Next Article in Journal
Nondestructive Thickness Measurement of Thermal Barrier Coatings for Turbine Blades by Terahertz Time Domain Spectroscopy
Previous Article in Journal
Thermal Sensitivity of Birefringence in Polarization-Maintaining Hollow-Core Photonic Bandgap Fibers
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Analysis and Suppression of Crosstalk Beams in Microlens Array Scanning Imaging Optical System Based on the Combination of Multilayer Stop Arrays

Key Laboratory of Optoelectronic Measurement and Optical Information Transmission Technology of Ministry of Education, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130012, China
*
Author to whom correspondence should be addressed.
Photonics 2023, 10(2), 104; https://doi.org/10.3390/photonics10020104
Submission received: 19 December 2022 / Revised: 9 January 2023 / Accepted: 16 January 2023 / Published: 19 January 2023

Abstract

:
The lateral displacement between the microlens arrays can realize the rapid deflection of a beam; however, in this process, crosstalk beams will inevitably occur between the microlens units, which will affect the imaging quality of the system. For this reason, we propose a crosstalk elimination design method based on the combination of multilayer stop arrays, establish a simulation model, use a geometric optical object image relationship to trace the characteristic light of a single group of microlenses, analyze the relationship between the structural parameters of the microlens array and the stop array size, and comprehensively discuss the light transmission of the microlens array under various conditions. An example of an infrared system is simulated using the optical design analysis software Fred, verifying the effectiveness of this design method in suppressing the crosstalk beams generated in the dynamic transmission process, ensuring independent propagation between microlens units, and realizing crosstalk-free imaging.

1. Introduction

Beam scanning technology refers to the technology of accurately controlling and positioning the beam direction, which is often used in the fields of laser radar, optical information processing, and free space optical communication. Beam scanning technology can be divided into mechanical scanning, micro-electromechanical scanning, and purely electronic, non-mechanical scanning. Today’s development trend is to focus on the research and development of a beam scanning system that integrates a large scanning angle, high precision, fast response, and high efficiency. At the same time, in order to facilitate integration and military and civilian applications, the system also needs to be more compact and flexible, and the manufacturing process needs to be simple. As for the current situation, the microlens array has the potential development space to achieve the above characteristics, with a small beam pointing deviation and a high scanning rate. In this paper, the method of beam scanning through the double-layer microlens array belongs to micro-electromechanical systems (MEMS) scanning [1]. Microlens arrays are widely used in the fields of optical imaging detection, laser radar, and optical communication, owing to their small beam-pointing deviation, high scanning rate, and fast steering during dynamic imaging [2,3,4], and the fabrication process of microlens arrays is gradually improving [5,6,7]. The lightweight and small motion characteristics of microlens arrays mean that, compared with macro lenses, they can greatly simplify mechanical parts to achieve beam steering. However, as the scanning angle increases, beam crosstalk can occur between microlens array units, that is, some light will be superimposed on the imaging light of adjacent units and will therefore participate in adjacent imaging, which interferes with normal light transmission; this is called a crosstalk beam, and its occurrence reduces the imaging contrast of an imaging system.
Many researchers have proposed a variety of solutions to the crosstalk problem in different situations. In 2004, researchers made an objective lens array and a collimating lens array on the same substrate, so that the first side of the second row could be used as a field mirror and the arrays could move in the same way to achieve crosstalk-free beam imaging. When scanning with visible light, a beam deflection of 3–7.4° and a transmission efficiency of up to 13% can be achieved compared with that of single-sided scanning [8]. In 2018, researchers at Tianjin University designed a transceiver microlens array system that used optical wedges to switch the field of view so that there was no crosstalk between the fields of view, and it was combined with the front and rear objective lenses to realize beam scanning with a scanning field angle of ±8° and an instantaneous field angle of ±1.06° [9,10]. In the same year, researchers at a laboratory in Beijing proposed a method of combining aperture and microlens arrays to eliminate crosstalk; they studied the instantaneous field of a microlens array at a limited object distance and achieved high-quality imaging [11]. The propagation path of stray light can also be blocked using a field aperture, a Lyot stop, and the ‘no-shelter’ optical design [12,13].
Aiming at the problem of crosstalk beam in the application of microlens array scanning imaging, focus on the research on the crosstalk influence mechanism of microlens array, combine the microlens array imaging theory, carry out the research on the influence of the crosstalk beam between arrays based on geometric optics and diffraction effect, and build the stray light analysis model. According to different situations, the size, filling ratio, and aperture of the microlens unit should be correctly selected, and the optimal relationship between the entrance pupil diameter and the exit pupil diameter of the microlens array unit should be studied to provide support for the stray light suppression and optimization design of the microlens array. In the past period of time, our team members have carried out research on some of these problems, such as proposing a filling factor to characterize the relative aperture and analyzing its impact on the modulation transfer function. The filling factor is calculated by matrix optical paraxial ray tracing using system parameters [14]. Based on the principle of minimum spherical aberration, the design method of the initial configuration of the MLA system is proposed, and the influence of the MLA system on detection range and imaging resolution is analyzed [15,16]. Aiming at the problem of obvious diffraction when light encounters small diameter components in the transmission process, the diffraction effect of microlens arrays is analyzed, and different types of aperture arrays with the same filling factor are given through geometric relationships and system parameters. The light intensity distribution forms are compared, the diffraction effect of aperture array forms on imaging quality is explored, and a more advantageous structural form is selected [17].
Due to the off-axis caused by the relative displacement of the double-layer microlens array in the process of movement and the discontinuous characteristic sampling of the array, the crosstalk beam of the microlens array system presents obvious nonlinear dynamic degradation characteristics with the increase in the search field of view, so it is necessary to study the mechanism and control methods of crosstalk beams. The existing micro-optical array imaging theory and optimization methods make it difficult to study the dynamic imaging characteristics of the stacked microlens array system. It is necessary to improve its dynamic imaging theory and modeling methods, improve the ability to control and suppress crosstalk during dynamic scanning, and break through the design method of the stacked microlens array for search imaging. In this paper, we refer to the research methods of other researchers and the work completed by the team members, combined with the above solutions, to consider the crosstalk problem when the dynamic scanning imaging object distance of a microlens array is infinite. Through analysis of the crosstalk mechanism, we propose a design of multilayer stop arrays combined to suppress crosstalk beams and consider an example scanning imaging system to verify the correctness of the proposed method, which provides a basis for crosstalk suppression design methods for other systems.

2. Crosstalk Beam Generation Mechanism

A microlens array is composed of lenses with small diameters arranged according to certain rules [18]. In this paper, we discuss a double-layer microlens array system; the field of view of this system is determined by both the instantaneous field of view (IFOV) and scanning field of view (SFOV). Hence, under the premise of ensuring maximum light energy utilization and to achieve a wider range of scanning, the first column of the microlens array is used for relative movement, and the second column and rear component are fixed. Beam deflection can be achieved by using the relative displacement of the two columns. Additionally, the rear focus of the first column coincides with the front focus of the second column; when the beam is incident on the system at an oblique parallel angle, the beam is emitted parallel to the optical axis through displacement, and different scanning angles correspond to different displacement Δ [19], as shown in Equation (1). IFOV and SFOV form the field of view of the microlens array system. As shown in Figure 1, fast scanning can be completed by using different fields of view of the system. The displacement of the system is given by
Δ = f × tan δ ,
where f is the focus of a single microlens, and δ is the scanning angle.
We define the width of the entrance pupil of the system as D E N , the width of the exit pupil of the system as D E X , radius of curvature of each lens surface as ( R 1 , R 2 , R 3 , R 4 ), thickness of each lens center as ( t d 1 ,   t d 2 ), refractive index of each lens as ( n 1 ,     n 2 ), and lens diameter as D L , the distance between the entrance pupil and the first surface as t 1 , the distance between the second surface and the primary image plane as t 2 , the distance between the primary image plane and the third surface as t 3 , and back intercept as t 4 .
However, the scanning process of the optical system has a large eccentricity or large angle of incidence. Figure 2 shows a schematic of the crosstalk generated by the proposed double-layer microlens array, based on the Kepler structure. At this time, not all incident light refracted by the first column micro lens array will enter the lens unit corresponding to the second column micro lens array, however, part of the light will continue to propagate to the adjacent lens, interfering with the normal imaging beam; this is defined as a crosstalk beam. The area D E N is an imaging ray. After system imaging, this area is D E X . The ray from the lower edge of D E X to the lower edge of the lens represents a non-imaging ray that remains in the corresponding array aperture. When the incidence angle of the ray changes, the non-imaging light can be converted to a crosstalk ray.

3. Crosstalk Suppression Design of Multilayer Stop Arrays Combination

Based on the discussion of the mechanism of crosstalk generation in Section 2, we propose a design method of a combination of multilayer stop arrays to eliminate crosstalk. In the process of light transmission, we can effectively isolate the crosstalk beam by reasonably setting the stop form.
We consider three aspects. First, a microlens array system is usually combined with an infrared optical system for imaging. The microlens array system has an aperture stop array at the exit pupil, which is where the imaging beam exits the system, as shown in Figure 3; additionally, the aperture stop array prevents the light in the non-imaging area from spreading to the image plane, effectively isolating the non-imaging beam.
Second, a crosstalk beam enters the image plane through the exit pupil, which interferes with the imaging of normal light and reduces the contrast of the image. If the energy of the crosstalk beam is too large, it can make it difficult to distinguish between the target and background and, therefore, difficult to extract useful information. Therefore, we set the first crosstalk suppression stop array at a certain distance from the front surface of the second column of the microlens array to limit the crosstalk beam during light transmission and effectively block stray light, as shown in Figure 3.
Finally, as the array scanning imaging system has an IFOV, the two columns of the microlens arrays form a focus-free system; the back focus surface of the first column of lenses is used as the front focus surface of the second column of lenses. Therefore, a second crosstalk suppression stop array is necessary at the primary image plane between the two arrays to control the number of imaging rays under multiple fields of view and limit the mixing of light outside the field of view. The light transmission is controlled by adjusting the position and size of this array.
To summarize, the aperture stop array and the two crosstalk suppression stop arrays form a multilayer stop array to realize crosstalk elimination. Through multilayer suppression, beams reaching the image plane can avoid interference from crosstalk beams and achieve high-precision imaging.

4. Parameter Calculation of Multilayer Stop Arrays

As shown in Figure 3, our initial structure is composed of two positive power microlenses; this is used as a model for analysis and discussion in this paper. To determine the specific location and aperture size of the crosstalk suppression stop arrays, calculations must consider ray tracing in geometric optics and the relevant theory of the Gaussian formula. According to these parameters, the exit pupil D E X can be calculated using the Lagrange invariant in Equation (2):
J = n u y = n u y ,
D E N = θ θ D E X
According to the theory of geometrical optics, the distance t 2 and t 3 can be determined using a Gaussian equation for the two lenses; hence, the position of the crosstalk suppression stop array 2, between the double-layer microlens arrays, can be determined by
n l n l = n n R ,
where n and n are the refractive indexes of each medium, l and l are the object and image distances, respectively, and R is the radius of curvature of the lens surface.
By calculating t 2 and t 3 (Figure 3), we obtain
t 2 = 1 n 1 × n 1 1 n 1 × R 1 t d 1 n 1 1 + 1 n 1 R 2 ,
t 3 = 1 n 2 × n 2 1 n 2 × R 4 t d 2 n 2 1 + 1 n 2 R 3 .
After determining the position of the crosstalk suppression stop array 2, reverse ray tracing is performed on the edge ray of the optical system that is incident at a non-zero field of view. As shown in Figure 4, the oblique parallel light enters the microlens array at an angle of θ and exits at an angle of θ . Therefore, the aperture sizes of both crosstalk suppression stops can be calculated by tracing the reverse optical path, according to IFOV, to ensure that no stray light leaks into the normal imaging optical path.
Expressions of each part of the refracted light ray in Figure 4 can be obtained:
tan θ = M N / 2 D E X / 2 t 4 + D D ,
D D = R 4 R 4 2 M N / 2 2 ,
3 = cos 1 M N 2 R 4 ,
1 = 180 ° 90 ° θ 3 .
Equation (11) can be obtained according to the refraction law
sin 1 = n 2 sin 2 .
We define the distance between the crosstalk suppression stop 1 and the front surface of the second row of the microlens array as t; then, the above steps are repeated to calculate the aperture size of the crosstalk suppression stop 1, which is given by Equation (12):
B 1 B 2 = E F 2 t + C C tan 180 ° 6 7 .
Similarly, the aperture size of the crosstalk suppression stop 2 is given by Equation (13):
A 1 A 2 = E F 2 t 3 + C C tan 180 ° 6 7 .
The size and position of each stop array can be approximated by the above method of reverse tracking the edge light, which provides theoretical support for our design of light elimination. As the above calculations are carried out without considering aberration, an appropriate allowance should be made for the size of the optical aperture to ensure that light can be stably transmitted between the corresponding microlens array units and stray light is prevented from entering the adjacent microlens units to ensure that the incident light can participate in the imaging to a greater extent during system simulation and actual design.

5. Case Analysis

We consider an example microlens array scanning imaging system to explain the theoretical aspects outlined in Section 2, Section 3 and Section 4. Table 1 details the parameters of the system.
Figure 5 shows a microlens array scanning imaging system that works in the mid-infrared band, and it was built using the optical software Fred to trace a small amount of light and simulate the above parameters. Two rows of 9 × 9 rectangle microlens arrays made of germanium are arranged. Scanning imaging is achieved through the relative displacement between the arrays. However, the crosstalk beam generated by the system during the scanning process interferes with the normal imaging optical path. As an example, we use Fred to simulate the crosstalk phenomenon of the microlens array with only an aperture stop array and no crosstalk suppression stop arrays when the microlens array is staggered along the Y axis and SFOV δ is −2°, IFOV θ is 0° and ±0.5°, as shown in Figure 5.
As the array is a periodic structure, the generated crosstalk beams also exit in a periodic and parallel manner, passing through the exit pupil and shining on the image plane, interfering with the normal imaging beam and causing image points to be overlapped and difficult to distinguish. Figure 6 shows images on the plane corresponding to different IFOV θ values when the same SFOV δ is −2°.
At the same time, since the microlens array is a two-dimensional dynamic scanning in device the working process, the crosstalk beam can affect the normal beam of the aperture at different positions. Figure 7 shows imaging diagrams under four characteristic situations when the microlens array is relatively displaced along the X or Y axis.
We take Figure 7a as an example, and get the energy of each aperture by advanced ray tracing with Fred, as shown in Table 2.
From the comprehensive consideration of the data in Table 2 and Figure 7a, it can be seen that the data in the first two rows in Table 2 is significantly higher than that in other rows because of the crosstalk beam. When the amount of simulation light increases, the image points of an increased number of crosstalk light beams will be alternately arranged with the image points from the imaging light beams on the image plane and distributed in multiple positions on the image plane, affecting the contrast. Therefore, the crosstalk suppression stop array 1 should be placed on the front surface of the second column of the microlens array to eliminate crosstalk at the design level and block the propagation path of the crosstalk beams.
The previous discussion about the light transmission was for SFOV δ was −2° and IFOV θ was 0° and ±0.5°. So as not to change the system structure or parameters, we only adjust the light incidence angle to −4°, keep δ at −2°, and increase θ to −2°. The results when the simulation lens is completely transmitted are shown in Figure 8. The crosstalk suppression stop array 2 effectively blocks light from outside the field of view. For the reason that the aperture size of the crosstalk suppression stop array 2 is calculated according to IFOV, which restricts the incident angle of light together with SFOV, it means that when the light source is incident at multiple angles, and the values of some of the incident angles are not within the limited range, the crosstalk suppression stop array 2 will block them, preventing light from outside the field of view from leaking into the normal imaging optical path.
At the same time, because the microlens arrays are not fully transmissive, ghost reflections occur on the surface of the lenses, and stray light from outside the field of view is generated from all angles. The crosstalk suppression stop array 2 will also block such stray light to prevent it from entering the subsequent optical path and affecting the imaging.
Combined with the above theory, multilayer stop arrays are added to the system to re-simulate it. The results are shown in Figure 9 and Table 3.
The image in the top line of Figure 9d is caused by the light source being directly incident on the system. Compared with Figure 6c, the system in Figure 9d has no crosstalk beams, and the power values of each aperture in Table 3 are uniformly distributed.
Therefore, the power value of the crosstalk beams interfering with the first and second row aperture stop arrays can be given according to the data in Table 2 and Table 3, as shown in Figure 10.
Similarly, through simulation and calculation, the crosstalk power under “Y axis, δ = −2°, θ = 0°” and “Y axis, δ = −2°, θ = 0.5°” can be given, as shown in Figure 11.
After adding the crosstalk suppression stop arrays, the crosstalk beam is blocked and will not appear on the image plane. The crosstalk-free imaging of the microlens array system with a SFOV of 4° × 4° and an IFOV of 1° × 1° is realized without an external lens.
We use the optical simulation software Fred to analyze the tolerance of crosstalk suppression stop arrays 1 and 2 in the system. The positioning tolerance is shown in Table 4.
As shown in Table 4, it is the positioning tolerance of two crosstalk suppression stop arrays on different optical axes. Since two-stop arrays correspond to different positions and parameters, their allowable variations on the reference position are also different.
Generally, the microlens array is connected to the actual imaging system. Therefore, according to Figure 9a, we add the actual imaging system behind the aperture stop array, as shown in Figure 12.
According to the optical system of Figure 12, Table 5 shows the imaging conditions for different values of SFOVand IFOV.
Figures in Table 5 correspond to different SFOVs and IFOVs, and the RMS size is within one pixel, so its aberration is acceptable. At the same time, because the system needs to perform dynamic scanning and imaging in the infrared band, it is difficult to achieve perfect imaging in the full medium wave section. However, for this system, we have expanded the wavelength by 3.8–4.2 μm, and its images are shown in Table 6, where the red color is 3.8μm, the blue color is 4.0 μm, and the green color is 4.2 μm.
It can be seen from Table 6 that, on the premise of considering both imaging results and beam scanning, the 3.8–4.2 μm wave band light is imaged through the system for non-crosstalk imaging, and all sizes of the image point are smaller than one pixel size, and the aberration is acceptable.
In summary, in the simulation of an actual optical system, multiple stop arrays can be used to cooperate with one another to suppress crosstalk beams layer by layer, maximizing the isolation of crosstalk beams in the system. Compared with the single-layer stop array suppression method, the proposed multilayer stop array crosstalk elimination design method improves the suppression of crosstalk beams and effectively suppresses other stray light, such as ghost reflection light.

6. Conclusions

To address the problem of array scanning and imaging optical systems generating crosstalk beams in the process of scanning and imaging, we analyzed the mechanism of crosstalk beams according to the relevant optical theory research, proposed a crosstalk elimination design method based on multilayer stop arrays to trace and investigate the ray in the dynamic scanning process of a microlens array, and determined the form of the stop array using geometric optics. To verify the ability of the multilayer stop array method to suppress crosstalk beams, we used the software Fred to simulate the transmission of an infrared microlens array system during dynamic scanning under different conditions and solve the crosstalk problem in the dynamic scanning process, providing support for stray light suppression and enabling us to determine the optimal design of the microlens array.

Author Contributions

Conceptualization, Z.L. (Zhiyang Lv) and Z.L. (Zhiying Liu); methodology, Z.L. (Zhiyang Lv) and Z.L. (Zhiying Liu); software, Z.L.(Zhiyang Lv) and Y.H.; validation, Z.L. (Zhiyang Lv), Y.H. and Z.L. (Zhiying Liu); formal analysis, Z.L. (Zhiyang Lv), Y.H. and Z.L. (Zhiying Liu); investigation, Z.L. (Zhiyang Lv), Y.H. and Z.L. (Zhiying Liu); resources, Z.L. (Zhiying Liu); data curation, Z.L. (Zhiyang Lv); writing—original draft preparation, Z.L. (Zhiyang Lv); writing—review and editing, Z.L. (Zhiying Liu); visualization, Z.L. (Zhiyang Lv); supervision, Z.L. (Zhiying Liu); project administration, Z.L. (Zhiying Liu); funding acquisition, Z.L. (Zhiying Liu). All authors have read and agreed to the published version of the manuscript.

Funding

National Natural Science Foundation of China (61805025), Jilin Scientific and Technological Development Program (20200401055GX).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Acknowledgments

The authors express their sincere thanks to National Demonstration Center for Experimental Opto-Electronic Engineering Educations for the support on the experiments.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Yan, Z.; Xu, J. Research development of beam scanning technology. Electro-Opt. Technol. Appl. 2013, 28, 1–9. [Google Scholar]
  2. Du, C.; Qiu, C.; Deng, Q.; Pan, L.; Bai, L.; Wang, Y. Study on the integrated chip of microlens array with IR detector array. Opto Electron. Eng. 2003, 30, 1–4. [Google Scholar]
  3. Gordan, N.T.; Jones, C.L.; Purdy, D.J. Application of microlens in the infrared detector array. J. Electron. Devices 1992, 15, 250–254. [Google Scholar]
  4. Xu, C.; Jin, W.; Li, Y. Optical microscanner technique and realization. Infrared Technol. 2006, 28, 338–342. [Google Scholar]
  5. Li, J.; Chu, C.; Lu, W.; Zhang, P.; Yang, G.; Zhong, H.; Zhao, Y. Develpopment of microlens arrays: From fabrication to photonic applications. Acta Photonica Sin. 2021, 41, 9–32. [Google Scholar]
  6. Liu, F.; Zhang, F.; Bian, H.; Yang, Q.; Li, M.; Chen, F. Development and preparation of refractive infrared microlens array device. Laser Optoelectron. Prog. 2020, 57, 071607. [Google Scholar]
  7. Yang, X.; Sun, H.; Yue, D.; Sun, J. Research progress of femtosecond laser fabrication of microlens array. Laser Optoelectron. Prog. 2021, 58, 050005. [Google Scholar]
  8. Duparré, J.; Radtke, D.; Dannberg, P. Implementation of field lens arrays in beam-deflecting microlens array telescopes. Appl. Opt. 2004, 43, 4854–4861. [Google Scholar] [CrossRef] [PubMed]
  9. Wang, Y. Application Research of Micro-Lens Array in Scanning Optical System. Ph.D. Thesis, Tianjin University, Tianjin, China, 2018. [Google Scholar]
  10. Xie, H.; Wang, Y.; Mao, C.; Su, Y.; Yang, L. Micro-lens array for integrative transmitting and receiving continuous scanning. J Appl. Opt. 2018, 39, 613–618. [Google Scholar]
  11. Chen, X.; Song, Y.; Zhang, W.; Sulaman, M.; Zhao, S.; Guo, B.; Hao, Q.; Li, L. Imaging method based on the combination of microlens arrays and aperture arrays. Appl. Opt. 2018, 57, 5392–5398. [Google Scholar] [CrossRef] [PubMed]
  12. Fest, E.C. Stray Light Analysis and Control; SPIE: Washington, DC, USA, 2013. [Google Scholar]
  13. Wang, H.; Chen, Q.; Ma, Z.; Yan, H.; Lin, S.; Xue, Y. Development and prospect of stray light suppression and evaluation technology. Acta Photonica Sin. 2022, 51, 0751406. [Google Scholar]
  14. Ge, Z.; Huang, Y.; Liu, Z. Analysis and calculation of the fill factor for microlens array scanning systems. Appl. Opt. 2021, 60, 11235–11240. [Google Scholar] [CrossRef] [PubMed]
  15. Ge, Z.; Huang, Y.; Liu, Z. Analysis and design of a microlens array scanning system based on spherical aberration. Appl. Opt. 2023, 62, 227–234. [Google Scholar] [CrossRef] [PubMed]
  16. Ge, Z.; Huang, Y.; Liu, Z. Effect of the fill factor on microlens array scanning system. SPIE 2023, 12507, 1250728. [Google Scholar] [CrossRef]
  17. Lv, Z.; Huang, Y.; Liu, Z. Analysis of fill factor and diffraction influence on micro-lens array imaging system. SPIE 2023, 12507, 1250726. [Google Scholar] [CrossRef]
  18. Liu, D. Micro Optics and Microlens Arrays; Chine Science Publishing & Media Ltd.: Beijing, China, 2013. [Google Scholar]
  19. Yu, D.; Tan, H. Engineering Optics, 3rd ed.; China Machine Press: Beijing, China, 2013. [Google Scholar]
Figure 1. Schematic diagram of the scanning principle of the microlens array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Figure 1. Schematic diagram of the scanning principle of the microlens array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Photonics 10 00104 g001
Figure 2. Schematic diagram of the crosstalk beam generated by the microlens array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Figure 2. Schematic diagram of the crosstalk beam generated by the microlens array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Photonics 10 00104 g002
Figure 3. Schematic diagram of crosstalk suppression based on the design of a multilayer array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Figure 3. Schematic diagram of crosstalk suppression based on the design of a multilayer array (green: SFOV, red: SFOV+IFOV, purple: SFOV-IFOV).
Photonics 10 00104 g003
Figure 4. Schematic diagram of the optical path to determine the aperture size using the edge light (purple: SFOV-IFOV).
Figure 4. Schematic diagram of the optical path to determine the aperture size using the edge light (purple: SFOV-IFOV).
Photonics 10 00104 g004
Figure 5. Schematic diagram of an example microlens array scanning imaging system (Y axis, δ = −2°, θ = −0.5°).
Figure 5. Schematic diagram of an example microlens array scanning imaging system (Y axis, δ = −2°, θ = −0.5°).
Photonics 10 00104 g005
Figure 6. Imaging diagrams under different IFOV situations. (a) Y axis, δ = −2°, θ = 0°, (b) Y axis, δ = −2°, θ = 0.5°, (c) Y axis, δ = −2°, θ = −0.5°.
Figure 6. Imaging diagrams under different IFOV situations. (a) Y axis, δ = −2°, θ = 0°, (b) Y axis, δ = −2°, θ = 0.5°, (c) Y axis, δ = −2°, θ = −0.5°.
Photonics 10 00104 g006
Figure 7. Imaging diagrams under four characteristic situations. (a) Y axis, δ = −2°, θ = −0.5°, (b) Y axis, δ = 2°, θ = 0.5°, (c) X axis, δ = −2°, θ = −0.5°, (d) X axis, δ = 2°, θ = 0.5°.
Figure 7. Imaging diagrams under four characteristic situations. (a) Y axis, δ = −2°, θ = −0.5°, (b) Y axis, δ = 2°, θ = 0.5°, (c) X axis, δ = −2°, θ = −0.5°, (d) X axis, δ = 2°, θ = 0.5°.
Photonics 10 00104 g007
Figure 8. Schematic diagram of an example microlens array scanning imaging system (Y axis, δ = −2°, θ = −2°).
Figure 8. Schematic diagram of an example microlens array scanning imaging system (Y axis, δ = −2°, θ = −2°).
Photonics 10 00104 g008
Figure 9. Imaging diagram with crosstalk suppression stop arrays (Y axis, δ = −2°, θ = −0.5°). (a) Schematic of non-crosstalk beams in the system, (b) Partial enlargement of system, (c) Structure diagram of crosstalk suppression stop arrays (left): stop array 1, (right): stop array 2), (d) Image power distribution on the plane.
Figure 9. Imaging diagram with crosstalk suppression stop arrays (Y axis, δ = −2°, θ = −0.5°). (a) Schematic of non-crosstalk beams in the system, (b) Partial enlargement of system, (c) Structure diagram of crosstalk suppression stop arrays (left): stop array 1, (right): stop array 2), (d) Image power distribution on the plane.
Photonics 10 00104 g009aPhotonics 10 00104 g009b
Figure 10. Diagram with crosstalk power values of the two rows. (Y axis, δ = −2°, θ = −0.5°).
Figure 10. Diagram with crosstalk power values of the two rows. (Y axis, δ = −2°, θ = −0.5°).
Photonics 10 00104 g010
Figure 11. Diagram with crosstalk power values of the two rows. (a) Y axis, δ = −2°, θ = 0°, (b) Y axis, δ = −2°, θ = 0.5°.
Figure 11. Diagram with crosstalk power values of the two rows. (a) Y axis, δ = −2°, θ = 0°, (b) Y axis, δ = −2°, θ = 0.5°.
Photonics 10 00104 g011
Figure 12. Schematic diagram of optical system with actual imaging system (Y axis, δ = −2°, θ = −0.5°).
Figure 12. Schematic diagram of optical system with actual imaging system (Y axis, δ = −2°, θ = −0.5°).
Photonics 10 00104 g012
Table 1. Parameters of the array system.
Table 1. Parameters of the array system.
ParameterValue
Array size13.5 mm × 13.5 mm
Number9 × 9
Single lens size1.5 mm × 1.5 mm
Layer2
Wavelength4 μm
Lens shaperectangle
Refractive indexn1 = n2 = 4.025058
SFOV δ 4° × 4°
IFOV θ 1° × 1°
Table 2. Power value (Watts) of each aperture (Y axis, δ = −2°, θ = −0.5°).
Table 2. Power value (Watts) of each aperture (Y axis, δ = −2°, θ = −0.5°).
123456789
10.0056390.0055030.0055350.0055030.0056390.0055030.0055350.0055030.005639
20.0048940.0047620.0047710.0047620.0048940.0047620.0047620.0047620.004894
30.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
40.0044870.0043550.0043550.0043550.0044860.0043550.0043550.0043550.004487
50.0044870.0043550.0043550.0043550.0044860.0043550.0043550.0043550.004487
60.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
70.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
80.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
90.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
Table 3. Power value (Watts) of each aperture (Y axis, δ = −2°, θ = −0.5°).
Table 3. Power value (Watts) of each aperture (Y axis, δ = −2°, θ = −0.5°).
123456789
10.0045510.0044150.0044150.0044150.0045510.0044150.0044150.0044150.004551
20.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
30.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
40.0044870.0043550.0043550.0043550.0044860.0043550.0043550.0043550.004487
50.0044870.0043550.0043550.0043550.0044860.0043550.0043550.0043550.004487
60.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
70.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
80.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
90.0044870.0043550.0043550.0043550.0044870.0043550.0043550.0043550.004487
Table 4. The positioning tolerance of 2 crosstalk suppression stop arrays.
Table 4. The positioning tolerance of 2 crosstalk suppression stop arrays.
Decenter X/YTilt About X/YDecenter ZTilt about Z
Crosstalk suppression stop array 1±0.05 mm30″±0.05 mm30″
Crosstalk suppression stop array 2±0.003 mm30″±0.05 mm30″
Table 5. Imaging for different SFOV and IFOV values when the wavelength is 4.0 μm.
Table 5. Imaging for different SFOV and IFOV values when the wavelength is 4.0 μm.
IFOV θ = 0°IFOV θ = 0.5°IFOV θ = −0.5°
SFOV δ = 0° Photonics 10 00104 i001 Photonics 10 00104 i002 Photonics 10 00104 i003
SFOV δ = −2° Photonics 10 00104 i004 Photonics 10 00104 i005 Photonics 10 00104 i006
Table 6. Imaging for different SFOV and IFOV values in different bands.
Table 6. Imaging for different SFOV and IFOV values in different bands.
IFOV θ = 0°IFOV θ = 0.5°IFOV θ = −0.5°
SFOV δ = 0° Photonics 10 00104 i007 Photonics 10 00104 i008 Photonics 10 00104 i009
SFOV δ = −2° Photonics 10 00104 i010 Photonics 10 00104 i011 Photonics 10 00104 i012
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Lv, Z.; Huang, Y.; Liu, Z. Analysis and Suppression of Crosstalk Beams in Microlens Array Scanning Imaging Optical System Based on the Combination of Multilayer Stop Arrays. Photonics 2023, 10, 104. https://doi.org/10.3390/photonics10020104

AMA Style

Lv Z, Huang Y, Liu Z. Analysis and Suppression of Crosstalk Beams in Microlens Array Scanning Imaging Optical System Based on the Combination of Multilayer Stop Arrays. Photonics. 2023; 10(2):104. https://doi.org/10.3390/photonics10020104

Chicago/Turabian Style

Lv, Zhiyang, Yunhan Huang, and Zhiying Liu. 2023. "Analysis and Suppression of Crosstalk Beams in Microlens Array Scanning Imaging Optical System Based on the Combination of Multilayer Stop Arrays" Photonics 10, no. 2: 104. https://doi.org/10.3390/photonics10020104

APA Style

Lv, Z., Huang, Y., & Liu, Z. (2023). Analysis and Suppression of Crosstalk Beams in Microlens Array Scanning Imaging Optical System Based on the Combination of Multilayer Stop Arrays. Photonics, 10(2), 104. https://doi.org/10.3390/photonics10020104

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop