1. Introduction
Salicylic acid or 2-hydroxybenzoic acid is widely distributed in the plant kingdom [
1], and is most used for its analgesic, antipyretic and anti-inflammatory properties [
2]. Salicylic acid (SAH) is an important raw material that has been used as an intermediate to synthesize drugs (such as aspirin) and cosmetics (used for the treatment of seborrheic dermatitis) [
3].
Currently, the production of salicylic acid is based on Kolbe-Schmitt [
4]. First, sodium phenolate is synthesized by the reaction between phenol and NaOH. Second, the intermediate is transformed into sodium salicylate (SANa) by a carboxylation reaction under conditions of high pressure, high temperature and CO
atmosphere. Third, salicylic acid is obtained by acidification using a huge amount of H
SO
. However, this process will not only consume a considerable amount of H
SO
, but will generate numerous Na
SO
waste solutions with a concentration greater than 0.1%
w/
w [
5].
Figure 1 shows the block diagram of the process for obtaining salicylic acid.
The production of salicylic acid is based on the Kolbe-Schmitt reaction by the following reaction, shown in
Figure 2.
As an advanced technical and environmentally friendly process, bipolar membrane electrodialysis (BMED) has been used as an alternative for the production of salicylic acid [
5]. Electrodialysis technology has been applied to the treatment of high salt wastewater on an industrial scale since the 1950s [
6]. Furthermore, the use of a bipolar membrane was introduced into the process in the 1970s, forming a new technology, electrodialysis with bipolar membranes (BMED), and expanding the application of this approach [
7]. Among membrane technologies, electromembrane processes are promising technologies for the recovery of organic acids [
8]. Electrodialysis (ED) is a separation process based on ion exchange membranes where positive ions are transported through a cation exchange membrane (CEM), and negative ions are transported through an anion exchange membrane (AEM) due to an applied electric field [
9]. Electrodialysis (ED) allows the concentration and separation of cations/anions using cation exchange membranes (CEM) and anion exchange membranes (AEM). Furthermore, electrodialysis with bipolar membranes (BMED) is used to produce acids and bases from the corresponding salts [
10,
11].
Bipolar membrane electrodialysis technology (BMED) can be considered as a combination of a cation exchange membrane (CEM) and an anion exchange membrane (AEM); however, it has a different function than unipolar membranes [
12]. BMED technology has been applied to the production of propionic acid [
13], salicylic acid [
14], gluconic acid [
15] and other organic acids. The BMED dissociates water into protons and hydroxide, which move through the cation and anion layers of the bipolar membrane (FBM), respectively, and thus produce acidic and alkaline currents [
16,
17].
Independently, BMED has also been used effectively to produce or purify acids, as well as to adjust pH during fermentation or chemical synthesis in food and biochemical processing [
18,
19]. The BMED process has also been widely used for many years in the recovery of process water [
20]. In [
21], they used bipolar membranes for internal pH control in the electrodialysis of amino acids. Furthermore, [
22] mentioned that the BMED process is a promising technology for the treatment of textile wastewater, as it produces acid and base from the salt content of the wastewater. In addition, it does not produce any waste stream that needs further treatment. Then, [
23] observed that the maximum acid-base conductivity (90,000 µS/cm in acid, 60,000 µS/cm in base) was reached with the BMED system using only the salt in the concentrate. Relating concentrations correspond to approximately 1.44% acids(HCl) and 2% bases(NaOH). Independently, [
24] suggested an economic value of BMED for desalination of high salinity textile wastewater.
When an electric field is applied to the BMED cell, the following cathodic and anodic reactions take place at the related electrodes, [
25] as shown in Equations (1) and (2).
The water molecules that diffuse in the bipolar membrane are divided into ions H
and OH
at the bipolar membrane interface both by the applied electric field and by the catalytic effect of the bipolar junction [
26] as shown in Equation (
3).
The H ions pass through the cation exchange layer of the BPM towards the cathode side, while the OH ions pass through the anion exchange layer towards the anode side.
The salts in the feed stream ionize in aqueous medium as shown in Equation (
4). The cation and anion exchange membranes change the direction of the ions to the appropriate compartments under the effect of the electric field.
The C
H
O
(SA
) ions released migrate through the AEM and combine with the H
ions produced by the dissociation of water from the bipolar membrane to form pure salicylic acid (acid compartment), as shown in Equation (
5).
Meanwhile, the released Na
ions migrate through the CEM and combine with the OH
ions produced by the dissociation of water to form pure sodium hydroxide (base compartment) [
8], as shown in Equation (
6).
As an environmentally friendly and technical advanced process, bipolar membrane electrodialysis (BMED) has been used as an alternative for the production of salicylic acid [
5].
The contribution of the work is the implementation, construction and evaluation of its own bipolar electrodialysis module. From there, the present study aimed to study the feasibility of the bipolar membrane electrodialysis process, and to evaluate the influence of operating factors during the bipolar electrodialysis process of the sodium salicylate salt in the formation of salicylic acid. Process parameters such as applied voltage, salt concentration, initial acid concentration, and flow affecting BMED have been evaluated. The result of this research shows the performance of the BMED process in the synthesis of salicylic acid and its influence on the operating variables of the equipment with respect to the acid concentration.
The present work is divided as follows: in
Section 2 we mention the materials and methods to be used, in
Section 3 we present the results and discussions carried out, and finally in
Section 4 we discuss the conclusions obtained from this study.
2. Materials and Methods
2.1. Materials
The chemicals used in our research were analytically pure sodium salicylate salt, sodium hydroxide (NaOH), sodium sulfate, and phenolphthalein. Deionized water with a concentration of 1 ppm was used for the analysis. The glass materials used were burettes to carry out the titration operation.
2.2. Membranes
The experiment involved the use of three types of membranes, cation exchange (CEM), anion exchange (AEM), and bipolar membrane (FBM) were supplied by the company (Fumatech Bwt GmbH, Bietigheim Bissingen, Germany) for the study. For a good functioning of the membrane, it is first immersed in distilled water for a period of 24 h and then in an aqueous solution of NaCl 0.25 N for the other 24 h; the characteristics are shown in
Table 1.
For FBM, the membrane area resistance was measured as Cl
and Na
in 0.5 M NaCl solution and 0.25 M Na
SO
electrode rinse solution at 25
C, respectively [
28].
2.3. Chemical Analysis
The changes in the concentration of salicylic acid and sodium hydroxide were determined by acid-base titration with a calibrated solution of 0.01 N NaOH and 0.01 N HCl using phenolphthalein as an indicator. The salicylic acid concentration was calculated by Equation (
7) [
14].
C (mol/L): concentration of the calibrated NaOH solution.
V (L): volume of the NaOH.
V (L): volume of acid used for titration.
C: obtained concentration of salicylic acid.
2.4. Membrane Configuration
The BMED technology has been developed as a sustainable approach to split an aqueous saline stream into its corresponding acid and base without any use of chemicals [
7]. BMED is configured with a series of ion exchange membranes, including anion exchange membranes (AEM), cation exchange membranes (CEM), and bipolar membranes (FBM) between a pair of electrodes [
29]. This is shown in
Figure 3.
The transport of water by osmosis in the BMED compartments is not within the scope of this work. However, ion exchange membranes in electrodialysis should possess high perm selectivity and conductivity, low resistance, and high mechanical, dimensional, and chemical stability [
9,
30,
31].
2.5. Electrodialysis Cell with Bipolar Membrane
The bipolar membrane electrodialysis cell is a filter press type as shown in
Figure 4, with five compartments (acid, salt, base and washing of cathode electrodes and washing of anode electrodes). It was built with acrylic material on which four membranes are assembled with their respective mesh-shaped turbulence promoters, alternately fixed and secured with eight cross bars with nuts to prevent leakage, mixing or spilling of the liquid as shown in
Figure 5.
Rubber gaskets were placed between each frame and membrane that allows a seal in order to maintain uniform flow distribution within the cells, with two acrylic plates at the ends of each, with three inlets and three outlets for the flow of solutions.
The external acrylic plates allow the system to be kept under pressure, providing stability and resistance to the set of cells. The the electrodes are inserted into two 1.5 cm thich acrylic frames, each with an inlet and an outlet through which the electrode wash solution enters.
In all compartments, solutions were circulated in a batch mode using pumps; changes in concentration were measured by sampling at time intervals.
A direct current generator supplied a constant current. The titanium electrode, both anode and cathode, has a working area of 100 cm, and each membrane has an effective area of 90 cm (total effective membrane area of 360 cm). The experiments were carried out at a room temperature of 28 C. As electrode washing solution, 2 L of 0.25 M sodium sulfate was used, the initial concentration of sodium hydroxide in each experiment being 0.01 N.
2.6. Calculation of Current Efficiency and Energy Consumption
The performance of BMED for salicylic acid synthesis was evaluated in terms of energy consumption (E), and current efficiency ().
The current efficiency (
) is important for the characterization of the bipolar electrodialysis process. It was calculated by Equation (
8) [
32].
and (mol/L): are the concentrations of salicylic acid at t and zero time respectively.
: is the initial volume of the acid cycle.
F: is the Faraday constant (96,485 Cmol).
t: (min) is the test time.
: is the current applied; where z is the ion’s absolute valence (z = 1).
N: is the number of repeating units (N = 1).
The energy consumption E(kWh/kg) was calculated by Equation (
9) [
33].
U: is the voltage drop across the BMED stack (V).
I: is the current (A).
t: (min) is the test time.
M: is the molecular weight of salicylic acid 138,122 (g/mol).
It is important to note that organic solutions are poor electrical conductors and can cause significant drops in electrical potential in BMED cells, causing higher energy consumption in said cell.
However, a limitation is that the products to be treated by BMED must have a high mineral content to allow good electrical conductivity. This is in order to decrease the overall resistance of the electrodialysis cell [
34].
2.7. Experimental Design Based on Taguchi Method
The Taguchi method was used to design the experiments. The Taguchi method applies fractional factorial experimental designs, called orthogonal arrays, to reduce the number of experiments. The selection of a suitable orthogonal array depends on the number of control factors and their levels. The factors and their levels are presented in
Table 2.
In this work, the effect of four important factors, including electric potential, initial concentration of the salicylic acid, the concentration of the salt, and the volumetric flow of recirculation of the solutions and each factor was studied at three levels on the concentration of salicylic acid. The design of the experiment using the Taguchi method provides a simple, efficient, and systematic approach to determine the optimum conditions [
35]. With the selection of the
(
) orthogonal array, the number of experiments required can be reduced to nine, which should be conducted in order to study the main effects and interactions, whereas full factorial experimentation would require
experiments.
For the membrane division voltage at 100 mA/cm
is less than 1.2 V, in 0.5 M NaCl solution and 0.25 M Na
SO
electrode rinse solution at 25
C [
28]. In [
7] mentioned that the maximum estimated voltage is 16 V, taking into account the possible losses. Then we chose an interval of 5 to 15 V to carry out our experiments.
The other parameters have been chosen by conditions of the experiment, the electric potential being the most influential factor in the process to be carried out.
BMED experiments were performed using aqueous sodium salicylate solutions. The set of factor levels to be tested, the experimental parameters and their levels are given in
Table 3.
4. Conclusions
A laboratory scale experimental setup was used to verify the viability of BMED to produce salicylic acid from sodium salicylate. An electrodialysis module has been constructed with commercial cationic, anionic and bipolar exchange membranes for the conversion of sodium salicylate to salicylic acid.
The effect of operating conditions, such as applied electrical potential, salt concentration, initial acid concentration, and volumetric flow on BMED yields was investigated. The performance of the module was quantified in terms of salicylic acid concentration, electric current efficiency and specific energy consumption (kWh/kg of salicylic acid), as shown in the figures in
Section 3.1.
Taguchi’s methodology shows us that in
Figure 6, the electric potential of the cell and the initial acid concentration are the most representative parameters of the salicylic acid production process. The results observed in
Figure 7 and
Figure 8 indicate average electric current efficiencies of 85.3%, and the specific energy consumption is 2.24 kWh/kg of salicylic acid, respectively.
The experimental results indicate that the four-compartment BMED process can be applied to prepare salicylic acid and sodium hydroxide, and will also achieve environmental benefits.