Next Article in Journal
Evaluation of Finger Movement Impairment Level Recognition Method Based on Fugl-Meyer Assessment Using Surface EMG
Previous Article in Journal / Special Issue
CFD Study of the Impact of an Electrical Power Transformer on a Historical Building: Assessment and Solutions
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Triple Validation of Calibrated Building Energy Models with Different Air Infiltration Values

by
Gabriela Bastos Porsani
1,
Juan Bautista Echeverría Trueba
1 and
Carlos Fernández Bandera
2,*
1
School of Architecture, University of Navarra, 31009 Pamplona, Spain
2
School of Technology, Universidad de Extremadura, 10003 Cáceres, Spain
*
Author to whom correspondence should be addressed.
Appl. Sci. 2024, 14(23), 10828; https://doi.org/10.3390/app142310828
Submission received: 10 October 2024 / Revised: 14 November 2024 / Accepted: 21 November 2024 / Published: 22 November 2024
(This article belongs to the Special Issue Energy Efficiency and Thermal Comfort in Buildings)

Abstract

Model calibration refines design-stage inputs to align with real-world building performance. Accurate parameter selection, especially for highly sensitive variables like air leakage, is crucial. This study compared two building energy model calibration methods. The “classic” method adjusted indoor air capacitance, internal mass, and air infiltration, while a novel method focused on capacitance and internal mass, using empirical data for infiltration. The infiltration values were calculated using the decay equation and the EnergyPlus equations with site-specific coefficients. A triple validation assessed model performance in terms of temperature (CIBSE TM63), energy consumption (minimization), and indoor air quality (represented by CO2 levels in accordance with the ASTM D5157 Standard). Results demonstrated the novel method’s superiority across all three performance metrics. All calibrated models met the CIBSE TM63 criteria even during the validation period, which was five times longer than the training period. Compared to the classic method, models incorporating dynamic empirical infiltration showed a 29% and 26% improvement in MAE and RMSE, respectively, in temperature prediction. In energy consumption results, the novel method models presented a 31% reduction, and for CO2 level agreement, these models achieved a 130% higher R² value than the classic model. In addition, the classic method’s infiltration values failed to meet ASTM D5157 requirements, suggesting reliance on unrealistic parameter values for accurate temperature representation. The incorporation of calculated air leakage data into the BEM allowed a more realistic estimation of capacitance and internal mass values, emphasizing the importance of accurate air infiltration modeling for overall model reliability.
Keywords: model calibration; building energy model (BEM); infiltration modeling; decay method; model validation; energy efficiency model calibration; building energy model (BEM); infiltration modeling; decay method; model validation; energy efficiency

Share and Cite

MDPI and ACS Style

Bastos Porsani, G.; Echeverría Trueba, J.B.; Fernández Bandera, C. Triple Validation of Calibrated Building Energy Models with Different Air Infiltration Values. Appl. Sci. 2024, 14, 10828. https://doi.org/10.3390/app142310828

AMA Style

Bastos Porsani G, Echeverría Trueba JB, Fernández Bandera C. Triple Validation of Calibrated Building Energy Models with Different Air Infiltration Values. Applied Sciences. 2024; 14(23):10828. https://doi.org/10.3390/app142310828

Chicago/Turabian Style

Bastos Porsani, Gabriela, Juan Bautista Echeverría Trueba, and Carlos Fernández Bandera. 2024. "Triple Validation of Calibrated Building Energy Models with Different Air Infiltration Values" Applied Sciences 14, no. 23: 10828. https://doi.org/10.3390/app142310828

APA Style

Bastos Porsani, G., Echeverría Trueba, J. B., & Fernández Bandera, C. (2024). Triple Validation of Calibrated Building Energy Models with Different Air Infiltration Values. Applied Sciences, 14(23), 10828. https://doi.org/10.3390/app142310828

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Article metric data becomes available approximately 24 hours after publication online.
Back to TopTop