Next Article in Journal
Multimodality Imaging of the Anatomy of Tricuspid Valve
Previous Article in Journal
Efficacy of Lipid-Lowering Therapy during Cardiac Rehabilitation in Patients with Diabetes Mellitus and Coronary Heart Disease
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Brief Report

Can the Addition of NT-proBNP and Glucose Measurements Improve the Prognostication of High-Sensitivity Cardiac Troponin Measurements for Patients with Suspected Acute Coronary Syndrome?

1
Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON L8S 4L8, Canada
2
Department of Medicine, Division of Emergency Medicine, McMaster University, Hamilton, ON L8S 4L8, Canada
3
Department of Medicine, Division of Cardiology, McMaster University, Hamilton, ON L8S 4L8, Canada
*
Author to whom correspondence should be addressed.
J. Cardiovasc. Dev. Dis. 2021, 8(9), 106; https://doi.org/10.3390/jcdd8090106
Submission received: 27 July 2021 / Revised: 19 August 2021 / Accepted: 30 August 2021 / Published: 1 September 2021

Abstract

:
Guidelines published in 2021 have supported natriuretic peptide (NP) testing for the prognostication in patients with acute coronary syndrome (ACS) and for the diagnosis of chronic and acute heart failure (HF). Our objective was to determine if the addition of N-terminal pro B-type NP (NT-proBNP) and glucose to high-sensitivity cardiac troponin (hs-cTn) could better identify emergency department (ED) patients with potential ACS at low- and high-risk for a serious cardiovascular outcome over the next 72 h. The presentation sample in two different ED cohorts which enrolled patients with symptoms suggestive of ACS within six hours of pain onset (Cohort-1, n = 126 and Cohort-2, n = 143) that had Abbott hs-cTnI, Roche hs-cTnT, NT-proBNP and glucose were evaluated for NT-proBNP alone and combined with hs-cTn and glucose for the primary outcome (composite which included death, myocardial infarction, HF, serious arrhythmia and refractory angina) via receiver-operating characteristic (ROC) curve analyses with area under the curve (AUC) and diagnostic estimates derived. The AUC for NT-proBNP for the primary outcome was 0.68 (95% confidence interval (CI): 0.59–0.76) and 0.75 (95%CI: 0.67–0.82) in Cohort-1 and 2, respectively, with the 125 ng/L cutoff yielding a higher sensitivity (≥75%) as compared to the 300 ng/L cutoff (≥58%). Using the 125 ng/L cutoff for NT-proBNP with the published glucose and hs-cTn cutoffs for risk-stratification produced a new score (GuIDER score for Glucose, Injury and Dysfunction in the Emergency-setting for cardiovascular-Risk) and yielded higher AUCs as compared to NT-proBNP (p < 0.05). GuIDER scores of 0 and 5 using either hs-cTnI/T yielded sensitivity estimates of 100% and specificity estimates > 92% for the primary outcome. A secondary analysis assessing MI alone in the overall population (combined Cohorts 1 and 2) also achieved 100% sensitivity for MI with a GuIDER cutoff ≥ 2, ruling-out 48% (Roche) and 38% (Abbott) of the population at presentation for MI. Additional studies are needed for the GuIDER score in both the acute and ambulatory setting to further refine the utility, however, the preliminary findings reported here may present a pathway forward for inclusion of NP testing for ruling-out serious cardiac events and MI in the emergency setting.

Graphical Abstract

1. Introduction

Natriuretic peptide (NP) testing is of clinical value in the diagnosis of heart failure (HF) but also in patients with suspected acute coronary syndrome (ACS) [1,2]. The HF definition includes NP measurement interpretation and cutoffs for both ambulatory and acute settings. For HF, the N-terminal pro B-type NP (NT-proBNP) assay cutoff of ≥125 ng/L has been supported by other machine-learning based tools, further highlighting the role of NP testing using this cutoff [3]. Early decision-making and risk-stratification of suspected ACS using high-sensitivity cardiac troponin (hs-cTn) measurement has been reportedly improved with the incorporation of additional laboratory tests [1,4]. The clinical chemistry score (CCS) is an algorithm incorporating glucose measurement and the estimated glomerular filtration rate (eGFR) that has been demonstrated to improve the diagnostic and prognostic performance of hs-cTn in patients with possible ACS [4,5,6,7,8]. The glucose and hs-cTn cutoffs in the CCS have been validated with literature to support their use [9,10,11]. More controversial is the eGFR cutoff of 90 mL/min/1.73 m2 as the 60 mL/min/1.73 m2 cutoff has also been used to identify normal individuals [12]. Intriguingly, in patients with their measured GFR between ≥60 and <90 mL/min/1.73 m2 by either the iohexol plasma clearance or Cr51-EDTA plasma clearance methods the median concentration of NT-proBNP in this group (n = 148) was 121 ng/L [13]. As NT-proBNP is known to be cleared via the kidneys, using the 125 ng/L cutoff for NT-proBNP may serve not only as a marker of heart dysfunction but perhaps also as a surrogate of possibly reduced renal function [13]. Accordingly, we assessed the utility of NT-proBNP alone and in conjunction with glucose and hs-cTn using the ≥125 ng/L threshold (rather than eGFR) to determine its diagnostic performance for detecting a serious cardiovascular outcome in patients with suspected ACS.

2. Methods

2.1. Study Cohorts

We evaluated two different populations consisting of patients presenting with suspected ACS early after symptom-onset that had NT-proBNP measured in the presentation sample (Figure 1). In both cohorts, we obtained consent, blood for cardiac biomarker testing and demographic data. Details on storage and testing for NT-proBNP and the hs-cTn assays have been previously described [14,15]. Ethics approval was obtained by the Hamilton Health Sciences, McMaster University Research Ethics Board for Cohort-1 (#03-135) and the Hamilton Integrated Research Ethics Board (HiREB) for Cohort-2 (#08-427).
Briefly, Cohort-1 consisted of patients who consented to a study evaluating biomarkers for predicting serious cardiac outcomes (Research Ethics Board of Hamilton Health Sciences and McMaster University REB #03-135; the IMA study) [16]. In the month of September (2003), adult patients who presented with chest pain within 6 h of onset who consented to the study were enrolled. Eligibility criteria included: age 18 years or older, potential cardiac ischemia symptoms within 6 h from ED arrival and that the ED physician ordered cardiac troponin. Patients were excluded from the study if they were referred directly to the trauma or surgery teams; those in whom any of the study outcomes were obtained before the results of their first cardiac troponin results; patients who refused study participation or unable provide reliable contact information [14,16].
For Cohort-2 (from the RING study for Reducing the time Interval for identifying New Guideline defined MI in patients with suspected ACS in the ED; REB Project #08-427) [15,17] the design was similar as Cohort-1, with patient enrollment from December 2008 to April 2010. Specifically, patients who consented were included if: i. adult patient (>18 years of age) with onset of ACS symptoms within previous 6 h; ii. cardiac troponin ordered by ED physician; iii. consented to study and able to provide reliable contact for telephone follow up. Patients were excluded if: iv. ST elevation MI (STEMI); v. patient referred directly to surgery, or a trauma patient, or previous enrolment in RING study [15,17].

2.2. Outcomes

For both cohorts the outcomes were adjudicated with Cohort-1 using two physicians (emergency physician and a cardiologist) who independently evaluated all cases of suspected serious cardiac outcomes while blinded to cardiac biomarker data, with disagreements resolved by reaching a consensus opinion. Cohort-2 outcomes were also adjudicated by two physicians (ED physician and an internal medicine specialist) who independently adjudicated all outcomes and were blinded to the cardiac biomarker data. For both cohorts the composite outcome at 72 h (primary outcome) was used as previously described [14,15,16,17]. Briefly, for Cohort-1, the composite was death, MI, HF, serious arrhythmia and refractory ischemic cardiac pain (refractory angina), with the same outcomes used in Cohort-2 with the addition of revascularization (i.e., percutaneous intervention or coronary artery bypass graft), stroke and non-fatal cardiac arrest also included as part of the composite [18]. A secondary analysis was performed assessing MI alone in both cohorts.

2.3. Statistical Analysis

Data presented as counts, percentages, with non-parametric analyses used to describe distribution (i.e., median and interquartile range, IQR, with differences assessed via the Mann–Whitney U test and correlation by Spearman rho). Diagnostic estimates (benchmarks) included sensitivity (≥99%), specificity (≥90%), and positive (+LR ≥ 10) and negative (−LR ≤ 0.1) likelihood ratios as these estimates are not nearly as affected on prevalence as compared to predictive values [4,6,19]. For the calculation of the GuIDER score (Glucose, Injury and Dysfunction in the Emergency-setting for cardiovascular-Risk) the following algorithm was used: glucose ≥ 5.6 mmol/L = 1 point; NT-proBNP ≥ 125 ng/L = 1 point; with Abbott hs-cTnI concentration between 4–14 ng/L = 1 point/15–30 ng/L = 2 points/>30 ng/L = 3 points (Abbott GuIDER) and Roche hs-cTnT concentration between 8–18 ng/L = 1 point/19–30 ng/L = 2 points/>30 ng/L = 3 points (Roche GuIDER). The glucose and hs-cTn cutoffs were obtained from the CCS [4] with the 125 ng/L cutoff for NT-proBNP obtained from the proposed definition of HF and machine-based learning with population attributable risk percentage [2,3]. The GuIDER score ranged from 0 to 5 with the primary outcome (composite outcome) assessed based on each value. A secondary analysis consisted of assessing MI alone in the combined population designating the population into three groups: low-risk (GuIDER score 0 and 1), intermediate-risk (GuIDER score 2 and 3) and high-risk (GuIDER score 4 and 5) was also performed. ROC curve analyses were performed for NT-proBNP, hs-cTnI, hs-cTnT, Abbott GuIDER and Roche GuIDER with the DeLong test used to evaluate for differences between AUCs for each cohort for the primary outcome [20]. Analyses were performed using MedCalc® Statistical Software version 20.009 (MedCalc Software Ltd., Ostend, Belgium; https://www.medcalc.org; 2021) with p-values < 0.05 considered significant.

3. Results

There was no difference between the age of patients in Cohort-1 (n = 126, median (IQR) age = 59 years (49–72), age range = 23 to 93) versus Cohort-2 (n = 143, median (IQR) age = 60 years (49–70), age range = 24 to 90) (p = 0.78) with no difference between sexes in the cohorts (62% male in Cohort-1 versus 64% male in Cohort-2, p = 0.80) (Table 1). The number (percentage) of serious cardiac outcomes in Cohort-1 was 17 (13.5%) and 24 in Cohort-2 (16.8%) (p = 0.49). Pairwise comparison of ROC curves identified that there was a significant difference between AUCs for NT-proBNP versus the GuIDER scores in both cohorts (p < 0.05) (Figure 2). The AUCs for NT-proBNP were ≤ 0.75 with the 125 ng/L cutoff yielding a higher sensitivity (76% in Cohort-1 and 75% in Cohort-2) as compared to the 300 ng/L cutoff (59% in Cohort-1 and 58% in Cohort-2). The ≥5.6 mmol/L cutoff for glucose yielded a sensitivity of 88% in Cohort-1 and 83% in Cohort-2, with no correlation between glucose and NT-proBNP (rho = −0.04; p = 0.56).
Assessing the various GuIDER scores revealed that estimates of >99% sensitivity and >90% specificity were obtained in both cohorts, while only +LR and −LR exceeding the benchmarks in Cohort-2 (Table 2). Combining both cohorts and deriving the percentage of patients with and without serious cardiovascular outcomes indicated for Roche that 14% of the population would be low-risk (GuIDER score = 0) with none having serious outcomes. Conversely, 10% of the population would be labelled as high-risk (GuIDER score = 5) with 61% of this group having a serious cardiovascular outcome (Table 3). The same trends were observed for the Abbott GuIDER scores.
Secondary analyses for MI alone in the overall population assessing the percentage of patients that could be further classified as low-risk (GuIDER score 0 and 1), intermediate-risk (GuIDER score 2 and 3) and high-risk (GuIDERscore 4 and 5) revealed a prevalence of MI of 0%, 2% and 27% (Roche)/28% (Abbott) in the respective groups (Figure 3). The percentage of the ED population that would be classified as low-risk was 48%, intermediate-risk 31% and high-risk 21% using Roche hs-cTnT (similar trend for Abbott hs-cTnI). The diagnostic estimates for MI using the GuIDER score ≥ 2 as the cutoff yielded a sensitivity of 100% (95%CI: 80.5–100) for both Roche and Abbott with a specificity of 51.2% (95%CI:44.8–57.5, Roche) and 40.9% (95%CI: 34.7–47.2, Abbott).

4. Discussion

The present analyses indicates that the ≥125 ng/L cutoff for NT-proBNP is helpful for increasing the sensitivity for detection of a serious cardiovascular event and can inform clinicians on an appropriate cutoff for assessing patients with possible ACS. The lack of correlation between NT-proBNP and glucose is similar to previous findings of no correlation between glucose and cardiac troponin [21]. Together, these findings strengthen the inclusion of glucose with NT-proBNP and cardiac troponin as each of the biomarkers provide independent information.
By including NT-proBNP (using the established cutoff of 125 ng/L), with cardiac troponin and glucose to form the GuIDER score; patients at presentation can be immediately identified as being low- and high-risk. Combining these biomarkers may also help in further risk stratification for patients without possible ACS as has been recently shown using machine-based learning algorithms [3]. However, the one advantage of the GuIDER score over other algorithms is the limited number of variables and calculations needed to obtain such scores.
Limitations in the present study include the following, despite the improved prognostic performance of the GuIDER score. First, the cohorts used (i.e., patients enrolled from 2003 in Cohort-1 and from 2008 to 2010 in Cohort-2) for the score estimates are not a contemporary ED population and may not be representative of the generalized ED presentation populations, especially across different geographic locations and countries. Second, the pragmatism of using the GuIDER score at presentation as ~75% of the population would lie between low- and high-risk for the primary outcome, and would require additional testing and investigations before patient disposition. However, these estimates are similar to other laboratory-based algorithms [4,22]. Moreover, if the GuIDER score is applied for MI only nearly half of the population (48% with the Roche GuIDER score) could be rule-out for MI at presentation. Third, long-term outcomes would further support the utility of the GuIDER score, as has been demonstrated for the CCS [4,5,6,7,8]. Fourth, the data are from two small cohorts with adjudication for MI performed with non-hs-cTn assays. However, this is not uncommon as many studies that have developed and assessed algorithms have used non-hs-cTn assays for MI adjudication [23,24]. Fifth, large, multicenter studies across different geographical locations are needed to further define the utility of the GuIDER score over hs-cTn alone, as has been demonstrated for the CCS [4,5,6,7,8,22].
In conclusion, future studies assessing the GuIDER score should include larger and more diverse patient populations (which is a weakness for the present analyses), patients with and without ACS symptoms, with long-term follow-up, and a possible head-to-head comparison between the validated CCS versus the GuIDER score.

Author Contributions

Conceptualization, P.A.K.; methodology, P.A.K.; software, P.A.K.; validation, P.A.K. and A.W.; formal analysis, P.A.K.; investigation, P.A.K., S.H. and A.W.; resources, P.A.K., S.H. and A.W.; data curation, P.A.K. and S.H.; writing—original draft preparation, P.A.K.; writing—review and editing, M.K.H., S.E.M., S.H. and C.A., A.W.; visualization, P.A.K.; supervision, P.A.K.; project administration, P.A.K., S.H. and A.W.; funding acquisition, P.A.K., S.H. and A.W. All authors have read and agreed to the published version of the manuscript.

Funding

No additional funding was obtained for these analyses with previous CIHR funding for performing testing in both cohorts.

Institutional Review Board Statement

Ethics approval was obtained by the Hamilton Health Sciences, McMaster University Research Ethics Board for Cohort-1(#03-135) and the Hamilton Integrated Research Ethics Board (HiREB) for Cohort-2 (#08-427). Patient consent was obtained for both studies.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The studies were conducted before data sharing processes were in place, and thus individual data are not available. The data are not publicly available due to privacy.

Acknowledgments

Special thanks to the staff within the Clinical Research Laboratory and Biobank who performed the NT-proBNP testing.

Conflicts of Interest

Peter A. Kavsak has received grants/reagents/consultant/advisor/honoraria from Abbott Laboratories, Abbott Point of Care, Beckman Coulter, Ortho Clinical Diagnostics, Randox Laboratories, Roche Diagnostics, Quidel, Siemens Healthcare Diagnostics and Thermo Fisher Scientific. McMaster University has filed patents with PK and AW listed as an inventor in the acute cardiovascular biomarker field, in particular, a patent has been awarded in Europe (EP 3 341 723 B1) on aspects related to the data presented in this study “Method of determining risk of an adverse cardic event”. No other disclosures were reported.

References

  1. Collet, J.-P.; Thiele, H.; Barbato, E.; Barthélémy, O.; Bauersachs, J.; Bhatt, D.L.; Dendale, P.; Dorobantu, M.; Edvardsen, T.; Folliguet, T.; et al. 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur. Heart J. 2021, 42, 1289–1367. [Google Scholar] [CrossRef]
  2. Bozkurt, B.; Coats, A.J.; Tsutsui, H.; Abdelhamid, C.M.; Adamopoulos, S.; Albert, N.; Anker, S.D.; Atherton, J.; Böhm, M.; Butler, J.; et al. Universal definition and classification of heart failure: A report of the Heart Failure Society of America, Heart Failure Association of the European Society of Cardiology, Japanese Heart Failure Society and Writing Committee of the Universal Definition of Heart Failure. J. Card. Fail. 2021, 23, 352–380. [Google Scholar] [CrossRef]
  3. Segar, M.W.; Jaeger, B.C.; Patel, K.V.; Nambi, V.; Ndumele, C.E.; Correa, A.; Butler, J.; Chandra, A.; Ayers, C.; Rao, S.; et al. Development and Validation of Machine Learning-Based Race-Specific Models to Predict 10-Year Risk of Heart Failure: A Multi-Cohort Analysis. Circulation 2021, 143, 2370–2383. [Google Scholar] [CrossRef]
  4. Kavsak, P.A.; Neumann, J.; Cullen, L.; Than, M.; Shortt, C.; Greenslade, J.H.; Pickering, J.W.; Ojeda, F.; Ma, J.; Clayton, N.; et al. Clinical chemistry score versus high-sensitivity cardiac troponin I and T tests alone to identify patients at low or high risk for myocardial infarction or death at presentation to the emergency department. Can. Med. Assoc. J. 2018, 190, E974–E984. [Google Scholar] [CrossRef] [Green Version]
  5. Kavsak, P.A.; Cerasuolo, J.O.; Mondoux, S.E.; Sherbino, J.; Ma, J.; Hoard, B.K.; Perez, R.; Seow, H.; Ko, D.T.; Worster, A. Risk Stratification for Patients with Chest Pain Discharged Home from the Emergency Department. J. Clin. Med. 2020, 9, 2948. [Google Scholar] [CrossRef]
  6. Kavsak, P.A.; Cerasuolo, J.O.; Ko, D.T.; Ma, J.; Sherbino, J.; Mondoux, S.E.; Clayton, N.; Hill, S.A.; McQueen, M.; Griffith, L.E.; et al. Using the clinical chemistry score in the emergency department to detect adverse cardiac events: A diagnostic accuracy study. CMAJ Open 2020, 8, E676–E684. [Google Scholar] [CrossRef] [PubMed]
  7. Wildi, K.; Boeddinghaus, J.; Nestelberger, T.; Haaf, P.; Koechlin, L.; Ayala Lopez, P.; Walter, J.; Badertscher, P.; Ratmann, P.D.; Miró, Ò.; et al. External validation of the clinical chemistry score. Clin. Biochem. 2021, 91, 16–25. [Google Scholar] [CrossRef] [PubMed]
  8. Liu, L.; Mathias, A.; Kwong, T.; Worster, A.; Kavsak, P.A. Clinical chemistry score misses fewer deaths as compared to troponin T alone in a United States emergency department population. Clin. Biochem. 2021, 95, 91–92. [Google Scholar] [CrossRef]
  9. McQueen, M.J.; Kavsak, P.A.; Xu, L.; Shestakovska, O.; Yusuf, S. Predicting myocardial infarction and other serious cardiac outcomes using high-sensitivity cardiac troponin T in a high-risk stable population. Clin. Biochem. 2013, 46, 5–9. [Google Scholar] [CrossRef] [PubMed]
  10. Omland, T.; Pfeffer, M.A.; Solomon, S.D.; de Lemos, J.A.; Røsjø, H.; Šaltytė Benth, J.; Maggioni, A.; Domanski, M.J.; Rouleau, J.L.; Sabatine, M.S.; et al. Prognostic value of cardiac troponin I measured with a highly sensitive assay in patients with stable coronary artery disease. J. Am. Coll. Cardiol. 2013, 61, 1240–1249. [Google Scholar] [CrossRef] [Green Version]
  11. Selvin, E.; Lazo, M.; Chen, Y.; Shen, L.; Rubin, J.; McEvoy, J.W.; Hoogeveen, R.C.; Sharrett, A.R.; Ballantyne, C.M.; Coresh, J. Diabetes, Pre-Diabetes and Incidence of Subclinical Myocardial Damage. Circulation 2014, 130, 1374–1382. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Wu, A.H.; Christenson, R.H.; Greene, D.N.; Jaffe, A.S.; Kavsak, P.A.; Ordonez-Llanos, J.; Apple, F.S. Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion from the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory Medicine. Clin. Chem. 2018, 64, 645–655. [Google Scholar] [CrossRef]
  13. Bjurman, C.; Petzold, M.; Venge, P.; Farbemo, J.; Fu, M.L.; Hammarsten, O. High-sensitive cardiac troponin, NT-proBNP, hFABP and copeptin levels in relation to glomerular filtration rates and a medical record of cardiovascular disease. Clin. Biochem. 2015, 48, 302–307. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Kavsak, P.A.; Hill, S.A.; Supapol, W.B.; Devereaux, P.; Worster, A. Biomarkers for Predicting Serious Cardiac Outcomes at 72 Hours in Patients Presenting Early after Chest Pain Onset with Symptoms of Acute Coronary Syndromes. Clin. Chem. 2012, 58, 298–302. [Google Scholar] [CrossRef] [Green Version]
  15. Kavsak, P.A.; Worster, A.; You, J.J.; Oremus, M.; Shortt, C.; Phan, K.; Sohn, K.-Y.; Veljkovic, K.; Devereaux, P.J.; Hill, S.; et al. Ninety-Minute vs 3-h Performance of High-Sensitivity Cardiac Troponin Assays for Predicting Hospitalization for Acute Coronary Syndrome. Clin. Chem. 2013, 59, 1407–1410. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  16. Worster, A.; Devereaux, P.; Heels-Ansdell, D.; Guyatt, G.H.; Opie, J.; Mookadam, F.; Hill, S.A. Capability of ischemia-modified albumin to predict serious cardiac outcomes in the short term among patients with potential acute coronary syndrome. Can. Med. Assoc. J. 2005, 172, 1685–1690. [Google Scholar] [CrossRef] [Green Version]
  17. Pickering, J.W.; Greenslade, J.H.; Cullen, L.; Flaws, D.; Parsonage, W.; Aldous, S.; George, P.; Worster, A.; Kavsak, P.A.; Than, M.P. Assessment of the European Society of Cardiology 0-Hour/1-Hour Algorithm to Rule-Out and Rule-In Acute Myocardial Infarction. Circulation 2016, 134, 1532–1541. [Google Scholar] [CrossRef]
  18. Shortt, C.; Phan, K.; Hill, S.A.; Worster, A.; Kavsak, P.A. An approach to rule-out an acute cardiovascular event or death in emergency department patients using outcome-based cutoffs for high-sensitivity cardiac troponin assays and glucose. Clin. Biochem. 2015, 48, 282–287. [Google Scholar] [CrossRef]
  19. Gallagher, E. Clinical utility of likelihood ratios. Ann. Emerg. Med. 1998, 31, 391–397. [Google Scholar] [CrossRef]
  20. Delong, E.R.; Delong, D.M.; Clarke-Pearson, D.L. Comparing the Areas under Two or More Correlated Receiver Operating Characteristic Curves: A Nonparametric Approach. Biometrics 1988, 44, 837. [Google Scholar] [CrossRef]
  21. Kavsak, P.A.; Shortt, C.; Ma, J.; Clayton, N.; Sherbino, J.; Hill, S.A.; McQueen, M.; Mehta, S.R.; Devereaux, P.; Worster, A. A laboratory score at presentation to rule-out serious cardiac outcomes or death in patients presenting with symptoms suggestive of acute coronary syndrome. Clin. Chim. Acta 2017, 469, 69–74. [Google Scholar] [CrossRef] [PubMed]
  22. Kavsak, P.A.; McRae, A.; Vatanpour, S.; Ismail, O.Z.; Worster, A. A Multicenter Assessment of the Sensitivity and Specificity for a Single High-Sensitivity Cardiac Troponin Test at Emergency Department Presentation for Hospital Admission. J. Appl. Lab. Med. 2019, 4, 170–179. [Google Scholar] [CrossRef]
  23. Neumann, J.; Twerenbold, R.; Ojeda, F.; Sörensen, N.A.; Chapman, A.; Shah, A.; Anand, A.; Boeddinghaus, J.; Nestelberger, T.; Badertscher, P.; et al. Application of High-Sensitivity Troponin in Suspected Myocardial Infarction. N. Engl. J. Med. 2019, 380, 2529–2540. [Google Scholar] [CrossRef] [PubMed]
  24. Kavsak, P.A.; Hewitt, M.K.; Mondoux, S.E.; Cerasuolo, J.O.; Ma, J.; Clayton, N.; McQueen, M.; Griffith, L.E.; Perez, R.; Seow, H.; et al. Diagnostic Performance of Serial High-Sensitivity Cardiac Troponin Measurements in the Emergency Setting. J. Cardiovasc. Dev. Dis. 2021, 8, 97. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Flow diagram of cohorts used in this study.
Figure 1. Flow diagram of cohorts used in this study.
Jcdd 08 00106 g001
Figure 2. ROC curves for the primary composite outcome for the different biomarkers and algorithms.
Figure 2. ROC curves for the primary composite outcome for the different biomarkers and algorithms.
Jcdd 08 00106 g002
Figure 3. Percentage of ED population (both Cohort-1 and Cohort-2; n = 269) classified as low-risk (GuIDER score 0 and 1), intermediate-risk (GuIDER score 2 and 3) and high-risk (GuIDER score 4 and 5) and the prevalence of MI in these three groups.
Figure 3. Percentage of ED population (both Cohort-1 and Cohort-2; n = 269) classified as low-risk (GuIDER score 0 and 1), intermediate-risk (GuIDER score 2 and 3) and high-risk (GuIDER score 4 and 5) and the prevalence of MI in these three groups.
Jcdd 08 00106 g003
Table 1. Baseline characteristics of Cohort-1 and Cohort-2. Data presented as counts, percentages and median (IQR).
Table 1. Baseline characteristics of Cohort-1 and Cohort-2. Data presented as counts, percentages and median (IQR).
VariableCohort-1 (n = 126)Cohort-2 (n = 143)
Age, Years59 (49–72)60 (49–70)
Sex, Male78 (62%)92 (64%)
Presenting with Chest Pain107 (85%)133 (93%)
Glucose, mmol/L6.2 (5.4–7.4)6.0 (5.2–7.8)
Glucose ≥ 5.6 mmol/L88 (70%)94 (66%)
NT-proBNP, ng/L138 (38–504)136 (33–325)
NT-proBNP ≥ 125 ng/L 67 (53%)76 (53%)
hs-cTnT, ng/L5 (<3–16)7 (<3–17)
hs-cTnT > 14 ng/L33 (26%)44 (31%)
hs-cTnI, ng/L7 (4–15)2 (<1–10)
hs-cTnI > 26 ng/L19 (15%)23 (16%)
Table 2. Sensitivity, specificity and likelihood ratios for the GuIDER scores in Cohort-1 and Cohort-2 for primary outcome.
Table 2. Sensitivity, specificity and likelihood ratios for the GuIDER scores in Cohort-1 and Cohort-2 for primary outcome.
Roche GuIDER Scores in Cohort-1 (AUC = 0.82)
CriterionSensitivity95% CISpecificity95% CI+LR95% CI−LR95% CI
>010080.5–100.015.69.4–23.81.181.1–1.30.00
>188.263.6–98.554.144.3–63.71.921.5–2.50.220.06–0.8
>276.550.1–93.272.563.1–80.62.781.9–4.20.320.1–0.8
>364.738.3–85.886.278.3–92.14.702.6–8.50.410.2–0.8
>447.123.0–72.292.786.0–96.86.412.8–14.80.570.4–0.9
Roche GuIDER Scores in Cohort-2 (AUC = 0.85)
CriterionSensitivity95% CISpecificity95% CI+LR95% CI−LR95% CI
>010085.8–100.016.810.6–24.81.201.1–1.30.00
>195.878.9–99.956.346.9–65.42.191.8–2.70.0740.01–0.5
>275.053.3–90.275.666.9–83.03.082.1–4.60.330.2–0.7
>358.336.6–77.986.679.1–92.14.342.5–7.70.480.3–0.8
>437.518.8–59.497.592.8–99.514.874.3–50.90.640.5–0.9
Abbott GuIDER Scores in Cohort-1 (AUC = 0.86)
CriterionSensitivity95% CISpecificity95% CI+LR95% CI−LR95% CI
>110080.5–100.033.024.3–42.71.491.3–1.70.00
>288.263.6–98.564.254.5–73.22.471.8–3.30.180.05–0.7
>370.644.0–89.785.377.3–91.44.812.8–8.30.340.2–0.7
>447.123.0–72.294.588.4–98.08.553.4–21.60.560.4–0.9
Abbott GuIDER Scores in Cohort-2 (AUC = 0.88)
CriterionSensitivity95% CISpecificity95% CI+LR95% CI−LR95% CI
>010085.8–100.015.19.2–22.81.181.1–1.30.00
>195.878.9–99.955.546.1–64.62.151.7–2.70.0750.01–0.5
>275.053.3–90.279.070.6–85.93.572.4–5.40.320.2–0.6
>366.744.7–84.492.486.1–96.58.814.4–17.60.360.2–0.6
>433.315.6–55.398.394.1–99.819.834.5–87.70.680.5–0.9
Table 3. Percentage of primary outcome per the GuIDER scores using both Abbott hs-cTnI and Roche hs-cTnT for the combined cohorts.
Table 3. Percentage of primary outcome per the GuIDER scores using both Abbott hs-cTnI and Roche hs-cTnT for the combined cohorts.
Abbott GuIDER Score012345
Outcome01751216
No Outcome27756239178
% Outcome0%1%10%11%41%67%
n (total = 269)277669442924
% of Patients10%28%26%16%11%9%
Chi-Square for Trend p < 0.001
Roche GuIDER Score012345
Outcome0376817
No Outcome378943282011
% Outcome0%3%14%18%29%61%
n (total = 269)379250342828
% of Patients14%34%19%13%10%10%
Chi-Square for Trend p < 0.001
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Kavsak, P.A.; Mondoux, S.E.; Hewitt, M.K.; Ainsworth, C.; Hill, S.; Worster, A. Can the Addition of NT-proBNP and Glucose Measurements Improve the Prognostication of High-Sensitivity Cardiac Troponin Measurements for Patients with Suspected Acute Coronary Syndrome? J. Cardiovasc. Dev. Dis. 2021, 8, 106. https://doi.org/10.3390/jcdd8090106

AMA Style

Kavsak PA, Mondoux SE, Hewitt MK, Ainsworth C, Hill S, Worster A. Can the Addition of NT-proBNP and Glucose Measurements Improve the Prognostication of High-Sensitivity Cardiac Troponin Measurements for Patients with Suspected Acute Coronary Syndrome? Journal of Cardiovascular Development and Disease. 2021; 8(9):106. https://doi.org/10.3390/jcdd8090106

Chicago/Turabian Style

Kavsak, Peter A., Shawn E. Mondoux, Mark K. Hewitt, Craig Ainsworth, Stephen Hill, and Andrew Worster. 2021. "Can the Addition of NT-proBNP and Glucose Measurements Improve the Prognostication of High-Sensitivity Cardiac Troponin Measurements for Patients with Suspected Acute Coronary Syndrome?" Journal of Cardiovascular Development and Disease 8, no. 9: 106. https://doi.org/10.3390/jcdd8090106

APA Style

Kavsak, P. A., Mondoux, S. E., Hewitt, M. K., Ainsworth, C., Hill, S., & Worster, A. (2021). Can the Addition of NT-proBNP and Glucose Measurements Improve the Prognostication of High-Sensitivity Cardiac Troponin Measurements for Patients with Suspected Acute Coronary Syndrome? Journal of Cardiovascular Development and Disease, 8(9), 106. https://doi.org/10.3390/jcdd8090106

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop