1. Introduction
A cell containing one or more alkali metals, inert and buffer vapors, is commonly used as a core device in atomic clocks [
1], laser stabilizers [
2], and optical magnetometers [
3,
4,
5,
6,
7]. In magnetic field detection, spin-exchange-free spin (SERF) atomic magnetometers are highly valued for their ultra-high sensitivity. SERF atomic magnetometers are now widely used in biomedical [
8,
9] and geomagnetic exploration [
10] fields. The density of alkali metal vapor in the cell is closely related to its temperature. Alcock’s [
11] formula for the saturation vapor pressure of alkali metals can be used to calculate the temperature. The density of alkali metal vapor significantly affects the optical depth of the cell medium, atomic polarization, atomic relaxation rate, and other factors. Therefore, exploring the internal dynamic temperature of the alkali metal cell is important.
Traditional temperature measurement of the cell involves installing a resistance temperature detector (RTD) on the outer wall of the cell, which is non-destructive [
12]. However, this method has limitations. This is because the saturated vapor pressure of the cell is determined by the lowest temperature point of the entire cell, but the external temperature of the cell is not consistent, making it difficult to find the lowest temperature point of the alkali metal cell.
To address this problem many scholars have studied methods for cell temperature measurement. Shang et al. [
13] used atomic absorption spectrometry (AAS) to obtain the internal temperature of the cell, which is more accurate than using RTD. Meanwhile, many scholars have found that the atomic vapor density obtained by RTD temperature using Killian’s formula is much higher than the true atomic vapor density. Shao et al. [
14] measured the density of alkali metal vapor, which is about half of the result calculated by the Killian formula; Shang et al. [
15] come to the same conclusion based on the measurement of alkali metal vapor density using the Faraday modulator. The reason for this phenomenon is currently unknown, but obtaining the true temperature inside the cell is an area worth exploring.
The methods for measuring the temperature of the cell are divided into two types: contact and non-contact. The non-contact measurement method is based on AAS. It offers high sensitivity, calibration-free operation, fast detection, and the ability to remotely measure the internal dynamic temperature inside the cell without entering the cell [
15]. Therefore, the AAS temperature measurement method is beneficial for measuring the temperature inside the cell. RTDs have high measurement accuracy and stable performance, which is suitable for measuring temperature signals. Therefore, RTD-based temperature measurement is also suitable for measuring the temperature of cells. However, both temperature measurement methods have technical drawbacks that are hard to avoid. Measurements using RTDs require additional calculations to obtain the temperature at the center of the cell. Hence, temperature measurements using this method are inaccurate. AAS temperature measurement utilizes fitting absorption spectra, but measurement becomes challenging when the vapor density is high. This is because directly measuring the extremely weak transmitted light near resonance is difficult. Moreover, severe attenuation of light within the resonance linewidth makes it hard to determine the absorption line shape, which makes it impossible to measure through far detuned measurement [
16]. Additionally, AAS measurement is affected by factors such as power fluctuations and changes in external magnetic fields. As a result, AAS may not be an accurate method for temperature measurement [
17]. In this study, the results of indirect temperature measurement by RTD, temperature measurement by AAS, and direct temperature measurement of the external wall by RTD are compared. This study has found that measured temperatures vary greatly, especially during periods of increased internal dynamic temperature. The dynamic internal temperature of the cell requires a high precision measurement, but the results obtained from different temperature measurement methods may vary. Measuring the internal dynamic temperature of a cell requires high accuracy. For this purpose, a method of fusing data from two temperature measurement devices is used to measure the internal dynamic temperature of the cell. This multimodal sensor-data fusion method allows more accurate measurements [
18]. Multi-sensor data fusion is useful when the measured temperature by a single sensor does not have the desired precision. So, the data from multiple sensors is processed to compensate for the individual sensor’s deficiencies [
19]. The data fusion methods are mainly divided into two types: modern and classical fusion methods. The modern fusion methods are based on neural networks [
20], cluster analysis [
21], and intelligent algorithms [
22]. The classical fusion methods revolve around the Kalman filter (KF) [
23] and Bayesian estimation [
24].
Many research studies have been done on the KF data fusion method. Sun et al. [
25] proposed an optimal information fusion dispersion KF for multiple sensors and verified the effectiveness of the method with a three-sensor radar tracking system. Wang et al. [
26] fused the signals from lead-zirconium-titanium oxide (PZT) sensors and optical fiber sensors for monitoring bore edge cracks through a weighted adaptive KF. They found that the method could significantly improve the accuracy compared to single-sensor monitoring. Xu et al. [
27] used KF to fuse resolution-enhanced surface temperature data with coarse-resolution surface temperature data to obtain a more accurate set of surface temperatures with a root mean square error in the range from 0.79–1.47 K. Chen et al. [
28] proposed a KF-based algorithm to fuse temperature and humidity data. The experimental results showed that the algorithm filtered the data noise, reduced the data measurement error, and obtained highly accurate values.
The KF is used to fuse the measurement data from multimodal sensors. The KF acquires accurate data by combining the model state estimation with the observed data [
29]. It can obtain a better set of measurements for the same object. In this study, the KF is used to measure the more accurate internal dynamic temperature of the cell. It is done by fusing correlated time series data of AAS and RTD.
The structure of this article is as follows. Firstly, the acquisition of the external wall temperature data of the vapor cell and the AAS measurement data related to the internal dynamic temperature of the cell is presented. Afterward, the data processing of the internal dynamic temperature of the cell is discussed. Next, the calculation of the internal dynamic temperature of the cell through KF data fusion for a more accurate internal dynamic temperature of the cell is done. Finally, the fusion results are compared with the external wall measurements of RTD to verify the KF fusion results. In the end, it is shown, based on the experimental results, that it is feasible to measure the internal dynamic temperature of the cell with multiple sensor data after processing with KF.
2. Measurement Procedures
2.1. AAS Temperature Measurement
Due to the lack of hyperfine pumping, hyperfine absorption is completely overlapped. Hence, the optical depth of the target can be measured according to the change in light intensity. The schematic diagram of the AAS setup is shown in
Figure 1. Based on Lambert’s law, the relationship between the corresponding quantities is presented in Equation (1) [
30]:
where
I(
I) is the light intensity of the laser incident on the cell,
I(
O) is the light intensity of the laser exiting the cell,
OD is the optical depth,
is the atomic density of the alkali metal vapor,
s is the photon absorption cross-section, and
l is the optical length of the laser beam in the cell.
The buffer gas atom causes a linear Lorentz broadening between atoms. To avoid collision relaxation, the cell used in the experiment injects three atmospheres of
4He. Under these conditions, an approximate broadening of 50 GHz is observed, and saturated absorption peaks were not visible. Consequently, based on a known set of measurement data, the single peak Lorentz function in Equation (2) is capable of fitting the data [
31]. The fitting results are then used to calculate the full width at half maximum (FWHM)
, the center frequency
v0.
Substituting
of the curve into Equation (3) representing the absorption area at the resonant frequency point, the photon absorption cross-sectional area
can be calculated as follows [
32].
In Equation (3),
re is the electron radius,
c is the speed of light in vacuum, and
f is the intensity of the oscillator. The atomic density
n of alkali metal vapor is obtained through Equation (4), where
ODmax is the maximum optical depth,
is the maximum photon absorption cross-sectional area at resonance [
33]:
The empirical formula given in Equation (5) presents the relationship between cell temperature and the atomic density of alkali metal vapor [
11,
13]:
Equation (5) provides the cell temperature TG if all the other quantities are known. A and B are the density parameters of liquid rubidium (Rb) vapor with the following values A = 31.178 and B = 4040.
2.2. RTD Indirect Temperature Measurement
The RTD temperature measurement method is invasive, which means that it needs to be in direct contact with the object being measured. However, because the cell is non-destructive and the RTD is pre-installed during cell manufacturing, the RTD may be corroded by alkali metal vapor. As a result, RTD can only measure the temperature of the outer wall of the cell.
According to Fourier’s law of heat conduction, heat will move from a high temperature region to a low temperature region when there is non-uniform temperature distribution. Equation (5) indicates that the temperature of the cell is directly proportional to the atomic density of alkali metal vapor. The electric heating plate is in close contact with the cell while it is being charged and heated. The lack of internal heating in the cell results in a slight gradient of temperature along its radius. Thus, the external wall of the cell with a radius of 10 mm can be simulated as being in a state of thermal equilibrium. In the transient case of 428 K, the cell is simulated in two dimensions. In the two-dimensional case, the temperature distribution in the cell is approximated by the two-dimensional Gaussian distribution model shown in
Figure 2. Therefore, in this work, a simplified temperature distribution model is proposed, in which the temperature distribution of the cell is considered to have an inverse Gaussian function.
This article describes a simple simulation of the constant temperature situation in the 428 K cell, as shown in
Figure 2a. In this case, the temperature of the cell has reached a steady state. We treat the cell wall as a constant temperature heat source, regardless of the temperature exchange between the cell and the environment.
Thus, the isotherms of the cell can be simplified into regular circles. When measured outside the cell, the extended isotherms of the heat source at any point are perpendicular to the heat transfer and, as a result, must pass through the center of the spherical cell. Additionally, assuming that heat transfer comes from an infinite number of equivalent heat sources, a way to estimate cell temperature from the temperature of the outer wall is provided.
The concentration of alkali metal vapor in the cell is determined by the point where the alkali condenses at low temperatures. However, Guo et al. [
34] found that the distribution of alkali metal vapor within the cell is not uniform, and the reason for this is not fully understood. Therefore, let’s consider Equation (1) and assume that the object has the same atomic density at the same temperature. In the full optical range, there are
i optical lengths of varying density, and each optical length with the same density is considered a unit length. By substituting these variables in Equation (1), we can express the attenuation coefficient of laser light passing through the cell as
, and the corresponding optical length as
. The following expression is obtained:
The internal distribution of alkali metal vapor in the heating cell is not uneven. From Equations (4) and (5) it is clear that temperature, optical depth, and alkali metal vapor density are positively correlated. Therefore, the variation of the attenuation coefficient is also distributed in the inverted Gaussian function. Hence, Equation (7) can be used to represent the optical depth of the medium within a certain range.
la and
lb are the lower and upper limits within the cell.
Substituting this value in Equations (4) and (5) gives the temperature TD at a point in the interval.
2.3. KF Fusion Algorithm
The KF is a recursive optimization algorithm whose main application is in time-varying dynamic systems with uncertainty [
25]. It is difficult to establish an accurate mathematical model of the internal dynamic temperature of a cell. Whether the internal dynamic temperature of the cell is extrapolated from RTD measurements or measured by AAS, there will always be unmeasurable errors. Therefore, the use of a KF for data fusion is very appropriate.
The spatial state system model of the object under test can be expressed as:
where
x(
k) is the state matrix of the object under observation at the moment
k.
y(
k) is the state observation signal of the object under test at the moment
k.
w(
k) is the process noise at the moment
k.
v(
k) is the observation noise at the moment
k.
A and
H are the state transfer matrix and the observation matrix, respectively. Both
w(
k) and
v(
k) are Gaussian white noises, and their corresponding covariance matrices are
Q and
R. The core formula for the KF is as follows [
28].
Updated state space:
where
x(
k|
k − 1) is the estimate obtained from the optimal estimate at
k − 1.
K(
k) is the Kalman gain at
k.
x(
k) is the optimal estimate at
k.
P(
k) is the covariance matrix at
k, and
I is the unit matrix.
Data fusion with KF is the analysis of the sensor data followed by the execution of the KF algorithm to obtain an optimum estimate of the measured values. The best estimate from Equation (13) can be considered the optimal fusion of the observations and estimates consisting of time series signals collected by multiple sensors. The KF-based equation of state for the internal dynamic temperature of the cell can be expressed as Equations (15) and (16):
where
TG(
k) is the temperature measured using AAS.
TD(
k) is the temperature measured using RTD indirect temperature measurement method.
BG is the observation matrix for temperature measurement using AAS.
BD is the observation matrix for temperature measurement using RTD.
vG(
k) and
vD(
k) are the measurement noises for both methods. According to the core formula of the KF, a relationship given in Equation (17) exists between the two unrelated measurements.
where
TF is the temperature obtained after KF fusion,
DG and
DD are the variance of the two measurements, which can be obtained from multiple measurements at a fixed temperature.
To test the effectiveness of the data fusion algorithm that relied on KF, we conducted a simple simulation. During the simulation, the standard deviations of inputs A and B are 0.5 and 0.4, respectively.
Figure 3 shows the KF fusion result, demonstrating the potential temperature signals using KF fusing. The simulate output’s standard deviation was reduced to 0.31, indicating the efficacy of the signal fusion algorithm using KF in temperature measurement experiments on cells.
3. Experimental Setups
The experimental setup consists of a Rb atomic cell, heating oven, electric heating plate, a computer, UniQuanta laser (DFB801-795), two photodetectors (S142C), optical power meter (PM100USB), RTD data acquisition card (M2111) and four RTDs. The schematic diagram of the experimental setup is shown in
Figure 4. A 20 mm diameter spherical borosilicate glass cell containing Rb atoms, quenching gas N
2, and buffer gas
4He is placed in an oven made of boron nitride. The heating capacity of the oven is provided by two non-magnetic, temperature-controlled electric heating plates with a maximum heating capacity of 473 K. N
2, and
4He gases do not produce absorption peaks in the visible light band. In the visible light band, the wavelength of Rb atomic line is at about 794.98 nm. Therefore, the N
2 and
4He gases do not affect the experiment. Four RTDs are attached to the outer wall of the cell on both sides of the two ventilation holes. The RTDs are small enough (2 × 5 mm) not to obstruct the transmission of light. This ensures that the RTDs can obtain the most direct temperature of the outer wall of the cell. This also prevents experimental failure due to the malfunction of the small RTDs during experiments. The temperature value measured by the RTD is the average of four individual temperature measurements.
The heated oven is packed in a non-magnetic tank with two ventilation holes. The detection light enters through a vent on one side of the tank, passes through the cell, and exits through a vent on the other side. A distributed feedback laser supplies the detection light with a central wavelength of 795 nm. After passing through two plano-convex lenses, the beam is transformed into a linearly polarized beam by using a Glan-Taylor prism as a polarizer. The linearly polarized beam is split in two with a 1:1 ratio using a non-polarization beam splitter (NPBS). One of the beams is directly captured by the photodetector PD1 to detect the intensity of the light. The other beam is captured by the photodetector PD2 after passing through the oven and being absorbed by the Rb atoms to detect the intensity of the light.
Since the cell needs to reach a specific temperature before it can start working, the data for this experiment is recorded from when the temperature of the cell reached 373 K and ended when the external temperature control section of the cell showed a stable temperature of 428 K. A total of 10,800 sampling points were recorded.
Finally, two sets of dynamic internal cell temperatures were obtained for data fusion. Another data set, the external wall’s internal dynamic temperature, measured directly, was used for subsequent comparison.
4. Results and Discussion
To measure temperature using AAS, it is necessary to scan DFB lasers near the Rb atomic D1 line to obtain optical depths at different laser frequencies. This is required due to the optical thickness that occurs at higher temperatures and drifts in the DFB laser during usage, which makes it difficult to measure temperature at a fixed frequency. To conduct the experiment, the oven must first be set to a certain temperature. After the oven has reached the desired temperature and has stabilized within a fluctuation range of ±0.1 K, adjust the wavelength of the DFB laser to scan near the Rb atom’s D1 line. It is important to note that the wavelength adjustment step size of the DFB laser varies. Near the D1 line, the step size is 0.08 nm, while it is 0.16 nm, 0.24 nm, and 0.4 nm away from the D1 line. This process was repeated at each working temperature of the cell to calibrate the temperature measurement by AAS.
The OD obtained by AAS varies at different temperatures. This is because, as the cell temperature increases,
I(
O) gradually decreases while
I(
I) remains constant. To ensure consistent evaluation of the residual sum of squares (RSS) evaluation indicators for different sets of data after fitting, OD was normalized. RSS is a metric that measures the sum of squares between the actual value
and the fitted value
. Usually lower values indicates a better fit. The expression for RSS can be found in Equation (18).
Normalization does not affect the data wavelength and therefore does not affect the FWHM obtained after fitting. In this experiment, extreme difference normalization was selected, as shown in Equation (19):
Temperature measurements by AAS were carried out in 5 K intervals in the operating temperature range of 333–428 K inside the Rb cell. The optical depth as a function of wavelength is obtained over the wavelength range of 794–796 nm in various intervals, as shown in
Figure 5, which illustrates the absorption peaks at each sampling temperature.
The results in
Figure 5a indicate that the absorption peak exhibits significant fluctuations on both sides below 333 K, which could be attributed to the incomplete work of the cell. Moreover,
Figure 5b–e demonstrates that the absorption peaks become more optically thick as the temperature increases. The waveforms of the absorption peaks also gradually become irregular from the Lorentzian type, resulting in incomplete fitting. An optically thick phenomenon is evident after 398 K.
Table 1 shows that after 11 iterations of fitting with the Lorentz function, the raw data obtained with AAS provides a better fit at low temperatures, but a poorer fit at high temperatures. Inaccuracies in the FWHM obtained by the Lorentz fit can occur due to lower fits, resulting in deviations in calculated temperatures. The high atomic density of the alkali metal vapor at higher temperatures results in complete absorption of the incident beam, ultimately leading to an optically thick absorption peak. In addition, when the laser emitted from the cell is very small, the limited sensitivity of the photodetector resulting in intensity values is unmeasurable, leading to flat peaks. This variance is significant because the indirect RTD measurement method calculates the internal dynamic temperature of the cell using the external temperature of the cell measured by the RTD, and Equation (7) is used in this process. It can seriously affect the accurate measurement of the internal dynamic temperature of the cell.
To ensure the accuracy of the data fusion via KF, the oven was cooled to room temperature and reheated to 373 K. Afterwards, both temperature measurement methods were repeated once the temperature stabilized, with fluctuations around ±0.1 K. The purpose of these measurements was to calculate the variance of the respective methods. The final variance values are D
G = 0.0517 and D
D = 0.1059. Subsequently, the data from two temperature measurement methods were fused by KF. The results are displayed in
Figure 6.
Figure 6 indicates that the KF fused data is not as high or low as the input data. This is because the output data combines the characteristics of the two input data sets using KF. In this study, the non-magnetic electric heating plates method was used to increase the temperature. However, this method resulted in a sudden temperature rise, most likely due to frequency variation of the plates. This sudden increase in temperature after KF data fusion cannot be eliminated. The consistency of the three curves is high because the measurement data of AAS used RTD measurement data as a reference, resulting in the same trend of the two sets of data. The KF fusion results calculated by Equation (17) also obtained this trend information, thereby ensuring higher consistency.
As shown in
Figure 7, the atomic vapor density calculated from the temperature values obtained by fusing the KF data is approximately 37% lower on average than the corresponding values from conventional external wall temperature measurements. This finding is consistent with the results of other studies on calculating atomic vapor density [
14,
15,
35,
36]. Furthermore, the density of atomic vapor within the cell becomes progressively more homogeneous as the temperature increases. This is due to the gradual increase of the ratio between the two results. However, after 10,000 s, the temperature increase reaches a state of stagnation. Even when the temperature is stabilized, there is still a 20% difference between the measurement results of the two methods, which may be attributed to the inhomogeneous temperature of the cell.