1. Introduction
Anti-CD20-targeted monoclonal antibodies, both unlabeled and radiolabeled, are active agents in the treatment of B-cell lymphomas [
1,
2]. The addition of radioactivity to the anti-CD20 antibody increases therapeutic efficacy over the unlabeled antibody [
3,
4]. The FDA has approved two anti-CD20 radio-immunotherapies for follicular lymphomas:
131I tositumomab plus unlabeled tositumomab (Bexxar
®, Philadelphia, PA, USA) and rituximab plus
90Y ibritumomab tiuxetan (Zevalin
®, East Windsor, NJ, USA). Their administered radioactivity doses, and quite likely their efficacy, are limited by hematopoietic toxicity, predominantly thrombocytopenia [
5].
131I rituximab has similar efficacy and dose, limiting hematopoietic toxicities [
6]. While anti-CD20 radio-immunotherapies are effective and safe, their utilization at non-myeloablative doses has been relatively limited given the availability of other therapeutic approaches and other factors, with only 44 treatments reported for Zevalin in a European therapy survey in 2015 [
7,
8]. Indeed, Bexxar is no longer commercially available, mainly due to low commercial sales.
Lymphomas, particularly follicular lymphomas, are not generally cured with conventional therapies. Consolidative
131I Bexxar radioimmunotherapy after conventional chemotherapy has recently shown very promising outcomes [
9]. Thus, there is renewed interest in the use of radioimmunotherapy and other approaches to improve outcomes of patients with lymphoma.
Using modern SPECT/CT dosimetry approaches, baseline
131I tositumomab dosimetry scans predict radiation dosimetry estimates on post-therapy scans. Dosimetry also showed increased radiation-absorbed dose (>200 cGy) to lymphomas to be significantly associated with longer progression-free survival [
10]. Thus, there is strong evidence to suggest that increasing tumor radiation-absorbed dose would enhance tumor response.
To substantially increase radiation-absorbed doses to tumors requires dose escalation with stem cell transplant support to mitigate hematopoietic toxicities.
131I tositumomab has been used at myeloablative doses guided by planar dosimetry with stem cell transplants, with encouraging results [
11,
12,
13].
The radiation dosimetry profiles differ between
131I tositumomab and
90Y ibritumomab tiuxetan, with a substantially higher radiation-absorbed dose delivered to the liver by
90Y ibritumomab tiuxetan relative to
131I tositumomab. This is likely because radiometals such as indium and yttrium are retained in the liver to a greater extent than radioiodine [
14]. Wiseman et al. reported a median estimated radiation-absorbed dose of 3.4 Gy to liver (range 1.2–7.8 Gy), 2.6 Gy to lungs (range 0.72–4.4 Gy), and 0.38 Gy to kidneys (range 0.07–0.61 Gy) for the standard dosing regimen [
15]. Considerable patient-to-patient variability in dosimetry to normal tissues has been seen with Zevalin radioimmunotherapy [
15,
16,
17].
Given that the lungs, or much less commonly the kidneys, received the highest radiation-absorbed dose with 131I anti-CD20 therapy, while the liver received the highest estimated radiation-absorbed dose in 90Y ibritumomab therapies, the non-hematopoietic toxicity of higher-dose 90Y ibritumomab tiuxetan therapy with stem cell support might be expected to be different than that of high-dose 131I tositumomab. In addition, the pure high-energy beta emission of 90Y delivers the vast majority of its energy within the patient without a gamma emission, a practical advantage vs. 131I, which has a 364 keV gamma emission, necessitating substantial radiation safety precautions, including inpatient stays. Further, there is relatively little 90Y excretion from the patient when 90Y monoclonal antibodies are administered, in contrast to the substantial urinary excretion with 131I. Thus, the radiation safety profile for higher-dose 90Y myeloablative RIT with autologous stem cell transplant support lends itself to outpatient therapy. The higher beta energy of 90Y vs. 131I is expected to deliver radiation more uniformly to large tumor foci, also a potential advantage for RIT with 90Y.
Two groups have reported on the use of myeloablative doses of Y-90 Ibritumomomab Tiuxetan in the treatment of NHL. In both studies, dose escalations were based on escalating mBq/kg dosing cohorts informed by planar dosimetry imaging methods, not including SPECT/CT. Target liver radiation-absorbed doses were not to exceed 20 Gy [
16]. Planar imaging is not as accurate as SPECT/CT imaging, indeed there is considerable variability among dosimetry approaches on the same datasets [
16].
It is increasingly possible to perform accurate quantitative SPECT dosimetry with CT-based attenuation correction. One approach is to perform multiple SPECT/CT studies over time [
10]. Another approach is to ascertain the shape of the time-activity curve for an organ from planar imaging and adjust its precise height using SPECT/CT performed at one or more time points [
18,
19]. Prospectively performing organ dosimetry in individual patients has technical and logistical challenges. In the present study, we sought to determine the feasibility of such a real-time approach in patients with lymphoma to allow for substantial prospective precision dose escalation.
Thus, we conducted a phase I dose escalation study of 90Y ibritumomab tiuxetan using 111In ibritumomab tiuxetan as a surrogate for 90Y ibritumomab tiuxetan, for treatment planning in patients with CD20-positive NHL, guided by more accurate organ-specific dosimetry determined by hybrid SPECT/CT and planar imaging. The goals of our study were to determine (a) the feasibility of SPECT/CT + planar prospective real-time dosimetry for guiding individual patient administered radioactivity levels, (b) the feasibility of fully outpatient RIT with ASCT support, (c) to estimate the non-hematological MTD of this treatment approach, especially as related to radiation-induced hepatotoxicity (up to 30.5 Gy) and marrow re-engraftment, and (d) to preliminarily assess the therapeutic activity of this treatment regimen in patients with resistant or refractory CD20-positive, non-Hodgkin’s lymphoma.
2. Methods
The study was performed as a prospective, two-center, dose-escalation study of
90Y ibritumomab tiuxetan, with dose escalation based on prospective patient-specific organ dosimetry determined from
111In ibritumomab tiuxetan imaging. The primary operational goal of the study was to determine if precision, prospective, SPECT-CT organ dosimetry-based outpatient myeloablative radioimmunotherapy, with autologous stem cell transplantation (ASCT), in a two-center study was logistically feasible. The primary clinical goal was to determine the non-hematopoietic MTD of 90Y ibritumomab tiuxetan, with rituximab in vivo purging and ASCT support, using the precision dosing method. The study was conducted according to the guidelines of the Declaration of Helsinki, was approved by the IRBs of the two participating sites (IRB# NA_00036237), and written informed consent was secured for all patients. The trial was initiated before the
clinicaltrials.gov (accessed on 5 June 2021) registration procedure was required.
Inclusion criteria: Eligible patients had relapsed or refractory CD20-positive low-grade, mantle cell, or diffuse large-cell NHL, rituximab sensitivity (rituximab-sensitive defined as at least partial response to rituximab or rituximab-containing regimen and response duration of at least 6 months), and age > 18 years. In addition, patients had to have acceptable function of bone marrow (platelet count ≥ 75,000/mm3, WBC ≥ 3000/mm3, lymphomatous marrow involvement < 35%), and adequate liver, heart, and kidney function (creatinine ≤ 2 mg/dL, direct bilirubin ≤ 2 mg/dL, LVEF ≥ 45%, DLCO > 50%). Patients had to have an anatomically measurable tumor.
Theranostic regimen: In the first phase of the theranostic regimen, rituximab (375 mg/m2) was administered weekly for 4 consecutive weeks, followed by a single dose of cyclophosphamide (2.5 g/m2). Filgrastim 10 mcg/kg was administered after cyclophosphamide until stem cell collection. Patients with successful stem cell collection (at least 2 × 106 CD34 cells/kg) proceeded to RIT. In the second phase of the treatment, on Day 1, patients were given a dosimetric dose of 111In ibritumomab tiuxetan (185 MBq), followed by planar scans and blood sampling at 0–1, 4, 24, 72, and 144 h post-tracer injection and a quantitative SPECT/CT at 24 h. Hybrid planar-SPECT quantification and MIRD dosimetry with liver mass corrections were used to evaluate organ doses. On Day 15, 90Y ibritumomab tiuxetan was administered at a cohort-specific radiation-absorbed dose based on the results of the organ dosimetry. Stem cell infusion occurred when estimated marrow dose rate was <1 cGy/hour. Estimates of bone marrow radiation-absorbed dose were based on the most conservative estimates of dose obtained from blood and image-based marrow dosimetry.
The study schema is shown in
Figure 1. The theranostic procedures were performed at two different physical sites, though dosimetry was calculated at a single site, Johns Hopkins University School of Medicine. A total of 13 patients were treated with
90Y ibritumomab tiuxetan at Johns Hopkins University, Baltimore, MD, and 5 at the University of Wisconsin, Madison, WI, USA.
A modified continual reassessment method (CRM) dose escalation was used to determine the target radiation-absorbed dose for each cohort. The CRM was initiated by assuming a 10% response would occur from 10 Gy and a 90% response would occur from 35 Gy delivered to the liver. The probability of toxicity was assumed to follow a logistic dose response model which was updated after each cohort. The initial cohort received the standard 14.8 MBq/kg (0.4 mCi/kg) dose of
90Y, irrespective of predicted organ dose. Dose cohorts determined by this method were 14.8 MBq/kg and (maximum liver-absorbed dose of
90Y RIT) 14–18, 24, 28, and 30.5 Gy in Cohorts 1–5, respectively [
20].
2.1. Patient Population
The patient population is shown in
Table 1. Median patient age was 55 and median number of prior therapies was 3. Follicular lymphoma, transformed follicular lymphoma, and mantle cell lymphomas were the most common histologies, and 24 patients were entered in the study. Six patients failed to mobilize adequate numbers of stem cells and did not receive
111In dosimetric/biodistribution scans nor
90Y RIT.
2.2. Imaging and Dosimetry
The predicted organ doses and the patient-specific administered radioactivity levels for each patient were calculated using a combination of planar whole-body images acquired at five time points and two SPECT/CT images acquired at one time point. The imaging was performed with a GE Millenium VG/Hawkeye SPECT/CT system with a 1.5875 cm thick crystal at both performance sites. The whole-body images were acquired at, nominally, 0–2, 4, 24, 72, and 144 h post-infusion of
111In ibritumomab tiuxetan. Images were acquired in 14% wide-energy windows centered on both
111In photo-peaks and corrected for scatter using the TEW method with a 152 keV ± 4% scatter window below the lower photo-peak and a 205 keV ±10% scatter window between the two photo-peaks. A source with known activity was included in the whole-body scan and used to adjust for sensitivity variations, and planar images of the source were used to measure the system’s sensitivity for SPECT image quantification. Whole-body images were scatter-corrected using the TEW method (assuming no counts above the upper photo-peak), the geometric mean from opposing views was calculated, and the resulting voxel values converted to activity using the counts from the first time point and the assumption that all activity was retained in the body at the first time point. Details and evaluation of the quantitative methods are provided in several references [
18,
19,
21,
22]. SPECT/CT of the thorax and upper abdomen was performed at 24 h post-injection and reconstructed using vendor supplied software that included attenuation and TEW scatter corrections. These regions of the body were selected to allow estimation of the activity distribution in the dosimetrically important organs, i.e., the lungs and liver.
The predicted radiation-absorbed dose and the administered therapeutic dose for each patient were calculated using the above images using hybrid SPECT/planar methodology [
19,
22]. Whole-organ volumes of interest (VOIs) were manually defined using both the CT and SPECT images and quantified activity in the major organs. It was sometimes difficult to determine which voxels belong to the liver due to the limited resolution of the SPECT/CT images and high uptake at 24 h post-administration in the spleen and heart. In this case, we included only voxels in the liver VOIs that were certain to represent liver tissue. Projections of the SPECT organ VOIs were used to guide manual definition of regions-of-interest in the planar geometric mean images. The whole-body geometric mean images were quantified using the assumption that all the activity was present in the 0–2 h images and corrected for sensitivity variations using a VOI defined over the standard source image. Time-activity curves were generated from the planar images, adjusted for radioactive decay to represent
90Y activity, fit with mono- or bi-exponentials, and rescaled so that the activity for each organ was equal to the activity for that organ at the time of the SPECT/CT acquisition. These curves were integrated and divided by the administered
111In activity to give the residence time (time-integrated activity coefficients) for each organ. Specific doses (radiation-absorbed dose per unit administered activity) were calculated from the residence times using MIRD methodology, as implemented in the MIRDose 3.0 code. The appropriate gender for each patient was used. The liver dose was mass corrected, as described above, based on the volume of the liver VOI, an assumed density of 1.0 g/cc for the liver, and the standard organ mass for the appropriate gender. This method is equivalent to using a VOI smaller than the full liver to estimate the activity concentration in the liver and estimating the total liver activity from this activity concentration and the liver volume based on the standard liver volume of the MIRD phantom. The accuracy of this methodology has been validated in [
23]. The target administered activity needed to give the target dose was estimated by dividing the target liver dose for the cohort by the specific liver activity, calculated as described above. Images, ROIs, VOIs, and dose calculations from the remote performance site were reviewed centrally at Johns Hopkins.
All calculations were completed and reviewed with the PI, and the patient-specific treatment dose was administered at approximately 15 days post-administration of the planning dose. Representative whole-body images and SPECT/CT images with regions of interests selected are shown in
Figure 2, which illustrates the theranostic dosimetry schema.
2.3. Radiolabeling and Dose Infusion
The 111In ibritumomab tiuxetan and 90Y ibritumomab tiuxetan were prepared from FDA-approved kits supplied by Biogen/IDEC. The kits were designed to provide a 185 MBq (5 mCi) 111In dose for imaging or a maximum of 1.18 GBq (32 mCi)/kit of 90Y. To administer therapeutic doses greater than 1.18 GBq, additional kits were required, each supplying 1.18 GBq of 90Y activity. A commercial nuclear pharmacy formulated the doses (Cardinal Health, Dublin, OH, USA). Given that the patients had received weekly infusions of rituximab for each of the 4 weeks prior to the dosimetric dose, no unlabeled rituximab was administered immediately prior to infusion of the dosimetric or the therapeutic doses. This is in contrast to the FDA-approved clinical therapy approach, in which an infusion of 250 mg/m2 rituximab is given over 1–2 h immediately prior to administration of each of the dosimetric or therapeutic doses. In all cases, patients were treated as outpatients, as their radiation emissions (bremsstrahlung), as assessed by measured radiation levels at one meter following therapy, allowed for them to remain as outpatients in compliance with state and NRC radiation safety guidelines. No post-treatment dosimetric imaging was performed.
2.4. Stem Cell Reinfusion
Stem cells were reinfused on an outpatient basis when it was predicted that the radiation-absorbed dose to the stem cells would be less than 1 cGy/h. This prediction was based on the higher predictions made from marrow dosimetry calculations based on blood draws and imaging. The blood-based dosimetry involved sequential measurements of residual blood radioactivity following treatment (obtained on the days of imaging), and the image-based dosimetry used the same methodology as for other organs but with VOIs drawn on lumbar vertebrae and the pelvis. Conservative estimates were used so as to minimize the possibility of radiation damage to the reinfused stem cells. The number of stem cells infused varied based on the success of the stem cell mobilization and collection steps with re-engraftment from 7 to 19 days post-reinfusion.
2.5. Follow-Up
The RIT and the stem cell infusions were performed as outpatients; however, patients were closely followed for signs and symptoms of toxicity as they rapidly became lymphopenic and neutropenic following higher doses of 90Y anti-CD20. Patients were managed by the marrow transplantation unit, and if neutropenic fevers or other side effects developed that were not readily manageable as outpatients, patients were admitted to the hospital for additional supportive therapy. Patients were followed regularly for hematological and systemic toxicities, with a special emphasis on hepatic toxicity. Imaging assessments, typically whole-body CT, were performed at 60 days post-90Y RIT and also at approximately 6-month intervals following treatment with response assessed by the International Working Group criteria (IWG), unless there were clinical signs suggesting earlier progression. The study was terminated early due to sale of the drug provider, meaning that completion of the dose escalation, as well as long-term follow-up data are not available.
4. Discussion
We demonstrated the feasibility of a prospective, precision, SPECT-CT + planar organ dosimetry-based, dose escalation, outpatient myeloablative radioimmunotherapy with autologous stem cell transplantation (ASCT) theranostic regimen in patients with extensively pre-treated non-Hodgkin’s lymphoma. This organ dosimetry method was feasible in the short window of time following infusion of the 111In ibritumomab tiuxetan, in a two-center study using a centralized, standardized dosimetry regimen using comparable imaging equipment.
Six of the twenty-four patients entered in the study did not adequately mobilize stem cells sufficiently to advance to transplant, thus eighteen patients received a therapeutic dose of
90Y ibritumomab tiuxetan. The pure beta energy emission of
90Y and the limited excretion of
90Y from the body (approximately 5% urinary excretion) allowed this theranostic approach to be performed within the guidelines of applicable local radiation safety rules without hospitalization for radiation safety considerations [
15]. Four of the eighteen patients treated with
90Y in the study required hospitalization for complications after treatment. A totally outpatient regimen was possible in 78% of the treated patients. This outpatient approach is in contrast to the prior use of
131I tositumomab at high administered radioactivity doses or
131I MIBG, where hospitalizations for radiation isolation are required for days to weeks before patients can be discharged safely from the hospital [
12,
13].
The individualized dosimetry approach applied here allowed 90Y ibritumomab tiuxetan to be delivered safely with relatively modest toxicity, other than that expected to the bone marrow (which was reversed with stem cell transplant) in most cases. The maximum activity administered, 6.33 GBq (171 mCi), was greater than 5 times the FDA-approved maximum administered activity (32 mCi) for non-myeloablative treatment.
Notable is that the liver radiation-absorbed dose of 28 Gy in 4 patients was well tolerated. This single dose of internally administered radiation to the liver in patients without liver disease suggests the MTD lies above 28 Gy radio-antibody radiation delivery to the liver. We presume the liver uptake of the radio-antibody is uniformly delivered to the hepatocytes. These data build upon those reported by Cremonesi whose trial limited planned Y-90 zevalin dose delivery to the liver to 20 Gy [
16]. Our data also build upon the results of Chiesa, whose highest radiation-absorbed dose to liver was 24.3 Gy, in a patient receiving 45 MBq/kg of Y90 zevalin [
17]. Knowledge that the MTD to the liver from radio-antibodies labeled with Y90 exceeds 28 Gy expands our knowledge of liver radiosensitivity to internally administered radio-pharmaceuticals. Using conventional fractionated external beam irradiation, the maximum tolerated radiation-absorbed dose to the liver is estimated as 30 Gy [
24]. Standard fractionation is typically delivered as 200 cGy/day × 5 days/week [
25]. The initial dose rate from Y90 ibritumomab tiuxetan is likely somewhat higher than that of external beam irradiation due to the 64 h half-life of Y90, but the lack of hepatic toxicity with Y90 suggests that the internally delivered radiation is no more toxic than external beam radiation. While biologic effective dose (BED) is in theory more relevant, it is very hard to confidently determine BED due to uncertainties in underlying assumptions in the liver.
Dosimetry data to the liver from radiolabeled microspheres is difficult to directly compare to the more uniform delivery of radio-antibodies to the hepatocytes. Since microspheres are delivered intra-arterially and lodge in pre-capillary arterioles, they are expected to have a non-uniform dose delivery to the liver, with more dose to tumor than liver [
20].
There have been multiple other studies in which
90Y ibritumomab tiuxetan has been combined at the standard dose of 14.8 MBq/kg with myeloablative chemotherapies and stem cell transplant [
25,
26,
27]. These do not provide information about the MTD of
90Y ibritumomab tiuxetan monotherapy at myeloablative radiation dosing but have generally supported the safety of including standard dose ibritumomab tiuxetan RIT as part of a myeloablative treatment regimen in NHL.
90Y ibritumomab tiuxetan has been given at myeloablative doses as a single agent on an inpatient basis. Ferruci et. al. performed a dose-escalation study in 13 patients at the following dose levels, 29.6 MBq/kg (0.8 mci/kg), 44.4 MBq/kg (1.2 mCi/kg), and 55.5 MBq/kg (1.5 mCi/kg), expanded upon by Cremonesi [
16,
28]. Using the planar dosimetry approach, they also showed considerable variability in the predicted organ radiation-absorbed doses per unit activity administered. They also found that the greatest radiation-absorbed dose per unit activity was to the liver, with hepatic radiation-absorbed dose consistently exceeding that delivered to the lungs or the myocardium. While fairly large administered radio-activities of
90Y were administered, median liver radiation-absorbed doses in the three dose cohorts were 7.2, 11.7, and 13 Gy, although these doses were not prospectively determined. In one patient, an estimated liver dose of 23.4 to 31 Gy (depending on method) was reportedly delivered. Two patients developed febrile neutropenia, one patient had HSV pneumonia, one patient had bacterial pneumonia, and one patient had reactivation of hepatitis C with eventual death without evidence of residual tumor at death. The authors concluded that the highest administered activity dose was appropriate only for patients who had had 3 or fewer regimens of prior chemotherapy and whose platelet counts were >150,000 mm
3. They suggested that the lower dose of 44.4 MBq/kg (1.2 mCi/kg) was appropriate for patients who were more heavily pre-treated or whose platelet counts were in the 100,000–150,000 range.
Given the considerable variability in organ dose reported by Ferruci et al., in two instances, one at the highest planned dose (55.5 MBq/kg) and in one case at the middle dose level (44.4 MBq/kg), the liver radiation-absorbed dose exceeded the upper limit they planned to give. For example, at the 55.5 MBq/kg range, the authors predicted liver radiation-absorbed doses of 7.9 to 31 Gy [
27]. The variability in radiation-absorbed dose to organs per unit administered activity they observed is consistent with the up to 3.5-fold variance we saw in our study in the radiation-absorbed dose per unit activity to the liver/kg body weight using our hybrid SPECT/CT-planar method. We have previously shown that this hybrid dosimetry approach is more accurate than conventional planar methods [
19,
22], possibly accounting for some of the differences between the two reports in absolute radiation-absorbed dose delivery. Cremonesi has pointed out the considerable variability in radiation-absorbed dose estimation depending on the dosimetry approach chosen for planar imaging. These differences are less in larger organs, however [
16].
The determination of an MTD based on administered activity per unit body weight is challenging if the radiation-absorbed dose delivered is highly variable as a function of activity per unit mass. This is clearly the case with
90Y ibritumomab tiuxetan. We targeted delivery of up to 30.5 Gy to the liver without hepatic toxicity using organ-based dosimetry. While only one patient was treated at this planned dose level, three were treated at the 28 Gy level and 6 at the 24 Gy level, and had no evidence of liver toxicity. Thus, the MTD of 13 Gy to the liver proposed by Ferruci et al. is less than half of the dose we were able to safely deliver in our study, and is well under the hepatic radiation-absorbed dose accepted as the MTD for external beam radiation [
24]. While the administered activity/weight-based MTD that they propose may be sufficient to deal with the occasional patient with a high hepatic radiation-absorbed dose, it appears to substantially underestimate the quantity of radioactivity that could be delivered to the liver if accurate prospective dosimetry was performed to guide the administered activity.
Devizzi et al. conducted a study in which chemotherapy was first given to NHL patients, followed by administration of a 29.6 to 44.4 MBq/kg dose of
90Y ibritumomab tiuxetan, followed by stem cell transplant [
29]. Toxicity was generally acceptable [
29,
30]. In this study, planar dosimetry was performed. The liver was the organ receiving the highest radiation-absorbed dose per unit activity (except for spleen), and in 4 patients treated at the 44.4 MBq/kg dose, a median liver radiation absorbed dose of 20.9 Gy with a range of 15.4 to 24.3 Gy was seen without hepatic toxicity. The authors predicted that they could have given higher doses to the liver based on calculations of relative biological efficacy [
17,
29]. Our data support their view. It is difficult to compare other toxicities to our study in that the patients studied by Devizzi had 6 cycles of chemotherapy before the RIT dose and a tandem stem cell transplant procedure, and ours had only rituximab therapy.
We did not escalate the dose sufficiently to determine the MTD in our study. Unfortunately, due to a change in ownership of the company making the drug 90Y ibritumomab tiuxetan, our study was terminated prematurely. Liver tolerance of these radiation-absorbed doses was quite acceptable, suggesting room for further escalation of dose to the liver before an MTD is achieved. Unlike the study by Ferruci, we had no challenges with engraftment of stem cell reinfusions and cannot confirm that a low starting platelet count is a contraindication to high-dose therapy if there are adequate numbers of stem cells infused. Our entry criteria allowed patients with platelet counts of >75,000 mm3 and higher to enter the study, as well as patients who had up to 35% bone marrow involvement.
90Y ibritumomab tiuxetan has been investigated as a stem cell transplant agent in patients with multiple myeloma in combination with high-dose melphalan. Using
111In ibritumomab tiuxetan for dosimetry and cohorts with radiation-absorbed doses to the liver of 10, 12, 14, 16, 18, and 20 Gy, a dose limit was identified in 3 patients, yielding a maximum tolerated liver radiation-absorbed dose of 18 Gy for this treatment [
31].
Our observations on dosimetry support the MTD of
90Y ibritumomab given without immediately preceding chemotherapy as being greater than 28 Gy to the liver. Our study also showed considerable biological and dosimetric variability in the absorbed dose to the liver and other tissues as a function of the activity per unit mass of ibritumomab tiuxetan administered [
29]. We believe our estimates to radiation-absorbed dose variability are more reliable than those previously reported with only planar imaging. These point to the clear advantage of patient-specific dosimetry to safely optimize dose escalation.
Winter et al. integrated a somewhat higher than standard dose ibritumomab tiuxetan therapy with chemotherapy as part of a myeloablative transplant regimen [
32]. They used personalized dosimetry to integrate ibritumomab tiuxetan RIT into the high-dose BEAM chemotherapy regimen for patients with relapsed or refractory CD20+ non-Hodgkin’s lymphoma (NHL). Several dose cohorts were studied with up to 17 Gy to critical organs allowed in the highest dose cohort. The therapeutic dose of
90Y ibritumomab tiuxetan was followed by high-dose BEAM and autologous transplantation. The authors found two dose-limiting toxicities at the 17 Gy dose level, which made 15 Gy the recommended maximum tolerated radiation-absorbed dose. These toxicities were a death at day 10 of pneumonia with renal failure, while another patient at the 17 Gy dose developed septic pulmonary emboli. The authors found that a weight-based strategy using 29.6 MBq/kg (0.8 mCi/kg) would have resulted in a wide range of radiation-absorbed doses to the liver and other tissues: nearly 25% of patient cases would have received 17 Gy or more, and many would have received less than 10 Gy. They concluded that dosimetry is required to avoid toxicity and undertreatment. One would expect the MTD of ibritumomab tiuxetan to be lower when combined with chemotherapy than when given as a monotherapy. The toxicities they observed were consistent with neutropenia, but were not hepatic in nature. Given the small size of our study and the heterogeneous makeup of our patients, it is difficult to make too many conclusions about response rate. However, our 88% response rate with 13 CR and 3 PR out of the 18 patients receiving the therapeutic dose of
90Y ibritumomab tiuxetan compares favorably with the 61.5% response rate (6 CR, 2 PR) in the 13 patients treated with high-dose ibritumomab tiuxetan monotherapy by Ferruci et al. [
28]. Our response rate also compares favorably with the somewhat lower response rates reported for the lower, standard dose (11.1 to 14.8 MBq/kg) ibritumomab tiuxetan therapy of 40% to 60% [
33]. We did not observe a clear difference in response or duration, based on the different dose cohorts studied, so are unable to conclude if higher radiation-absorbed doses truly resulted in superior anti-tumor activity. Concerning, however, was the relatively short duration of many of the responses. This duration of response may be shorter than that which has been reported by Gopal, Press, and colleagues using
131I tositumomab high-dose therapy of lymphoma [
12,
13]. With a median follow-up time of 42 months, the estimated overall and progression-free survival rates were 68% and 42% respectively, which are possibly longer than those seen in our group. It is possible that the differing beta particle energies between
131I and
90Y could be contributing to this possible difference. It is also possible that our patients’ substantial rituximab treatments before RIT reduced tumor targeting of the
90Y ibritumomab tiuxetan.
One patient in our study developed a myelodysplastic syndrome. This is a serious toxicity outcome and is well-known to follow myeloablative transplants, regardless of the method of myeloablation. Our observation is consistent with that of Guidetti et al., who evaluated the hematopoietic damage and incidence of secondary myelodysplastic syndrome and acute myelogenous leukemia (sMDS/AML) in patients who received myeloablative doses of the radiolabeled antibody
90Y ibritumomab tiuxetan. The occurrence of sMDS/AML was investigated prospectively in 53 elderly patients with non-Hodgkin’s lymphoma (NHL) who underwent an autograft after high-dose RIT (HD-RIT) myeloablative conditioning with Y-ibritumomab tiuxetan. The 5-year cumulative incidence of sMDS/AML was 8.29% [
30].
It is important to point out that our approach to ibritumomab tiuxetan therapy differed from standard approaches in several ways: (1) the absolute radiation-absorbed dose given was much higher, and (2) the patients received weekly injections of 375 mg/m
2 rituximab for 4 weeks preceding the radiolabeled antibody doses. The purpose of these infusions in patients who were still judged to be rituximab-sensitive was to purge tumor cells from the circulation before harvesting the stem cells for transplant. While this is a logical approach to clear circulating tumor cells, the amount of unlabeled rituximab given in the 4 weeks preceding the RIT was substantially higher than that typically given prior to RIT, which is 250 mg/m
2 × 2. We did not infuse rituximab immediately prior to either of the ibritumomab tiuxetan infusions as rituximab would remain present in the circulation at the time of the RIT doses based on the typical half-life of rituximab [
34]. We did not measure rituximab levels at the time of radio-antibody infusion. It is known that very high levels of rituximab may reduce the targeting of radiolabeled anti-CD20 antibodies to tumor in animal models [
35]. In addition, there is some suggestive data that rituximab may have some paradoxical radioprotective effects, at least in vitro, which might reduce the biological efficacy of the radiation delivery to tumor [
36]. Other considerations include the possibility that the range of the high-energy beta particle of
90Y may be too long to efficiently deposit energy into small tumor foci. These small foci might be better treated with a less energetic beta particle such as that from
131I or alternative radiotracers with lower beta energies [
37]. A potential limitation of our study is that our predicted radiation dose to the liver is estimated from the ibritumomab tiuxetan imaging studies and not from direct measurement of Y90 activity in the liver, though in general,
111In antibodies are reasonably accurate predictors of
90Y antibody pharmacokinetics [
38]. Since this was not a phase II study nor did we reach the MTD of
90Y ibritumomab tiuxetan, it was not possible to make definitive conclusions on the therapeutic efficacy of high-dose
90Y Ibritumomab tiuxetan in humans, as we did not treat a patient cohort at the MTD, though the treatment was clearly quite active.