1. Introduction
Energy consumption has greatly contributed to the promotion of human development and progress. However, its waste emission brings more and more serious environmental pollution and ecological destruction simultaneously. Waste heat recovery and low-grade heat utilization are important measures to solve the problems brought by energy consumption. The organic Rankine cycle (ORC), which applies the principle of the steam Rankine cycle but uses organic working fluids with low boiling points, is a very promising technique used for waste heat recovery. The group of Lemort and Quoilin [
1] focused on both the thermodynamic and economic optimization of a small scale ORC in waste heat recovery application. The working fluids they considered include R245fa, R123, n-butane, n-pentane, R1234yf and Solkatherm. They also carried out experimental study using scroll expander and using R123 [
2] and R245fa [
3]. The group of Karellas conducted much research on ORC configuration optimization [
4,
5,
6] and experimental performance [
7]. The group of Brüggemann, Heberle, and Preißinger used isobutane/isopentane and R227ea/R245fa as working fluids in ORC for low-enthalpy geothermal resources [
8] and conducted a thermoeconomic analysis [
9]. They also carried out an experimental characterization and comparison of axial and cantilever micro-turbines for small-scale ORC [
10]. Many papers focus on internal combustion engine (ICE) waste heat recovery using ORC technique [
11,
12,
13,
14,
15,
16,
17]. Cycle configurations [
11,
12,
16,
17], fluids [
14,
15] and parameters optimization [
13,
14,
15] are usually discussed and analyzed in these papers. However, there are few reports on test bench or experimental system used for ICE waste heat recovery based on ORC technique.
Among the four devices making up an ORC, the expander is the critical component because it determines the efficiency and cost of an ORC. Expanders, in general, can be categorized into two types: the velocity type and the volume type. The popular axial turbine expanders belong to the former type while the latter type includes screw expanders, scroll expanders and reciprocal piston expanders [
18]. Yamada et al. [
19] developed a compact ORC system using a compact rotary-vane-type expander for low-temperature waste heat recovery. Approximately 30 W of expander power output with 48% expander efficiency was achieved. Kolasi’nski et al. [
20] conducted experimental and numerical analyses on the rotary vane expander in a micro ORC system. They indicated that a properly designed multi-vane expander is a cheap and mechanically simple alternative to other expansion devices proposed for domestic ORC systems [
21]. The group of Lemort and Quoilin [
2,
3] modified a scroll compressor to an expander and conducted experimental studies. Measured performance on the prototype is very promising in a wide range of operating conditions. The maximum shaft power is 2.1 kW and maximum achieved isentropic efficiency is 75.7% [
3]. Bao and Zhao [
22] carried out a detailed review on the expander used in ORC. They summarized the prototype research on various types of expansion machines. They also made a comparison of various types of expanders suitable for ORC system. According to the power capacity, radial-inflow turbine is maximum, which is suitable for the large capacity system. For volume type expander, screw and reciprocating piston expanders can also output relatively high power, which can be applied to small- and medium-sized systems. The capacity of scroll and rotary vane expander is minimum, generally applied in small- or micro-ORC systems. In general, the selection of expansion machines should consider many factors, such as the power capacity, isentropic efficiency, cost, complexity, etc., and different expansion machines have their own applicable scope so that reasonable selection is based on system operation and working conditions.
In ORC, organic working fluid plays a decisive role. The working fluid selection can greatly affect economic feasibility of an ORC while the economic performance of ORC system is an important factor affecting its application and development. Moreover, the impact on the environment is also greatly affected by working fluid selection. From a historical perspective, chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) dominated organic working fluids from 1931 to the early 1990s. Since the ratification of the Montreal Protocol in 1987 and the Kyoto Protocol in 1997, more and more attention has been paid to the development of environmentally friendly organic working fluids. Therefore, based on environmental concerns, CFC working fluids have been phased out and HCFC working fluids will be phased out by 2040 for developing countries. Hydrofluoroolefins (HFO) working fluids are drawing more and more attention. During the transition period, R123 (HCFC working fluid) [
23,
24,
25,
26,
27,
28,
29,
30] and R245fa (HFC working fluid) [
24,
25,
26,
27,
31,
32,
33,
34] are two frequently-used working fluids in ORC. Therefore, the economic analysis of ORC utilizing R123 and R245fa is of great significance. Especially for developing countries, many ORC systems using R123 or R245fa as working fluids are in use or in development.
One of the first articles focusing on exergoeconomic analyses was carried out by Tsatsaronis in the 1980s [
35]. Afterwards, much research on economic analysis of thermodynamic cycle system has been conducted from different aspects. Different methods and equations have been developed and proposed accordingly. Kim et al. [
36] developed an exergy-costing method by assigning a single unit cost to a specific exergy, regardless of the type of exergy stream and state of the stream. Applying the cost-balance equation to each component of a 1000 kW gas turbine cogeneration system, they obtained exergy costs, production cost of electricity, and the lost costs of each component of the system. Based on the Specific Exergy Costing (SPECO) approach, Lazzaretto and Tsatsaronis [
37] proposed a systematic and general methodology for defining and calculating exergetic efficiencies and exergy related costs in thermal systems. They introduced some guidelines that can generalize and simplify the definitions of exergetic efficiencies and the costing procedures. Those guidelines significantly reduce the arbitrariness in applications of exergy costing. Using levelized energy cost (LEC) as an economic indictor, Zhang et al. [
38] conducted a performance comparison and parametric optimization of subcritical ORC and transcritical power cycle system for low-temperature geothermal power generation. They found that, although the thermal efficiency and exergy efficiency of R125 in transcritical cycle is 46.4% and 20% lower than that of R123 in subcritical ORC, it provides 20.7% larger recovery efficiency. The LEC value is relatively low. Moreover, 22032L petroleum is saved and 74,019 kg CO
2 is reduced per year when the LEC value is used as the objective function. Abusoglu and Kanoglu [
39] discussed the concepts of exergetic cost and cost accounting methods, and conducted a brief historical overview on the exergoeconomic analysis and optimization of combined heat and power production (CHPP). Compared with conventional energy analysis, these methods can solve problems related to complex energy systems. Vélez et al. [
40] presented an overview of the technical and economic aspects, as well as the market evolution of the Organic Rankine Cycle (ORC). In their research, because of the lack of any real installations to show the cost, a simple economic analysis has been carried out to find the maximum investment that a project can assume when the return on investment is required in a year. Fiaschi et al. [
41] used investment and operation and maintenance (O&M) costs as the indicators to analyze and compare exergoeconomic performance of ORC and Kalina cycles, which are used to exploit low and medium-high temperature heat from two different geothermal sites. Yari et al. [
42] used capital recovery factor (CRF) as the indicator to conduct an exergoeconomic comparison of TLC (trilateral Rankine cycle), ORC and Kalina cycle using a low-grade heat source. They found that, although the TLC can achieve a higher net output power compared with ORC and Kalina (KCS11 (Kalina cycle system 11)) systems, its product cost is greatly affected by the expander isentropic efficiency. They also observed that, for both ORC and Kalina systems, the optimum operating condition for maximum net output power differs from that for minimum product cost. Meinel et al. [
43] compared economic performance of ORC processes at different scales using purchased equipment costs (PEC), maintenance and operating costs (MO), and capital investment cost (CIC) as the indicators. Esen et al. [
44] used the annual cost method to make a technoeconomic comparison of ground-coupled and air-coupled heat pump system for space cooling. Purchase cost and payback period [
45] were used by Varga and Csaba as the indicators to conduct a techno-economic evaluation of waste heat recovery by organic Rankine cycle using pure light hydrocarbons and their mixtures as working fluid in a crude oil refinery. Luo et al. [
46] used total capital investment as the indicator to make a thermo-economic analysis and optimization of a zoetropic fluid organic Rankine cycle with liquid–vapor separation during condensation.
Based on the reviewed papers, it can be seen that different indicators are used to evaluate the economic performance of different thermodynamic systems. However, many indicators are proposed for a particular process or system or, in most work, only one or two indicators are used. Therefore, in this work, five traditional and classical indicators, namely total cost, net earnings, payback period, return on investment, and levelized energy cost, were selected for thermo-economic analysis of ORC using R123 and R245fa as working fluid. Considering that the above five indicators mainly focus on the present economic performance evaluation, a new indicator, which is called present value of total profit in system service life, is proposed. This new indicator can be used to evaluate the economic performance of engineering technology solution throughout its service life. Using these six indicators, the thermo-economic evaluation model of ORC with R123 and R245fa was established and the variation effect of influencing factor on system economic performance was calculated and analyzed. Herein, the economic performance of an ORC demonstration project is reported.
3. Results and Discussion
3.1. Variation Effects of Evaporation Temperature on Economic Performance of ORC System
In this study, the ORC system operated under subcritical condition. Both R123 and R245fa are dry working fluids with positive slopes of the saturation vapor curves. Therefore, after the isentropic expansion process to produce work, these two working fluids are at a superheated state. The upper limit of the evaporation temperature (inlet temperature of expander) was set to the temperature corresponding to the maximum entropy value on the saturated vapor curve near critical region of working fluid in T-s diagram. The condensation temperature was set at 27 °C and the heat source temperature was set at 197 °C.
Figure 2 depicts the total cost of ORC system at different evaporation temperatures. In the figure, it can be seen that the total cost of ORC system with R123 as working fluid decreases with the increase of evaporation temperature, while, for the ORC system with R245fa as working fluid, its total cost increases. With the increase of evaporation temperature, as for the R123 system, its heat transfer area in evaporator decreases. The output power of expander increases first and then decreases. The heat transfer area in condenser decreases. The work consumed by pump increases. The investment reduction rate of the evaporator is greater than the increase rate of the expander investment, so the total investment of system decreases as a whole. As for R245fa system, the heat transfer areas in both evaporator and condenser decreases. Both the output power of expander and the work consumed by pump increases. The investment reduction rate of the evaporator is less than the increase rate of the expander investment, so the total investment increases as a whole.
Figure 3 depicts the net earnings (NE) of ORC system at different evaporation temperatures. In the figure, it can be seen that, with the increase of evaporation temperature, the net earnings (NE) of the R123 system increase first and then decreases, while, for the R245fa system, its net earnings (NE) increase. Multiplying the output power by the working fluid flow, the product obtained is sold in units of on-grid electricity price within one year. This income is the net earnings (NE) of ORC system. With the increase of evaporation temperature, the flow rate of R123 decreases while the output work increases. When the two items are multiplied, the net earnings (NE) of ORC system show a maximum at the evaporation temperature of 120 °C. As for the R245fa system, the reduction rate of mass flow rate of working fluid is less than the increase rate of output work of system, thus the net earnings (NE) of system increases.
Figure 4,
Figure 5 and
Figure 6 depict the payback period (PP), return on investment (ROI), and levelized energy cost (LEC) of ORC system at different evaporation temperatures, respectively. In the figures, it can be seen that there is an optimal value for each of the above three indicators. For R123 system, the optimum evaporation temperature is 125 °C and it is 122 °C for R245fa system. All three indicators are based on the ratio of net earnings to total cost of system. Therefore, an optimal value appears when the above two indicators have different variation rates.
Present value of total profit in system service life of ORC system at different evaporation temperatures is depicted by
Figure 7. In the figure, it can be seen that, for R123 system, there is an optimal value at the evaporation temperature of 120 °C, while, for R245fa system, the value increases with the increase of evaporation temperature. The present value of total profit in system service life of ORC system is related to two factors, total cost and net earnings of the system. The latter affects the value greatly. For the R123 system, the net earnings reach maximum at the evaporation temperature of 120 °C and the total cost of the system is small. Therefore, the present value of total profit in system service life has a maximum value at 120 °C. For R245fa system, its increase rate of net earnings is greater than that of total cost of the system. Therefore, its present value of total profit in system service life increases with the increase of evaporation temperature.
From the above discussion, it can be seen that, for R123 system, its payback period (PP), return on investment (ROI), and levelized energy cost (LEC) reach optimal at the evaporation temperature of 125 °C and its net earnings (NE) and present value of total profit in system service life have the optimal value at the evaporation temperature of 120 °C. Considering that the total cost of the system is relatively low when the evaporation temperature is 125 °C, this is the optimal evaporation temperature for R123 system.
As for R245fa system, its payback period (PP), return on investment (ROI), and levelized energy cost (LEC) reach optimal at the evaporation temperature of 122 °C. When above 122 °C, its growth rate of total cost of the system accelerates, while its growth rates of net earnings and present value of total profit in system service life slow down. Therefore, 122 °C is the optimal evaporation temperature for R245fa system.
3.2. Variation Effects of Condensation Temperature on Economic Performance of ORC System
In this study, the evaporation temperature of R123 was set at 150 °C and 127 °C for R245fa. The condensation temperature was in the range of 23–43 °C. The heat source temperature was set at 197 °C Total cost, net earnings, payback period, return on investment, levelized energy cost, and present value of total profit in system service life of ORC system at different condensation temperatures are depicted in
Figure 8,
Figure 9,
Figure 10,
Figure 11,
Figure 12 and
Figure 13.
In these figures, it can be seen that, with the condensation temperature increase, there are three decreasing indicators: total cost, net earnings, and present value of total profit in system service life. With the increase of condensation temperature, the heat exchange in the condenser, the required heat transfer area, and the cost of condenser decrease, accordingly. Moreover, the output work of the system decreases and the cost of expander decreases. Therefore, both the total cost and net earnings of the system decrease. The net earnings of the system can greatly affect the present value of total profit in system service life, which also decreases accordingly. Three indicators, payback period (PP), return on investment (ROI), and levelized energy cost (LEC) of ORC system, which are based on the ratio of net earnings to total cost of system, have an optimal value of condensation temperature. R123 and R245fa systems have optimal condensation temperatures of 33 °C and 27 °C, respectively. In summary, when the above six indicators are considered, the optimal condensation temperature of R123 system is determined to be 33 °C and that of R245fa system is 27 °C.
3.3. Variation Effects of Heat Source Temperature on Economic Performance of ORC System
The flue gas is used as heat source. For R123 system, the heat source temperature was set in the range of 127–227 °C and that for R245fa system was 107–197 °C. The condensation temperature was set at 27 °C. Considering that the outlet temperature of heat source should not be lower than the inlet temperature of evaporator when pinch point temperature difference method is used, the above heat source temperatures were set. Total cost, net earnings, payback period, return on investment, levelized energy cost, and present value of total profit in system service life of ORC system at different heat source temperatures are depicted in
Figure 14,
Figure 15,
Figure 16,
Figure 17,
Figure 18 and
Figure 19.
In the above figures, it can be seen that, with the increase of heat source temperature, there are three increasing indicators: total cost, net earnings, and present value of total profit in system service life. With the increase of heat source temperature, the mass flow rate of working fluid increases. The required heat transfer areas in evaporator and condenser increase and their costs increase, accordingly. Both the output work of expander and the work consumed by pump increase and their costs increase, accordingly. Therefore, the total cost of system increases and its growth rate accelerates when the heat source temperature is above 217 °C (for R123 system) and 177 °C (for R245fa system). The net earnings of the system increases because of the increase of both the output work of the system and the mass flow rate of working fluid. The net earnings of the system can greatly affect the present value of total profit in system service life, which also increases, accordingly. Three indicators, payback period (PP), return on investment (ROI), and levelized energy cost (LEC) of ORC system, have an optimal value of heat source temperature. R123 and R245fa systems have optimal heat source temperatures of 217 °C and 177 °C, respectively. In summary, when the above six indicators are considered, the optimal heat source temperature of R123 system is determined to be 217 °C and that of R245fa system is 177 °C.
3.4. Variation Effects of Mass Flow Rate of Heat Source on Economic Performance of ORC System
To study the effect of mass flow rate of heat source on the economic performance of ORC system, for R123 system, the evaporation temperature was set at 150 °C, condensation temperature was set at 27 °C, and heat source temperature was set at 197 °C. For R245fa system, the evaporation temperature was set at 127 °C, condensation temperature was set at 27 °C, and heat source temperature was set at 197 °C. Total cost, net earnings, payback period, return on investment, levelized energy cost, and present value of total profit in system service life of ORC system with different mass flow rates of heat source are depicted in
Figure 20,
Figure 21,
Figure 22,
Figure 23,
Figure 24 and
Figure 25.
From the above figures, it can be seen that, with the increase of mass flow rate of heat source, although the total cost of the system increases, the net earnings, return on investment, and present value of total profit in system service life increase. Meanwhile, the payback period and levelized energy cost decrease. Therefore, the economic performance of system becomes better and better with the increase of mass flow rate of heat source.
4. A Demonstration Project Report
A demonstration project of ORC system with R123 as working fluid was established in Liulin, Shanxi province, P. R. China. This project is used for the waste heat recover of flue gas from a gas-fired internal combustion engine generator unit.
Figure 26 presents a photograph of the ORC system demonstration project. Its scheme is depicted in
Figure 27. The working condition parameters of the demonstration ORC system are listed in
Table 5. Its output power is 11 kW.
The investment cost of the equipment used in the demonstration ORC system is listed in
Table 6.
Table 7 gives the value of economic indicators used to analyze the economic performance of demonstration ORC system.
In the previous section, the calculation results show that the optimal evaporation temperature of R123 is 125 °C, optimal condensation temperature is 33 °C, and optimal heat source temperature is 217 °C. For R245fa, the optimal evaporation temperature is 122 °C, optimal condensation temperature is 27 °C, and optimal heat source temperature is 177 °C.
Figure 28 depicts the proportion of equipment investment in the ORC system with R123 as working fluid at the optimal evaporation temperature, optimal condensation temperature, and optimal heat source temperature. The proportion of equipment investment in demonstration project is also depicted in
Figure 28. The proportion of equipment investment in the ORC system with R245fa as working fluid at the optimal evaporation temperature, optimal condensation temperature, and optimal heat source temperature is depicted in
Figure 29.
For R123 and R245fa systems, it was found that the investment in heat exchanger accounted for the largest proportion, followed by expander, then pump, and the least was the investment in working fluid. For the demonstration project, the investment in heat exchanger accounted for the largest proportion, followed by expander, working fluid accounts for the third, and the least was the investment in pump. This is because, as the key equipment in ORC system, the expander used in the demonstration project is a single screw expander, which was independently researched, developed and produced by our research group. Therefore, its cost was greatly reduced. Moreover, the previous calculation of the investment in working fluid was based on the total quantity that fills heat exchanger chamber and the system piping. In the demonstration project, the additional quantity of working fluid caused by leakage and loss should be considered. Therefore, in the demonstration project, the investment proportion of working fluid was higher than that of pump.
5. Conclusions
Considering traditional and classical indicators mainly focus on the present economic performance evaluation, a relatively new indicator, which is called present value of total profit in system service life, is proposed in this paper. Economic performance of ORC systems with R123 and R245fa as working fluid was analyzed using five traditional economic indicators (total cost, net earnings, payback period, return on investment, and levelized energy cost) and the relatively new indicator.
From the calculation results, the following conclusion can be drawn.
(1) Considering the variation effects of evaporation temperature on economic performance of ORC system, for R123 system, its payback period (PP), return on investment (ROI), and levelized energy cost (LEC) reach optimal at the evaporation temperature of 125 °C and its net earnings (NE) and present value of total profit in system service life have the optimal value at the evaporation temperature of 120 °C. Considering that the total cost of the system is relatively low when the evaporation temperature is 125 °C, this is the optimal evaporation temperature for R123 system. As for R245fa system, its payback period (PP), return on investment (ROI), and levelized energy cost (LEC) reach optimal at the evaporation temperature of 122 °C. When above 122 °C, its growth rate of total cost of the system accelerates, while its growth rates of net earnings and present value of total profit in system service life slow down. Therefore, 122 °C is the optimal evaporation temperature for R245fa system.
(2) Considering the variation effects of condensation temperature, three indicators, payback period (PP), return on investment (ROI), and levelized energy cost (LEC) of ORC system, which are based on the ratio of net earnings to total cost of system, have an optimal value of condensation temperature. R123 and R245fa systems have optimal condensation temperatures of 33 °C and 27 °C, respectively.
(3) Considering the variation effects of heat source temperature, with the increase of heat source temperature, there are three increasing indicators: total cost, net earnings, and present value of total profit in system service life. R123 and R245fa systems have optimal heat source temperatures of 217 °C and 177 °C, respectively.
(4) Considering the variation effects of mass flow rate of heat source, with the increase of mass flow rate of heat source, although the total cost of system increases, the net earnings, return on investment, and present value of total profit in system service life increase. Meanwhile, the payback period and levelized energy cost decrease. Therefore, the economic performance of system becomes better and better with the increase of mass flow rate of heat source.
(5) If the above four variation effects are considered comprehensively, the results show that the optimal evaporation temperature of R123 is 125 °C, optimal condensation temperature is 33 °C, and optimal heat source temperature is 217 °C. For R245fa, the optimal evaporation temperature is 122 °C, optimal condensation temperature is 27 °C, and optimal heat source temperature is 177 °C. The investment in heat exchanger accounted for the largest proportion, followed by expander, then pump, and the least was the investment in working fluid.
(6) The economic performance of an ORC demonstration project was reported. The investment in heat exchanger accounted for the largest proportion, followed by expander, working fluid accounts for the third, and the least was the investment in pump.