Next Article in Journal
Epigenetic Dysregulation of Trophoblastic Gene Expression in Gestational Trophoblastic Disease
Next Article in Special Issue
Long-Term Reduction of Bacterial Adhesion on Polyurethane by an Ultra-Thin Surface Modifier
Previous Article in Journal
The Immune Regulatory Role of Protein Kinase CK2 and Its Implications for Treatment of Cancer
Previous Article in Special Issue
Experimental Bioactive Glass-Containing Composites and Commercial Restorative Materials: Anti-Demineralizing Protection of Dentin
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants

by
Katja Andrina Kravanja
and
Matjaž Finšgar
*
Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova 17, 2000 Maribor, Slovenia
*
Author to whom correspondence should be addressed.
Biomedicines 2021, 9(12), 1936; https://doi.org/10.3390/biomedicines9121936
Submission received: 22 November 2021 / Revised: 13 December 2021 / Accepted: 15 December 2021 / Published: 17 December 2021
(This article belongs to the Special Issue New Techniques and Materials for Biomedical Applications)

Abstract

:
The development of bioactive coatings for orthopedic implants has been of great interest in recent years in order to achieve both early- and long-term osseointegration. Numerous bioactive materials have been investigated for this purpose, along with loading coatings with therapeutic agents (active compounds) that are released into the surrounding media in a controlled manner after surgery. This review initially focuses on the importance and usefulness of characterization techniques for bioactive coatings, allowing the detailed evaluation of coating properties and further improvements. Various advanced analytical techniques that have been used to characterize the structure, interactions, and morphology of the designed bioactive coatings are comprehensively described by means of time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM), 3D tomography, quartz crystal microbalance (QCM), coating adhesion, and contact angle (CA) measurements. Secondly, the design of controlled-release systems, the determination of drug release kinetics, and recent advances in drug release from bioactive coatings are addressed as the evaluation thereof is crucial for improving the synthesis parameters in designing optimal bioactive coatings.

1. Introduction

The demand for orthopedic surgery is increasing with the aging of the population. Joint replacement due to osteoarthritis is one of the most commonly performed orthopedic procedures. Therefore, the development of suitable implants is crucial, especially due to frequent revision surgeries, which occur mainly due to aseptic loosening [1]. To ensure the adequate durability of an implant, the criteria for material selection must be met in terms of the mechanical properties (the modulus of elasticity, strength, ductility, etc.), surface roughness, corrosion resistance, and biocompatibility. Generally, implant materials consist of various polymers, ceramics, and metals (e.g., pure titanium, titanium alloys, stainless steel, and cobalt-chromium alloys) that possess adequate mechanical and corrosion-resistant properties, but which often do not exhibit the biological response that is key to successful osseointegration [1,2,3].
Osseointegration is defined as the direct structural and functional connection between the living bone and the surface of the load-bearing implant, which results from numerous cellular and extracellular biological processes [4]. Cell adhesion can be strongly influenced by the topographic features of the implant (hydrophilicity, roughness) [5,6,7]. Drug-eluting porous implants and biodegradable implants that degrade over time and are replaced by healthy body tissue have also attracted considerable interest [8,9]. However, another relatively simple approach leading to successful osseointegration and long-term stability can be achieved by coating implants with bioactive coatings that eliminate implant biological inertness and promote tissue–implant bonding at the interface [10,11,12,13,14,15].
Ideal bioactive coatings have the following properties: osteoinductivity, osteoconductivity [4], biocompatibility, an anti-inflammatory response [16], antimicrobial activity [17,18], corrosion mitigation, as well as suitable mechanical properties [19]. They can be composed of bioactive materials; various polymers [20], hydroxyapatite (HA) [21], calcium phosphate (CaP), titania nanotubes (TNTs) [22], carbon nanomaterials [23], etc.; they can also contain active substances that are released from their structure into the local environment [20]. Accordingly, the incorporation of anti-inflammatory drugs, such as nonsteroidal anti-inflammatory drugs (NSAIDs), can greatly reduce postoperative inflammation, as well as improving the osteointegration of the implant by promoting osteoblast proliferation [24]. Furthermore, the inclusion of antibiotics in implant coatings is recommended, as improper surgery and postoperative contamination from nearby tissues or hematogenous sources often lead to infections [25]. The addition of growth factors and osteoclast inhibitors has a positive effect on the quality of newly formed bone tissue [26,27,28,29,30], whereas the addition of anticoagulants may reduce the risk of clot formation and improve the blood compatibility of the biomaterials without affecting cell proliferation [31]. A number of factors influence the kinetics of the drug release, with the selection of an appropriate coating material and coating deposition technique (e.g., 3D printing, electrospinning [32], electrophoretic deposition [30], dip coating [33], drop casting [34], sol-gel deposition [35], biomimetic deposition [36], layer-by-layer deposition (LbL) [15], anodization [37], etc.) being particularly important, as they dictate the final shape of the drug delivery system, thus allowing a controlled and prolonged release for up to several months [38,39,40,41,42]. The novelty of a bioactive coating can only be appreciated by characterizing it, particularly under the chosen synthesis conditions.
In this regard, the use of time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and Fourier transform infrared spectroscopy (FTIR) is presented below, as these methods can characterize bioactive coatings and provide insight into their chemical composition [43,44,45,46,47,48]. The employment of atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and 3D-tomography is also reviewed as they can provide visual information regarding the topography and morphology of such coatings [49,50,51]. Moreover, the use of a quartz crystal microbalance (QCM) is presented as this technique provides information regarding the material adsorption/desorption [52]. In addition, the use of adhesion tests is presented, which are performed to determine whether a coating attaches sufficiently to the substrate, and lastly, contact angle (CA) measurements are described as they play an important role in determining the hydrophobic or hydrophilic character of the material surface [53,54].
The aim of this review is to comprehensively discuss and critically evaluate recent advances in two segments of the characterization of bioactive coatings: (1) characterization techniques used to obtain interaction and morphology data, and (2) in vitro drug release testing, which is essential for optimizing controlled release formulations to achieve the desired release kinetics.

2. Interaction and Morphology Studies

Understanding the interactions and morphology of products obtained for specific applications is essential in order to facilitate the future development of improved, higher-quality products by varying the processing conditions [55,56]. Coupling techniques for the determination of chemical composition with techniques for the determination of morphology, topography, internal structure, and other surface-specific features enables a comprehensive analysis of bioactive coatings. Furthermore, such a characterization provides insight into the relationships of the obtained physiochemical properties with drug delivery and biological activity results.

2.1. Techniques for the Determination of the Chemical Composition of Coatings

2.1.1. ToF-SIMS Analyses

ToF-SIMS is an analytical technique for analyzing surfaces up to a few nanometers in depth. The technique is based on measuring the intensity of selected ions as a function of the mass-to-charge (m/z) ratio of the ions. The ions are sputtered from the surface of a solid material that is stable under an ultra-high vacuum. This material is bombarded with high-energy primary ions. Hydrogen can also be analyzed using SIMS, which is frequently a disadvantage of other surface analytical techniques. Following XPS and Auger electron spectroscopy, SIMS is probably the third most widely used technique for surface analysis. The surface is usually bombarded (primary beam) with Bi+ ions (Bi2+ or Bi3+ ions are also used, depending on the type of sample). The bombardment with a primary ion beam slowly sputters the surface, producing mainly neutral atoms and a small proportion of positive (and negative) secondary ions—these are then separated in a mass analyzer to measure the mass spectrum. Thus, the mass spectrum can be the mass spectrum of the positive ions or the mass spectrum of the negative ions. Nowadays, SIMS devices using a time-of-flight (ToF) analyzer with a mass resolution of 30,000 are already available. Furthermore, a substantially higher mass resolution can be achieved in combination with an Orbitrap mass analyzer. The exceptional strength of the SIMS technique is the acquisition of 2D and 3D images. Typically, the image is obtained on an area of 500 by 500 microns at a resolution of 512 by 512 pixels. In this case, each pixel image represents an area of less than 1 micron [57,58,59].
The ToF-SIMS technique is very useful in the characterization of bioactive coatings as it provides insight into the surface composition and elemental/molecular distribution. The use of this technique was demonstrated for a bioactive coating composed of polymethacrylates and sodium deoxycholate that was LbL-loaded with NSAID diclofenac (DCF) and applied on AISI 316LVM stainless steel and Ti6Al4V. Both polymer- and DCF-specific molecular signals or their fragments were identified in the negative ion and positive ion ToF-SIMS spectra. The DCF distribution in the coating was in the form of needle-like crystals, which was determined by 2D imaging, as depicted in Figure 1 [57].
Moreover, Michiardi et al. [60] reported a linear correlation of the ToF-SIMS intensities at m/z corresponding to S, SO, and TiO3H2 (which were specific to the components in the coatings) and the XPS atomic percentage concentrations of S and Ti, suggesting the use of the ToF-SIMS technique for quantification purposes. In general, however, due to the complex matrix effects, the latter is unusual for the ToF-SIMS technique. On the other hand, ToF-SIMS signals are more selective for species in bioactive coatings compared with XPS signals. Furthermore, ToF-SIMS enables 3D imaging and the determination of the spatial distribution of species inside bioactive coatings. The latter is obtained by means of depth profiling using a secondary ion beam for sputtering (e.g., gas cluster ion beam (GCIB) and possibly also C60+/C60++ for organic materials, and Ar+, O2+, Cs+, Ga+ sputter beams for inorganic materials) associated with intermediate 2D imaging in pulsed mode. With the recent development of a GCIB sputtering source, the depth profiling of organic materials without significant changes in the material chemistry during sputtering provides new opportunities for material characterization, making this evolving technique very useful for the analysis of bioactive coatings in the future [58,59].
An example of ToF-SIMS 3D depth profiling has been presented for RF magnetron-sputtered CaP coatings of different thicknesses on Mg alloy implants to confirm the successful deposition and 3D distribution of species in coatings with a thickness of 70 nm and 210 nm [61]. Moreover, depth profiling, which indicates the different intensities of phase-associated ions over time, has been shown to be useful in detecting different phase transitions, starting with the surface of plasma-deposited coatings embedded with silver nanoparticles, followed by the implant material. Depth profiling additionally allowed a detailed analysis of aging in saline solution (0.15 M NaCl) after 60 days. A decreased thickness of the coating and the release of silver during aging in aqueous solution were reported. Furthermore, an increased 35Cl signal was detected near the surface, indicating that the plasma coating is rich in chlorine [62].

2.1.2. XPS Analysis

XPS is a surface analysis technique, commonly used to characterize bioactive coatings on surgical implants, as it provides qualitative information on the elemental composition and valence state of the elements present in the bioactive coating [46]. In addition, it offers the possibility of quantitative analysis, which is not possible with the ToF-SIMS technique, for example. Most of the studies are performed with an Al Kα excitation source, and the scale is corrected at a binding energy (BE) of 284.8 eV (some employ 285.0 eV) based on the C-C/C-H signal in the C 1s spectrum of the analyzed species containing such features in their structure or due to the presence of adventitious carbonaceous species on the surface. XPS is a surface-sensitive method that provides information for a sample thickness of about 1–10 nm (depending on the angle of analysis and the inelastic mean free path of electrons traveling from the analyte through the surface layer). It is considered the most widely used technique for surface analysis in general and is usually used to perform survey and HR spectral measurements, XPS parallel imaging, GCIB, or monoatomic argon ion sputtering in association with XPS spectra measurements. After obtaining an XPS image, various chemometric techniques can be used to determine the distribution of phases on the surface [63].
In addition to ToF-SIMS, XPS depth profiling can be used to evaluate changes in the elemental composition, oxidation state, and formation of specific bonds with sputtering time. By measuring the depth of the crater created during sputtering (e.g., using AFM or 3D-profilomery), the sputtering depth can be determined. In this context, a low-damage GCIB ion source is often used, as the combination of XPS and GCIB has greatly expanded the range of materials that can be analyzed in depth by allowing the progressive removal of the surface without excessive chemical damage [64,65]. However, to the best of the authors’ knowledge, GCIB has been employed only once for bioactive coating analysis [66].
Using XPS, it is possible to assess the composition of bioactive coatings and thus the success rate of their deposition [61,67]. For example, XPS was used to investigate the AZ31 Mg alloy coated with calcium phosphate (CaP) of 70 nm and 210 nm thickness, which were prepared by means of RF magnetron sputtering. XPS high-resolution (HR) Mg 1s spectra for the uncoated AZ31 Mg alloy exhibited an intensive peak at a BE of 1304 eV for Mg and at a BE of 1307 eV for MgO. The presence of the CaP-coated alloy was confirmed by means of the corresponding Ca 2p and P 2p peaks [61]. XPS can also be used to evaluate the formation of an apatite layer after the immersion of the coating in simulated body fluids (SBFs). HR spectra were recorded for hybrid organic–inorganic TEOS–MTES (tetraethylorthosilicate–methyltriethoxysilane) sol-gel coatings applied on AISI 316L stainless steel implant material. Based on the Fe 2p, O 1s, Ca 2p, and P 2p HR spectrum measurements for the samples immersed in SBF, the in vitro bioactivity was confirmed by formation of apatite on the implants. In addition, XPS was used to determine the Ca/P, O/P, and O/Ca ratios for all samples after their immersion in SBF, confirming the formation of HA [68]. Using XPS, insights into the chemical interactions during the formation of the coating can be gained, which is crucial for understanding the final performance of the coating [69,70,71]. De Santis et al. [69] used XPS to analyze Ti implant samples with TNT-Cen (n = 1, 3, 6, 9, and 12, based on the number of depositions) coatings. It was reported that Ti was fully oxidized to Ti4+ due to the pure TNTs employed. Furthermore, it was observed that the Ce3+ ions from the precursor solution formed Ti-O-Ce bridges. The Ce3+/Ce4+ ratio was measured as it was found that this controls the enzyme-like behavior of the oxide. This ratio was found to be approx. 1:1, which is desirable and demonstrates the importance of both ions, since Ce4+ allows greater anti-inflammatory and osteogenic activity, whereas Ce3+ is able to bind phosphate species. In another study, XPS was used to determine the composition of rhBMP-2 immobilized on glycidyl methacrylate (GMA) prepared on a Ti substrate via initiated chemical vapor deposition (iCVD) [71]. XPS analysis of the bare Ti surface showed the most intense peaks for Ti 2p, C 1s, O 1s, and a less intense peak for N 1s. Ti 2p and N 1s disappeared with the deposition of the pGMA coating; however, the N 1s peak reappeared after the deposition of rhBMP-2 (a N at.% of 5.1% was reported). The strong chemical bonding of rhBMP-2 with pGMA was confirmed by determining the N/O ratio compared to rhBMP-2 physically adsorbed on the Ti substrate. The Ti-pGMA-BMP-2 sample exhibited a significantly higher N/O ratio, confirming the successful immobilization of rhBMP-2 on Ti-pGMA by an epoxide ring-opening reaction. Moreover, using XPS, the effect of the pretreatment of the bare implant surface can be evaluated prior to coating application. Hong et al. [72] identified the functional groups formed on the polyether ether ketone (PEEK) substrate after its treatment with sand blasting and acid etching. Subsequently, bioactive glass (BG) and chitosan (CH) were applied through dip coating to investigate the adhesion of the coating on the substrate. Using XPS, it was found that acid etching of the surface of the PEEK substrate contributed to the formation of the oxyl groups and consequently to the hydrophilicity of the surface and enhanced the spreading of the BG-CH coating solution.

2.1.3. FTIR/ATR-FTIR

Fourier transform infrared spectroscopy (FTIR) is an affordable technique that can be used to characterize and identify various organic and inorganic materials. If certain species absorb the IR light of a molecule, there must be a net change in the dipole moment when the molecule vibrates or rotates. Only in this manner can the alternating electric field of light interact with the molecule and cause a change in the amplitude of one vibrational state. The vibrations occur at different wavenumbers (or frequencies) and are specific to certain bonds, thus serving as a characteristic tool for identifying particular species. The typical FTIR spectrum shows transmittance or absorbance (%) on the y-axis and wavenumbers (cm−1) on the x-axis, and consists of a series of peaks, each representing specific chemical bonds. Since the location of the peak (usually in the wavenumber range from 4000 to 600 cm−1) represents the specific chemical feature, whereas the height of the peak depends on the concentration of that species, both qualitative and quantitative analyses can be performed. It has to be emphasized that even though quantitative information can be obtained using FTIR, the latter is not used frequently [73,74,75,76,77,78].
Traditionally, IR spectroscopy has been used to characterize materials by transmitting IR radiation through the sample. In recent years, attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) has attracted much attention due to the ease of sample preparation, its improved S/N ratio, and the ability to collect measurements in the presence of water [79,80]. The sample is brought into close contact with a transparent crystalline material (ATR crystal) with a high refractive index. As shown in Figure 2, the IR radiation is internally reflected several times before reaching the detector. The internal reflectance results in penetrating radiation, known as an evanescent wave, which extends beyond the crystal, penetrates a few micrometers into the sample, and is attenuated in the regions of the IR spectrum where the sample absorbs energy. The attenuated energy of the evanescent wave is passed back to the IR beam, and finally the attenuation of the beam, called the attenuated total reflectance, is measured by the detector [77,79].
In the characterization of bioactive coatings, FTIR/ATR-FTIR can be used to provide information regarding the chemical composition of such coatings and the bonding that occurs during deposition, whereas in multilayer coatings the number of bilayers can be assessed according to the increased absorbance intensity [67,69,82,83,84]. Moreover, this technique can provide information regarding bioactivity. Using ATR-FTIR, the bioactivity of prepared coatings was confirmed by signals related to PO43, indicating apatite, in a study by De Santis et al. [69] after ceria was combined with TNTs and soaked in SBF at 37 °C for 8 days. The technique can also offer information on whether the drug was successfully incorporated into the bioactive coatings and whether it was physically or chemically bound to the coatings [32,34,85,86,87,88,89,90]. In a study by Kiran et al. [87], coatings of poly(ε-caprolactone) (PCL) nanofibers loaded with HA and rifampicin were electrospun on a Ti substrate. FTIR analysis revealed that the drug remained intact in the system and that little to no dihydroxylation occurred in the case of HA, as indicated by the OH related peaks in the spectra. Moreover, using FTIR, the chemical composition of the coatings can be compared before and after immersion in SBF during in vitro drug release testing, focusing on the degradation of the coating and the completeness of the drug release [39,91]. However, the major drawback of this technique is its inability to distinguish between functional groups when the peaks in the spectra overlap [82,92]. Table 1 shows the functional groups and corresponding wavenumbers (cm−1) for some typical bioactive coating materials and the drugs contained in the coating materials.

2.2. Techniques for the Determination of Morphology, Topography, and Internal Structure

2.2.1. AFM (At Nanoscale)/Profilometry (Larger Area)

By means of the AFM technique, completely nonconducting substances can be studied, which is not possible with the STM technique. Compared to scanning tunnelling microscopy (STM), with AFM forces are measured, rather than current. It works on the principle of measuring forces between the tip and the sample. The forces between the tip and the sample can be short-range or long-range. AFM can achieve a magnification of up to 1,000,000 times, and the distance can be measured in the vertical direction. The advantage of AFM over SEM is the true 3D resolution of the profile and the atomic resolution capabilities. AFM can be performed under atmospheric conditions, in a vacuum, and in liquids. The AFM instrument consists of a cantilever (often made of silicon nitride or silicon or tungsten) that has a sharp tip with a radius of curvature of a few nm (i.e., a very sharp tip). When the tip approaches a certain surface (e.g., in AFM contact mode), atomic forces act between them, causing the cantilever to bend, which is measured via the reflection of the laser beam. The forces that affect AFM measurement vary: van der Waals, electrostatic, magnetic, capillary, ionic, and repulsive forces. The AFM technique is often used in biomedical applications [98].
When applying bioactive coatings to metal substrates, AFM provides an opportunity to characterize the topography and measure the roughness parameters, both of which have an important influence on the osseointegration and interfacial stability of the implants [68,99,100]. Table 2 summarizes a number of studies focusing on the preparation of bioactive coatings on metallic substrates that have been characterized using AFM. The coating deposition technique and implant and coating materials are given, along with the AFM measurement setup and the results obtained.

2.2.2. SEM/EDX (SAXS)

SEM is used to visually characterize the morphology of organic and inorganic materials on a nanometer to micrometer scale using a narrow electron beam that rasters a scan pattern on the sample’s surface. HR grayscale images with up to 300,000-times (1,000,000-times has also been reported) magnification can be obtained through the detection of the secondary electrons and the backscattered electrons from a sample surface coated with gold or palladium ions [103,104,105].
This technique, therefore, allows a comparison of the morphological characteristics of bare metal implants with those of coated implants [34,40,87,106], as well as a comparison of prepared bioactive coatings with different compositions [107]. It can additionally help to determine the morphological changes of coatings at different time intervals in SBF after in vitro drug release tests [108]. In addition to the morphology and microstructure analysis of the coating surface [88,92,109] or cross sections [67,83,91], the thickness of the coatings and the adhesion of osteoblasts on coated implants can be investigated [67,110,111]. For example, Eawsakul et al. [110] used SEM to measure the thickness of PLGA/BMP-2 coating on Ti and to study osteoblast adhesion. The results showed the promotion of cell growth with an increasing amount of BMP-2 entrapped on the implants. Moreover, SEM enables the determination of the diameters of pores, nanotubes, or other active ingredient carriers, as well as the calculation of particle size and distribution when loading coatings with active ingredients [39,86,94,112]. The nanoparticle size distribution is an important parameter in the design of the coating system, since the release and degradation of the active compound in SBF depends on the availability of the surface reactive area in contact with the surrounding media. Aydemir et al. [39] used SEM to determine the particle size and distribution of an electrophoretically deposited chitosan-gelatin coating with silica-gentamicin nanoparticles on surgical grade stainless steel. The shape and distribution of the particles were analyzed by means of digital image processing using an automatic algorithm described in a study by Meng et al. [113]. The analysis of nanofiber FE-SEM (FE—field emission) micrographs with ImageJ software additionally allows the calculation of the pore surface area and porosity percentage [112].
Although SEM provides visual information, it is not a quantitative technique on its own. However, when combined with other techniques, valuable data can be obtained [114]. Energy dispersive X-ray spectroscopy (EDXS, frequently abbreviated only EDX or EDS) is performed in association with SEM and provides quantitative data (based on the intensity of the emitted X-rays). By measuring the intensity of the X-rays, it is possible to produce chemical maps, as well as to obtain quantitative data on the elemental composition of the bare substrate and coatings as an atomic percentage (at. %) [61,83,105,115]. For example, Acheson at al. [61] used SEM/EDXS to determine the elemental composition and to calculate the Ca/P ratio for CaP coatings. On the other hand, Ballarre et al. [68] used small-angle X-ray scattering (SAXS) to analyze TEOS-MTES sol-gel coatings on AISI 316L stainless steel. They were able to determine the values of mean mineral thickness and the degree of orientation of mineral particles in old cortical bone and the newly formed bone after implantation. SAXS analyzes the elastic scattering behavior of X-rays as they pass through the sample and measures their scattering at small angles (0.1°–10°) [116]. Quantification is performed based on nanoscale density differences and information can be obtained for systematic structural analysis, such as particle shape, thickness, orientation, and arrangement in composite coatings [117,118].

2.2.3. TEM

TEM also employs an electron beam to obtain high magnification images (like SEM). However, it differs from SEM in regard to (1) its ability to obtain higher resolution, (2) its main principle, as the electron beam (100–1000 keV) is transmitted through a sample, losing energy as the electrons pass through electron-dense regions, which is detected with the help of a fluorescent screen, and (3) its difficulty obtaining 3D information, as the specimen needs to be viewed and scanned from many directions for this purpose [119,120,121].
Using this technique, it is possible to study the substrate surface and structure along with the morphology of the coatings and the loaded drugs [86,122]. Enrofloxacin, which was functionalized on TNTs by -SH and -NH2 surface-grafted groups, was analyzed using TEM. The gaps between the TNTs were found to be filled with the drug, resulting in an indistinct shape of the previously tubular structure [85]. Determination of the size distribution, surface roughness [39], shape, and particle size [99,123], as well as observation of the cross-section morphology, are also possible [124,125]. Furthermore, similarly to SEM, TEM can be coupled with EDXS for the elemental quantification of substrates and coatings [126,127]. For example, an HA coating on a Ti substrate was prepared through a combination of microarc oxidation (MAO) and microwave hydrothermal treatment (MH). The microstructure of the obtained coatings was investigated by means of TEM, the Fast Fourier Transform (FTT) technique was utilized to study the crystal structures, high-angle annular dark field (HAADF) images were obtained to inspect the Z-contrast, and the elemental mapping distribution and line scanning were determined by means of EDXS in combination with the TEM system. After MAO treatment, porous coatings were observed, which were mainly composed of Ca, P, Si, Ti, and O. A large number of HA crystals were visible on the surface after 10 min. of MH treatment; however, when MH treatment was extended to 60 min., the crystals dissolved and Na0.23TiO2 was produced after TiO2 reaction with OH ions [126].

2.2.4. 3D-Tomography

X-ray computed tomography (CT) provides tomographic (cross-sectional) images by scanning specimens with X-rays and processing them on a computer using reconstruction algorithms [128]. Although the application of CT is usually aimed at medical examinations, micro-CT and nano-CT technologies have been used for the characterization of various biomedical materials.
A typical micro-CT device consists of a micro-focus X-ray source, a rotating stage, a flat-panel detector, and a computer. The X-rays penetrate the rotating sample and 2D projections of different angular positions can be obtained. Subsequently, 3D micro-CT image reconstruction is possible by means of processing software, for example, by using the Feldkamp–Davis–Kress (FDK) algorithm [129,130]. This has been proven useful in gaining insight into the morphology of bioactive coatings, usually focusing on the determination of porosity [131,132]. The corrosion rate of implant materials can also be assessed. In a study in which an AZ31 alloy was coated with CaP coatings of varying thickness, volumetric analysis of the uncoated and coated AZ31 samples was performed using micro-CT after they had been immersed in SBF for 14 days. The observed volume loss was greater in the case of bare samples, indicating that the CaP coatings successfully serve as a protective barrier that reduces corrosion in AZ31 alloys [61]. Nevertheless, the technique has been primarily used to quantify bone growth by segregating bone tissue from the implant after in vivo implantation and to calculate the percentage of regenerated bone volume/total volume (BV/TV) [133,134,135,136]. Qiao et al. [137] fabricated 3D-printed Ti6Al4V coated with platelet-rich plasma (PRP) and implanted it into rabbit models. Months after the implantation, micro-CT images confirmed an increase in the amount of tissue present. In another study, strontium-substituted hardystonite (Sr-HT) ceramic coatings were applied to a Ti alloy. The new bone formation was evaluated for the obtained coated implant, along with the HA-coated and uncoated Ti alloy. Figure 3 shows the micro-CT images 12 weeks after implantation, with the highest amount of newly formed tissue clearly seen in the case of the Sr-HT ceramic coatings [138].
Nano-CT differs from micro-CT in the utilization of a nano-focus X-ray source. It performs scans with a nanometer-scale resolution and therefore yields images of greater detail. It is also evident that nano-CT provides better 3D spatial visualization than conventional micro-CT, SEM, or AFM methods [139]. It offers insights into the morphology (e.g., crystallinity and porosity) of bioactive materials prepared under different conditions [140,141,142] and can be used to evaluate bone growth after implantation, similarly to micro-CT examinations. In an in vivo study carried out by Cuijpers et al. [143], the authors compared micro- and nano-CT techniques for the assessment of newly formed bone tissue after the implantation of Ti-coated PMMA implants. It was discovered that although nano-CT provided significantly higher histomorphological details of the implant and surrounding tissues, the quantification of the newly formed tissues (such as bone area, bone-implant contact, and bone volume percentage) was more representative in the case of micro-CT due to the larger samples that can be measured with this technique (in the centimeter range). Therefore, both of these techniques have certain advantages and should be used in a complementary manner.

2.3. QCM

Quartz crystal microbalance (QCM) is a technique that measures the change in frequency that is proportional (according to the Sauerbrey equation) to the change in mass in the nanogram-to-microgram range, and can be used to determine the amount of material adsorbed on a substrate surface in real time. A decrease in the vibration frequency indicates an increase in the thickness of the adsorbed material. The device consists of a piezoelectric quartz crystal located between the top and bottom electrodes, and starts to vibrate upon the application of potential, which causes the crystal to vibrate at a resonance frequency [144,145,146,147].
QCM is often used to evaluate the adsorption or desorption of coatings on a substrate. For example, it was recently reported that the protein amelogenin adsorbs better on a Ti surface when the Ti is nano-modified to form titania nanosheets [148].
Different QCM variations are also available. In particular, quartz crystal microbalances with dissipation monitoring (QCM-D) have gained popularity in recent years as this approach allows the measurement of adsorbed mass and viscoelasticity. Monitoring the change in resonance frequency (Δf) and the dissipation factor (ΔD) for several overtones is performed by recording the oscillation decay curve after the power is turned off [149]. QCM-D has been used to obtain information regarding the build-up of novel organic-inorganic LbL coatings based on BG, CHI, and hyaluronic acid modified with catechol groups. The viscoelastic properties were evaluated based on the Voigt model, whereas the thickness was calculated by fitting the Δf and ΔD by implementing the Simplex algorithm [150]. In addition, QCM-D has been utilized to evaluate the adsorption and stability of novel bioactive coatings of CHI and anionic surfactant 77KS, which served as a drug delivery system for amoxicillin and were applied to polydimethylsiloxane, i.e., Δf and ΔD were observed at the 3rd overtone, the first indicating the mass adsorption of the different combinations of the prepared coatings, and the second the viscoelasticity. Using QCM-D, the successful adsorption of prepared bioactive coatings with or without amoxicillin on the substrate was observed due to the physical and hydrophobic interactions. In contrast, the influence of the UV/ozone activation of the substrate and the presence of NaCl were found to be ineffective [151].

2.4. Coating Adhesion Measurements

The American Society for Testing and Materials (ASTM) defines adhesion as a condition in which one surface is attached to another as a result of interfacial bonding [152]. Methods for determining adhesion can be divided into three categories, namely, nucleation, mechanical, and miscellaneous methods. Nucleation methods are suitable for the determination of basic or atomic adhesion, whereas mechanical and miscellaneous methods are more suitable for the determination of practical adhesion. Adhesion measurements can be displayed as the force per unit area or as the work/energy required to separate the coating from the substrate. The work of adhesion is given by Equation (1):
W a = γ A + γ B γ AB
where W a is the work of adhesion, γ A is the specific surface energy of the coating, γ B is the specific surface energy of the substrate, and γ AB is the specific surface energy of the phase boundary between the coating and the substrate. If the work of adhesion is positive, the coating is well attached to the substrate, and the adhesion is sufficient, and vice versa if the work of adhesion is negative [53]. Various qualitative and quantitative methods are available to measure the practical adhesion [153]. It has to be pointed out that the results are comparable if the measurements are carried out with the same method and under the same conditions.
Some examples of qualitative adhesion tests, which are usually based on subjective judgement, are the knife test, bend test, and tape test. The knife adhesion test is described by the ASTM D6677 standard and is used to determine the adhesion between thick layers of soft organic coatings applied to solid substrates. The test is performed using a knife to make two incisions in the coating layer in the shape of a cross at a 30° to 45° angle. The tip of the knife is then inserted into the cross section in the coating in an attempt to remove the coating from the substrate. Adhesion is subjectively evaluated by the force required to remove the coating from the substrate, ranging from 0 to 10 using the criteria referred to in the given table [154,155]. The bend test is used for a variety of coatings to determine overall flexibility and adhesion and is based on bending the sample under shear stress. The test is performed with a round pin of which the diameter is at least four times as thick as the sample. The pin exerts a force on the sample to bend it until the coating is damaged [153]. The tape test is described by ASTM D3359 [156] and is most commonly used for thin organic and polymeric coatings. A sharp blade is used to cut a specific pattern (X-cut or cross-hatch cut) into the coating, followed by a pressure-sensitive adhesive tape with well-defined adhesive properties that is adhered to the coating. The adhesive tape is then peeled off of a sample and observed to see if it contains any coating residue [153,157]. Chen et al. [158] used a cross-hatch tape test to qualitatively determine the adhesion between a 316L stainless steel substrate and an alginate/Bioglass® composite coating obtained via electrophoretic deposition (EPD) with direct current (DC) or alternating current (AC). It was found that the maximum value of the peeled area was not greater than 15%. The number of EPD cycles decreased the adhesion strength when using DC EPD and remained unchanged when using AC EPD.
Quantitative tests, on the other hand, offer the ability to measure adhesion accurately and are therefore appropriate for more detailed experimental work. Some examples of quantitative tests are the scratch test, the pull-off test, the four-point bend test, and the peel test. The scratch test is described by the ASTM D2197 standard [159]. Its application is limited to measuring the adhesion of thin films on smooth and flat surfaces. The test is based on the horizontal movement of the sample under a weighted stylus tip to produce a scratch on the coating surface. The test can be performed with a constant load or with a linear increase in the load until the coating is removed from the substrate. The result obtained is the critical value of the load that occurs when the coating separates from the substrate. It can be determined by observing the scratch under a microscope, by measuring the coefficient of friction, or by analyzing the measured acoustic emission [160,161,162]. Wu et al. [163] applied sphene and HA coatings on Ti6Al4V disks and performed a scratch test to quantify the adhesion using a constant load and optical microscopy. The sphene coatings maintained their integrity and exhibited only minor scratches up to a load of 80 g-force, compared to the HA coatings, which failed at a load of 25 g-force, and thus exhibited better adhesion properties. Booth et al. [164], on the other hand, used the progressive load scratch test to evaluate the adhesion of their multilayered coatings consisting of alternating nanocrystalline (NCD) and microcrystalline (MDC) diamond to a Ti6Al4V substrate. The load rate was 2 N/s up to 60 N, whereas the scratch tracks were examined using a microscope. The results showed a high level of adhesion for all coatings; however, the highest critical load value was found for the single-layered NCD coatings. The pull-off test is described by ASTM D4541 [165] and is suitable for the majority of coatings. It consists of a dolly attached vertically to the coating and a screw that is gradually loaded by winding until the coating is pulled off the substrate. The results obtained are the critical tensile strength in psi or MPa [162,166]. Sharifnabi [167] employed the pull-off test to measure the adhesion between medical-grade AISI 316L stainless steel and a Mg-substituted fluorapatite coating obtained by means of the sol-gel dip coating technique. An automatic adhesion tester (PosiTest AT-A, DeFelsko) was employed to perform a pull-off test. A satisfactory adhesion strength was demonstrated as the maximum pressure of 4 MPa did not affect the coating. The four-point bend adhesion test provides quantitative results compared to the basic bend test, as it offers information on the deformation or load at which the coating is damaged. The method is based on the use of pins that are in contact with the sample at four points, which is placed horizontally between them. Two cylinders are placed at the bottom of the sample and two at the top, which are used to increase the surface tension by exploiting the load until damage to the coating occurs [166,168]. Hong et al. [72] used the standard pull-off and four-point bend tests to measure adhesion, with the PEEK implant substrate coated with chitosan/Bioglass® composite coatings using the dip-coating method. The four-point bend test was additionally selected to simulate the stress conditions of spinal implants. The results for both tests were comparable and showed drastically improved adhesion by subjecting the substrate to sandblasting and acid etching treatment, compared to acid etching treatment alone. The peel test can be used for flexible coatings that can be bent at least 90° and have a coating thickness not exceeding 0.125 mm. The test is performed by attaching a handle to the coating and gradually applying a force to peel the coating from the substrate at either a 90° or 180° angle. The result is usually presented as the force required to peel the coating from the substrate per unit length of sample (N/25 mm or N/50 mm, depending on the width of the sample) [166,169,170]. Kurzweg and Heimann [171] demonstrated that the peel test is suitable for determining the adhesion between a Ti6Al4V substrate coated with thin layers of titania and zirconia (bond coating), followed by a thick layer of atmospheric plasma-sprayed HA. The results showed that the adhesion strength was significantly improved with the intervening bonding layers (especially titania layers) compared to HA deposited directly on a Ti6Al4V substrate.

2.5. Contact Angle Measurements

Contact angle measurements are performed to describe the ability of a solid substrate to repel a liquid and are considered to be a quantitative measurement of surface wettability [172,173]. Depending on the application, different methods can be used, such as the sessile drop method, the captive bubble method, the Wilhelmy plate method, etc. [174,175,176,177]. However, the main principle is to drop liquid (water) onto the surface and analyze the shape of the obtained drop, which changes as a result of various surface properties (surface roughness, surface energies, surface chemistry, and surface coatings) [173]. In the most common sessile drop measurements, the droplet is placed on a solid surface until it reaches an equilibrium of forces, meaning that the sum of the interfacial tensions in the plane of the surface is zero. This phenomenon is explained by Young’s equation (Equation (2)):
θ sv θ sl θ lv · cos θ = 0
where θ sv represents the solid-vapor surface tension, θ sl represents the solid-liquid surface tension, and θ lv represents the liquid-vapor surface tension [178]. The droplet is observed through a combination of precision optics, cameras, and sophisticated software, which allow easy and rapid determination of the contact angle [179]. The contact angle ( θ ) is geometrically defined as the angle formed by the liquid droplet at the three-phase boundary where liquid, gas, and solid intersect [173]. The method is well established for plain metal substrates, various films, and coatings [179,180]. It indicates the hydrophilicity and hydrophobicity of the material at issue, depending on the contact angle measured. Surfaces with a contact angle greater than 90° are considered hydrophobic (water repellent), whereas substrates with a contact angle less than 90° are defined as hydrophilic [179,180]. The hydrophilicity/hydrophobicity of coated implants has been reported to be closely related to the biological response, as it affects cell adhesion, cell proliferation, and protein adsorption (Figure 4) [180,181,182,183,184].
Values of 35°–80° have been found to be optimal for materials in biomedical applications, as cell adhesion and proliferation tend to be enhanced at high hydrophilicity, whereas values below 35° negatively affect protein attachment, which is known to cause thrombogenicity [181,185,186,187]. It has been shown that the coating of implants and their various surface modifications can improve hydrophilicity and thus accelerate osseointegration. For example, a variation in surface topography has been shown to influence surface wettability. In a study where CHI/BG coatings were deposited on TiAlV alloy by means of electrophoretic deposition, the effect of different surface treatment of TiAlV was observed through contact angle measurements. It was found that grit-blasted substrates were favorable as the wettability was significantly increased [181]. Furthermore, in another study, it was reported that pre-treatment of PEEK implants with an accelerated neutral atom beam (ANAB) resulted in nanometer-scale surface modifications and consequently increased surface hydrophilicity [188]. On the other hand, Cordero-Arias et al. [189] discovered higher hydrophilicity of composite chitosan/nano titania (nTiO2) on stainless steel by including higher concentrations of nTiO2. Therefore, it can be concluded that the hydrophilicity of implant surfaces can be improved by applying certain types of coatings. The hydrophilicity of metal-based implants has been improved by the application of TNT/nTiO2 [85], HA [190], BG [191], and various polymers [32,87,192]. Nevertheless, although contact angle measurements can provide information on the interactions between the surface and gases or liquids, other techniques should be employed to provide more detailed characterization of chemical properties, as described in the sections above [178].

3. Controlled Release

Over the years, several studies have focused on the preparation of localized drug release strategies for orthopedic implants by incorporating drugs into implant coatings [32,108,193,194]. Some of the advantages of a localized drug release over systemic drug delivery are the achievement of fewer side effects by avoiding systemic drug exposure, higher bioavailability as the drug is administered directly to the target tissue, a lower dosage needed to achieve the desired effect, and the ability to customize the release kinetics [38,195]. These benefits can be achieved through controlled release systems in which drugs or other active ingredients are incorporated into a carrier (implant coating) and are slowly and continuously released into the surrounding media over the desired period of time. The release rate is determined either by the microstructure of the carrier and the intermolecular interactions between the carrier and the drug, or by the environmental factors in which the carrier is located, such as the pH and temperature of the body fluids [196,197].
In general, controlled release systems can be classified into four classical mechanisms, namely, diffusion-controlled, chemically-controlled, solvent-activated, and magnetically-controlled mechanisms [196]. A diffusion-controlled mechanism is a mass transport mechanism that plays a major role in most controlled release systems and can be analyzed using Fick’s diffusion theory. Equation (3) represents Fick’s well-known First Law, which can be used to determine diffusion in a single direction, with the basic idea that a drug diffuses from a site of higher concentration to an adjacent site of lower concentration:
J i * = D ip d c i t , z d z
where J i * represents the molar flux of the drug with respect to the molar average velocity of the system, c i represents the drug concentration, t represents time, z represents the thickness of the film, and D represents the diffusion coefficient or diffusivity [196,198]. The diffusion-controlled mechanism is further classified into a reservoir or a monolithic system, depending on the inner structure of the drug delivery system. The reservoir type refers to a drug being incorporated into a carrier in a core-shell arrangement, whereas the monolithic type refers to the homogeneous distribution of a drug in a carrier matrix [198]. A chemically controlled mechanism includes erodible systems, in which the drug is incorporated into a biodegradable carrier, with its release being affected by the degradation rate of the carrier material, or a pendant chain system, in which the drug is hydrolytically or enzymatically linked to a polymer and is released into the surrounding media after the linkage is broken [196]. The solvent-activated mechanism is determined by the permeation rate of the solvent and is further divided into osmosis and swelling. The osmotic delivery system consists of a carrier, acting as a semipermeable membrane, and an osmotic core containing an active agent. The solvent diffuses through the membrane to the core, generating the osmotic pressure and consequently regulates drug release into the surrounding media in zero-order kinetics [199,200]. The swelling mechanism, on the other hand, allows the release of the drug after the solvent diffuses into the carrier containing the dispersed drug, causing the carrier material to swell and release the drug in a controlled manner. Finally, magnetically-controlled systems contain magnetic beads in addition to drugs dispersed in a carrier. When exposed to an oscillating external magnetic field, the drug is released at a different (higher) rate than the usual diffusion-controlled rate [201].
In vitro drug release tests have been shown to be useful in the early stages of controlled-release formulations because they allow the prediction of release behavior in vivo and the optimization of kinetics to achieve a controlled release. In addition, they reduce the experimental time, lower expenses, and are undoubtedly more ethical. Much research effort has been invested into the development of appropriate in vitro release testing methods and technologies to ensure simplicity, batch-to-batch reproducibility, and comparability with real in vivo body conditions [202,203]. In this regard, a variety of methods have been developed for in vitro drug release testing, generally involving the immersion of the carrier containing the selected drug in the prepared dissolution media, such as SBF, under well-defined conditions. This step is followed by sampling at different time intervals, supplying fresh dissolution media, the filtration/centrifugation of the sample taken [204], and drug detection in the sample using UV-Vis spectroscopy [108], enzyme-linked immunosorbent assay (ELISA) [40], or high-performance liquid chromatography (HPLC) [92]. Seven variants of United States Pharmacopeia (USP) apparatuses [202] (USP apparatus type I is shown on Figure 5) or other designs (e.g., Franz diffusion cells) are currently the most frequently used for in vitro drug release testing [57,203].

3.1. Release Models

Understanding the release kinetics is of the utmost importance in the development of controlled-release formulations, as it describes the in vitro and consequently the in vivo release processes and therefore enables the effective design and optimization of drug carriers [202].
The result of in vitro release tests are different kinetic profiles, which show the dependence of the concentration of the released drug and the corresponding release time. The release kinetics depends on the crystallinity, particle size, solubility, and amount of the drug [205]. A simple method to determine the kinetic model is to fit the experimental data (the concentration of the released drug as a function of time) to various linearized mathematical models, plot a graph, perform a linear regression of the plotted graph, and determine the correlation coefficient, R, and the square of the correlation coefficient, R2. The most appropriate kinetic model is the one with the R2 value closest to 1.00 [206]. Some of the most common kinetic models are presented in Table 3.
It should be noted that although zero-order release is usually favored due to drug release at constant concentrations over time, it is not representative in drug release formulations. The most frequently obtained release profiles are triphasic, with phase I representing a burst release of the unencapsulated drug at the surface, with phase II being a slow release dominated by diffusion processes, and phase III a faster release of the drug as a result of nanofiber erosion, as shown in Figure 6 [38,209].

3.2. Drug Release from Bioactive Coatings

In the studies performed to date, a wide range of antihyperlipidemics [94], analgesic and anti-inflammatory drugs [91,108], antibiotics [210], bisphosphonates [30], selective estrogen receptor modulators [211], and growth factors [40] have been incorporated into medical implant coatings with the aim of preventing postoperative complications and inducing adequate acceptance and integration of the implant into the body. The drug release is strongly influenced by factors such as the type and physiochemical properties of the selected drug, the coating and the implant, the deposition technique, the focal tissue environment, and the method of incorporating the drug into the coatings, indicating different interactions between the drug and the coating material [38,212]. Hence, the drug release kinetics of the different novel coating-implant systems from recent studies are summarized in Table 4.
The major limitation of the currently manufactured bioactive coatings is their frequent inability to achieve the desired controlled and sustained release of drugs [212,216]. As shown in Table 4, the use of different coating materials and deposition techniques to modify their properties (e.g., composition, thickness, porosity, surface functionalization, etc.) can significantly affect the drug release kinetics in SBF. In most cases, the obtained release profiles indicate an initial fast release, followed by a slower release, and finally a plateau, all ranging from a few hours to a few months. It can be seen that some coating formulations prepared via electrospinning [87,108], electrophoretic deposition [41,114], dip coating [40], LbL [102], and anodization [214] may provide a drug release for more than a month.

4. Conclusions

Advances in materials science, cell biology, and pharmacology have facilitated the rapid development of novel bioactive coatings for orthopedic implants with the aim of promoting bone ingrowth into predominantly biologically inert implants. It should be emphasized that mechanically stable, biocompatible, antimicrobial, anticorrosive, osteoinductive, and osteoconductive coatings have already been produced through the careful selection of coating materials, drugs, and coating deposition techniques. In addition, the design of drug-eluting implant coatings for controlled drug delivery is also on the rise due to their important attributes as to the on-site prevention of postoperative complications, fewer side effects, and higher bioavailability at lower drug doses. Although the tremendous progress in relation to current bioactive coatings is evident, much research is still needed before they enter clinical practice.
In the development of multifunctional bioactive coatings, the optimization of their chemical interactions, structure, topography, surface wettability, mechanical properties, and drug release kinetics is fundamental and can only be assessed through proper characterization. On this basis, this review focused on the common characterization techniques used for interaction and morphology studies, as well as their basic principles and performance in the case of bioactive coatings. In addition, the concept of controlled drug delivery, the typical kinetics models, and recent advances in the field of drug-releasing bioactive coatings are addressed. Nowadays, the cellular response and the degree of biomineralization can be foreseen as a function of the surface properties of the coatings. Characterization of the topography and morphology of both the coatings and the cells adhering to them is performed by mean of AFM, SEM, TEM, and 3D tomography, whereas surface chemistry is determined using advanced techniques such as ToF-SIMS and XPS, which in combination with GCIB allow depth profiling without major sample damage, or by ATR-FTIR analysis. Although the aforementioned techniques allow the qualitative analysis of the obtained coatings, quantitative analysis is only possible with XPS, SEM/EDXS, and ATR-FTIR. In contrast, the advantages of ToF-SIMS are its low detection limit, its determination of the presence of isotopes, and the possibility of 2D and 3D imaging to show the distribution of the components in the samples. Measurements of coating adsorption or desorption are possible with the QCM technique. A wide range of versatile quantitative adhesion tests have been developed to monitor the mechanical durability of coatings and their adhesion to implants. Since cell adhesion and the resulting osseointegration are significantly influenced by surface wettability, CA measurements are routinely performed to determine the degree of hydrophilicity/hydrophobicity of various surfaces. Surface analysis of coated orthopedic implants is essential in order to understand the final composition of the coatings and their influence on simulated biological processes. Future opportunities lie in the development of coatings that simultaneously promote osseointegration and allow personalized multi-drug delivery, in which the release kinetics, drug type, drug concentration, and consequently therapeutic efficacy are tailored to the needs of the individual. The constantly evolving state-of-the-art characterization techniques will undoubtedly eliminate the current limitations and enable the optimized development of high-value medical implants.

Author Contributions

Conceptualization: K.A.K. and M.F.; funding acquisition: M.F.; methodology: K.A.K. and M.F.; project administration: M.F.; resources: M.F.; software: K.A.K.; supervision: M.F.; visualization: K.A.K. and M.F.; writing—original draft: K.A.K. and M.F.; writing—review and editing: K.A.K. and M.F. All authors have read and agreed to the published version of the manuscript.

Funding

The authors would like to acknowledge the Slovenian Research Agency for its financial support through grant numbers P2-0046 and J1-2470 and the scholarship awarded to K.A.K.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The raw/processed data required to reproduce these findings cannot be shared at this time due to legal or ethical reasons.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

ACalternating current
AFMatomic force microscopy
ANABaccelerated neutral atom beam
ASTMAmerican Society for Testing and Materials
ATR-FTIRattenuated total reflection Fourier transform infrared spectroscopy
BEbinding energy
BGbioactive glass
CAcontact angle
CaPcalcium phosphate
CHIchitosan
CMCcarboxymethyl cellulose
CTcomputed tomography
DCdirect current
DCFdiclofenac
EDX/EDXSenergy dispersive X-ray spectroscopy
FTIRFourier transform infrared spectroscopy
FTTFast Fourier Transform
GCIBgas cluster ion beam
GMAglycidyl methacrylate
HAHydroxyapatite
HAADFhigh-angle annular dark field
LbLlayer-by-layer
MAOmicroarc oxidation
MCDmicrocrystalline diamond
MHmicrowave hydrothermal treatment
NCDnanocrystalline diamond
NSAIDsnonsteroidal anti-inflammatory drugs
nTiO2nano titania
PAApoly(acrylic acid)
PCLpoly(ε-caprolactone)
PEEKpolyether ether ketone
PLGApoly(lactic-co glycolic acid)
PLLpoly(l-lysine)
PVApolyvinyl alcohol
QCMquartz crystal microbalance
QCM-Dquartz crystal microbalance with dissipation monitoring
SAXSsmall-angle X-ray scattering
SBFsimulated body fluids
SEMscanning electron microscopy
Sr-HTstrontium-substituted hardystonite
STMscanning tunnelling microscopy
TEMtransmission electron microscopy
TEOS–MTEStetraethylorthosilicate–methyltriethoxysilane
TNTstitania nanotubes
ToF-SIMStime-on-flight secondary ion mass spectrometry
USPUnited States Pharmacopeia
XPSX-ray photoelectron spectroscopy
β-CDbeta cyclodextrin

References

  1. Zhang, B.G.X.; Myers, D.E.; Wallace, G.G.; Brandt, M.; Choong, P.F.M. Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings. Int. J. Mol. Sci. 2014, 15, 11878–11921. [Google Scholar] [CrossRef] [Green Version]
  2. Saini, M.; Singh, Y.; Arora, P.; Arora, V.; Jain, K. Implant biomaterials: A comprehensive review. World J. Clin. Cases WJCC 2015, 3, 52. [Google Scholar] [CrossRef] [PubMed]
  3. Mitra, I.; Bose, S.; Dernell, W.S.; Dasgupta, N.; Eckstrand, C.; Herrick, J.; Yaszemski, M.J.; Goodman, S.B.; Bandyopadhyay, A. 3D Printing in alloy design to improve biocompatibility in metallic implants. Mater. Today 2021, 45, 20–34. [Google Scholar] [CrossRef] [PubMed]
  4. Albrektsson, T.; Johansson, C. Osteoinduction, osteoconduction and osseointegration. Eur. Spine J. 2001, 10, S96–S101. [Google Scholar]
  5. Geng, Z.; Li, Z.; Cui, Z.; Wang, J.; Yang, X.; Liu, C. Novel Bionic Topography with MiR-21 Coating for Improving Bone-Implant Integration through Regulating Cell Adhesion and Angiogenesis. Nano Lett. 2020, 20, 7716–7721. [Google Scholar] [CrossRef]
  6. Rosales-Leal, J.I.; Rodriguez-Valverde, M.A.; Mazzaglia, G.; Ramón-Torregrosa, P.J.; Díaz-Rodríguez, L.; García-Martínez, O.; Vallecillo-Capilla, M.; Ruiz, C.; Cabrerizo-Vílchez, M.A. Effect of roughness, wettability and morphology of engineered titanium surfaces on osteoblast-like cell adhesion. Colloids Surf. A Physicochem. Eng. Asp. 2010, 365, 222–229. [Google Scholar] [CrossRef]
  7. Kulangara, K.; Leong, K.W. Substrate topography shapes cell function. Soft Matter 2009, 5, 4072–4076. [Google Scholar] [CrossRef]
  8. Chen, Y.; Xu, Z.; Smith, C.; Sankar, J. Recent advances on the development of magnesium alloys for biodegradable implants. Acta Biomater. 2014, 10, 4561–4573. [Google Scholar] [CrossRef] [PubMed]
  9. Perez, L.M.; Lalueza, P.; Monzon, M.; Puertolas, J.A.; Arruebo, M.; Santamaría, J. Hollow porous implants filled with mesoporous silica particles as a two-stage antibiotic-eluting device. Int. J. Pharm. 2011, 409, 1–8. [Google Scholar] [CrossRef]
  10. Prefac, G.-A.; Milea, M.-L.; Vadureanu, A.-M.; Muraru, S.; Dobrin, D.-I.; Isopencu, G.-O.; Jinga, S.-I.; Raileanu, M.; Bacalum, M.; Busuioc, C. CeO2 Containing Thin Films as Bioactive Coatings for Orthopaedic Implants. Coatings 2020, 10, 642. [Google Scholar] [CrossRef]
  11. Mehnath, S.; Arjama, M.; Rajan, M.; Premkumar, K.; Karthikeyan, K.; Jeyaraj, M. Mineralization of bioactive marine sponge and electrophoretic deposition on Ti-6Al-4V implant for osteointegration. Surf. Coat. Technol. 2020, 392, 125727. [Google Scholar] [CrossRef]
  12. Nuswantoro, N.F.; Juliadmi, D.; Fajri, H.; Manjas, M.; Suharti, N.; Tjong, D.H.; Affi, J. Electrophoretic Deposition Performance of Hydroxyapatite Coating on Titanium Alloys for Orthopedic Implant Application. In Proceedings of the Materials Science Forum; Trans Tech Publications: Stafa-Zurich, Switzerland, 2020; pp. 69–81. [Google Scholar]
  13. Nichol, T.; Callaghan, J.; Townsend, R.; Stockley, I.; Hatton, P.V.; Le Maitre, C.; Smith, T.J.; Akid, R. The antimicrobial activity and biocompatibility of a controlled gentamicin-releasing single-layer sol-gel coating on hydroxyapatite-coated titanium. Bone Jt. J. 2021, 103, 522–529. [Google Scholar] [CrossRef]
  14. Ansari, Z.; Kalantar, M.; Kharaziha, M.; Ambrosio, L.; Raucci, M.G. Polycaprolactone/fluoride substituted-hydroxyapatite (PCL/FHA) nanocomposite coatings prepared by in-situ sol-gel process for dental implant applications. Prog. Org. Coat. 2020, 147, 105873. [Google Scholar] [CrossRef]
  15. Escobar, A.; Muzzio, N.; Moya, S.E. Antibacterial Layer-by-Layer Coatings for Medical Implants. Pharmaceutics 2021, 13, 16. [Google Scholar] [CrossRef]
  16. Gulati, K.; Ramakrishnan, S.; Aw, M.S.; Atkins, G.J.; Findlay, D.M.; Losic, D. Biocompatible polymer coating of titania nanotube arrays for improved drug elution and osteoblast adhesion. Acta Biomater. 2012, 8, 449–456. [Google Scholar] [CrossRef] [PubMed]
  17. Ordikhani, F.; Zustiak, S.P.; Simchi, A. Surface Modifications of Titanium Implants by Multilayer Bioactive Coatings with Drug Delivery Potential: Antimicrobial, Biological, and Drug Release Studies. JOM 2016, 68, 1100–1108. [Google Scholar] [CrossRef]
  18. Ballarre, J.; Aydemir, T.; Liverani, L.; Roether, J.A.; Goldmann, W.; Boccaccini, A.R. Versatile bioactive and antibacterial coating system based on silica, gentamicin, and chitosan: Improving early stage performance of titanium implants. Surf. Coat. Technol. 2020, 381, 125138. [Google Scholar] [CrossRef]
  19. Kaur, G.; Kumar, V.; Baino, F.; Mauro, J.C.; Pickrell, G.; Evans, I.; Bretcanu, O. Mechanical properties of bioactive glasses, ceramics, glass-ceramics and composites: State-of-the-art review and future challenges. Mater. Sci. Eng. C 2019, 104, 109895. [Google Scholar] [CrossRef]
  20. Zarghami, V.; Ghorbani, M.; Bagheri, K.P.; Shokrgozar, M.A. Prevention the formation of biofilm on orthopedic implants by melittin thin layer on chitosan/bioactive glass/vancomycin coatings. J. Mater. Sci. Mater. Med. 2021, 32, 75. [Google Scholar] [CrossRef] [PubMed]
  21. Harb, S.V.; Bassous, N.J.; de Souza, T.A.; Trentin, A.; Pulcinelli, S.H.; Santilli, C.V.; Webster, T.J.; Lobo, A.O.; Hammer, P. Hydroxyapatite and β-TCP modified PMMA-TiO2 and PMMA-ZrO2 coatings for bioactive corrosion protection of Ti6Al4V implants. Mater. Sci. Eng. C 2020, 116, 111149. [Google Scholar] [CrossRef]
  22. Yao, Q.; Jiang, Y.; Tan, S.; Fu, X.; Li, B.; Liu, L. Composition and bioactivity of calcium phosphate coatings on anodic oxide nanotubes formed on pure Ti and Ti-6Al-4V alloy substrates. Mater. Sci. Eng. C 2020, 110, 110687. [Google Scholar] [CrossRef]
  23. Bhong, S.Y.; More, N.; Choppadandi, M.; Kapusetti, G. Review on carbon nanomaterials as typical candidates for orthopaedic coatings. SN Appl. Sci. 2019, 1, 76. [Google Scholar] [CrossRef] [Green Version]
  24. Maver, U.; Xhanari, K.; Žižek, M.; Gradišnik, L.; Repnik, K.; Potočnik, U.; Finšgar, M. Carboxymethyl cellulose/diclofenac bioactive coatings on AISI 316LVM for controlled drug delivery, and improved osteogenic potential. Carbohydr. Polym. 2020, 230, 115612. [Google Scholar] [CrossRef] [PubMed]
  25. Li, Y.; Yang, Y.; Li, R.; Tang, X.; Guo, D.; Qing, Y.; Qin, Y. Enhanced antibacterial properties of orthopedic implants by titanium nanotube surface modification: A review of current techniques. Int. J. Nanomed. 2019, 14, 7217. [Google Scholar] [CrossRef] [Green Version]
  26. Xiao, W.; Fu, H.; Rahaman, M.N.; Liu, Y.; Bal, B.S. Hollow hydroxyapatite microspheres: A novel bioactive and osteoconductive carrier for controlled release of bone morphogenetic protein-2 in bone regeneration. Acta Biomater. 2013, 9, 8374–8383. [Google Scholar] [CrossRef] [Green Version]
  27. Zhang, J.; Li, J.; Jia, G.; Jiang, Y.; Liu, Q.; Yang, X.; Pan, S. Improving osteogenesis of PLGA/HA porous scaffolds based on dual delivery of BMP-2 and IGF-1 via a polydopamine coating. RSC Adv. 2017, 7, 56732–56742. [Google Scholar] [CrossRef] [Green Version]
  28. Gan, Q.; Zhu, J.; Yuan, Y.; Liu, H.; Qian, J.; Li, Y.; Liu, C. A dual-delivery system of pH-responsive chitosan-functionalized mesoporous silica nanoparticles bearing BMP-2 and dexamethasone for enhanced bone regeneration. J. Mater. Chem. B 2015, 3, 2056–2066. [Google Scholar] [CrossRef] [PubMed]
  29. Peter, B.; Pioletti, D.P.; Laïb, S.; Bujoli, B.; Pilet, P.; Janvier, P.; Guicheux, J.; Zambelli, P.Y.; Bouler, J.M.; Gauthier, O. Calcium phosphate drug delivery system: Influence of local zoledronate release on bone implant osteointegration. Bone 2005, 36, 52–60. [Google Scholar] [CrossRef] [Green Version]
  30. Wan, P.; Wang, W.; Zheng, L.; Qin, L.; Yang, K. One-step electrodeposition synthesis of bisphosphonate loaded magnesium implant: A strategy to modulate drug release for osteoporotic fracture healing. J. Mater. Sci. Technol. 2021, 78, 92–99. [Google Scholar] [CrossRef]
  31. Pan, C.-J.; Pang, L.-Q.; Gao, F.; Wang, Y.-N.; Liu, T.; Ye, W.; Hou, Y.-H. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface. Mater. Sci. Eng. C 2016, 63, 333–340. [Google Scholar] [CrossRef]
  32. Maver, T.; Mastnak, T.; Mihelič, M.; Maver, U.; Finšgar, M. Clindamycin-Based 3D-Printed and Electrospun Coatings for Treatment of Implant-Related Infections. Materials 2021, 14, 1464. [Google Scholar] [CrossRef]
  33. Yusoff, M.F.M.; Kadir, M.R.A.; Iqbal, N.; Hassan, M.A.; Hussain, R. Dipcoating of poly (ε-caprolactone)/hydroxyapatite composite coating on Ti6Al4V for enhanced corrosion protection. Surf. Coat. Technol. 2014, 245, 102–107. [Google Scholar] [CrossRef]
  34. Mishra, S.K.; Kannan, S. Development, mechanical evaluation and surface characteristics of chitosan/polyvinyl alcohol based polymer composite coatings on titanium metal. J. Mech. Behav. Biomed. Mater. 2014, 40, 314–324. [Google Scholar] [CrossRef] [PubMed]
  35. Omar, S.A.; Ballarre, J.; Castro, Y.; Martinez Campos, E.; Schreiner, W.; Durán, A.; Cere, S.M. 58S and 68S sol-gel glass-like bioactive coatings for enhancing the implant performance of AZ91D magnesium alloy. Surf. Coat. Technol. 2020, 400, 126224. [Google Scholar] [CrossRef]
  36. Stigter, M.; de Groot, K.; Layrolle, P. Incorporation of tobramycin into biomimetic hydroxyapatite coating on titanium. Biomaterials 2002, 23, 4143–4153. [Google Scholar] [CrossRef]
  37. Wang, T.; Weng, Z.; Liu, X.; Yeung, K.W.; Pan, H.; Wu, S. Controlled release and biocompatibility of polymer/titania nanotube array system on titanium implants. Bioact. Mater. 2017, 2, 44–50. [Google Scholar] [CrossRef]
  38. Kamaly, N.; Yameen, B.; Wu, J.; Farokhzad, O.C. Degradable Controlled-Release Polymers and Polymeric Nanoparticles: Mechanisms of Controlling Drug Release. Chem. Rev. 2016, 116, 2602–2663. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  39. Aydemir, T.; Liverani, L.; Pastore, J.I.; Ceré, S.M.; Goldmann, W.H.; Boccaccini, A.R.; Ballarre, J. Functional behavior of chitosan/gelatin/silica-gentamicin coatings by electrophoretic deposition on surgical grade stainless steel. Mater. Sci. Eng. C 2020, 115, 111062. [Google Scholar] [CrossRef]
  40. Pan, H.; Han, J.J.; Park, Y.-D.; Cho, T.H.; Hwang, S.J. Effect of sustained release of rhBMP-2 from dried and wet hyaluronic acid hydrogel carriers compared with direct dip coating of rhBMP-2 on peri-implant osteogenesis of dental implants in canine mandibles. J. Cranio-Maxillofac. Surg. 2016, 44, 116–125. [Google Scholar] [CrossRef] [PubMed]
  41. Pishbin, F.; Mouriño, V.; Flor, S.; Kreppel, S.; Salih, V.; Ryan, M.P.; Boccaccini, A.R. Electrophoretic Deposition of Gentamicin-Loaded Bioactive Glass/Chitosan Composite Coatings for Orthopaedic Implants. ACS Appl. Mater. Interfaces 2014, 6, 8796–8806. [Google Scholar] [CrossRef]
  42. Kim, H.W.; Knowles, J.C.; Kim, H.E. Porous scaffolds of gelatin–hydroxyapatite nanocomposites obtained by biomimetic ap-proach: Characterization and antibiotic drug release. J. Biomed. Mater. Res. Part B Appl. Biomater. 2005, 74, 686–698. [Google Scholar] [CrossRef]
  43. Graham, D.J.; Wagner, M.S.; Castner, D.G. Information from complexity: Challenges of TOF-SIMS data interpretation. Appl. Surf. Sci. 2006, 252, 6860–6868. [Google Scholar] [CrossRef]
  44. Hofmann, S. Quantitative depth profiling in surface analysis: A review. Surf. Interface Anal. 1980, 2, 148–160. [Google Scholar] [CrossRef]
  45. Wirtz, T.; Philipp, P.; Audinot, J.N.; Dowsett, D.; Eswara, S. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: From traditional 2D and 3D imaging to correlative microscopy. Nanotechnology 2015, 26, 434001. [Google Scholar] [CrossRef] [PubMed]
  46. Seah, M.P. A review of the analysis of surfaces and thin films by AES and XPS. Vacuum 1984, 34, 463–478. [Google Scholar] [CrossRef]
  47. Seah, M. The quantitative analysis of surfaces by XPS: A review. Surf. Interface Anal. 1980, 2, 222–239. [Google Scholar] [CrossRef]
  48. Valand, R.; Tanna, S.; Lawson, G.; Bengtström, L. A review of Fourier Transform Infrared (FTIR) spectroscopy used in food adulteration and authenticity investigations. Food Addit. Contam. Part A 2020, 37, 19–38. [Google Scholar] [CrossRef] [PubMed]
  49. Smith, J.; Larson, C.; Campbell, S. Recent applications of SEM and AFM for assessing topography of metal and related coatings—A review. Trans. IMF 2011, 89, 18–27. [Google Scholar] [CrossRef]
  50. Dong, Z.L.; Khor, K.A.; Quek, C.; White, T.J.; Cheang, P. TEM and STEM analysis on heat-treated and in vitro plasma-sprayed hydroxyapatite/Ti-6Al-4V composite coatings. Biomaterials 2003, 24, 97–105. [Google Scholar] [CrossRef]
  51. Seong, H.; Choi, S.; Matusik, K.E.; Kastengren, A.L.; Powell, C.F. 3D pore analysis of gasoline particulate filters using X-ray tomography: Impact of coating and ash loading. J. Mater. Sci. 2019, 54, 6053–6065. [Google Scholar] [CrossRef]
  52. Alassi, A.; Benammar, M.; Brett, D. Quartz Crystal Microbalance Electronic Interfacing Systems: A Review. Sensors 2017, 17, 2799. [Google Scholar] [CrossRef] [Green Version]
  53. Chalker, P.R.; Bull, S.J.; Rickerby, D.S. A review of the methods for the evaluation of coating-substrate adhesion. Mater. Sci. Eng. A 1991, 140, 583–592. [Google Scholar] [CrossRef]
  54. Eral, H.; Oh, J. Contact angle hysteresis: A review of fundamentals and applications. Colloid Polym. Sci. 2013, 291, 247–260. [Google Scholar] [CrossRef]
  55. Liu, F.; Gu, Y.; Shen, X.; Ferdous, S.; Wang, H.-W.; Russell, T.P. Characterization of the morphology of solution-processed bulk heterojunction organic photovoltaics. Prog. Polym. Sci. 2013, 38, 1990–2052. [Google Scholar] [CrossRef]
  56. Guo, Q. Polymer Morphology: Principles, Characterization, and Processing; John Wiley & Sons: Hoboken, NJ, USA, 2016. [Google Scholar]
  57. Finšgar, M.; Kovač, J.; Maver, U. The development and characterization of bioactive coatings for local drug delivery in orthopedic applications. Prog. Org. Coat. 2021, 158, 106350. [Google Scholar] [CrossRef]
  58. Finšgar, M. Advanced surface analysis using GCIB-C60++-tandem-ToF-SIMS and GCIB-XPS of 2-mercaptobenzimidazole corrosion inhibitor on brass. Microchem. J. 2020, 159, 105495. [Google Scholar] [CrossRef]
  59. Winograd, N. Gas Cluster Ion Beams for Secondary Ion Mass Spectrometry. Annu. Rev. Anal. Chem. 2018, 11, 29–48. [Google Scholar] [CrossRef] [PubMed]
  60. Michiardi, A.; Hélary, G.; Nguyen, P.-C.T.; Gamble, L.J.; Anagnostou, F.; Castner, D.G.; Migonney, V. Bioactive polymer grafting onto titanium alloy surfaces. Acta Biomater. 2010, 6, 667–675. [Google Scholar] [CrossRef] [Green Version]
  61. Acheson, J.; McKillop, S.; Lemoine, P.; Boyd, A.; Meenan, B. Control of magnesium alloy corrosion by bioactive calcium phosphate coating: Implications for resorbable orthopaedic implants. Materialia 2019, 6, 100291. [Google Scholar] [CrossRef]
  62. Zanna, S.; Saulou, C.; Mercier-Bonin, M.; Despax, B.; Raynaud, P.; Seyeux, A.; Marcus, P. Ageing of plasma-mediated coatings with embedded silver nanoparticles on stainless steel: An XPS and ToF-SIMS investigation. Appl. Surf. Sci. 2010, 256, 6499–6505. [Google Scholar] [CrossRef]
  63. Ratner, B.D.; McElroy, B.J. Electron Spectroscopy for Chemical Analysis: Applications in the Biomedical Sciences. In Spectroscopy in the Biomedical Sciences; John Wiley & Sons: West Sussex, UK, 2018; pp. 107–140. [Google Scholar]
  64. Cumpson, P.J.; Portoles, J.F.; Barlow, A.J.; Sano, N.; Birch, M. Depth profiling organic/inorganic interfaces by argon gas cluster ion beams: Sputter yield data for biomaterials, in-vitro diagnostic and implant applications. Surf. Interface Anal. 2013, 45, 1859–1868. [Google Scholar] [CrossRef]
  65. Sano, N.; Barlow, A.J.; Tsakonas, C.; Cranton, W.; Cumpson, P.J. Optimal conditions for gas cluster ion beams in studying inorganic interface species: Improved chemical information at a ZnO interface. Surf. Interface Anal. 2016, 48, 575–579. [Google Scholar] [CrossRef]
  66. Vokoun, D.; Racek, J.; Kadeřávek, L.; Kei, C.C.; Yu, Y.S.; Klimša, L.; Šittner, P. Atomic Layer-Deposited TiO2 Coatings on NiTi Surface. J. Mater. Eng. Perform. 2018, 27, 572–579. [Google Scholar] [CrossRef]
  67. Pei, X.; Zeng, Y.; He, R.; Li, Z.; Tian, L.; Wang, J.; Wan, Q.; Li, X.; Bao, H. Single-walled carbon nanotubes/hydroxyapatite coatings on titanium obtained by electrochemical deposition. Appl. Surf. Sci. 2014, 295, 71–80. [Google Scholar] [CrossRef]
  68. Ballarre, J.; Manjubala, I.; Schreiner, W.H.; Orellano, J.C.; Fratzl, P.; Ceré, S. Improving the osteointegration and bone–implant interface by incorporation of bioactive particles in sol–gel coatings of stainless steel implants. Acta Biomater. 2010, 6, 1601–1609. [Google Scholar] [CrossRef] [PubMed]
  69. De Santis, S.; Sotgiu, G.; Porcelli, F.; Marsotto, M.; Iucci, G.; Orsini, M. A Simple Cerium Coating Strategy for Titanium Oxide Nano-tubes’ Bioactivity Enhancement. Nanomaterials 2021, 11, 445. [Google Scholar] [CrossRef]
  70. Lai, M.; Cai, K.; Zhao, L.; Chen, X.; Hou, Y.; Yang, Z. Surface Functionalization of TiO2 Nanotubes with Bone Morphogenetic Protein 2 and Its Synergistic Effect on the Differentiation of Mesenchymal Stem Cells. Biomacromolecules 2011, 12, 1097–1105. [Google Scholar] [CrossRef]
  71. Youn, Y.H.; Lee, S.J.; Choi, G.R.; Lee, H.R.; Lee, D.; Heo, D.N.; Kim, B.-S.; Bang, J.B.; Hwang, Y.-S.; Correlo, V.M. Simple and facile preparation of recombinant human bone morphogenetic protein-2 immobilized titanium implant via initiated chemical vapor deposition technique to promote osteogenesis for bone tissue engineering application. Mater. Sci. Eng. C 2019, 100, 949–958. [Google Scholar] [CrossRef] [PubMed]
  72. Hong, W.; Guo, F.; Chen, J.; Wang, X.; Zhao, X.; Xiao, P. Bioactive glass–chitosan composite coatings on PEEK: Effects of surface wettability and roughness on the interfacial fracture resistance and in vitro cell response. Appl. Surf. Sci. 2018, 440, 514–523. [Google Scholar] [CrossRef] [Green Version]
  73. Asmatulu, R.; Khan, W.S. (Eds.) Chapter 13—Characterization of electrospun nanofibers. In Synthesis and Applications of Electrospun Nanofibers; Elsevier: Amsterdam, The Netherlands, 2019; pp. 257–281. [Google Scholar]
  74. Titus, D.; Samuel, E.J.J.; Roopan, S.M. Nanoparticle characterization techniques. In Green Synthesis, Characterization and Applications of Nanoparticles; Elsevier: Amsterdam, The Netherlands, 2019; pp. 303–319. [Google Scholar]
  75. Berthomieu, C.; Hienerwadel, R. Fourier transform infrared (FTIR) spectroscopy. Photosynth. Res. 2009, 101, 157–170. [Google Scholar] [CrossRef]
  76. Song, K. 4—Interphase characterization in rubber nanocomposites. In Progress in Rubber Nanocomposites; Thomas, S., Maria, H.J., Eds.; Woodhead Publishing: Duxford, UK, 2017; pp. 115–152. [Google Scholar]
  77. Skoog, D.A.; Holler, F.J.; Crouch, S.R. Principles of Instrumental Analysis; Cengage Learning: Boston, MA, USA, 2017. [Google Scholar]
  78. Kowalczuk, D.; Pitucha, M. Application of FTIR Method for the Assessment of Immobilization of Active Substances in the Matrix of Biomedical Materials. Materials 2019, 12, 2972. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  79. FT-IR Spectroscopy Attenuated Total Reflectance (ATR) (PDF). Available online: https://cmdis.rpi.edu/sites/default/files/ATR_FTIR.pdf (accessed on 2 November 2021).
  80. Margenot, A.J.; Calderón, F.J.; Goyne, K.W.; Mukome, F.N.D.; Parikh, S.J. IR Spectroscopy, Soil Analysis Applications. In Encyclopedia of Spectroscopy and Spectrometry, 3rd ed.; Lindon, J.C., Tranter, G.E., Koppenaal, D.W., Eds.; Academic Press: Oxford, UK, 2017; pp. 448–454. [Google Scholar]
  81. Shai, Y. ATR-FTIR studies in pore forming and membrane induced fusion peptides. Biochim. Biophys. Acta 2013, 1828, 2306–2313. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  82. Akhtar, M.A.; Mariotti, C.E.; Conti, B.; Boccaccini, A.R. Electrophoretic deposition of ferulic acid loaded bioactive glass/chitosan as antibacterial and bioactive composite coatings. Surf. Coat. Technol. 2021, 405, 126657. [Google Scholar] [CrossRef]
  83. Huang, Y.; Hao, M.; Nian, X.; Qiao, H.; Zhang, X.; Zhang, X.; Song, G.; Guo, J.; Pang, X.; Zhang, H. Strontium and copper co-substituted hydroxyapatite-based coatings with improved antibacterial activity and cytocompatibility fabricated by electrodeposition. Ceram. Int. 2016, 42, 11876–11888. [Google Scholar] [CrossRef]
  84. Likibi, F.; Jiang, B.; Li, B. Biomimetic nanocoating promotes osteoblast cell adhesion on biomedical implants. J. Mater. Res. 2008, 23, 3222–3228. [Google Scholar] [CrossRef] [Green Version]
  85. Huang, P.; Wang, J.; Lai, S.; Liu, F.; Ni, N.; Cao, Q.; Liu, W.; Deng, D.Y.; Zhou, W. Surface modified titania nanotubes containing anti-bacterial drugs for controlled delivery nanosystems with high bioactivity. J. Mater. Chem. B 2014, 2, 8616–8625. [Google Scholar] [CrossRef]
  86. Khoshnood, N.; Zamanian, A.; Massoudi, A. Mussel-inspired surface modification of titania nanotubes as a novel drug delivery system. Mater. Sci. Eng. C 2017, 77, 748–754. [Google Scholar] [CrossRef] [PubMed]
  87. Kiran, A.S.K.; Kizhakeyil, A.; Ramalingam, R.; Verma, N.K.; Lakshminarayanan, R.; Kumar, T.S.; Doble, M.; Ramakrishna, S. Drug loaded electrospun polymer/ceramic composite nanofibrous coatings on titanium for implant related infections. Ceram. Int. 2019, 45, 18710–18720. [Google Scholar] [CrossRef]
  88. Li, X.; Zhitomirsky, I. Deposition of poly(methyl methacrylate) and composites containing bioceramics and bioglass by dip coating using isopropanol-water co-solvent. Prog. Org. Coat. 2020, 148, 105883. [Google Scholar] [CrossRef]
  89. Zhao, P.; Liu, H.; Deng, H.; Xiao, L.; Qin, C.; Du, Y.; Shi, X. A study of chitosan hydrogel with embedded mesoporous silica nanoparticles loaded by ibuprofen as a dual stimuli-responsive drug release system for surface coating of titanium implants. Colloids Surf. B Biointerfaces 2014, 123, 657–663. [Google Scholar] [CrossRef] [PubMed]
  90. Rožanc, J.; Žižek, M.; Milojević, M.; Maver, U.; Finšgar, M. Dexamethasone-Loaded Bioactive Coatings on Medical Grade Stainless Steel Promote Osteointegration. Pharmaceutics 2021, 13, 568. [Google Scholar] [CrossRef]
  91. Horvat, G.; Xhanari, K.; Finšgar, M.; Gradišnik, L.; Maver, U.; Knez, Ž.; Novak, Z. Novel ethanol-induced pectin–xanthan aerogel coatings for orthopedic applications. Carbohydr. Polym. 2017, 166, 365–376. [Google Scholar] [CrossRef] [PubMed]
  92. Jahanmard, F.; Croes, M.; Castilho, M.; Majed, A.; Steenbergen, M.; Lietaert, K.; Vogely, H.; van der Wal, B.; Stapels, D.; Malda, J. Bactericidal coating to prevent early and delayed implant-related infections. J. Control. Release 2020, 326, 38–52. [Google Scholar] [CrossRef] [PubMed]
  93. Finšgar, M.; Uzunalić, A.P.; Stergar, J.; Gradišnik, L.; Maver, U. Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications. Sci. Rep. 2016, 6, 26653. [Google Scholar] [CrossRef] [PubMed]
  94. Rezk, A.I.; Mousa, H.M.; Lee, J.; Park, C.H.; Kim, C.S. Composite PCL/HA/simvastatin electrospun nanofiber coating on biodegradable Mg alloy for orthopedic implant application. J. Coat. Technol. Res. 2019, 16, 477–489. [Google Scholar] [CrossRef]
  95. Hashemi, A.; Ezati, M.; Mohammadnejad, J.; Houshmand, B.; Faghihi, S. Chitosan Coating of TiO2 Nanotube Arrays for Improved Metformin Release and Osteoblast Differentiation. Int. J. Nanomed. 2020, 15, 4471–4481. [Google Scholar] [CrossRef] [PubMed]
  96. Cordero-Arias, L.; Cabanas-Polo, S.; Goudouri, O.M.; Misra, S.K.; Gilabert, J.; Valsami-Jones, E.; Sanchez, E.; Virtanen, S.; Boccaccini, A.R. Electrophoretic deposition of ZnO/alginate and ZnO-bioactive glass/alginate composite coatings for antimicrobial applications. Mater. Sci. Eng. C 2015, 55, 137–144. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  97. Sasireka, A.; Rajendran, R.; Raj, V. In vitro corrosion resistance and cytocompatibility of minerals substituted apatite/biopolymers duplex coatings on anodized Ti for orthopedic implant applications. Arab. J. Chem. 2020, 13, 6312–6326. [Google Scholar] [CrossRef]
  98. Nandi, T.; Ainavarapu, S.R.K. Applications of atomic force microscopy in modern biology. Emerg. Top. Life Sci. 2021, 5, 103–111. [Google Scholar] [CrossRef]
  99. Zeller, A.; Musyanovych, A.; Kappl, M.; Ethirajan, A.; Dass, M.; Markova, D.; Klapper, M.; Landfester, K. Nanostructured Coatings by Adhesion of Phosphonated Polystyrene Particles onto Titanium Surface for Implant Material Applications. ACS Appl. Mater. Interfaces 2010, 2, 2421–2428. [Google Scholar] [CrossRef]
  100. Burnat, B.; Olejarz, P.; Batory, D.; Cichomski, M.; Kaminska, M.; Bociaga, D. Titanium Dioxide Coatings Doubly-Doped with Ca and Ag Ions as Corrosion Resistant, Biocompatible, and Bioactive Materials for Medical Applications. Coatings 2020, 10, 169. [Google Scholar] [CrossRef] [Green Version]
  101. Brammer, K.S.; Oh, S.; Cobb, C.J.; Bjursten, L.M.; van der Heyde, H.; Jin, S. Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface. Acta Biomater. 2009, 5, 3215–3223. [Google Scholar] [CrossRef]
  102. Verza, B.S.; van den Beucken, J.J.; Brandt, J.V.; Junior, M.J.; Barão, V.A.; Piazza, R.D.; Tagit, O.; Spolidorio, D.M.; Vergani, C.E.; de Avila, E.D. A long-term controlled drug-delivery with anionic beta cyclodextrin complex in layer-by-layer coating for percutaneous implants devices. Carbohydr. Polym. 2021, 257, 117604. [Google Scholar] [CrossRef] [PubMed]
  103. Singh, A.K. (Ed.) Chapter 4—Experimental Methodologies for the Characterization of Nanoparticles. In Engineered Nanoparticles; Academic Press: Boston, MA, USA, 2016; pp. 125–170. [Google Scholar]
  104. Van de Ven, A.L.; Mack, A.; Dunner, K.; Ferrari, M.; Serda, R.E. Chapter one—Preparation, Characterization, and Cellular Associations of Silicon Logic-Embedded Vectors. In Methods in Enzymology; Düzgüneş, N., Ed.; Academic Press: San Diego, CA, USA, 2012; Volume 508, pp. 1–16. [Google Scholar]
  105. Mohammed, A.; Abdullah, A. Scanning electron microscopy (SEM): A review. In Proceedings of the 2018 International Conference on Hydraulics and Pneumatics—HERVEX, Băile Govora, Romania, 7–9 November 2018; pp. 7–9. [Google Scholar]
  106. Tao, B.; Zhao, W.; Lin, C.; Yuan, Z.; He, Y.; Lu, L.; Chen, M.; Ding, Y.; Yang, Y.; Xia, Z. Surface modification of titanium implants by ZIF-8@ Levo/LBL coating for inhibition of bacterial-associated infection and enhancement of in vivo osseointegration. Chem. Eng. J. 2020, 390, 124621. [Google Scholar] [CrossRef]
  107. Xia, K.; Pan, H.; Wang, T.; Ma, S.; Niu, J.; Xiang, Z.; Song, Y.; Yang, H.; Tang, X.; Lu, W. Effect of Ca/P ratio on the structural and corrosion properties of biomimetic Ca/P coatings on ZK60 magnesium alloy. Mater. Sci. Eng. C 2017, 72, 676–681. [Google Scholar] [CrossRef] [PubMed]
  108. Wei, Y.; Liu, Z.; Zhu, X.; Jiang, L.; Shi, W.; Wang, Y.; Xu, N.; Gang, F.; Wang, X.; Zhao, L. Dual directions to address the problem of aseptic loosening via electrospun PLGA@ aspirin nanofiber coatings on titanium. Biomaterials 2020, 257, 120237. [Google Scholar] [CrossRef] [PubMed]
  109. Tolde, Z.; Starý, V.; Cvrček, L.; Vandrovcová, M.; Remsa, J.; Daniš, S.; Krčil, J.; Bačáková, L.; Špatenka, P. Growth of a TiNb adhesion interlayer for bioactive coatings. Mater. Sci. Eng. C 2017, 80, 652–658. [Google Scholar] [CrossRef] [PubMed]
  110. Eawsakul, K.; Tancharoen, S.; Nasongkla, N. Combination of dip coating of BMP-2 and spray coating of PLGA on dental implants for osseointegration. J. Drug Deliv. Sci. Technol. 2021, 61, 102296. [Google Scholar] [CrossRef]
  111. Gkomoza, P.; Vardavoulias, M.; Pantelis, D.; Sarafoglou, C. Comparative study of structure and properties of thermal spray coatings using conventional and nanostructured hydroxyapatite powder, for applications in medical implants. Surf. Coat. Technol. 2019, 357, 748–758. [Google Scholar] [CrossRef]
  112. Khosravi, F.; Khorasani, S.N.; Khalili, S.; Neisiany, R.E.; Ghomi, E.R.; Ejeian, F.; Das, O.; Nasr-Esfahani, M.H. Development of a Highly Proliferated Bilayer Coating on 316L Stainless Steel Implants. Polymers 2020, 12, 1022. [Google Scholar] [CrossRef] [PubMed]
  113. Meng, Y.; Zhang, Z.; Yin, H.; Ma, T. Automatic detection of particle size distribution by image analysis based on local adaptive canny edge detection and modified circular Hough transform. Micron 2018, 106, 34–41. [Google Scholar] [CrossRef] [PubMed]
  114. Amidon, G.E.; Meyer, P.J.; Mudie, D.M. Chapter 10—Particle, Powder, and Compact Characterization. In Developing Solid Oral Dosage Forms, 2nd ed.; Qiu, Y., Chen, Y., Zhang, G.G.Z., Yu, L., Mantri, R.V., Eds.; Academic Press: Boston, MA, USA, 2017; pp. 271–293. [Google Scholar]
  115. Radda’a, N.S.; Goldmann, W.H.; Detsch, R.; Roether, J.A.; Cordero-Arias, L.; Virtanen, S.; Moskalewicz, T.; Boccaccini, A.R. Electrophoretic deposition of tetracycline hydrochloride loaded halloysite nanotubes chitosan/bioactive glass composite coatings for orthopedic implants. Surf. Coat. Technol. 2017, 327, 146–157. [Google Scholar] [CrossRef]
  116. Pilz, I.; Glatter, O.; Kratky, O. Small-angle x-ray scattering. In Methods in Enzymology; Elsevier: Cambridge, MA, USA, 1979; Volume 61, pp. 148–249. [Google Scholar]
  117. Fratzl, P.; Gupta, H.S.; Paris, O.; Valenta, A.; Roschger, P.; Klaushofer, K. Diffracting “stacks of cards”-some thoughts about small-angle scattering from bone. In Scattering Methods and the Properties of Polymer Materials; Springer: Berlin/Heidelberg, Germany, 2005; pp. 33–39. [Google Scholar]
  118. Li, J.; Rong, P.; Huang, Q. Characterization of food materials in multiple length scales using small-angle X-ray scattering and nuclear magnetic resonance: Principle and applications. In Nanotechnology in the Food, Beverage and Nutraceutical Industries; Huang, Q., Ed.; Woodhead Publishing: Cambridge, UK, 2012; pp. 149–176. [Google Scholar]
  119. Misof, B.; Roschger, P.; Fratzl, P. 3.325—Imaging Mineralized Tissues in Vertebrates. In Comprehensive Biomaterials; Ducheyne, P., Ed.; Elsevier: Oxford, UK, 2011; pp. 407–426. [Google Scholar]
  120. Sonia, T.A.; Sharma, C.P. (Eds.) 4—Experimental techniques involved in the development of oral insulin carriers. In Oral Delivery of Insulin; Woodhead Publishing: Cambridge, UK, 2014; pp. 169–217. [Google Scholar]
  121. Warren, J.B.; Panessa-Warren, B.J. A Comparison of Nanometrology Using SEM and TEM. Microsc. Microanal. 2005, 11, 1932–1933. [Google Scholar] [CrossRef] [Green Version]
  122. Gherasim, O.; Grumezescu, A.M.; Grumezescu, V.; Negut, I.; Dumitrescu, M.F.; Stan, M.S.; Nica, I.C.; Holban, A.M.; Socol, G.; Andronescu, E. Bioactive Coatings Based on Hydroxyapatite, Kanamycin, and Growth Factor for Biofilm Modulation. Antibiotics 2021, 10, 160. [Google Scholar] [CrossRef]
  123. Kaya, C. Electrophoretic deposition of carbon nanotube-reinforced hydroxyapatite bioactive layers on Ti–6Al–4V alloys for biomedical applications. Ceram. Int. 2008, 34, 1843–1847. [Google Scholar] [CrossRef]
  124. Lopez-Esteban, S.; Saiz, E.; Fujino, S.; Oku, T.; Suganuma, K.; Tomsia, A.P. Bioactive glass coatings for orthopedic metallic implants. J. Eur. Ceram. Soc. 2003, 23, 2921–2930. [Google Scholar] [CrossRef] [Green Version]
  125. Oh, S.; Daraio, C.; Chen, L.H.; Pisanic, T.R.; Fiñones, R.R.; Jin, S. Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes. J. Biomed. Mater. Res. Part A 2006, 78, 97–103. [Google Scholar] [CrossRef]
  126. Du, Q.; Wei, D.; Wang, S.; Cheng, S.; Wang, Y.; Li, B.; Jia, D.; Zhou, Y. TEM analysis and in vitro and in vivo biological performance of the hydroxyapatite crystals rapidly formed on the modified microarc oxidation coating using microwave hydrothermal technique. Chem. Eng. J. 2019, 373, 1091–1110. [Google Scholar] [CrossRef]
  127. Moreno, L.; Mohedano, M.; Mingo, B.; Arrabal, R.; Matykina, E. Degradation Behaviour of Mg0.6Ca and Mg0.6Ca2Ag Alloys with Bioactive Plasma Electrolytic Oxidation Coatings. Coat. 2019, 9, 383. [Google Scholar] [CrossRef] [Green Version]
  128. Paris, J.L.; Vallet-Regí, M. Chapter 1—Nanostructures for imaging, medical diagnostics and therapy. In Fundamentals of Nanoparticles; Barhoum, A., Hamdy Makhlouf, A.S., Eds.; Elsevier: Amsterdam, The Netherlands, 2018; pp. 1–28. [Google Scholar]
  129. Liu, Y.; Xie, D.; Zhou, R.; Zhang, Y. 3D X-ray micro-computed tomography imaging for the microarchitecture evaluation of porous metallic implants and scaffolds. Micron 2021, 142, 102994. [Google Scholar] [CrossRef]
  130. Feldkamp, L.A.; Davis, L.C.; Kress, J.W. Practical cone-beam algorithm. J. Opt. Soc. Am. 1984, 1, 612–619. [Google Scholar] [CrossRef] [Green Version]
  131. Zhang, J.; Jiang, Z.; Guo, H.; Sun, T.; Chen, A.; Zhou, Y.; He, Y. Function-structure-integrated Ti-HA coatings on TiNbZr with enhanced mechanical properties and bioactivity prepared by spark plasma sintering. Vacuum 2021, 184, 109863. [Google Scholar] [CrossRef]
  132. Baino, F.; Montealegre, M.A.; Örlygsson, G.; Novajra, G.; Vitale-Brovarone, C. Bioactive glass coatings fabricated by laser cladding on ceramic acetabular cups: A proof-of-concept study. J. Mater. Sci. 2017, 52, 9115–9128. [Google Scholar] [CrossRef]
  133. Wang, S.; Li, R.; Li, D.; Zhang, Z.-Y.; Liu, G.; Liang, H.; Qin, Y.; Yu, J.; Li, Y. Fabrication of bioactive 3D printed porous titanium implants with Sr ion-incorporated zeolite coatings for bone ingrowth. J. Mater. Chem. B 2018, 6, 3254–3261. [Google Scholar] [CrossRef]
  134. Jung, H.-D.; Jang, T.-S.; Lee, J.E.; Park, S.J.; Son, Y.; Park, S.-H. Enhanced bioactivity of titanium-coated polyetheretherketone implants created by a high-temperature 3D printing process. Biofabrication 2019, 11, 045014. [Google Scholar] [CrossRef]
  135. He, T.; Cao, C.; Xu, Z.; Li, G.; Cao, H.; Liu, X.; Zhang, C.; Dong, Y. A comparison of micro-CT and histomorphometry for evaluation of osseointegration of PEO-coated titanium implants in a rat model. Sci. Rep. 2017, 7, 16270. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  136. Fu, Q.; Huang, W.; Jia, W.; Rahaman, M.N.; Liu, X.; Tomsia, A.P. Three-Dimensional Visualization of Bioactive Glass-Bone Integration in a Rabbit Tibia Model Using Synchrotron X-ray Microcomputed Tomography. Tissue Eng. Part A 2011, 17, 3077–3084. [Google Scholar] [CrossRef] [Green Version]
  137. Qiao, S.; Sheng, Q.; Li, Z.; Wu, D.; Zhu, Y.; Lai, H.; Gu, Y. 3D-printed Ti6Al4V scaffolds coated with freeze-dried platelet-rich plasma as bioactive interface for enhancing osseointegration in osteoporosis. Mater. Des. 2020, 194, 108825. [Google Scholar] [CrossRef]
  138. Zhang, W.; Wang, G.; Liu, Y.; Zhao, X.; Zou, D.; Zhu, C.; Jin, Y.; Huang, Q.; Sun, J.; Liu, X.; et al. The synergistic effect of hierarchical micro/nano-topography and bioactive ions for enhanced osseointegration. Biomaterials 2013, 34, 3184–3195. [Google Scholar] [CrossRef]
  139. Haugen, H.J.; Qasim, S.B.; Matinlinna, J.P.; Vallittu, P.; Nogueira, L.P. Nano-CT as tool for characterization of dental resin composites. Sci. Rep. 2020, 10, 15520. [Google Scholar] [CrossRef]
  140. Molino, G.; Bari, A.; Baino, F.; Fiorilli, S.; Vitale-Brovarone, C. Electrophoretic deposition of spray-dried Sr-containing mesoporous bioactive glass spheres on glass–ceramic scaffolds for bone tissue regeneration. J. Mater. Sci. 2017, 52, 9103–9114. [Google Scholar] [CrossRef]
  141. Nawaz, Q.; de Pablos-Martín, A.; Martins de Souza e Silva, J.; Berthold, L.; Hurle, K.; Jaimes, A.T.C.; Sitarz, M.; Brauer, D.S.; Boccaccini, A.R. Crystallization study of sol–gel derived 13-93 bioactive glass powder. J. Eur. Ceram. Soc. 2021, 41, 1695–1706. [Google Scholar] [CrossRef]
  142. Jaimes, A.T.C.; de Pablos-Martín, A.; Hurle, K.; Martins de Souza e Silva, J.; Berthold, L.; Kittel, T.; Boccaccini, A.R.; Brauer, D.S. Deepening our understanding of bioactive glass crystallization using TEM and 3D nano-CT. J. Eur. Ceram. Soc. 2021, 41, 4958–4969. [Google Scholar] [CrossRef]
  143. Cuijpers, V.M.; Jaroszewicz, J.; Anil, S.; Al Farraj Aldosari, A.; Walboomers, X.F.; Jansen, J.A. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants. Clin. Oral Implant. Res. 2014, 25, 359–365. [Google Scholar] [CrossRef]
  144. Balasingam, J.A.; Swaminathan, S.; Nazemi, H.; Love, C.; Birjis, Y.; Emadi, A. Chemical Sensors: Gas Sensors, Acoustic Sensors. In Reference Module in Biomedical Sciences; Elsevier: Amsterdam, The Netherlands, 2021. [Google Scholar]
  145. Santoro, K.; Ricciardi, C. Biosensors. In Encyclopedia of Food and Health; Caballero, B., Finglas, P.M., Toldrá, F., Eds.; Academic Press: Oxford, UK, 2016; pp. 430–436. [Google Scholar]
  146. Bridle, H.; Desmulliez, M. Chapter 7—Biosensors for the detection of waterborne pathogens. In Waterborne Pathogens, 2nd ed.; Bridle, H., Ed.; Academic Press: London, UK, 2021; pp. 189–235. [Google Scholar]
  147. Felgueiras, H.P.; Antunes, J.C.; Martins, M.C.L.; Barbosa, M.A. 1—Fundamentals of protein and cell interactions in biomaterials. In Peptides and Proteins as Biomaterials for Tissue Regeneration and Repair; Barbosa, M.A., Martins, M.C.L., Eds.; Woodhead Publishing: Duxford, UK, 2018; pp. 1–27. [Google Scholar]
  148. Terada, C.; Komasa, S.; Kusumoto, T.; Kawazoe, T.; Okazaki, J. Effect of Amelogenin Coating of a Nano-Modified Titanium Surface on Bioactivity. Int. J. Mol. Sci. 2018, 19, 1274. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  149. Redondo-Morata, L.; Losada-Pérez, P.; Giannotti, M.I. Chapter One—Lipid bilayers: Phase behavior and nanomechanics. In Current Topics in Membranes; Levitan, I., Trache, A., Eds.; Academic Press: Cambridge, MA, USA, 2020; Volume 86, pp. 1–55. [Google Scholar]
  150. Rego, S.J.; Vale, A.C.; Luz, G.M.; Mano, J.F.; Alves, N.M. Adhesive bioactive coatings inspired by sea life. Langmuir 2016, 32, 560–568. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  151. Ajdnik, U.; Finšgar, M.; Zemljič, L.F. Characterization of chitosan-lysine surfactant bioactive coating on silicone substrate. Carbohydr. Polym. 2020, 232, 115817. [Google Scholar] [CrossRef]
  152. Rickerby, D. A review of the methods for the measurement of coating-substrate adhesion. Surf. Coat. Technol. 1988, 36, 541–557. [Google Scholar] [CrossRef]
  153. Duncan, B.; Crocker, L. Review of Tests for Adhesion Strength; National Physical Laboratoy: Middlesex, UK, 2001. [Google Scholar]
  154. Vaca-Cortés, E.; Lorenzo, M.A.; Jirsa, J.O.; Wheat, H.G.; Carrasquillo, R.L. Adhesion Testing of Epoxy Coating; Research Report No. 1265-6; Center for Transportation Research: Austin, TX, USA, 1998; pp. 1–129. [Google Scholar]
  155. ASTM D6677; Standard Test Method for Evaluating Adhesion by Knife; ASTM International: West Conshohocken, PA, USA, 2012.
  156. ASTM D3359; Standard Test Methods for Measuring Adhesion by Tape Test; ASTM International: West Conshohocken, PA, USA, 2009.
  157. Valli, J. A review of adhesion test methods for thin hard coatings. J. Vac. Sci. Technol. A Vac. Surf. Film. 1986, 4, 3007–3014. [Google Scholar] [CrossRef]
  158. Chen, Q.; Cordero-Arias, L.E.; Roether, J.A.; Cabanas-Polo, S.; Virtanen, S.; Boccaccini, A.R. Alginate/Bioglass® composite coatings on stainless steel deposited by direct current and alternating current electrophoretic deposition. Surf. Coat. Technol. 2013, 233, 49–56. [Google Scholar] [CrossRef]
  159. ASTM D2197; Standard Test Method for Adhesion of Organic Coatings by Scrape Adhesion; ASTM International: West Conshohocken, PA, USA, 2013.
  160. Laugier, M. The development of the scratch test technique for the determination of the adhesion of coatings. Thin Solid Films 1981, 76, 289–294. [Google Scholar] [CrossRef]
  161. Steinmann, P.A.; Tardy, Y.; Hintermann, H.E. Adhesion testing by the scratch test method: The influence of intrinsic and extrinsic parameters on the critical load. Thin Solid Film. 1987, 154, 333–349. [Google Scholar] [CrossRef]
  162. El-Shabasy, M. Adhesion measurements of thin metallic films: Comparison of the direct pull-off and the scratch methods. Period. Polytech. Electr. Eng. Arch. 1981, 25, 283–290. [Google Scholar]
  163. Wu, C.; Ramaswamy, Y.; Gale, D.; Yang, W.; Xiao, K.; Zhang, L.; Yin, Y.; Zreiqat, H. Novel sphene coatings on Ti–6Al–4V for orthopedic implants using sol–gel method. Acta Biomater. 2008, 4, 569–576. [Google Scholar] [CrossRef] [PubMed]
  164. Booth, L.; Catledge, S.A.; Nolen, D.; Thompson, R.G.; Vohra, Y.K. Synthesis and Characterization of Multilayered Diamond Coatings for Biomedical Implants. Materials 2011, 4, 857–868. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  165. ASTM D4541; Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers; ASTM International: West Conshohocken, PA, USA, 2002.
  166. Maxwell, A. Review of Test Methods for Coating Adhesion; National Physical Laboratory: Middlesex, UK, 2001. [Google Scholar]
  167. Sharifnabi, A.; Fathi, M.; Yekta, B.E.; Hossainalipour, M. The structural and bio-corrosion barrier performance of Mg-substituted fluorapatite coating on 316L stainless steel human body implant. Appl. Surf. Sci. 2014, 288, 331–340. [Google Scholar] [CrossRef]
  168. Charalambides, P.; Lund, J.; Evans, A.; McMeeking, R. A Test Specimen for Determining the Fracture Resistance of Bimaterial Interfaces. J. Appl. Mech. 1989, 56, 77–82. [Google Scholar] [CrossRef]
  169. Sexsmith, M.; Troczynski, T. Peel strength of thermal sprayed coatings. J. Therm. Spray Technol. 1996, 5, 196–206. [Google Scholar] [CrossRef]
  170. Nase, M.; Zankel, A.; Langer, B.; Baumann, H.J.; Grellmann, W.; Poelt, P. Investigation of the peel behavior of polyethylene/polybutene-1 peel films using in situ peel tests with environmental scanning electron microscopy. Polymer 2008, 49, 5458–5466. [Google Scholar] [CrossRef]
  171. Kurzweg, H.; Heimann, R.B.; Troczynski, T. Adhesion of thermally sprayed hydroxyapatite–bond-coat systems measured by a novel peel test. J. Mater. Sci. Mater. Electron. 1998, 9, 9–16. [Google Scholar] [CrossRef]
  172. Mahltig, B. 10—Smart hydrophobic and soil-repellent protective composite coatings for textiles and leather. In Smart Composite Coatings and Membranes; Montemor, M.F., Ed.; Woodhead Publishing: Cambridge, UK, 2016; pp. 261–292. [Google Scholar]
  173. Guy, O.J.; Walker, K.-A.D. Chapter 4—Graphene Functionalization for Biosensor Applications. In Silicon Carbide Biotechnology, 2nd ed.; Saddow, S.E., Ed.; Elsevier: Amsterdam, The Netherlands, 2016; pp. 85–141. [Google Scholar]
  174. Sreekumar, P.A.; Thomas, S. 2—Matrices for natural-fibre reinforced composites. In Properties and Performance of Natural-Fibre Composites; Pickering, K.L., Ed.; Woodhead Publishing: Cambridge, UK, 2008; pp. 67–126. [Google Scholar]
  175. Fujii, H.; Matsumoto, T.; Izutani, S.; Kiguchi, S.; Nogi, K. Surface tension of molten silicon measured by microgravity oscillating drop method and improved sessile drop method. Acta Mater. 2006, 54, 1221–1225. [Google Scholar] [CrossRef]
  176. Xue, J.; Shi, P.; Zhu, L.; Ding, J.; Chen, Q.; Wang, Q. A modified captive bubble method for determining advancing and receding contact angles. Appl. Surf. Sci. 2014, 296, 133–139. [Google Scholar] [CrossRef]
  177. Ramé, E. The Interpretation of Dynamic Contact Angles Measured by the Wilhelmy Plate Method. J. Colloid Interface Sci. 1997, 185, 245–251. [Google Scholar] [CrossRef]
  178. Yan, Y.; Neville, A. Bio-tribocorrosion: Surface interactions in total joint replacement (TJR). In Bio-Tribocorrosion in Biomaterials and Medical Implants; Yan, Y., Ed.; Woodhead Publishing: Cambridge, UK, 2013; pp. 309–340. [Google Scholar]
  179. Kohli, R. Chapter 3—Methods for Monitoring and Measuring Cleanliness of Surfaces. In Developments in Surface Contamination and Cleaning; Kohli, R., Mittal, K.L., Eds.; William Andrew Publishing: Oxford, UK, 2012; pp. 107–178. [Google Scholar]
  180. Prodana, M.; Nistor, C.-E.; Stoian, A.B.; Ionita, D.; Burnei, C. Dual Nanofibrous Bioactive Coatings on TiZr Implants. Coatings 2020, 10, 526. [Google Scholar] [CrossRef]
  181. Avcu, E.; Yıldıran Avcu, Y.; Baştan, F.E.; Rehman, M.A.U.; Üstel, F.; Boccaccini, A.R. Tailoring the surface characteristics of electrophoretically deposited chitosan-based bioactive glass composite coatings on titanium implants via grit blasting. Prog. Org. Coat. 2018, 123, 362–373. [Google Scholar] [CrossRef]
  182. Spriano, S.; Chandra, V.S.; Cochis, A.; Uberti, F.; Rimondini, L.; Bertone, E.; Vitale, A.; Scolaro, C.; Ferrari, M.; Cirisano, F.; et al. How do wettability, zeta potential and hydroxylation degree affect the biological response of biomaterials? Mater. Sci. Eng. C 2017, 74, 542–555. [Google Scholar] [CrossRef]
  183. Li, L.; Li, L.H.; Ramakrishnan, S.; Dai, X.J.; Nicholas, K.; Chen, Y.; Chen, Z.; Liu, X. Controlling Wettability of Boron Nitride Nanotube Films and Improved Cell Proliferation. J. Phys. Chem. C 2012, 116, 18334–18339. [Google Scholar] [CrossRef]
  184. Gittens, R.A.; Scheideler, L.; Rupp, F.; Hyzy, S.L.; Geis-Gerstorfer, J.; Schwartz, Z.; Boyan, B.D. A review on the wettability of dental implant surfaces II: Biological and clinical aspects. Acta Biomater. 2014, 10, 2907–2918. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  185. Chen, Q.; Cabanas-Polo, S.; Goudouri, O.-M.; Boccaccini, A.R. Electrophoretic co-deposition of polyvinyl alcohol (PVA) reinforced alginate–Bioglass® composite coating on stainless steel: Mechanical properties and in-vitro bioactivity assessment. Mater. Sci. Eng. C 2014, 40, 55–64. [Google Scholar] [CrossRef]
  186. Gebhardt, F.; Seuss, S.; Turhan, M.C.; Hornberger, H.; Virtanen, S.; Boccaccini, A.R. Characterization of electrophoretic chitosan coatings on stainless steel. Mater. Lett. 2012, 66, 302–304. [Google Scholar] [CrossRef]
  187. Menzies, K.L.; Jones, L. The Impact of Contact Angle on the Biocompatibility of Biomaterials. Optom. Vis. Sci. 2010, 87, 387–399. [Google Scholar] [CrossRef] [PubMed]
  188. Khoury, J.; Kirkpatrick, S.R.; Maxwell, M.; Cherian, R.E.; Kirkpatrick, A.; Svrluga, R.C. Neutral atom beam technique enhances bioactivity of PEEK. Nucl. Instrum. Methods Phys. Res. Sect. B 2013, 307, 630–634. [Google Scholar] [CrossRef]
  189. Cordero-Arias, L.; Cabanas-Polo, S.; Gao, H.; Gilabert, J.; Sanchez, E.; Roether, J.; Schubert, D.; Virtanen, S.; Boccaccini, A.R. Electrophoretic deposition of nanostructured-TiO2/chitosan composite coatings on stainless steel. RSC Adv. 2013, 3, 11247–11254. [Google Scholar] [CrossRef] [Green Version]
  190. Usinskas, P.; Stankeviciute, Z.; Beganskiene, A.; Kareiva, A. Sol-gel derived porous and hydrophilic calcium hydroxyapatite coating on modified titanium substrate. Surf. Coat. Technol. 2016, 307, 935–940. [Google Scholar] [CrossRef]
  191. Mahlooji, E.; Atapour, M.; Labbaf, S. Electrophoretic deposition of Bioactive glass—Chitosan nanocomposite coatings on Ti-6Al-4V for orthopedic applications. Carbohydr. Polym. 2019, 226, 115299. [Google Scholar] [CrossRef]
  192. Kiran, A.S.K.; Kumar, T.S.S.; Sanghavi, R.; Doble, M.; Ramakrishna, S. Antibacterial and Bioactive Surface Modifications of Titanium Implants by PCL/TiO2 Nanocomposite Coatings. Nanomaterials 2018, 8, 860. [Google Scholar] [CrossRef] [Green Version]
  193. Wang, L.; Zhang, L.; Yan, J.; Yin, Z.; Tang, C.; Guo, Y.; Li, D.; Wei, B.; Xu, Y.; Gu, Q. Electrospun vancomycin-loaded coating on titanium implants for the prevention of implant-associated infections. Int. J. Nanomed. 2014, 9, 3027–3036. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  194. Popat, K.C.; Eltgroth, M.; LaTempa, T.J.; Grimes, C.A.; Desai, T.A. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes. Biomaterials 2007, 28, 4880–4888. [Google Scholar] [CrossRef]
  195. Lyndon, J.A.; Boyd, B.J.; Birbilis, N. Metallic implant drug/device combinations for controlled drug release in orthopaedic applications. J. Control. Release 2014, 179, 63–75. [Google Scholar] [CrossRef]
  196. Langer, R.; Peppas, N. Chemical and Physical Structure of Polymers as Carriers for Controlled Release of Bioactive Agents: A Review. J. Macromol. Sci. Part C 1983, 23, 61–126. [Google Scholar] [CrossRef]
  197. Zhang, L.; Yu, D.; Regenstein, J.M.; Xia, W.; Dong, J. A comprehensive review on natural bioactive films with controlled release characteristics and their applications in foods and pharmaceuticals. Trends Food Sci. Technol. 2021, 112, 690–707. [Google Scholar] [CrossRef]
  198. Siepmann, J.; Siegel, R.A.; Siepmann, F. Diffusion Controlled Drug Delivery Systems. In Fundamentals and Applications of Controlled Release Drug Delivery; Siepmann, J., Siegel, R.A., Rathbone, M.J., Eds.; Springer: Boston, MA, USA, 2012; pp. 127–152. [Google Scholar]
  199. Srikonda, S.; Kotamraj, P.; Barclay, B. Osmotic controlled drug delivery systems. In Design of Controlled Release Drug Delivery Systems; McGraw-Hill: New York, NY, USA, 2006; p. 203. [Google Scholar]
  200. Sahoo, C.K.; Sahoo, N.K.; Rao, S.R.M.; Sudhakar, M.; Satyanarayana, K. A review on controlled porosity osmotic pump tablets and its evaluation. Bull. Fac. Pharm. Cairo Univ. 2015, 53, 195–205. [Google Scholar] [CrossRef] [Green Version]
  201. Danckwerts, M.; Fassihi, A. Implantable Controlled Release Drug Delivery Systems: A Review. Drug Dev. Ind. Pharm. 1991, 17, 1465–1502. [Google Scholar] [CrossRef]
  202. Kastellorizios, M.; Burgess, D.J. In vitro drug release testing and in vivo/in vitro correlation for long acting implants and injections. In Long Acting Injections and Implants; Springer: Boston, MA, USA, 2012; pp. 475–503. [Google Scholar]
  203. Bhowmick, M.; Tamizharasi Sengodan, D.; Thangavel, S. Evaluation and characterization of transdermal therapeutic systems: An exhaustive pictorial and figurative review. J. Drug Deliv. Ther. 2014, 4, 9–22. [Google Scholar] [CrossRef]
  204. D’Souza, S.S.; DeLuca, P.P. Methods to Assess in vitro Drug Release from Injectable Polymeric Particulate Systems. Pharm. Res. 2006, 23, 460–474. [Google Scholar] [CrossRef]
  205. Singhvi, G.; Singh, M. In-vitro drug release characterization models. Int. J. Pharm. Stud. Res. 2011, 2, 77–84. [Google Scholar]
  206. Nur, A.O.; Zhang, J.S. Captopril Floating and/or Bioadhesive Tablets: Design and Release Kinetics. Drug Dev. Ind. Pharm. 2000, 26, 965–969. [Google Scholar] [CrossRef] [PubMed]
  207. Dash, S.; Murthy, P.N.; Nath, L.; Chowdhury, P. Kinetic modeling on drug release from controlled drug delivery systems. Acta Pol. Pharm. 2010, 67, 217–223. [Google Scholar] [PubMed]
  208. Costa, P.; Sousa Lobo, J.M. Modeling and comparison of dissolution profiles. Eur. J. Pharm. Sci. 2001, 13, 123–133. [Google Scholar] [CrossRef]
  209. Li, Z.; Mei, S.; Dong, Y.; She, F.; Li, Y.; Li, P.; Kong, L. Functional Nanofibrous Biomaterials of Tailored Structures for Drug Delivery—A Critical Review. Pharmaceutics 2020, 12, 522. [Google Scholar] [CrossRef]
  210. Stigter, M.; Bezemer, J.; de Groot, K.; Layrolle, P. Incorporation of different antibiotics into carbonated hydroxyapatite coatings on titanium implants, release and antibiotic efficacy. J. Control. Release 2004, 99, 127–137. [Google Scholar] [CrossRef] [PubMed]
  211. Mu, C.; Hu, Y.; Huang, L.; Shen, X.; Li, M.; Li, L.; Gu, H.; Yu, Y.; Xia, Z.; Cai, K. Sustained raloxifene release from hyaluronan-alendronate-functionalized titanium nanotube arrays capable of enhancing osseointegration in osteoporotic rabbits. Mater. Sci. Eng. C 2018, 82, 345–353. [Google Scholar] [CrossRef] [PubMed]
  212. Barik, A.; Chakravorty, N. Targeted Drug Delivery from Titanium Implants: A Review of Challenges and Approaches. In Advances in Experimental Medicine and Biology; Springer: Cham, Switzerland, 2019; pp. 1–17. [Google Scholar]
  213. Gulati, K.; Kant, K.; Findlay, D.; Losic, D. Periodically tailored titania nanotubes for enhanced drug loading and releasing performances. J. Mater. Chem. B 2015, 3, 2553–2559. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  214. Goudarzi, A.; Sadrnezhaad, S.K.; Johari, N. The prominent role of fully-controlled surface co-modification procedure using titanium nanotubes and silk fibroin nanofibers in the performance enhancement of Ti6Al4V implants. Surf. Coat. Technol. 2021, 412, 127001. [Google Scholar] [CrossRef]
  215. Wei, P.; Wang, B.; Lu, X.; Xin, R.; Ren, F. Bio-inspired immobilization of strontium substituted hydroxyapatite nanocrystals and alendronate on the surface of AZ31 magnesium alloy for osteoporotic fracture repair. Surf. Coat. Technol. 2017, 313, 381–390. [Google Scholar] [CrossRef]
  216. Gulati, K.; Aw, M.S.; Findlay, D.; Losic, D. Local drug delivery to the bone by drug-releasing implants: Perspectives of nano-engineered titania nanotube arrays. Ther. Deliv. 2012, 3, 857–873. [Google Scholar] [CrossRef] [PubMed]
Figure 1. ToF-SIMS mapping of the coating on AISI 316LVM (a,c) and TiAlV (b,d) performed by summarizing positive ions at m/z 339.99 and 341.99 (a,b) and negative ion sat m/z 26.00 for CN (c,d) [57]. Reprinted from Progress in Organic Coatings, 158, Finšgar et al., The development and characterization of bioactive coatings for local drug delivery in orthopedic applications, Copyright (2021), with permission from Elsevier.
Figure 1. ToF-SIMS mapping of the coating on AISI 316LVM (a,c) and TiAlV (b,d) performed by summarizing positive ions at m/z 339.99 and 341.99 (a,b) and negative ion sat m/z 26.00 for CN (c,d) [57]. Reprinted from Progress in Organic Coatings, 158, Finšgar et al., The development and characterization of bioactive coatings for local drug delivery in orthopedic applications, Copyright (2021), with permission from Elsevier.
Biomedicines 09 01936 g001
Figure 2. IR radiation path in the ATR-FTIR system [81]. Reprinted from Biochimica et Biophysica Acta (BBA)—Biomembranes, 1828, Yechiel Shai, ATR-FTIR studies in pore forming and membrane induced fusion peptides, 2306–2313, Copyright (2013), with permission from Elsevier.
Figure 2. IR radiation path in the ATR-FTIR system [81]. Reprinted from Biochimica et Biophysica Acta (BBA)—Biomembranes, 1828, Yechiel Shai, ATR-FTIR studies in pore forming and membrane induced fusion peptides, 2306–2313, Copyright (2013), with permission from Elsevier.
Biomedicines 09 01936 g002
Figure 3. Micro-CT images of the transverse sections with a radius of 1 mm from implant surface of a canine femur 12 weeks after the implantation of bare Ti alloy, HA-, HT-, and Sr-HT-coated implants [138]. Reprinted from Biomaterials, 34, Zhang et al., The synergistic effect of hierarchical micro/nano-topography and bioactive ions for enhanced osseointegration, 3184-3195, Copyright (2013), with permission from Elsevier.
Figure 3. Micro-CT images of the transverse sections with a radius of 1 mm from implant surface of a canine femur 12 weeks after the implantation of bare Ti alloy, HA-, HT-, and Sr-HT-coated implants [138]. Reprinted from Biomaterials, 34, Zhang et al., The synergistic effect of hierarchical micro/nano-topography and bioactive ions for enhanced osseointegration, 3184-3195, Copyright (2013), with permission from Elsevier.
Biomedicines 09 01936 g003
Figure 4. A schematic representation of potential biological interactions with (A) hydrophilic and (B) hydrophobic surfaces. (A) hydrophilic surfaces interact with biological fluids, allow adsorption of proteins to the material surface, and facilitate interaction with cell receptors. (B) hydrophobic surfaces generally contain hydrocarbon contamination and consequently entrap air bubbles that inhibit protein adsorption and cell receptor activation [184]. Reprinted from Acta Biomaterialia, 10, Gittens et al., A review on the wettability of dental implant surfaces II: Biological and clinical aspects, 2907-2918, Copyright (2014), with permission from Elsevier.
Figure 4. A schematic representation of potential biological interactions with (A) hydrophilic and (B) hydrophobic surfaces. (A) hydrophilic surfaces interact with biological fluids, allow adsorption of proteins to the material surface, and facilitate interaction with cell receptors. (B) hydrophobic surfaces generally contain hydrocarbon contamination and consequently entrap air bubbles that inhibit protein adsorption and cell receptor activation [184]. Reprinted from Acta Biomaterialia, 10, Gittens et al., A review on the wettability of dental implant surfaces II: Biological and clinical aspects, 2907-2918, Copyright (2014), with permission from Elsevier.
Biomedicines 09 01936 g004
Figure 5. In vitro drug dissolution process with USP apparatus type I (rotating basket).
Figure 5. In vitro drug dissolution process with USP apparatus type I (rotating basket).
Biomedicines 09 01936 g005
Figure 6. A triphasic drug release profile with a short second phase (red), a burst drug release profile (yellow), a burst release profile with zero-order (orange), a zero-order drug release profile (blue), a triphasic release profile (green), and a biphasic drug release profile (black). Reprinted with permission from [209].
Figure 6. A triphasic drug release profile with a short second phase (red), a burst drug release profile (yellow), a burst release profile with zero-order (orange), a zero-order drug release profile (blue), a triphasic release profile (green), and a biphasic drug release profile (black). Reprinted with permission from [209].
Biomedicines 09 01936 g006
Table 1. A list of the chemical structures of bioactive coatings as a function of wavenumbers (cm−1) obtained using FTIR/ATR-FTIR.
Table 1. A list of the chemical structures of bioactive coatings as a function of wavenumbers (cm−1) obtained using FTIR/ATR-FTIR.
Drug/Bioactive Coating MaterialFunctional GroupsWavenumber (cm−1)References
Drugs
ClindamycinN–C=O stretching1682 and 1550[32]
C–O stretching1038 and 1079
S–C–H bending1209 and 1249
DCFR–C=O stretching1305, 1500–1750[24,93]
R=C=O stretching1577
C–Cl stretching650–780
HC–N–CH bending1376
CH2 bending1462
VancomycinC–H3284[92]
RifampicinC–H2880[87,92]
OH−3480
furanone (C=O)1644
acetyl (C=O)1725
(C=O)1567
N–CH32878
EnrofloxacinC=O1731[85]
OH bending1631
COO–stretching1508
COO1477
DexamethasonP–O1041[86]
IbuprofenC=O stretching1720[89]
C=C of the phenyl ring1513
C–H1463 and 1378
Polymers
PCLasymmetric C=H stretching2939[87,94]
symmetric C=H stretching2864
C=O stretching1730
C–O/C–C stretching1294
asymmetric C–O–C stretching1240
asymmetric CH2 stretching2944 and 2865
Poly(lactic-co glycolic acid) (PLGA)C–H3000–2850[92]
CHIO–H3700–3000[34,82,93,95]
Amide NHCOCH31643 and 1540
NH2 stretching3430
NH stretching1654
CH scissoring1422–1380
CH stretching2920
C–O–C stretching900;
1015;
Poly(methyl methacrylate) (PMMA)C–O–C symmetric stretching1149[88]
CH2 bending1439
C=O stretching1721
asymmetric CH3 stretching2951
Polyvinyl alcohol (PVA)OH stretching3520[34]
OH bending1440
asymmetric CH2 stretching2910
C–O stretching1067
C=O stretching1740
Alginatesymmetric COO−stretching1620 and 1413[96]
COOH stretching1723
Carboxymethyl cellulose (CMC)Carboxylate group1630[32]
O–H3200–3400
C–OH stretching1000–1250[24]
C–O–C bending
PolydopamineOH stretching3348[86]
NH stretching3176
Other bioactive materials
HAPO43−956, 1055, and 1101;
567, 603, and 1032;
[39,67,69]
CO23−854, 1410
OH3484
BGSi–O–Si bending450[82,88]
Si–O–Si stretching930;
1030;
P–O stretching1015
TNTsTi–O480;
696
[85,97]
TiO–H3396
Ti-O-Ti540
TiO2Ti–O800[88]
Single-walled carbon nanotubesC–O1112[67]
C–C1630
C=O1730
O–H3440
Table 2. AFM measurements of bioactive coatings on metallic substrates.
Table 2. AFM measurements of bioactive coatings on metallic substrates.
Coating Deposition TechniqueImplant and Coating MaterialsAFM SpecificationsInformation ObtainedReferences
AnodizationTi substrate, TNT coatingsTapping mode, tapping cantilever tips (NSC15/NoAl), a scanning size of 1.0 µm2Higher surface roughness compared to bare substrate, which contributes to an increase in the osteoblast adhesion and osseointegration of the implant material[101]
Layer-by-layerTi6Al4V alloy and AISI316LVM substrates, poly(2-hydroxyethyl methacrylate) (PHEMA), poly(2-hydroxypropylmethacrylate) (PHPMA), and sodium deoxycholate (NaDOC) coatings containing the anti-inflammatory drug DCFAcoustic mode, in air at 25 °C, a scanning size of 1 × 1 µm2The coatings are structured in a particle-like form in the case of a polymer layer in the uppermost position, low values of roughness parameters with a decrease in scan size indicate flat morphologies on the substrate and very smooth coating layers[57]
AISI316LVM substrate, CHI and DCF coating layersTapping mode at room temperature, a sample size of 5 × 5 μm2, a resolution of 2048 × 2048 pixels, silicon cantilevers with a resonance frequency of 210–490 kHz, and a force constant of 12–110 N m−1Smaller and thinner surface interconnects in the case of a polymer layer in the uppermost position[93]
AISI316LVM substrate, CMC and DCF coating layersAcoustic mode with scan sizes of 10 × 10, 5 × 5, and 1 × 1 μm2, a resolution of at least 512 × 512 pixels, silicon cantilevers with a resonance frequency of 210–490 kHz and a force constant of 12–110 N m−1All samples showed similar results regarding topography, with substrate lines visible on all samples due to the grinding process, the roughness parameters slightly increased for the samples with the DCF layers on top[24]
Ti substrate, coatings of poly(acrylic acid) (PAA) and poly(l-lysine) (PLL), with beta cyclodextrin (β-CD) complexes used to retain tetracycline (TC)Peak-force tapping mode, silicon nitride cantilevers, a nominal spring constant of 0.7 N/m, and a scanning size of 2 × 2 mmSignificantly decreased values of roughness, suggesting that the incorporation of TC/anionic β-CD macromolecules smoothens the surface[102]
3D printing, electrospinning3D printing: Ti6Al4V and AISI 316LVM substrates,
coatings of cellulose nanofibril suspension, alginate, and CMC, loaded with clindamycin
Electrospinning: TiAlV and AISI 316LVM substrates, coatings of CMC and polyethylene oxide, loaded with clindamycin
Tapping mode, room temperature, silicon cantilevers, a resonance frequency of 210–490 kHz, a force constant of 12–110 N m−1, scanning sizes of 10 × 10 and 1 × 1 μm2, a resolution of 512 × 512 pixelsRelatively smooth surface of the noncoated coatings, functionalization with clindamycin showed no significant effect on the morphology and roughness of the samples, indicating a homogeneous distribution of the drug in the coating[32]
GraftingTi6Al4V substrate, coatings of polymers bearing sulfonate (styrene sodium sulfonate, NaSS) and carboxylate (methylacrylic acid, MA) groupsContact mode, NP-S tips, a scan rate of 3.3 Hz, two images per sample were acquired from 41 × 41 µm2 areas and flattened by first-order line flatteningIncreasing the oxidation treatment time from 1 to 3 min. resulted in a doubling of the surface roughness[60]
Drop castingTi substrate, CH/PVA coatingsTapping mode, a scanning size of 1 × 1 μm2, the images are first-order x–y plane fitted and then first-order flattened using Nanoscope software (v1.30)Nanometer-sized islands throughout the CH/PVA composite films, roughness, which promotes cell adhesion and proliferation, increased with the coating concentration[34]
Initiated chemical vapor deposition (iCVD)Ti substrate, coatings of rhBMP-2 immobilized on glycidyl methacrylate (GMA)A scanning area of 10 × 10 μm 2, room temperatureSmooth, bare, and pGMA-coated surface, a rough surface after functionalization with rhBMP-2[71]
Table 3. Kinetic models and their associated equations [205,207,208].
Table 3. Kinetic models and their associated equations [205,207,208].
Kinetic ModelsEquations
Zero-order d c d t = k (4)
where c represents the concentration, t represents time, and k represents the release rate constant.
First-order d c d t = k · c (5)
Higuchi f i = Q = D · 2 c t c s · c s · t , (6)
or a simplified Higuchi equation:
c t =   K H · t (7)
where Q represents the amount of released drug at a given time and area, c t represents the concentration at time t, cs represents the drug solubility in the media matrix, D represents the diffusion coefficient, and K H represents the Higuchi release rate constant.
Hixon–Crowell c 0 3 c t 3 = K HC · t (8)
where K HC represents the Hixon–Crowell release rate constant.
Korsmeyer–Peppas C t C = K · t n (9)
where c represents the equilibrium drug concentration, K represents the release rate constant, and n the release exponent.
Baker–Lonsdale 3 2 1 C t C 2 3 C t C = K · t (10)
Table 4. Coating-implant systems, the incorporated drugs, and the drug release characteristics.
Table 4. Coating-implant systems, the incorporated drugs, and the drug release characteristics.
SystemDrugDrug ReleaseReference
Electrospinning
PCL/HA nanoparticle composite coatings on AZ31 Mg alloySimvastatinInitial burst release controlled by diffusion (first day), followed by sustained release for up to 6 days controlled by polymer degradation[94]
PLGA on TiAspirinProlonged release:
early rapid release (50–60% in the first 2 weeks) followed by a slow release for up to 2 months
[108]
VancomycinBiphasic release pattern: initial burst release on day 1, followed by slow and controlled release for up to 28 days[193]
PCL/HA on TiRifampicinInitial burst release (40% in the first day), followed by sustained release for 32 days[87]
Electrophoretic deposition
CaP on Mg alloyZoledronateContinual gradient increase until 1 week[30]
CHI/BG on AISI 316LVMGentamicinInitial burst release in the first week, slow release for up to 56 days[41]
halloysite nanotubes/CHI/BG on AISI 315 LVMTetracycline hydrochlorideRapid release within the first 14 days (54% of the drug), followed by slower release for up to 42 days (73% of the drug)[114]
Electrophoretic deposition + sol-gel
CHI/mesoporous silica nanoparticles on TiIbuprofenPlateau within the first day[89]
Drop casting
CHI/amino-functionalized BG on TiVancomycinBurst release of 42% in the early stages, slow release for up to 14 days[20]
Dip coating
HA hydrogel on dental implants (Implantium, Dentum Co. Ltd., Suwon, Korea)rhBMP2Slow and sustained release for up to 35 days[40]
Sol-gel
HA/BMP2 on TiGentamicinRelease of more than 99% of gentamicin contained in the coating after 2 days[13]
Biomimetic deposition
HA on Ti6Al4VTobramycinInitial rapid release, followed by a plateau, 90% of the drug released within 180 min[36]
Carbonated HA on TiCephalothin, cefamandole, tobramycin and gentamicinRapid release: all of the gentamicin within 1 h, 80–90% of the cefamandole and tobramycin within 8 h, 70% of the cephalothin within 16 h[210]
LbL deposition
CMC on AISI 316LVMDCF1–10 min: burst release following the zero-order release mechanism, 10–30 min: fast release (60% of the drug is released by this point) following the Higuchi release mechanism, 30–360 min: slow release, Higuchi, 360–1440 min: the plateau[24]
CHI/gelatin on TiLevofloxacineGradual release for up to 4 days[106]
PAA/PLL/β-CDTetracyclineBurst release within the first day, continuous release over the next 15 days, plateau for up to 30 days[102]
Anodization (TNTs)
TNT/polydopamineDexamethasoneSlow release over a period of 75 h (maximum drug release is 84%)[86]
Periodically tailored TNTsIndomethacinA zero-order release mechanism, slow and steady release for up to 17 days (maximum drug release of 50%)[213]
(-NH2)- and (-SH)-treated TNTsEnrofloxacinHiguchi release mechanism, initial burst release for up to 7 h, followed by slower matrix-controlled release for up to 50 h[85]
1–10 layers of PLGA on TNTsIbuprofenProlonged and controlled release for up to 40 days with 10 layers of PLGA[37]
Silk fibroin on TNTsVancomycinHiguchi release mechanism, initial burst release on the first day (20% of drug released), followed by a slower release, but constant release for up to 40 days[214]
Alendronate-grafted HA on TNTsRaloxifeneSteady and sustained release until 92 h, release rate gradually decreasing from 92 h to 192 h[211]
Co-immobilization
Sr-HA nanocrystals co-immobilized on AZ31 Mg alloy with polydopamine and carboxymethyl CHIAlendronateInitial fast release of 25% of the drug within the first day, followed by slower release with 1–4% of the drug released per day for up to 14 days[215]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kravanja, K.A.; Finšgar, M. Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants. Biomedicines 2021, 9, 1936. https://doi.org/10.3390/biomedicines9121936

AMA Style

Kravanja KA, Finšgar M. Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants. Biomedicines. 2021; 9(12):1936. https://doi.org/10.3390/biomedicines9121936

Chicago/Turabian Style

Kravanja, Katja Andrina, and Matjaž Finšgar. 2021. "Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants" Biomedicines 9, no. 12: 1936. https://doi.org/10.3390/biomedicines9121936

APA Style

Kravanja, K. A., & Finšgar, M. (2021). Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants. Biomedicines, 9(12), 1936. https://doi.org/10.3390/biomedicines9121936

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop