Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947
- (1)
- We appreciate the utilization of different Axial Length (AL) adjustments for some formulas, such as Wang–Koch (WK) AL or Cooke-modified AL (CMAL). In fact, it is well known that AL measurement can be influenced by several factors [3,4,5] and some of them can cause it to be less reliable [4]. Therefore, AL adjustments could be useful to eliminate the systematic error in IOL power calculation [5]. We have some concerns regarding the WK AL adjustment used in this paper. The authors cited only the first WK AL adjustments published in 2011 [6] and they applied them to SRKT and Holladay 1 formulas, but these AL adjustments were updated by the same authors in 2018 [7]. The updated version of the WK adjustments should be applied when AL > 26.5 mm for the Holladay 1 formula and when AL > 27.0 mm for the SRK/T formula [7]. In addition, an AL adjustment using a nonlinear equation was proposed for the Holladay 1 formula [8]. We do not understand which WK adjustments were used: the authors specified “published by Wang et al. in 2017” but they only used the 2011 citation. The authors should have only utilized the updated WK AL adjustments, as recommended by the same creators of them [7,8].
- (2)
- To evaluate the accuracy of the six formulas: Barrett Universal II, Emmetropia Verifying Optical, Hill–Radial Bias Function 3.0 Calculator, Holladay 1, Kane, and SRK/T, the authors utilized the Wilcoxon test. We wonder if they also performed a post hoc analysis, as correctly performed with Cochran’s test. Lacking a Bonferroni adjustment could lead to a type I error inflation [9].
- (3)
- We would also comment on the number of evaluated eyes. Thirty-five eyes of the 25 patients were analyzed, meaning that in some patients one eye and in others both eyes were studied. It is well known that it should be advisable to apply specific statistical methods, such as the Bootstrap or generalized estimating equations (GEE), to have valid results when evaluating bilateral eyes [10,11]. Although the authors correctly affirmed that the measurements of bilateral eyes can potentially compound data, including this point in the study’s limitations [1], they did not perform such analysis; therefore, the results could not be considered reliable. In fact, ignoring the inter-eye correlation can lead to smaller P values when both eyes are in the same group [12]. In addition, even if it is understandable that is not easy to achieve a high sample size of eyes above 28.0 mm, it is always imperative to perform a preliminary sample size calculation [9]. Unfortunately, this evaluation is missing in this paper.
- (4)
- The authors declared that they have followed the Hoffer and Savini recommendations [9] when utilizing Python Software to input IOL constants and biometrics data in online calculators of unpublished formulas. To tell the truth, Hoffer and Savini did recommend Python for a different purpose. In fact, even if Python is usually used for automated extraction from online calculators, they suggested utilizing this specific computer programming languages to optimize unpublished formulas [9], but the authors correctly did not perform a constant optimization because they analyzed a specific subgroup of long eyes. Therefore, the authors utilized Python in the right way, but for a different reason than Hoffer and Savini originally proposed.
Author Contributions
Conflicts of Interest
References
- Moshirfar, M.; Durnford, K.M.; Jensen, J.L.; Beesley, D.P.; Peterson, T.S.; Darquea, I.M.; Ronquillo, Y.C.; Hoopes, P.C. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947. [Google Scholar] [CrossRef] [PubMed]
- De Bernardo, M.; Capasso, L.; Caliendo, L.; Paolercio, F.; Rosa, N. IOL power calculation after corneal refractive surgery. Biomed. Res. Int. 2014, 2014, 658350. [Google Scholar] [CrossRef] [PubMed]
- De Bernardo, M.; Gioia, M.; Capasso, L.; Rosa, N. Comment on: Evaluation of choroidal thickness in amblyopia using optical coherence tomography. Eur. J. Ophthalmol. 2022, 32, NP324. [Google Scholar] [CrossRef] [PubMed]
- De Bernardo, M.; Altieri, V.; Coppola, A.; Gioia, M.; Rosa, N. Choroidal evaluation in patients under alpha-lytic therapy. Graefes. Arch. Clin. Exp. Ophthalmol. 2020, 258, 2729–2736. [Google Scholar] [CrossRef] [PubMed]
- De Bernardo, M.; Cione, F.; Capasso, L.; Coppola, A.; Rosa, N. A formula to improve the reliability of optical axial length measurement in IOL power calculation. Sci. Rep. 2022, 12, 18845. [Google Scholar] [CrossRef] [PubMed]
- Wang, L.; Shirayama, M.; Ma, X.J.; Kohnen, T.; Koch, D.D. Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J. Cataract Refract. Surg. 2011, 37, 2018–2027. [Google Scholar] [CrossRef] [PubMed]
- Wang, L.; Koch, D.D. Modified axial length adjustment formulas in long eyes. J. Cataract Refract. Surg. 2018, 44, 1396–1397. [Google Scholar] [CrossRef] [PubMed]
- Wang, L.; Holladay, J.T.; Koch, D.D. Wang-Koch axial length adjustment for the Holladay 2 formula in long eyes. J. Cataract Refract. Surg. 2018, 44, 1291–1292, Erratum in: J. Cataract Refract. Surg. 2019, 45, 117. [Google Scholar] [CrossRef] [PubMed]
- Hoffer, K.J.; Savini, G. Update on Intraocular Lens Power Calculation Study Protocols: The Better Way to Design and Report Clinical Trials. Ophthalmology 2021, 128, e115–e120. [Google Scholar] [CrossRef] [PubMed]
- Cione, F.; De Bernardo, M.; Capasso, L.; Rosa, N. Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery: Comment. Clin. Exp. Ophthalmol. 2021, 49, 87–88. [Google Scholar] [CrossRef] [PubMed]
- De Bernardo, M.; Cione, F.; Rosa, N. Re: Turnbull et al.: Methods for intraocular lens power calculation in cataract surgery after radial keratotomy (Ophthalmology. 2020;127:45-51). Ophthalmology 2020, 127, e87. [Google Scholar] [CrossRef] [PubMed]
- Ying, G.S.; Maguire, M.G.; Glynn, R.; Rosner, B. Tutorial on Biostatistics: Statistical Analysis for Correlated Binary Eye Data. Ophthalmic Epidemiol. 2018, 25, 1–12. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Cione, F.; Di Stasi, M.; Sannino, C. Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947. J. Clin. Med. 2023, 12, 2911. https://doi.org/10.3390/jcm12082911
Cione F, Di Stasi M, Sannino C. Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947. Journal of Clinical Medicine. 2023; 12(8):2911. https://doi.org/10.3390/jcm12082911
Chicago/Turabian StyleCione, Ferdinando, Margherita Di Stasi, and Ciro Sannino. 2023. "Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947" Journal of Clinical Medicine 12, no. 8: 2911. https://doi.org/10.3390/jcm12082911
APA StyleCione, F., Di Stasi, M., & Sannino, C. (2023). Comment on Moshirfar et al. Accuracy of Six Intraocular Lens Power Calculations in Eyes with Axial Lengths Greater than 28.0 mm. J. Clin. Med. 2022, 11, 5947. Journal of Clinical Medicine, 12(8), 2911. https://doi.org/10.3390/jcm12082911