Age-Independent Clinical Outcome in Proximal Humeral Fractures: 2-Year Results Using the Example of a Precontoured Locking Plate
Abstract
:1. Introduction
2. Materials and Methods
2.1. Case Selection
2.2. Surgical Approach and Postoperative Management
2.3. Functional and Radiologic Follow-Ups
2.4. Statistical Analysis
3. Results
3.1. Demographic and Clinical Characteristics of the Study Population
3.2. Functional Outcomes
3.3. Radiological Findings
3.4. Clinical Complications
4. Discussion
Limitations
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Conflicts of Interest
References
- Passaretti, D.; Candela, V.; Sessa, P.; Gumina, S. Epidemiology of proximal humeral fractures: A detailed survey of 711 patients in a metropolitan area. J. Shoulder Elb. Surg. 2017, 26, 2117–2124. [Google Scholar] [CrossRef] [PubMed]
- Court-Brown, C.; Clement, N.; Duckworth, A.; Biant, L.; McQueen, M. The changing epidemiology of fall-related fractures in adults. Injury 2017, 48, 819–824. [Google Scholar] [CrossRef] [PubMed]
- Palvanen, M.; Kannus, P.; Niemi, S.; Parkkari, J. Update in the Epidemiology of Proximal Humeral Fractures. Clin. Orthop. Relat. Res. 2006, 442, 87–92. [Google Scholar] [CrossRef] [PubMed]
- Handoll, H.; Brealey, S.; Rangan, A.; Keding, A.; Corbacho, B.; Jefferson, L.; Chuang, L.-H.; Goodchild, L.; Hewitt, C.; Torgerson, D. The ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation) trial—A pragmatic multicentre randomised controlled trial evaluating the clinical effectiveness and cost-effectiveness of surgical compared with non-surgical treatment for proximal fracture of the humerus in adults. Heal. Technol. Assess. 2015, 19, 1–280. [Google Scholar] [CrossRef] [Green Version]
- Launonen, A.P.; Sumrein, B.O.; Reito, A.; Lepola, V.; Paloneva, J.; Jonsson, K.B.; Wolf, O.; Ström, P.; Berg, H.E.; Felländer-Tsai, L.; et al. Operative versus non-operative treatment for 2-part proximal humerus fracture: A multicenter randomized controlled trial. PLoS Med. 2019, 16, e1002855. [Google Scholar] [CrossRef] [Green Version]
- Sabesan, V.J.; Lombardo, D.; Petersen-Fitts, G.; Weisman, M.; Ramthun, K.; Whaley, J. National trends in proximal humerus fracture treatment patterns. Aging Clin. Exp. Res. 2017, 29, 1277–1283. [Google Scholar] [CrossRef]
- Sumrein, B.O.; Huttunen, T.; Launonen, A.P.; Berg, H.E.; Felländer-Tsai, L.; Mattila, V.M. Proximal humeral fractures in Sweden—A registry-based study. Osteoporos. Int. 2017, 28, 901–907. [Google Scholar] [CrossRef]
- Südkamp, N.; Bayer, J.; Hepp, P.; Voigt, C.; Oestern, H.; Kääb, M.; Luo, C.; Plecko, M.; Wendt, K.; Köstler, W.; et al. Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate. Results of a prospective, multicenter, observational study. J. Bone Jt. Surg. 2009, 91, 1320–1328. [Google Scholar] [CrossRef]
- Brorson, S.; Rasmussen, J.V.; Frich, L.H.; Olsen, B.S.; Hróbjartsson, A. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review. Injury 2012, 43, 999–1005. [Google Scholar] [CrossRef]
- Tepass, A.; Rolauffs, B.; Weise, K.; Bahrs, S.D.; Dietz, K.; Bahrs, C. Complication rates and outcomes stratified by treatment modalities in proximal humeral fractures: A systematic literature review from 1970–2009. Patient Saf. Surg. 2013, 7, 34. [Google Scholar] [CrossRef] [Green Version]
- Helwig, P.; Bahrs, C.; Epple, B.; Oehm, J.; Eingartner, C.; Weise, K. Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? Acta Orthop. 2009, 80, 92–96. [Google Scholar] [CrossRef]
- Lorenz, G.; Schönthaler, W.; Huf, W.; Komjati, M.; Fialka, C.; Boesmueller, S. Complication rate after operative treatment of three- and four-part fractures of the proximal humerus: Locking plate osteosynthesis versus proximal humeral nail. Eur. J. Trauma Emerg. Surg. 2020, 47, 2055–2064. [Google Scholar] [CrossRef]
- Dey Hazra, R.O.; Blach, R.M.; Ellwein, A.; Katthagen, J.C.; Lill, H.; Jensen, G. Latest Trends in the Current Treatment of Proximal Humeral Fractures—An Analysis of 1162 Cases at a Level-1 Trauma Centre with a Special Focus on Shoulder Surgery. Zeitschrift Orthopädie Unfallchirurgie 2021. [Google Scholar] [CrossRef]
- Warnhoff, M.; Lill, H.; Jensen, G.; Ellwein, A.; Dey Hazra, R.O. Proximale Humerusfraktur—Was sagt die aktuelle Literatur? Obere Extrem. 2019, 14, 9–17. [Google Scholar] [CrossRef]
- Katthagen, J.C.; Dey Hazra, R.O.; Raschke, M.J.; Heilmann, L.; Michel, P.; Lill, H.; Schliemann, B. Innovationen bei der Behandlung der proximalen Humerusfraktur. Arthroskopie 2018, 32, 28–39. [Google Scholar] [CrossRef]
- Helfen, T.; Siebenbürger, G.; Fleischhacker, E.; Gleich, J.; Böcker, W.; Ockert, B. Operative treatment of 2-part surgical neck type fractures of the proximal humerus in the elderly: Cement augmented locking plate PHILOS™ vs. proximal humerus nail multiloc®. Injury 2020, 51, 2245–2252. [Google Scholar] [CrossRef] [PubMed]
- Hengg, C.; Nijs, S.; Klopfer, T.; Jaeger, M.; Platz, A.; Pohlemann, T.; Babst, R.; Franke, J.; Kralinger, F. Cement augmentation of the proximal humerus internal locking system in elderly patients: A multicenter randomized controlled trial. Arch. Orthop. Trauma Surg. 2019, 139, 927–942. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Röderer, G.; Scola, A.; Schmoelz, W.; Gebhard, F.; Windolf, M.; Hofmann-Fliri, L. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures. Injury 2013, 44, 1327–1332. [Google Scholar] [CrossRef]
- Laux, C.J.; Grubhofer, F.; Werner, C.M.L.; Simmen, H.-P.; Osterhoff, G. Current concepts in locking plate fixation of proximal humerus fractures. J. Orthop. Surg. Res. 2017, 12, 1–9. [Google Scholar] [CrossRef] [Green Version]
- Ziegler, P.; Maier, S.; Stöckle, U.; Gühring, M.; Stuby, F.M. The Treatment of Proximal Humerus Fracture Using Internal Fixation with Fixed-angle Plates. Dtsch. Aerzteblatt Online 2019, 116, 757–763. [Google Scholar] [CrossRef]
- Katthagen, J.C.; Schwarze, M.; Warnhoff, M.; Voigt, C.; Hurschler, C.; Lill, H. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury 2016, 47, 617–624. [Google Scholar] [CrossRef] [PubMed]
- Hepp, P.; Theopold, J.; Voigt, C.; Engel, T.; Josten, C.; Lill, H. The surgical approach for locking plate osteosynthesis of displaced proximal humeral fractures influences the functional outcome. J. Shoulder Elb. Surg. 2008, 17, 21–28. [Google Scholar] [CrossRef]
- Katthagen, J.C.; Huber, M.; Grabowski, S.; Ellwein, A.; Jensen, G.; Lill, H. Failure and revision rates of proximal humeral fracture treatment with the use of a standardized treatment algorithm at a level-1 trauma center. J. Orthop. Traumatol. 2017, 18, 265–274. [Google Scholar] [CrossRef] [PubMed]
- Court-Brown, C.M.; Duckworth, A.D.; Clement, N.D.; McQueen, M.M. Fractures in older adults. A view of the future? Injury 2018, 49, 2161–2166. [Google Scholar] [CrossRef] [PubMed]
- Giardella, A.; Ascione, F.; Mocchi, M.; Berlusconi, M.; Romano, A.M.; Oliva, F.; Maradei, L. Reverse total shoulder versus angular stable plate treatment for proximal humeral fractures in over 65 years old patients. Muscle Ligaments Tendons J. 2017, 7, 271–278. [Google Scholar] [CrossRef]
- Katthagen, J.C.; Lutz, O.; Voigt, C.; Lill, H.; Ellwein, A. Cement augmentation of humeral head screws reduces early implant-related complications after locked plating of proximal humeral fractures. Obere Extrem. 2018, 13, 123–129. [Google Scholar] [CrossRef] [Green Version]
- Resch, H.; Tauber, M.; Neviaser, R.J.; Neviaser, A.S.; Majed, A.; Halsey, T.; Hirzinger, C.; Al-Yassari, G.; Zyto, K.; Moroder, P. Classification of proximal humeral fractures based on a pathomorphologic analysis. J. Shoulder Elb. Surg. 2016, 25, 455–462. [Google Scholar] [CrossRef]
- Schnetzke, M.; Bockmeyer, J.; Porschke, F.; Studier-Fischer, S.; Grützner, P.-A.; Guehring, T. Quality of Reduction Influences Outcome After Locked-Plate Fixation of Proximal Humeral Type-C Fractures. J. Bone Jt. Surg. 2016, 98, 1777–1785. [Google Scholar] [CrossRef] [PubMed]
- Cohen, J. Statistical Power Analysis for the Behavioral Sciences, 2nd ed.; Laurence Erlbaum Associates: Hillsdale, NJ, USA, 1988. [Google Scholar]
- Gignac, G.; Szodorai, E.T. Effect size guidelines for individual differences researchers. Pers. Individ. Differ. 2016, 102, 74–78. [Google Scholar] [CrossRef]
- Bergdahl, C.; Ekholm, C.; Wennergren, D.; Nilsson, F.; Möller, M. Epidemiology and patho-anatomical pattern of 2011 humeral fractures: Data from the Swedish Fracture Register. BMC Musculoskelet. Disord. 2016, 17, 159. [Google Scholar] [CrossRef] [Green Version]
- Launonen, A.P.; Lepola, V.; Saranko, A.; Flinkkilä, T.; Laitinen, M.; Mattila, V.M. Epidemiology of proximal humerus fractures. Arch. Osteoporos. 2015, 10, 1–5. [Google Scholar] [CrossRef] [PubMed]
- Schliemann, B.; Siemoneit, J.; Theisen, C.; Kösters, C.; Weimann, A.; Raschke, M.J. Complex fractures of the proximal humerus in the elderly—outcome and complications after locking plate fixation. Musculoskelet. Surg. 2012, 96, 3–11. [Google Scholar] [CrossRef]
- Yang, T.-C.; Su, Y.-P.; Chang, M.-C. The elderly have similar outcomes compared to younger patients after ORIF with locking plate for comminuted proximal humerus fracture. Acta Orthop. Et Traumatol. Turc. 2018, 53, 1–5. [Google Scholar] [CrossRef] [PubMed]
- Dauwe, J.; Walters, G.; Van Eecke, E.; Vanhaecht, K.; Nijs, S. Osteosynthesis of proximal humeral fractures: A 1-year analysis of failure in a Belgian level-1 trauma centre. Eur. J. Trauma Emerg. Surg. 2020, 47, 1889–1893. [Google Scholar] [CrossRef] [PubMed]
- Barlow, J.D.; Logli, A.L.; Steinmann, S.P.; Sems, S.A.; Cross, W.; Yuan, B.J.; Torchia, M.E.; Sanchez-Sotelo, J. Locking-plate fixation of proximal humerus fractures in patients over 60 continues to be associated with a high complication rate. J. Shoulder Elb. Surg. 2019, 28, e213–e214. [Google Scholar] [CrossRef]
- Unger, S.; Erhart, S.; Kralinger, F.; Blauth, M.; Schmoelz, W. The effect of in situ augmentation on implant anchorage in proximal humeral head fractures. Injure 2012, 43, 1759–1763. [Google Scholar] [CrossRef]
- Schliemann, B.; Seifert, R.; Theisen, C.; Gehweiler, D.; Wähnert, D.; Schulze, M.; Raschke, M.J.; Weimann, A. PEEK versus titanium locking plates for proximal humerus fracture fixation: A comparative biomechanical study in two- and three-part fractures. Arch. Orthop. Trauma Surg. 2016, 137, 63–71. [Google Scholar] [CrossRef]
- Klug, A.; Gramlich, Y.; Wincheringer, D.; Schmidt-Horlohé, K.; Hoffmann, R. Trends in surgical management of proximal humeral fractures in adults: A nationwide study of records in Germany from 2007 to 2016. Arch. Orthop. Trauma Surg. 2019, 139, 1713–1721. [Google Scholar] [CrossRef]
- Jung, S.-W.; Shim, S.-B.; Kim, H.-M.; Lee, J.-H.; Lim, H.-S. Factors that Influence Reduction Loss in Proximal Humerus Fracture Surgery. J. Orthop. Trauma 2015, 29, 276–282. [Google Scholar] [CrossRef] [PubMed]
Fracture Pattern | 18–60 Years | 61–70 Years | >70 Years |
---|---|---|---|
Greater tubercle | locking plate | locking plate | locking plate |
2-part | locking plate/nail | locking plate | locking plate |
3-part | locking plate | locking plate | locking plate |
4-part | If possible locking plate/ anatomic arthroplasty | If possible locking plate/ reverse arthroplasty | If possible locking plate/ reverse arthroplasty |
Headsplit/comminuted fractures | If possible locking plate/ anatomic arthroplasty | reverse arthroplasty | reverse arthroplasty |
>65 | <65 | p-Value | |
---|---|---|---|
Age | 74.4 ± 6.6 (R: 65–89) | 52.9 ± 8.9 (R: 29–65) | p ≤ 0.001 * |
Male: Female | 10:32 | 17:20 | p = 0.007 * |
2-part fracture | 9.5% | 11% | p = 0.63 |
3-part fracture | 50% | 27% | p ≤ 0.001 * |
4-part fracture | 31% | 56.7% | p ≤ 0.001 * |
Operating time | 73 ± 31 min | 79 ± 30 min | p = 0.34 |
Quality of Fracture Reduction | >65 | <65 | |
---|---|---|---|
Head-shaft displacement | |||
Anatomical | 10 (24%) | 11 (30%) | |
Acceptable | 17 (40%) | 17 (46%) | |
Anatomical or Acceptable | 27 (64%) | 28 (76%) | |
Malreduction | 15 (36%) | 9 (24%) | |
Head-shaft alignment | |||
Normal | 35 (83%) | 29 (78%) | |
Acceptable | 7 (16%) | 4 (11%) | |
Anatomical or Acceptable | 42 (100%) | 33 (89%) | |
Malreduction | 0 | 4 (11%) | |
Tuberosity proximal migration | |||
Anatomical | 33 (79%) | 24 (65%) | |
Acceptable | 5 (12%) | 12 (32%) | |
Anatomical or Acceptable | 38 (91%) | 36 (97%) | |
Malreduction | 4 (9%) | 1 (3%) | |
Overall quality of reduction | p-value | ||
Anatomical | 7 (17%) | 6 (16%) | 0.9 (NS) |
Acceptable | 17 (40%) | 20 (54%) | 0.2 (NS) |
Anatomical or acceptable | 24 (57%) | 26 (70%) | 0.2 (NS) |
Malreduction | 18 (43%) | 11 (30%) | 0.2 (NS) |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Dey Hazra, R.-O.; Illner, J.; Szewczyk, K.; Warnhoff, M.; Ellwein, A.; Blach, R.M.; Lill, H.; Jensen, G. Age-Independent Clinical Outcome in Proximal Humeral Fractures: 2-Year Results Using the Example of a Precontoured Locking Plate. J. Clin. Med. 2022, 11, 408. https://doi.org/10.3390/jcm11020408
Dey Hazra R-O, Illner J, Szewczyk K, Warnhoff M, Ellwein A, Blach RM, Lill H, Jensen G. Age-Independent Clinical Outcome in Proximal Humeral Fractures: 2-Year Results Using the Example of a Precontoured Locking Plate. Journal of Clinical Medicine. 2022; 11(2):408. https://doi.org/10.3390/jcm11020408
Chicago/Turabian StyleDey Hazra, Rony-Orijit, Johanna Illner, Karol Szewczyk, Mara Warnhoff, Alexander Ellwein, Robert Maximillian Blach, Helmut Lill, and Gunnar Jensen. 2022. "Age-Independent Clinical Outcome in Proximal Humeral Fractures: 2-Year Results Using the Example of a Precontoured Locking Plate" Journal of Clinical Medicine 11, no. 2: 408. https://doi.org/10.3390/jcm11020408
APA StyleDey Hazra, R. -O., Illner, J., Szewczyk, K., Warnhoff, M., Ellwein, A., Blach, R. M., Lill, H., & Jensen, G. (2022). Age-Independent Clinical Outcome in Proximal Humeral Fractures: 2-Year Results Using the Example of a Precontoured Locking Plate. Journal of Clinical Medicine, 11(2), 408. https://doi.org/10.3390/jcm11020408