1. Introduction
Sound propagation through the air is attenuated by atmospheric absorption, mainly due to relaxation vibrations of the oxygen and nitrogen molecules. The air attenuation is negligible at low frequencies but increases rapidly with frequencies above 1 kHz. The molar concentration of water vapor influences the atmospheric absorption, acting as a catalyst for the relaxation of oxygen and nitrogen (Annex A) [
1]. Thus, the absorption is lower in humid air than in dry air. In practice, the atmospheric conditions are characterized by the temperature and the relative humidity (RH) as a percentage. If the absolute humidity is kept constant, an increase in the temperature leads to decreasing RH, and vice versa. For example, the atmospheric absorption is approximately the same at (18 °C, 55% RH), (20 °C, 50% RH), or (22 °C, 45% RH).
The measurement of reverberation time and other room acoustic parameters is described in the International Standard ISO 3382-1 [
2]. All room acoustic measurements according to this standard are made in octave bands. The measurement results can vary with the air temperature and the relative humidity, and, consequently, the standard requires that these atmospheric data should be measured and included in the measurement report. It is realized that in cases with very different atmospheric conditions, the measured acoustic results may not be comparable. This is not a satisfactory situation, and Harris suggested the following in 1966 [
3]:
“In presenting reverberation-time data for large auditoriums, irrespective of the humidity and temperature at which measurements are made, correct the reverberation time so that it represents the reverberation time that would have been obtained if the measurements had been made at a relative humidity of 50% and a temperature of 20 °C, i.e., standard conditions”.
The correction method presented by Harris is relatively simple and uses the air attenuation coefficients at the center frequency of the octave bands below 2000 Hz and those of the one-third octave bands from 2000 Hz to 12,500 Hz. The reverberation time is converted to the decay rate in dB per second, and the correction for air absorption is made with the assumption of ideal exponential decays. The attenuation coefficients are those valid for pure tones at the center frequency of the applied frequency band, either octave or one-third octave. The method works well for measurements in one-third octave bands, but for field measurements in octave bands, the method is not accurate for long reverberation times and high frequencies, as will be explained later. There is no evidence of a general application of the method in practice.
Since the bandwidth used for the measurements is important for the problem of air attenuation, it should be noted that octave bands have not always been preferred for room acoustic measurements. The first edition of ISO 3382 [
4] from 1975 prescribes one-third octave bands from 125 Hz to 4000 Hz, i.e., the same as used for the measurement of the sound-absorbing properties of materials in a reverberation chamber. However, at least since the 1960s, it has been common practice to perform reverberation time measurements in concert halls in octave bands. Thus, in 1997, the second edition of ISO 3382 [
5] was established, stating that reverberation time in concert halls should be measured in octave bands, while one-third octave bands can be used in other kinds of rooms.
In a book by Cremer and Müller, there is a reference to a simple approximate formula to estimate the attenuation coefficient directly from the frequency and the relative humidity [
6] (Equation (1,45 a)). The formula can be expressed in terms of the energy attenuation coefficient m in reciprocal meters:
where
f is the frequency in kHz and
φ is the relative humidity in %. The approximation is based on experimental data between 30% and 80% relative humidity and limited to a fixed air temperature of 20 °C. Nothing is said about the bandwidth of the measurements. Obviously, the attenuation is assumed to be a simple linear function of the frequency, which is not true for measurements in octave bands but can be an acceptable approximation for one-third octave bands. Again, there is no evidence of a general application of the method in practice.
A very precise analysis of the problem with air absorption and octave bands was presented by Sutherland and Bass [
7]. They describe how the air absorption shapes the spectrum such that, after some time of propagation, most of the energy is in the lower part of the band. A numerical calculation method is presented, where the octave band is divided into a number of constant percentage filter elements. It is suggested that the number of filter elements must be at least 12 for an integration error less than 0.1 dB.
Sisler and Bass [
8] simulated the effect of one-third octave band filters used for reverberation time measurements. They found that the results will differ significantly from those of a pure tone with a frequency at the geometric center of the band. They mention that octave band filters would lead to even greater differences.
ISO 9613-1 [
1] is the reference for calculating the absorption of sound by the atmosphere. The energy attenuation coefficients calculated in accordance with the standard are provided in tables with the pure-tone attenuation coefficients at the exact center frequencies of one-third octaves from 50 Hz to 10 kHz, temperatures from −20 °C to +50 °C in 5 °C intervals, and relative humidity from 10% to 100% in 10% intervals. In addition, the exact formulas behind the calculations are provided. In the standard, it is stated that the exact midband frequency of an octave band can be used for an approximate calculation of the air attenuation of broadband sound in an octave band. This is applicable when the attenuation due to air absorption is not more than approximately 15 dB. The error is ≤±0.5 dB for
r∙(
fc)
2 ≤ 3 km (kHz)
2, where
r is the distance of sound propagation and
fc is the center frequency. The standard is intended for outdoor sound propagation, but there should be no problem in applications for sound propagation in rooms. In rooms with hard surfaces, the reverberation time may exceed 8 s at some frequencies. This means that, for room acoustical applications, the simple approximation using the center frequency may be valid below 1 kHz but not in octave bands above 1 kHz.
The American National Standard ANSI S1.26 [
9] has contents almost identical to ISO 9613-1 [
1]. However, an approximate method for fractional-octave bands is described in [
9] (Annex E). It is a non-linear function of the pure-tone attenuation at the midband frequency over the total distance of sound propagation. The approximate attenuation is calculated as the product of the pure-tone attenuation of the exact center frequency and a non-linear function or this pure-tone attenuation and the normalized filter bandwidth.
ISO 9613-2 [
10] is a standard describing calculation methods for outdoor sound propagation. In [
10] (Chapter 7.2), typical examples of attenuation coefficients for octave bands of noise in dB/km are presented. Ref. [
10] (Table 2) provides data for octave bands from 63 Hz to 8000 Hz. The data are the pure-tone attenuation coefficients of the octave band center frequencies. This implies, according to [
8] (8.1.3), that the data are not accurate for attenuations above 15 dB. In the 8 kHz band, the maximum distance of valid application is found to be between 74 m and 253 m in the examples in [
10] (Table 2). It is noted that these limitations of application are not mentioned in the standard.
The European Norm EN 12354-6 [
11] provides formulas for calculation of the reverberation time in a room from the total equivalent absorption area including the air absorption. A table is provided with energy attenuation coefficients in air in octave bands for selected examples of temperature and humidity. Below 1 kHz, these coefficients are the pure-tone attenuation coefficients of the center frequency of the octave band. For the 1 kHz to the 8 kHz octave bands, the coefficients are the pure-tone attenuation coefficients of the center frequency of the lower one-third octave within the octave band. This is assumed to handle the spectral change within the octave band during the sound propagation.
Extensive experiments in a 175 m
3 room with changeable temperature and relative humidity (RH) were reported by Wenmaekers et al. [
12]. The temperature varied in the range of 12 °C to 38 °C and the RH in the range of 15% to 80%. The average reverberation time of the room was 1.7 s. The octave band reverberation time
T20 was derived in ten octave bands with center frequencies from 31.5 Hz to 16 kHz. The statistical correlation between the measured reverberation time and the RH was analyzed. Good correlation was found for frequencies 1 kHz and 2 kHz when fitting to the pure-tone attenuation of the center frequency of the octave band. For frequencies of 4 kHz and higher, a good correlation was found when fitting to the pure-tone attenuation of the lower limiting frequency of the octave band. It is noted that the limiting frequency is called the edge frequency in [
12]. Using the attenuation of the lower edge frequency is called the edge frequency method, and it is suggested by the authors to overcome the problem of non-linear attenuation in octave bands.
A later study by Wenmaekers et al. [
13] deals with calculations of reverberation time in octave bands and the investigation of different methods, including the edge frequency method, to estimate the effect of air absorption. As a reference, calculations of decay curves with the summation of 96 frequencies within each octave band are utilized. This summation method is similar to that used by Sutherland and Bass [
6]. For high frequencies and reverberant spaces, it is recommended that air absorption in octave bands is calculated using the summation method, whereas for one-third octave bands, it is sufficiently accurate to use the pure-tone attenuation at the center frequency. It is also found that the reverberation time averaged over three one-third octave bands is not equal to the reverberation time derived from the full octave band containing those one-third octave bands. Finally, the study investigates the problem of measurement in acoustic scale models and how to adjust for excessive air absorption at very high frequencies.
Experimental data of room acoustical parameters measured under different thermo-hygrometric conditions were analyzed statistically by Tronchin [
14] and Granzotto et al. [
15]. The temperature varied between 27 and 32 °C and the relative humidity between 38 and 55% RH. The air velocity varied between 0 and 0.56 m/s due to fans in operation. It should be noted that the absolute humidity of the air was almost constant, and, thus, the relative humidity was directly linked to the temperature. This implies that the actual variation in air attenuation was very limited. The experimental results led the authors to claim that sound absorption due to air attenuation is not sensitive to variations in humidity. It was found that the room acoustic parameters most influenced by changes in temperature and humidity were
C80 and
T30, while the least influenced were
D50 and EDT. However, these findings are most likely due to variations in the speed of sound and not to variations in the air attenuation.
In room acoustic scale measurements, the problem of air attenuation is very significant, and different solutions have been applied to compensate for the very pronounced air attenuation at the measurement frequencies, which are ten-times higher than normal in a 1:10 scale model. It has been suggested to make corrections using the pure-tone attenuation at the octave band center frequency [
16] or using the pure-tone attenuation at the lower limiting frequency of the octave band [
12]. Both methods neglect the non-linear behavior of the air attenuation in octave bands. Another method is to perform the corrections in the frequency domain instead of the time domain [
17]. This requires Fourier transforms of time samples of the impulse response, and inverse Fourier transforms back to the time domain after the correction for air attenuation.
In the present article, the summation method for calculating the octave-band energy attenuation coefficient as a function of the time of propagation is presented in
Section 2. It is demonstrated that the attenuation is a non-linear function of time of propagation, and an approximation using a linearization is suggested in
Section 3. To overcome the problem of the temperature-dependent speed of sound, the method uses a transformation from the time domain to the distance domain.
Section 4 explains how a measured impulse response can be normalized to a standard atmosphere. As an alternative, a simple method for normalizing reverberation time measurements is also suggested. During the present work, the summation method was implemented in the ODEON room acoustics software version 18.11, which was used for postprocessing the measurements in
Section 5.
The purpose of the present article is to fill the gap between the well-established theoretical calculation model for pure-tone air attenuation and a practical approach to estimate the octave-band air attenuation in measured impulse responses.
2. The Summation Method
The energy attenuation coefficient is calculated in accordance with ISO 9613-1. The calculation method in the standard is valid for pure tones, and it is assumed to be the most accurate basis that is available. The air attenuation can be expressed either as the sound attenuation coefficient, α in decibels per meter or as the energy attenuation coefficient, m in reciprocal meters. In the following, the time t is relative to the arrival time of the direct sound at the receiver.
The attenuation due to air absorption of the sound pressure level of a pure tone with frequency
f after propagating the distance
r(
t) is given by:
where
δL(f, t) is the attenuation of the sound pressure level due to air absorption, in decibels
α(f) is the pure-tone sound attenuation coefficient, in decibels per meter
m(f) is the energy attenuation coefficient, in reciprocal meters
K = 10 lg(e) ≈ 4.343 dB is a constant
r(
t) is the distance that the sound wave has travelled at the time
t, in meters, calculated as
where
c is the speed of sound at the relevant temperature, meters per second
t is the time relative to the start of the arrival of the direct sound, in seconds
d is the distance from the sound source to the microphone, in meters.
The speed of sound in air
c is mainly a function of the atmospheric temperature. Although the speed of sound also changes a little with the humidity, up to 0.3% compared to dry air (Harris, 1971) [
18], this effect is here considered to be negligible ([
1] Paragraph A.6 and [
18] Figure 2). Thus, the speed of sound is calculated from [
1] Equation (A.5):
where
c0 = 343.2 m/s is the speed of sound at the reference temperature (20 °C)
T is the ambient atmospheric temperature, in °C
In room acoustic measurements, the impulse response is a function of the time t starting at the arrival of the direct sound. The distance d is not inherent in the measured impulse response, and this information must be provided by the user. Especially at frequencies well above 1 kHz, the air attenuation from source to receiver can be significant, and errors of several dBs may occur if the distance is not included. If this distance is not known, a default value of d = 10 m may apply.
The octave-band average energy attenuation coefficient changes according to how long the sound wave has travelled. The attenuation increases with frequency, and, thus, it varies within the bandwidth of an octave. This means that the higher frequencies within the octave are attenuated more than the lower frequencies, and during the sound propagation, the energy balance is shifted towards lower frequencies in the octave band. For this reason, the attenuation of sound in an octave band is not linear.
In the following, it is assumed that the frequency spectrum of the sound emitted from the source is flat (like pink noise) within the octave band. The octave-band average energy attenuation coefficient can be calculated from several frequencies equally distributed in a logarithmic scale within the octave band using Equation (5).
where
mB(t) is the energy attenuation coefficient of the octave band, in reciprocal meters
n is the number of frequencies used for the averaging within the octave band
m(fi) is the energy attenuation coefficient at the frequency fi, calculated in accordance with ISO 9613-1, in reciprocal meters
The calculation with Equation (5) can be made by dividing the octave band into several frequencies, each carrying the same energy at the time
t = 0. This summation method is like that used by Sutherland and Bass [
6], and it was used as a reference method by Wenmaekers et al. [
13]. Using
N = 9 is found to be sufficient for an accurate calculation. Tests were conducted with
N = 15 without any noticeable change in the results. The actual frequencies for
N = 9 are calculated by Equation (6).
where
n is the number of the octave band center frequency according to ANSI S1.6 [
19], (e.g.,
n = 30 for the 1000 Hz octave band),
i is a number {1; 9}.
The octave-band energy attenuation coefficient
mB is a function of temperature, relative humidity, and time of sound propagation. Two examples for the 4 kHz octave band are shown in
Figure 1 for temperatures of 0 °C and 20 °C, respectively. The attenuation is calculated for different times of sound propagation, 0.25 s, 1 s, 4 s and 8 s. The initial octave-band energy attenuation coefficient is seen to be close to the pure-tone energy attenuation coefficient of the center frequency of the octave band. However, for longer propagation times, the octave-band energy attenuation coefficient approaches asymptotically the pure-tone energy attenuation coefficient one-third octave below the center frequency of the octave band, i.e., the nominal frequency 3150 Hz in this case.
The behavior at 4 kHz seen in
Figure 1 is similar in other octave bands and at other air temperatures at least from −10 °C to 40 °C.
The time dependency of the octave-band energy attenuation coefficient
mB is more clearly seen when displayed as an attenuation of the sound pressure level in decibels as a function of time. Like Equation (2) for pure tones, the time-dependent octave-band attenuation of the sound pressure level (SPL) due to air absorption is given by Equation (7).
Examples of this relationship are calculated using Equation (5) and displayed in
Figure 2 for the four octave bands from 1 kHz to 8 kHz for the reference case of 20 °C and 50% RH. It is seen that the octave-band attenuation is not linear. For comparison, the linear pure-tone attenuation functions of the center frequency of the octave band and at the frequency one-third octave below the octave band center frequency are also shown. In the 8 kHz octave band, the energy attenuation coefficient reaches and goes below the pure-tone energy attenuation coefficient at 6.3 kHz nominal frequency after more than 2 s of propagation. However, the air attenuation at 8 kHz is more than 60 dB after 2 s of propagation, so the air attenuation at 6.3 kHz can be considered the asymptotic approximation in practice.
The results shown in
Figure 2 show that the pure-tone attenuation of the octave center frequency is a valid approximation for short times of propagation or, more precisely, up to attenuations around 15 dB. This confirms the information on the upper limit for the approximation given in ISO 9613-1 [
1]. It is also seen that the pure-tone attenuation at a frequency one-third octave below the octave center frequency is not a good approximation. However, this is the approximation used in the European norm for calculation of sound absorption in closed spaces, EN 12354-6 [
11]. It must be concluded that this method is not accurate.
Another suggested approximation for the octave-band attenuation is given as a non-linear formula in Annex E of ANSI S1.26 [
9]. This approximation has been implemented and compared to the octave band SPL attenuation calculated as a function of time of propagation with Equation (5) and
N = 9, see
Figure 3. The approximation yields attenuation that is systematically too low for longer times of propagation, and for the octave bands 2 kHz and 4 kHz, the attenuation decreases after reaching a maximum of around 18 dB. It must be concluded that this approximation cannot be used. Wenmaekers et al. [
13] also found that this approximation fails to estimate accurate decay curves for octave bands.
It appears that the problem of air absorption in octave bands is complicated, and none of the approximations found in the literature can offer a valid solution to this problem. The best solution is the summation method, but it is quite heavy in terms of calculations when applied to every single time step in the impulse response.
3. Approximation Using Linearization
It is necessary to realize that the air attenuation in octave bands is not a linear function of distance/time of propagation. Therefore, a linearization method is searched for. It is suggested to approximate the octave-band air attenuation by using the pure-tone attenuation of two different frequencies, one frequency f1 valid below a certain distance rk and another frequency f2 valid at longer distances.
The approximation has been tested for a wide range of temperatures and humidities, and the best results are obtained if
f1 is the exact center frequency of the octave band and
f2 is the center frequency of the lower one-third octave within the octave band, see
Table 1 and
Figure 4. The two pure-tone attenuation lines cross in a knee point, and the distance
rk to the knee point is as in Equation (3) with
t =
tk. From the information in ISO 9613-1 [
1] (8.1.3), it could be expected that the knee point is where the air attenuation is approximately 15 dB. A closer study has led to the criterion
δLk = 14 dB in the octave bands 1 kHz and above, and
δLk = 6 dB in the 500 Hz octave band. Below 500 Hz, a knee point is not relevant because the air attenuation is very small and nearly linear.
The distance of sound propagation to the knee point
rk is calculated by Equation (8a):
The corresponding time
tk of the knee point in the impulse response depends on the speed of sound
c and the distance
d from source to receiver. It is calculated by Equation (8b):
The approximation for the attenuation of the sound pressure level in an octave band due to the absorption in the air is calculated in the distance domain by Equation (9):
where
δLB(r) is the octave-band attenuation of the sound pressure level due to air absorption as function of the distance r, in decibels
m(f1) is the energy attenuation coefficient at the frequency f1, in reciprocal meters
m(f2) is the energy attenuation coefficient at the frequency f2, in reciprocal meters.
An example of the attenuation of the sound pressure level due to the absorption in the air is shown in
Figure 4 for the reference condition of 20 °C and 50% RH. The change of slope is seen when the attenuation exceeds 14 dB. The example in
Figure 4 could suggest a knee point lower than 14 dB to minimize the difference between the approximation and the summation method. However, after studying a wide range of temperature and humidity conditions, the choice of 14 dB is the best compromise.
A significant change of the air attenuation is seen when the results for different atmospheric conditions are compared in
Figure 5. Two quite different examples are shown. In the first example, the temperature is 0 °C, RH 20%, and the air attenuation is pronounced at 500 Hz and 1 kHz. The knee point of the approximation is reached at or before 3 s (
Figure 5a). The air attenuation at 500 Hz is high enough to show a non-linear behavior like that at higher frequencies, but the knee point for this frequency is at a lower value of attenuation,
δLk = 6 dB.
When the temperature is 20 °C and RH 80% (
Figure 5b), the non-linear attenuation is pronounced at 4 kHz and 8 kHz, but not so much at the lower frequencies.
5. Example Case
The reverberation time has been measured in the Oslo Opera auditorium several times during 2023. This opera house was completed in 2007, and the main auditorium has a maximum of 1364 seats. The width of the stage opening is 16 m. Particularly interesting in this context are the measurements made in February and in July, because the air humidity was quite different. In July, the conditions were very close to the standard atmosphere (20.0 °C, 52% RH), and normalization of the results would not change anything. But, in February, the relative humidity was much lower (20.6 °C, 31% RH), and the normalization led to a significant difference at high frequencies. A photo from the auditorium is seen in
Figure 9. The omni-directional sound source was just behind the orchestra pit and in front of the closed iron curtain. Microphone positions were in several places, and the one selected for this context was at the side on the second balcony, see
Figure 10. Source and microphone positions were the same on the two measurement days, and the distance from source to receiver was approximately 15 m. However, the conditions in the auditorium were not the same during the two measurements; the orchestra pit was open and furnished with chairs and music stands in February. In July, the floor of the orchestra pit was raised as an extension of the stage and not furnished. This can explain some minor differences in the results.
The results of the measured and normalized reverberation times
T20 and
T30 from 1 kHz to 8 kHz are presented in
Figure 11. The full summation method was applied. At 4 kHz and 8 kHz, there is a significant difference between the measurement results at 52% RH and 31% RH. The measurements at 52% RH are shown without normalization, because this would make no difference. The measured reverberation times are shorter when the air is dry, but using the normalization of the impulse response brings the results from different atmospheric conditions very close. At 8 kHz, a tendency to over-compensate for the air attenuation is noted, especially for the
T30 results. This will be discussed later in
Section 6.
The approximate normalization method has also been applied to these measurements, see
Table 3. The reverberation times measured at 31% RH were normalized to 50% RH, and the approximate method yields results that are nearly as good as the those obtained by normalization of the impulse response with the summation method. The relative deviation from the reference results obtained with 52% RH is given in
Table 4.
Concerning the EDT results, the summation method applied for the normalization provides good agreement with the reference measurements (up to ±5% deviation). But the approximation method does not work so well; the results are over-compensated from −15% deviation without correction to +29% with correction.
Looking at the results for T20, both methods provide good results (up to ±5% deviation). For the T30 results, the approximation method works fine in all octave bands, whereas the summation method over-compensates at 8 kHz (+10% deviation with correction).
The distances of sound propagation related to the approximation method are presented in
Table 5 for the octave bands 1 kHz to 8 kHz. It is noted that at 8 kHz, the distance to the knee point is shorter than
r3 and
r4, so
T20 and
T30 are both affected by the lower air attenuation beyond the knee point. At 4 kHz, this only yields
T30. At frequencies below 4 kHz, the distance to the knee point is far longer than any of the distances related to the reverberation parameters.
6. Discussion
The results from the case with measurements in the opera house point at some interesting issues, especially related to the 8 kHz octave band. The adjustment for normalization of measurements made in dry air, i.e., with very high air attenuation, tends to be too big, and this is best seen in the T30 results. It seems that the actual air attenuation in the measurement is less than the calculated air attenuation. This may be explained by the spectrum of the sound emitted by the sound source.
The sound source applied for the measurements is the Odeon Omni [
21], which covers a wide frequency range. However, within the 8 kHz octave band, the spectrum decreases towards the higher frequencies, approximately by 3 dB from lower to higher limiting frequency, see
Figure 12. This means that the measurements have more weight on the lower frequencies within the octave band, and, thus, the actual air attenuation is lower than assumed with the summation method calculations. If the default distance of 10 m is applied instead of the actual distance from source to receiver, a similar effect can be expected if the distance is very long, so the air attenuation has already shifted the spectrum before the direct sound reaches the receiver. The problem is exaggerated by the fact that the air attenuation is high at 8 kHz, and the correction is the difference between two big numbers, see the example in
Figure 6.
On this background, it is remarkable that the approximation method also yields good results at 8 kHz. Nevertheless, it seems like normalization of measurements in the 8 kHz octave band is not reliable. In principle, it might be possible to adapt the summation method to consider the actual spectrum generated by the sound source, but in practice, this is not realistic. The difficulties revealed for measurements in the 8 kHz are of particular relevance for measurements related to speech intelligibility [
22].
In a big room with a high ceiling, the temperature is not the same over the entire volume. Normally, the temperature is lower near the floor and higher under the ceiling. However, the methods described in this paper assume homogeneous atmospheric conditions. This means that a perfectly correct method for the normalization of acoustic measurements is not possible.
7. Conclusions
Reverberation time and other room acoustic parameters are influenced by air absorption, especially at frequencies above 1 kHz. For pure tones, the air absorption is a complicated but known function of the ambient temperature and relative humidity. However, room acoustic measurements are normally made in octave bands, and the air absorption of sound in octave bands is not a linear function of the distance of sound propagation. The air attenuation increases rapidly with increasing frequency, and it is very high in the 8 kHz octave band.
The summation method is known from the literature, and it is found to be a realistic possibility for correction of the impulse response, thus normalizing the room acoustic parameters derived from that. It is quite laborious but can provide accurate results. It assumes that the sound source has a flat spectrum within each octave band.
For the reverberation time measurements, an alternative approximate method is proposed. The attenuation as a function of distance can be approximated by two linear attenuation curves, meeting in a knee point. The knee point is defined as the distance of sound propagation where the pure-tone attenuation at the center frequency of the octave band reaches 14 dB at 1 kHz and higher frequencies. At longer distances after the knee point, the course of the air attenuation follows the pure-tone attenuation at a frequency one-third octave below the center frequency of the octave band.
Both for the summation method and the simplified linearization method, it should be noted that, in principle, the distance between the sound source and microphone should be known. Currently, it is not a part of the usual practice to report this distance, so this yields a minor complication in practical measurements. In most practical cases, it may be sufficiently accurate to apply a default distance of 10 m.
It is shown that with the summation method, it is possible to normalize room acoustic measurements to the air attenuation of a standard atmosphere, at least in octave bands up to 4 kHz. At 8 kHz, the results become less reliable because of the influence of a non-flat spectrum of the sound source.