Article

A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles

1
Team Fire Service Science, Netherlands Academy of Crisis Management and Fire Service Science, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands
2
Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Box 118, 22100 Lund, Sweden
3
Team COLS, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands
*
Author to whom correspondence should be addressed.
Biology 2022, 11(12), 1813; https://doi.org/10.3390/biology11121813
Submission received: 14 November 2022 / Revised: 2 December 2022 / Accepted: 6 December 2022 / Published: 13 December 2022
(This article belongs to the Special Issue Effects of Environmental Factors on Human Health and Performance)

Abstract

:

Simple Summary

Rescue services personnel may be exposed to a wide range of harsh environments that require the use of protective gear. In order to achieve the best performance, the optimal protection for specific incident scenarios should be selected. In order to be able to specify the protective clothing ensemble that best matches the protection needs, activity and environmental conditions, while keeping up the performance and reduce impact of thermal stress, we need to know the clothing properties that affect heat transfer via the protective layers. The thermal insulation and evaporative resistance values of firefighter clothing items and ensembles of the whole protective system are not easily available. The work presented in this paper fills this gap. Collected data allow for validation and selection of prediction models for exposure evaluation, and with this, it contributes to the best performing protective ensemble choice for specific incident scenarios. The paper also presents the relationships for summing individual clothing items’ insulation of the firefighter protective clothing system and therefore reduces the need for separate testing of all possible clothing ensemble configurations. The wide literature background allows for extrapolation of the results to other branches where protective clothing is used.

Abstract

The rescue operations’ environment can impair firefighters’ performance and increase the risk of injuries, e.g., burns and hyperthermia. The bulk and carried weight of heavy protection contributes to lower physical performance, higher metabolic load and internal body heat production. For recommending optimal protection for the tasks and incident scenarios, knowledge of clothing thermal properties is needed. However, detailed data on firefighter protective clothing systems are not available. The aim of the study was to provide scientific background and a dataset that would allow for validation of thermo-physiological models for task-specific conditions of rescue work. Thermal insulation of 37 single items and their variations and 25 realistic protective clothing ensembles were measured on a thermal manikin. Twelve (12) ensembles that evenly covered the whole insulation range were selected for evaporative resistance testing. The equations for summing up individual item’s insulation to ensemble insulation and calculating clothing area factor were derived from the dataset. The database of a firefighter clothing system was created. In addition, the local and regional thermal properties of the clothing ensembles were provided for use in future validation of advanced thermo-physiological models for rescue worker exposure predictions and for designing decision aid tools.

1. Introduction

During rescue operations, the environment can impair firefighters’ performance and increase the risk of injuries such as burns [1,2] and hyperthermia [3,4,5]. The firefighter ensembles offer high protection levels. However, increased protection also increases the bulk and carried weight that means lower physical performance, higher metabolic load and internal body heat production [6,7,8]. Reduced mobility, flexibility, and dexterity may also restrict the ability to successfully accomplish a task [9,10,11,12]. Therefore, an objective aim of firefighter organizations is being able to select optimal protection for the tasks and incident scenarios.
In the Netherlands, the fire services are currently switching to a new station wear, called operational uniform (OU) for low-risk tasks. It is very important to look at how firefighters can in the future be optimally protected within the entire risk spectrum of both low-risk and high-risk tasks. A current limitation is an insufficient database and knowledge about the thermal properties of firefighter protective clothing items and systems. There is currently no coordination of (protective) clothing packages in use for operational tasks. At every alarm, the protective clothing for firefighting is put on, with or without the current station uniform, or in the future, on the operational uniform. For volunteer firefighters, often, only the protective clothing for firefighting is available, and this is worn over their daily clothing. Risk profiles, protection requirements and wearing comfort play an important role in order to arrive at the protection concept that is best suited to the tasks. It is desirable that such a protection concept leaves space for integration of future developments.
With regard to functionality and protection, the minimum level has been established and formalized by means of (inter)national standards (NEN-EN and ISO) [13,14,15,16,17,18,19,20,21,22]. However, most of the requirements are related to materials and material packages and not for the complete items or clothing ensembles. The current clothing systems in use are combined where possible and should ultimately lead to a fully integrated protective clothing system, of which digital support can be a part, for example, mobile applications, such as ClimApp [23,24] and decision aids [25,26]. In the future, possibly, the clothing system can be combined with the necessary sensors and smart solutions to acquire real-time input from the incident site to allow for the optimal selection of gear. Firefighters have to be adequately protected for the tasks they have to perform, whereby each task may require specific protection. An aim is that the clothing can be built up by modules into an integral protection concept. Modularity in clothing systems may also support sustainable development with easier inspection, care and maintenance of the gear, allowing for replacement of worn out items and longer lasting of the whole protective clothing system.
Clothing insulation and evaporative resistance are the basic clothing parameters that affect human heat exchange with the environment. They are used as a common behavioural thermoregulatory measures and are means to maintain thermal comfort in a wide range of temperatures [27]. Commonly, these properties are not evenly distributed over the whole body surface due to the material choice, clothing design, layering, fit, etc. Physiological parameters, such as heat generation in muscles of different body parts during different work tasks, body internal heat distribution and areas for heat loss [28,29], protection criteria of vital regions, sweating patterns [30,31,32], but also freedom of motion, may set the specific demands on the need of regional evaporative resistance [33] and clothing insulation [34]. Clothing parameters for body regions can be measured, and the change due to walking and wind can be estimated [35,36,37,38]. Local values can be used in advanced physiological models for exposure evaluation [26,39,40,41,42,43,44], for occupational health and safety purposes, as a feedback for clothing manufacturers for improving their products, and/or for industries for selecting the clothing provided to their employees. In addition, some publications provide information on how to count for fit, garment size and/or airgaps [37,43,45,46].
The methods to measure or estimate clothing items’ or their combinations’ insulation [47,48,49,50] and evaporative resistance [51,52] are standardized, or detailed suggestions for testing and data treatment are available [53]. ISO 9920 [50] contains databases on clothing items and ensembles based on earlier studies [54,55,56], and presents algorithms to sum individual items, calculate effect of wind and motion, etc. Despite the extensive content of this standard [50], it has a limited coverage of different clothing styles other than Western office and workwear, while recent publications cover that gap [57,58,59]. Another problem is that the majority of the standard’s database was compiled mainly around 1980s, and both the design and the materials have changed. This has now been overcome by many recent studies on modern office and casual clothing that have been measured using the latest technology and providing detailed information on different aspects of clothing thermal performance [36,37,38,39,42,43,60,61,62,63]. At the same time, when modern office and casual clothing are measured in a systematic way, data on industrial workwear are not as easily available. Some exceptions are studies on military [64,65,66,67,68,69], ambulance [70,71], cold protective [72,73,74,75,76,77], and some agricultural [78,79] clothing systems. Although, the studied clothing systems cover a wide variety of clothing configurations, it may be suspected that specialized clothing, e.g., the ones used by firefighters, may behave differently due to the protective layers and their combinations. Considering any future developments in clothing science and advanced support systems [23,25,26], and to select the best suited protection for any incident scenario in high stress situations quickly, more detailed information on thermal properties of clothing that is used by rescue workers is needed. As it is quite impossible to measure all possible clothing combinations used in the field, it is important to create an individual clothing items’ wardrobe database based on manikin measurements. Development and/or validation of specific clothing insulation and evaporative resistance summation methods that match the selected clothing system would allow for evaluation of human exposure and to select the proper protection over a wide range of environments and working conditions [23,26,40,78,80,81,82,83,84,85].
This work aimed to create a detailed firefighter clothing database of static thermal insulation values of the individual clothing items, some PPE items, and their combinations that are the elements of Dutch firefighter station wear (operational uniform) and incident scenario-based turnout gear. An aim was also to report the static thermal insulation of realistic clothing ensembles of station wear and turnout gear and evaporative resistance of selected clothing ensembles. As the collected material is quite extensive, local insulation and evaporative resistance values of the clothing ensembles for various body regions that may be useful for advanced thermo-physiological modelling are included in Appendix A and Appendix B (Table A1 and Table A2, respectively). The items’ and ensembles’ thermal properties are ranked and visualized in Appendix C (Figure A1, Figure A2 and Figure A3).

2. Materials and Methods

2.1. The Thermal Manikin Tore

In this study, all items were tested individually or in combinations on the thermal manikin Tore at the Thermal Environment Laboratory, Lund University. Tore is a male-shaped thermal manikin [86,87]. Tore is made of orthopaedic foam with a metal frame inside to support the body parts and for joints. Tore is divided into 17 individually controlled zones: head, chest, back, stomach, buttocks, left and right upper arm, left and right lower arm, left and right hand, left and right thigh, left and right calf, and left and right foot. The weight of the manikin is 32 kg. The surface temperature of the manikin’s zones was controlled at 34 °C. Thermal manikin Tore and the used climatic chamber have been used in multiple joint studies and interlaboratory trials, and comparative data with the other manikins and test environments are well available over the wide range of clothing types, postures, walking and wind velocities, and for the variety of purposes, e.g., for thermal insulation [58,63,72,88], evaporative resistance [89], for thermo-physiological modelling [90], and as a part of evaluation of occupational incident [91], cooling systems [92,93], etc.

2.2. Manikin Calibration

Offset calibration of the manikin’s surface temperature sensors was carried out in the homogenous conditions (34 °C) in a warm chamber with the same Pico equipment that was used for air temperature measurements, as described in Section 2.4. Calibration procedures followed ISO 15831 [49].

2.3. Measurements of Clothing Surface Area Factor (fcl)

Photographic method based on 2 photos was used to estimate clothing area factor (fcl) of the individual garments and the ensembles [52,58]. The frontal and the side photos were used.

2.4. Thermal Insulation Measurements

The tests for total thermal insulation (IT) were carried out on the manikin in a standing position according to ISO 15831 [49] following ISO 9920 [50] recommendations (low air velocity). The basic (intrinsic) insulation of each garment item (Iclu) and clothing ensemble (Icl) was calculated. The mean air velocity was measured with Swema Air 3000d logger with omnidirectional SWA03 sensor 7 Air velocity in the chamber stayed on average at 0.18 ± 0.07 m/s. It was originally measured as an average of 15 points in air flow 50 cm before the manikin and then checked in the control position at the end of each individual test. Air layer insulation (Ia) was measured with a nude manikin in the same conditions. It has been shown that the calculation method (parallel or serial) may strongly affect the result [76,94,95,96,97]. When testing highly insulative and less permeable clothing, the manikin heat loss from some zones, especially in the areas with many overlapping layers, e.g., buttocks, abdomen, may drop close to zero, and local temperature may rise above the set temperature. Therefore, the principles of global method [76,97] that are insensitive for such technical effects and are also more reliable for correlating with human exposures, were utilized in the calculations.
The air temperature in the climate chamber was set to 20 °C for individual items and light clothing combinations and to 10 °C for heavy protective combinations. Air temperature variation during the stable state was below 0.1 °C. Ambient air temperature was continuously monitored using three sensors (PT 100, Pico Technology Ltd., St. Neots, UK) positioned adjacent to the ankles, the mid-trunk, and the head (vertical heights of 0.1, 1.1, and 1.7 m from the soles of the manikin). The mean radiant temperature was equal to the air temperature. The temperatures and heat losses were recorded at ten-second intervals. The last 10 min of stable state was used for thermal insulation calculation.

2.5. Evaporative Resistance Measurements

The total evaporative resistance (Ret) of selected clothing ensembles was measured according to ASTM F2370-16 [51] on the manikin in standing position under so-called isothermal conditions set to 34 °C. Both the mass loss and heat loss methods were used for further analysis, but as comparable local evaporative resistances of body regions could only be based on heat loss, only the results from the heat loss method are presented in this paper. Average air velocity during these tests was 0.40 ± 0.13 m/s. Data for the whole measuring period (commonly up to 70 min) were saved. Based on the weight change, temperature and heat loss curves, the stable periods, meaning constant evaporative heat loss, were selected for evaporative resistance calculation. Relative humidity was measured with the Humidity Sensor Evaluation Kit EK-H3 with pin SHT75 sensors (Sensirion AG, Stäfa, Switzerland). Relative humidity in the chamber was set to 40%. During the stable state of each measurement, the variation in the relative humidity was less than 2%. The corrections according to Wang et al. [98] were applied to the measured evaporative resistance values. Any further corrections, e.g., for skin material and moist skin insulation, etc. [52,53,99,100,101], were not used. The further comparisons between different available corrections [53,102] will be presented in a separate paper. Finally, clothing evaporative resistance (Recl) and permeability indices (im and im,cl) were calculated.

2.6. Calculations

Total insulation of an individual zone (IT,i, m2K/W):
I T , i = T s , i T o × A i H c , i ,
where Ts,i—mean surface temperature of a manikin zone i (°C); To—operative temperature (°C); Ai—area of a manikin zone i (m2); Hc,i—dry heat loss from a manikin zone i (W).
An individual zone insulation as a contribution to the whole body insulation (IT,i,r, m2K/W):
I T , i , r = A i A × T s , i T o × A i H c , i ,
where A—area of the whole manikin surface (m2).
Total insulation for a body zone group (IT,z,i, m2K/W):
I T , z , i = ( T s , i × A i ) / A z , i n T o ) × A z , i n H c , z , i n ,
where A z , i n —area of all manikin zones included in the group (m2); H c , z , i n —dry heat loss from all manikin zones included in the group (W).
Total insulation for the whole body (IT, m2K/W):
I T = ( T s , i × A i ) / A T o ) × A H c , i .
Basic (intrinsic) clothing insulation of an item (Iclu, m2K/W) or an ensemble (Icl, m2K/W):
I clu = I cl = I T I a f cl ,
where Ia—air layer insulation (measured on the nude manikin, m2K/W); fcl—clothing area factor (n.d.).
Water vapour pressure at manikin surface temperature (Pa):
p s = e 18.956 4030 T s + 235 × R H sk ,
where Ts—mean surface temperature of a manikin (°C); RHsk—relative humidity at manikin (textile) skin temperature (%).
Manikin surface temperature (°C):
T s = T s , i × A i A .
Water vapour pressure at textile skin temperature (Pa):
p sk = e 18.956 4030 T sk + 235 × R H sk ,
where Tsk—mean (textile) skin temperature of a manikin (°C), and where mean RHsk over the various conditions irrespective of the clothing combination was 96%.
T sk = T sk , i × A i A ,
where Tsk,i—mean (textile) skin temperature of a manikin zone i (°C).
Correction of the manikin skin temperature [98,100] (depends on “skin” properties):
T sk , i = T s , i 0.0132 × Q i ,
where Qi—heat flux from a manikin zone i (W/m2).
Water vapour pressure in the air (Pa):
p a = e 18.956 4030 T a + 235 × R H a ,
where Ta—air temperature (°C); RHa—relative air humidity (%).
Total evaporative resistance of a zone (m2Pa/W):
R et , i = p sk , i p a × A i H i ,
where psk,i—water vapour pressure at (textile) skin of a manikin zone i (Pa); Hi—heat loss from a manikin zone i (W).
Heat flux (W/m2):
Q = H i A i .
Uncorrected evaporative resistance (m2Pa/W):
R et , raw = p s p a H e , i × A i A ,
where He,i—assumed evaporative heat loss from a manikin zone i (W).
The assumption here is that conductive, convective and radiative heat exchange is close to zero, and the test is carried out at the isothermal conditions (Ta = Ts = Tsk), i.e., the only heat exchange pathway is evaporation.
Total evaporative resistance corrected for water vapour pressure at skin temperature (m2Pa/W):
R et = p sk p a H e , i × A i A ,
Clothing evaporative resistance (m2Pa/W):
R ecl = R et R ea f cl ,
where Rea—air layer evaporative resistance (measured with textile skin, m2Pa/W).
Moisture permeability index (n.d.):
i m = I T R et × L ,
where L—Lewis relation (16.5 × 10−3 K/Pa).
Clothing moisture permeability index (n.d.):
i m , cl = I cl R ecl × L .
Relationship between clo and m2K/W:
1 clo = 0.155 m2K/W.

2.7. Clothing

In total, 37 individual items or their variations (see Table 1 for images and description) and 25 clothing ensembles were measured including 150 dry measurements for thermal insulation and 36 wet measurements for evaporative resistance of 12 selected ensembles (see Table 2 for description and Table 3 for images). Each item and combination was tested at least twice. If the difference of two measurements was above 4%, then the measuring settings were checked, and additional measurements were carried out. In addition, the tested items and clothing combinations were photographed from front and side for documentation purposes and for clothing area factor (fcl) calculations. All the items were weighed.

3. Results and Discussion

The specifications and the insulation measurement results for the individual items (IT, Iclu) are shown in Table 1. Figure A1 in Appendix C visualizes the individual items’ basic insulation ranked by the item group and/or body coverage region, e.g., feet, hands, head, underwear, shirts, jackets and their variations, etc. Table 2 presents the thermal insulation of the tested clothing ensembles (IT, Icl), the evaporative resistances (Ret,raw, Ret, Ret,cl) and permeability indices (im, im,cl) of the selected clothing ensembles. In addition, the measured clothing area factors (fcl) for individual items and the clothing ensembles are given in Table 1 and Table 2, respectively. Table 3 presents the pictures of the clothing ensembles. Table A1 of Appendix A shows the thermal insulation and Table A2 of Appendix B the evaporative resistance values of the individual body zones and body regions.

3.1. Relationship between Measured and Summed Basic Clothing Insulation (Icl)

If the standard method for summing up the individual clothing items’ insulation [50] fit practically perfectly for the ambulance clothing system [50,70], then the firefighter clothing system tested in the present study differed clearly in this respect, creating two groups. For the operational uniform (OU) ensembles, the standard summation method overestimated the actual insulation (Figure 1a), and for the incident clothing systems, it underestimated the insulation (Figure 1b). It may be expected that the basic clothing insulation range between 1.4 and 2 clo can be predicted well; however, there were no ensembles in the range from 1.6 to 1.9 clo. When these OU and incident clothing groups were separated, then for clothing ensembles that covered incident scenarios, it was enough to adjust the intercept of the standard equation to acquire a reasonable prediction (Equation (20), Figure 1b).
I cl = 0.311 + 0.835 × I clu .
When the OU ensembles are above 1.3–1.4 clo, the prediction (summation) may be considered as a reasonable match (Figure 1); then, for lighter clothing ensembles, the overestimation by summation is bigger. For OU ensembles, a better matching relationship had to be developed (R2 = 0.993, Equation (21), Figure 1a):
I cl = 0.975 × I clu 0.194 .

3.2. Clothing Surface Area Factor (fcl)

As in an earlier study on ambulance clothing [71], for firefighter clothing systems, a wide variety of available equations for fcl calculation were utilized. The best estimations were not the ones derived specifically for a dedicated clothing system based on a layer-by-layer approach [71] for a winter clothing system [103] or estimation equations based on a wider database [50], but instead according to the recent estimation for a modern Western clothing database [63] (R2 = 0.978, Figure 2), possibly indicating similar trends in fashion:
f cl = 1.01 + 1.599 × I cl .
The specific equation for clothing area factor estimation (R2 = 0.978; Icl in clo) for this clothing system was
f cl = 1.02 + 0.2314 × I cl .
Any further tests with other firefighter clothing ensembles may need to prove if the equations above also fit in general with those. Those combinations with the respiratory protective system (SCBA) did not specifically stand out from the general variation, neither for clothing area factor estimation nor for the basic clothing insulation summation method.

3.3. The Use of Collected Data

The outcome of the individual items and garment ensembles measurements allows us to evaluate the effects of (a) variation in individual items and their combinations, (b) ways of dressing, and (c) design solutions. Gathering specific basic data on firefighter clothing systems allowed us to adjust the clothing summation method for improved prediction accuracy when selecting and recommending the clothing combinations. The basic data on clothing evaporative resistance give us improved prediction accuracy when selecting and recommending the clothing combinations. In combination with input from other relevant research in this area [26,37,42,43,104,105,106,107], the collected data allow us to model the exposure to a variety of incident scenarios in the presently available clothing systems, and most importantly, validate those available models for rescue services incident scenarios and exposure conditions if the experimental data with the same or similar clothing systems will be available.
As insulation and evaporative resistance values of all individual body parts and body areas are also available (see Appendix A and Appendix B), there is a possibility to (a) use these datasets in advanced thermo-physiological models to obtain more detailed predictions; (b) find weak areas in the clothing systems and suggest improvements in clothing design; (c) perform more accurate exposure predictions for improved purchase support. However, experimental data have to be collected for proper model selection and validation. Knowing the clothing properties will greatly assist in decision making in relation to extreme weather events and indoor exposures [23,24]. In the same way, exposure to indoor (office) environments can be estimated according to ISO 7730 [82]. This standard introduces PMV (predicted mean vote) and PPD (predicted percentage of dissatisfied) indexes that relate the environmental parameters to thermal responses of the exposed population. However, the tools are not easily available for much more extreme exposure conditions that the firefighters face.

4. Conclusions and Future Perspectives

The work of this paper aimed to evaluate the thermal properties of the presently used firefighter clothing systems. Some complementary evaluations should be performed further on, for example: measuring body motion (walking) effects on manikins and the effects of higher air velocity and the combinations of these factors to estimate ventilation effects in the clothing systems. A separate line of research on firefighter clothing systems is the continued information collection and material testing for the effects of heat radiation levels.
Additionally, some common ways of wearing presently used garments should be tested, e.g., front zip open/closed/partly closed, Velcro or rubber bands at wrists or ankles tightened or loose, in order to collect more information on clothing performance for future design solution selection. In addition, the effects and usefulness of available cooling solutions [108] should be evaluated for firefighter use, taking into account logistical challenges. Further, testing of specific design solutions/ideas, including the effects of smart functions, must be considered in order to support the development of standards that are able to cover evaluation and certification needs of the new technical solutions so that they can safely be taken into use by the rescue services [109,110].
As many simple, but also advanced, thermo-physiological models do not support exposure to extreme environmental conditions or highly protective clothing (including impermeable layers), after checking the capacities of existing advanced models [40,44], the needs for improving the prediction models must be settled. Such validation requires considerable experimental work with human subjects. However, the use of such validated models allows us to evaluate clothing design solutions before and under prototyping phases and to diminish the need of later testing on human subjects and minimize costs on changes. At the same time, testing the protective clothing systems for compatibility and ergonomics is still needed [111,112].
The basic data on the present clothing system were collected, and the database was created. This allows us to proceed with:
  • Selection and recommendations of clothing combinations for the best performance and comfort under specific exposure conditions;
  • Evaluation of the design aspects of the protective clothing and protective clothing systems;
  • Modelling and prediction model validation, and the comparison of their deviation from human responses in realistic conditions with human subjects;
  • Supporting the development of the firefighter’s modular protective clothing system of the future;
  • Developing digital decision support tools for rescue services’ purposes;
  • Creating educational and demonstration materials for optimal protection selection.

Author Contributions

Conceptualization, K.K., M.K. and R.H.; methodology, K.K.; formal analysis, K.K. and J.E.; investigation, K.K., J.E. and M.K.; resources, M.K. and K.K.; data curation, K.K. and J.E.; writing—original draft preparation, K.K.; writing—review and editing, K.K., J.E. and R.H.; visualization, K.K., J.E. and M.K.; supervision, K.K.; project administration, K.K. and M.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

The authors appreciate the input of Chuansi Gao for facilitating this study.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

Table A1. Clothing ensembles’ local and regional clothing insulation values (IT,i, IT,z,i, m2K/W).
Table A1. Clothing ensembles’ local and regional clothing insulation values (IT,i, IT,z,i, m2K/W).
CodeHeadChestBackAbdomenButtocksTorsoUpper ArmsLower ArmsArmsHandsThighsCalvesLegsFeetHead, Hands and Feet Excluded
AL0.1060.1130.0970.0950.0760.0970.1190.1050.1130.1010.0970.0820.0900.1080.097
C10.1010.2790.2510.3040.2670.2630.2110.1040.1560.1010.2300.1740.2010.2640.207
C1A0.0980.4130.3880.4690.4720.4190.3600.2320.3020.1000.2550.1860.2220.2680.294
C1B0.1050.4510.4050.5200.4980.4480.3680.2440.3120.1030.2600.1910.2270.2700.305
C20.1010.2380.2140.3290.2850.2460.2780.2050.2470.1170.2460.1790.2140.2670.233
C2A0.0990.3870.3470.5310.4380.3970.3850.2780.3370.1100.2540.1750.2150.2660.292
C2B0.0980.3890.3570.5260.4550.4040.3940.2870.3450.1220.2530.1740.2140.2730.294
C2C0.1010.4560.4250.6390.5740.4800.4110.2950.3600.1120.2450.2080.2280.2850.321
C2D0.1550.4680.3420.5970.5000.4310.4350.3380.3910.1230.2480.2060.2280.2820.317
C2E0.2110.4610.3400.5970.4960.4270.4390.3380.3940.1240.2480.2050.2280.2840.316
C2F0.1660.5810.5080.6800.6800.5770.6020.4840.5500.1210.2420.2090.2260.2740.361
C2G0.1570.6260.5540.7420.7020.6230.6240.4890.5600.1360.2450.2060.2270.2840.370
C30.1010.2800.2480.4430.4530.3020.3290.2610.2990.1550.2410.1800.2110.2750.259
C3A0.1430.2690.2320.4270.4110.2860.3140.2380.2800.1520.2310.2020.2180.2680.255
C3B0.1450.4140.3780.6010.5980.4420.4100.2970.3580.1230.2490.2190.2350.2720.319
C40.1060.1130.0970.0950.0760.0970.1190.1050.1130.1010.0970.0820.0900.1080.097
C50.2070.6700.5340.5850.5290.5810.5510.3890.4800.2620.5450.4390.4970.3410.523
C60.2070.7300.5290.7930.7640.6570.5780.4190.5060.2590.6020.4210.5140.3450.560
C6A0.2810.6440.5420.7300.6220.6140.5220.3920.4660.2640.6130.4250.5210.3480.539
C6B0.3150.6540.5200.7220.6080.6030.5200.4020.4700.2800.6310.4320.5330.3520.542
C6C0.2720.6420.5490.7200.5790.6070.5000.4130.4620.2580.5970.4180.5100.3420.531
C70.2070.8120.6230.8420.7830.7350.5350.4190.4850.2550.6130.4260.5210.3500.578
C80.1980.6260.4540.7170.7340.5760.4710.3870.4370.2500.5850.4240.5070.3440.513
C90.1550.5450.4110.7770.7720.5370.4010.3490.3790.1550.5650.4260.4990.3400.478
C9A0.1530.6640.4470.7960.7340.5900.4790.3900.4410.1470.5860.4330.5140.3510.521
C9B0.1540.6380.4360.7270.7770.5740.4680.3880.4350.2470.5900.4260.5110.3480.513

Appendix B

Table A2. Selected clothing ensembles’ local and regional evaporative resistances (m2Pa/W, correction acc. to Wang et al., 2010).
Table A2. Selected clothing ensembles’ local and regional evaporative resistances (m2Pa/W, correction acc. to Wang et al., 2010).
CodeAllHeadChestBackAbdomenButtocksTorsoUpper ArmsLower ArmsArmsHandsThighsCalvesLegsFeetHead, Hands and Feet ExcludedHands and Feet ExcludedHands Excluded
SK8.08.09.59.56.09.78.79.57.68.75.36.710.37.86.48.48.38.2
C118.78.921.818.736.927.923.119.98.113.76.026.521.724.3107.120.518.820.3
C1A31.59.866.063.574.048.562.565.844.755.98.228.121.524.9102.440.233.335.2
C222.09.624.618.539.329.324.226.517.722.89.028.621.225.0106.724.221.823.5
C2A29.38.960.067.178.644.061.366.953.961.76.223.622.723.197.338.931.833.6
C2D41.816.8161.9112.1184.753.6112.894.385.689.610.827.027.927.0113.251.945.047.3
C2G44.317.9179.2129.9151.964.6124.8124.194.4110.714.623.230.525.3105.852.846.248.5
C3B38.213.787.483.5118.954.282.671.650.960.411.930.027.728.787.447.140.142.0
C481.444.6139.6101.8134.6124.3120.785.271.979.941.184.175.478.994.091.784.785.3
C670.622.8114.177.2133.3100.698.088.777.984.346.179.873.476.096.785.371.072.5
C6A83.648.7115.6112.8134.1121.3117.989.777.484.742.782.876.778.5111.492.286.087.6
C872.624.5112.173.8183.9110.4100.471.265.368.851.081.097.085.3108.885.772.274.1
C9A59.416.3107.768.3144.4109.993.569.061.466.022.479.675.277.1101.279.662.464.2

Appendix C. Visualisation and Ranking of Measured Insulation and Evaporative Resistance Values

Figure A1. Basic clothing insulation of the tested items (Iclu, clo). As the firefighter coverall had over 2 times higher basic insulation, the y-axis scale was not extended to that level, but the value (1.52 clo) is given above the top of this column. Alternating colour shade groups differentiate between product groups and/or body regions covered by these items, e.g., feet (socks, shoes), hands (gloves) head, SCBA element variations, etc.
Figure A1. Basic clothing insulation of the tested items (Iclu, clo). As the firefighter coverall had over 2 times higher basic insulation, the y-axis scale was not extended to that level, but the value (1.52 clo) is given above the top of this column. Alternating colour shade groups differentiate between product groups and/or body regions covered by these items, e.g., feet (socks, shoes), hands (gloves) head, SCBA element variations, etc.
Biology 11 01813 g0a1
Figure A2. Measured (Icl (meas)) and summed (Icl (sum, ISO 9920)) basic clothing insulation of all ensembles (Icl, clo) with their relative differences (Diff(%)). For clothing combination descriptions see Table 1, Table 2 and Table 3.
Figure A2. Measured (Icl (meas)) and summed (Icl (sum, ISO 9920)) basic clothing insulation of all ensembles (Icl, clo) with their relative differences (Diff(%)). For clothing combination descriptions see Table 1, Table 2 and Table 3.
Biology 11 01813 g0a2
Figure A3. Uncorrected total evaporative resistances (Ret,raw), and according to Wang et al. [98], corrected total (Ret) and clothing (Recl) evaporative resistances of the tested clothing ensembles (m2Pa/W). For clothing combination descriptions, see Table 1, Table 2 and Table 3.
Figure A3. Uncorrected total evaporative resistances (Ret,raw), and according to Wang et al. [98], corrected total (Ret) and clothing (Recl) evaporative resistances of the tested clothing ensembles (m2Pa/W). For clothing combination descriptions, see Table 1, Table 2 and Table 3.
Biology 11 01813 g0a3

References

  1. Kahn, S.A.; Patel, J.H.; Lentz, C.W.; Bell, D.E. Firefighter burn injuries: Predictable patterns influenced by turnout gear. J. Burn Care Res. 2012, 33, 152–156. [Google Scholar] [CrossRef] [PubMed]
  2. Kim, D.-H.; Kim, S.; Lee, J.-Y. An empirical investigation of firefighting personal protective equipment and burn injuries in Korea. Ind. Health 2022, 60, 2–15. [Google Scholar] [CrossRef]
  3. Chou, C.; Tochihara, Y.; Ismail, M.S.; Lee, J.Y. Physiological strains of wearing aluminized and non-aluminized firefighters’ protective clothing during exercise in radiant heat. Ind. Health 2011, 29, 185–194. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Kim, S.; Kim, D.-H.; Lee, H.-H.; Lee, J.-Y. Frequency of firefighters’ heat-related illness and its association with removing personal protective equipment and working hours. Ind. Health 2019, 57, 370–380. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Taylor, N.A.S.; Lee, J.Y.; Kim, S.; Notley, S. Physiological interactions with personal-protective clothing, physically demanding work and global warming: An Asia-Pacific perspective. J. Therm. Biol. 2021, 97, 102858. [Google Scholar] [CrossRef] [PubMed]
  6. Dorman, L.E. The Effects of Protective Clothing and Its Properties on Energy Consumption during Different Activities. Doctoral’s Thesis, Loughborough University, Loughborough, UK, March 2007. [Google Scholar]
  7. Dorman, L.E.; Havenith, G. The effects of protective clothing on energy consumption during different activities. Eur. J. Appl. Physiol. 2009, 105, 463–470. [Google Scholar] [CrossRef] [Green Version]
  8. Teitlebaum, A.; Goldman, R.F. Increased energy cost with multiple clothing layers. J. Appl. Physiol. 1972, 32, 743–744. [Google Scholar] [CrossRef] [PubMed]
  9. Aljaroudi, A.M.; Bhattacharya, A.; Strauch, A.; Quinn, T.D.; Williams, W.J. Effect of cooling on static postural balance while wearing firefighter’s protective clothing in hot environment. Int. J. Occup. Saf. Ergon. 2022. online. [Google Scholar] [CrossRef] [PubMed]
  10. Son, S.Y.; Muraki, S.; Tochihara, Y. Exploring the appropriate test methods to examine the effects of firefighter personal protective equipment on mobility. Fash. Text. 2022, 9, 22. [Google Scholar] [CrossRef]
  11. Tochihara, Y.; Fujita, M.; Ogawa, T. Protective clothing—Related heat stress on firefighters in Japan. In Proceedings of the 11th International Conference on Environmental Ergonomics, Ystad, Sweden, 22–26 May 2005. [Google Scholar]
  12. Wang, S.; Park, J.; Wang, Y. Cross-cultural comparison of firefighters’ perception of mobility and occupational injury risks associated with personal protective equipment. Int. J. Occup. Saf. Ergon. 2021, 27, 664–672. [Google Scholar] [CrossRef] [PubMed]
  13. EN 469:2020; Protective Clothing for Firefighters—Performance Requirements for Protective Clothing for Firefighting Activities. European Committee for Standardization: Brussels, Belgium, 2020.
  14. ISO 21942:2019; Station Uniform for Firefighters. International Organization for Standardization: Geneva, Switzerland, 2019.
  15. ISO 11999 Series; PPE for Firefighters—Test Methods and Requirements for PPE Used by Firefighters Who Are at Risk of Exposure to High Levels of Heat and/or Flame While Fighting Fires Occurring in Structures. International Organization for Standardization: Geneva, Switzerland.
  16. ISO 11613:2017; Protective Clothing for Firefighter’s Who Are Engaged in Support Activities Associated with Structural Fire Fighting—Laboratory Test Methods and Performance. International Organization for Standardization: Geneva, Switzerland, 2017.
  17. ISO 15384:2018; Protective Clothing for Firefighters—Laboratory Test Methods and Performance Requirements for Wildland Firefighting Clothing. International Organization for Standardization: Geneva, Switzerland, 2018.
  18. ISO 16073 Series; Wildland Firefighting Personal Protective Equipment—Requirements and Test Methods. International Organization for Standardization: Geneva, Switzerland.
  19. ISO 18639 Series; PPE Ensembles for Firefighters Undertaking Specific Rescue Activities. International Organization for Standardization: Geneva, Switzerland.
  20. EN 16689:2017; Protective Clothing for Firefighters—Performance Requirements for Protective Clothing for Technical Rescue. European Committee for Standardization: Brussels, Belgium, 2017.
  21. ISO 17491 Series; Protective Clothing—Test Methods for Clothing Providing Protection against Chemicals. International Organization for Standardization: Geneva, Switzerland.
  22. ISO 16602:2007; Protective Clothing for Protection against Chemicals—Classification, Labelling and Performance Requirements. International Organization for Standardization: Geneva, Switzerland, 2007.
  23. Kingma, B.R.M.; Steenhoff, H.; Toftum, J.; Daanen, H.A.M.; Folkerts, M.A.; Gerrett, N.; Gao, C.; Kuklane, K.; Petersson, J.; Halder, A.; et al. ClimApp–integrating personal factors with weather forecasts for individualised warning and guidance on thermal stress. Int. J. Environ. Res. Public Health 2021, 18, 11317. [Google Scholar] [CrossRef] [PubMed]
  24. Petersson, J.; Kuklane, K.; Gao, C. Is there a need to integrate human thermal models with weather forecasts to predict thermal stress? Int. J. Environ. Res. Public Health 2019, 16, 4586. [Google Scholar] [CrossRef] [Green Version]
  25. Xu, X.; Rioux, T.P.; Gonzalez, J.; Hansen, E.O.; Castellani, J.W.; Santee, W.R.; Karis, A.J.; Potter, A.W. Development of a cold injury prevention tool: The cold weather ensemble decision aid (CoWEDA). In USARIEM Technical Report No. T19-06; USARIEM: Natick, MA, USA, March 2019. [Google Scholar]
  26. Xu, X.; Rioux, T.P.; Gonzalez, J.; Hansen, E.O.; Castellani, J.W.; Santee, W.R.; Karis, A.J.; Potter, A.W. A digital tool for prevention and management of cold weather injuries–Cold Weather Ensemble Decision Aid (CoWEDA). Int. J. Biometeorol. 2021, 65, 1415–1426. [Google Scholar] [CrossRef] [PubMed]
  27. Parsons, K. Human Thermal Environments, 3rd ed.; Taylor & Francis Group: Boca Raton, FL, USA, 2014. [Google Scholar]
  28. Taylor, N.A.S.; Machado-Moreira, C.A.; van den Heuvel, A.M.J.; Caldwell, J.N. Hands and feet: Physiological insulators, radiators and evaporators. Eur. J. Appl. Physiol. 2014, 114, 2037–2060. [Google Scholar] [CrossRef] [PubMed]
  29. Vanggaard, L.; Kuklane, K.; Holmer, I.; Smolander, J. Thermal responses to whole-body cooling in air with special reference to arteriovenous anastomoses in fingers. Clin. Physiol. Funct. Imaging 2012, 32, 463–469. [Google Scholar] [CrossRef] [PubMed]
  30. Smith, C.J.; Havenith, G. Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia. Eur. J. Appl. Physiol. 2011, 111, 1391–1404. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  31. Smith, C.J.; Havenith, G. Body mapping of sweating patterns in athletes: A sex comparison. Med. Sci. Sports. Exerc. 2012, 44, 2350–2361. [Google Scholar] [CrossRef] [Green Version]
  32. Taylor, N.A.S.; Machado-Moreira, C.A. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans. Extrem. Physiol. Med. 2013, 2, 4. [Google Scholar] [CrossRef] [Green Version]
  33. Wang, F.; Del Ferraro, S.; Molinaro, V.; Morrissey, M.; Rossi, R. Assessment of body mapping sportswear using a manikin operated in constant temperature mode and thermoregulatory model control mode. Int. J. Biometeorol. 2014, 58, 1673–1682. [Google Scholar] [CrossRef] [Green Version]
  34. Afanasieva, R.F. Hygienic Basis for Designing Cold Protective Clothing; Legkaja Industria: Moscow, Russia, 1977. (In Russian) [Google Scholar]
  35. Havenith, G.; Nilsson, H. Correction of clothing insulation for movement and wind effects, a meta-analysis. Eur. J. Appl. Physiol. 2004, 92, 636–640. [Google Scholar] [CrossRef]
  36. Lu, Y.; Wang, F.; Wan, X.; Song, G.; Zhang, C.; Shi, W. Clothing resultant thermal insulation determined on a movable thermal manikin. Part II: Effects of wind and body movement on local insulation. Int. J. Biometeorol. 2015, 59, 1487–1498. [Google Scholar] [CrossRef] [PubMed]
  37. Veselá, S.; Psikuta, A.; Frijns, A.J.H. Local clothing thermal properties of typical office ensembles under realistic static and dynamic conditions. Int. J. Biometeorol. 2018, 62, 2215–2229. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  38. Wang, F.; del Ferraro, S.; Lin, L.Y.; Sotto Mayor, T.; Ribeiro, M.; Gao, C.; Kuklane, K.; Holmér, I. Localised boundary air layer and clothing evaporative resistances for individual body segments. Ergonomics 2012, 55, 799–812. [Google Scholar] [CrossRef]
  39. Fojtlín, M.; Psikuta, A.; Fišer, J.; Toma, R.; Annaheim, S.; Jícha, M. Local clothing properties for thermo-physiological modelling: Comparison of methods and body positions. Build. Environ. 2019, 155, 376–388. [Google Scholar] [CrossRef]
  40. Havenith, G.; Fiala, D. Thermal indices and thermophysiological modeling for heat stress. In Comprehensive Physiology Wiley Online Library; John Wiley & Sons, Ltd.: Hoboken, NJ, USA, 2016; Volume 6, pp. 255–302. [Google Scholar] [CrossRef]
  41. Joshi, A.; Wang, F.; Kang, Z.; Yang, B.; Zhao, D. A three-dimensional thermoregulatory model for predicting human thermophysiological responses in various thermal environments. Build. Environ. 2022, 207, 108506. [Google Scholar] [CrossRef]
  42. Psikuta, A.; Koelblen, B.; Mert, E.; Fontana, P.; Annaheim, S. An integrated approach to develop, validate and operate thermo-physiological human simulator for the development of protective clothing. Ind. Health 2017, 55, 500–512. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  43. Psikuta, A.; Mert, E.; Annaheim, S.; Rossi, R.M. Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response. Int. J. Biometeorol. 2018, 62, 1121–1134. [Google Scholar] [CrossRef]
  44. Takahashi, Y.; Nomoto, A.; Yoda, S.; Hisayama, R.; Ogata, M.; Ozeki, Y.; Tanabe, S. Thermoregulation model JOS-3 with new open source code. Energy Build. 2021, 231, 110575. [Google Scholar] [CrossRef]
  45. Chen, Y.S.; Fan, J.; Qian, X.; Zhang, W. Effect of garment fit on thermal insulation and evaporative resistance. Text. Res. J. 2004, 74, 742–748. [Google Scholar] [CrossRef]
  46. Jussila, K.; Kekäläinen, M.; Simonen, L.; Mäkinen, H. Determining the optimum size combination of three-layered cold protective clothing in varying wind conditions and walking speeds: Thermal manikin and 3D body scanner study. J. Fashion Technol. Textile Eng. 2015, 3, 1–9. [Google Scholar] [CrossRef] [Green Version]
  47. ASTM F1291-16; Standard Test Method for Measuring the Thermal Insulation of Clothing Using a Heated Manikin. American Society of Testing and Materials International (ASTM): Philadelphia, PA, USA, 2016.
  48. EN 342:2017; Protective Clothing—Ensembles and Garments for Protection against Cold. European Committee for Standardization: Brussels, Belgium, 2017.
  49. ISO 15831:2004; Clothing-Physiological Effects-Measurement of Thermal Insulation by Means of a Thermal Manikin. International Organisation for Standardisation: Geneva, Switzerland, 2004.
  50. ISO 9920:2009; Ergonomics of the Thermal Environment—Estimation of the Thermal Insulation and Evaporative Resistance of a Clothing Ensemble. International Standards Organisation: Geneva, Switzerland, 2009.
  51. ASTM F2370-16; Standard Test Method for Measuring the Evaporative Resistance of Clothing Using a Sweating Manikin. American Society of Testing and Materials International (ASTM): Philadelphia, PA, USA, 2016.
  52. EN 17528: 2022; Clothing—Physiological Effects—Measurement of Water Vapour Resistance by Means of a SWEATING manikin. European Committee for Standardization: Brussels, Belgium, 2022.
  53. Wang, F.M. Measurements of clothing evaporative resistance using a sweating thermal manikin: An overview. Ind. Health 2017, 55, 473–484. [Google Scholar] [CrossRef] [Green Version]
  54. McCullough, E.A.; Jones, B.W.; Huck, J. A comprehensive data base for estimating clothing insulation (RP-411). ASHRAE Trans. 1985, 91, 29–47. [Google Scholar]
  55. McCullough, E.A.; Jones, B.W.; Tamura, T. A database for determining the evaporative resistance of clothing. ASHRAE Trans. 1989, 95, 316–328. [Google Scholar]
  56. Olesen, B.W.; Nielsen, R. Thermal insulation of clothing measured on a movable thermal manikin and on human subjects. In ECSC Programme Research Nr 7206/00/914; Technical University of Denmark: Copenhagen, Denmark, 1983. [Google Scholar]
  57. Al-ajmi, F.F.; Loveday, D.L.; Bedwell, K.H.; Havenith, G. Thermal insulation and clothing area factors of typical Arabian Gulf clothing ensembles for males and females: Measurements using thermal manikins. Appl. Ergon. 2008, 39, 407–414. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  58. Havenith, G.; Kuklane, K.; Fan, J.; Hodder, S.; Ouzzahra, Y.; Lundgren, K.; Au, Y.; Loveday, D. A Database of Static Clothing Thermal Insulation and Vapor Permeability Values of Non-Western Ensembles for Use in ASHRAE Standard 55, ISO 7730, and ISO 9920. ASHRAE Trans. 2015, 121, 197–215. [Google Scholar]
  59. Wang, F.; Peng, H.; Shi, W. The relationship between air layers and evaporative resistance of male Chinese ethnic clothing. Appl. Ergon. 2016, 56, 194–202. [Google Scholar] [CrossRef] [PubMed]
  60. Havenith, G.; Bröde, P.; den Hartog, E.; Kuklane, K.; Holmer, I.; Rossi, R.M.; Richards, M.; Farnworth, B.; Wang, X. Evaporative cooling: Effective latent heat of evaporation in relation to evaporation distance from the skin. J. Appl. Physiol. 2013, 114, 778–785. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  61. Joshi, A.; Psikuta, A.; Bueno, M.A.; Annaheim, S.; Rossi, R.M. Effect of movement on convection and ventilation in a skin-clothing- environment system. Int. J. Therm. Sci. 2021, 166, 106965. [Google Scholar] [CrossRef]
  62. Lu, Y.; Wang, F.; Wan, X.; Song, G.; Shi, W.; Zhang, C. Clothing resultant thermal insulation determined on a movable thermal manikin. Part I: Effects of wind and body movement on total insulation. Int. J. Biometeorol. 2015, 59, 1475–1486. [Google Scholar] [CrossRef]
  63. Smallcombe, J.; Hodder, S.; Loveday, D.; Kuklane, K.; Mlynarczyk, M.; Halder, A.; Petersson, J.; Havenith, G. Updated Database of Clothing Thermal Insulation and Vapor Permeability Values of Western Ensembles for Use in ASHRAE Standard 55, ISO 7730 and ISO 9920; Results of ASHRAE RP-1760. ASHRAE Trans. 2021, 127, 773–799. [Google Scholar]
  64. Rioux, T.P.; Karis, A.J.; Moore, B.A.; Xu, X. Biophysical evaluation of individual component levels and selected configurations of the United States Marine Corps cold-weather clothing ensemble. 01760. In Technical Report, T18-01; AD1046520; U.S. Army Research Institute of Environmental Medicine: Natick, MA, USA, 2018. [Google Scholar]
  65. Rioux, T.; Gonzalez, J.A.; Karis, A.; Potter, A.W.; Xu, X. Biophysical properties of five cold weather clothing systems and the predicted regional properties of ensembles. In USARIEM Technical Report T21-03; AD1115339; USARIEM: Natick, MA, USA, 2020. [Google Scholar]
  66. Šitvjenkins, I. Enhancement of Combat Individual Protection System. Doctoral’s Thesis, Riga Technical University, Riga, Latvia, 2014. [Google Scholar]
  67. Šitvjenkins, I.; Kuklane, K.; Vilumsone, A.; Abele, I. Development of the combat sleeping bag system of the Latvian National Armed Forces. In Proceedings of the 6th European Conference of Protective Clothing, Bruges, Belgium, 14–16 May 2014. [Google Scholar]
  68. Xu, X.; Rioux, T.P.; Pomerantz, N.; Tew, S. Effects of fabric on thermal and evaporative resistances of chemical protective ensembles: Measurement and quantification. Measurement 2019, 136, 248–255. [Google Scholar] [CrossRef]
  69. Xu, X.; Rioux, T.P.; Pomerantz, N.; Tew, S.; Blanchard, L.A. Heat strain in chemical protective ensembles: Effects of fabric thermal properties. J. Therm. Biol. 2019, 86, 102435. [Google Scholar] [CrossRef] [PubMed]
  70. Kuklane, K.; Toma, R. Validation of ISO 9920 clothing item insulation summation method based on an ambulance personnel clothing system. Ind. Health 2021, 59, 27–33. [Google Scholar] [CrossRef] [PubMed]
  71. Kuklane, K.; Toma, R. Common clothing area factor estimation equations are inaccurate for highly insulating (Icl > 2 clo) and non-western loose-fitting clothing ensembles. Ind. Health 2021, 59, 107–116. [Google Scholar] [CrossRef]
  72. Anttonen, H.; Niskanen, J.; Meinander, H.; Bartels, V.; Kuklane, K.; Reinertsen, R.E.; Varieras, S.; Sołtyński, K. Thermal manikin measurements- exact or not? Int. J. Occup. Saf. Ergon. 2004, 10, 291–300. [Google Scholar] [CrossRef]
  73. Gavhed, D.; Kuklane, K.; Holmér, I. The influence of the number of thermal layers on the clothing insulation of a cold-protective ensemble. In Proceedings of the NOKOBETEF 6 and 1st European Conference on Protective clothing, Stockholm, Sweden, 7–10 May 2000. [Google Scholar]
  74. Gavhed, D.; Kuklane, K.; Holmér, I. Thermal insulation of multi-layer clothing ensembles measured on a thermal manikin and estimated by six individuals using the summation method in ISO 9920. In Proceedings of the NOKOBETEF 6 and 1st European Conference on Protective clothing, Stockholm, Sweden, 7–10 May 2000. [Google Scholar]
  75. Meinander, H.; Anttonen, H.; Bartels, V.; Holmér, I.; Reinertsen, R.E.; Sołtyński, K.; Varieras, S. Thermal insulation measurements of cold protective clothing using thermal manikins. In SUBZERO Project, Final Report (Report No. 4); Fibre Materials Science, Tampere University of Technology: Tampere, Finland, 2003. [Google Scholar]
  76. Oliveira, A.V.M.; Gaspar, A.R.; Quintela, D.A. Measurements of clothing insulation with a thermal manikin operating under the thermal comfort regulation mode. Comparative analysis of the calculation methods. Eur. J. Appl. Physiol. 2008, 104, 679–688. [Google Scholar] [CrossRef]
  77. Oliveira, A.V.M.; Gaspar, A.R.; Quintela, D.A. Dynamic clothing insulation. Measurements with a thermal manikin operating under the thermal comfort regulation mode. Appl. Ergon. 2011, 42, 890–899. [Google Scholar] [CrossRef]
  78. Kuklane, K.; Toma, R.; Lucas, R.A. Insulation and evaporative resistance of clothing for sugarcane harvesters and chemical sprayers, and their application in PHS model-based exposure predictions. Int. J. Environ. Res. Public Health 2020, 17, 3074. [Google Scholar] [CrossRef]
  79. Toma, R.; Kuklane, K.; Fojtlín, M.; Fišer, J.; Jícha, M. Using a thermal manikin to determine evaporative resistance and thermal insulation-a comparison of methods. J. Ind. Text. 2021, 50, 1493–1515. [Google Scholar] [CrossRef]
  80. ISO 11079:2007; Ergonomics of the Thermal Environment—Determination and Interpretation of Cold Stress when Using Required Clothing Insulation (IREQ) and Local Cooling Effects. International Organisation for Standardisation: Geneva, Switzerland, 2007.
  81. ISO 7933:2004; Ergonomics of the Thermal Environment—Analytical Determination and Interpretation of Heat Stress Using Calculation of the Predicted Heat Strain. International Organisation for Standardisation: Geneva, Switzerland, 2004.
  82. ISO 7730:2005; Ergonomics of the Thermal Environment—Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria. International Organisation for Standardisation: Geneva, Switzerland, 2005.
  83. Holmér, I. Assessment of cold stress in terms of required clothing insulation-IREQ. Int. J. Ind. Ergon. 1988, 3, 159–166. [Google Scholar] [CrossRef]
  84. Malchaire, J.; Kampmann, B.; Mehnert, P.; Gebhardt, H.; Piette, A.; Havenith, G.; Holmér, I.; Parsons, K.; Alfano, G.; Griefahn, B. Assessment of the risk of heat disorders encountered during work in hot conditions. Int. Arch. Occup. Environ. Health 2002, 75, 153–162. [Google Scholar] [CrossRef] [PubMed]
  85. Malchaire, J.; Piette, A.; Kampmann, B.; Mehnert, P.; Gebhardt, H.; Havenith, G.; den Hartog, E.; Holmer, I.; Parsons, K.; Alfano, G.; et al. Development and validation of the predicted heat strain model. Ann. Occup. Hyg. 2001, 45, 123–135. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  86. Hänel, S.E. A joint Nordic project to develop an improved thermal manikin for modeling and measuring human heat exchange. In The Medical and Biophysical Aspects on Protective Clothing; Centre de Recherches du Service de Santk des Armks: Lyon, France, 1983; pp. 280–282. [Google Scholar]
  87. Kuklane, K.; Heidmets, S.; Johansson, T. Improving thermal comfort in an orthopaedic aid: Better Boston Brace for scoliosis patients. In Proceedings of the 6th International Meeting on Manikins and Modelling (6I3M), Hong Kong, China, 16–18 October 2006; pp. 343–351. [Google Scholar]
  88. Kuklane, K.; Dejke, V. Testing sleeping bags according to EN 13537:2002: Details that make the difference. Int. J. Occup. Saf. Ergon. 2010, 16, 199–216. [Google Scholar] [CrossRef] [PubMed]
  89. Wang, F.; Havenith, G.; Mayor, T.S.; Kuklane, K.; Leonard, J.; Zwolinska, M.; Hodder, S.; Wong, C.; Kishino, J.; Dai, X. Clothing real evaporative resistance determined by means of a sweating thermal manikin: A new round-robin study. In Proceedings of the Ambience 14&10i3m: Scientific Conference for Smart and Functional Textiles, Well-Being, Thermal Comfort in Clothing, Design, Thermal Manikins and Modeling, Tampere, Finland, 7–9 September 2014. [Google Scholar]
  90. Psikuta, A.; Kuklane, K.; Bogdan, A.; Havenith, G.; Annaheim, S.; Rossi, R.M. Opportunities and constraints of presently used thermal manikins for thermo-physiological simulation of the human body. Int. J. Biometeorol. 2016, 60, 435–446. [Google Scholar] [CrossRef] [Green Version]
  91. Holmér, I.; Kuklane, K.; Gao, C. Test of firefighter’s turnout gear in hot and humid air exposure. Int. J. Occup. Saf. Ergon. 2006, 12, 297–305. [Google Scholar] [CrossRef]
  92. Gao, C.; Kuklane, K.; Holmér, I. Cooling vests with phase change material packs: The effects of temperature gradient, mass, and covering area. Ergonomics 2010, 53, 716–723. [Google Scholar] [CrossRef]
  93. Smolander, J.; Kuklane, K.; Gavhed, D.; Nilsson, H.; Holmér, I. Effectiveness of a light-weight ice-vest for cooling while wearing fire fighter’s protective clothing in the heat. Int. J. Occup. Saf. Ergon. 2004, 10, 111–117. [Google Scholar] [CrossRef]
  94. Huang, J. Calculation of thermal insulation of clothing from mannequin test. Meas. Tech. 2008, 51, 428–435. [Google Scholar] [CrossRef]
  95. Kuklane, K.; Gao, C.; Holmér, I.; Giedraityte, L.; Bröde, P.; Candas, V.; den Hartog, E.; Meinander, H.; Richards, M.; Havenith, G. Calculation of clothing insulation by serial and parallel methods: Effects on clothing choice by IREQ and thermal responses in the cold. Int. J. Occup. Saf. Ergon. 2007, 13, 103–116. [Google Scholar] [CrossRef] [Green Version]
  96. Kuklane, K.; Gao, C.; Wang, F.; Holmér, I. Parallel and serial methods of calculating thermal insulation in European manikin standards. Int. J. Occup. Saf. Ergon. 2012, 18, 171–179. [Google Scholar] [CrossRef]
  97. Lee, J.; Ko, E.; Lee, H.; Kim, J.; Choi, J. Validation of clothing insulation estimated by global and serial methods. Int. J. Cloth. Sci. Technol. 2011, 23, 184–198. [Google Scholar] [CrossRef]
  98. Wang, F.; Kuklane, K.; Gao, C.; Holmér, I. Development and validity of a universal empirical equation to predict skin surface temperature on thermal manikins. J. Therm. Biol. 2010, 35, 197–203. [Google Scholar] [CrossRef]
  99. Lu, Y.; Wang, F.; Peng, H. Effect of two sweating simulation methods on clothing evaporative resistance in a so-called isothermal condition. Int. J. Biometeorol. 2016, 60, 1041–1049. [Google Scholar] [CrossRef] [PubMed]
  100. Lu, Y.; Wang, F.; Peng, H.; Shi, W.; Song, G. Effect of sweating set rate on clothing real evaporative resistance determined on a sweating thermal manikin in a so-called isothermal condition (Tmanikin = Ta = Tr). Int. J. Biometeorol. 2016, 60, 481–488. [Google Scholar] [CrossRef] [PubMed]
  101. Wang, F.; Lai, D.; Shi, W.; Fu, M. Effects of fabric thickness and material on apparent ‘wet’ conductive thermal resistance of knitted fabric ‘skin’ on sweating manikins. J. Therm. Biol. 2017, 70, 69–76. [Google Scholar] [CrossRef]
  102. Ueno, S.; Sawada, S. Correction of the evaporative resistance of clothing by the temperature of skin fabric on a sweating and walking thermal manikin. Text. Res. J. 2012, 82, 1143–1156. [Google Scholar] [CrossRef]
  103. Anttonen, H.; Hellsten, M.; Bartels, V.; Kuklane, K.; Niskanen, J. Report of the manikin measurements with analysis of the test results. In SUBZERO Project, D2; Oulu Regional Institute of Occupational Health: Oulu, Finland, 2002. [Google Scholar]
  104. Deaton, A.S.; Watson, K.; DenHartog, E.A.; Barker, R.L. Effectiveness of using a thermal sweating manikin coupled with a thermoregulation model to predict human physiological response to different firefighter turnout suits. In Performance of Protective Clothing and Equipment; Innovative Solutions to Evolving Challenges; Lehtonen, K., Shiels, B.P., Ormond, R.B., Eds.; ASTM International: West Conshohocken, PA, USA, 2020; Volume 11, pp. 222–236. [Google Scholar] [CrossRef]
  105. DenHartog, E.A.; Fang, X.; Deaton, A.S. Effects of total heat loss versus evaporative resistance of firefighter garments in a physiological heat strain trial. In Performance of Protective Clothing and Equipment; Innovative Solutions to Evolving Challenges; Lehtonen, K., Shiels, B.P., Ormond, R.B., Eds.; ASTM International: West Conshohocken, PA, USA, 2020; Volume 11, pp. 204–221. [Google Scholar] [CrossRef]
  106. Lee, J.; Choi, J. Estimation of regional body surface area covered by clothing. J. Hum. Environ. Syst. 2009, 12, 35–45. [Google Scholar] [CrossRef] [Green Version]
  107. Mert, E.; Psikuta, A.; Bueno, M.-A.; Rossi, R.M. The effect of body postures on the distribution of air gap thickness and contact area. Int. J. Biometeorol. 2017, 61, 363–375. [Google Scholar] [CrossRef]
  108. Ciuha, U.; Valenčič, T.; Mekjavic, I.B. Cooling efficiency of vests with different cooling concepts over 8-hour trials. Ergonomics 2021, 64, 625–639. [Google Scholar] [CrossRef]
  109. Krause, R.; Kuklane, K.; Kemmeren, M.; Gries, T. Europäische nutzerumfrage zu smarter persönliche schutzausrüstung für feuerwehreinsatzkräfte. Crisis Prev. 2021, 3, 34–39. (In German) [Google Scholar]
  110. Lee, J.-Y.; Park, J.; Park, H.; Coca, A.; Kim, J.-H.; Taylor, N.A.S.; Son, S.-Y.; Tochihara, Y. What do firefighters desire from the next generation of personal protective equipment? Outcomes from an international survey. Ind. Health 2015, 53, 434–444. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  111. Havenith, G.; Heus, R. A test battery related to ergonomics of protective clothing. Appl. Ergon. 2004, 35, 3–20. [Google Scholar] [CrossRef] [PubMed]
  112. ISO/TS 20141:2022; Personal Safety—Personal Protective Equipment—Guidelines on Compatibility Testing of PPE. International Standards Organisation: Geneva, Switzerland, 2022.
Figure 1. Separate relationships between measured and summed basic clothing insulation (Icl, clo) for (a) operational uniform and (b) incident clothing ensembles. Icl (sum, ISO 9920) represents summation according to ISO 9920, and Icl (sum, new) modified the summation for these datasets.
Figure 1. Separate relationships between measured and summed basic clothing insulation (Icl, clo) for (a) operational uniform and (b) incident clothing ensembles. Icl (sum, ISO 9920) represents summation according to ISO 9920, and Icl (sum, new) modified the summation for these datasets.
Biology 11 01813 g001
Figure 2. Relationship between the measured and the estimated clothing area factors for the firefighter clothing system by various available equations. fcl (or fcl)—clothing area factor; IT—total clothing insulation; Icl—basic clothing insulation.
Figure 2. Relationship between the measured and the estimated clothing area factors for the firefighter clothing system by various available equations. fcl (or fcl)—clothing area factor; IT—total clothing insulation; Icl—basic clothing insulation.
Biology 11 01813 g002
Table 1. Clothing item specifications and their total insulation (IT), clothing area factor (fcl) and basic clothing insulation (Iclu).
Table 1. Clothing item specifications and their total insulation (IT), clothing area factor (fcl) and basic clothing insulation (Iclu).
Nr.Item and Their Variation DescriptionPhotoBrand, ModelSize, VersionWeight
(Grams)
Materials (Notes)IT
m2K/W
fcl
n.d.
Iclu
m2K/W
ALNude manikin
(air layer insulation—Ia)
Biology 11 01813 i001 0.0991.000.000
1SocksBiology 11 01813 i002Groenendijk, Brandweer Nederland43–4562.2 0.1071.010.009
2Low safety shoesBiology 11 01813 i003Neskrid, Crow S3 low45, W111554.1PU sole, leather uppers, fabric padding0.1071.020.010
3High safety shoesBiology 11 01813 i004Haix, Airpower XR1452153.4PU sole, leather uppers, fabric padding0.1091.060.015
4Firefighter bootsBiology 11 01813 i005Haix, Fire flash gamma44, W122939.3PU sole, leather uppers, fabric padding, Gore-Crosstech0.1131.070.021
5Baseball capBiology 11 01813 i006Groenendijk, Brandweer Nederlandone size91.350% cotton
48% polyester
2% elastane
0.1031.010.005
6BeanieBiology 11 01813 i007Groenendijk, Brandweer Nederlandone size49.580% Wool
20% Acrylic
0.1041.000.005
7Balaclava/fire hoodBiology 11 01813 i008Viking Life Saving Equipment A/S, Type 1one size119.4100% Aramid0.1071.010.009
8Boxershorts (underwear)Biology 11 01813 i009GS SportXL69.495% Cotton
5% Elastane
0.1061.010.008
9T-shirt (underwear)Biology 11 01813 i010Narkonteks, Brandweer NederlandL, regular182.160% Mode Acrylic
40% Cotton, Ribana, 190 g/m2
0.1241.030.027
10Belt (stretch-heavy)Biology 11 01813 i011Groenendijk105106.2 0.1021.000.003
11Polo shirt, short sleevesBiology 11 01813 i012Narkonteks, Brandweer NederlandL, regular345.860% Mode Acrylic
40% Cotton, Pique, 200 g/m2
0.1311.080.040
12Polo shirt, long sleevesBiology 11 01813 i013Narkonteks, Brandweer NederlandL, regular427.260% Mode Acrylic
40% Cotton, Pique, 200 g/m2
0.1401.090.049
13(Polo)sweater (400 gr)Biology 11 01813 i014Narkonteks, Brandweer NederlandL, regular842.150% Mode Acrylic
50% Cotton, three thread fleece, 400 g/m2
0.1481.140.061
14Softshell (zip open at neck)Biology 11 01813 i015SIOEN, Brandweer NederlandL, regular787.2 0.1451.110.056
14ASoftshell (fully zipped)Biology 11 01813 i016SIOEN, Brandweer NederlandL, regular787.2 0.1461.140.059
15Working trousersBiology 11 01813 i017SIOEN, Brandweer Nederland52, regular697.742% modacrylic, 29% cotton
19% polyamide FR, 5% aramid
4% elastolefin, 1% antistatic (AST) yarn
0.1361.120.047
16Safety gloves (cut resistant) for technical rescueBiology 11 01813 i018GUIDE, 3131182.7 0.1021.010.004
17Safety gloves (for structural firefighting)Biology 11 01813 i019Eska, Helios E10366.2 0.1021.030.005
18Technical rescue jacketBiology 11 01813 i020SIOEN, 233 Proviz/ASL, regular1431.7OL: 54% Nomex®, 28% polyester
17% viscose FR, 1% AST
Lining: 100% aramid laminated with bi-component ePTFE membrane + AST
0.1621.170.077
19Firefighter top layer jacket (to be used on top of item 18)Biology 11 01813 i021SIOEN, TL TWIN/ASL, regular1312.0OL: 100% aramid + AST
Lining: 50% aramid
50% viscose FR
0.1711.170.087
21Firefighter jacket (corresponds to EN 469)Biology 11 01813 i022SIOEN, 830 Twin/ASL, regular1793.8OL: 100% aramid + AST
ML: 100% aramid laminated with bi-component ePTFE membrane
Lining: 100% aramid + AST
0.1771.230.097
22Firefighter trousers, standard model (corresponds to EN 469) Biology 11 01813 i023SIOENL, regular1712.5OL: 100% aramid + AST
ML: 100% aramid laminated with bi-component ePTFE membrane
Lining: 100% aramid + AST
0.1681.320.093
23Firefighter trousers, dungarees (corresponds to EN 469) Biology 11 01813 i024SIOENL, regular1795.3OL: 100% aramid + AST
ML: 100% aramid laminated with bi-component ePTFE membrane
Lining: 100% aramid + AST
0.1671.360.095
24Firefighter coverall (corresponds to EN 469)Biology 11 01813 i025SIOENL, regular2883.2OL: 100% aramid + AST
ML: 100% aramid laminated with bi-component ePTFE membrane
Lining: 100% aramid + AST
0.3031.470.236
25Firefighter helmetBiology 11 01813 i026Dräger, HPS 7000 H150–601621.3 0.1031.070.011
26Face and neck cover (hollanddoek, connected to helmet (item 25), closed in front)Biology 11 01813 i027Drägerone size161.3 0.1071.120.018
26AFace and neck cover (hollanddoek, connected to helmet (item 25), open in front, fixed at back side)Biology 11 01813 i028Drägerone size161.3 0.1051.100.016
27Technical rescue helmetBiology 11 01813 i029MSA Gallet, F2 X-trem52–64 cm830.1 0.1021.050.008
28Self-Contained Breathing Apparatus (SCBA, bottles only)Biology 11 01813 i030Interspiro,
V-RWS
XXL11,469.9Composite with 2 bottles.0.1041.150.018
29High visibility vestBiology 11 01813 i031Coprit, V-RWSXXL166.4100% polyester0.1171.080.026
30Winter jacket (doorwerkjas) with thermal liningBiology 11 01813 i032SIOEN, Brandweer NederlandL, regular1594.3OL and lining: 100% Polyester
Membrane: 100% Polyurethane
Thermal liner: 100% Polyester insulation between 100% polyamide layers
0.1631.190.080
30AWinter jacket (doorwerkjas) without thermal lining (outer shell only)Biology 11 01813 i033SIOEN, Brandweer NederlandL, regular1253.1OL and lining: 100% Polyester
Membrane: 100% Polyurethane
0.1511.160.066
30BWinter jacket (doorwerkjas) without thermal lining (outer shell only) and with hood half way (it was not allowed to cut)Biology 11 01813 i034SIOEN, Brandweer NederlandL, regular1353.0OL and lining: 100% Polyester
Membrane: 100% Polyurethane
0.1611.190.078
30CThermal liner of the winter jacket aloneBiology 11 01813 i035SIOEN, Brandweer NederlandL, regular341.2100% Polyester insulation between 100% polyamide layers0.1561.130.068
31SCBA system (items 26, 28 and facemask from Dräger fitting the helmet)Biology 11 01813 i036Dräger, FPS 7000/InterspiroM, HMC755.0Rubber/plastic glass0.1131.260.034
31AFace maskBiology 11 01813 i037Interspiro 1228.7Rubber/plastic glass0.1001.070.008
31BSCBA system (items 28 and 31A)Biology 11 01813 i038Interspiro 12,698.6Rubber/plastic glass, composite0.1061.220.025
Table 2. Clothing ensembles and their properties * (for images of the clothing ensembles see Table 3).
Table 2. Clothing ensembles and their properties * (for images of the clothing ensembles see Table 3).
CodeItems in the Ensemble (See Table 1)IT
m2K/W
fcl
n.d.
Icl
m2K/W
Icl
clo
Ret,raw
m2Pa/W
Ret
m2Pa/W
Recl
m2Pa/W
im
n.d.
im,cl
n.d.
ALNude manikin
(air layer insulation—Ia)
0.0991.000.0000.00
SKManikin’s textile skin (cotton)0.1311.030.0400.2611.58.0
C11, 2, 8, 9, 10, 11, 150.1871.190.1040.6722.318.712.00.610.52
C1A1, 2, 8, 9, 10, 11, 14, 150.2361.240.1571.0135.231.525.00.450.37
C1B1, 2, 8, 9, 10, 11, 14, 15
The same as C1A but with softshell zip fully closed
0.2451.240.1661.07
C21, 2, 8, 9, 10, 12, 150.2051.190.1220.7925.722.015.40.560.48
C2A1, 2, 8, 9, 10, 12, 14, 150.2371.260.1591.0332.929.323.00.490.42
C2B1, 2, 8, 9, 10, 12, 14, 15, 160.2411.270.1631.05
C2C1, 3, 8, 9, 10, 12, 14, 15, 290.2551.290.1791.15
C2D1, 3, 6, 8, 9, 10, 12, 15, 30A0.2731.320.1981.2845.541.835.70.400.33
C2E1, 3, 6, 8, 9, 10, 12, 15, 30B0.2821.330.2081.34
C2F1, 3, 6, 8, 9, 10, 12, 15, 300.3001.340.2261.46
C2G1, 3, 6, 8, 9, 10, 12, 15, 16, 30
The same as C2F but with technical rescue gloves (Table 1, item 16)
0.3071.340.2341.5148.044.338.30.420.37
C31, 2, 8, 9, 10, 13, 150.2271.260.1480.95
C3A1, 3, 6, 8, 9, 10, 13, 15, 160.2341.270.1561.01
C3B1, 3, 6, 8, 9, 10, 13, 14, 15, 160.2711.290.1941.2541.938.232.00.430.36
C41, 4, 8, 9, 10, 12, 15, 17, 18, 19, 22, 31 (consisting of 26 (hollanddoek fixed to 25), 28 and facemask similar to 31A but fixed to helmet)0.4771.680.4182.6985.381.476.70.350.33
C51, 4, 8, 9, 10, 12, 15, 17, 24, 26 (as part of 25)0.4361.600.3742.41
C61, 4, 8, 9, 10, 12, 15, 17, 21, 22, 26 (as part of 25)0.4561.580.3932.5474.470.665.60.390.36
C6A1, 4, 8, 9, 10, 12, 15, 17, 21, 22, 31 (consisting of 26 (hollanddoek fixed to 25), 28 and facemask similar to 31A but fixed to helmet)0.4651.650.4052.6287.483.678.80.340.31
C6B1, 4, 7, 8, 9, 10, 12, 15, 17, 21, 22, 25, 28, 31A0.4761.660.4172.69
C6C1, 4, 8, 9, 10, 12, 15, 17, 21, 23, 31 (consisting of 26 (hollanddoek fixed to 25), 28 and facemask similar to 31A but fixed to helmet)0.4571.650.3972.56
C71, 4, 8, 9, 10, 12, 15, 17, 18, 19, 22, 26 (hollanddoek fixed to 25)0.4661.570.4032.60
C81, 4, 8, 9, 10, 12, 15, 17, 18, 22, 26A (hollanddoek front open fixed to 25)0.4251.520.3612.3376.472.667.40.360.32
C91, 4, 8, 9, 10, 15, 16, 18, 22, 270.3721.490.3051.97
C9A1, 4, 8, 9, 10, 12, 15, 16, 18, 22, 270.3901.490.3242.0963.259.454.00.400.36
C9B1, 4, 8, 9, 10, 12, 15, 17, 18, 22, 270.4071.490.3412.20
* IT—total clothing insulation; fcl—clothing area factor; Icl—basic clothing insulation; Ret,raw—uncorrected total evaporative resistance; Ret—corrected total evaporative resistance; Recl—corrected clothing evaporative resistance; im—moisture permeability index; im,cl—clothing moisture permeability index; for details see Section 2.6.
Table 3. Images of the tested clothing ensembles (for properties and composition, see Table 2).
Table 3. Images of the tested clothing ensembles (for properties and composition, see Table 2).
ALSK
Biology 11 01813 i039Biology 11 01813 i040
C1C1AC2C2A
Biology 11 01813 i041Biology 11 01813 i042Biology 11 01813 i043Biology 11 01813 i044
C2BC2CC2DC2E
Biology 11 01813 i045Biology 11 01813 i046Biology 11 01813 i047Biology 11 01813 i048
C2FC3C3AC3B
Biology 11 01813 i049Biology 11 01813 i050Biology 11 01813 i051Biology 11 01813 i052
C4C5C6C6A
Biology 11 01813 i053Biology 11 01813 i054Biology 11 01813 i055Biology 11 01813 i056
C6BC6CC7C8
Biology 11 01813 i057Biology 11 01813 i058Biology 11 01813 i059Biology 11 01813 i060
C9C9AC9B
Biology 11 01813 i061Biology 11 01813 i062Biology 11 01813 i063
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kuklane, K.; Eggeling, J.; Kemmeren, M.; Heus, R. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813. https://doi.org/10.3390/biology11121813

AMA Style

Kuklane K, Eggeling J, Kemmeren M, Heus R. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology. 2022; 11(12):1813. https://doi.org/10.3390/biology11121813

Chicago/Turabian Style

Kuklane, Kalev, Jakob Eggeling, Maurice Kemmeren, and Ronald Heus. 2022. "A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles" Biology 11, no. 12: 1813. https://doi.org/10.3390/biology11121813

APA Style

Kuklane, K., Eggeling, J., Kemmeren, M., & Heus, R. (2022). A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology, 11(12), 1813. https://doi.org/10.3390/biology11121813

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop