.; Hervás, M.; López, M.Á.; Escarpa, A. Disposable electrochemical magneto immunosensor for simultaneous simplified calibration and determination of Ochratoxin A in coffee samples. Sens. Actuators B Chem. 2015, 221, 777–783. [Google Scholar] [CrossRef]
  4. Yang, Y.; Wen, J.; Kong, W.; Liu, Q.; Luo, H.; Wang, J.; Yang, M. Simultaneous determination of four aflatoxins and ochratoxin A in ginger after inoculation with fungi by ultra-fast liquid chromatography–tandem mass spectrometry. J. Sci. Food Agric. 2016, 96, 4160–4167. [Google Scholar] [CrossRef] [PubMed]
  5. Erceg, S.; Mateo, E.M.; Zipancic, I.; Jiménez, F.R.; Aragó, M.P.; Jiménez, M.; Soria, J.M.; Garcia-Esparza, M. Ángeles Assessment of Toxic Effects of Ochratoxin A in Human Embryonic Stem Cells. Toxins 2019, 11, 217. [Google Scholar] [CrossRef]
  6. Al-Jaal, B.A.; Jaganjac, M.; Barcaru, A.; Horvatovich, P.; Latiff, A. Aflatoxin, fumonisin, ochratoxin, zearalenone and deoxynivalenol biomarkers in human biological fluids: A systematic literature review, 2001–2018. Food Chem. Toxicol. 2019, 129, 211–228. [Google Scholar] [CrossRef] [PubMed]
  7. Auyeung, K.K.; Han, Q.-B.; Ko, J.K. Astragalus membranaceus: A Review of its Protection Against Inflammation and Gastrointestinal Cancers. Am. J. Chin. Med. 2016, 44, 1–22. [Google Scholar] [CrossRef] [PubMed]
  8. Toman, J.; Ostrý, V.; Grosse, Y.; Roubal, T.; Malíř, F. Occurrence of ochratoxin A in Astragalus propinquus root and its transfer to decoction. Mycotoxin Res. 2018, 34, 223–227. [Google Scholar] [CrossRef] [PubMed]
  9. Zhou, W.; Kong, W.; Dou, X.; Zhao, M.; Ouyang, Z.; Yang, M. An aptamer based lateral flow strip for on-site rapid detection of ochratoxin A in Astragalus membranaceus. J. Chromatogr. B 2016, 1022, 102–108. [Google Scholar] [CrossRef]
  10. Luan, C.L.; Wang, L.; Chen, F.F.; Wang, S.; Zhao, L.; Shao, L.H. Determination of ochratoxin A in pig muscle using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography. Food Anal. Methods 2016, 9, 1490–1494. [Google Scholar] [CrossRef]
  11. Andrade, M.A.; Lanças, F.M. Determination of Ochratoxin A in wine by packed in-tube solid phase microextraction followed by high performance liquid chromatography coupled to tandem mass spectrometry. J. Chromatogr. A 2017, 1493, 41–48. [Google Scholar] [CrossRef]
  12. Pei, K.; Xiong, Y.; Xu, B.; Wu, K.; Li, X.; Jiang, H.; Xiong, Y. Colorimetric ELISA for ochratoxin A detection based on the urease-induced metallization of gold nanoflowers. Sens. Actuators B Chem. 2018, 262, 102–109. [Google Scholar] [CrossRef]
  13. Han, Z.; Jiang, K.; Fan, Z.; Di Mavungu, J.D.; Dong, M.; Guo, W.; Fan, K.; Campbell, K.; Zhao, Z.; Wu, Y. Multi-walled carbon nanotubes-based magnetic solid-phase extraction for the determination of zearalenone and its derivatives in maize by ultra-high performance liquid chromatography-tandem mass spectrometry. Food Control 2017, 79, 177–184. [Google Scholar] [CrossRef]
  14. Cheng, A.K.; Sen, D.; Yu, H.-Z. Design and testing of aptamer-based electrochemical biosensors for proteins and small molecules. Bioelectrochemistry 2009, 77, 1–12. [Google Scholar] [CrossRef]
  15. Feng, C.; Dai, S.; Wang, L. Optical aptasensors for quantitative detection of small biomolecules: A review. Biosens. Bioelectron. 2014, 59, 64–74. [Google Scholar] [CrossRef]
  16. Tian, F.; Zhou, J.; Jiao, B.; He, Y. A nanozyme-based cascade colorimetric aptasensor for amplified detection of ochratoxin A. Nanoscale 2019, 11, 9547–9555. [Google Scholar] [CrossRef]
  17. Wu, K.; Ma, C.; Zhao, H.; He, H.; Chen, H. Label-Free G-Quadruplex Aptamer Fluorescence Assay for Ochratoxin A Using a Thioflavin T Probe. Toxins 2018, 10, 198. [Google Scholar] [CrossRef]
  18. Meng, C.; Xiao, Y.; Wang, P.; Zhang, L.; Liu, Y.; Tong, L. Quantum-Dot-Doped Polymer Nanofibers for Optical Sensing. Adv. Mater. 2011, 23, 3770–3774. [Google Scholar] [CrossRef]
  19. Liu, Y.; Dong, P.; Jiang, Q.; Wang, F.; Pang, D.-W.; Liu, X. Assembly-enhanced fluorescence from metal nanoclusters and quantum dots for highly sensitive biosensing. Sens. Actuators B Chem. 2019, 279, 334–341. [Google Scholar] [CrossRef]
  20. Goftman, V.V.; Aubert, T.; Ginste, D.V.; Van Deun, R.; Beloglazova, N.V.; Hens, Z.; De Saeger, S.; Goryacheva, I.Y. Synthesis, modification, bioconjugation of silica coated fluorescent quantum dots and their application for mycotoxin detection. Biosens. Bioelectron. 2016, 79, 476–481. [Google Scholar] [CrossRef]
  21. Ebrahim, S.; Labeb, M.; Abdel-Fattah, T.; Soliman, M. CdTe quantum dots capped with different stabilizing agents for sensing of ochratoxin A. J. Lumin. 2017, 182, 154–159. [Google Scholar] [CrossRef]
  22. Zhang, B.; Lu, Y.; Yang, C.; Guo, Q.; Nie, G. Simple “signal-on” photoelectrochemical aptasensor for ultrasensitive detecting AFB1 based on electrochemically reduced graphene oxide/poly(5-formylindole)/Au nanocomposites. Biosens. Bioelectron. 2019, 134, 42–48. [Google Scholar] [CrossRef]
  23. Biesaga, M. Porphyrins in analytical chemistry. A review. Talanta 2000, 51, 209–224. [Google Scholar] [CrossRef]
  24. Zhang, M.; Fu, L.; Ye, J.; Humphrey, M.G.; Liu, H.; Yan, B.; Zhang, L.; Shao, J.; Zhang, C. Covalent-linked porphyrin/single-walled carbon nanotube nanohybrids: Synthesis and influence of porphyrin substituents on nonlinear optical performance. Carbon 2017, 124, 618–629. [Google Scholar] [CrossRef]
  25. Fan, Y.; Yu, M.; Xu, Y.; Wang, Q.; Hu, Y.; Fu, H.-Y.; She, Y.-B. Nanoporphyrin/CdTe quantum dots: A robust tool for effective differentiation among DNA structures. Sens. Actuators B Chem. 2019, 281, 623–633. [Google Scholar] [CrossRef]
  26. Frasco, M.F.; Vamvakaki, V.; Chaniotakis, N. Porphyrin decorated CdSe quantum dots for direct fluorescent sensing of metal ions. J. Nanopart. Res. 2010, 12, 1449–1458. [Google Scholar] [CrossRef]
  27. Jhonsi, M.A.; Renganathan, R. Investigations on the photoinduced interaction of water soluble thioglycolic acid (TGA) capped CdTe quantum dots with certain porphyrins. J. Colloid Interface Sci. 2010, 344, 596–602. [Google Scholar] [CrossRef]
  28. Lv, L.; Li, D.; Liu, R.; Cui, C.; Guo, Z. Label-free aptasensor for ochratoxin A detection using SYBR Gold as a probe. Sens. Actuators B Chem. 2017, 246, 647–652. [Google Scholar] [CrossRef]
  29. Wei, C.; Jia, G.; Zhou, J.; Han, G.; Li, C. Evidence for the binding mode of porphyrins to G-quadruplex DNA. Phys. Chem. Chem. Phys. 2009, 11, 4025–4032. [Google Scholar] [CrossRef]
  30. Wheelhouse, R.T.; Sun, D.; Han, H.; Han, F.X.; Hurley, L.H. Cationic Porphyrins as Telomerase Inhibitors: The Interaction of Tetra-(N-methyl-4-pyridyl)porphine with Quadruplex DNA. J. Am. Chem. Soc. 1998, 120, 3261–3262. [Google Scholar] [CrossRef]
  31. Lv, L.; Cui, C.; Liang, C.; Quan, W.; Wang, S.; Guo, Z. Aptamer-based single-walled carbon nanohorn sensors for ochratoxin A detection. Food Control 2016, 60, 296–301. [Google Scholar] [CrossRef]
  32. Lu, Z.; Chen, X.; Hu, W. A fluorescence aptasensor based on semiconductor quantum dots and MoS2 nanosheets for ochratoxin A detection. Sens. Actuators B Chem. 2017, 246, 61–67. [Google Scholar] [CrossRef]
  33. He, Y.; Tian, F.; Zhou, J.; Jiao, B. A fluorescent aptasensor for ochratoxin A detection based on enzymatically generated copper nanoparticles with a polythymine scaffold. Microchim. Acta 2019, 186, 199. [Google Scholar] [CrossRef]
  34. Sheng, L.; Ren, J.; Miao, Y.; Wang, J.; Wang, E. PVP-coated graphene oxide for selective determination of ochratoxin A via quenching fluorescence of free aptamer. Biosens. Bioelectron. 2011, 26, 3494–3499. [Google Scholar] [CrossRef]
  35. Guo, Z.; Ren, J.; Wang, J.; Wang, E. Single-walled carbon nanotubes based quenching of free FAM-aptamer for selective determination of ochratoxin A. Talanta 2011, 85, 2517–2521. [Google Scholar] [CrossRef]
  36. Cruz-Aguado, J.A.; Penner, G. Determination of Ochratoxin A with a DNA Aptamer. J. Agric. Food Chem. 2008, 56, 10456–10461. [Google Scholar] [CrossRef]
  37. Watanabe, E.; Yamasaki, T.; Hirakawa, Y.; Harada, A.; Iwasa, S.; Miyake, S. Organic solvent-free immunoassay for quantitative detection of neonicotinoid acetamiprid residues in agricultural products. Anal. Methods 2018, 10, 3162–3169. [Google Scholar] [CrossRef]
Scheme 1. Schematic description of the fluorescent aptasensor for ochratoxin A (OTA) detection.
Scheme 1. Schematic description of the fluorescent aptasensor for ochratoxin A (OTA) detection.
Toxins 11 00447 sch001
Figure 1. The fluorescence emission spectra of the CdTe quantum dots (QDs)/aptamer mixture with or without 20 ng mL−1 of OTA (A), and the fluorescence emission spectra of the CdTe QDs/aptamer/ (N-methyl-4-pyridy) porphyrin (TMPyP) mixture with or without 20 ng mL−1 OTA (B).
Figure 1. The fluorescence emission spectra of the CdTe quantum dots (QDs)/aptamer mixture with or without 20 ng mL−1 of OTA (A), and the fluorescence emission spectra of the CdTe QDs/aptamer/ (N-methyl-4-pyridy) porphyrin (TMPyP) mixture with or without 20 ng mL−1 OTA (B).
Toxins 11 00447 g001
Figure 2. Circular dichroism (CD) spectra of the aptamer (5 μM) without (a) or with OTA (5 μg mL−1) (b) in 10-mM binding buffer (pH 8.0).
Figure 2. Circular dichroism (CD) spectra of the aptamer (5 μM) without (a) or with OTA (5 μg mL−1) (b) in 10-mM binding buffer (pH 8.0).
Toxins 11 00447 g002
Figure 3. (A) Fluorescence intensity histogram of CdTe QDs/TMPyP and CdTe QDs/TMPyP/OTA aptamer in the presence of 0.1 μmol L−1, 0.125 μmol L−1, 0.15 μmol L−1, 0.175 μmol L−1, and 0.2 μmol L−1 of TMPyP. (CdTe: 4.2 × 10−9 mol L−1; OTA: 20 ng mL−1). (B) The linear plot of fluorescence intensity (F2 − F1)/F0 as a function of TMPyP (n = 3). (C) Fluorescence intensity as a function of incubation time (1, 3, 5, 8, and 10 min). (CdTe: 4.2 × 10−9 mol L−1; TMPyP: 0.175 μmol L−1; OTA: 15 ng mL−1).
Figure 3. (A) Fluorescence intensity histogram of CdTe QDs/TMPyP and CdTe QDs/TMPyP/OTA aptamer in the presence of 0.1 μmol L−1, 0.125 μmol L−1, 0.15 μmol L−1, 0.175 μmol L−1, and 0.2 μmol L−1 of TMPyP. (CdTe: 4.2 × 10−9 mol L−1; OTA: 20 ng mL−1). (B) The linear plot of fluorescence intensity (F2 − F1)/F0 as a function of TMPyP (n = 3). (C) Fluorescence intensity as a function of incubation time (1, 3, 5, 8, and 10 min). (CdTe: 4.2 × 10−9 mol L−1; TMPyP: 0.175 μmol L−1; OTA: 15 ng mL−1).
Toxins 11 00447 g003
Figure 4. (A) Fluorescence spectra of the label-free aptasensor after the addition of different concentrations of OTA (0.2 ng mL−1, 1.5 ng mL−1, 2.5 ng mL−1, 5 ng mL−1, 10 ng mL−1, 15 ng mL−1, and 20 ng mL−1). (B) The linear plot of fluorescence intensity at 555 nm as a function of the OTA concentration (0.2 ng mL−1, 1.5 ng mL−1, 2.5 ng mL−1, 5 ng mL−1, 10 ng mL−1, 15 ng mL−1, and 20 ng mL−1) (n = 3).
Figure 4. (A) Fluorescence spectra of the label-free aptasensor after the addition of different concentrations of OTA (0.2 ng mL−1, 1.5 ng mL−1, 2.5 ng mL−1, 5 ng mL−1, 10 ng mL−1, 15 ng mL−1, and 20 ng mL−1). (B) The linear plot of fluorescence intensity at 555 nm as a function of the OTA concentration (0.2 ng mL−1, 1.5 ng mL−1, 2.5 ng mL−1, 5 ng mL−1, 10 ng mL−1, 15 ng mL−1, and 20 ng mL−1) (n = 3).
Toxins 11 00447 g004
Figure 5. The specificity of the aptasensor toward OTA (15 ng mL−1) in the presence of its structural analogues and other mycotoxins (25 ng mL−1) (n = 3).
Figure 5. The specificity of the aptasensor toward OTA (15 ng mL−1) in the presence of its structural analogues and other mycotoxins (25 ng mL−1) (n = 3).
Toxins 11 00447 g005
Table 1. Comparison of previously reported methods with the current study for the determination of OTA.
Table 1. Comparison of previously reported methods with the current study for the determination of OTA.
MethodLOD (ng mL−1)Linear Range (ng mL−1)Ref
Thioflavin T0.41.2–200[17]
SYBR Gold6.78–202[28]
Single-walled carbon nanohorn 78–202[31]
QDs and MoS20.10.1–1000[32]
Copper nanoparticles 0.81–100[33]
PVP-coated graphene oxide7.620–202[34]
Single-walled carbon nanotubes9.710–81[35]
QDs and TMPyP0.160.2–20This work
Table 2. Application of the aptasensor for the determination of OTA in Astragalus membranaceus samples (n = 3).
Table 2. Application of the aptasensor for the determination of OTA in Astragalus membranaceus samples (n = 3).
SamplesSpiked (ng mL−1)Detected (ng mL−1)Recovery (%)
12.502.53 ± 0.19101.3
210.009.88 ± 0.8298.9
320.0020.45 ± 0.83102.2

Share and Cite

MDPI and ACS Style

Liu, L.; Tanveer, Z.I.; Jiang, K.; Huang, Q.; Zhang, J.; Wu, Y.; Han, Z. Label-Free Fluorescent Aptasensor for Ochratoxin—A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin. Toxins 2019, 11, 447. https://doi.org/10.3390/toxins11080447

AMA Style

Liu L, Tanveer ZI, Jiang K, Huang Q, Zhang J, Wu Y, Han Z. Label-Free Fluorescent Aptasensor for Ochratoxin—A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin. Toxins. 2019; 11(8):447. https://doi.org/10.3390/toxins11080447

Chicago/Turabian Style

Liu, Li, Zafar Iqbal Tanveer, Keqiu Jiang, Qingwen Huang, Jinghui Zhang, Yongjiang Wu, and Zheng Han. 2019. "Label-Free Fluorescent Aptasensor for Ochratoxin—A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin" Toxins 11, no. 8: 447. https://doi.org/10.3390/toxins11080447

APA Style

Liu, L., Tanveer, Z. I., Jiang, K., Huang, Q., Zhang, J., Wu, Y., & Han, Z. (2019). Label-Free Fluorescent Aptasensor for Ochratoxin—A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin. Toxins, 11(8), 447. https://doi.org/10.3390/toxins11080447

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop