Can Type of Instrumentation and Activation of the Final Irrigant Improve the Obturation Quality in Oval Root Canals? A Push-Out Bond Strength Study
Abstract
:Simple Summary
Abstract
1. Introduction
2. Materials and Methods
2.1. Specimen Preparation
2.2. Stages of the Study
2.3. Root Canal Instrumentation
2.4. Final Irrigation Activation
2.5. Measurement of Dislocation Resistance by Push-Out Bond Strength Test
2.6. Data Presentation and Analysis
3. Results
3.1. Effect of Instrumentation Protocol
3.2. Effect of Final Irrigant Activation Protocol
3.3. Effect of Root Filling Material
3.4. Mode of Failure
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Martins, J.; Silva, E.; Marques, D.; Belladonna, F.; Simões-Carvalho, M.; Vieira, V.; Antunes, H.; Fernandes, F.; Versiani, M. Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments. Int. Endod. J. 2021, 54, 1623–1637. [Google Scholar] [CrossRef] [PubMed]
- Metzger, Z. The self—A djusting file (SAF) system: An evidence-based update. J. Conserv. Dent. 2014, 17, 401–419. [Google Scholar] [CrossRef] [Green Version]
- Paqué, F.; Al-Jadaa, A.; Kfir, A. Hard-tissue debris accumulation created by conventional rotary versus self-adjusting file instrumentation in mesial root canal systems of mandibular molars. Int. Endod. J. 2012, 45, 413–418. [Google Scholar] [CrossRef] [PubMed]
- De-Deus, G.; Souza, E.M.; Barino, B.; Maia, J.; Zamolyi, R.Q.; Reis, C.; Kfir, A. The self-adjusting file optimizes debridement quality in oval-shaped root canals. J. Endod. 2011, 37, 701–705. [Google Scholar] [CrossRef] [PubMed]
- Muhammad, O.H.; Chevalier, M.; Rocca, J.P.; Brulat-Bouchard, N.; Medioni, E. Photodynamic therapy versus ultrasonic irrigation: Interaction with endodontic microbial biofilm, an ex vivo study. Photodiag. Photodyn. Ther. 2014, 11, 171–181. [Google Scholar] [CrossRef] [PubMed]
- Pawar, A.M.; Pawar, S.; Kfir, A.; Pawar, M.; Kokate, S. Push-out bond strength of root fillings made with C-Point and BC sealer versus gutta-percha and AH Plus after the instrumentation of oval canals with the self-adjusting file versus WaveOne. Int. Endod. J. 2016, 49, 374–381. [Google Scholar] [CrossRef]
- Nagas, E.; Kucukkaya, S.; Eymirli, A.; Uyanik, M.; Cehreli, Z. Effect of laser-activated irrigation on the push-out bond strength of ProRoot mineral Trioxide aggregate and biodentine in furcal perforations. Photomed. Laser Surg. 2017, 35, 231–235. [Google Scholar] [CrossRef] [PubMed]
- Nunes, V.; Silva, R.; Alfredo, E.; Sousa-Neto, M.; Silva-Sousa, Y. Adhesion of Epiphany and AH plus sealers to human root dentin treated with different solutions. Braz. Dent. J. 2008, 19, 46–50. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Quintão, C.; Costa, S.; Lacerda, M.; Girelli, C.; De Lima, C. Adhesion capacity of bioceramic and resin-based root canal sealer to root dentin: An integrative review. Rev. Bras. Odontol. 2020, 77, 1. [Google Scholar] [CrossRef]
- Akyuz Ekim, S.; Erdemir, A. Effect of different irrigant activation protocols on push-out bond strength. Lasers Med. Sci. 2015, 30, 2143–2149. [Google Scholar] [CrossRef] [PubMed]
- De-Deus, G.; Barino, B.; Marins, J.; Magalhães, K.; Thuanne, K.; Kfir, A. Self-adjusting file cleaning-shaping-irrigation system optimizes the filling of oval-shaped canals with thermoplasticized gutta-percha. J. Endod. 2012, 38, 846–849. [Google Scholar] [CrossRef] [PubMed]
- De-Deus, G.; Namen, F.; Galan, J.; Zehnder, M. Soft chelating irrigation protocol optimizes bonding quality of resilon/Epiphany root fillings. J. Endod. 2008, 34, 703–705. [Google Scholar] [CrossRef] [PubMed]
- Moon, Y.M.; Kim, H.C.; Bae, K.S.; Baek, S.H.; Shon, W.J.; Lee, W.C. Effect of laser-activated irrigation of 1320-nanometer Nd:YAG laser on sealer penetration in curved root canals. J. Endod. 2012, 38, 531–535. [Google Scholar] [CrossRef]
- Arora, S.; Hegde, V. Comparative evaluation of a novel smart-seal obturating system and its homogeneity of using cone beam computed tomography: In vitro simulated lateral canal study. J. Conserv. Dent. 2014, 17, 364–368. [Google Scholar] [CrossRef] [Green Version]
- Metzger, Z.; Solomonov, M.; Kfir, A. The role of mechanical instrumentation in the cleaning of root canals. Endod. Top. 2013, 29, 87–109. [Google Scholar] [CrossRef]
- Neelakantan, P.; Varughese, A.A.; Sharma, S.; Subbarao, C.V.; Zehnder, M.; De-Deus, G. Continuous chelation irrigation improves the adhesion of epoxy resin-based root canal sealer to root dentine. Int. Endod. J. 2012, 45, 1097–1102. [Google Scholar] [CrossRef]
- Bergmans, L.; Van Cleynenbreugel, J.; Wevers, M.; Lambrechts, P. Mechanical root canal preparation with NiTi rotary instruments: Rationale, performance and safety. Status Report for the American Journal of Dentistry. Am. J. Dent. 2001, 14, 324–333. [Google Scholar]
- Resende, L.M.; Rached-Junior, F.J.; Versiani, M.A.; Souza-Gabriel, A.E.; Miranda, C.E.S.; Silva-Souza, Y.T.C.; Souza Neto, M.D. A comparative study of physicochemical properties of AH Plus, Epiphany, and Epiphany SE root canal sealers. Int. Endod. J. 2009, 42, 785–793. [Google Scholar] [CrossRef] [PubMed]
- Martins, J.; Silva, E.; Marques, D.; Belladonna, F.; Simões-Carvalho, M.; Camacho, E.; Braz Fernandes, F.; Versiani, M. Comparison of design, metallurgy, mechanical performance and shaping ability of replica-like and counterfeit instruments of the ProTaper Next system. Int. Endod. J. 2021, 54, 780–792. [Google Scholar] [CrossRef]
- Nagas, E.; Cehreli, Z.; Uyanik, M.O.; Durmaz, V. Bond strength of a calcium silicatebased sealer tested in bulk or with different main core materials. Braz. Oral. Res. 2014, 28, 1–7. [Google Scholar] [CrossRef] [Green Version]
- Jainaen, A.; Palamara, J.E.A.; Messer, H.H. Push-out bond strengths of the dentine-sealer interface with and without a main cone. Int. Endod. J. 2007, 40, 882–890. [Google Scholar] [CrossRef] [PubMed]
- Saleh, I.M.; Ruyterm, I.E.; Haapasalo, M.; Orstavik, D. The effects of dentine pretreatment on the adhesion of root-canal sealers. Int. Endod. J. 2002, 35, 859–866. [Google Scholar] [CrossRef] [PubMed]
- Neelakantan, P.; Sharma, S.; Shemesh, H.; Wesselink, P.R. Influence of irrigation sequence on the adhesion of root canal sealers to dentin: A fourier transform infrared spectroscopy and push-out bond strength analysis. J. Endod. 2015, 41, 1108–1111. [Google Scholar] [CrossRef] [PubMed]
- Neelakantan, P.; Nandagopal, M.; Shemesh, H.; Wesselink, P. The effect of root dentin conditioning protocols on the push-out bond strength of three calcium silicate sealers. Int. J. Adhes. Adhes. 2015, 60, 104–108. [Google Scholar] [CrossRef]
- Razmi, H.; Bolhari, B.; Karamzadeh Dashti, N.; Fazlyab, M. The effect of canal dryness on bond strength of bioceramic and Epoxy-resin sealers after irrigation with Sodium Hypochlorite or Chlorhexidine. Iran. Endod. J. 2016, 11, 129–133. [Google Scholar]
- Velozo, C.; Silva, S.; Almeida, A.; Romeiro, K.; Vieira, B.; Dantas, H.; Souza, F.; De Albuquerque, D. Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: A micro-computed tomography study. Int. Endod. J. 2020, 53, 998–1006. [Google Scholar] [CrossRef]
- Kfir, A.; Moza-Levi, R.; Herteanu, M.; Weissman, A.; Wigler, R. Apical extrusion of debris during the preparation of oval root canals: A comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file. Clin. Oral. Investig. 2018, 22, 707–713. [Google Scholar] [CrossRef]
- Pawar, A.M.; Pawar, B.A.; Bhardwaj, A.; Luke, A.M.; Metzger, Z.; Kfir, A. Apical debris extrusion by adaptive root canal instrumentation in oval canals: Full-sequence SAF system vs. the XP-endo shaper plus sequence. Appl. Sci. 2020, 10, 5684. [Google Scholar] [CrossRef]
- Pawar, B.A.; Pawar, A.M.; Bhardwaj, A.; Wahjuningrum, D.A.; Rahardjo, A.K.; Luke, A.M.; Metzger, Z.; Kfir, A. Effect of adaptive, rotary, and manual root canal instrumentation in primary molars: A triple-armed, randomized controlled clinical trial. Biology 2021, 10, 42. [Google Scholar] [CrossRef]
- Pawar, A.M.; Bhardwaj, A.; Banga, K.S.; Singh, G.; Kfir, A.; Luke, A.M.; Dinata, V.; Wahjuningrun, D.A. Deficiencies in root canal fillings subsequent to adaptive instrumentation of oval canals. Biology 2021, 10, 1074. [Google Scholar] [CrossRef]
Method | SN | PUI | SA | |||
---|---|---|---|---|---|---|
GP-AH | C-EBC | GP-AH | C-EBC | GP-AH | C-EBC | |
PTN | 1.4 ± 0.3 † a, A | 1.6 ± 0.3 a, A | 1.7 ± 0.3 a, A | 2.0 ± 0.6 a, A | 1.6± 0.3 a, A | 1.9 ± 0.4 a, A |
WO | 1.8 ± 0.3 a, A | 3.1 ± 0.4 b, B | 2.0 ± 0.3 a, A | 3.3 ± 0.3 b, B | 1.9 ± 0.2 a, A | 3.1 ± 0.4 b, B |
SAF | 2.9 ± 0.5 b, A | 4.6 ± 0.5 c, B | 3.0 ± 0.7 b, A | 4.9 ± 0.3 c, B | 2.5 ± 0.3 b, A | 4.2 ± 0.5 c, B |
Method | PTN | Total Specimens | |||||
---|---|---|---|---|---|---|---|
SN | PUI | SA | |||||
GP-AH | C-EBC | GP-AH | C-EBC | GP-AH | C-EBC | ||
Adhesive | 70 (7) | 60 (6) | 50 (5) | 40 (4) | 50 (5) | 40 (4) | 60 |
Cohesive | 10 (1) | 30 (3) | 20 (2) | 30 (3) | 30 (3) | 20 (2) | |
Mixed | 20 (2) | 10 (1) | 30 (3) | 30 (3) | 20 (2) | 40 (4) | |
WO | |||||||
Adhesive | 60 (6) | 60 (6) | 60 (6) | 50 (5) | 50 (5) | 40 (4) | 60 |
Cohesive | 20 (20) | 10 (1) | 30 (3) | 20 (2) | 30 (3) | 30 (3) | |
Mixed | 20 (20) | 30 (3) | 10 (1) | 30 (3) | 20 (2) | 30 (3) | |
SAF | |||||||
Adhesive | 10 (1) | 00 (0) | 00 (0) | 00 (0) | 20 (2) | 00 (0) | 60 |
Cohesive | 70 (7) | 30 (3) | 60 (6) | 20 (2) | 70 (7) | 30 (4) | |
Mixed | 20 (2) | 70 (7) | 40 (4) | 80 (8) | 10 (1) | 70 (7) |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Pawar, A.M.; Kfir, A.; Metzger, Z.; Bhardwaj, A.; Yohana, Y.; Wahjuningrun, D.A.; Luke, A.M.; Pawar, B.A. Can Type of Instrumentation and Activation of the Final Irrigant Improve the Obturation Quality in Oval Root Canals? A Push-Out Bond Strength Study. Biology 2022, 11, 59. https://doi.org/10.3390/biology11010059
Pawar AM, Kfir A, Metzger Z, Bhardwaj A, Yohana Y, Wahjuningrun DA, Luke AM, Pawar BA. Can Type of Instrumentation and Activation of the Final Irrigant Improve the Obturation Quality in Oval Root Canals? A Push-Out Bond Strength Study. Biology. 2022; 11(1):59. https://doi.org/10.3390/biology11010059
Chicago/Turabian StylePawar, Ajinkya M., Anda Kfir, Zvi Metzger, Anuj Bhardwaj, Yeyen Yohana, Dian Agustin Wahjuningrun, Alexander Maniangat Luke, and Bhaggyashri A. Pawar. 2022. "Can Type of Instrumentation and Activation of the Final Irrigant Improve the Obturation Quality in Oval Root Canals? A Push-Out Bond Strength Study" Biology 11, no. 1: 59. https://doi.org/10.3390/biology11010059
APA StylePawar, A. M., Kfir, A., Metzger, Z., Bhardwaj, A., Yohana, Y., Wahjuningrun, D. A., Luke, A. M., & Pawar, B. A. (2022). Can Type of Instrumentation and Activation of the Final Irrigant Improve the Obturation Quality in Oval Root Canals? A Push-Out Bond Strength Study. Biology, 11(1), 59. https://doi.org/10.3390/biology11010059