1. Introduction
Radon is a naturally occurring radionuclide that is released into the atmosphere as a gas during the decay process of its parent nuclide uranium (
238U) in the ground. Radon gas is colorless, odorless, and difficult to directly identify, thereby posing a serious health risk in indoor environments, such as homes [
1,
2,
3,
4]. It has a half-life of approximately 3.8 days, and when it enters an indoor space in a chemically inert gaseous state, the human body can be easily exposed to it via respiration [
5,
6,
7,
8]. Radon from various sources has been reported to be deposited in the lungs via respiration and can cause damage to the cells owing to an internal exposure to radiation [
9]. According to the Environmental Protection Agency (EPA) in the United States, approximately 21,000 people die annually from lung cancer induced by radon, and they emphasized that, after smoking, the second most common cause of death from lung cancer is radon exposure [
10]. The International Agency for Research on Cancer (IARC, France) designated radon as a class 1 carcinogen in terms of harmfulness to human health and body [
2]. Radon gas is mainly generated from the soil where buildings are constructed, from where it partially flows into the indoors through gaps and cracks in buildings. In addition, radon gas generated from building materials in indoor spaces is also known to be a major potential source of radon contamination [
11,
12,
13,
14,
15].
Keller et al. (2001) verified the possibility of radon exhalation from building materials in indoor spaces. However, because exhalation may be low owing to individual effects of building materials such as the degree of sealing and airtightness, as well as structural differences, it is necessary to verify radon concentration by direct investigations in actual indoor spaces [
16]. Concentrated evaluations of specific building materials are necessary for radon exhalation from building materials; however, there have been instances in which radon exhalation rates 5 to 9 times higher were investigated depending on the structure of the apartment housings and the influence of the building materials, and building materials directly exposed to the interior have been identified as factors that can determine indoor radon concentrations [
17]. In houses with successful air exchange, radon exhalation from building materials do not significantly affect the indoor air quality [
18]. Meanwhile, the absence of ventilation can cause health hazards owing to the accumulation of radon gas, even in environments with low exposure to radon [
19].
Therefore, various environmental parameters, such as indoor decompression level, meteorological condition, ground and building characteristics, air exchange rate, and ventilation type can influence both the radon influx into a building and the associated indoor radon concentration. In addition, these parameters can affect indoor radon dilution, and regardless of the use of a building, proper ventilation is crucial for radon reduction [
20]. Currently, research in South Korea on national standards such as the guidelines for the management of radon reduction in apartment housings via ventilation and other means has commenced; however, available fundamental data are insufficient. Hence, prompt and reliable reduction measures are required for indoor living environments.
This study was performed to evaluate various effects of indoor radon ventilation in apartment housings, which is the most common type of residence in South Korea, and to provide baseline data for the development of South Korean ventilation guidelines. This study was conducted in an actual living environment to provide baseline data for radon research, which is subject to uncertainties triggered by the effects of various parameters.
3. Results
3.1. Radon Reduction from Each Natural Ventilation Conditions
Natural ventilation was performed according to each scenario from Cases 1 to 7, and the results obtained from the comparison of indoor radon concentrations are presented with the recommended standards 148 Bq/m
3 by Ministry of Environment, Korea (
Figure 3). C
r was calculated to identify the indoor radon increase/decrease ratios according to each scenario (
Figure 4), while C
0 and C
min were demonstrated to identify the radon reduction rates according to each scenario (
Figure 5 and
Table 2).
In Case 1, after natural ventilation, radon concentration decreased from 134.73 Bq m−3 to 14.71 Bq m−3 in the living room and from 163.29 Bq m−3 to 10.83 Bq m−3 in the room, with high reduction rates of 89.08% and 93.37%, respectively. In Case 2, where the natural ventilation system equipment was operated, the decrease in radon concentration was inconsistent, and the concentration was higher than the standard value of 148 Bq m−3 during ventilation. After 1 h of ventilation in the living room and 2 h in the room, low reduction rates of 20.27% and 11.62% were observed, respectively. In addition, the concentration ratio increased to 1.46 and 1.19 in the living room after 4 h of ventilation and in the room after 3 h of ventilation, respectively. In Case 3, the concentration in the living room with direct ventilation decreased from 86.90 Bq m−3 at the onset of ventilation to 4.01 Bq m−3 after 5 h, thereby exhibiting a high reduction rate of 95.38%. Here, the Cr value was 0.05, which was the lowest value among the ventilation scenarios in the living room and the room. Meanwhile, in the room without direct ventilation, the concentration after ventilation reduced from 140.09 Bq m−3 to 88.29 Bq m−3, which was a relatively low reduction at 36.98%. In Case 4, where independent ventilations proceeded with the door connecting the living room and the room closed, the reduction rates were 64.54% and 90.42% in the living room and the room, respectively. In Case 5 where ventilation proceeded solely in the living room, the living room exhibited a 90.53% reduction from 127.01 Bq m−3 to 12.03 Bq m−3 after 3 h of ventilation, while the room exhibited a 59.39% reduction. Similarly, in Case 6, where ventilation solely proceeded in the living room, the reduction rate in the living room was 84.04% from 92.25 Bq m−3 to 14.72 Bq m−3, while that of the room was 46.72%. In Case 6, the Cr value of the room was 1.09 after 1 h from the onset of ventilation, the radon concentration decreased after a partial increase, and the initial concentration of 198.49 Bq m−3 decreased to 111.48 Bq m−3 after a 3-h ventilation, which was below the standard value. In Case 7, which was ventilated by opening only the door and window of the room while leaving the window in the living room completely closed, the reduction rate was 92.38% in the living room and 93.13% in the room, both exhibiting high reduction rates. The concentration in the room after 1 h of ventilation decreased from 157.63 Bq m−3 to 73.15 Bq m−3, which was confirmed as equal to or below the standard value.
In Cases 3, 5, and 6, when all the doors and windows of the room were closed, and only the ventilation conditions in the living room were differentiated, it was confirmed that the radon concentrations in the room and living room reduced simultaneously. However, the reduction rates were relatively low, 60% or less. In the living room, the highest concentration rate was observed in Case 3, followed by Cases 5 and 6. In Case 4, where ventilations were conducted in independent spaces, the reduction rates were 64.54% and 90.42% in the living room and room, respectively, thereby indicating a higher reduction rate in the relatively smaller space.
Radon concentrations decreased to low levels of 4.01–22.76 Bq m−3 after ventilation in the remaining scenarios, excluding the rooms in Cases 3, 5, and 6, where windows and rooms were not opened for ventilation, and in Case 2 where the natural ventilation system was employed.
3.2. Radon Reduction from Mechanical Ventilation Conditions
The results obtained from the comparison of indoor radon concentrations from each mechanical ventilation condition, which were categorized into high, middle, and low operational intensities, are provided natural ventilation was performed according to each scenario from Cases 1 to 7, and the results obtained from the comparison of indoor radon concentrations are presented with the recommended standards 148 Bq/m
3 by Ministry of Environment, Korea (
Figure 6). In addition, C
r values were calculated to identify the indoor radon increase/decrease ratios (
Figure 7), while C
0 and C
min values were presented to identify the radon reduction rates according to each scenario (
Figure 8 and
Table 3).
Before the high mechanical ventilation, the radon concentration in the living room was at 174.11 Bq m−3, which exceeded the standard value of 148 Bq m−3. After 1 h of ventilation, it was reduced to a value below the standard value, at a reduction rate of a 54.7%. In the room, after the Cr value increased to 1.19 after 1 h of ventilation, the concentration gradually decreased and exhibited a 31.87% reduction rate. In the middle mechanical ventilation condition, the radon concentration after 1 h in the living room had not changed from before the ventilation, which after the partial increase in concentration and the increase in Cr to 1.02 after 2 h of ventilation exhibited a 31.03% reduction rate after 3 h of ventilation. The radon concentration in the room was reduced from 126.38 Bq m−3 to 51.61 Bq m−3 by 59.16%. In the low mechanical ventilation condition, the living room and room exhibited reduction rates of 41.65% and 65.66%, respectively, and the Cr value was the lowest value at 0.34 among the living room and room ventilation conditions.
In the high mechanical ventilation condition, the reduction rate was higher in the living room than in the room; however, in the middle and low mechanical ventilation conditions, the reduction rate was higher in the room with a smaller area than the living room.
4. Discussion
In a household located on the 12th floor of a newly constructed apartment building, it could be considered that radon is commonly emitted from the soil in the housing facilities of the upper floors and the newly constructed buildings, and the influence of radon inflow through cracks in buildings is low indoors. However, in this study, it was verified to be at the standard value of 148 Bq m
−3 or above, but without ventilation. Results obtained from a previous study results indicated that in a 2017 survey from the National Geographic Information Institute of the Ministry of Land, Infrastructure, and Transport, in certain areas of South Korea, the radon concentrations in apartments and multiunit housing in the form of apartment housing were determined to be at 148 Bq m
−3 (or above) or approaching the standard value [
22]. This implies that in the apartment housing, the most common residence type in South Korea, despite being on upper floors in newly constructed apartment, exposure to radon above the standard value is possible, which required suitable radon management by studies on indoor radon. The target household of this study was geologically located in the sedimentary rock zone and surrounded by Daebo granites and biotite granite zones. The radon from the indoor air of the target household was estimated to have been generated from the indoor building materials or the soil, which traveled through the pipes and infiltrated the upper floors.
In this study, the rooms were sealed for more than 4 h before the start of ventilation because the radon reduction effect of ventilation could be underestimated if the ventilation began when the room radon concentration was distributed at a low level during the measurements. In Case 1, under the natural ventilation measurement condition, high reduction rates of 89.08% and 93.37% were observed in the living room and the room, respectively, and it was confirmed that the radon concentration could be reliably reduced by opening all the windows in the living space. Furthermore, in Case 1, the radon concentration in the living room decreased to the lowest level within 3 h after the start of ventilation, thus indicating that the ventilation of the entire household, even for a short period, is effective for indoor radon management. However, in Case 2, the reduction rate of 20.27% and 11.62% in the living room and room, respectively, indicated that the radon concentration increased above the standard during ventilation. Based on this result, it was considered that the operating natural ventilation system equipment can support the redistribution of indoor air in the apartment housing; however, when used alone, it is difficult to control the indoor radon concentration via ventilation. Comparing the results of Cases 3, 5, and 6, in which ventilation activities proceeded in the living room while the room windows remained closed, the reduction rates were 95.38%, 90.53%, and 84.04%, respectively, with higher reduction rates in the living room in the order of Cases 3, 5, and 6. This indicated that the ventilation method of opening both the living room windows in Case 3 is more effective than the method of opening one of the windows in Case 6, and the bidirectional ventilation through the opposing window in Case 5 is more effective than the unidirectional ventilation in Case 6. In Case 4, where the room door was closed and independent ventilation proceeded in the living room and room, the reduction rate was as high as 90.42% in the room, while the living room exhibited a relatively low reduction rate of 64.54%. In addition, a difference of 30.85% was observed, compared to the reduction rate of 95.38% in the living room of Case 3, which was ventilated with the room door closed. This implies that ventilation in a small space is more effective than in a large space, and the ventilation through a wide window is more effective than ventilation through a narrow window. In Case 6, the radon concentration in the room increased immediately after the beginning of ventilation and decreased 1 h later. The increase in concentration was considered to have originated from the temporary change in the current in the room, owing to the procession of ventilation in the living room, despite the absence of ventilation in the room, which affected the gaseous radon concentration. Although both Cases 1 and 7 exhibited high reduction rates, the lowest radon concentration appeared after 3 and 4 h in the living room and room of Case 1, and after 5 and 4 h in the living room and room of Case 7, respectively. This indicates that although the radon concentration in the living room can be controlled by ventilation in the room, it is more suitable to ventilate all spaces of the entire household for effective indoor radon control in a short time.
The investigation of the ventilation scenarios in the room indicated that Cases 1, 4, and 7, which were directly ventilated, all exhibited reduction efficiencies of 90% or above, at 93.37%, 90.42%, and 93.13%, respectively, while Cases 3, 5, and 6, which were affected by indirect ventilation in the living room through closed windows and doors and gaps in the doors, exhibited relatively low reduction efficiencies of 60% or below. The reduction of radon concentration in the room up to a certain level indicates that radon was reduced by indirect ventilation effects, even if the room door and window were closed; however, the reduction rate at 60% or below implies that effective indoor radon management could not be achieved without direct ventilation. In addition, in the three scenarios, the orders of the scenarios that exhibited high reduction rates in the living room did not match the order of the reduction rates in the room, thereby suggesting that the radon reduction in the unventilated room was more influenced by atmospheric pressure and other factors than the radon reduction effect in the living room. Therefore, it was considered that direct ventilation is more efficient for reliable reduction effects in the room with ventilation by opening the room windows or doors connected to the outside and living room, even though the room could be affected by the natural ventilation of the living room.
In the room under the high mechanical ventilation condition, the Cr value was 1.19 for 1 h after the start of ventilation. The radon concentration increased and was followed by a gradual decrease, which was considered to have originated from a strong current change after mechanical ventilation, as radon was in a gaseous state. In the high mechanical ventilation condition, the reduction rate was higher in the living room than in the room, while in the middle and low mechanical ventilation conditions the rate was higher in the room than in the living room. The indoor radon concentration reduction was most effective at 54.70% with “high” mechanical ventilation in the living room; however, the reduction rate was 50% or below when operating under middle and low mechanical ventilation conditions. Proceeding ventilation with an intensity of high mechanical ventilation or above or mechanical ventilation in parallel with natural ventilation was considered efficient in predicting the radon reduction effect in the living room from mechanical ventilation alone. Meanwhile, the indoor radon concentration reduction with mechanical ventilation in the room was most efficient at 65.66% with the low mechanical ventilation, and a relatively high reduction efficiency was also observed from the middle mechanical ventilation at 59.16%. However, a reduction rate lower than 50% was observed from the high mechanical ventilation, thereby indicating that the low mechanical ventilation intensity is more effective than high intensity for radon management in narrow spaces. Therefore, it was determined that low mechanical ventilation intensity in narrow spaces and high mechanical ventilation intensity in wide spaces were effective for radon reduction.
In this study, based on various natural and mechanical ventilation conditions by the intensity of operation, various ventilation effects on radon in the indoor environment of an apartment housing, the most common type of residence in South Korea, were evaluated. Basic research was conducted to establish indoor ventilation guidelines via this evaluation. In addition, the study proceeded in an actual living environment with the condition of having residents, which was considered to sufficiently contribute to radon studies previously believed to have uncertainties regarding the influence of various environmental parameters.
5. Conclusions
In this study, basic research was conducted to develop guidelines for radon ventilation by evaluating various ventilation effects of indoor radon in apartment housings under various natural and mechanical ventilation conditions with different operational intensities. Accordingly, seven natural ventilation scenarios and three different mechanical ventilation operating conditions were investigated to compare and evaluate the radon reduction effects according to the ventilation operations per hour, with windows and doors that could be naturally ventilated, living room and room with natural ventilation, and mechanical ventilation system equipment as targets using the RAD 7 Radon Detector (Durridge Co., Billerica, MA, USA).
The results obtained from this study indicated that even in households on the upper floors of an apartment building, radon can accumulate at concentrations above the standard value in the absence of ventilation. Hence, appropriate radon management via ventilation is required.
Operating the natural ventilation system equipment can support the redistribution of the indoor air in an apartment house; however, controlling the indoor radon concentration by ventilation was challenging when the system was solely adopted. Opening all the windows was verified to provide reliable radon reduction in a short time, and bidirectional ventilation was determined to be more effective than unidirectional ventilation. Although sealed conditions can be affected by external ventilation, the reduction rate was 60% or below. Therefore, it was verified that, in general, partial ventilation was significantly more effective for indoor radon management.
Radon reduction by mechanical ventilation with a relatively low operational intensity was more effective in small spaces, while that with a relatively high intensity of mechanical ventilation was more effective in large spaces. Therefore, it is considered necessary to ventilate with a mechanical ventilation intensity that matches the properties of the space or a ventilation system that combines natural and mechanical ventilation to predict the radon reduction effect of mechanical ventilation alone.