Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane
Abstract
:1. Introduction
1.1. Separation Methods
1.2. Review of the Carbon Dioxide Removal by Applying Ionic Liquids
1.2.1. Numerical Simulations of Carbon Separations by Applying Ionic Liquids
1.2.2. Review of CO2 Removal Membranes
1.2.3. HITRAN Spectral Database
1.2.4. Scope and Novelty of This Paper
2. Materials and Methods
2.1. Diffusion Coefficients of Ionic Liquid
2.2. Multiphysics Analyses of the Carbon Removal Device
2.2.1. Fluid Flow and Continuity Equations
2.2.2. Diffusion Equations inside the CO2 Removal System
2.2.3. Boundary Conditions
2.3. IR Radiative Properties of CO2—LBL Model
- (a).
- Spectral Line Data: The method relies on a comprehensive spectroscopic database, such as HITRAN (high-resolution transmission molecular absorption) or other similar databases. These databases provide information about molecular absorption lines, including their positions, intensities, broadening parameters, and other relevant parameters.
- (b).
- Line Shape Function: To account for the Doppler, pressure, and temperature broadening effects (In this case the HITEMP is applied—see Figure 1), the spectral lines’ shapes are usually convoluted with appropriate line shape functions, such as the Voigt profile, which combines both Gaussian and Lorentzian line shapes.
3. Results
3.1. Calculation Results of the Infrared (IR) Radiation Absorption of CO and CO2
3.2. Numerical Model Convergence
4. Conclusions and Future Work
- (1)
- High selectivity: Ionic liquids can exhibit high selectivity for CO2 capture, allowing for efficient separation from gas mixtures. Their unique chemical structures and tunable properties can be designed to enhance CO2 absorption while minimizing the absorption of other gases.
- (2)
- Low volatility: Ionic liquids are non-volatile, meaning they have negligible vapor pressure at ambient conditions. This characteristic eliminates the risk of emissions from solvent evaporation, making them safer and more environmentally friendly.
- (3)
- Wide temperature range: Ionic liquids can be tailored to remain in a liquid state over a broad temperature range, including near-ambient conditions. This flexibility enables their use in various carbon capture applications, including flue gas from power plants or industrial processes.
- (4)
- Chemical stability: Ionic liquids are typically chemically stable and can withstand harsh conditions, such as high temperatures and corrosive environments. This stability allows for long-term use without significant degradation or the need for frequent replacement.
- (5)
- Lower energy requirements: Ionic liquids can have low energy requirements for CO2 desorption, enabling more energy-efficient carbon capture processes. The energy demand for regeneration can be reduced compared to traditional solvents, resulting in lower operational costs.
- (6)
- Potential for reuse: Ionic liquids can be regenerated and reused multiple times without significant loss of performance or capacity. This feature contributes to the economic viability of carbon capture technologies by reducing the overall cost of the solvent.
- (7)
- Reduced environmental impact: Ionic liquids can offer a greener alternative for carbon capture due to their low volatility, reduced energy requirements, and potential for recycling. They can help mitigate greenhouse gas emissions while minimizing the environmental impact associated with traditional solvent-based processes.
- (8)
- Versatility: Ionic liquids can be synthesized with a wide range of chemical functionalities, allowing for customization to specific carbon capture applications. Their properties can be fine-tuned to optimize performance, making them adaptable to different operating conditions and gas compositions.
- (a).
- Spectral line data: The method relies on a comprehensive spectroscopic database, such as HITRAN (high-resolution transmission molecular absorption) or other similar databases. These databases provide information about molecular absorption lines, including their positions, intensities, broadening parameters, and other relevant parameters.
- (b).
- Line shape function: To account for the Doppler, pressure, and temperature broadening effects (in this case, the HITEMP is applied), the spectral lines’ shapes are usually convoluted with appropriate line shape functions, such as the Voigt profile, which combines both Gaussian and Lorentzian line shapes.
Funding
Conflicts of Interest
Nomenclature
c | Concentration in [mole/m3] |
D | Diffusion coefficient in [m2/s] |
p | Pressure in [Pa] |
Atmospheric pressure in [Pa] | |
Gas constant (8.3143 J/(mole·K)) | |
Inner radius of the tube [m] | |
Outer radius of the tube [m] | |
Velocity vector in [m/s] | |
Subscripts | |
In | Inlet, inner radius |
Out | Outlet, outer |
Greek letters | |
η | Viscosity of the gaseous mixture in [Pa·s] |
ν | Velocity of the gaseous mixture in [m/s] |
ρ | Density of the gaseous mixture in [kg/m3] |
Abbreviations
IL | Ionic liquid |
IR | Infrared |
References
- McCabe, W.L.; Smith, J.C. Unit Operations of Chemical Engineering, 2nd ed.; MacGraw-Hill, Inc.: New York, NY, USA, 1967. [Google Scholar]
- Omecinski, K.S.; Federspiel, W.J. Improvement of a Mathematical Model to Predict CO2 Removal in Hollow Fiber Membrane Oxygenators. Bioengineering 2022, 9, 568. [Google Scholar] [CrossRef] [PubMed]
- Alabdullh, H.A.; Pflaum, M.; Mälzer, M.; Kipp, M.; Naghilouy-Hidaji, H.; Adam, D.; Kühn, C.; Natanov, R.; Niehaus, A.; Haverich, A.; et al. Biohybrid lung Development: Towards Complete Endothelialization of an Assembled Extracorporeal Membrane Oxygenator. Bioengineering 2023, 10, 72. [Google Scholar] [CrossRef] [PubMed]
- Gu, K.; Gao, S.; Zhang, Z.; Ji, B.; Chang, Y. Hemodynamic Effect of Pulsatile on Blood Flow Distribution with VA ECMO: A Numerical Study. Bioengineering 2022, 9, 487. [Google Scholar] [CrossRef] [PubMed]
- Fang, Z.; Smith, R.L., Jr.; Qi, X. Productions of Biofuels and Chemicals with Ionic Liquid; Springer: Dordrecht, The Netherlands, 2014. [Google Scholar]
- Tran, A.T.; Tomlin, J.; Lam, P.H.; Stinger, B.L.; Miller, A.D.; Walczyk, D.J.; Cruz, O.; Vaden, T.D.; Yu, L. Conductivity, Viscosity, Spectroscopic Properties of Organic Sulfonic Acid solutions in Ionic Liquids. ChemEngineering 2019, 3, 81. [Google Scholar] [CrossRef] [Green Version]
- Wu, B.; Reddy, R.G.; Rogers, R.D. Novel Ionic Liquid Thermal Storage for Solar Thermal Electric Power Systems. In Proceedings of the ASME 2001 Solar Engineering: International Solar Energy Conference (FORUM 2001: Solar Energy—The Power to Choose), Washington, DC, USA, 21–25 April 2001. [Google Scholar]
- Roman, F.F. Biodiesel Production through Esterification Applying Ionic Liquid as Catalyst. Master’s Thesis, Escola Superior de Tecnologia e Gestão do Instituto Politécnico de Bragança, Bragança, Portugal, 2018. [Google Scholar]
- Elsheikh, Y.A.; Man, Z.; Bustam, M.A.; Yusup, S.; Wilfred, C.D. Brønsted imidazolium ionic liquids: Synthesis and comparison of their catalytic activities as pre-catalyst for biodiesel production through two stage process. Energy Convers. Manag. 2011, 52, 804–809. [Google Scholar] [CrossRef]
- Kuzmina, O.; Hallet, J.P. Application Purification and Recovery of Ionic Liquid; Elsevier: Amsterdam, The Netherlands, 2016. [Google Scholar]
- Fleury, E.; Kittel, J.; Vuillemin, B.; Oltra, R.; Ropital, F. Corrosion in Amine Solvents Used for the Removal of Acid Gases; Eurocorr: Edinburgh, UK, 2008; Available online: https://hal-ifp.archives-ouvertes.fr/hal-02475507/document (accessed on 9 July 2023).
- Hatcher, N.A.; Jones, C.E.; Weiland, G.S.; Weiland, R.H. Predicting Corrosion Rates in Amine and Sour Water Systems. Digital Refining Processing, Operations & Maintenance Website. May 2014. Available online: https://www.digitalrefining.com/article/1000923/predicting-corrosion-rates-in-amine-and-sour-water-systems#.Yz7OEz1BzX4 (accessed on 6 October 2022).
- Sohaib, Q.; Manuel Vadillo, J.; Gómez-Coma, L.; Albo, J.; Druon-Bocquet, S.; Irabien, A.; Sanchez-Marcano, J. Post-combustion CO2 capture by coupling [emim] cation based ionic liquids with a membrane contactor; Pseudo-steady-state approach. Int. J. Greenh. Gas Control 2020, 99, 103076. [Google Scholar] [CrossRef]
- Qazi, S.; Gómez-Coma, L.; Albo, J.; Druon-Bocquet, S.; Irabien, A.; Younas, M.; Sanchez-Marcano, J. Mathematical modeling of CO2 absorption with ionic liquids in a membrane contactor, study of absorption kinetics and influence of temperature. J. Chem. Technol. Biotechnol. 2020, 95, 1844–1857. Available online: https://hal.science/hal-02930318 (accessed on 9 July 2023). [CrossRef]
- Xie, Y. CO2 Separation with Ionic Liquids—From Properties to Process Simulation. Ph.D. Thesis, Energy Engineering Division of Energy Science Department of Engineering Sciences & Mathematics, Luleå University of Technology, Luleå, Sweden, October 2016. [Google Scholar]
- Altintas, C.; Keskin, S. MOF adsorbents for flue gas separation: Comparison of material ranking approaches. Chem. Eng. Res. Des. 2022, 179, 308–318. [Google Scholar] [CrossRef]
- Mulder, M. Basic Principles of Membrane Technology; Kluwer Academic Publishers: Dordrecht, The Netherlands, 1996. [Google Scholar]
- Ghasem, N. Chemical Absorption of CO2 Enhanced by Nanoparticles Using a Membrane Contactor: Modeling and Simulation. Membranes 2019, 9, 150. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Al-Marzouqi, M.H.; Marzouk, S.A.; El-Naas, M.H.; Abdullatif, N. CO2 Removal from CO2−CH4 Gas Mixture Using Different Solvents and Hollow Fiber Membranes. Ind. Eng. Chem. Res. 2009, 48, 3600–3605. [Google Scholar] [CrossRef]
- Thakkar, H.; Eastman, S.; Hajari, A.; Rownaghi, A.A.; Knox, J.C.; Rezaei, F. 3D-Printed Zeolite Monoliths for CO2 Removal from Enclosed Environments. ACS Appl. Mater. Interfaces 2016, 8, 27753–27761. [Google Scholar] [CrossRef]
- Michenkova, M.; Taki, S.; Blosser, M.C.; Hwang Hyea, J.; Kowatz, T.; Moss Fraser, J.; Occhipinti, R.; Qin, X.; Sen, S.; Shinn, E.; et al. Carbon dioxide transport across membranes. Interface Focus 2021, 11, 20200090. [Google Scholar] [CrossRef] [PubMed]
- Chuah, C.Y.; Kim, K.; Lee, J.; Koh, D.Y.; Bae, T.H. CO2 Absorption Using Membrane Contactors: Recent Progress and Future Perspective. Ind. Eng. Chem. Res. 2020, 59, 6773–6794. [Google Scholar] [CrossRef]
- Martins, C.F. CO2 Removal from Anesthesia Circuits Using Gas-Ionic Liquid Membrane Contactors. Ph.D. Thesis, Chemical and Biochemical Engineering, NOVA University of Lisbon, Lisbon, Portugal, 2020. [Google Scholar]
- Martins, C.F.; Neves, L.A.; Chagas, R.; Ferreira, L.M.; Afonso, C.A.M.; Crespo, J.G.; Coelhoso, I.M. CO2 removal from anesthesia circuits using gas-ionic liquid membrane contactors. Sep. Purif. Technol. 2020, 250, 116983. [Google Scholar] [CrossRef]
- McClatchey, R.A.; Benedict, W.S.; Clough, S.A.; Burch, D.E.; Fox, K.; Rothman, L.S.; Garing, J.S. AFCRL Atmospheric Absorption Line Parameters Compilation; AFCRL (Air Force Cambridge Research Laboratory) Technical Report 0096; AFCRL: Cambridge, MA, USA, 1973. [Google Scholar]
- Rothman, L.S.; Schroeder, J.; Tang, K. Java HITRAN Atmospheric Workstation; Manual; Atomic and Molecular Physics Division Harvard-Smithsonian Center for Astrophysics: Cambridge, MA, USA, 2003. [Google Scholar]
- Gordon, I.E.; Rothman, L.S.; Hargreaves, R.J.; Hashemi, R.; Karlovets, E.V.; Skinner, F.M.; Conway, E.K.; Hill, C.; Kochanov, R.V.; Tan, Y.; et al. The HITRAN2020 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 2022, 277, 107949. [Google Scholar] [CrossRef]
- Pechar, T.W. Fabrication and Characterization of Polyimide-Based Mixed Matrix Membranes for Gas Separations. Ph.D. Thesis, Virginia Polytechnic and State University, Blacksburg, VA, USA, July 2004. [Google Scholar]
- Lin, H. Solubility Selective Membrane Materials for Carbon Dioxide Removal from Mixtures with Light Gases. Ph.D. Thesis, Faculty of the Graduate School of the University of Texas at Austin, Austin, TX, USA, 2005. [Google Scholar]
- Bahlake, A.; Farivar, F.; Dabir, B. New 3-dimensional CFD modeling of CO2 and H2S simultaneous stripping from water within PVDF hollow fiber membrane contactor. Heat Mass Transf. 2016, 52, 1295–1304. [Google Scholar] [CrossRef]
- COMSOL Multiphysics—Modeling Guide; Version 4.3b; COMSOL AB: Stockholm, Sweden, 2013.
- Rothman, L.S.; Rinsland, C.P.; Goldman, A.; Massie, S.T.; Edwards, D.P.; Flaud, J.M.; Perrin, A.; Camy-Peyret, C.; Dana, V.; Mandin, J.Y.; et al. The HITRAN Molecular Spectroscopic Database and HAWKS (HITRAN Atmospheric Workstation): 1996 Edition. J. Quant. Spectrosc. Radiat. Heat Transf. 1998, 60, 665–710. [Google Scholar] [CrossRef]
- Taine, J.; Soufiani, A.; Riviere, P.; Perrin, M.Y. Recent Developments in Modeling the Infrared Radiative Properties of Hot Gases. In Proceedings of the 11th International Heat Transfer Conference (IHTC), Kyongju, Republic of Korea, 23–28 August 1998; Volume 1, pp. 175–187. [Google Scholar]
- Davidy, A.; Zvirin, Y. Development of the inverse radiative method for measuring gaseous and particles concentrations in the exhaust plume by using remote sensing method. In Proceedings of the AIAA-2005-3577, 41st AIAA/ASME/SAE/ASEE Joint Propulsion Conference and Exhibit, Tucson, AZ, USA, 10–13 July 2005. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Davidy, A. Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane. ChemEngineering 2023, 7, 60. https://doi.org/10.3390/chemengineering7040060
Davidy A. Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane. ChemEngineering. 2023; 7(4):60. https://doi.org/10.3390/chemengineering7040060
Chicago/Turabian StyleDavidy, Alon. 2023. "Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane" ChemEngineering 7, no. 4: 60. https://doi.org/10.3390/chemengineering7040060
APA StyleDavidy, A. (2023). Numerical Study of CO2 Removal from Inhalational Anesthesia System by Using Gas-Ionic Liquid Membrane. ChemEngineering, 7(4), 60. https://doi.org/10.3390/chemengineering7040060