Author Contributions
Conceptualization, M.H. and X.Y.; software, X.Y. and J.L.; validation, X.Y.; formal analysis, X.Y.; investigation, X.Y.; data curation, X.Y., J.L. and Z.T.; writing—original draft preparation, X.Y.; writing—review and editing, X.Y. and M.H.; supervision, M.H.; project administration, M.H. and Z.T.; funding acquisition, M.H. All authors have read and agreed to the published version of the manuscript.
Figure 1.
Research ideas.
Figure 1.
Research ideas.
Figure 2.
Strata section of No. 1 vertical shaft.
Figure 2.
Strata section of No. 1 vertical shaft.
Figure 3.
No. 1 vertical auxiliary shaft flooded. (a) Water inrush; (b) Gushing water; (c) Flooded shaft.
Figure 3.
No. 1 vertical auxiliary shaft flooded. (a) Water inrush; (b) Gushing water; (c) Flooded shaft.
Figure 4.
Pictures of weakly and strongly weathered granite. (a) Weakly; (b) Weakly; (c) Strongly; (d) Strongly.
Figure 4.
Pictures of weakly and strongly weathered granite. (a) Weakly; (b) Weakly; (c) Strongly; (d) Strongly.
Figure 5.
Geological and hydrological conditions of No. 1 vertical auxiliary shaft.
Figure 5.
Geological and hydrological conditions of No. 1 vertical auxiliary shaft.
Figure 6.
Monitoring section position and lining type.
Figure 6.
Monitoring section position and lining type.
Figure 7.
Layout of measuring points and piezometers.
Figure 7.
Layout of measuring points and piezometers.
Figure 8.
Monitoring results of water pressure outside the lining at S1ZK0 + 660 m and S1ZK0 + 735 m of the No. 1 vertical auxiliary shaft [
36]. (
a) S1ZK0 + 660 m; (
b) S1ZK0 + 660 m.
Figure 8.
Monitoring results of water pressure outside the lining at S1ZK0 + 660 m and S1ZK0 + 735 m of the No. 1 vertical auxiliary shaft [
36]. (
a) S1ZK0 + 660 m; (
b) S1ZK0 + 660 m.
Figure 9.
On-site fissures reveal pictures. (a) On-site fracture picture 1; (b) On-site fracture picture 2.
Figure 9.
On-site fissures reveal pictures. (a) On-site fracture picture 1; (b) On-site fracture picture 2.
Figure 10.
On-site construction cracks revealed. (a) On-site fracture picture 1; (b) On-site fracture picture 2.
Figure 10.
On-site construction cracks revealed. (a) On-site fracture picture 1; (b) On-site fracture picture 2.
Figure 11.
Rock mass samples revealed by on-site drilling. (a) 643.40 m–654.70 m; (b) 654.70 m–666.80 m; (c) 666.80 m–678.70 m; (d) 713.30 m–724.50 m; (e) 724.50 m–735.70 m; (f) 735.70 m–747.50 m.
Figure 11.
Rock mass samples revealed by on-site drilling. (a) 643.40 m–654.70 m; (b) 654.70 m–666.80 m; (c) 666.80 m–678.70 m; (d) 713.30 m–724.50 m; (e) 724.50 m–735.70 m; (f) 735.70 m–747.50 m.
Figure 12.
Establishment of discrete fracture network of two sections. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 12.
Establishment of discrete fracture network of two sections. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 13.
Dual-medium model diagram of two sections. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 13.
Dual-medium model diagram of two sections. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 14.
Simulation of pore water pressure changes at measuring points. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 14.
Simulation of pore water pressure changes at measuring points. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 15.
Comparison of simulation results with monitoring results. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 15.
Comparison of simulation results with monitoring results. (a) S1ZK0 + 660 m; (b) S1ZK0 + 735 m.
Figure 16.
Description of the principle of water pressure characteristics.
Figure 16.
Description of the principle of water pressure characteristics.
Figure 17.
Method 2 numerical model diagram.
Figure 17.
Method 2 numerical model diagram.
Figure 18.
S1ZK0 + 660 m section MIDAS-GTS load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 18.
S1ZK0 + 660 m section MIDAS-GTS load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 19.
S1ZK0 + 735 m section MIDAS-GTS load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 19.
S1ZK0 + 735 m section MIDAS-GTS load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 20.
S1ZK0 + 660 m section RFPA load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 20.
S1ZK0 + 660 m section RFPA load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 21.
S1ZK0 + 735 m section RFPA load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 21.
S1ZK0 + 735 m section RFPA load loading plan. (a) Uniform pressure; (b) Non-uniform pressure.
Figure 22.
Simulated internal force of S1ZK0 + 660 m section. (a) Non-uniform axial force diagram; (b) Non-uniform bending moment diagram; (c) Uniform axial force diagram; (d) Uniform bending moment diagram.
Figure 22.
Simulated internal force of S1ZK0 + 660 m section. (a) Non-uniform axial force diagram; (b) Non-uniform bending moment diagram; (c) Uniform axial force diagram; (d) Uniform bending moment diagram.
Figure 23.
S1ZK0 + 660 m lining damage diagram. (a) Uniform pressure (step 15-2); (b) Non-uniform pressure (step 18-1).
Figure 23.
S1ZK0 + 660 m lining damage diagram. (a) Uniform pressure (step 15-2); (b) Non-uniform pressure (step 18-1).
Figure 24.
Simulated internal force of S1ZK0 + 735 m section. (a) Non-uniform axial force diagram; (b) Non-uniform bending moment diagram; (c) Uniform axial force diagram; (d) Uniform bending moment diagram.
Figure 24.
Simulated internal force of S1ZK0 + 735 m section. (a) Non-uniform axial force diagram; (b) Non-uniform bending moment diagram; (c) Uniform axial force diagram; (d) Uniform bending moment diagram.
Figure 25.
S1ZK0 + 660 m lining damage diagram. (a) Uniform pressure (step 11-2); (b) Non-uniform pressure (step 13-1).
Figure 25.
S1ZK0 + 660 m lining damage diagram. (a) Uniform pressure (step 11-2); (b) Non-uniform pressure (step 13-1).
Table 1.
Model geological parameters.
Table 1.
Model geological parameters.
Position | Elastic Modulus (MPa) | Poisson Ratio | Cohesion (MPa) | Internal Friction Angle (°) | Tensile Strength (MPa) | Density (g/m3) | Hydraulic Conductivity (m/s) | Porosity |
---|
S1ZK0 + 660 | 30,000 | 0.23 | 20.00 | 52.00 | 26.00 | 2.66 × 10−6 | 8.60 × 10−9 | 0.3 |
S1ZK0 + 735 | 30,000 | 0.23 | 20.00 | 52.00 | 26.00 | 2.66 × 10−6 | 8.60 × 10−9 | 0.3 |
Table 2.
Field revealed fracture group parameters.
Table 2.
Field revealed fracture group parameters.
Fissure Group | Center Point | Trend | Angle of Dip (°) | Fracture Length (m) | Density (one/×103 m2) |
---|
Uniform Distribution | Gaussian Distribution | Gaussian Distribution | Gaussian Distribution |
---|
1 | / | N60° E | / | 8 | 7 |
2 | / | N39° W | / | 5 | 7 |
3 | / | N12° E | / | 3 | 7 |
Table 3.
Field grouting parameters.
Table 3.
Field grouting parameters.
Grouting Section (m) | Slurry Material | Grouting Thickness (m) | Diffusion (m) | Effective Thickness (m) | Grouting Cycle Length (m) | Excavation (m) | Remaining Thickness of Safety Disk (m) |
---|
S1FK0+649.1~+774.74 | Modified urea-formaldehyde resin | 5 | 2 | 6 | 60 | 40 | 20 |
Table 4.
S1ZK0 + 660 m section lining safety factor calculation value, according to Method 1.
Table 4.
S1ZK0 + 660 m section lining safety factor calculation value, according to Method 1.
| Non-Uniform | Uniform |
---|
Bending moment (kN·m) | 257.4 | 41.2 |
Axial force (kN) | 7198 | 6775 |
Calculate the safety factor | 1.9 | 2.1 |
Specified safety factor | 1.1 | 1.35 |
Table 5.
S1ZK0 + 660 m section lining safety factor calculation value, according to Method 2.
Table 5.
S1ZK0 + 660 m section lining safety factor calculation value, according to Method 2.
| Non-Uniform | Uniform |
---|
Actual load (MPa) | 2.093 | 2.034 |
Normal service limit state load (MPa) | 3.593 | 3.834 |
Calculate the safety factor | 1.72 | 1.88 |
Specified safety factor | 1.1 | 1.35 |
Table 6.
S1ZK0 + 735 m section lining safety factor calculation value, according to Method 1.
Table 6.
S1ZK0 + 735 m section lining safety factor calculation value, according to Method 1.
| Non-Uniform | Uniform |
---|
Bending moment (kN·m) | 439.7 | 57.2 |
Axial force (kN) | 8717 | 9125 |
Calculate the safety factor | 1.6 | 2.0 |
Specified safety factor | 1.1 | 1.35 |
Table 7.
S1ZK0 + 735 m section lining safety factor calculation value, according to Method 2.
Table 7.
S1ZK0 + 735 m section lining safety factor calculation value, according to Method 2.
| Non-Uniform | Uniform |
---|
Actual load (MPa) | 2.53 | 2.57 |
Normal service limit state load (MPa) | 3.63 | 3.87 |
Calculate the safety factor | 1.43 | 1.51 |
Specified safety factor | 1.1 | 1.35 |
Table 8.
Comparison of the calculation results of the two methods.
Table 8.
Comparison of the calculation results of the two methods.
Location | Load Plan | Method 1 | Method 2 | Specified Safety Factor | Error Compared to Method 1 |
---|
S1ZK0 + 660 m | Uniform pressure | 2.1 | 1.88 | 1.35 | −10.5% |
Non-uniform pressure | 1.9 | 1.72 | 1.1 | −9.5% |
S1ZK0 + 735 m | Uniform pressure | 2.0 | 1.51 | 1.35 | −24.5% |
Non-uniform pressure | 1.6 | 1.43 | 1.1 | −10.6% |