Review

Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges

1
Department of Civil and Resource Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada
2
Ecosystem Science, Fisheries and Oceans Canada, Ottawa, ON K1A 0E6, Canada
3
School of Environment, Nanjing Normal University, Nanjing 210023, China
4
Northern Region Persistent Organic Pollution Control (NRPOP) Laboratory, Memorial University of Newfoundland, St. John’s, NL A1B 3X5, Canada
*
Author to whom correspondence should be addressed.
J. Mar. Sci. Eng. 2022, 10(9), 1313; https://doi.org/10.3390/jmse10091313
Submission received: 30 July 2022 / Revised: 9 September 2022 / Accepted: 10 September 2022 / Published: 16 September 2022
(This article belongs to the Special Issue Reviews in Marine Environmental Science and Engineering)

Abstract

:
Oily wastewater has been recognized as a threat to the environment due to its hazardous nature and it can negatively affect the ecosystem, and threaten wildlife and human health. Physical, chemical, and biological technologies demonstrated a mixed performance in oily wastewater treatment, and, therefore, a proper treatment technology for oily wastewater needs to be addressed. Membrane filtration using a hollow fiber (HF) membrane is a promising alternative to remove emulsified oil from oily wastewater. This review discusses different sources of oily wastewater, various treatment methods, and membrane technology. The assessment has been focused on the parameters affecting HF membrane performance and applications of HF membrane-based technology to treat oily wastewater. This review paper reveals that HF membrane filtration systems have been previously used for the treatment of oily wastewater in bench-scale studies and few pilot-scale applications, which proved to be favorable in the treatment of recalcitrant wastewater containing oil and high salinity. Limitations associated with membrane fouling and the reduction of membrane permeability and membrane lifespan can be tackled and alleviated through modifying membrane chemistry and adjusting operational parameters. The compilation of studies showed that a low food/microorganism (F/M) ratio, long solid retention time (SRT) with high sludge age, long hydraulic retention time (HRT), and moderate aeration were the preferred operational parameters when treating oily wastewater. Based on this review, future studies should focus on optimizing the hydrodynamic conditions of the HF system, the commercialization of modified HF membranes, and the utilization of green technology in HF membrane construction to broaden HF membrane technology applications.

1. Introduction

In the past two decades, different industrial sectors have generated large volumes of oily wastewater and discharged it into the environment [1,2,3,4]. Oily wastewater is characterized by high biochemical oxygen demand (BOD), total suspended solids (TSS), chemical oxygen demand (COD), ammonia, sulphides, total organic carbon (TOC), and total petroleum hydrocarbon (TPH), with their concentration varying depending on the operations and products from the manufacturing industries [5]. It also contains many toxic compounds, such as volatile organic compounds (VOCs) (e.g., benzene, toluene, ethylbenzene, and xylene (BTEX)), polycyclic aromatic hydrocarbons (PAHs), phenols, and heavy metals [4,6,7,8]. When oily wastewater is discharged into water bodies, land, and/or sewer lines without adequate treatment, it negatively affects drinking water and groundwater sources, wildlife, and human health, and also causes atmospheric pollution [9,10]. The global increase in the discharge of oily wastewater, and strict environmental regulations for effluent discharge, necessitate the need for effective and adequate oily wastewater treatment [5]. Previously, a variety of treatments, including physical, chemical, and biological methods have been widely used to treat oily wastewater and mitigate its environmental impacts [11]. However, physical methods require large space for installation, high energy for dispersing coagulants, long periods of time to separate oil using gravitational force, and a low treatment efficiency [3,6,9,12]. Chemical methods consume toxic compounds, have high chemical costs, generate secondary pollutants, and are not suitable for the environment [3,6,9,13]. The efficiency of biological methods is affected by changes in environmental factors such as the level of oxygen, temperature, and variation of feed composition. Oil compounds are highly toxic and have poor nutrients for microorganisms; and several compounds such as saturates, aromatic, asphaltenes, and resins cannot be decomposed efficiently using this method [13,14]. Therefore, the focus of researchers has shifted to emerging and advanced treatment technologies for sustainable, cost-effective, eco-friendly, and efficient treatment of oily wastewater [5].
Among all of the advanced methods, membrane-based technology is a promising method for oily wastewater treatment due to its capability in separating oil droplets smaller than 20 µm [15,16,17]. The membrane filtration technology has benefits such as high effluent quality, low requirement for chemical additives, low generation of sludge, and a small footprint [8,18,19]. Additionally, membrane technology has a low energy cost compared to conventional and other advanced technologies. Membrane filtration treatment does not have any moving parts, has the possibility of using intermittent aeration, and has low chemical substance usage, which contributes to its low energy requirement [20,21,22]. Hollow fiber (HF) is the desired membrane configuration for oily wastewater treatment as it has the highest surface area per unit volume, is mechanically self-supported, and can stimulate the movement of hollow fibers through air scouring, and backwashing, which helps mitigate membrane fouling [23,24]. This technology can either be used as a physical separation approach or integrated with a biological component (i.e., membrane bioreactor (MBR)) for treating oily wastewater [18,25]. The application of HF membranes for oily wastewater treatments is contingent on various factors such as membrane material, features, and operational factors such as flux, aeration flow rate, and activated sludge characteristics [26,27]. There needs to be a delicate balance between operational parameters to attain optimal membrane permeability, and, consequently, high effluent quality [28].
Although membrane-based technologies are dependable treatment systems, membrane fouling is a notable problem impeding widespread and large-scale applications of this technology [2,29]. Membrane fouling increases transmembrane pressure (TMP), which, in turn, reduces permeate production and decreases membrane lifespan. Consequently, frequent membrane cleaning and replacement are required, therefore, increasing operational costs [2,28]. Thus, further research is required for developing new methods for enhancing membrane performance.
The objective of this review paper is to investigate the application of HF membrane-based technology and identify its challenges in order to improve its performance in treating oily wastewater. The first section of this paper discusses the sources of oily wastewater and its treatment methods. The assessment then focuses on membrane-based technology, HF membrane characteristics, important parameters affecting its performance, and HF membrane applications in oily wastewater treatment. The paper explores recommendations to improve the treatment of oily wastewater using an HF membrane filtration system.

2. Oily Wastewater and Treatment Methods

2.1. Oily Wastewater Sources

Different industrial sources generate an immense volume of oily wastewater which adversely affects the environment, wildlife, and human health due to the existence of BTEX, phenols, and total acid and grease with quantities ranging between 0.73–24.1 mg/L, 0.001–10,000 mg/L, and 2–560 mg/L, respectively [30].
Food, metallurgical, petroleum, and transportation industries are among the significant sources of oily wastewater [4,31].
In the food industry, palm, soybean, olive, cottonseed, and sunflower are major sources of extracting edible oil. The global oil market is predicted to increase from 83.4 billion US$ (2015) to 130.3 billion US$ by 2024 with a compound annual growth rate (CAGR) of 5.1% [32]. Palm oil is the most common edible oil in the world with 37% of the total vegetable oil production [33]. During oil processing, a high volume of oily wastewater is generated (e.g., during the production of palm oil, 0.5–0.75 tons of palm oil mill effluent per one ton of fresh fruits were generated) [34]. This type of oily wastewater has a high concentration of COD, BOD, total dissolved solids (TDS), TSS, oil and grease, fats, phosphate, and sulphate [32].
Another significant source of oily wastewater is generated from the lubricating and cooling of metal pieces in machinery [35]. They are spilt into two categories, one is oil-based metalworking fluids (MWFs) and the other is water-based MWFs [36]. The waste generated as a result of using these MWFs is known as spent cutting oil [37]. On a global scale, more than 2,000,000 m3 of MWFs are used annually, however, the volume of wastewater can be ten times higher because of the dilution of MWFs [36]. MWF is comprised of heavy metals, acids/alkalines, radioactive metals, phenols, PAHs, hydrazines and imine-carbohydrazides, and thiophenes as well as hydrocarbons containing BTEX which are persistent in the environment [38].
Oily wastewater is generated from every step of the petroleum industry including exploration, drilling, processing, and storage, with the wastewater produced from these processes referred to as produced water [4]. Among them, oil drilling and oil refinery processes produce the largest amount of oily wastewater [39]. For instance, the total amount of produced water globally generated from the petroleum industry is 39.746×109 L/d [9]. The characteristics of the produced water are varied depending on the location of the refinery and oil well [4,31]. Petroleum wastewater contains a complicated mixture of oil, water, and suspended and dissolved solids. PAHs, phenols, heavy metals, and radioactive elements are among the most concerning components [16,40,41,42]. Marine transport is a major source of oil pollution; the emergence of the worldwide shipping industry increased illicit discharge of bilge and ballast water and oil spill disasters [11]. For instance, the International Tanker Owners Pollution Federation (ITOPF) recorded the largest volume of oil spilled in the past 24 years (i.e., SANCHI, off the coast of China) occurred in 2018, releasing ~98,000 tonnes of oil [43]. In addition, the oil spill volume for 2021 is the second highest estimate (i.e., ~82,000 tonnes) in the last ten years globally as a result of six oil spill incidents [43]. Harmful compounds that are released in the water as a result of a spill include hydrocarbons, hazardous metal ions, detergents, surfactants, and petroleum products, such as crude oil, diesel oil, gasoline, lubricant, and kerosene [11].

2.2. Treatment Methods

Different types of treatment have been used to separate oil from oily wastewater including physical, chemical, and biological methods [44,45]. A suitable treatment technology is selected based on the source of wastewater, wastewater characteristics, operational cost, and the end-use of effluent [4,5].

2.2.1. Physical Methods

Physical treatment methods include gravity separation, dissolved air floatation (DAF), coagulation, and membrane separation which are used to treat oily wastewater [11,46,47,48]. The gravity separation method is operated based on the difference in densities of hydrocarbons and water phases, this method is suitable for removing suspended solids (SS) and free oil (i.e., oil–water mixture with droplet diameters >150 μm) [49,50]. Gravity separation is usually used as a pre-treatment or primary treatment; since this method is incapable of separating dispersed oil (i.e., oil droplet size ranging between 20 and 150 μm) or emulsified oil (i.e., droplet size of smaller than 20 µm) [51]. In this approach, gravity as the driving force is very slow, incomplete, and time-consuming in many situations [51].
Compared to gravity separation, DAF is a faster technology and has a smaller footprint. DAF can effectively separate dispersed and emulsified oils, using gas bubbles that are introduced into the oil-containing liquid which sticks to the oil droplets. The gas bubbles quickly rise to the surface demulsifying the solution; the oil layer on top is then removed [52]. Previous studies showed that increasing oil concentration and flow rate decreased the oil removal efficiency in DAF. Increasing the flow rate into the DAF tank can cause the oil droplets to flow straight to the effluent without having much time to attach to the air bubbles and float to the surface [47,53]. Increasing the pH range decreases the oil removal efficiency since it increases the repulsion between the oil and water surface and hinders oil droplets from attaching to the air bubbles in the clarifier due to the absorption of (OH) ions at the oil–water interface [53,54]. Increasing the temperature of the oil-in-water mixture decreases the viscosity and the surface tensions which increases the separation rate of oil and water [55,56]. Due to the continuous generation of air bubbles, DAF technology has the disadvantage of high energy consumption [6].
Another technique, coagulation, is often used prior to DAF [57,58]; the coagulation mechanism is based on using coagulants to destabilize the colloids through the neutralization of the repulsive forces between the fine colloids [11,59]. This method is capable of removing emulsified and dispersed oils in addition to some difficult to biodegrade organic polymers [60]. Previous studies used different types of coagulants such as poly-zinc silicate, polyaluminum chloride, polyferric sulphate, polyferricsilicate sulphate, and chitosan to remove oil efficiently [61,62,63,64]. Parameters such as molecular weight, dosage, and charge density of coagulants determine the coagulation efficiency [65]. The coagulants with a low molecular weight capable of neutralizing the negative charge on the oil droplet have been commonly used [66]. Studies showed that a low coagulant dosage is not adequate to destabilize all of the colloidal particles and increasing the coagulant dosage increases the oil removal efficiency. However, when the dose of coagulants saturates the solution, there is a decreasing trend in the oil removal efficiency [67]. Coagulants with higher charge density demonstrated good results in oily wastewater treatment, for example, polyaluminum chloride with a high charge density showed an excellent result in oily wastewater treatment because the flocs were large and dense during the coagulation process [68]. Although coagulation is an effective process, it has some drawbacks such as requiring a large amount of coagulants that are hazardous to the environment, causing corrosion problems when pH is reduced, and the generation of sludge that needs further treatment [60].
The membrane filtration system overcomes the weaknesses of other methods in terms of a prolonged process, large-space requirement, high amount of waste generation, and low treatment efficiency [3,6,16]. The membrane technology utilized for oily wastewater treatment is driven by pressure. The membrane pore size acts as a selective barrier allowing the smaller particles to pass through, while the larger-sized oil particles are blocked and retained in the feed solution [69,70]. This method is an excellent approach for the treatment of oily wastewater, particularly for effluents containing emulsified oil with minimal density difference in comparison with water [16,71,72]. The summary of physical treatment methods in terms of advantages and disadvantages is shown in Table 1.

2.2.2. Chemical Methods

Advanced oxidation process (AOP), adsorption, and demulsification are categorized as chemical treatments [77,78,79,80,81,82,83]. The AOP is described as the method that relies on the production of hydroxyl free radicals, which has great electrochemical oxidant power and strong oxidizing potential. Their excellent oxidizing potential allows them to easily degrade organic compounds (i.e., oil) converting them to H2O, carbon dioxide (CO2), and inorganic ions, through dehydrogenation or hydroxylation [84,85]. There are three main types of AOP, such as electrochemical oxidation, Fenton process, and photocatalytic treatment which are commonly used in oily wastewater treatment [59]. The advanced oxidation methods are associated with high mineralization efficiency, rapid oxidation reaction rates, and minimal toxicity, which are favorable in the treatment of oily wastewater [86,87]. For instance, Gotsi et al. [88] investigated the treatment efficiency of the wastewater generated from olive oil mills using electrochemical oxidation. In this study, a flow-through electrolytic cell with internal recycling at a voltage of 5, 7, and 9 V, NaCl concentrations of 1%, 2%, and 4%, recirculation rates of 0.4 and 0.62 L/s, and initial COD concentrations of 1475, 3060, 5180, and 6545 mg/L were examined. Results showed that increasing voltage, salinity, and recirculation rates led to a high oil removal efficacy. In photocatalytic research, previous studies mostly used TiO2 and ultraviolet and/or solar light for oil degradation [89,90]. These studies showed good results when oxidizing PAHs, BTEX, and phenols in oily wastewater [81]. In this line, Sivagami et al. [91] examined the treatment of total petroleum hydrocarbons in oil spill sludge using the combination of ultrasound and the Fenton process. Different operating parameters such as pH, ultrasonic power, the weight ratio of hydrogen peroxide to iron [H2O2/Fe2+], Fenton reagent dosage, addition of salts, and contact time were investigated. The high petroleum removal efficiency (84.25%) was obtained at a pH of 3.0, sludge/water ratio of 1:100, ultrasonic power of 100 W with 40–50% ultrasonic amplitude, an H2O2/Fe2+ weight ratio of 10:1, and an ultrasonic treatment time of 10 min. While Liu et al. [81] investigated the treatment of offshore produced water using a photocatalytic ozonation system with TiO2 nanotube arrays (TNA) and UV-light-emitted diode (UV-LED) irradiation. Results showed that ozone significantly improved the oxidation rates and removed the PAHs within 30 min. However, the high cost of the treatment process, high energy consumption, corrosion problems in treatment facilities, harmful and toxic catalysts, solid waste generation, and complex chemistry are the downsides of AOPs [87,92].
The adsorption method refers to the physical adhesion of the polluting chemicals onto the surface of a solid, which is used to eliminate soluble oil and chemically stable emulsions [93]. In this method, a wide range of materials such as activated carbon, bentonite, sand, coal, polypropylene, and organoclay are used. In this line, Okiel et al. [94] investigated the treatment of oily wastewater using bentonite, powdered activated carbon, and deposited carbon. The impacts of contact time, adsorbent weight, and the concentration of adsorbate on the oil removal were examined. The oil removal efficiency was improved by increasing the contact time and the adsorbent weight. Deposited carbon and bentonite had higher adsorptive capacities compared to the powdered activated carbon. Deposited carbon and bentonite have a higher porosity and surface area; therefore, they are more suitable for oil removal. In another study, Islam [95] investigated the efficacy of organoclay to remove the oil by measuring its adsorption capacity. It was found that organoclay was effective in removing different concentrations of oil in the oily wastewater. The contact time of 3 h between organoclay and the oil-in-water emulsion was optimal for high oil removal efficiency. The oil removal efficiencies for initial oil concentrations of 750 ppm, 1000 ppm, and 1500 ppm were 28.20%, 35.75%, and 40.036%, respectively. Although adsorption is an effective treatment, the preparation of adsorbents is time-consuming, complicated, and expensive; additionally, as the adsorbent is used there is a reduction in the active ingredient percentage, mechanical strength, and adsorption selectivity, which restricts its application [11,96].
Chemical treatment with demulsifiers (surface active agents) is also used to treat oil-in-water emulsions as the chemical additives accelerating the separation of oil and water [97]. When demulsifiers are used, they move to the water and oil interface, weakening the surface tension and improving coalescence. This method is rapid, efficient, and capable of decreasing oil viscosity in an emulsion and separating oil and water [98,99]. Previous studies showed that the demulsifier’s molecular weight had a significant impact on the performance of demulsification. Increasing molecular weight resulted in better separation and there was a linear correlation between the removal efficiency and the molecular weight [100,101]. Razi et al. [102] investigated the impact of various demulsifier formulations on the efficacy of chemical demulsification of heavy crude oil. Results demonstrated that the different surfactant demulsifiers varied in removal efficiency. The formulated surfactant showed a higher efficiency in the demulsification of a medium crude oil emulsion compared to a heavy crude oil emulsion. The different surfactant efficiencies were associated with asphaltene content which was lower in the medium crude oil. Different studies reported the use of demulsifiers formulated from polymers, such as alkene oxides diester, ethylcellulose (EC), Tween non-ionic polymer, and polyester to improve the efficiency of oil removal [103,104,105]. As an example, the demulsification efficiency of 97.5% was reported within 45 min of the demulsification process using a polyester-based demulsifier. Demulsification mitigates the requirement for heating and retention time for the separation process [98]. The overdose of demulsifiers negatively impacts treatment efficiency by forming a rigid layer caused by aggregating particles; therefore, adding the ideal amount of demulsifier during oily wastewater treatment is required to enable propagation expansion at the interface when it is dissolved in the oil phase [82,99]. Table 2 shows the advantages and disadvantages of chemical methods and the types of oil that can be removed.

2.2.3. Biological Methods

In the biological treatment method, different types of microorganisms are cultured and used to degrade the organic contaminants in wastewater [69]. The microbes use organic matter such as oil as a source of carbon along with sources of phosphorus and nitrogen as nutrients to perform metabolic processes. As a byproduct of microbial metabolism, the oil contaminants are converted to less harmful products such as carbon dioxide, methane, oxygen, and nitrogen gas [109]. Biological studies used activated sludge to treat oily wastewater [9,110,111,112]; for instance, Shokrollahzadeh et al. [111] achieved 89% and 80% COD and total hydrocarbon removal, respectively, when treating petroleum wastewater. In another study, Sanghamitra et al. [9] reported the removal efficiency of oil ranging from 54.6–80% using an aerobic batch reactor for the treatment of oily wastewater.
Using the biofilm method, layers of microorganisms are grown on a filter material. When the microbes contact raw water, they begin to biodegrade the organic contaminants in the wastewater [11]. The advantages of this method include eco-friendliness, compatibility with carbonaceous stabilization, and it has a cheap and straightforward operation [9]. Sun et al. [113] studied the biofilm-MBR technology used to treat shipboard wastewater. Two processes such as dead-end sidestream and recycle sidestream configurations of a biofilm-MBR were used. A membrane permeate quality of less than 5 mg/L oil was obtained in each process configuration. In this research, a remarkably enhanced membrane performance and better quality of permeate were obtained by recycling the concentrate solution back to the biofilm reactor because of better bio-flocculation and biodegradation of oil compounds in the process. In another study, the impact of biofilm formation on membrane performance was assessed in an MBR unit treating petrochemical wastewater. The biofilm formation in the MBR system enhanced COD removal efficiency by up to 95% [114]. Biological methods have difficulty handling various microbial behaviors under different environmental conditions [69]. The advantages and disadvantages of biological methods are presented in Table 3.
Reviewing the benefits and drawbacks of different physical, chemical, and biological processes demonstrated the characteristics of each technology that need to be considered when selecting a suitable approach to treating oily wastewater. Membrane technology, either in the form of physical separation or MBR, is a suitable solution to treat oily wastewater compared to other methods since it has a selectivity feature, small footprint, high volumetric loading rate, and high effluent quality [3,6,16]. It is important to consider different aspects of membrane technology such as material, fabrication method, and configuration to improve oily wastewater treatment.

3. Membrane-Based Technology

3.1. Membrane Fabrication

When a membrane module is in a direct contact with oily wastewater, the membrane materials should sustain integrity for a long period of time and maintain a good performance based on its chemical resistance, mechanical strength, durability in a wide range of pH levels, heat resistance, hydrophilicity, surface roughness, and its membrane flux [11,115]. Therefore, an important aspect in the preparation of membranes with high efficacy is the specification of a suitable fabrication method and membrane material [116].
The preparation of the membrane is dependent on the required morphology [116]. Some universal methods for membrane preparation to improve performance are phase inversion, interfacial polymerization, stretching, and electrospinning. Polymeric membranes designated for oily wastewater treatment are often prepared using phase inversion or electrospinning [116]. The phase inversion method is a simple and straightforward technique for preparing a membrane [117]. In this process, the thermodynamic state of a homogeneous polymer solution is altered by contacting it with another phase (liquid or vapor), this will improve the formation of a solid phase. This is a common method for the production of microporous polymeric membranes [118]. In contrast to the phase inversion, electrospinning leads to membranes with a relatively uniform pore size distribution with high interconnectivity of pores and significantly higher porosity [119]. Electrospinning continually generates ultrathin polymer fibers of nano to micrometer sizes. Electrospun membranes include a nonwoven and persistent web of nanofibers with an intricate pore structure [120]. The electrospinning method has a simple and versatile instrument and is a continuous, scalable, and cost-effective process [121]. However, the use of organic solvents in the electrospinning method is harmful to the environment and human health [121,122].
Commonly used polymers for membrane material are polyvinylidene difluoride (PVDF), polyethylene (PE), polyacrylonitrile (PAN), and polytetrafluoroethylene (PTFE) [116,123]. Polymeric membranes are hydrophobic, hence they are prone to high rates of membrane fouling, therefore, prior to use, the membranes are typically modified [116]. Polymeric membranes can be enhanced by membrane surface modifications with hydrophilic polymers or by coupling diverse manufacturing techniques to improve the membrane performance. The resulting hydrophilicity not only helps prevent the oil droplets from blocking the membrane surface and improving the treatment efficiency but also saves a significant amount of cost in membrane maintenance and replacement [26,117,124].
The main surface modification methods are surface coating and surface grafting of the membrane [124]. Surface coating is an economical practice for membrane functionalization and can be easily implemented in industrial-scale operations. The coating acts as a protective layer against the harsh oily wastewater environment to prolong membrane life [123,124,125,126,127]. There are different techniques involved such as sulfonation or cross-linking that are used to secure the coating on the membrane surface. Surface grafting forms covalent bonds on the surface of the membrane with new functional groups [123,124]. This type of surface modification also has the potential to expand or shrink membrane pore size. Surface grafting is achieved through chemical processors with high-energy radiation or UV irradiation. The hydrophilicity of the surface is accomplished by grafting polar functional groups on the membrane surface [123,124,128,129]. When the membrane surface is modified, the charge on the surface of the membrane is designed to be the same charge as the foulants in the wastewater that it is treating, resulting in repulsive electrostatic forces to reduce fouling [130,131]. Inorganic nanoparticles such as SiO2, Al2O3, clay, ZrO2, TiO2, and ZnO are often used to enhance polymeric composite membranes, and increase thermal stability, permeation, and antifouling properties [23].

3.2. Membrane Selectivity

The separation efficiency of the membranes depends on their selectivity since membranes are semi-permeable barriers through which selectivity between species can be obtained to allow for the separation between unwanted and wanted particles. They will allow the passage of desired species and block the passage of undesirable ones [115]. To achieve selectivity, membrane pore size must be carefully chosen [115,132]. The type of wastewater to be treated dictates the best membrane pore size to be used [26]. Based on the molecular weight cut-off (MWCO), membrane filtration is divided into microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) [133]. The largest pore size ranging from 100–1000 nm belongs to MF which is capable of separating suspended solids and bacteria through the mechanism of convective pore flow [134]. The pore size of UF is smaller than that of MF ranging from 5–100 nm. UF can be used in the filtration of color, viruses, aroma, and colloidal organic substances [135]. NF has a pore size of 1–5 nm, leading to higher organics removal than UF membranes [134,136]. RO is characterized by a pore size of 0.1–1 nm and is capable of removing salinity from wastewater [137]. MF and UF membranes have been extensively reported for oily wastewater treatment, and, among these membranes, UF is the most favorable due to a low-pressure operation, and low capital and operating costs [10].

3.3. Membrane Configuration

Configuration is another factor that influences the application and effectiveness of the membrane when treating oily wastewater. Membrane configuration refers to the geometry of the membrane and its position in space in relation to the flow of the feed fluid and the permeate. As most industrial membrane installations are of modular design, membrane configuration also determines the manner in which the membrane is packed inside the modules [138]. The desired characteristics of a membrane configuration include compactness (i.e., the capability of packing as much membrane surface as possible into a module), low resistance to tangential flow (i.e., low friction and energy consumption, low-pressure drop along the retentate flow channel), uniform velocity distribution, easy cleaning and maintenance, and low cost per unit membrane area [138].
Two process configurations in membrane technology are submerged and sidestream which are used in the treatment of oily wastewater [139,140]. In the submerged type, the membrane is located inside the membrane tank while in the sidestream, the membrane is placed outside the membrane tank [141]. Submerged configuration is easy to operate and needs low energy compared to the sidestream setup, however, the cleaning process in the submerged is more complicated than that of the sidestream [142]. Three strategies can be used in submerged processes to limit fouling, such as increasing the aeration flow rate, decreasing the membrane flux, and using physical or chemical cleaning. Aeration produces a shear force on the membrane surface through the rise of coarse bubbles which mitigates the accumulation of foulants on the membrane surface. Using lower membrane flux limits membrane fouling since it decreases the rate of foulants reaching the membrane surface. Implementing the mentioned strategies mitigates the need for membrane cleaning. Using physical cleaning is more straightforward than chemical cleaning since chemical cleaning requires chemicals and generates chemical waste. Often, physical cleaning is enough to remove the foulants on the surface of the membrane (reversible fouling). Chemical cleaning is seldom needed and is mainly used to unclog the pores of the membrane (irreversible fouling) [143,144].
In the sidestream configuration, the mixed liquor from the bioreactor is circulated on the membrane surface at high crossflow velocities and pressures, requiring high energy demand to mitigate membrane fouling [145]. This configuration, however, experiences more severe membrane fouling than submerged membranes due to the lack of sufficient shear force on the membrane surface. Aeration is much more effective at producing a high shear force on the membrane surface than circulating mixed liquors at high crossflow velocity [144,146].
There are four main membrane configuration categories, such as plate and frame, tubular, spiral wound, and HF. The plate and frame is one of the earliest modules produced [142] which contains two flat-sheet membranes that are stretched across a thin frame. There is a vacuum space between the two membranes, which supplies the driving force for filtration. Many plates are organized in a cassette to expand the surface area. The flow for the immersed cassette is designed to be from the outside-in (i.e., the air stimulates liquid to be crossflow along the plates). This configuration has a limited application and is mostly used for treating wastewater with high amounts of SS [142]. The process generates turbulence and hampers cake formation, and, therefore, reduces membrane fouling. The crossflow of air helps dissolve oxygen in the membrane tanks and mixes wastewater in the reactor [147,148,149]. The packing density of plate and frame ranges between 148–492 m2/m3 which is lower than spiral wound and HF. This membrane has a moderate potential for membrane fouling, and its cleaning is easier than spiral wound and HF, however, its manufacturing cost is high.
The tubular membrane contains outer housing (i.e., shell) which is tubular. A perforated or porous stainless steel or fiberglass pipe is placed within the tubular shell, and a semi-permeable membrane is inserted within the stainless steel or fiberglass pipe. The permeate passes through the pipe into the inside of the housing and is collected by the permeate outlet [138,142,150]. The packing density of the tubular membrane is between 20–374 m2/m3 which is the lowest compared to other configurations. This type of membrane maintains a high tangential velocity in the feed and is used for feed containing a high amount of SS [138,142]. This membrane has a low potential for membrane fouling and its cleaning is the easiest due to the large diameter, however, its manufacturing cost is high [138].
Spiral-wound membranes are comprised of the membrane, feed spacers, permeate spacers, and a permeate tube. Wastewater moves tangentially across the flow channel along the length of the spiral-wound membrane. The water will cross the membrane surface, rejecting larger particles, through the permeate spacer, and into the permeate tube. The permeate will exit at the other end of the spiral-wound membrane and into a separate tank [151,152]. The packing density of the spiral wound is 492–1247 m2/m3 which is lower than HF. This membrane has a high potential for membrane fouling, is hard to clean, and has moderate manufacturing costs [142].
HF membranes are made up of long threads or fibers of hollow membranes. The tubes are thin with diameters ranging from 1 mm down to capillary size. The membranes are installed on a supporting structure that functions as a manifold for permeate transport and a system for air distribution. Similar to the plate and frame module, HF relies on aeration to avoid excessive cake layer formation on the membranes. This type of membrane generally functions in an outside-in manner, where the fibers have a vacuum and the water flows from the reactor to the inside of the hollow fibers and out of the system [138,147]. This configuration is capable of housing large membrane areas in a single module. The packing density of HF is 492–4924 m2/m3 which is the highest and the manufacturing cost is low [142]. Table 4 shows the comparison of different membrane configurations.

4. HF Membrane Module and Its Performance Parameters

HF membrane application has caught a great deal of attention because they are able to separate and treat a wide range of complex wastewater, such as oily wastewater [139,160,162,163,164]. HF membranes are desired over other membrane configurations because they are compact modules with very high membrane surface area, high packing density, the feasibility of backwashing, self-supporting structure, simplicity of handling, and low manufacturing cost [23,24,142,149,165]. Three typical fiber packing configurations used for full-scale submerged HF membrane modules are the curtain fiber bundle, cylindrical fiber bundle, and cylindrical bundle with free fiber end, as shown in Figure 1. The most common module packing configuration is the curtain-type fiber bundle. This sort of packing configuration generally consists of 4 to 12 fiber sheets and permits well-defined fiber spacing and high tank packing density [166]. The cylindrical fiber packing configuration can attain high module packing density; however, the general tank packing density is typically less than the curtain type modules. The cylindrical with the free fiber end configuration can only be permeated from one end of the module, which could consequently increase the non-uniform distribution of TMP along the fibers, specifically when small-diameter fibers are used. Modules with the same packing configuration are compiled into a cassette to create an engineering module unit with a common permeate collection conduit to increase packing density, and, consequently, the productivity of a membrane tank [166].
Since membrane fouling is a major issue in membrane filtration technology, it is required to investigate the main parameters affecting fouling in HF membranes. Membrane properties (i.e., fiber diameter, length, and tightness), hydrodynamic conditions (i.e., surface shear, air flow rate), feed properties (i.e., foulant properties, concentration, viscosity), and operating conditions (i.e., temperature, membrane flux) affect the membrane performance [23]. Previous studies showed that low membrane fouling is a result of a low HF packing density, through having few fibers, widening the HF module, and changing the module configuration [167,168]. In addition, designing modules with improving lateral flow or lateral movement of the fibers can enhance the submerged HF systems [169]. Yeo and Fane [167] concluded that a single fiber operated better than a multi-fiber HF module in the absence of aeration because of module blocking. However, fiber movement as a result of aeration is another factor that affects the fouling deposition on HF membranes. Bérubé and Lei [170] reported that a multi-fiber module outperformed a single fiber in the presence of aeration due to inter-fiber interactions which cause mechanical erosion of the foulant layer. Pourbozorg et al. [171] studied the effect of vibration induced by perforated plates on the fouling reduction of submerged HF membranes. Results showed that the fouling rate was dependent on kinetic energy and eddy length scale; greater turbulence kinetic energy resulted in a lower fouling rate.
Higher fiber movement obtained by using looser fibers improves the back-transport of the foulants from the membrane caused by physical contact among the fibers, decreasing membrane fouling [172,173]. A study reported that tight fibers in HF led TMP to increase 40% faster compared to fibers with a 4% looseness [174].
Previous experimental studies showed that a smaller HF diameter enhanced the performance of submerged systems as a result of higher fiber mobility under aeration [172,174,175]. In addition, long fibers (i.e., length in the range of 0.3–1 m) reduced membrane fouling due to non-uniform deposition of particles and high movement due to aeration [176,177]. Recently, Khanafer and Assad [178] reported that the increase in fiber length from 1 to 1.5 m led to an increase in permeate productivity by approximately 248%. They concluded that fiber length and inner radius should be optimized to enhance productivity and filtration uniformity in HF systems.
In terms of hydrodynamic conditions, crossflow velocity, aeration, and vibration in submerged HF systems impact surface and unsteady-state shear which affect membrane fouling and performance [179,180,181,182] Previous studies concluded that aeration intensity enhances the hydrodynamics of the membrane filtration system; air bubbles change the structure of the fouling layer, and decrease specific resistance [181,183]. Selecting an optimum airflow rate was crucial for treatment efficiency; a higher aeration flow rate than the critical value has shown to have no effect on system performance [184,185]. The position of aerators in the HF membrane filtration system was also studied and results showed that the injection of air at the bottom of the membrane fiber enhanced the overall system performance [186].
In MBR technology, parameters such as food-microorganism (F/M) ratio, SRT, HRT, and aeration flow rate have a significant impact on HF membrane performance. The operational parameters have a substantial effect on microbial extracellular polymeric substance (EPS) and soluble microbial products (SMP) production. EPS is defined as an extracellular polymeric substance of biological origin that participates in the formation of microbial aggregates [187]. SMP is a soluble microbial product that is comprised of hydrolysis products of EPS and decay products of active cells [188].
For microbes to effectively biodegrade hydrocarbons a balance between food entering the bioreactor and the microbes in the bioreactor is necessary. With a high F/M ratio, the bacteria are scattered within the bioreactor and reproduce quickly as a result of having more food than microorganisms in the enclosed environment. Due to the dispersion of bacteria, large flocs are unable to form, leading to poor settling [189]. Additionally, at high F/M ratios, an increase in membrane fouling occurs due to high food utilization by biomass resulting in increased EPS and SMP production [190,191,192]. As an example, Dvořák et al. [193] investigated the impact of the F/M ratio on membrane fouling and EPS production. Results showed that a high F/M ratio led to a high concentration of EPS. The high F/M ratio disturbs the balance between the food supply and the mass of microorganisms in the system, leading to higher metabolic activity and microbial growth [191,192].
At low F/M ratios, the food supply is restricted, resulting in the bacteria producing a thicker slime layer, losing their motility, clustering together, and forming large flocs that settle easily. At high sludge age and mixed liquor suspended solid (MLSS) concentration, the system demands fewer nutrients, owing to the decrease in excess sludge production. The MBR system reaches an equilibrium where the nutrient provided matches the microbial maintenance demand [189,194]. Therefore, it is favorable to use a low F/M ratio to mitigate membrane fouling.
SRT is the amount of time that the sludge is retained in the membrane bioreactor [139]. The key to effective wastewater treatment is to maintain a high MLSS concentration as a result of high sludge age. A high sludge age can be attained through long SRT, which allows the retention of particulate, colloidal, and higher-weight organics, giving the microbes maximum chance to degrade organic compounds, and allows for the acclimation of microbes to the biodegradable compounds [189]. However, extremely high SRTs are not desirable as they increase membrane fouling due to the accumulation of biomass (high MLSS) and increasing sludge viscosity [190], therefore, it is important to periodically discharge some of the activated sludge to maintain desired conditions within the membrane bioreactor [195]. Low sludge age and high SRT exert high stress on the bacterial community, resulting in high EPS and SMP production [180].
HRT is the amount of time that the wastewater remains in the bioreactor for biological degradation [57]. Long HRTs allow for a longer contact time of the microbes with the organic compounds in the wastewater; thus, increasing the removal efficiency of the contaminant and COD in the wastewater. However, long HRT is only effective provided that the MBR system is conducted under steady-state conditions (i.e., the microbial community is acclimated to the wastewater and high sludge age is achieved) [189]. Short HRT increases the organic loading rate, which puts a stain on the bacteria. The bacteria then produce excess EPS and SMP which contribute to membrane fouling and membrane flux decline [189,190]. The optimal HRT is dependent on the types of bacteria in the activated sludge and wastewater characteristics [190]. For example, Yang et al. [169] tested HRTs of 1, 2, 4, and 8 h to treat real domestic wastewater in a membrane filtration system. The HRT of 8 h had the best COD removal efficiency and had the lowest rate of TMP increase resulting in the lowest COD removal efficiency as well as the highest rate of TMP increase. Razavi and Miri [139] studied the treatment of HF-MBR to treat real petroleum refinery wastewater and tested HRTs of 25, 30, and 36 h. They concluded that the lowest removal efficiency and highest membrane fouling were obtained at HRT of 25 h and the best membrane performance occurred at HRT of 36 h.
Aeration provides oxygen to microorganisms, offers a homogenous distribution of activated sludge and fluid, and decreases fouling on the surface of the membrane [196]. Deng et al. [197] showed that increasing aeration changed the total quantity and composition of SMP [198]. Meng et al. [199] investigated the impact of different aeration flow rates such as 150, 400, and 800 L/h on membrane fouling in three MBR systems. The results showed that at a high aeration flow rate (800 L/h) colloids and solutes were the dominant foulants because of the breakup of sludge flocs. Using a moderate aeration flow rate was suggested to keep the sludge flocs intact so as not to disturb the sludge filterability, thus, resulting in a decrease in membrane fouling and an enhancement of membrane flux [200].

5. The Application of HF Membrane in Oily Wastewater Treatment

HF membrane has been used in two ways including physical separation and the integration of physical separation and biological method (MBR). The first section focuses on research works that solely use HF membrane filtration, and the second section reviews MBR for the treatment of oily wastewater. The selected studies will help us to understand the strengths and weaknesses of HF membrane technology, and the knowledge gaps in this field. The chosen studies were among the most highly-cited published HF research works, focusing on oily wastewater treatment.

5.1. Physical Separation Studies

Membrane surface modification is an effective method for improving membrane performance. Membranes are modified to be more hydrophilic; a higher affinity of water to hydrophilic membrane surface can lead to the development of a hydration layer on the membrane surface, which decreases membrane fouling by preventing hydrophobic components, such as oil, from attaching to membrane surface [163]. For example, Zhu et al. [163] constructed a new HF membrane using dry-wet spin phase inversion and modified it with hydrophilic and oleophobic surface features through blending a polymer, P(VDF-co-CTFE)-g-PMAA-g-fPEG, with a PVDF membrane to treat oily wastewater containing hexadecane, crude oil, and palm oil. The oil contact angle of the unmodified membrane was approximately 15° or lower which showed the high oleophilicity of the membrane while modified membranes had an oil contact angle of about 75° indicating a higher oleophobicity. Therefore, an unmodified membrane adsorbed a higher concentration of oil compared to a modified membrane due to its hydrophobicity. Results showed that the flux decline of unmodified membranes reached about 88% but modified membranes were at around 17%. The modified HF membrane had a greater water flux (i.e., 72 L/m2·h) during oily wastewater treatment. The flux recovery rate of the unmodified membrane after cleaning with deionized water was 40%, while the flux recovery rate of modified membranes was more than 89%, which was attributed to the oleophobic property. In addition, more than 98%, 98%, and 70% oil removal efficiencies for oily wastewater containing hexadecane, crude oil, and palm oil were achieved, respectively.
Luo et al. [201] used a novel sulfonated polyphenylenesulfone (PPSU) polymer with a super-hydrophilic feature to fabricate triangle-shaped tri-bore HF-UF membranes using a dry-jet wet-spinning process. Three membranes, polyphenylenesulfone, sulfonated polyphenylenesulfone with sulfonation degree of 1.5 mol%, and sulfonated polyphenylenesulfone with sulfonation degree of 2.5 mol% were compared. The oil contact angle for the unmodified membrane was 89.6° while for modified membranes with a sulfonation degree of 1.5 mol% and 2.5 mol% were 111.9° and 115.69°, respectively. This indicates that the modified membranes were more hydrophilic than the unmodified ones. Results showed that the unmodified membrane had a permeate flux decline of 82.1% and the total resistance increased by 5.7 times, while in modified membranes, the permeate flux decline was less than 55% and the total resistance increased only by 1.7–2.2 folds. The membrane with 1.5 mol % showed the highest flux and all membranes had 95.4% of TOC removal efficiency.
Otitoju et al. [202] compared three different membranes under the same operating conditions. The three membranes were PES, PES/SiO2, and tetraethyloxysilane PES/(TEOS). All the membranes were prepared using dry-wet spinning. The oil contact angle of the PES/TEOS membrane was 125.47° which was the highest compared to PES and PES/SiO2. PES/TEOS showed the best hydrophilicity compared to the other two membranes due to the formation of a large-scale network of Si-OH or hydroxyl groups originating from TEOS on the membrane surface. The PES/TEOS membrane had a 99.98% oil removal efficiency and a permeate flux of 90.937 L/m2·.h, while PES/SiO2 had an oil removal efficiency of 97.48% and permeate flux of 74.856 L/m2·h, and PES had an oil removal efficiency of 95.77% and permeate flux of 60.112 L/m2·h. Therefore, the unmodified membrane (PES) had the lowest oil removal efficiency and permeate flux compared to the modified membranes. This study also found that the modified PES/TEOS membrane showed exceptional antifouling properties and the oil deposition on it was easily washed through physical cleaning.
The blending of the main polymer with a hydrophilic polymer in the casting solution is a significant alternative, decreasing the fabrication cost compared to the other surface modification methods. In this line, Johari et al. [164] treated oily wastewater using fabricated HF membranes (i.e., a combination of hydrophilic polyamide imide (PAI) with three ratios of sulfonated poly (ether ether keton) (SPEEK)) through a phase inversion process. The oil contact angles in the unmodified membrane and modified membranes such as PAI/SPEEK 95/5 and PAI/SPEEK 85/15 were 105.7°, 111.7°, and 121.82°, respectively. This showed that the modified membranes were more hydrophilic than the unmodified ones. Results showed that oil removal efficiency was over 95% and the modified membrane showed a permeate flux of 39.6 L/m2·h which was 2.5 times the original membrane flux. Shen et al. [203] prepared a hydrophilic HF membrane with an antifouling feature by grafting sulfobetaine methacrylate (SBMA) onto polysulfone (PSU). The tests were conducted for six different types of oils, soybean oil, olive oil, lard oil, gasoline, diesel oil, and crude oil. The oil contact angle of the modified membrane was more than that of the PSU membrane which showed a better antifouling feature of the modified membrane. The modified membrane had a higher flux for oil/water emulsion of two vegetable oils (130–220 L/m2·h) than the original membrane. When oil concentration was at 1000 mg/L, the oil removal efficiency was over 91.1%. The flux was completely recovered after cleaning the membrane. This new method of membrane fabrication can operate efficiently to remove different oil compounds in wastewater.
El-badawy et al. [204] treated oily wastewater containing crude oil using PVDF-PET braid-reinforced HF membranes created with very thin and uniformly coated hydrophilic/oleophobic material through a dry-jet wet spinning process. Results showed that the flux reached 620 L/m2·h and oil removal efficiency was 88% due to high porosity and underwater oleophobicity. The modified membrane showed excellent antifouling features against wastewater containing crude oil with a high flux recovery of more than 95% for three filtration cycles.
Since producing a hydrophilic membrane is costly, membranes that are fabricated from low-cost and green materials and have promising results in terms of oil/water separation are desired. Baggio et al. [205] developed amphiphilic membranes from polyethylene terephthalate (r-PET) and chitosan. This is a hydrophilic and biodegradable polymer manufactured by deacetylation of chitin. The membrane was fabricated through an electrospinning method using environmentally-friendly materials. The flux ranged between 512–991 L/m2·h. Results showed that the membrane removed over 95% of heavy and light crude oils from wastewater. In this study, the use of biodegradable polymers such as chitosan is beneficial due to their non-toxic feature, availability, and inexpensiveness.
Previous HF physical separation studies demonstrated that the modification of membranes using appropriate materials has a drastic effect on oily wastewater treatment, significantly improving permeate flux, oil rejection, and facilitating membrane cleaning. The summary of HF physical separation studies for the treatment of oily wastewater is shown in Table 5.

5.2. Integration of Physical Separation and Biological Method

In MBRs, the bioreactor acts as a biological treatment processor and the membrane is used as a filter in the filtration process [26]. MBR studies for the treatment of oily wastewater are summarized in Table 6.
In the oil and gas industry, Razavi and Miri [139] used a bench-scale HF-MBR to treat real petroleum refinery wastewater under various HRT, flux, temperature, and different operational conditions. This system was operated at a COD concentration of 580 mg/L and TSS of 110 mg/L. MLSS ranged from 3 to 6.6 g/L with the addition of hydrocarbon in the wastewater and had HRTs ranging between 25–36 h. In the middle of the process, COD and BOD5 removal increased significantly due to good biomass growth conditions in the system. Reducing HRT during this experiment led to decreasing BOD5 and COD removals and excess biomass production that led to high membrane fouling and decreased flux. At high HRT, 36 h, the results indicated that the removal efficiency of COD and BOD5 were 82% and 89%, respectively.
Capodici et al. [207] developed a bench-scale HF-MBR unit to treat synthetic wastewater containing diesel fuel. The membrane flux was maintained at almost 15 L/m2·h and HRT was equal to 27 h. A reduction in suspended biomass occurred until day 54 due to exerting stress on the biomass by hydrocarbons and reducing metabolic activity that was not completely acclimated to the substrate. This hindered the production of EPS in the system. Sodium acetate was added to the feed solution which increased the suspended biomass up to 7 g TSS/L and provided an appropriate acclimation level and increased EPS leading to an increase in membrane fouling. However, during the last period, membrane fouling decreased due to unstable oil layer formation on the surface of the membrane which was significantly removed by high crossflow fluid. Removal efficiencies of TPH and total COD were achieved by over 85%.
To evaluate the performance of HF-MBR in saline conditions, Di Bella et al. [208] used a bench-scale HF-MBR system to treat shipboard slops and investigated the effect of salinity and organic loading rates on the system performance in two phases (i.e., phase 1: the acclimation of biomass to salinity was studied, phase 2: the acclimation of biomass to real slops was investigated). Results showed a good biomass acclimation to a gradual salinity (increased up to 15 g NaCl/L) offered the potential development of halotolerant bacteria. The oil removal efficiency was about 50%. In this study, in the first phase, microorganisms were exposed to salinity, and this increased SMP production due to the release of organic cellular constituents through secretion and cell autolysis which led to an increase in membrane fouling. In the second phase, the EPS concentrations decreased slightly, and, therefore, membrane fouling did not increase due to an inhibitory impact caused by the hydrocarbons on the suspended biomass activity. This study showed that a gradual increase of salinity and hydrocarbon is necessary to improve biomass acclimation if bacteria are not halophilic.
In another study, Cosenza et al. [209] reported the treatment of synthetic shipboard slops with two separate bench-scale MBR setups, one with and one without a saline environment. TPH and COD concentrations of the oily wastewater were 20 and 500 mg/L, respectively, at the beginning of the study. In the MBR experiment with a saline environment, the heterotrophic biomass was negatively influenced due to salt shock. During the operation, after day 27, membrane fouling increased which was a result of the stress exerted by the salinity on the biomass that was not acclimated to a substrate which resulted in the release of high SMP concentration. In the MBR experiment without a saline environment, biomass had higher performance efficiency. The ammonium removal efficiency was 70% for both systems, and COD removal efficiencies for MBR experiments with salinity and without salinity were 81% and 87%, respectively. This study shows the importance of acclimating the biomass to high salinity, otherwise, it hinders their ability to degrade contaminants in the wastewater. Another option would be to use halophilic/halotolerant bacteria to obtain high biodegradation performance.
Table 6. Summary of HF-MBR studies for the treatment of oily wastewater.
Table 6. Summary of HF-MBR studies for the treatment of oily wastewater.
ScaleMembrane MaterialMLSS (g/L)Pre-TreatmentMembrane Pore Size (µm)Membrane Surface Area (m2)Flow Rate (L/h)Flux (L/m2·h)Air Flow Rate (L/min)HRT (h)SRT (d)Operation TimeSalinity (g/L)Removal Efficiency (%)Wastewater TypeReference
BenchPVDF, manufactured by Zenon Environmental Systems Inc.7.6Electrocoagulation0.0350.047-1230--12 d-Oil: 95Hypersaline oilfield produced water[210]
BenchUF, manufactured by ZeeWeed4De-oiling,
coagulation, flocculation
0.040.090.815-27-215 dConductivity: 1.6 mS/cmOil: 85Synthetic oily wastewater (shipboard slop)[207]
BenchUF, manufactured by
ZeeWeed
4Chemical-physical pre-treatment0.040.093-15-27-90 d0Oil: 95Synthetic shipboard slops[209]
Bench16 wt% new polyvinylchloride (PVC) and 84 wt% Dimethylacetamide (DMAC) solvent1Gravity separation and DAF0.120.00113-----5 d-Oil: 100Oil refinery wastewater[211]
BenchSelf-made membrane, polypropylene3–6.6-0.150.390.471.2057036---COD: 82Real petroleum refinery[139]
BenchPolyetherimide, MF-Coalescer bed0.40.5-----8 h-Oil: 93–100Oil produced water[212]
BenchPVDF, UF, manufactured by ZeeWeed--0.04-0.5----210 d-COD: 91.8Oil refinery wastewater[213]
BenchMF, manufactured by Zena Membranes3.8-0.10.18-107-Infinite121 d8.7 ± 1.7Oil: 85Produced
water
[160]
PilotCoated with LiCl and TiO2, PVDF, UF4.5-0.0340.0184-82.950.00224.61---COD: 90.8Refinery wastewater[214]
BenchPolysulfone, manufactured by PolymemPolymer9PAC addition0.20.1-2-2420-0.09COD: 96Effluent from the oil industry[215]
BenchPolyetherimide, manufactured by PEI, Ultem 1000, GE-Sand filter0.15 ± 0.092.78 × 10−22.515.82-10-33 d-COD: 67Oil refinery wastewater[216]
BenchPVDF14–28-0.060.020-60.110Infinite71 d-Oil: 98Industrial oil contaminated wastewater[217]
PilotPVDF, MF, manufactured by Zenon-Oil/water separator, floatation system, sand filter0.0470-----6 months0.56COD: 84Refinery wastewater[218]
PilotPVC/Alloy manufactured by Litree Co.-Aeration tank, air flotation, sand filter0.00640-------Oil: 99Oilfield wastewater[219]
BenchSelf-made membrane, polypropylene, sealing procedure with a proper resin, symmetric MF8.2-0.40.2-0.42-31.8-11.25 d-COD and hydrocarbon: >90Industrial wastewater containing hydrocarbons[220]
PilotUnmodified-Gravity oil separation--20.8215--11--Ballast water COD: 38, Bilgewater COD: 56Oily wastewater including ballast and bilge water[221]
BenchMF, manufactured by Mitsubishi Rayon Co., Ltd.9.84PAC Addition0.10.42-3.57-45058 d-Oil: 99.9Oily wastewater from gas station[222]

6. Discussion and Recommendations

The development of HF membrane technology is promising for oily wastewater treatment. Previous studies have indicated that the key challenge in achieving an outstanding membrane performance to treat oily wastewater is to tackle membrane flux reduction and permeability as a result of fouling. Although a lot of studies have been focused on this subject, there may be opportunities for further improvement such as identifying optimal operating parameters to achieve sustainable flux in membrane filtration systems when treating oily wastewater.
Previous research papers discussed the effect of changing HF packing density, fiber length, fiber looseness, and fiber diameter on HF membrane performance. Low HF packing density, long and loose fibers, and small HF diameter allow lateral movement of fibers, which enhances the HF membrane filtration performance.
Inducing shear stress, unsteady-state condition on the membrane surface, and HF fiber oscillation through aeration mitigates membrane fouling and improves the membrane performance. Although aeration is a proven technique for reducing membrane fouling, there is a need for more research on ideal aeration conditions such as optimal bubble diameter, to improve membrane performance, and aeration frequency to reduce the energy demand of the system [13,23]. Bubble diameter affects shear stress on the membrane surface, and, so, finding the optimal bubble diameter will help maintain effective foulant removal and the homogeneity of the mixed liquor, which benefits the biodegradation process in MBR. Until now, there have not been any conclusive studies on the best bubble diameter to improve membrane system performance, therefore, further research on this topic can greatly improve the efficacy of membrane technology.
Previous HF physical separation studies focused on membrane modification to improve membrane performance. Most polymers which have been used in HF membrane production are hydrophobic, and, consequently, they repel water, promoting the passage of oil through the membrane. Oleophilic features allow for membrane pore blockage, the accumulation of an oily cake layer on the membrane surface, and, consequently, a reduction of membrane permeation performance, and decreasing membrane lifespan. Surface modification has proven to be exceptionally effective at preventing oil droplets from breaching the pores of the membrane and maintaining a high flux of water [116,124]. It was observed that membranes modified either by coating or surface grafting had better oil removal efficiencies than membranes that were not modified [3,116]. However, these studies are restricted to bench-scale laboratory experiments, and the challenge remains in preparing modified membranes for commercial use [13,223]. Developing more effective methods to implement membrane surface medication on a large scale would broaden the application of HF membrane technology, particularly in oily wastewater treatment. For example, the expansion of HF membrane application to onsite oil spill treatment or its use as a stand-alone system to treat complicated industrial emulsified oily wastewater. Additionally, recent studies have indicated the potential of using green technology in constructing highly efficient HF membranes [205,206]. During membrane surface modification, sustainable and cost-effective methods through environmentally-friendly materials should be considered [224].
In MBR applications, membrane fouling is still a major challenge similar to physical separation studies which impedes the achievement of excellent membrane performance for the treatment of oily wastewater [225,226]. Factors that affect membrane fouling are operating parameters such as HRT, SRT, and aeration that impact sludge characteristics [116]. A low F/M ratio is required for microbial maintenance, high F/M ratio causes the dispersion of bacteria and results in more EPS and SMP production leading to membrane fouling. Long SRT with high sludge age leads to a better performance of the MBR unit as it allows for biomass acclimation to the wastewater [146]. Longer HRTs improve effluent quality as it gives time for the biomass to degrade unwanted compounds in the water. Aeration flow rate is a vital parameter to monitor the treatment of wastewater since it provides dissolved oxygen to bacteria so that they may perform biodegradation [181]. Low aeration leads to anaerobic conditions in the bioreactor, resulting in the death of aerobic bacteria. A high aeration flow rate contributes to low sludge filterability by breaking floc formations. Both conditions will result in high EPS and SMP in the system which contributes to the clogging or blocking of the membrane.
High salt concentration and the existence of hydrocarbons in feed water cause environmental stress on the bacteria which can lead to inhibitory or toxic effects if they are not acclimated to this environment [227,228]. The environmental stress causes the bacteria to go through plasmolysis and/or loss of cell activity, or to produce excess SMP and EPS which lead to membrane fouling, by blocking membrane pores [228,229]. Acclimation of bacteria to the harsh environment will reduce EPS and SMP formation, consequently lowering the blockage of the membrane [208]. Additionally, selecting a suitable type of bacteria would improve biodegradation efficiency in the MBR system when treating oily wastewater. Halotolerant microorganisms isolated from saline environments such as saltwater, sea mud, and a saline lake inoculated in MBR systems would eliminate the need for long acclimation periods to saline conditions in the bioreactor.

7. Conclusions

The discharge of oily wastewater leads to serious environmental problems if released without sufficient treatment due to the recalcitrant nature, toxicity, and carcinogenicity of the hydrocarbon compounds. The generation of the high volume of oily wastewater is an alarming threat to the ecosystem, and, therefore, numerous oily wastewater treatment approaches have been studied to achieve an eco-friendly method that will enhance treatment efficiency. In this regard, a comprehensive review has been conducted to provide a perspective regarding the practical aspects of HF membrane technology for oily wastewater treatment. Reviewing HF membrane filtration studies for the treatment of oily wastewater demonstrated that optimizing operational parameters and membrane modifications can significantly improve HF membrane performance in terms of maintaining membrane flux and reducing fouling. High SRT with high sludge age is desirable for oily wastewater treatment since it allows for biomass acclimation. Moderate aeration is also required for ideal membrane performance. Modified HF membranes with good hydration capability facilitate the passage of water and lead to high permeability, resulting in reduced membrane fouling.

Author Contributions

L.L.: Methodology, Validation, Funding Acquisition, Resources, Writing—Review, and Editing. M.K.H.: Conceptualization, Methodology, Investigation, Analysis, Visualization, Writing—Original Draft, Review and Editing. P.K.H.: Conceptualization, Methodology, Investigation, Analysis, Visualization, Writing—Original Draft, Review and Editing. A.B.: Writing—Review and Editing. J.M.: Review and Editing. K.L.: Discussion, Review. B.C.: Discussion, Review. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Department of Fisheries and Oceans Canada (DFO), the Multi-Partner Research Initiative program (MPRI 4.01&4.03), and the Natural Sciences and Engineering Research Council (NSERC) RGPIN-2016-05801.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors would like to thank the Department of Fisheries and Oceans Canada (DFO) and Multi-Partner Research Initiative (MPRI) program as well as NSERC for the support during the research.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bolto, B.; Zhang, J.; Wu, X.; Xie, Z. A Review on Current Development of Membranes for Oil Removal from Wastewaters. Membranes 2020, 10, 65. [Google Scholar] [CrossRef] [PubMed]
  2. Bagheri, M.; Mirbagheri, S.A. Critical Review of Fouling Mitigation Strategies in Membrane Bioreactors Treating Water and Wastewater. Bioresour. Technol. 2018, 258, 318–334. [Google Scholar] [CrossRef] [PubMed]
  3. Ahmad, T.; Guria, C.; Mandal, A. A Review of Oily Wastewater Treatment Using Ultrafiltration Membrane: A Parametric Study to Enhance the Membrane Performance. J. Water Process Eng. 2020, 36, 101289. [Google Scholar] [CrossRef]
  4. Kuyukina, M.S.; Krivoruchko, A.V.; Ivshina, I.B. Advanced Bioreactor Treatments of Hydrocarbon-Containing Wastewater. Appl. Sci. 2020, 10, 831. [Google Scholar] [CrossRef]
  5. Adetunji, A.I.; Olaniran, A.O. Treatment of Industrial Oily Wastewater by Advanced Technologies: A Review. Appl. Water Sci. 2021, 11, 98. [Google Scholar] [CrossRef]
  6. Padaki, M.; Surya Murali, R.; Abdullah, M.S.; Misdan, N.; Moslehyani, A.; Kassim, M.A.; Hilal, N.; Ismail, A.F. Membrane Technology Enhancement in Oil–Water Separation. A Review. Desalination 2015, 357, 197–207. [Google Scholar] [CrossRef]
  7. Dalaklis, D.; Christodoulou, A.; Kitada, M. Oil Spill Response Training in the South Baltic Sea Region. In Proceedings of the INTED2020 Conference, Valencia, Spain, 2–4 March 2020; pp. 3309–3314. [Google Scholar]
  8. Mohammadi, L.; Rahdar, A.; Bazrafshan, E.; Dahmardeh, H.; Susan, M.A.B.H.; Kyzas, G.Z. Petroleum Hydrocarbon Removal from Wastewaters: A Review. Processes 2020, 8, 447. [Google Scholar] [CrossRef]
  9. Sanghamitra, P.; Mazumder, D.; Mukherjee, S. Treatment of Wastewater Containing Oil and Grease by Biological Method—A Review. J. Environ. Sci. Health Part A 2021, 56, 394–412. [Google Scholar] [CrossRef]
  10. Abuhasel, K.; Kchaou, M.; Alquraish, M.; Munusamy, Y.; Jeng, Y.T. Oily Wastewater Treatment: Overview of Conventional and Modern Methods, Challenges, and Future Opportunities. Water 2021, 13, 980. [Google Scholar] [CrossRef]
  11. Han, M.; Zhang, J.; Chu, W.; Chen, J.; Zhou, G. Research Progress and Prospects of Marine Oily Wastewater Treatment: A Review. Water 2019, 11, 2517. [Google Scholar] [CrossRef] [Green Version]
  12. Primasari, B.; Ibrahim, S.; Annuar, M.S.M.; Remmie, L.X.I. Aerobic Treatment of Oily Wastewater: Effect of Aeration and Sludge Concentration to Pollutant Reduction and PHB Accumulation. World Acad. Sci. Eng. Technol. 2011, 78, 172–176. [Google Scholar]
  13. Hube, S.; Eskafi, M.; Hrafnkelsdóttir, K.F.; Bjarnadóttir, B.; Bjarnadóttir, M.Á.; Axelsdóttir, S.; Wu, B. Direct Membrane Filtration for Wastewater Treatment and Resource Recovery: A Review. Sci. Total Environ. 2020, 710, 136375. [Google Scholar] [CrossRef] [PubMed]
  14. Nascimbén Santos, É.; László, Z.; Hodúr, C.; Arthanareeswaran, G.; Veréb, G. Photocatalytic Membrane Filtration and Its Advantages over Conventional Approaches in the Treatment of Oily Wastewater: A Review. Asia-Pac. J. Chem. Eng. 2020, 15, e2533. [Google Scholar] [CrossRef]
  15. Ge, J.; Zong, D.; Jin, Q.; Yu, J.; Ding, B. Biomimetic and Superwettable Nanofibrous Skins for Highly Efficient Separation of Oil-in-Water Emulsions. Adv. Funct. Mater. 2018, 28, 1705051. [Google Scholar] [CrossRef]
  16. Tanudjaja, H.J.; Hejase, C.A.; Tarabara, V.V.; Fane, A.G.; Chew, J.W. Membrane-Based Separation for Oily Wastewater: A Practical Perspective. Water Res. 2019, 156, 347–365. [Google Scholar] [CrossRef]
  17. Huang, S.; Pooi, C.K.; Shi, X.; Varjani, S.; Ng, H.Y. Performance and Process Simulation of Membrane Bioreactor (MBR) Treating Petrochemical Wastewater. Sci. Total Environ. 2020, 747, 141311. [Google Scholar] [CrossRef]
  18. Chang, I.-S.; Le Clech, P.; Jefferson, B.; Judd, S. Membrane Fouling in Membrane Bioreactors for Wastewater Treatment. J. Environ. Eng. 2002, 128, 1018–1029. [Google Scholar] [CrossRef]
  19. Manda, B.M.K.; Worrell, E.; Patel, M.K. Innovative Membrane Filtration System for Micropollutant Removal from Drinking Water–Prospective Environmental LCA and Its Integration in Business Decisions. J. Clean. Prod. 2014, 72, 153–166. [Google Scholar] [CrossRef]
  20. Wiesner, M.R.; Hackney, J.; Sethi, S.; Jacangelo, J.G.; Laîé, J.-M. Cost Estimates for Membrane Filtration and Conventional Treatment. J. Am. Water Work. Assoc. 1994, 86, 33–41. [Google Scholar] [CrossRef]
  21. Ioannou-Ttofa, L.; Michael-Kordatou, I.; Fattas, S.C.; Eusebio, A.; Ribeiro, B.; Rusan, M.; Amer, A.R.B.; Zuraiqi, S.; Waismand, M.; Linder, C.; et al. Treatment Efficiency and Economic Feasibility of Biological Oxidation, Membrane Filtration and Separation Processes, and Advanced Oxidation for the Purification and Valorization of Olive Mill Wastewater. Water Res. 2017, 114, 1–13. [Google Scholar] [CrossRef]
  22. Wang, W.K. Membrane Separations in Biotechnology; CRC Press: Boca Raton, FL, USA, 2001; ISBN 978-1-4822-8988-6. [Google Scholar]
  23. Akhondi, E.; Zamani, F.; Tng, K.; Leslie, G.; Krantz, W.; Fane, A.; Chew, J. The Performance and Fouling Control of Submerged Hollow Fiber (HF) Systems: A Review. Appl. Sci. 2017, 7, 765. [Google Scholar] [CrossRef]
  24. Wan, C.F.; Yang, T.; Lipscomb, G.G.; Stookey, D.J.; Chung, T.-S. Design and Fabrication of Hollow Fiber Membrane Modules. J. Membr. Sci. 2017, 538, 96–107. [Google Scholar] [CrossRef]
  25. Le-Clech, P.; Chen, V.; Fane, T.A.G. Fouling in Membrane Bioreactors Used in Wastewater Treatment. J. Membr. Sci. 2006, 284, 17–53. [Google Scholar] [CrossRef]
  26. Mutamim, N.S.A.; Noor, Z.Z.; Hassan, M.A.A.; Olsson, G. Application of Membrane Bioreactor Technology in Treating High Strength Industrial Wastewater: A Performance Review. Desalination 2012, 305, 1–11. [Google Scholar] [CrossRef]
  27. Izadi, A.; Hosseini, M.; Najafpour Darzi, G.; Nabi Bidhendi, G.; Pajoum Shariati, F.; Mosaddeghi, M.R. Perspectives on Membrane Bioreactor Potential for Treatment of Pulp and Paper Industry Wastewater: A Critical Review. J. Appl. Biotechnol. Rep. 2018, 5, 139–150. [Google Scholar] [CrossRef]
  28. Huang, S.; Ras, R.H.A.; Tian, X. Antifouling Membranes for Oily Wastewater Treatment: Interplay between Wetting and Membrane Fouling. Curr. Opin. Colloid Interface Sci. 2018, 36, 90–109. [Google Scholar] [CrossRef]
  29. Pendashteh, A.R.; Fakhru’l-Razi, A.; Madaeni, S.S.; Abdullah, L.C.; Abidin, Z.Z.; Biak, D.R.A. Membrane Foulants Characterization in a Membrane Bioreactor (MBR) Treating Hypersaline Oily Wastewater. Chem. Eng. J. 2011, 168, 140–150. [Google Scholar] [CrossRef]
  30. Ullah, A.; Tanudjaja, H.J.; Ouda, M.; Hasan, S.W.; Chew, J.W. Membrane Fouling Mitigation Techniques for Oily Wastewater: A Short Review. J. Water Process Eng. 2021, 43, 102293. [Google Scholar] [CrossRef]
  31. Kalla, S. Use of Membrane Distillation for Oily Wastewater Treatment—A Review. J. Environ. Chem. Eng. 2021, 9, 104641. [Google Scholar] [CrossRef]
  32. Ahmad, T.; Belwal, T.; Li, L.; Ramola, S.; Aadil, R.M.; Abdullah; Xu, Y.; Zisheng, L. Utilization of Wastewater from Edible Oil Industry, Turning Waste into Valuable Products: A Review. Trends Food Sci. Technol. 2020, 99, 21–33. [Google Scholar] [CrossRef]
  33. Iskandar, M.J.; Baharum, A.; Anuar, F.H.; Othaman, R. Palm Oil Industry in South East Asia and the Effluent Treatment Technology—A Review. Environ. Technol. Innov. 2018, 9, 169–185. [Google Scholar] [CrossRef]
  34. Ahmed, Y.; Yaakob, Z.; Akhtar, P.; Sopian, K. Production of Biogas and Performance Evaluation of Existing Treatment Processes in Palm Oil Mill Effluent (POME). Renew. Sustain. Energy Rev. 2015, 42, 1260–1278. [Google Scholar] [CrossRef]
  35. Cheryan, M.; Rajagopalan, N. Membrane Processing of Oily Streams. Wastewater Treatment and Waste Reduction. J. Membr. Sci. 1998, 151, 13–28. [Google Scholar] [CrossRef]
  36. MacAdam, J.; Ozgencil, H.; Autin, O.; Pidou, M.; Temple, C.; Parsons, S.; Jefferson, B. Incorporating Biodegradation and Advanced Oxidation Processes in the Treatment of Spent Metalworking Fluids. Environ. Technol. 2012, 33, 2741–2750. [Google Scholar] [CrossRef] [PubMed]
  37. Benito, J.; Ríos, G.; Ortea, E.; Fernández, E.; Cambiella, A.; Pazos, C.; Coca, J. Design and Construction of a Modular Pilot Plant for the Treatment of Oil-Containing Wastewaters. Desalination 2002, 147, 5–10. [Google Scholar] [CrossRef]
  38. Wu, P.; Jiang, L.Y.; He, Z.; Song, Y. Treatment of Metallurgical Industry Wastewater for Organic Contaminant Removal in China: Status, Challenges, and Perspectives. Environ. Sci. Water Res. Technol. 2017, 3, 1015–1031. [Google Scholar] [CrossRef]
  39. Eldos, H.I.; Khan, M.; Zouari, N.; Saeed, S.; Al-Ghouti, M.A. Characterization and Assessment of Process Water from Oil and Gas Production: A Case Study of Process Wastewater in Qatar. Case Stud. Chem. Environ. Eng. 2022, 6, 100210. [Google Scholar] [CrossRef]
  40. Munirasu, S.; Haija, M.A.; Banat, F. Use of Membrane Technology for Oil Field and Refinery Produced Water Treatment—A Review. Process Saf. Environ. Prot. 2016, 100, 183–202. [Google Scholar] [CrossRef]
  41. Fakhru’l-Razi, A.; Pendashteh, A.; Abdullah, L.C.; Biak, D.R.A.; Madaeni, S.S.; Abidin, Z.Z. Review of Technologies for Oil and Gas Produced Water Treatment. J. Hazard. Mater. 2009, 170, 530–551. [Google Scholar] [CrossRef]
  42. Bakke, T.; Klungsøyr, J.; Sanni, S. Environmental Impacts of Produced Water and Drilling Waste Discharges from the Norwegian Offshore Petroleum Industry. Mar. Environ. Res. 2013, 92, 154–169. [Google Scholar] [CrossRef]
  43. ITOPF Oil Tanker Spill Statistics. 2021. Available online: https://www.itopf.org/knowledge-resources/data-statistics/statistics/ (accessed on 27 June 2022).
  44. Martini, S.; Ang, H.M.; Znad, H. Integrated Ultrafiltration Membrane Unit for Efficient Petroleum Refinery Effluent Treatment: Water. CLEAN-Soil Air Water 2017, 45, 1600342. [Google Scholar] [CrossRef]
  45. Varjani, S.; Joshi, R.; Srivastava, V.K.; Ngo, H.H.; Guo, W. Treatment of Wastewater from Petroleum Industry: Current Practices and Perspectives. Environ. Sci. Pollut. Res. 2020, 27, 27172–27180. [Google Scholar] [CrossRef] [PubMed]
  46. Coca, J.; Gutiérrez, G.; Benito, J. Treatment of Oily Wastewater. In Water Purification and Management; Coca-Prados, J., Gutiérrez-Cervelló, G., Eds.; NATO Science for Peace and Security Series C: Environmental Security; Springer: Dordrecht, The Netherlands, 2011; pp. 1–55. ISBN 978-90-481-9774-3. [Google Scholar]
  47. Aliff Radzuan, M.R.; Abia-Biteo Belope, M.A.; Thorpe, R.B. Removal of Fine Oil Droplets from Oil-in-Water Mixtures by Dissolved Air Flotation. Chem. Eng. Res. Des. 2016, 115, 19–33. [Google Scholar] [CrossRef]
  48. Sun, Y.; Zhu, C.; Zheng, H.; Sun, W.; Xu, Y.; Xiao, X.; You, Z.; Liu, C. Characterization and Coagulation Behavior of Polymeric Aluminum Ferric Silicate for High-Concentration Oily Wastewater Treatment. Chem. Eng. Res. Des. 2017, 119, 23–32. [Google Scholar] [CrossRef]
  49. Ghidossi, R.; Veyret, D.; Scotto, J.L.; Jalabert, T.; Moulin, P. Ferry Oily Wastewater Treatment. Sep. Purif. Technol. 2009, 64, 296–303. [Google Scholar] [CrossRef]
  50. MicÃ, M.M.; Arnaldos, M.; Medina, F.; Contreras, S. State of the Art of Produced Water Treatment. Chemosphere 2018, 192, 186–208. [Google Scholar]
  51. De Medeiros, A.D.M.; da Silva Junior, C.J.G.; de Amorim, J.D.P.; Durval, I.J.B.; de Costa, A.F.S.; Sarubbo, L.A. Oily Wastewater Treatment: Methods, Challenges, and Trends. Processes 2022, 10, 743. [Google Scholar] [CrossRef]
  52. Sylvester, N.D.; Byeseda, J.J. Oil/Water Separation by Induced-Air Flotation. Soc. Pet. Eng. J. 1980, 20, 579–590. [Google Scholar] [CrossRef]
  53. Hanafy, M.; Nabih, H.I. Treatment of Oily Wastewater Using Dissolved Air Flotation Technique. Energy Sources Part Recovery Util. Environ. Eff. 2007, 29, 143–159. [Google Scholar] [CrossRef]
  54. Stephenson, R.L.; Blackburn, J.B. The Industrial Wastewater Systems Handbook; CRC Press: Boca Raton, FL, USA, 2018. [Google Scholar]
  55. Mohamad Radzi, A.R. Removal of Oil Droplets from Oil-in-Water Mixtures by Dissolved Air Flotation (DAF). Ph.D. Thesis, University of Surrey, Guildford, UK, 2017. [Google Scholar]
  56. Igwe, I.O. The Effects of Temperature on the Viscosity of Vegetable Oils in Solution. Ind. Crops Prod. 2004, 19, 185–190. [Google Scholar] [CrossRef]
  57. Santander, M.; Rodrigues, R.T.; Rubio, J. Modified Jet Flotation in Oil (Petroleum) Emulsion/Water Separations. Colloids Surf. Physicochem. Eng. Asp. 2011, 375, 237–244. [Google Scholar] [CrossRef]
  58. Li, M.; Deng, L.; Tan, Y.; Qi, K.; Tian, X.; Yu, J.; Qin, C.; Cheng, S. Superhydrophobic/Superoleophilic Polyacrylonitrile/Ag Aerogels for the High Efficient Oil/Water Separation and Sensitive Detection of Low-Concentration Oily Sudan Dyes. Adv. Mater. Interfaces 2021, 8, 2002174. [Google Scholar] [CrossRef]
  59. Yu, L.; Han, M.; He, F. A Review of Treating Oily Wastewater. Arab. J. Chem. 2017, 10, S1913–S1922. [Google Scholar] [CrossRef]
  60. Li, Z.Y.; Xie, S.; Jiang, G.; Bao, M.; Wang, Z.; Huang, X.; Xu, F. Bioremediation of Offshore Oily Drilling Fluids. Energy Sources Part Recovery Util. Environ. Eff. 2015, 37, 1680–1687. [Google Scholar] [CrossRef]
  61. Zeng, E. Persistent Organic Pollutants (POPs): Analytical Techniques, Environmental Fate and Biological Effects; Elsevier: Amsterdam, The Netherlands, 2015; ISBN 978-0-444-63300-2. [Google Scholar]
  62. Zhai, J.; Huang, Z.; Rahaman, M.H.; Li, Y.; Mei, L.; Ma, H.; Hu, X.; Xiao, H.; Luo, Z.; Wang, K. Comparison of Coagulation Pretreatment of Produced Water from Natural Gas Well by Polyaluminium Chloride and Polyferric Sulphate Coagulants. Environ. Technol. 2017, 38, 1200–1210. [Google Scholar] [CrossRef] [PubMed]
  63. Li, L.-J.; Qi, P.-S.; Liu, Y.-Z.; Qi, Z.; Zhao, J.-J. Poly Ferric Silicate Sulphate (PFSiS): Characterization, Coagulation Behavior and Applications in Oily Wastewater Treatment. In Proceedings of the 2009 3rd International Conference on Bioinformatics and Biomedical Engineering, Beijing, China, 11–13 June 2009; pp. 1–4. [Google Scholar]
  64. Ahmad, A.L.; Sumathi, S.; Hameed, B.H. Coagulation of Residue Oil and Suspended Solid in Palm Oil Mill Effluent by Chitosan, Alum and PAC. Chem. Eng. J. 2006, 118, 99–105. [Google Scholar] [CrossRef]
  65. Tansel, B.; Pascual, B. Factorial Evaluation of Operational Variables of a DAF Process to Improve PHC Removal Efficiency. Desalination 2004, 169, 1–10. [Google Scholar] [CrossRef]
  66. Moosai, R.; Dawe, R.A. Gas Attachment of Oil Droplets for Gas Flotation for Oily Wastewater Cleanup. Sep. Purif. Technol. 2003, 33, 303–314. [Google Scholar] [CrossRef]
  67. Zeng, Y.; Yang, C.; Zhang, J.; Pu, W. Feasibility Investigation of Oily Wastewater Treatment by Combination of Zinc and PAM in Coagulation/Flocculation. J. Hazard. Mater. 2007, 147, 991–996. [Google Scholar] [CrossRef]
  68. Sun, S.; Jia, L.; Li, B.; Yuan, A.; Kong, L.; Qi, H.; Ma, W.; Zhang, A.; Wu, Y. The Occurrence and Fate of PAHs over Multiple Years in a Wastewater Treatment Plant of Harbin, Northeast China. Sci. Total Environ. 2018, 624, 491–498. [Google Scholar] [CrossRef]
  69. Ahamed, M.I.; Lichtfouse, E. (Eds.) Water Pollution and Remediation: Organic Pollutants; Springer International Publishing: Cham, Switzerland, 2021; Volume 54, ISBN 978-3-030-52394-7. [Google Scholar]
  70. Goh, P.S.; Ong, C.S.; Ng, B.C.; Ismail, A.F. 5-Applications of Emerging Nanomaterials for Oily Wastewater Treatment. In Nanotechnology in Water and Wastewater Treatment; Micro and Nano Technologies; Ahsan, A., Ismail, A.F., Eds.; Elsevier: Amsterdam, The Netherlands, 2019; pp. 101–113. ISBN 978-0-12-813902-8. [Google Scholar]
  71. Sharghi, E.A.; Shourgashti, A.; Bonakdarpour, B. Considering a Membrane Bioreactor for the Treatment of Vegetable Oil Refinery Wastewaters at Industrially Relevant Organic Loading Rates. Bioprocess Biosyst. Eng. 2020, 43, 981–995. [Google Scholar] [CrossRef] [PubMed]
  72. Singh, V.; Purkait, M.K.; Das, C. Cross-Flow Microfiltration of Industrial Oily Wastewater: Experimental and Theoretical Consideration. Sep. Sci. Technol. 2011, 46, 1213–1223. [Google Scholar] [CrossRef]
  73. Saththasivam, J.; Loganathan, K.; Sarp, S. An Overview of Oil–Water Separation Using Gas Flotation Systems. Chemosphere 2016, 144, 671–680. [Google Scholar] [CrossRef] [PubMed]
  74. Nieuwenhuis, E.; Post, J.; Duinmeijer, A.; Langeveld, J.; Clemens, F. Statistical Modelling of Fat, Oil and Grease (FOG) Deposits in Wastewater Pump Sumps. Water Res. 2018, 135, 155–167. [Google Scholar] [CrossRef] [PubMed]
  75. Zhao, B.; Ren, L.; Du, Y.; Wang, J. Eco-Friendly Separation Layers Based on Waste Peanut Shell for Gravity-Driven Water-in-Oil Emulsion Separation. J. Clean. Prod. 2020, 255, 120184. [Google Scholar] [CrossRef]
  76. Kundu, P.; Mishra, I.M. Treatment and Reclamation of Hydrocarbon-Bearing Oily Wastewater as a Hazardous Pollutant by Different Processes and Technologies: A State-of-the-Art Review. Rev. Chem. Eng. 2018, 35, 73–108. [Google Scholar] [CrossRef]
  77. SaiNan, G.; JunRu, W.; XiangFeng, H.; Wei, G.; LiJun, L.; Jia, L. Experimental study on activated carbon adsorption for treating effluents from oil-field wastewater treatment facilities. Environ. Sci. Technol. China 2010, 33, 56–65. [Google Scholar]
  78. Ulucan, K.; Kurt, U. Comparative Study of Electrochemical Wastewater Treatment Processes for Bilge Water as Oily Wastewater: A Kinetic Approach. J. Electroanal. Chem. 2015, 747, 104–111. [Google Scholar] [CrossRef]
  79. Mohadesi, M.; Shokri, A. Treatment of Oil Refinery Wastewater by Photo-Fenton Process Using Box–Behnken Design Method: Kinetic Study and Energy Consumption. Int. J. Environ. Sci. Technol. 2019, 16, 7349–7356. [Google Scholar] [CrossRef]
  80. AlJaberi, F.Y.; Ahmed, S.A.; Makki, H.F. Electrocoagulation Treatment of High Saline Oily Wastewater: Evaluation and Optimization. Heliyon 2020, 6, e03988. [Google Scholar] [CrossRef]
  81. Liu, B.; Chen, B.; Zhang, B.; Song, X.; Zeng, G.; Lee, K. Photocatalytic Ozonation of Offshore Produced Water by TiO2 Nanotube Arrays Coupled with UV-LED Irradiation. J. Hazard. Mater. 2021, 402, 123456. [Google Scholar] [CrossRef] [PubMed]
  82. Liu, B.; Chen, B.; Ling, J.; Matchinski, E.J.; Dong, G.; Ye, X.; Wu, F.; Shen, W.; Liu, L.; Lee, K.; et al. Development of Advanced Oil/Water Separation Technologies to Enhance the Effectiveness of Mechanical Oil Recovery Operations at Sea: Potential and Challenges. J. Hazard. Mater. 2022, 437, 129340. [Google Scholar] [CrossRef] [PubMed]
  83. Zhang, Z. The Flocculation Mechanism and Treatment of Oily Wastewater by Flocculation. Water Sci. Technol. 2017, 76, 2630–2637. [Google Scholar] [CrossRef] [Green Version]
  84. Mota, A.L.N.; Albuquerque, L.F.; Beltrame, L.T.C.; Chiavone-Filho, O.; Machulek, A., Jr.; Nascimento, C.A.O. Advanced oxidation processes and their application in the petroleum industry: A review. Braz. J. Pet. Gas 2009, 2, 122–142. [Google Scholar]
  85. Elmobarak, W.F.; Hameed, B.H.; Almomani, F.; Abdullah, A.Z. A Review on the Treatment of Petroleum Refinery Wastewater Using Advanced Oxidation Processes. Catalysts 2021, 11, 782. [Google Scholar] [CrossRef]
  86. Shanker, U.; Jassal, V.; Rani, M. Degradation of Toxic PAHs in Water and Soil Using Potassium Zinc Hexacyanoferrate Nanocubes. J. Environ. Manag. 2017, 204, 337–348. [Google Scholar] [CrossRef] [PubMed]
  87. Ma, D.; Yi, H.; Lai, C.; Liu, X.; Huo, X.; An, Z.; Li, L.; Fu, Y.; Li, B.; Zhang, M.; et al. Critical Review of Advanced Oxidation Processes in Organic Wastewater Treatment. Chemosphere 2021, 275, 130104. [Google Scholar] [CrossRef]
  88. Gotsi, M.; Kalogerakis, N.; Psillakis, E.; Samaras, P.; Mantzavinos, D. Electrochemical Oxidation of Olive Oil Mill Wastewaters. Water Res. 2005, 39, 4177–4187. [Google Scholar] [CrossRef]
  89. Galvão, S.A.O.; Mota, A.L.N.; Silva, D.N.; Moraes, J.E.F.; Nascimento, C.A.O.; Chiavone-Filho, O. Application of the Photo-Fenton Process to the Treatment of Wastewaters Contaminated with Diesel. Sci. Total Environ. 2006, 367, 42–49. [Google Scholar] [CrossRef]
  90. Chong, M.N.; Jin, B.; Chow, C.W.K.; Saint, C. Recent Developments in Photocatalytic Water Treatment Technology: A Review. Water Res. 2010, 44, 2997–3027. [Google Scholar] [CrossRef]
  91. Sivagami, K.; Anand, D.; Divyapriya, G.; Nambi, I. Treatment of Petroleum Oil Spill Sludge Using the Combined Ultrasound and Fenton Oxidation Process. Ultrason. Sonochem. 2019, 51, 340–349. [Google Scholar] [CrossRef] [PubMed]
  92. Lafi, W.K.; Shannak, B.; Al-Shannag, M.; Al-Anber, Z.; Al-Hasan, M. Treatment of Olive Mill Wastewater by Combined Advanced Oxidation and Biodegradation. Sep. Purif. Technol. 2009, 70, 141–146. [Google Scholar] [CrossRef]
  93. Guyer, J.P. An Introduction to Oily Wastewater Collection and Treatment; Continuing Education and Development, Inc.: Stony Point, NY, USA, 2013; p. 97. [Google Scholar]
  94. Okiel, K.; El-Sayed, M.; El-Kady, M.Y. Treatment of Oil–Water Emulsions by Adsorption onto Activated Carbon, Bentonite and Deposited Carbon. Egypt. J. Pet. 2011, 20, 9–15. [Google Scholar] [CrossRef]
  95. Islam, S. Investigation of Oil Adsorption Capacity of Granular Organoclay Media and the Kinetics of Oil Removal from Oil-in-Water Emulsions; Texas A&M University: College Station, TX, USA, 2007. [Google Scholar]
  96. Zhou, Y.-B.; Tang, X.-Y.; Hu, X.-M.; Fritschi, S.; Lu, J. Emulsified Oily Wastewater Treatment Using a Hybrid-Modified Resin and Activated Carbon System. Sep. Purif. Technol. 2008, 63, 400–406. [Google Scholar] [CrossRef]
  97. Hao, L.; Jiang, B.; Zhang, L.; Yang, H.; Sun, Y.; Wang, B.; Yang, N. Efficient Demulsification of Diesel-in-Water Emulsions by Different Structural Dendrimer-Based Demulsifiers. Ind. Eng. Chem. Res. 2016, 55, 1748–1759. [Google Scholar] [CrossRef]
  98. Sousa, A.M.; Pereira, M.J.; Matos, H.A. Oil-in-Water and Water-in-Oil Emulsions Formation and Demulsification. J. Pet. Sci. Eng. 2022, 210, 110041. [Google Scholar] [CrossRef]
  99. Ali, A.; Salman, W.; Dwesh, H. Using Amides Demulsifiers for Crude Oil Processing. Egypt. J. Chem. 2022, 65, 551–558. [Google Scholar] [CrossRef]
  100. Wu, J.; Xu, Y.; Dabros, T.; Hamza, H. Effect of Demulsifier Properties on Destabilization of Water-in-Oil Emulsion. Energy Fuels 2003, 17, 1554–1559. [Google Scholar] [CrossRef]
  101. Panda, S.K.; Mohammed, M.A.; Cadix, A.; Alaboalirat, M.; Poix-Davaine, C.; Duran, E. Size Exclusion Chromatography Reveals a Key Parameter of Demulsifiers for Enhanced Water Separation from Crude Oil Emulsions. Fuel 2019, 257, 115881. [Google Scholar] [CrossRef]
  102. Razi, M.; Rahimpour, M.R.; Jahanmiri, A.; Azad, F. Effect of a Different Formulation of Demulsifiers on the Efficiency of Chemical Demulsification of Heavy Crude Oil. J. Chem. Eng. Data 2011, 56, 2936–2945. [Google Scholar] [CrossRef]
  103. Hasan, S.W.; Ghannam, M.T.; Esmail, N. Heavy Crude Oil Viscosity Reduction and Rheology for Pipeline Transportation. Fuel 2010, 89, 1095–1100. [Google Scholar] [CrossRef]
  104. Elmawgoud, H.A.; Elshiekh, T.M.; Khalil, S.A.; Alsabagh, A.M.; Tawfik, M. Modeling of Hydrogen Sulfide Removal from Petroleum Production Facilities Using H2S Scavenger. Egypt. J. Pet. 2015, 24, 131–137. [Google Scholar] [CrossRef]
  105. Li, Z.; Geng, H.; Wang, X.; Jing, B.; Liu, Y.; Tan, Y. Noval Tannic Acid-Based Polyether as an Effective Demulsifier for Water-in-Aging Crude Oil Emulsions. Chem. Eng. J. 2018, 354, 1110–1119. [Google Scholar] [CrossRef]
  106. Rossi, A.F. Fenton’s Process Applied to Wastewaters Treatment: Heterogenous and Homogenous Catalytic Operations Mode. Ph.D. Thesis, University of Coimbra, Coimbra, Portugal, 2014; p. 187. [Google Scholar]
  107. Xu, M.; Wu, C.; Zhou, Y. Advancements in the Fenton Process for Wastewater Treatment. In Advanced Oxidation Processes: Applications, Trends, and Prospects; Intechopen: London, UK, 2020. [Google Scholar]
  108. Schramm, L.L. Surfactants: Fundamentals and Applications in the Petroleum Industry; Cambridge University Press: Cambridge, UK, 2000. [Google Scholar]
  109. Chanthamalee, J.; Wongchitphimon, T.; Luepromchai, E. Treatment of Oily Bilge Water from Small Fishing Vessels by PUF-Immobilized Gordonia Sp. JC11. Water. Air. Soil Pollut. 2013, 224, 1601. [Google Scholar] [CrossRef]
  110. Santo, C.E.; Vilar, V.J.P.; Bhatnagar, A.; Kumar, E.; Botelho, C.M.S.; Boaventura, R.A.R. Biological Treatment by Activated Sludge of Petroleum Refinery Wastewaters. Desalination Water Treat. 2013, 51, 6641–6654. [Google Scholar] [CrossRef]
  111. Shokrollahzadeh, S.; Azizmohseni, F.; Golmohammad, F.; Shokouhi, H.; Khademhaghighat, F. Biodegradation Potential and Bacterial Diversity of a Petrochemical Wastewater Treatment Plant in Iran. Bioresour. Technol. 2008, 99, 6127–6133. [Google Scholar] [CrossRef] [PubMed]
  112. Otadi, N.; Hassani, A.H.; Javid, A.H.; Khiabani, F.F. Oily Compounds Removal in Wastewater Treatment System of Pars Oil Refinery to Improve Its Efficiency in a Lab Scale Pilot. J. Water Chem. Technol. 2010, 32, 370–377. [Google Scholar] [CrossRef]
  113. Sun, C.; Leiknes, T.; Weitzenböck, J.; Thorstensen, B. Development of a Biofilm-MBR for Shipboard Wastewater Treatment: The Effect of Process Configuration. Desalination 2010, 250, 745–750. [Google Scholar] [CrossRef]
  114. Mafirad, S.; Mehrnia, M.R.; Sarrafzadeh, M.H. Effect of Membrane Characteristics on the Performance of Membrane Bioreactors for Oily Wastewater Treatment. Water Sci. Technol. 2011, 64, 1154–1160. [Google Scholar] [CrossRef]
  115. Kang, Y.; Xia, Y.; Wang, H.; Zhang, X. 2D Laminar Membranes for Selective Water and Ion Transport. Adv. Funct. Mater. 2019, 29, 1902014. [Google Scholar] [CrossRef]
  116. Ismail, N.H.; Salleh, W.N.W.; Ismail, A.F.; Hasbullah, H.; Yusof, N.; Aziz, F.; Jaafar, J. Hydrophilic Polymer-Based Membrane for Oily Wastewater Treatment: A Review. Sep. Purif. Technol. 2020, 233, 116007. [Google Scholar] [CrossRef]
  117. Chanunpanich, N.; Hongsik, B.; Inn-Kyu, K. Membrane Morphology: Phase Inversion to Electrospinning. Membr. J. 2005, 15, 85–104. [Google Scholar]
  118. Tang, Y.; Lin, Y.; Ford, D.M.; Qian, X.; Cervellere, M.R.; Millett, P.C.; Wang, X. A Review on Models and Simulations of Membrane Formation via Phase Inversion Processes. J. Membr. Sci. 2021, 640, 119810. [Google Scholar] [CrossRef]
  119. Ahmed, F.E.; Lalia, B.S.; Hashaikeh, R. A Review on Electrospinning for Membrane Fabrication: Challenges and Applications. Desalination 2015, 356, 15–30. [Google Scholar] [CrossRef]
  120. Barani, M.; Bazgir, S.; Keyvan Hosseini, M.; Keyvan Hosseini, P. Eco-Facile Application of Electrospun Nanofibers to the Oil-Water Emulsion Separation via Coalescing Filtration in Pilot- Scale and Beyond. Process Saf. Environ. Prot. 2021, 148, 342–357. [Google Scholar] [CrossRef]
  121. Montanheiro, T.L.d.A.; Schatkoski, V.M.; de Menezes, B.R.C.; Pereira, R.M.; Ribas, R.G.; De Sousa, A.; Lemes, A.P.; Fernandes, M.H.F.V.; Thim, G.P. Recent Progress on Polymer Scaffolds Production: Methods, Main Results, Advantages and Disadvantages. Express Polym. Lett. 2022, 16, 197–219. [Google Scholar] [CrossRef]
  122. Shi, X.; Zhou, W.; Ma, D.; Ma, Q.; Bridges, D.; Ma, Y.; Hu, A. Electrospinning of Nanofibers and Their Applications for Energy Devices. J. Nanomater. 2015, 2015, 140716. [Google Scholar] [CrossRef]
  123. Baig, N.; Salhi, B.; Sajid, M.; Aljundi, I.H. Recent Progress in Microfiltration/Ultrafiltration Membranes for Separation of Oil and Water Emulsions. Chem. Rec. 2021, 22, e202100320. [Google Scholar] [CrossRef]
  124. Zulkefli, N.F.; Alias, N.H.; Jamaluddin, N.S.; Abdullah, N.; Abdul Manaf, S.F.; Othman, N.H.; Marpani, F.; Mat-Shayuti, M.S.; Kusworo, T.D. Recent Mitigation Strategies on Membrane Fouling for Oily Wastewater Treatment. Membranes 2021, 12, 26. [Google Scholar] [CrossRef]
  125. Cheng, B.; Li, Z.; Li, Q.; Ju, J.; Kang, W.; Naebe, M. Development of Smart Poly(Vinylidene Fluoride)-Graft-Poly(Acrylic Acid) Tree-like Nanofiber Membrane for PH-Responsive Oil/Water Separation. J. Membr. Sci. 2017, 534, 1–8. [Google Scholar] [CrossRef]
  126. Wang, Z.; Lin, S. The Impact of Low-Surface-Energy Functional Groups on Oil Fouling Resistance in Membrane Distillation. J. Membr. Sci. 2017, 527, 68–77. [Google Scholar] [CrossRef]
  127. Chen, P.C.; Xu, Z.-K. Mineral-Coated Polymer Membranes with Superhydrophilicity and Underwater Superoleophobicity for Effective Oil/Water Separation. Sci. Rep. 2013, 3, 2776. [Google Scholar] [CrossRef] [PubMed]
  128. Kumar, S.; Mandal, A.; Guria, C. Synthesis, Characterization and Performance Studies of Polysulfone and Polysulfone/Polymer-Grafted Bentonite Based Ultrafiltration Membranes for the Efficient Separation of Oil Field Oily Wastewater. Process Saf. Environ. Prot. 2016, 102, 214–228. [Google Scholar] [CrossRef]
  129. Venault, A.; Wei, T.-C.; Shih, H.-L.; Yeh, C.-C.; Chinnathambi, A.; Alharbi, S.A.; Carretier, S.; Aimar, P.; Lai, J.-Y.; Chang, Y. Antifouling Pseudo-Zwitterionic Poly(Vinylidene Fluoride) Membranes with Efficient Mixed-Charge Surface Grafting via Glow Dielectric Barrier Discharge Plasma-Induced Copolymerization. J. Membr. Sci. 2016, 516, 13–25. [Google Scholar] [CrossRef]
  130. Zhou, Y.; Yu, S.; Gao, C.; Feng, X. Surface Modification of Thin Film Composite Polyamide Membranes by Electrostatic Self Deposition of Polycations for Improved Fouling Resistance. Sep. Purif. Technol. 2009, 66, 287–294. [Google Scholar] [CrossRef]
  131. Yang, M.; Hadi, P.; Yin, X.; Yu, J.; Huang, X.; Ma, H.; Walker, H.; Hsiao, B.S. Antifouling Nanocellulose Membranes: How Subtle Adjustment of Surface Charge Lead to Self-Cleaning Property. J. Membr. Sci. 2021, 618, 118739. [Google Scholar] [CrossRef]
  132. De Jong, J.; Lammertink, R.G.H.; Wessling, M. Membranes and Microfluidics: A Review. Lab. Chip 2006, 6, 1125. [Google Scholar] [CrossRef]
  133. Alzahrani, S.; Mohammad, A.W. Challenges and Trends in Membrane Technology Implementation for Produced Water Treatment: A Review. J. Water Process Eng. 2014, 4, 107–133. [Google Scholar] [CrossRef]
  134. Rezakazemi, M.; Khajeh, A.; Mesbah, M. Membrane Filtration of Wastewater from Gas and Oil Production. Environ. Chem. Lett. 2018, 16, 367–388. [Google Scholar] [CrossRef]
  135. Hu, J.; Ma, Y.; Zhang, L.; Gan, F.; Ho, Y.-S. A Historical Review and Bibliometric Analysis of Research on Lead in Drinking Water Field from 1991 to 2007. Sci. Total Environ. 2010, 408, 1738–1744. [Google Scholar] [CrossRef]
  136. Pabby, A.K.; Rizvi, S.S.H.; Requena, A.M.S. (Eds.) Handbook of Membrane Separations: Chemical, Pharmaceutical, Food, and Biotechnological Applications; CRC Press: Boca Raton, FL, USA, 2008; ISBN 978-0-429-12806-6. [Google Scholar]
  137. Malaeb, L.; Ayoub, G.M. Reverse Osmosis Technology for Water Treatment: State of the Art Review. Desalination 2011, 267, 1–8. [Google Scholar] [CrossRef]
  138. Berk, Z. Food Process Engineering and Technology; Academic Press: Cambridge, MA, USA, 2018; ISBN 978-0-12-812054-5. [Google Scholar]
  139. Razavi, S.M.R.; Miri, T. A Real Petroleum Refinery Wastewater Treatment Using Hollow Fiber Membrane Bioreactor (HF-MBR). J. Water Process Eng. 2015, 8, 136–141. [Google Scholar] [CrossRef]
  140. Masoudnia, K.; Raisi, A.; Aroujalian, A.; Fathizadeh, M. A Hybrid Microfiltration/Ultrafiltration Membrane Process for Treatment of Oily Wastewater. Desalination Water Treat. 2014, 55, 901–912. [Google Scholar] [CrossRef]
  141. Le-Clech, P.; Jefferson, B.; Judd, S.J. A Comparison of Submerged and Sidestream Tubular Membrane Bioreactor Configurations. Desalination 2005, 173, 113–122. [Google Scholar] [CrossRef]
  142. Obotey Ezugbe, E.; Rathilal, S. Membrane Technologies in Wastewater Treatment: A Review. Membranes 2020, 10, 89. [Google Scholar] [CrossRef]
  143. Judd, S. Fouling Control in Submerged Membrane Bioreactors. Water Sci. Technol. J. Int. Assoc. Water Pollut. Res. 2005, 51, 27–34. [Google Scholar] [CrossRef]
  144. Al-Khafaji, S.S.; Al-Rekabi, W.S.; Mawat, M.J. Apply Membrane Biological Reactor (MBR) in Industrial Wastewater Treatment: A Mini Review. Eurasian J. Eng. Technol. 2022, 7, 98–106. [Google Scholar]
  145. Kharraz, J.A.; Khanzada, N.K.; Farid, M.U.; Kim, J.; Jeong, S.; An, A.K. Membrane Distillation Bioreactor (MDBR) for Wastewater Treatment, Water Reuse, and Resource Recovery: A Review. J. Water Process Eng. 2022, 47, 102687. [Google Scholar] [CrossRef]
  146. Park, H.-D.; Chang, I.-S.; Lee, K.-J. Principles of Membrane Bioreactors for Wastewater Treatment; CRC Press: Boca Raton, FL, USA, 2015; ISBN 978-1-4665-9038-0. [Google Scholar]
  147. Frederickson, K.C. The Application of a Membrane Bioreactor for Wastewater Treatment on a Northern Manitoban Aboriginal Community; University of Manitoba: Winnipeg, MB, Canada, 2005; p. 126. [Google Scholar]
  148. Doyen, W.; Mues, W.; Molenberghs, B.; Cobben, B. Spacer Fabric Supported Flat-Sheet Membranes: A New Era of Flat-Sheet Membrane Technology. Desalination 2010, 250, 1078–1082. [Google Scholar] [CrossRef]
  149. Baker, R.W. Membrane Technology and Applications; John Wiley & Sons: Hoboken, NJ, USA, 2012. [Google Scholar]
  150. Wolff, C.; Beutel, S.; Scheper, T. Tubular Membrane Bioreactors for Biotechnological Processes. Appl. Microbiol. Biotechnol. 2013, 97, 929–937. [Google Scholar] [CrossRef]
  151. Dickson, J.M.; Spencer, J.; Costa, M.L. Dilute Single and Mixed Solute Systems in a Spiral Wound Reserve Osmosis Module Part I: Theoretical Model Development. Desalination 1992, 89, 63–88. [Google Scholar] [CrossRef]
  152. Synderfiltration Membrane Filters: Spiral-Wound Ultrafiltration Eléments. Available online: https://synderfiltration.com/ultrafiltration/spiral-wound/ (accessed on 30 July 2022).
  153. Judd, S. The MBR Book: Principles and Applications of Membrane Bioreactors for Water and Wastewater Treatment. Elsevier: Amsterdam, The Netherlands, 2010. [Google Scholar]
  154. Huang, X.; Wang, W.; Liu, Y.; Wang, H.; Zhang, Z.; Fan, W.; Li, L. Treatment of Oily Waste Water by PVP Grafted PVDF Ultrafiltration Membranes. Chem. Eng. J. 2015, 273, 421–429. [Google Scholar] [CrossRef]
  155. Kim, B.R.; Kalis, E.M.; Florkey, D.L.; Swatsenbarg, S.L.; Luciw, L.; Bailey, C.H.; Gaines, W.A.; Phillips, J.H.; Kosokowsky, G.B. Evaluation of Commercial Ultrafiltration Systems for Treating Automotive Oily Wastewater. Water Environ. Res. 1998, 70, 1280–1289. [Google Scholar] [CrossRef]
  156. Li, Y.S.; Yan, L.; Xiang, C.B.; Hong, L.J. Treatment of Oily Wastewater by Organic–Inorganic Composite Tubular Ultrafiltration (UF) Membranes. Desalination 2006, 196, 76–83. [Google Scholar] [CrossRef]
  157. Schwinge, J.; Neal, P.R.; Wiley, D.E.; Fletcher, D.F.; Fane, A.G. Spiral Wound Modules and Spacers. J. Membr. Sci. 2004, 242, 129–153. [Google Scholar] [CrossRef]
  158. Radjenovic, J.; Matošić, M.; Mijatović, I.; Petrovic, M.; Barcelo, D. Membrane Bioreactor (MBR) as an Advanced Wastewater Treatment Technology. In Handbook of Environmental Chemistry; Springer: Berlin/Heidelberg, Germany, 2008; Volume 5, pp. 37–101. [Google Scholar] [CrossRef]
  159. Marchese, J.; Ochoa, N.A.; Pagliero, C.; Almandoz, C. Pilot-Scale Ultrafiltration of an Emulsified Oil Wastewater. Environ. Sci. Technol. 2000, 34, 2990–2996. [Google Scholar] [CrossRef]
  160. Kose, B.; Ozgun, H.; Ersahin, M.E.; Dizge, N.; Koseoglu-Imer, D.Y.; Atay, B.; Kaya, R.; Altınbas, M.; Sayılı, S.; Hoshan, P.; et al. Performance Evaluation of a Submerged Membrane Bioreactor for the Treatment of Brackish Oil and Natural Gas Field Produced Water. Desalination 2012, 285, 295–300. [Google Scholar] [CrossRef]
  161. Salahi, A.; Mohammadi, T.; Behbahani, R.M.; Hemmati, M. Experimental Investigation and Modeling of Industrial Oily Wastewater Treatment Using Modified Polyethersulfone Ultrafiltration Hollow Fiber Membranes. Korean J. Chem. Eng. 2015, 32, 1101–1118. [Google Scholar] [CrossRef]
  162. Ayub, M.; Othman, M.H.D.; Kadir, S.H.S.A.; Ali, A.; Khan, I.U.; Yusop, M.Z.M.; Matsuura, T.; Fauzi Ismail, A.; Rahman, M.A.; Jaafar, J. Research and Development Journey and Future Trends of Hollow Fiber Membranes for Purification Applications (1970–2020): A Bibliometric Analysis. Membranes 2021, 11, 600. [Google Scholar] [CrossRef]
  163. Zhu, X.; Tu, W.; Wee, K.-H.; Bai, R. Effective and Low Fouling Oil/Water Separation by a Novel Hollow Fiber Membrane with Both Hydrophilic and Oleophobic Surface Properties. J. Membr. Sci. 2014, 466, 36–44. [Google Scholar] [CrossRef]
  164. Johari, A.; Razmjouei, M.; Mansourizadeh, A.; Emadzadeh, D. Fabrication of Blend Hydrophilic Polyamide Imide (Torlon®)-Sulfonated Poly (Ether Ether Ketone) Hollow Fiber Membranes for Oily Wastewater Treatment. Polym. Test. 2020, 91, 106733. [Google Scholar] [CrossRef]
  165. Di Profio, G.; Ji, X.; Curcio, E.; Drioli, E. Submerged Hollow Fiber Ultrafiltration as Seawater Pretreatment in the Logic of Integrated Membrane Desalination Systems. Desalination 2011, 269, 128–135. [Google Scholar] [CrossRef]
  166. Chang, S. Application of Submerged Hollow Fiber Membrane in Membrane Bioreactors: Filtration Principles, Operation, and Membrane Fouling. Desalination 2011, 283, 31–39. [Google Scholar] [CrossRef]
  167. Yeo, A.; Fane, A.G. Performance of Individual Fibers in a Submerged Hollow Fiber Bundle. Water Sci. Technol. J. Int. Assoc. Water Pollut. Res. 2005, 51, 165–172. [Google Scholar] [CrossRef]
  168. Fulton, B.G.; Bérubé, P.R. Optimizing the Sparging Condition and Membrane Module Spacing for a ZW500 Submerged Hollow Fiber Membrane System. Desalination Water Treat. 2012, 42, 8–16. [Google Scholar] [CrossRef]
  169. Yang, X.; Fridjonsson, E.O.; Johns, M.L.; Wang, R.; Fane, A.G. A Non-Invasive Study of Flow Dynamics in Membrane Distillation Hollow Fiber Modules Using Low-Field Nuclear Magnetic Resonance Imaging (MRI). J. Membr. Sci. 2014, 451, 46–54. [Google Scholar] [CrossRef]
  170. Bérubé, P.R.; Lei, E. The Effect of Hydrodynamic Conditions and System Configurations on the Permeate Flux in a Submerged Hollow Fiber Membrane System. J. Membr. Sci. 2006, 271, 29–37. [Google Scholar] [CrossRef]
  171. Pourbozorg, M.; Li, T.; Law, A.W.-K. Fouling of Submerged Hollow Fiber Membrane Filtration in Turbulence: Statistical Dependence and Cost-Benefit Analysis. J. Membr. Sci. 2017, 521, 43–52. [Google Scholar] [CrossRef]
  172. Chang, S.; Fane, A.G. Filtration of Biomass with Laboratory-Scale Submerged Hollow Fibre Modules–Effect of Operating Conditions and Module Configuration. J. Chem. Technol. Biotechnol. 2002, 77, 1030–1038. [Google Scholar] [CrossRef]
  173. Li, T.; Law, A.W.-K.; Cetin, M.; Fane, A.G. Fouling Control of Submerged Hollow Fibre Membranes by Vibrations. J. Membr. Sci. 2013, 427, 230–239. [Google Scholar] [CrossRef]
  174. Wicaksana, F.; Fan, A.G.; Chen, V. The Relationship between Critical Flux and Fibre Movement Induced by Bubbling in a Submerged Hollow Fibre System. Water Sci. Technol. 2005, 51, 115–122. [Google Scholar] [CrossRef]
  175. Chang, S.; Fane, A.G. The Effect of Fibre Diameter on Filtration and Flux Distribution—Relevance to Submerged Hollow Fibre Modules. J. Membr. Sci. 2001, 184, 221–231. [Google Scholar] [CrossRef]
  176. Kim, J.; DiGiano, F.A. Fouling Models for Low-Pressure Membrane Systems. Sep. Purif. Technol. 2009, 68, 293–304. [Google Scholar] [CrossRef]
  177. Li, X.; Li, J.; Cui, Z.; Yao, Y. Modeling of Filtration Characteristics during Submerged Hollow Fiber Membrane Microfiltration of Yeast Suspension under Aeration Condition. J. Membr. Sci. 2016, 510, 455–465. [Google Scholar] [CrossRef]
  178. Khanafer, K.; Assad, M.E.H. Mathematical Modeling of Fluid Flow Through a Hollow Fiber Water System Using Porous Medium Model. Arab. J. Sci. Eng. 2022, 47, 6049–6057. [Google Scholar] [CrossRef]
  179. Liu, R.; Huang, X.; Wang, C.; Chen, L.; Qian, Y. Study on Hydraulic Characteristics in a Submerged Membrane Bioreactor Process. Process Biochem. 2000, 36, 249–254. [Google Scholar] [CrossRef]
  180. Pradhan, M.; Aryal, R.; Vigneswaran, S.; Kandasamy, J. Application of Air Flow for Mitigation of Particle Deposition in Submerged Membrane Microfiltration. Desalination Water Treat. 2011, 32, 201–207. [Google Scholar] [CrossRef]
  181. Wibisono, Y.; Cornelissen, E.R.; Kemperman, A.J.B.; van der Meer, W.G.J.; Nijmeijer, K. Two-Phase Flow in Membrane Processes: A Technology with a Future. J. Membr. Sci. 2014, 453, 566–602. [Google Scholar] [CrossRef]
  182. Du, X.; Qu, F.-S.; Liang, H.; Li, K.; Bai, L.-M.; Li, G.-B. Control of Submerged Hollow Fiber Membrane Fouling Caused by Fine Particles in Photocatalytic Membrane Reactors Using Bubbly Flow: Shear Stress and Particle Forces Analysis. Sep. Purif. Technol. 2017, 172, 130–139. [Google Scholar] [CrossRef]
  183. Cabassud, C.; Laborie, S.; Durand-Bourlier, L.; Lainé, J.M. Air Sparging in Ultrafiltration Hollow Fibers: Relationship between Flux Enhancement, Cake Characteristics and Hydrodynamic Parameters. J. Membr. Sci. 2001, 181, 57–69. [Google Scholar] [CrossRef]
  184. Ueda, T.; Hata, K.; Kikuoka, Y. Treatment of Domestic Sewage from Rural Settlements by a Membrane Bioreactor. Water Sci. Technol. 1996, 34, 189–196. [Google Scholar] [CrossRef]
  185. Bouhabila, E. Fouling Characterisation in Membrane Bioreactors. Sep. Purif. Technol. 2001, 51, 95–103. [Google Scholar] [CrossRef]
  186. Guibert, D.; Aim, R.B.; Rabie, H.; Côté, P. Aeration Performance of Immersed Hollow-Fiber Membranes in a Bentonite Suspension. Desalination 2002, 148, 395–400. [Google Scholar] [CrossRef]
  187. Lin, H.; Zhang, M.; Wang, F.; Meng, F.; Liao, B.-Q.; Hong, H.; Chen, J.; Gao, W. A Critical Review of Extracellular Polymeric Substances (EPSs) in Membrane Bioreactors: Characteristics, Roles in Membrane Fouling and Control Strategies. J. Membr. Sci. 2014, 460, 110–125. [Google Scholar] [CrossRef]
  188. Shi, Y.; Huang, J.; Zeng, G.; Gu, Y.; Hu, Y.; Tang, B.; Zhou, J.; Yang, Y.; Shi, L. Evaluation of Soluble Microbial Products (SMP) on Membrane Fouling in Membrane Bioreactors (MBRs) at the Fractional and Overall Level: A Review. Rev. Environ. Sci. Biotechnol. 2018, 17, 71–85. [Google Scholar] [CrossRef]
  189. Bhattacharyya, A.; Liu, L.; Lee, K.; Miao, J. Review of Biological Processes in a Membrane Bioreactor (MBR): Effects of Wastewater Characteristics and Operational Parameters on Biodegradation Efficiency When Treating Industrial Oily Wastewater. J. Mar. Sci. Eng. 2022, 10, 1229. [Google Scholar] [CrossRef]
  190. Iorhemen, O.T.; Hamza, R.A.; Tay, J.H. Membrane Bioreactor (MBR) Technology for Wastewater Treatment and Reclamation: Membrane Fouling. Membranes 2016, 6, 33. [Google Scholar] [CrossRef]
  191. Trussell, R.S.; Merlo, R.P.; Hermanowicz, S.W.; Jenkins, D. The Effect of Organic Loading on Process Performance and Membrane Fouling in a Submerged Membrane Bioreactor Treating Municipal Wastewater. Water Res. 2006, 40, 2675–2683. [Google Scholar] [CrossRef]
  192. Meng, F.; Yang, F. Fouling Mechanisms of Deflocculated Sludge, Normal Sludge, and Bulking Sludge in Membrane Bioreactor. J. Membr. Sci. 2007, 305, 48–56. [Google Scholar] [CrossRef]
  193. Dvořák, L.; Gómez, M.; Dvořáková, M.; Růžičková, I.; Wanner, J. The Impact of Different Operating Conditions on Membrane Fouling and EPS Production. Bioresour. Technol. 2011, 102, 6870–6875. [Google Scholar] [CrossRef]
  194. Lobos, J.; Wisniewski, C.; Heran, M.; Grasmick, A. Effects of Starvation Conditions on Biomass Behaviour for Minimization of Sludge Production in Membrane Bioreactors. Water Sci. Technol. 2005, 51, 35–44. [Google Scholar] [CrossRef]
  195. Robinson, T. Wastewater Treatment: Membrane Bioreactor Cleans up Distillery Wastewater. Filtr. Sep. 2009, 46, 40–41. [Google Scholar] [CrossRef]
  196. Luis, P. Fundamental Modeling of Membrane Systems: Membrane and Process Performance; Elsevier: Amsterdam, The Netherlands, 2018. [Google Scholar]
  197. Deng, L.; Guo, W.; Ngo, H.H.; Zhang, J.; Liang, S.; Xia, S.; Zhang, Z.; Li, J. A Comparison Study on Membrane Fouling in a Sponge-Submerged Membrane Bioreactor and a Conventional Membrane Bioreactor. Bioresour. Technol. 2014, 165, 69–74. [Google Scholar] [CrossRef] [PubMed]
  198. QianHong, S.; LiNa, C.; WeiLi, Z.; ZhenJia, Z. Overview of forward osmosis membrane separation technology: Research and its application to water treatment. Environ. Sci. Technol. China 2010, 33, 117–122. [Google Scholar]
  199. Meng, F.; Yang, F.; Shi, B.; Zhang, H. A Comprehensive Study on Membrane Fouling in Submerged Membrane Bioreactors Operated under Different Aeration Intensities. Sep. Purif. Technol. 2008, 59, 91–100. [Google Scholar] [CrossRef]
  200. Park, S.; Yeon, K.-M.; Moon, S.; Kim, J.-O. Enhancement of Operating Flux in a Membrane Bio-Reactor Coupled with a Mechanical Sieve Unit. Chemosphere 2018, 191, 573–579. [Google Scholar] [CrossRef]
  201. Luo, L.; Han, G.; Chung, T.-S.; Weber, M.; Staudt, C.; Maletzko, C. Oil/Water Separation via Ultrafiltration by Novel Triangle-Shape Tri-Bore Hollow Fiber Membranes from Sulfonated Polyphenylenesulfone. J. Membr. Sci. 2015, 476, 162–170. [Google Scholar] [CrossRef]
  202. Otitoju, T.A.; Ahmad, A.L.; Ooi, B.S. Polyethersulfone Composite Hollow-Fiber Membrane Prepared by in-Situ Growth of Silica with Highly Improved Oily Wastewater Separation Performance. J. Polym. Res. 2017, 24, 123. [Google Scholar] [CrossRef]
  203. Shen, C.; Zhang, Q.; Meng, Q. PSU-g-SBMA Hollow Fiber Membrane for Treatment of Oily Wastewater. Water Sci. Technol. 2021, 84, 3576–3585. [Google Scholar] [CrossRef]
  204. El-badawy, T.; Othman, M.H.D.; Adam, M.R.; Kamaludin, R.; Ismail, A.F.; Rahman, M.A.; Jaafar, J.; Rajabzadeh, S.; Matsuyama, H.; Usman, J.; et al. Braid-Reinforced PVDF Hollow Fiber Membranes for High-Efficiency Separation of Oily Wastewater. J. Environ. Chem. Eng. 2022, 10, 107258. [Google Scholar] [CrossRef]
  205. Baggio, A.; Doan, H.N.; Vo, P.P.; Kinashi, K.; Sakai, W.; Tsutsumi, N.; Fuse, Y.; Sangermano, M. Chitosan-Functionalized Recycled Polyethylene Terephthalate Nanofibrous Membrane for Sustainable On-Demand Oil-Water Separation. Glob. Chall. 2021, 5, 2000107. [Google Scholar] [CrossRef] [PubMed]
  206. Doan, H.N.; Phong Vo, P.; Hayashi, K.; Kinashi, K.; Sakai, W.; Tsutsumi, N. Recycled PET as a PDMS-Functionalized Electrospun Fibrous Membrane for Oil-Water Separation. J. Environ. Chem. Eng. 2020, 8, 103921. [Google Scholar] [CrossRef]
  207. Capodici, M.; Cosenza, A.; Di Trapani, D.; Mannina, G.; Torregrossa, M.; Viviani, G. Treatment of Oily Wastewater with Membrane Bioreactor Systems. Water 2017, 9, 412. [Google Scholar] [CrossRef]
  208. Di Bella, G.; Di Prima, N.; Di Trapani, D.; Freni, G.; Giustra, M.G.; Torregrossa, M.; Viviani, G. Performance of Membrane Bioreactor (MBR) Systems for the Treatment of Shipboard Slops: Assessment of Hydrocarbon Biodegradation and Biomass Activity under Salinity Variation. J. Hazard. Mater. 2015, 300, 765–778. [Google Scholar] [CrossRef] [PubMed]
  209. Cosenza, A.; Di Trapani, D.; Mannina, G.; Nicosia, S.; Torregrossa, M.; Viviani, G. Comparison between Two MBR Pilot Plants Treating Synthetic Shipboard Slops: Effect of Salinity Increase on Biological Performance, Biomass Activity and Fouling Tendency. Desalination Water Treat. 2017, 61, 240–249. [Google Scholar] [CrossRef]
  210. Al-Malack, M.H.; Al-Nowaiser, W.K. Treatment of Synthetic Hypersaline Produced Water Employing Electrocoagulation-Membrane Bioreactor (EC-MBR) Process and Halophilic Bacteria. J. Environ. Chem. Eng. 2018, 6, 2442–2453. [Google Scholar] [CrossRef]
  211. Alsalhy, Q.F.; Almukhtar, R.S.; Alani, H.A. Oil Refinery Wastewater Treatment by Using Membrane Bioreactor (MBR). Arab. J. Sci. Eng. 2016, 41, 2439–2452. [Google Scholar] [CrossRef]
  212. Motta, A.; Borges, C.; Esquerre, K.; Kiperstok, A. Oil Produced Water Treatment for Oil Removal by an Integration of Coalescer Bed and Microfiltration Membrane Processes. J. Membr. Sci. 2014, 469, 371–378. [Google Scholar] [CrossRef]
  213. Veronese, C.G.; Beal, L.L.; Santiago, V.M.J.; Torres, A.P.; Cerqueira, A.C. Ultrafiltration Hollow Fiber Membrane Bioreactor (Mbr) Treating Oil Refinery Wastewater. Procedia Eng. 2012, 44, 704–706. [Google Scholar] [CrossRef]
  214. Yuliwati, E.; Ismail, A.F.; Lau, W.J.; Ng, B.C.; Mataram, A.; Kassim, M.A. Effects of Process Conditions in Submerged Ultrafiltration for Refinery Wastewater Treatment: Optimization of Operating Process by Response Surface Methodology. Desalination 2012, 287, 350–361. [Google Scholar] [CrossRef]
  215. Lesage, N.; Sperandio, M.; Cabassud, C. Study of a Hybrid Process: Adsorption on Activated Carbon/Membrane Bioreactor for the Treatment of an Industrial Wastewater. Chem. Eng. Process. Process Intensif. 2008, 47, 303–307. [Google Scholar] [CrossRef]
  216. Viero, A.; Demelo, T.; Torres, A.; Ferreira, N.; Santannajr, G.; Borges, C.; Santiago, V. The Effects of Long-Term Feeding of High Organic Loading in a Submerged Membrane Bioreactor Treating Oil Refinery Wastewater. J. Membr. Sci. 2008, 319, 223–230. [Google Scholar] [CrossRef]
  217. Bienati, B.; Bottino, A.; Capannelli, G.; Comite, A. Characterization and Performance of Different Types of Hollow Fibre Membranes in a Laboratory-Scale MBR for the Treatment of Industrial Wastewater. Desalination 2008, 231, 133–140. [Google Scholar] [CrossRef]
  218. Torres, A.P.R.; Santiago, V.M.J.; Borges, C.P. Performance Evaluation of Submerged Membrane Bioreactor Pilot Units for Refinery Wastewater Treatment. Environ. Prog. 2008, 27, 189–194. [Google Scholar] [CrossRef]
  219. Qiao, X.; Zhang, Z.; Yu, J.; Ye, X. Performance Characteristics of a Hybrid Membrane Pilot-Scale Plant for Oilfield-Produced Wastewater. Desalination 2008, 225, 113–122. [Google Scholar] [CrossRef]
  220. Alberti, F.; Bienati, B.; Bottino, A.; Capannelli, G.; Comite, A.; Ferrari, F.; Firpo, R. Hydrocarbon Removal from Industrial Wastewater by Hollow-Fibre Membrane Bioreactors. Desalination 2007, 204, 24–32. [Google Scholar] [CrossRef]
  221. Galil, N.I.; Levinsky, Y. Sustainable Reclamation and Reuse of Industrial Wastewater Including Membrane Bioreactor Technologies: Case Studies. Desalination 2007, 202, 411–417. [Google Scholar] [CrossRef]
  222. Tri, P.T.; Visvanathan, C.; Jegatheesan, V. Biological Treatment of Oily Wastewater from Gas Stations by Membrane Bioreactor. J. Environ. Eng. Sci. 2006, 5, 309–316. [Google Scholar] [CrossRef]
  223. Naim, R.; Pei Sean, G.; Nasir, Z.; Mokhtar, N.M.; Safiah Muhammad, N.A. Recent Progress and Challenges in Hollow Fiber Membranes for Wastewater Treatment and Resource Recovery. Membranes 2021, 11, 839. [Google Scholar] [CrossRef]
  224. Lau, H.S.; Lau, S.K.; Soh, L.S.; Hong, S.U.; Gok, X.Y.; Yi, S.; Yong, W.F. State-of-the-Art Organic- and Inorganic-Based Hollow Fiber Membranes in Liquid and Gas Applications: Looking Back and Beyond. Membranes 2022, 12, 539. [Google Scholar] [CrossRef]
  225. Jepsen, K.; Bram, M.; Pedersen, S.; Yang, Z. Membrane Fouling for Produced Water Treatment: A Review Study From a Process Control Perspective. Water 2018, 10, 847. [Google Scholar] [CrossRef]
  226. Du, X.; Shi, Y.; Jegatheesan, V.; Haq, I.U. A Review on the Mechanism, Impacts and Control Methods of Membrane Fouling in MBR System. Membranes 2020, 10, 24. [Google Scholar] [CrossRef] [PubMed]
  227. Reid, E.; Liu, X.; Judd, S.J. Effect of High Salinity on Activated Sludge Characteristics and Membrane Permeability in an Immersed Membrane Bioreactor. J. Membr. Sci. 2006, 283, 164–171. [Google Scholar] [CrossRef]
  228. Capodici, M.; Cosenza, A.; Di Bella, G.; Di Trapani, D.; Viviani, G.; Mannina, G. High Salinity Wastewater Treatment by Membrane Bioreactors. In Current Developments in Biotechnology and Bioengineering; Elsevier: Amsterdam, The Netherlands, 2020; pp. 177–204. ISBN 978-0-12-819854-4. [Google Scholar]
  229. Luo, W.; Hai, F.I.; Kang, J.; Price, W.E.; Guo, W.; Ngo, H.H.; Yamamoto, K.; Nghiem, L.D. Effects of Salinity Build-up on Biomass Characteristics and Trace Organic Chemical Removal: Implications on the Development of High Retention Membrane Bioreactors. Bioresour. Technol. 2015, 177, 274–281. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Various fiber packing configurations of submerged HF membrane module “adapted from [166]”.
Figure 1. Various fiber packing configurations of submerged HF membrane module “adapted from [166]”.
Jmse 10 01313 g001
Table 1. Physical methods to treat oily wastewater.
Table 1. Physical methods to treat oily wastewater.
MethodProsConsTypes of Removed OilReference
Gravity SeparationLow cost,
simple device
Large footprint,
limited separation capacity and poor treatment effect on emulsified oil
Free oil[11]
Dissolved Air Flotation (DAF)High-quality effluent,
improved surface loading
High operating cost, large footprintDispersed oil,
emulsified oil
[73,74]
CoagulationLow cost,
small equipment,
easy to operate,
well-established and practical
Poor treatment effect with surfactant,
complicated composition, a large amount of coagulant, generation of sludge
Dispersed oil,
emulsified oil
[11,75]
Membrane SeparationHigh-quality permeate, small footprint, low energy input, low generation of wasteMembrane fouling requires cleaning and backwashing,
and incurred cost
Dispersed oil,
emulsified oil
[8,11,76]
Table 2. Chemical methods to treat oily wastewater.
Table 2. Chemical methods to treat oily wastewater.
MethodProsConsTypes of Removed OilReference
AdsorptionDepending on the type of adsorbents it has high selectivity,
high adsorption capacity,
high reuse rate
Material preparation is time-consuming and complex,
adsorbing water by organic adsorbents as much as oil adsorption
Emulsified oil[11]
Electrochemical OxidationLow space requirements,
efficient treatment in a short time,
effective removal of oil and grease
High cost,
high power consumption,
complex device
Emulsified oil,
hazardous metal ions
[11]
Photocatalytic
Process
Able to oxidize persistent combinations which are not oxidized during biological treatmentHigh energy consumption, low efficiencyEmulsified oil[59,81]
Fenton ProcessEffective in removing toxic wastewater,
short reaction time,
using easy-to-handle reagents
High cost of consuming reagents,
harsh acidic atmosphere,
high generation of ferric sludge
Emulsified oil[106,107]
DemulsificationEffective in accelerating the separation of oil and water process,
easily used with reasonable cost,
minimizing the amount of heat and settling time required
Expensive, toxic,
high consumption
Emulsified oil[108]
Table 3. Biological methods to treat oily wastewater.
Table 3. Biological methods to treat oily wastewater.
MethodProsConsTypes of Removed OilReference
Microbial
Metabolism
Low cost,
no additional chemical operation, high removal of BOD and SS
Time-consuming,
low efficiency,
difficult to handle on a large scale, microbial mechanism complexity
Emulsified oil[11,76]
BiofilmLow cost, simple operation,
high separation efficiency
Formation of diffusion resistance to the substrate and nutrient as a result of increasing cell layer,
immobilization process takes several times at the beginning of the experiment, limited operation time
Emulsified oil[11,76]
Table 4. Comparison of different membrane configurations.
Table 4. Comparison of different membrane configurations.
ConfigurationApplicationsAdvantagesDisadvantagesOil Removal Efficiency (%)Reference
Plate and Frame Membrane
Module
UF and RO,
MBR,
Food and beverage,
Oily Wastewater
Easily removing solids from water,
easy to clean,
moderate potential for fouling
Low packing,
high cost,
not back flushable,
the lowest membrane area per unit volume,
low efficiency compared to other configurations,
high-pressure drop
Hybrid MF/UF: 99.9%
UF: >95%
[138,140,142,147,153,154]
Tubular
Membrane
Module
MF/UF,
wastewater with high dissolved and suspended solids, oil, and grease
Less fouling compared to plate and frame,
handling the highest solids load,
easy to clean
Low packing density,
not back flushable,
very high cost,
very large footprint
UF: 99%
UF: 98.04%
[142,147,153,155,156]
Spiral-Wound Membrane
Module
RO/NF/MF
UF,
whey protein concentration,
lactose concentration,
cathodic/anodic paint recovery,
dye desalting,
sulfate removal,
oil separation
Easy cleaning through cleaning in place, small footprint,
robust design,
low capital and operating cost
Lower packing density than HF,
high potential for fouling, not back flushable
UF: 90.1%
UF: 99.7%
[35,142,153,157,158,159]
HF Membrane ModuleMF/UF and RO,
MBR,
industrial wastewater, oily wastewater
juice processing, biotech applications
Moderate capital cost,
very high packing density, back flushable,
capable to generate movement by mechanisms such as bubbling,
higher membrane area per unit volume compared to flat-sheet membranes
Fiber breakage,
high operating cost,
high potential of fouling
UF: 99%
UF: 98.5%
[142,147,153,158,160,161]
Table 5. Summary of physical separation studies using modified HF membranes for oily wastewater treatment.
Table 5. Summary of physical separation studies using modified HF membranes for oily wastewater treatment.
Membrane MaterialAdditive PolymerMembrane Pore Size (µm)Membrane Surface Area (m2)Flux (L/m2ˑh)Removal Efficiency (%)Wastewater TypeReference
PVDFPET0.075–0.401-620above 99.5%.Crude Oil[204]
PETChitosan--512–991>95Kerosene, hexane, carbon tetrachloride (CTC), and tetrachlo roethylene (TCE)[205]
Polysulfone (PSU)Sulfobetaine methacrylate (SBMA)--267>98.5Soybean oil, olive oil, lard oil, gasoline, diesel oil, and crude oil[203]
Polyethylene
terephthalate (rPET)
Polydimethylsiloxane (PDMS)--20,000>98%Oil[206]
Polyamide imide (PAI)Sulfonated poly (ether ether keton) (SPEEK)0.012, 0.03, 0.081-32>95Petroleum Refinery[164]
PESTetraethyloxysilane (TEOS), polyethylene glycol, silicon sol, and 1-methyl-2-pyrrolidone (NMP)0.1020.00890.93799.98Crude Oil[202]
PolyphenylenesulfoneSulfonated polyphenylenesulfone (SPPSU)0.0109–0.0186--TOC: > 95.4Oil-in-water Emulsion[201]
PVDFP(VDF-co-CTFE)-g-PMAA-g-fPEG0.097–0.1410.008510–7298, 99, 70Hexadecane, Crude Oil, Palm Oil[163]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Keyvan Hosseini, M.; Liu, L.; Keyvan Hosseini, P.; Bhattacharyya, A.; Lee, K.; Miao, J.; Chen, B. Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges. J. Mar. Sci. Eng. 2022, 10, 1313. https://doi.org/10.3390/jmse10091313

AMA Style

Keyvan Hosseini M, Liu L, Keyvan Hosseini P, Bhattacharyya A, Lee K, Miao J, Chen B. Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges. Journal of Marine Science and Engineering. 2022; 10(9):1313. https://doi.org/10.3390/jmse10091313

Chicago/Turabian Style

Keyvan Hosseini, Mahsa, Lei Liu, Parisa Keyvan Hosseini, Anisha Bhattacharyya, Kenneth Lee, Jiahe Miao, and Bing Chen. 2022. "Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges" Journal of Marine Science and Engineering 10, no. 9: 1313. https://doi.org/10.3390/jmse10091313

APA Style

Keyvan Hosseini, M., Liu, L., Keyvan Hosseini, P., Bhattacharyya, A., Lee, K., Miao, J., & Chen, B. (2022). Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges. Journal of Marine Science and Engineering, 10(9), 1313. https://doi.org/10.3390/jmse10091313

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop