Study on the Seismic Performance of Prefabricated Single-Segment Steel Jacket Bridge Piers
Abstract
:1. Introduction
2. Shaking Table Test
2.1. Similarity Relationship
2.2. Model Fabrication and Measuring Point Arrangement
2.3. Seismic Wave Selection and Load Condition
3. Seismic Response Analysis and Finite Element Simulation Comparison
3.1. Establishment of OpenSees Finite Element Model
3.2. Recurrence of Seismic Waves
3.3. Natural Frequency
3.4. Acceleration Response
3.5. Displacement Response
3.6. Concrete Strain
3.7. Reinforcement Strain
4. Discussion
5. Analysis of Various Parameters of the Prefabricated Bridge Piers
5.1. Influence of the Pier Top Counterweight on the Prefabricated Piers
5.2. The Influence of the Anchorage Length on the Prefabricated Bridge Piers
5.3. The Influence of the Thickness of the Steel Jacket
6. Conclusions
- (1)
- The natural frequencies of the two steel jacket prefabricated piers were greater than that of the CIP pier, and the steel jacket prefabricated piers had a higher stiffness than the CIP pier. The acceleration response, displacement response, strain response, and other seismic performance indicators of the two steel jacket prefabricated piers were less than those of the CIP pier; thus, the single-segment steel jacket prefabricated piers has better seismic performance than the CIP pier.
- (2)
- The dynamic responses of the two prefabricated piers were similar under the same ground motion, indicating that the seismic performance of the prefabricated piers with steel jackets was not affected by changing the anchorage length of the reinforcement in the grouting sleeve. Moreover, the steel jacket has a good effect of increasing stiffness, decreasing strain, and limiting displacement. Therefore, the ductility of the pier is significantly improved. Compared with the same group of tests, the steel jacket prefabricated single-segment bridge pier connected by a grouting sleeve has better seismic performance.
- (3)
- According to the OpenSees finite element parameter analysis, the pier top counterweight was found to have the greatest influence on the seismic performance of the prefabricated piers. With the increase of the PGA, the pier top counterweight that could be borne by the prefabricated piers was found to gradually decrease, and the maximum lateral resistance increased. Changing the anchorage length of the grouting sleeve within a certain range was found to have little effect on the seismic performance, and the anchorage length can be more than twice the minimum anchorage length specified in the current codes. Moreover, the thickness of the steel jacket should not be too thin or too thick, and the optimal thickness was found to be 5–7 mm.
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Tazarv, M.; Saiidi, M.S. UHPC-filled duct connections for accelerated bridge construction of RC columns in high seismic zones. Eng. Struct. 2015, 99, 413–422. [Google Scholar] [CrossRef]
- Roh, H.; Reinhorn, A. Hysteretic behavior of precast segmental bridge piers with, superelastic shape memory alloy bars. Eng. Struct. 2010, 32, 3394–3403. [Google Scholar] [CrossRef]
- Ameli, M.J.; Parks, J.E.; Brown, D.N.; Pantelides, C.P. Seismic evaluation of grouted splice sleeve connections for reinforced precast concrete column-to-cap beam joints in accelerated bridge construction. PCI J. 2015, 60, 80–103. [Google Scholar] [CrossRef]
- Ou, Y.; Wang, P.; Tsai, M.; Chang, K.; Lee, G. Large-scale experimental study of precast segmental unbonded posttensioned concrete bridge columns for seismic regions. J. Struct. Eng. 2010, 136, 255–264. [Google Scholar] [CrossRef]
- Parks, J.E.; Brown, D.N.; Ameli, M.J.; Pantelides, C.P. Seismic Repair of Severely Damaged Precast Reinforced Concrete Bridge Columns Connected with Grouted Splice Sleeves. ACI Struct. J. 2016, 113, 615–626. [Google Scholar] [CrossRef] [Green Version]
- Tazarv, M.; Saiidi, M. Low-damage precast columns for accelerated bridge, construction in high seismic zones. J. Bridge Eng. 2016, 21, 13. [Google Scholar] [CrossRef]
- Ameli, M.J.; Brown, D.N.; Parks, J.E.; Pantelides, C.P. Seismic Column-to-Footing Connections Using Grouted Splice Sleeves. ACI Struct. J. 2016, 113, 1021–1030. [Google Scholar] [CrossRef]
- Burak, R.; Seraderian, R. Accelerated bridge construction—On the fast track to success. In Proceedings of the Annual Conference of the Transportation Association of Canada, Halifax, NS, Canada, 26–29 September 2010. [Google Scholar]
- Wu, T.; Jiang, K. Experimental study on partially steel tube-confined RC column. Build. Struct. 2012, 42, 742–745. [Google Scholar]
- Liu, Y.; Zhou, B.; Cai, J.; Lee, D.S.H.; Deng, X.; Feng, J. Experimental study on seismic behavior of precast concrete column with grouted sleeve connections considering ratios of longitudinal reinforcement and stirrups. Bull. Earthq. Eng. 2018, 16, 6077–6104. [Google Scholar] [CrossRef]
- Deng, J.; Zong, Z. Anti-seismic properties of damaged concrete bridge piers with hollow cross-section strengthened with adhering steel plates II: Numerical analysis on seismic dynamic responses. J. Southeast Univ. (Nat. Sci. Ed.) 2013, 43, 1280–1287. [Google Scholar]
- Ding, M. Research on Seismic Retrofit Methods for Railway Bridge with Gravity Piers. Chin. J. Rock Mech. Eng. 2013, 43, 1280–1287. [Google Scholar]
- Fan, P.P. Dynamic Performance Study of Strengthening Reinforced Concrete Column with Steel. Master’s Thesis, Xi’an University of Science and Technology, Xi’an, China, 2008. [Google Scholar]
- Huang, H.; Zhang, W. Comparison and analysis of seismic reinforcement methods for circular reinforced con-crete bridge piers. World Earthq. Eng. 2020, 36, 163–171. [Google Scholar]
- Huang, H.; Zhang, W. Numerical analysis of seismic performance for circular RC bridge piers reinforced with circular steel tubes based on opensees. Earthq. Resist. Eng. Retrofit. 2020, 42, 113–120. [Google Scholar]
- Wang, R.; Ma, B.; Chen, X. Seismic performance of pre-fabricated segmental bridge piers with grouted splice sleeve connec-tions. Eng. Struct. 2021, 229, 111668. [Google Scholar] [CrossRef]
- Hewes, J.T. Seismic Design and Performance of Precast Concrete Segmental Bridge Columns. Ph.D. Thesis, University of California, San Diego, CA, USA, 2002. [Google Scholar]
- Olmos, B.; Jara, J.M.; Gómez, G. Influence of steel jacket thickness on the RC bridges’ seismic vulnerability. J. Traffic Transp. Eng. (Engl. Ed.) 2019, 6, 15–34. [Google Scholar] [CrossRef]
- Dan, Z.A.; Ning, L.; Zxlab, C.; Lx, A. Rapid repair of rc bridge columns with prestressed stainless-steel hoops and stainless-steel jackets—Sciencedirect. J. Constr. Steel Res. 2020, 177, 106441. [Google Scholar]
- Chou, C.; Chen, Y. Cyclic tests of post-tensioned precast CFT segmental bridge columns with unbonded strands. Earthq. Eng. Struct. Dyn. 2010, 35, 159–175. [Google Scholar] [CrossRef]
- Ameli, M.J.; Pantelides, C.P. Seismic Analysis of Precast Concrete Bridge Columns Connected with Grouted Splice Sleeve Connectors. J. Struct. Eng. 2016, 143, 1–13. [Google Scholar] [CrossRef]
- Zipeng, G.; Guangtao, X. Shaking table test study on grouting sleeve connecting assembled concrete pier. Earthq. Resist. Eng. Retrofit. 2020, 42, 84–90. [Google Scholar]
- Apostolopoulos, C.; Drakakaki, A.; Basdeki, M. Seismic assessment of RC column under seismic loads. Int. J. Struct. Integr. 2019, 10, 41–54. [Google Scholar] [CrossRef]
- Gu, S.K. Performance Analysis of Reinforced Concrete Hollow Pier Based on Dynamic Test. Master’s Thesis, Hebei University of Engineering, Handan, China, 2018. [Google Scholar]
- Xu, J.M.; Yan, M.J.; Liang, D.W. Shaking table test on single segment prefabricated concrete bridge pier connected by grouting sleeve. Int. J. Struct. Integr. 2021, 1757–9864. [Google Scholar] [CrossRef]
- Zhang, M. Study on similitude laws for shaking table tests. Earthq. Eng. Eng. Dyn. 1997, 2, 52–58. [Google Scholar]
- Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Technical Specification for Application of Steel Sleeve Grouting Connection(JTJ355-2015); China Architecture & Building Press: Beijing, China, 2015. [Google Scholar]
- Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Code for Seismic Design of Build-ings(GB50011-2010); China Architecture & Building Press: Beijing, China, 2010. [Google Scholar]
- Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Code for Seismic Design of Highways and Bridges (JTG/T2231-2020); China Architecture & Building Press: Beijing, China, 2010. [Google Scholar]
- Mander, J.; Priestley, M. Theoretical Stress-Strain Model for Confined Concrete. J. Struct. Eng. 1988, 114, 1804–1826. [Google Scholar] [CrossRef] [Green Version]
- Scott, B.; Park, R.; Priestley, M. Stress-strain behavior of concrete confined by overlapping hoops at low and high strain rates. J. Proc. 1982, 79, 13–27. [Google Scholar]
Physical Quantity | Similarity Relation | Similarity Coefficient |
---|---|---|
Length | 0.25 | |
Area | 0.0625 | |
Elastic modulus | 0.689 | |
Equivalent density | 1.409 | |
Acceleration | 1.957 | |
Mass | 0.022 | |
Time | 0.358 | |
Velocity | 0.699 | |
Frequency | 2.798 | |
Stress | 0.689 | |
Strain | 1 |
Loading Condition | Seismic Wave | X-Direction (g) | Y-Direction (g) | Loading Condition | Seismic Wave | X-Direction (g) | Y-Direction (g) |
---|---|---|---|---|---|---|---|
1 | EL-Centro | 0.137 | 0.116 | 5 | EL–Centro | 0.55 | 0.47 |
Taft 111 | Taft 111 | ||||||
Taft111/Taft21 | 0.137 | 0.121 | Taft111/Taft21 | 0.55 | 0.485 | ||
2 | EL–Centro | 0.274 | 0.233 | 6 | EL–Centro | 0.65 | 0.55 |
Taft 111 | Taft 111 | ||||||
Taft111/Taft21 | 0.274 | 0.241 | Taft111/Taft21 | 0.65 | 0.573 | ||
3 | EL–Centro | 0.391 | 0.332 | 7 | EL–Centro | 0.783 | 0.666 |
Taft 111 | Taft 111 | ||||||
Taft111/Taft21 | 0.391 | 0.345 | Taft111/Taft21 | 0.783 | 0.69 | ||
4 | EL–Centro | 0.431 | 0.366 | 8 | EL–Centro | 0.9 | 0.77 |
Taft 111 | Taft 111 | ||||||
Taft111/Taft21 | 0.431 | 0.38 | Taft111/Taft21 | 0.9 | 0.793 |
SJ1 (HZ) | SJ2 (HZ) | CIP (HZ) | SJ1 Simulation (HZ) | SJ2 Simulation (HZ) | |
---|---|---|---|---|---|
Initial frequency | 13.66 | 13.86 | 9.59 | 12.06 | 12.05 |
0.137 g | 13.41 | 12.33 | 9.03 | 11.89 | 11.87 |
0.274 g | 12.54 | 12.46 | 8.81 | 11.74 | 11.73 |
0.391 g | 12.68 | 12.5 | 8.44 | 11.53 | 11.51 |
0.431 g | 12.42 | 12.08 | 8.25 | 11.47 | 11.45 |
0.55 g | 11.23 | 10.94 | 8.18 | 11.21 | 11.2 |
0.65 g | 10.86 | 10.76 | 7.47 | 11.09 | 11.08 |
0.783 g | 10.84 | 10.78 | 7.27 | 10.78 | 10.76 |
0.9 g | 10.34 | 10.21 | 6.89 | 10.55 | 10.53 |
Decrease rate/% | 24.3 | 26.33 | 28.46 | 12.5 | 12.47 |
EL–Centro | Taft111 | Taft111/Taft21 | |||||||
---|---|---|---|---|---|---|---|---|---|
PGA/g | 0.274 | 0.55 | 0.783 | 0.274 | 0.55 | 0.783 | 0.274 | 0.55 | 0.783 |
i | 0.50 | 0.47 | 0.46 | 0.60 | 0.54 | 0.57 | 0.49 | 0.56 | 0.53 |
EL–Centro | Taft111 | Taft111/Taft21 | |||||||
---|---|---|---|---|---|---|---|---|---|
PGA/g | 0.274 | 0.55 | 0.783 | 0.274 | 0.55 | 0.783 | 0.274 | 0.55 | 0.783 |
i | 0.65 | 0.46 | 0.44 | 0.60 | 0.52 | 0.57 | 0.51 | 0.54 | 0.48 |
Anchorage Length | 6D | 8D | 10D | 12D | 14D |
---|---|---|---|---|---|
relative peak displacement | 2.49095 | 2.48833 | 2.48569 | 2.48327 | 2.48084 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Deng, B.; Jia, Y.; Liang, D. Study on the Seismic Performance of Prefabricated Single-Segment Steel Jacket Bridge Piers. Symmetry 2021, 13, 2312. https://doi.org/10.3390/sym13122312
Deng B, Jia Y, Liang D. Study on the Seismic Performance of Prefabricated Single-Segment Steel Jacket Bridge Piers. Symmetry. 2021; 13(12):2312. https://doi.org/10.3390/sym13122312
Chicago/Turabian StyleDeng, Baodong, Yanmin Jia, and Dongwei Liang. 2021. "Study on the Seismic Performance of Prefabricated Single-Segment Steel Jacket Bridge Piers" Symmetry 13, no. 12: 2312. https://doi.org/10.3390/sym13122312
APA StyleDeng, B., Jia, Y., & Liang, D. (2021). Study on the Seismic Performance of Prefabricated Single-Segment Steel Jacket Bridge Piers. Symmetry, 13(12), 2312. https://doi.org/10.3390/sym13122312