Cracking and Fiber Debonding Identification of Concrete Deep Beams Reinforced with C-FRP Ropes against Shear Using a Real-Time Monitoring System
Abstract
:1. Introduction
2. Experimental Program
2.1. Characteristics of the Deep Beams
- Drilling of the holes for the inserted ropes and forming the tassels for the anchorage’s adoption;
- Removing the trapped dust inside the drilled holes with compressed air and a specific tool brush;
- Impregnation of the rope to epoxy resin according to the technical data sheet of the manufacturer
- Filling the grooves of the anchorage’s tassel with epoxy resin;
- Insertion to the holes of the impregnated C-FRP (PZT-bonded) ropes;
- Filling of the holes with epoxy resin to eliminate voiding and to enhance coherence among the inserted materials;
- Final forming of the anchorages by subjecting tension to the end of the ropes;
- Adding extra epoxy resin to smooth the grooves up to the beams’ surface.
- Engraving and carving of channels for the ropes’ insertion and formation of the tassels for the anchorage’s adoption;
- Removing the dust inside the carved channels with compressed air;
- Impregnation of the rope to epoxy resin according to the technical data sheet of the manufacturer;
- Insertion and gliding of the impregnated C-FRP ropes into the formed channels;
- Filling the grooves of the anchorage’s tassel with epoxy resin;
- Filling the channel with epoxy resin to enhance coherence among the inserted materials.
2.2. Materials
2.3. Test Setup
2.4. Electro-Mechanical Impedance (EMI) Method
2.5. Installation of PZT Transducers
- a.
- Two epoxy-bonded PZTs for each beam were located, the first one on the surface of the one steel tensional reinforcing bar and the second one on the surface of the steel flexural reinforcing bar after proper flattening of the bar (internal PZTs), both located in the middle of the steel bar and named as S1 and S2, respectively. An extra layer of the epoxy adhesive was also used thoroughly on the top of each PZT waterproofing and it protects the patches during the concrete casting and curing process to be devoid of noise effects in their extracted electro-mechanical signatures (Figure 5a).
- b.
- Externally epoxy-bonded PZTs mounted to the concrete surface of the beams (external PZTs). A high shear modulus epoxy adhesive with a small thickness was applied to bond the PZTs. Four PZT patches were surficially bonded on the mid-height dimension on the left and right shear span on both sides near and along the length of the ropes’ position. Two more PZTs were externally placed on both sides in the bottom mid-span of the beams. The exact position of the PZT patches is illustrated in Figure 5b. The PZTs’ codified names are denoted as “X1”, “X2”, “X3”, “X4”, “X5”, and “X6”.
- c.
- Two epoxy-bonded PZTs were also internally placed on the R-FRP beam. The PZT patches were simultaneously embedded with the insertion of the ropes inside each drilled hole. The PZT patch was embodied with the rope using an epoxy adhesive and tying the welded wires with the rope carefully using a tire-up component and a steel wire to achieve the final designed position of the PZT patch inside the hole. The targeted tying position was selected so that the PZT patch finally ended up bonded internally to the drilled hole in the middle of the traversing length of the rope. The steel wire was used as an assistant tool for driving the rope, the PZT patch, and its wires passing through the hole and then removed. The two patches are denoted as W1 and W2, respectively (Figure 5c).
3. Results and Discussion
3.1. Loading Test
3.2. Damage Quantification
- RMSD: root mean square deviation;
- MAPD: mean absolute percentage deviation;
- CC: coefficient of correlation.
- : absolute value of the voltage output signal as extracted from the PZT at the healthy pristine state of the specimen,
- : absolute value of the corresponding voltage output signal as measured from the same PZT at damage level ,
- b,n: number of date points in the moving frame,
- M: number of measurements in the frequency band 10–250 kHz.
3.3. Damage Evaluation of the T-FRP beam
3.4. Damage Evaluation of the R-FRP beam
3.5. Comparatively Cases
4. Conclusions
- Both shear strengthening techniques alter the performance of the tested beams to a ductile response. The proposed anchorage method of the fiber ropes enhanced their efficiency by increasing the bearing capacity and improving post-peak response in terms of strength and overall behavior. In addition, the fibers of the ropes did not exhibit rupture or debonding failure. Nevertheless, more experimental data are required to establish the efficacy of this technique.
- The externally epoxy-bonded PZT transducers have successfully detected the loading/damage steps at which the first flexural crack and the initiation of the shear cracking occurred. Furthermore, SHM data support the effectiveness of the applied strengthening technique.
- The internal rope-bonded PZT transducers showed promising results, demonstrating a direct correlation with the mechanical performance of the C-FRP rope, thus contributing as an emerging tool for the early and real-time diagnosis of potential fiber debonding. However, the externally bonded PZTs showed less sensitivity in terms of damage indices’ values compared to the internally bonded ones.
- Cracking through the PZT’s position affects the transducer’s sensitivity as a significant change to the bonding parameters between the patch, and the host structure was observed. The impact of this condition could not be yet quantified numerically, but it should be considered in the evaluation of the acquired data as a probable condition of false damage alert.
- The reliability and sensitivity of the proposed PZT-enabled monitoring technique has been indicated since PZTs placed on the steel reinforcement at the same positions in all of the testing beams (S1T/S1R and S2T/S2R) demonstrate a similar trend of damage indices at the corresponding damage levels. Nevertheless, more tests are required to establish this method for the localization of the cracks and prompt damage detection.
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Aarabzadeh, A.; Hizaji, R. Failure Mechanism in Fixed-Ended Reinforced Concrete Deep Beams under Cyclic Load. World Acad. Sci. Eng. Technol. Int. J. Civil Environ. Eng. 2017, 11, 562–566. [Google Scholar]
- Chalioris, C.E. Steel Fibrous RC Beams Subjected to Cyclic Deformations under Predominant Shear. Eng. Struct. 2013, 49, 104–118. [Google Scholar] [CrossRef]
- Arabzadeh, A.; Karimizadeh, H. Experimental Study of RC Deep Beams with Opening and FRP Composites Installed by Means of EBR and EBROG Methods. Constr. Build. Mater. 2019, 208, 780–791. [Google Scholar] [CrossRef]
- Nie, X.F.; Zhang, S.S.; Teng, J.G.; Chen, G.M. Experimental Study on RC T-Section Beams with an FRP-Strengthened Web Opening. Compos. Struct. 2018, 185, 273–285. [Google Scholar] [CrossRef]
- El-kareim Shoeib, A.; El-Sayed Sedawy, A. Shear Strength Reduction Due to Introduced Opening in Loaded RC Beams. J. Build. Eng. 2017, 13, 28–40. [Google Scholar] [CrossRef]
- El-Sisi, A.A.; El-Emam, H.M.; El-Kholy, A.E.M.I.; Ahmad, S.S.; Sallam, H.M.; Salim, H.A. Structural Behavior of RC Beams Containing Unreinforced Drilled Openings with and without C-FRP Strengthening. Polymers 2022, 14, 2034. [Google Scholar] [CrossRef]
- Chalioris, C.E.; Zapris, A.G.; Karayannis, C.G. U-Jacketing Applications of Fiber-Reinforced Shear—Tests and Design. Fibers 2020, 8, 13. [Google Scholar] [CrossRef] [Green Version]
- Chalioris, C.E. Torsional Strengthening of Rectangular and Flanged Beams Using Carbon Fibre-Reinforced-Polymers-Experimental Study. Constr. Build. Mater. 2008, 22, 21–29. [Google Scholar] [CrossRef]
- Chalioris, C.E. Analytical Model for the Torsional Behaviour of Reinforced Concrete Beams Retrofitted with FRP Materials. Eng. Struct. 2007, 29, 3263–3276. [Google Scholar] [CrossRef]
- Golias, E.; Zapris, A.G.; Kytinou, V.K.; Kalogeropoulos, G.I.; Chalioris, C.E.; Karayannis, C.G. Effectiveness of the Novel Rehabilitation Method of Seismically Damaged Rc Joints Using C-Frp Ropes and Comparison with Widely Applied Method Using c-Frp Sheets—Experimental Investigation. Sustainability 2021, 13, 6454. [Google Scholar] [CrossRef]
- Golias, E.; Zapris, A.G.; Kytinou, V.K.; Osman, M.; Koumtzis, M.; Siapera, D.; Chalioris, C.E.; Karayannis, C.G. Application of X-Shaped C-FRP Ropes for Structural Upgrading of Reinforced Concrete Beam–Column Joints under Cyclic Loading–Experimental Study. Fibers 2021, 9, 42. [Google Scholar] [CrossRef]
- Alam, P.; Mamalis, D.; Robert, C.; Floreani, C.; Ó Brádaigh, C.M. The Fatigue of Carbon Fibre Reinforced Plastics-A Review. Compos. Part B Eng. 2019, 166, 555–579. [Google Scholar] [CrossRef] [Green Version]
- Li, C.; Xian, G. Mechanical Property Evolution and Life Prediction of Carbon Fiber and Pultruded Carbon Fiber Reinforced Polymer Plate Exposed to Elevated Temperatures. Polym. Compos. 2020, 41, 5143–5155. [Google Scholar] [CrossRef]
- Xian, G.; Guo, R.; Li, C.; Wang, Y. Mechanical Performance Evolution and Life Prediction of Prestressed CFRP Plate Exposed to Hygrothermal and Freeze-Thaw Environments. Compos. Struct. 2022, 293, 115719. [Google Scholar] [CrossRef]
- Bazli, M.; Abolfazli, M. Mechanical Properties of Fibre Reinforced Polymers under Elevated Temperatures: An Overview. Polymers 2020, 12, 2600. [Google Scholar] [CrossRef] [PubMed]
- Harmanci, Y.E.; Michels, J.; Chatzi, E. Behaviour of Prestressed C-FRP Anchorages during and after Freeze-Thaw Cycle Exposure. Polymers 2018, 10, 565. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Bilotta, A.; Ceroni, F.; Di Ludovico, M.; Nigro, E.; Pecce, M.; Manfredi, G. Bond Efficiency of EBR and NSM FRP Systems for Strengthening Concrete Members. J. Compos. Constr. 2011, 15, 757–772. [Google Scholar] [CrossRef]
- Oehlers, D.J.; Haskett, M.; Wu, C.; Seracino, R. Embedding NSM FRP Plates for Improved IC Debonding Resistance. J. Compos. Constr. 2008, 12, 635–642. [Google Scholar] [CrossRef]
- Parvin, A.; Shah, T.S. Fiber Reinforced Polymer Strengthening of Structures by Near-Surface Mounting Method. Polymers 2016, 8, 298. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Seo, S.Y.; Feo, L.; Hui, D. Bond Strength of near Surface-Mounted FRP Plate for Retrofit of Concrete Structures. Compos. Struct. 2013, 95, 719–727. [Google Scholar] [CrossRef]
- Breveglieri, M.; Aprile, A.; Barros, J.A.O. Embedded Through-Section Shear Strengthening Technique Using Steel and C-FRP Bars in RC Beams of Different Percentage of Existing Stirrups. Compos. Struct. 2015, 126, 101–113. [Google Scholar] [CrossRef]
- Chaallal, O.; Mofidi, A.; Benmokrane, B.; Neale, K. Embedded Through-Section FRP Rod Method for Shear Strengthening of RC Beams: Performance and Comparison with Existing Techniques. J. Compos. Constr. 2011, 15, 374–383. [Google Scholar] [CrossRef]
- Mofidi, A.; Chaallal, O.; Benmokrane, B.; Neale, K. Experimental Tests and Design Model for RC Beams Strengthened in Shear Using the Embedded Through-Section FRP Method. J. Compos. Constr. 2012, 16, 540–550. [Google Scholar] [CrossRef]
- Fanaradelli, T.D.; Rousakis, T.C. 3D Finite Element Pseudodynamic Analysis of Deficient Rc Rectangular Columns Confined with Fiber Reinforced Polymers under Axial Compression. Polymers 2020, 12, 2546. [Google Scholar] [CrossRef]
- Rousakis, T.C. Hybrid Confinement of Concrete by Fiber-Reinforced Polymer Sheets and Fiber Ropes under Cyclic Axial Compressive Loading. J. Compos. Constr. 2013, 17, 732–743. [Google Scholar] [CrossRef]
- Yang, K.H.; Byun, H.Y.; Ashour, A.F. Shear Strengthening of Continuous Reinforced Concrete T-Beams Using Wire Rope Units. Eng. Struct. 2009, 31, 1154–1165. [Google Scholar] [CrossRef] [Green Version]
- El-Saikaly, G.; Godat, A.; Chaallal, O. New Anchorage Technique for FRP Shear-Strengthened RC T-Beams Using C-FRP Rope. J. Compos. Constr. 2015, 19, 1–11. [Google Scholar] [CrossRef]
- Kaya, E.; Cavunt, Y.S.; Cavunt, D.; Ispir, M.; Ilki, A. Flexural Retrofit of Support Regions of Reinforced Concrete Beams with Anchored FRP Ropes under Reversed Cyclic Loading. J. Compos. Constr. 2016, 21, 1574–1582. [Google Scholar] [CrossRef] [Green Version]
- Chalioris, C.E.; Kosmidou, P.M.K.; Papadopoulos, N.A. Investigation of a New Strengthening Technique for RC Deep Beams Using Carbon FRP Ropes as Transverse Reinforcements. Fibers 2018, 6, 52. [Google Scholar] [CrossRef] [Green Version]
- Halabe, U.B.; Vasudevan, A.; Klinkhachorn, P.; Gangarao, H.V.S. Detection of Subsurface Defects in Fiber Reinforced Polymer Composite Bridge Decks Using Digital Infrared Thermography. Nondestruct. Test. Eval. 2007, 22, 155–175. [Google Scholar] [CrossRef]
- Providakis, C.P.; Triantafillou, T.C.; Karabalis, D.; Papanicolaou, A.; Stefanaki, K.; Tsantilis, A.; Tzoura, E. Simulation of PZT monitoring of reinforced concrete beams retrofitted with C-FRP. Sm. Str. Syst. 2014, 14, 811–830. [Google Scholar] [CrossRef]
- Triantafyllou, G.G.; Rousakis, T.C.; Karabinis, A.I. Effect of Patch Repair and Strengthening with EBR and NSM CFRP Laminates for RC Beams with Low, Medium and Heavy Corrosion. Compos. Part B Eng. 2018, 133, 101–111. [Google Scholar] [CrossRef]
- Giurgiutiu, V.; Harries, K.A.; Petrou, M.F.; Bost, J.; Quattlebaum, J. Disbond Detection with Piezoelectric wafer Active Sensors in RC Structures Strengthened with FRP Composite Overlays. Earthq. Eng. Eng. Vib. 2003, 2, 213–224. [Google Scholar] [CrossRef] [Green Version]
- Kim, S.D.; In, C.W.; Cronin, K.E.; Sohn, H.; Harries, K. Reference-Free NDT Technique for Debonding Detection in C-FRP-Strengthened RC Structures. J. Struct. Eng. 2007, 133, 1080–1091. [Google Scholar] [CrossRef] [Green Version]
- Yu, H.; Seno, A.H.; Khodaei, Z.S.; Aliabadi, M.H.F. Structural Health Monitoring Impact Classification Method Based on Bayesian Neural Network. Polymers 2022, 14, 3947. [Google Scholar] [CrossRef]
- Werner, J.M.; Engelmann, M.; Schmidt, M.; Titsch, C.; Dix, M.; Drossel, W.G. Comparison of Structural Integrated Piezoceramics, Piezoelectric Patches and Strain Gauges for Condition Monitoring. Sensors 2022, 22, 8847. [Google Scholar] [CrossRef] [PubMed]
- Yang, Y.; Divsholi, B.S. Sub-Frequency Interval Approach in Electromechanical Impedance Technique for Concrete Structure Health Monitoring. Sensors 2010, 10, 11644–11661. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Huo, L.; Cheng, H.; Kong, Q.; Chen, X. Bond-Slip Monitoring of Concrete Structures Using Smart Sensors—A Review. Sensors 2019, 19, 1231. [Google Scholar] [CrossRef] [Green Version]
- Divsholi, B.S.; Yang, Y.; Bing, L. Monitoring Beam-Column Joint in Concrete Structures Using Piezo-lmpedance Sensors. Adv. Mater. Res. 2009, 79–82, 59–62. [Google Scholar] [CrossRef]
- Yang, Y.; Hu, Y.; Lu, Y. Sensitivity of PZT Impedance Sensors for Damage Detection of Concrete Structures. Sensors 2008, 8, 327–346. [Google Scholar] [CrossRef] [Green Version]
- Karegar, M.; Bidgoli, M.R.; Mazaheri, H. Smart Control and Seismic Analysis of Concrete Frames with Piezoelectric Layer Based on Mathematical Modelling and Numerical Method. Structures 2021, 32, 1171–1179. [Google Scholar] [CrossRef]
- Sevillano, E.; Sun, R.; Gil, A.; Perera, R. Interfacial Crack-Induced Debonding Identification in FRP-Strengthened RC Beams from PZT Signatures Using Hierarchical Clustering Analysis. Compos. Part B Eng. 2016, 87, 322–335. [Google Scholar] [CrossRef]
- Sun, R.; Sevillano, E.; Perera, R. Debonding Detection of FRP Strengthened Concrete Beams by Using Impedance Measurements and an Ensemble PSO Adaptive Spectral Mode. Compos. Struct. 2015, 125, 374–387. [Google Scholar] [CrossRef] [Green Version]
- Park, S.; Kim, J.W.; Lee, C.; Park, S.K. Impedance-Based Wireless Debonding Condition Monitoring of C-FRP Laminated Concrete Structures. NDT E Int. 2011, 44, 232–238. [Google Scholar] [CrossRef]
- Jiang, T.; Kong, Q.; Patil, D.; Luo, Z.; Huo, L.; Song, G. Detection of Debonding Between Fiber Reinforced Polymer Bar and Concrete Structure Using Piezoceramic Transducers and Wavelet Packet Analysis. IEEE Sens. J. 2017, 17, 1992–1998. [Google Scholar] [CrossRef]
- Chalioris, C.E.; Providakis, C.P.; Favvata, M.J.; Papadopoulos, N.A.; Angeli, G.M.; Karayannis, C.G. Experimental Application of a Wireless Earthquake Damage Monitoring System (WiAMS) Using PZT Transducers in Reinforced Concrete Beams. Earthq. Resist. Eng. Struct. 2015, 1, 233–243. [Google Scholar] [CrossRef] [Green Version]
- Karayannis, C.G.; Chalioris, C.E.; Angeli, G.M.; Papadopoulos, N.A.; Favvata, M.J.; Providakis, C.P. Experimental Damage Evaluation of Reinforced Concrete Steel Bars Using Piezoelectric Sensors. Constr. Build. Mater. 2016, 105, 227–244. [Google Scholar] [CrossRef]
- Perera, R.; Pérez, A.; García-Diéguez, M.; Zapico-Valle, J.L. Active Wireless System for Structural Health Monitoring Applications. Sensors 2017, 17, 2880. [Google Scholar] [CrossRef] [Green Version]
- Chalioris, C.E.; Karayannis, C.G.; Angeli, G.M.; Papadopoulos, N.A.; Favvata, M.J.; Providakis, C.P. Applications of Smart Piezoelectric Materials in a Wireless Admittance Monitoring System (WiAMS) to Structures-Tests in RC Elements. Case Stud. Constr. Mater. 2016, 5, 1–18. [Google Scholar] [CrossRef] [Green Version]
- Voutetaki, M.E.; Naoum, M.C.; Papadopoulos, N.A.; Chalioris, C.E. Cracking Diagnosis in Fiber-Reinforced Concrete with Synthetic Fibers Using Piezoelectric Transducers. Fibers 2022, 1, 5. [Google Scholar] [CrossRef]
- Chalioris, C.E.; Kytinou, V.K.; Voutetaki, M.E.; Karayannis, C.G. Flexural Damage Diagnosis in Reinforced Concrete Beams Using a Wireless Admittance Monitoring System—Tests and Finite Element Analysis. Sensors 2021, 21, 679. [Google Scholar] [CrossRef]
- Shan, B.; Pan, Y.; Huo, X.; Xian, G. Detection of Slip for CFRP-Concrete Interface Using Stereovision Method Corrected by Epipolar Constraint. Struct. Control Heal. Monit. 2018, 25, 1–16. [Google Scholar] [CrossRef]
- Karayannis, C.G.; Golias, E.; Naoum, M.C.; Chalioris, C.E. Efficacy and Damage Diagnosis of Reinforced Concrete Columns and Joints Strengthened with FRP Ropes Using Piezoelectric Transducers. Sensors 2022, 22, 8294. [Google Scholar] [CrossRef]
- Voutetaki, M.E.; Naoum, M.C.; Papadopoulos, N.A.; Sapidis, G.; Chalioris, C.E. Cracking Diagnosis in Fibre Reinforced Concrete Cubes and Cylinders with Synthetic Fibres Using a PZT-Based Health Monitoring System. Sch. J. Eng. Techn. 2021, 9523, 140–151. [Google Scholar] [CrossRef]
- Wang, Z.; Chen, D.; Zheng, L.; Huo, L.; Song, G. Influence of Axial Load on Electromechanical Impedance (EMI) of Embedded Piezoceramic Transducers in Steel Fiber Concrete. Sensors 2018, 18, 1782. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Balamonica, K.; Saravanan, T.J.; Priya, C.B.; Gopalakrishnan, N. Piezoelectric Sensor–Based Damage Progression in Concrete through Serial/Parallel Multi-Sensing Technique. Struct. Heal. Monit. 2020, 19, 339–356. [Google Scholar] [CrossRef]
- Providakis, C.; Tsistrakis, S.; Voutetaki, M.; Tsompanakis, J.; Stavroulaki, M.; Agadakos, J.; Kampianakis, E.; Pentes, G.; Liarakos, E. An Innovative Active Sensing Platform for Wireless Damage Monitoring of Concrete Structures. Curr. Smart Mater. 2016, 1, 49–62. [Google Scholar] [CrossRef]
- Naidu, A.S.K.; Soh, C.K. Damage Severity and Propagation Characterization with Admittance Signatures of Piezo Transducers. Smart Mater. Struct. 2004, 13, 393–403. [Google Scholar] [CrossRef]
- Voutetaki, M.E.; Papadopoulos, N.A.; Angeli, G.M.; Providakis, C.P. Investigation of a New Experimental Method for Damage Assessment of RC Beams Failing in Shear Using Piezoelectric Transducers. Eng. Struct. 2016, 114, 226–240. [Google Scholar] [CrossRef]
Material | Mechanical Properties | |
---|---|---|
Impregnated C-FRP rope SikaWrap FX-50C | Laminate tensile strength | 2100 GPa |
Laminate modulus of elasticity in tension | 230 GPa | |
Laminate elongation at break in tension | 0.87% | |
Sikadur 300 | Tensile strength | 45 MPa |
Modulus of elasticity in tension | 3.5 GPa | |
Sikadur 330 | Tensile strength | 30 MPa |
Modulus of elasticity in tension | 4.5 GPa | |
Sika Anchorfix 3+ | Sikadur 3+ compressive strength | 114 MPa |
Condition | Frequency (kHz) | |
---|---|---|
S1T | S2T | |
Healthy | 228 | 225 |
Dam 1 | 214 | 225 |
Dam 2 | 208 | 224 |
Dam 3 | 209 | 221 |
Dam 4 | 206 | 213 |
Dam 5 | 205 | 207 |
Dam 6 | - | 196 |
Dam 7 | - | 195 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Papadopoulos, N.A.; Naoum, M.C.; Sapidis, G.M.; Chalioris, C.E. Cracking and Fiber Debonding Identification of Concrete Deep Beams Reinforced with C-FRP Ropes against Shear Using a Real-Time Monitoring System. Polymers 2023, 15, 473. https://doi.org/10.3390/polym15030473
Papadopoulos NA, Naoum MC, Sapidis GM, Chalioris CE. Cracking and Fiber Debonding Identification of Concrete Deep Beams Reinforced with C-FRP Ropes against Shear Using a Real-Time Monitoring System. Polymers. 2023; 15(3):473. https://doi.org/10.3390/polym15030473
Chicago/Turabian StylePapadopoulos, Nikos A., Maria C. Naoum, George M. Sapidis, and Constantin E. Chalioris. 2023. "Cracking and Fiber Debonding Identification of Concrete Deep Beams Reinforced with C-FRP Ropes against Shear Using a Real-Time Monitoring System" Polymers 15, no. 3: 473. https://doi.org/10.3390/polym15030473
APA StylePapadopoulos, N. A., Naoum, M. C., Sapidis, G. M., & Chalioris, C. E. (2023). Cracking and Fiber Debonding Identification of Concrete Deep Beams Reinforced with C-FRP Ropes against Shear Using a Real-Time Monitoring System. Polymers, 15(3), 473. https://doi.org/10.3390/polym15030473