Next Article in Journal
GHz Superconducting Single-Photon Detectors for Dark Matter Search
Previous Article in Journal
A Sustainable Slit Jet FTIR Spectrometer for Hydrate Complexes and Beyond
Previous Article in Special Issue
Luminescence Response and Quenching Models for Heavy Ions of 0.5 keV to 1 GeV/n in Liquid Argon and Xenon
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST

by
Matthew Szydagis
1,*,
Grant A. Block
1,2,
Collin Farquhar
1,3,4,
Alexander J. Flesher
5,
Ekaterina S. Kozlova
6,7,
Cecilia Levy
1,
Emily A. Mangus
1,8,
Michael Mooney
5,
Justin Mueller
5,
Gregory R. C. Rischbieter
1 and
Andrew K. Schwartz
1,9
1
Department of Physics, University at Albany SUNY, 1400 Washington Ave., Albany, NY 12222-0100, USA
2
Department of Physics, Applied Physics and Astronomy, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
3
The College of St. Rose, Albany, NY 12203, USA
4
ANDRO Computational Solutions, LLC, Rome, NY 13440, USA
5
Department of Physics, Colorado State University, Fort Collins, CO 80523, USA
6
Institute for Theoretical and Experimental Physics Named by A.I. Alikhanov of National Research Centre “Kurchatov Institute”, 117218 Moscow, Russia
7
Moscow Engineering Physics Institute (MEPhI), National Research Nuclear University, 115409 Moscow, Russia
8
Northrop Grumman, Goddard Space Flight Center, Greenbelt, MD 20771, USA
9
Department of Physics and Astronomy, Rutgers University, Piscataway, NJ 08854, USA
*
Author to whom correspondence should be addressed.
Instruments 2021, 5(1), 13; https://doi.org/10.3390/instruments5010013
Submission received: 1 December 2020 / Revised: 19 February 2021 / Accepted: 5 March 2021 / Published: 18 March 2021
(This article belongs to the Special Issue Light Production and Detection in Noble Liquid Detectors)

Abstract

:
Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (weakly interacting massive particles WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the application of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.

1. Introduction

The noble elements, especially xenon (Xe) and argon (Ar) as liquids, have been instrumental in the field of dark matter (DM) direct detection, focused on identifying the missing ∼25% of the mass–energy content of the universe. They have also been key for neutrinos. In the former case, Xe [1,2,3] and Ar [4,5] are each used by distinct large collaborations, and used both to search for continuous spectra, such as the approximate falling exponential expected from the traditional weakly interacting massive particle (WIMP) [6], or monoenergetic peaks expected from dark photons or bosonic super-WIMPs [7]. In the latter case, argon is used in long- and short-baseline oscillation studies [8,9] and xenon in the search for neutrinoless double-beta decay, as either a liquid [10] or a gas [11]. In all of these cases, there is a clear need for high accuracy and high precision in energy reconstruction and good energy resolution in order to identify signals and backgrounds, and calibrate the detectors. Combining the data with high-fidelity Monte Carlo (MC) simulations can aid in this task. Xe and Ar produce scintillation light, and when an external electric field is applied then ionization electrons can be extracted as well. In a dual-phase time projection chamber (TPC), a gas stage converts the ionization into a secondary scintillation pulse [12] while a single-phase TPC reads out the charge directly [13,14]. Energy scales have been based in the past and present on the scintillation, on the ionization, and on their combination.
In this work, we will be reviewing each of these methods, contrasting them and enumerating their strengths and weaknesses, in terms of the mean, median, and mode (e.g., Gaussian peak centroid) of reconstructed energy best matching the true energy (MC truth energies and/or monoenergetic calibration peaks), the width, and the shape (symmetry). Multiple types of particles will be covered, addressing scattering from atomic electrons and nuclei, electron recoil (ER) and nuclear recoil (NR) respectively, and recoil energies from sub-keV up to GeV, from DM-WIMP-induced NR or coherent elastic neutrino nucleus scattering (CE ν NS), to neutrino-induced ER. The summaries in each section make idealized recommendations, with detector-dependent caveats, for future DM/neutrino projects.

2. Methods

2.1. General

Examples of usages of each of the possible energy scale definitions are taken from empirical data wherever possible, but also compared to the Noble Element Simulation Technique (NEST), which is also used by itself where data are lacking. NEST is a global, experiment- and detector-independent MC framework that allows simulation of scintillation and ionization yield averages and resolutions as functions of incoming or deposited energy, electric field, and interaction type [15].
The values of detector-specific parameters also need to be known in order to permit NEST to simulate the detectors effects for a specific experiment. The most important numbers are g 1 , g 2 , and the magnitudes of the drift and extraction electric fields, if applicable. g 1 and g 2 are respectively defined as the gains of the primary and secondary scintillation channels, the latter from ionization (again, only if applicable). g 1 is always between 0 and 1, and is an efficiency which combines the quantum efficiencies of one’s photo-sensors with the geometric light collection efficiency (It is also known as the photon detection efficiency). It can include or exclude, depending on choice of units, the probability for certain photon detectors (especially in the vacuum ultraviolet or VUV) to produce more than one photoelectron (phe) for a single incoming photon [16]. Typical values across all experiments using Xe or Ar are ∼0.05–0.20 phe per photon [17,18,19,20,21,22,23]. g 2 is a combination of the electron extraction efficiency for a two-phase TPC with the gas gain, i.e., the number of photons produced per extracted electron times the photon detection efficiency in the gas phase [24]. A typical value is ∼10–30 phe per electron.
Some photons, especially in the ultraviolet range, carry sufficient energy in order to generate more than one phe per incident photon, in the photocathodes of certain photon detectors, and stochastically, not consistently. The definition of the unit “photons detected” or “detected photons” or phd for short is simply phe (alternatively called PE by some authors) divided by (1 + p 2 e ), where p 2 e is the probability of producing two (photo)electrons, typically 0.1–0.3, depending on the manufacturer, temperature, and individual phototube: p h d = p h e / ( 1 + p 2 e ) , while a similar translation applies to the g 1 . While taking this effect into account is ideal for the resolving of peaks and achieving the best possible background discrimination for one’s final analyses, the convention for how the final results are plotted varies by experimental collaboration, making comparisons more difficult (the XENON and DARWIN groups prefer phe or PE but LUX and LZ prefer phd). PIXeY’s 2-phe probability was reported as 17.5% [25], implying that division by 1.175 would convert phe into phd.
We define N p h and N e , as the original numbers of photons and electrons generated from an interaction site, determined by MC truth (integer) or empirical reconstruction (float). N q is their sum. In data, or advanced MC, including detector effects like finite detection efficiencies not just mean yields: N p h = S 1 c / g 1 and N e = S 2 c / g 2 . S1 and S2 are the primary and secondary scintillation pulse areas. Subscript ‘c’ denotes correction, primarily for XYZ-position effects, as light collection efficiency may depend significantly on 3D position, especially in a large-scale detector [26]. The energy dependence is intrinsic to the element, unrelated to the position inside a particular detector. It is thus useful to also define two additional terms, L y and Q y , which respectively refer to the N p h and N e per unit of energy.
Our default guiding formula, at least for combined energy-scale reconstruction, is therefore:
E = N q W q L ( E ) = ( N p h + N e ) W q L ( E ) = ( S 1 c g 1 + S 2 c g 2 ) W q L ( E ) .
L is Lindhard factor, quantifying E “lost” (if a detector cannot see phonons) into heat (atomic motion) instead of observable quanta. Called also “quenching” historically, that word is not precise: quanta are not being quenched per se but are not being created ab initio, unlike in quenching by impurities or ionization density. It depends on E, making Equation (1) circular. Circularity can be avoided by a good MC model like NEST, and by quasi-monoenergetic NR data, as in the LUX D-D analysis [27]. For ER, L is taken to be 1.0, not implying no heat loss but an approximately constant loss as a function of E that can be “rolled into” the definition of work function, essentially raising it. For neutrino experiments, E depositions are tracks not point-like, and d E / d x (energy loss per unit of distance) is more relevant.
The L quantifies the effectiveness of an initial NR at producing more elastic recoils as secondary interactions not inelastic, i.e., atomic excitations/ionizations. It can be modeled in other/better ways than Lindhard’s, expected to break down at low Es, as seen in Si/Ge [28]. It should not be confused with L e f f used for S1 [17,29,30,31] at zero field, and not accounting for 57 Co 122 keV γ -rays not being representative of even ER yields, at different Es [32,33]. ( L e f f was the ratio of NR to ER light yields).
L ( E ) can be thought of as merging the scintillation and ionization efficiencies (whereas L e f f is only the scintillation efficiency, again compared to ER’s L y ). However, as with the word quenching, it is better to avoid this terminology; it can be confused with the efficiency set in DAQ and/or data analysis, by for example requiring a certain number of photomultiplier tubes (PMTs) to fire to count an S1 (2-fold coincidence for example in LUX, a much later example using ER, where this coincidence requirement, g 1 ≪ 1, and other effects lead to a threshold). The E within the L-factor is the true energy of a nucleus recoiling from a neutron (or ν coherently, or DM hopefully in the future). When quoting imperfect reconstructed energy using Equation (1), with 0 < L < 1 , the standard unit is keV n r to contrast with the unit defined assuming L = 1 for ER earlier: keV e e .
The subscript ‘q’ indicates that the W value is not based on scintillation or ionization alone. W q is effectively an average over microphysical processes producing excited/ionized atoms. We do not describe them, as they are within other works [34,35,36], nor establish NEST’s accuracy here, using it for convenience where data are lacking. The physical details and how NEST captures them are beyond the scope of this paper. In this section, in particular, we summarize established methods [32,37].
At zero field, one only has access to the S1, and for specialized searches for (sub-)GeV DM [38,39] to only S2 due to the low energies involved, as the ionization, i.e., charge yield is typically larger and easier to detect, even as E goes to zero. The formula correspondingly morphs into one of these:
E = N p h L y = S 1 c g 1 1 L y ( E , E )
or
E = N e Q y = S 2 c g 2 1 Q y ( E , E ) ,
where L y = N p h / E and Q y = N e / E are functions of energy E and field E . Each differ for ER and NR; they are not fixed as W q was, for ER. The challenge of E reconstruction increases via an inherent non-linearity, e.g., 2× the E does not mean 2× the light or charge as it does with N q at least for ER. When considering resolution, this causes deviation from the Poisson expectation of 1 / E improvement with higher E, which only applies for the combined scale ( 1 / N q ). A more general power law then works best [40,41,42]. In liquid xenon (LXe), the fact L y is not flat vs. E was first demonstrated by Obodovskii and Ospanov [43] for ER (implying for fixed W that ER Q y is also not constant) and by Aprile et al. for NR Q y [44,45] but not well known in the DM field for ER background at least until much later publications [33,46]. In the case of experiments like EXO (0 ν β β decay) and DUNE (long-baseline ν ’s) using Xe/Ar, only the first half of (3) applies, as they measure Q directly in liquid using wire readout planes, instead of in gas. In addition, for combined E (Equation (1)) especially, S2 can be defined using a subset of photon sensors instead of all. A cylindrical TPC typically has two arrays, one at each end. The bottom one alone (subscript ‘b’ for differentiation from total S2) may be used for E reconstruction as in [47] to adjust for light loss created by inoperative phototubes in the gas, or saturation. Lastly, g 1 can be vastly smaller in kiloton-scale ν experiments, unlike the range quoted earlier for DM: they rely on Q y .
For the purposes of reproducibility, we note that all of the work presented here uses the latest stable NEST release at time of writing: Version 2.2.0 [48] for which the default detector parameter file is designed to mimic the first science run of LUX [49] but which we modify as needed to reproduce other experiments, focusing again on g 1 , g 2 , and drift electric field E as the three most salient inputs.

2.2. NEST-Specific Details

The main assumptions utilized in NEST to reproduce efficiencies are briefly explained below.
  • A Fano-like factor sets variation in total quanta, with a binomial distribution for differentiating excitons/ions (inelastic scattering). In LXe, it is not sub-Poissonian as in GXe, as experimentally verified in each phase [50].
  • Recombination fluctuations [51,52,53]: the “slosh” of N p h vs. N e caused by recombination probability for ionization e s, which may either recombine to make more S1, or escape to make S2. These are worse (i.e., larger) than expected naïvely (non-binomial). This is distinct from Fano factor, and canceled by combined E.
The above are general, but the below depend on the detector, all combining into the final efficiency.
  • g 1 is used to define a binomial distribution for the S1 photon detection efficiency with < S 1 > = g 1 N p h .
  • For an S1 to be above the trigger threshold, most experiments require that O(0.1) phe must be observed in N PMTs for N-fold coincidence, where usually N = 2 or 3, within a coincidence window, of 50–150 ns, requiring a basic timing model for singlet and triplet states and photon propagation time. The 2 or 3-fold coincidence prevents triggering on photo-sensor dark counts. Baseline noise O(0.1) phe is also modeled.
  • The pulse areas of single phe are assumed to follow a truncated (negative phe are not possible) Gaussian distribution, with O(10%) resolution differing by photon-sensor, but a detector-wide average is used for NEST, as an approximation. If single phe detection efficiency is reported, it can be used instead of a threshold applied to a Gaussian random number generator, thus taking non-Gaussianity and other detector-specific idiosyncrasies into account. This and others numbers are collected from arXiv, publications, and theses.
  • Drifting, diffusing electrons are removed via an exponential electron lifetime, and are assumed to follow a binomial extraction efficiency, while the number of photons produced per surviving extracted electron depends on the gas density, electroluminescence electric field, and gas gap size, in a 2-phase TPC [54,55].
  • A special Fano factor, typically also >1 for S2 accounts for non-Poissonian behavior, due for example to grid wire sagging. A value of 2–4 is normal [56]. S2 photons experience a similar binomial photon detection efficiency as S1 photons, moving along from photons to phe (for S2, from electrons to photons to phe). A raw, total S2 threshold O(100) phe removes the lowest-energy events, to avoid few-electron backgrounds [57].
  • S1 and S2 XYZ variation is simulated in NEST if provided in analytical form, then realistically corrected back out, based upon finite position resolution, not MC truth positions, thus allowing not only for correct means but correct widths. (Z or drift correction applies only to S1, handled for S2 by the electron lifetime.)
  • N p h falls while N e rises with drift field in anti-correlated fashion, and fields can be non-uniform.
A final step of noise is applied as an empirical smearing to the S1 and S2 pulse areas to match realistic experimental data; however, the above lists capture the vast majority of fluctuations that can shift the low-energy efficiency higher or lower. Additional noise is typically at a level of O(1%) from unknown sources, but likely due to position correction imperfection and other analysis-specific effects, discussed in [24,36,58]. This is uncorrelated noise, as it is applied separately to S1 and S2, while the variation induced by the Fano factor (Step 1 in first list) is correlated “noise” due to raising S1 and S2 together, and the recombination fluctuations constitute anti-correlated noise, as in raising S1 they lower S2, and vice versa. All fluctuations can move events above and/or below nominal thresholds.
All steps above are uncertain especially when it comes to a simulation software package such as NEST. It would be infeasible to discuss and address all uncertainties. Thus, we will mention only one that is often largest. The N e x and N i , followed by N p h and N e , produced at Step (1.) in the first list above, depend on particle, energy, field, density via temperature and pressure, and phase, and at the lowest energies (sub-keV especially, and in particular for NRs) there is a non-negligible systematic uncertainty from the values assumed for the average yields ( L y and Q y ) which are always the first step in NEST modeling. For ER Q y , the discrepancy between different data sets and models is as much as 20% below 1 keV, as illustrated by contrasting NEST [58] with PIXeY 37 Ar data [59], X-rays in LUX [60], and 3 H in XENON100 [61]. L y = 0 in NEST for sub-keV ER but not in XENON models, which thus predict higher efficiency [42]. The 50% efficiency point typically is the “E threshold.”
For the purposes of this review paper, what is of greatest importance is that the assumptions, of the default NEST yield models, are not varied, when comparing different energy reconstruction techniques, so that at the very least a robust comparison can be made among them. That being said, we stress the accuracy of NEST in reproducing efficiency even for publications where the authors have no access to the original data is high (not only LUX [62]). XENON1T is an excellent example [58].

3. Results

Xe is examined first (ER then NR) followed by Ar. For Xe, the present-day relevant experiments seeking DM for whom this review is most pertinent include: LZ (LUX-ZEPLIN), XENON, and PandaX. The use of LAr is divided, present and past, across DEAP (Dark matter Experiment using Argon Pulse-shape discrimination), CLEAN (Cryogenic Low Energy Astrophysics with Noble liquids), ArDM (Argon Dark Matter), and DarkSide (first two single-phase and zero field, latter two dual-phase and non-zero electric field) on the DM front, and DUNE (Deep Underground Neutrino Experiment), MicroBooNE, ArgoNeuT (Argon Neutrino Test project), ICARUS (Imaging Cosmic And Rare Underground Signals), plus many others, studying neutrinos. Enriched LXe is used by nEXO (next Enriched Xenon Observatory), a TPC but only one phase, and NEXT (Neutrino Experiment with a Xenon TPC, GXe) for the hunt for 0 ν β β decays. α s and heavier ions different from the medium, with properties like additional quenching, modify the E reconstruction formulae, but we will only focus on basic ER and NR; other recoil types are already covered elsewhere [15,63].

3.1. Liquid Xenon Electron Recoil

3.1.1. Low Energy: keV-scale (Dark Matter Background, Signal) Basic Reconstruction of Mono-E Peaks

The term electron recoil or ER refers to interactions with the electron cloud, such as from beta emissions and the Compton scattering or photoabsorption of gamma rays. In a WIMP search, ER is the primary background, but in a more general DM (or exotic physics) search a monoenergetic peak or even continuous ER spectrum can be the signal [64]. To illustrate the differences among the S1-only, S2-only, or Q-only, and combined-E scales for reconstruction the first example is the lowest-energy ER calibration peak available at time of writing for LXe where we have S1 and S2 still: the electron capture decay of 37 Ar at 2.82 keV. It is also a timely example due to the recent XENON1T ER result [42,58].
While this E is not often in the regime of efficiency drop, we do address it in this section. Our source of data here was the seminal work led by McKinsey et al. at Yale/Berkeley [59] who constructed a small-scale calibration chamber, PIXeY, with g 1 = 0.097 ± 0.007 phe/photon and g 2 = ( 0.78 ± 0.05 ) × 36.88 = 28.77 ± 1.85 phe/ e (extraction efficiency times the single- e pulse area). To replicate PIXeY precisely with NEST in Figure 1, we use g 1 = 0.1015 , g 2 = 30.65 , only 0.6–1.0 σ higher. We studied only 198 V/cm. W q was taken to be 13.5 eV, between Dahl [36] and neriX [65] measurements. In all plots, keV e e means reconstructed energy ( e e standing for electron equivalent, for when NR is translated into this scale) as opposed to MC truth, or a known single E from a peak, reported in keV sans subscript.
While lower-E calibrations exist than 2.8 keV, this is the lowest where S1 and S2 are identified separately. Others become S2-only [60]. Figure 1a demonstrates that the S1-only scale, used primarily on XENON10 [29] and continuing on in a subset of XENON100 analyses [66], performs the poorest, with an energy resolution σ / μ of 38.63% for data (38.59 NEST) in red. (Both XENON10/100 had similar g 1 s to PIXeY, but slightly lower, at ∼0.07.) Values in parentheses following values from data now are for NEST, on to subsequent pages, in the style of A (B). An S1 basis is further complicated by non-linearity. Next, in Figure 1b the S2 only is plotted, leading to an 11.65% (12.20) resolution. While we see later that the combined scale, by including all available information, is typically best at higher energies, this is not the case any longer at keV-scale energies, as (c) indicates. Combined resolution is 15.84% (15.51). This is caused by data from these Es being comprised of upward S1 fluctuations above nominal S1 threshold, due to finite g 1 . An experimenter measures the right tail of S1s essentially.
Nevertheless, it is possible to mitigate S1 effects, still include S1 in the E calculation, and obtain the best possible resolution. One way is to fit a skew Gaussian (parameters explained in [53,58]):
y = A e ( x ξ ) 2 2 ω 2 [ 1 + e r f ( α x ξ ω 2 ) ]
While this has been done for bins in S2 vs. S1 [53] and once for combined E [58], it is most effective for S1: see the improvement in Figure 1a (blue vs. red). A skew fit, while including an error function e r f and similar to the equation used in [59] that should account for triggering, still misses some points, as keV-level S1 becomes non-Gaussian and non-symmetric due to trigger efficiency dropping below 100%. In plot (c) however, the reduced χ 2 drops from O(100) for both data and NEST to 2.6 for the 1.5–5 keV e e range, still too high due to features in the data not captured even by a skew-normal fit, but more sensible. Asymmetries arise from both thresholding bias [27] and microphysics [53,58].

3.1.2. More Advanced Energy Reconstruction Strategies, from keV to MeV Scales, and Resolution

A superior mitigation strategy can be found upon realization that the optimal weights for the S1 and S2 pulse areas are no longer simply g 1 and g 2 at the O(keV) scale. We can recast this statement in terms of the (n)EXO-style combined-energy scale first developed by Conti [51]: instead of using a g 1 and g 2 , it defines what is known as an angle of anti-correlation for summing S1 plus Q or S2. As energy decreases, the angle becomes energy-dependent instead of being fixed as t a n 1 ( g 2 / g 1 ) [40] and thus no longer respecting “perfect” anti-correlation of quanta, with N p h and N e always summing to N q = E / W q . Note there is no evidence of anti-correlation breakdown at least in LXe above 1 keV: this effect is caused by inability to reconstruct N p h well in data due to dropping S1 efficiency, as first suggested by Szydagis (2012) and first publicly applied in the PIXeY 37 Ar paper [59].
E = ( w 1 ( E ) S 1 c g 1 + S 2 c g 2 ) W q × w 2 ( w 1 )
Parameter w 1 decreases the weight assigned to S1 for low Es, countering thresholding; one could increase the S2 weight, but this is equivalent. Multiplying S1 by one weight, and S2 by another would be redundant. Instead, one weight is applied to S1, and a second weight w 2 to the formula as a whole to bring the average of the energy being reconstructed back to the correct mean after the shift caused by adding w 1 , while simultaneously correcting for any efficiency bias near the S1 and/or S2 thresholds. It is not technically independent then, thus written in Equation (5) as a function of w 1 , which itself is a function of energy. To avoid a circular reference, Equation (1) can be used to determine its energy dependence, for use in 5, and the process can be iterative, defining E after E , etc. Knowledge of the proper weights a priori is achievable via MC.
Without an MC like NEST tuned on earlier calibration data, it is possible to empirically determine the two weights by calibrating an experiment with monoenergetic peaks ( e capture, X-ray, gamma-ray). In the case of PIXeY’s 37 Ar measurement, the values which minimize the width of the Ar peak in reconstructed energy (optimum resolution) are w 1 = 0.19 and w 2 = 1.38 (NEST: 0.23, 1.35). Looking back at Figure 1d, the very positive effect of applying Equation (5) is evident: the resolution is 10.60% (10.68%) close to S2-only (b) but a factor of ∼1.5 improvement over (c) the more traditional “plain” combined scale. Moreover, the Gaussian centroid has dropped from 3.03 keV e e (again, higher because of triggering on high-S1 fluctuations) to 2.83 (2.81) much closer to the true value of 2.82, while the asymmetry in the histogram has nearly vanished, with the best-fit skew Gaussian possessing a positive (right-hand) skewness parameter α < 1 (compared to ∼2–2.5 in (c), which used Equation (1)). While it is not possible to remove all of the skew, as some is intrinsic (from the physics of recombination probability) [53], in panel (d) the Gaussian (red) and skew (blue) fits are nearly indistinguishable (unlike in plot 1c).
This technique, essentially equivalent to inverse-variance weighting, is not widespread for DM, although found in [25]. From its inception, LUX has relied on Equation (1), i.e., plot 1c’s method, but a Profile Likelihood Ratio (PLR) analysis effectively takes into account energy bias by relying on NEST to produce non-analytic 2D PDFs for both background and signal, relying on MC truth energy converted to S1 and S2, not reconstructed energy [67]. XENON’s own MCs for its PLR perform the same function, taking MC truth and/or calibrations as input, and outputting (S1, S2) PDFs mimicking data [68].
Many possible enhancements exist, like Maximum Likelihood [69] and Machine Learning [70]. These can take more than S1 and S2 into account, e.g., bypassing calibrated 3D corrections, feeding raw S1 and S2 plus positions into an artificial neural network (ANN) or Boosted Decision Tree (BDT) from which XYZ dependence emerges, given sufficient training. Ernst and Carrara suggest that it is possible to determine how much is sufficient [71]. Some examples of additional training variables include the E-dependent S1 pulse shape, usable given sufficient statistics [54,72], as well as breakdown of pulse areas into top and bottom arrays, capitalizing on anti-correlation of top vs. bottom light similar to that of S1 vs. S2, as used early on LUX [73], good for detectors sans S2 (0 V/cm). However, idiosyncrasies of individual detectors make it difficult to review such methods, which still rely on S1 and S2 as the two most important variables regardless. ANNs/BDTs are best trained by a combination of S1s and S2s from data and MC, per analysis, and have so far never been applied at <1 MeV.
Given these difficulties, this paper focuses only on the energy reconstruction scales which can be formulated purely analytically with relative ease: again, S1-only (Equation (2)), S2-only (Equation (3)), combined (Equation (1)), and the so-called optimized scale E (Equation (5)). To broaden applicability to more detectors, we also consider variants. Figure 2a shows S1-only in red and S2-only in cyan. The dashed red line illustrates how the S1 scale is poorer (the effect propagates into combined energy) when one does not account for the so-called “2-phe effect,” mentioned earlier [16]. Accounting for this via dividing it out improves the resolution, as the additional phe do not provide any new information on the original number of photons produced N p h , even though they may be useful in lowering threshold and increasing the sensitivity to lower-mass DM [74]. The solid red NEST line demonstrates the improvement achieved in doing this, plus attempting to reconstruct the integer numbers of photons hitting the photomultiplier tubes (PMTs), instead of only reporting S1 pulse areas. This technique is known as photon counting or spike counting [62] and is easy/feasible only at low E. More importantly than the slight improvement in energy resolution, at only the lowest energies (<10 keV), this reduces the leakage of background ER events into the WIMP (NR) region in S2 vs. S1 [18]. All points plotted are defined as raw σ / μ , but comparable results can be achieved with Gaussian/skew-fit centroids or medians.
Cyan lines represent S2, which, as seen before, can be better than S1 or even combined-E scales, but only at O(1) keV. It is at least comparable, which is important given the historical use of only S1 for E even in 2-phase TPCs with both channels, and continued usage for gas-less regions like the skin vetos of LZ and XENONnT. For S2, it is critical to understand the limitations, especially in low-mass-DM experiments like LBECA, where it is the only channel used. It can suffer from poor drift e lifetime (impurities), incomplete extraction at a liquid-gas interface due to fields being too low, or both. The former effect (same as latter) is shown by the dash vs. solid cyan. Even when lifetime and extraction are known, along with single- e pulse size, low values lead to high S2 area variation, although the effect is muted above 50 keV. The 41.55 keV “hiccups” are 83 m Kr, a combination of 2 decays, at 9.4 and 32.1 keV [75]. An inverse square root is not a good fit to the S2 or S1 alone and not included; it is due to incomplete accounting of quanta, also to linear noise flattening the curves. Such noise impacts higher Es more and is defined in detail in Section 4.3 of [36] and Section III.A of [58]. As seen in the ∼straight lines in log–log, a power law (often plus constant for noise) is reasonable for combined E (blue) but below ∼5 keV even E 1 2 breaks down, unless the power is free, preventing extrapolation from 10–100+ keV down to where behavior may even be non-analytic, and E resolution is ill-defined.
The NEST combined scale is in solid blue in Figure 2a compared to LUX data from its first science run as black circles. LUX used the same combined scale, which again is clearly advantageous compared to single-channel methods, with g 1 = 0.117 ± 0.003 and g 2 = 12.1 ± 0.9 [18,76]. The exception in the plot is the first point (2.8 keV) which should be compared to the optimized NEST in gold. The dashed and dotted blue lines are examples of further resolution improvements. First, by removing linear noise, in MC, as doing so is certainly not as easy in data (noise proportional to the S1 and S2 areas representing, e.g., imperfect position corrections). This is modeled as only 1.4% for LUX. It is typically O(1%) [36,58]. Second, respectively, by simulating a uniform electric field, when the real field varied with position, though not significantly in LUX’s first WIMP search run (180 V/cm average) and the (much larger) variation was taken into account in the second [77]. The last few highest-energy points in data (black) do not overlap with MC due to not fully accounting for PMT saturation (S2 clipping) above 500 keV.
The advantages of the optimal scale (gold) disappear rapidly above 10 keV, comparing gold to blue. There is a benefit to this. It means that at sufficiently high energies the rotating/re-weighting of a peak in S1 and S2 to find the optimal resolution results in a derivation of g 1 and g 2 [49]. This abrogates the need for multiple peaks, arranged in S2 vs. S1 (means) in what is known as the Doke plot. Such a plot is a straight line due to the anti-correlation between N p h and N e for ER [78] shown to work across at least four orders of magnitude in energy, and different fields [36,62,79,80]. Alternatively, if studies of anti-correlation both within peaks and across peaks for a given analysis in a certain experiment are possible, then these two methods for deriving the S1 and S2 gains can serve as cross-checks, on top of NEST comparisons and known-spectrum reproduction such as that from tritium betas [76]. As explained in the caption of Figure 2, the S1 weight w 1 is decreasing toward 0 with decreasing Es while w 2 increases to compensate; with increasing Es w 1 increases and w 2 decreases, while both ws asymptote to 1.0, as expected.
In the second plot plane (b), we focus on the mean instead of the width (resolution) demonstrating explicitly with both data from Compton scattering in black [65] and our NEST MCs (despite significant uncertainties) that the thresholding effects raise the reconstructed energy significantly above the true value. This phenomenon becomes most prevalent in the sub-keV regime, however, where resolution becomes ill-defined due to individual photon and electron quanta becoming resolvable, generating a multiple-peak structure [27]. The peaks become not just skewed-Gaussian, but entirely non-Gaussian, or even non-analytic [81]. For this reason, Figure 2a stops at 2 keV on the x-axis. Figure 2b continues below that, focused on mean (i.e., ratio of reconstructed over known energy) not width however. We switch to neriX from LUX here, as LUX does not have a relevant plot published with which we can compare, and did not have direct, quasi-monoenergetic measurements below 1 keV. (Nevertheless, due to similar g 1 ’s and g 2 ’s in these and most experiments the results should be quite general.) Data uncertainties are driven in x (E axis) by finite resolution in the Ge detector used for independent energy determination, and in y by uncertainties in neriX’s g 1 and g 2 (0.105 ± 0.003 phe/photon, 16.06 1.0 + 0.9 phe/ e ). NEST uncertainties are large only at sub-keV, and are not statistical due to large simulations. Instead they are due to the uncertainty on how to define a central value, using a mean or median or attempted Gaussian fit, due to the multi-peak effect mentioned (photon and e discretization).
At low Es, the benefits of not just a combined but optimally-combined (re-weighted) scale are significant: not just a built-in erasure thanks to w 2 of the growing discrepancy between the reconstructed and real values of energy illustrated effectively in Figure 2b (see also neriX’s Figure 7 [65]) but a reduction in width that was 50% (relative) for 37 Ar in both PIXeY and LUX. Lastly, as illustrated in Figure 1d, the shape becomes more symmetric at individual energies, with the skew nearly disappearing. While this matters more for monoenergetic ER peak searches (for axion-like particles or ALPs, bosonic WIMPs, etc.) a benefit for a WIMP search, or for any analysis in fact, is a better determination of the g 1 and g 2 through tighter windowing around single-energy calibration lines in 2D, in S2 vs. S1, which can occur iteratively, reducing the errors on g 1 and g 2 (5–10% typical) that often drive systematic uncertainties on both yield analyses and final physics results, especially in terms of S1 and S2 thresholds [18,58,76]. The only disadvantage is loss of the field-independence a combined scale usually has, as the yields change with field. As most experiments run at only one electric field however, that is not a true drawback.

3.1.3. High Energy: The MeV Scale (Neutrinoless Double-Beta Decay)

Far from the hard thresholds, we turn our attention next to 0 ν β β decay. Searches for this require great resolution for good background discrimination, at Q β β = 2.458 MeV for 136 Xe specifically [82]. While resolution naturally improves with E due to the greater numbers of quanta produced, effects such as PMT saturation and different noise sources, including position-dependent effects, become more prominent. While machine learning can help a great deal as done on EXO-200 especially with detector-specific idiosyncrasies [70], the analytic optimum scale becomes degenerate with combined E above 0.1 MeV even already as illustrated earlier. Table 1 reviews the resolutions achieved in actual experiments: projections of future performance, e.g., for LZ [83], are not included, in order to showcase only what has been demonstrated, or extrapolated with σ / E 1 / E (+ optional constant).
In EXO, in its references cited above, a richer formulation was adopted: σ 2 = a + b E + c E 2 . It considers more detector noise sources. For a = c = 0 , it simplifies to σ 2 = b E or σ / E = b / E .
The reader must be cautioned not to conclude that one technology (XENON is two-phase, but others single) is better, as fiducial mass and total exposure time, position resolution, overall background rate in the region of interest and self-shielding, and enrichment in 136 Xe come into play. The XENON series of detectors have focused primarily on DM not 0 ν β β and so were not enriched. Their intrinsically better resolutions are due not necessarily to the addition of a gas stage (converting Q into S2) but the use of PMTs with single-photon resolution, while EXO used silicon photo-multipliers (SiPMs) with poorer single-phe resolution (not needed at MeV energies) required for their lower radioactivity that is superior to even the custom PMTs for LZ/LUX and XENON [93,102,103,104,105,106]. Lastly, we do not explore GXe, for which there are many data points: NEXT has achieved better resolution than reported here, 0.1–0.3% (0.30–0.74 FWHM) due to lower total-quanta Fano and lower recombination fluctuations [107,108] both accounted for in NEST [48]. (The question of high mass vs. superior resolution is beyond our scope.)
What we can do is perform detailed MC scans to predict the best potential LXe resolution, for 2458 keV, but differing conditions; real experiments measure it at a nearby E, e.g., 2615 keV from 208 Tl. Validations are not overlaid, but we point to successes in predicting resolution for XENON1T [41,42,58] and postdicting LUX. To narrow the enormous parameter space, infinite e lifetime and 100% extraction efficiency (or, all-LXe detector like n/EXO) are assumed, with 0% noise in Q readout from the grids, but varying S1 noise level and wide E-field range for completeness. Second, an assumption is made of fixed medium g 1 = 0.1 , a conservative baseline based on what is possible now, while NEST systematic uncertainty will be shown, stemming mainly from different assumptions for the Fano factor.
Figure 3a is resolution dependent on g 1 , from a pessimistic scenario of 1%, all the way up to 100%. Higher E-field is only better at low g 1 , due to NEST’s strictly empirical Fano factor F q increasing with field. It is unphysical, but needed to match data claimed to be de-noised or low in noise [109]. This is important, given the rush to achieve higher field for better resolution [110] similar to the rush in the DM field, for lower leakage of ER backgrounds into the NR regime [53,56,111]. While L y and Q y are changing with E-field thus changing combined resolution, higher g 1 is naturally better, at least for non-zero field and combined E, due to more photons being collected. XENON1T, with its g 1 0.13 and field 120 V/cm, appears to have achieved close to the best possible for those values [41] at 0.8% (Table 1), also best overall. NEST’s theory prediction of 0.7% as best possible for XENON’s gs and field rises slightly to match at 0.8 when applying XENON’s e lifetime and e extraction efficiency [58].
In Figure 3b is E resolution’s dependence on Fano factor, from a theoretical value [112] (sub-Poissonian, ≪ 1) up to the largest experimental one, of Conti et al. [51]. This governs standard deviation: F q N q . While the best-fit (world data) NEST value, for 2.5 MeV and 500 V/cm, is 14 by default, we treat the Fano factor as free in Figure 3b, extending down to 0.2 due to NEST possibly absorbing detector-specific noises by mistake into the Fano value (even if this is not likely due to matching data across decades [41,109]). All the various EXO-200 results can be explained, as being between ∼2 and 5% noise levels in the detection of scintillation. The dotted cyan line holding steady at 4.4–4.5% explains precisely the seminal result with Q-only resolution of 4.5% in Table 1. It is not affected much by Fano factor, since when one considers only a single channel the recombination fluctuations, which move quanta between the scintillation and ionization signals, dominate [29,36,53]. It is very similar at different fields, since in the minimally ionizing regime (as ER energy approaches and exceeds 1 MeV) Q y and L y asymptote to constants [24,32,113]. The dashed line is too high to explain EXO’s S1-only values, but S1 resolution improves with more light at lower E-field (higher E-field increases charge, at expense of light).
Regardless of whether it is achieved through ramping up g 1 (not unrealistic for the future given 100% quantum efficiency QE devices [114] and high-quality reflectors [115]) or F q dropping to zero (it is not tuneable, at least not without doping of Xe with other materials; only feasible if the intrinsic value is already below Poisson, i.e., 1) the best possible value for resolution appears to be 0.4%, a “basement” created by binomial fluctuations in excitation and ionization, combined with non-binomial recombination fluctuations [52,79] if there is no noise (versus non-zero like 2% example in pane b). Given realistic detector conditions, a more reasonable estimate of the minimum possible here is 0.6% (comparable to gas).
Even if the total number of quanta is higher than assumed here, due to W being lower, as recently measured by EXO-200, 11.5 ± 0.5 eV [110] as opposed to 13.7 ± 0.2 eV (Dahl [36]) or 13.4 ± 0.4 eV (Goetzke, neriX [65]) or 13.8 ± 0.9 eV (Doke [78]), then this basement is unlikely to change significantly, as even F q = 0 was explored above. This discrepancy, observed in the light not charge channel and thus unlikely to be due to charge amp calibration differences, may be due to SiPMs being more sensitive (relative to PMTs) to wavelengths other than VUV, such as infrared (IR scintillation has been observed in LAr [116]). While at 2nd order the fluctuation models in NEST would have to be revised, to 1st order everything discussed here would remain the same, but with g 1 and g 2 estimates decreasing by ∼15%.

3.1.4. Energy Reconstruction and Efficiencies for a Continuous Spectrum

In searching for either 0 ν β β decay or the dark matter, a continuous-spectrum background can obscure any potential signal of beta decay or dark matter respectively, in addition to peaks in the background, or calibration peaks [90,117,118,119,120]. In our final ER analysis, we return to optimal combined E, but consider a non-monoenergetic spectrum. A new challenge appears, as cross-contamination between bins in a histogram can make it difficult to separate the upward fluctuations of lower Es from simultaneous downward fluctuations from the higher bins.
This difficulty is exacerbated by the fact that energy resolution is not fixed, so this is not a flat or linear effect with which it is easy to deal analytically. The resolution of course degrades as energy goes to zero. As a result of the light and charge yields depending on energy, an additional problem is the fact a spectrum flat in (combined) energy is not flat in the S1 nor the S2, and not all background spectra are going to be flat. That being said, this is approximately true at low energies for DM searches in LXe TPCs, after the contributions from all background radioisotopes are summed together, from Compton plateaus, neutrinos, and/or beta spectra, as in [24,42,53,58].
A naïve optimization attempt for a uniform spectrum that allows both w 1 , w 2 to vary distorts it more than normal. Better results are obtained fixing w 1 , unlike before. LUX is the example again: it is NEST’s default. A generic flat ER background is simulated from 0–20 keV in real energy (it should not be taken to represent the true backgrounds found within [49,118]). An excellent analytic fit for the detection efficiency vs. E for a continuous spectrum is a modified Gompertz function suggested by a LUX collaborator: 10 ( 2 m 1 e m 2 E m 3 m 4 e m 5 E m 6 ) / 100 % , which addresses both low-energy threshold and high-energy cut-off. (Typical values: m 1 and m 4 are O ( 10 ) while m 2 , m 3 , m 6 O ( 1 ) and m 5 O ( 10 4 ) .)
Figure 4a shows how the optimal scale, in gold again, is closer to the correct energies known from NEST MC in red, relative to traditional combined energy in dark blue again. 3 H (tritium) betas are not flat in energy but their LUX trigger efficiency should be similar enough to a flat spectrum, so it is included in black to verify NEST’s reasonableness [76]. A 3 H beta spectrum terminates ( Q β ) at an 18.6 keV endpoint, but finite resolution causes the fluctuations around that energy. In gold, the w 1 is held constant at 1.0, but w 2 = 1.025 e E 0.35 , basically adjusting for the growing deviation between reconstructed and real energies as showcased in Figure 2b using an S-shaped curve asymptoting close to 1.0 (without a shrinking w 1 , this weight w 2 has the opposite trend compared to Figure 2a). E in keV can stem from either the traditional combined scale, or MC truth, which in an actual experiment can be validated with a series of monoenergetic calibration peaks. The χ 2 /DOF = 2.65 for blue compared directly bin by bin with no fit to red at 0.5–17.5 keV, versus 1.68 for gold. Bin widths are 0.1 keV. The 50% fall-off point at high Es (perfect step function in true E in red) shifts from 19.5 to 20 keV, and is thus more accurate in gold compared to blue, forcing the endpoint smearing to be symmetric.
Figure 4b reiterates once more how distorted S1/S2-only E scales can be, in red/cyan. While Figure 1 did show S2-only can be best for low-E peaks, this is not the case for a continuum. Both S1/S2-only are non-uniform, despite the underlying spectrum being flat, and accounting for non-linearities in the underlying S1 and S2 yields, fitting quadratic not linear functions vs. (true) E. The flat top should be 0.005 as in the truth spectrum, due to normalization: bin width over range = (0.1 keV)/(20–0 keV) = 0.005. S1 is pulse area not spike, but in units of phd [16,19,62]. Despite this, there are unnatural peaks at both low and high E, caused by threshold and the maximum E simulated (20 keV), respectively.

3.2. Liquid Xenon Nuclear Recoil (Dark Matter Signal, and Boron-8 Background)

Pivoting toward nuclear recoil, the first hurdle is that for this type of recoil the total number of quanta per unit energy is not fixed, unlike what was shown for ER (first by Doke et al. at 1 MeV [78], and confirmed for energies of greater interest to DM experiments by Dahl [36]). This would seem to imply there is no anti-correlation between photons and electrons for NR and thus no benefit to using a combined energy scale for them. However, this does not appear to be the case, as the sum of quanta in actual data is well-fit by a power law, when combining all world data ever collected. This power law simply replaces the flat line (or general linear function but with no y-offset, if not dividing by energy: twice the energy means twice the N q ) that works so well for ER, given a fixed work function W q averaged over both flavors of quantum. This fit is related simply to the L ( E ) from Equation (1).
The mixing of units is possible, and depending upon whether one uses an S1-only, S2-only, or combined-energy scale, for NR the unit of keV e e can mean the beta, Compton, or photoabsorption event equivalent energy at which NR produces the same amount of S1, amount of S2, or the sum. In none of these three cases however is the conversion a simple constant or linear function, and can differ wildly, from keV e e being 2–10× smaller than keV n r , depending also on energy [15]. The reason it is smaller is it takes less energy for ER to produce the same number of quanta compared to NR for the same energy deposit ( L < 1 ). For the combined-energy scale, it is at least field-independent, as L should not depend on field, only the recoil energy, and the E resolution may be best via combination of information from both S1 and S2 again. (For additional clarity: some authors refer to L as f n [35]).
Figure 5 has all data available on N p h + N e , from which we extract L. The plots suggest combined E may still be beneficial even for NR, due to anti-correlation. The evidence is indirect, but strong: >300 data points from >20 experiments across nearly 2 decades were combined, respecting the systematics of each (typically driven by how well g 1 and g 2 were known). Remarkably, within uncertainty at least at the 2-sigma level the vast majority of the the hundreds of data points lie along the same straight line in log-log space. Publications reporting continuous lines stemming from, e.g., a modified NEST version or their own custom MCs are not ignored, but a few sample points at discrete energies are plotted. Figure 5’s plot style is similar to that pioneered by Sorensen and Dahl in [35] as well as in later works.
Uncovering direct evidence of anti-correlation in NR is challenging: monoenergetic neutron (n) sources exist, but internal monoenergetic NR sources do not. The common sources used such as AmBe and 252 Cf produce neutrons at energies O(1–10) MeV which lead to Xe recoils O(1–100) keV for calibrating DM detectors. While neutrons can be background [136], they are sub-dominant compared to ER [137,138] and appear more commonly as the stand-in for DM used to calibrate WIMPs, being neutral particles that primarily scatter elastically, as DM should do [6,139]. The closest one can get to separable recoil energies comes from determination of neutron angle and double scattering as done in LUX using a D-D neutron generator, but even in this most optimum situation the direct testing of anti-correlation was not possible: Q y , L y were reported at energies that did not match, and the former data included x-axis (E) error bars driven by uncertainty in angle, while the energy error for (single-scatter) L y data stemmed in turn from uncertainty from the Q y used to establish an in situ S2-only E scale [27,140].
As this is not a paper presenting any novel models (in NEST for instance), we do not focus on breakdown of the total quanta into N p h or L y and N e or Q y , which numerous papers already discuss at great length [141]. We also pass over the Migdal Effect, which could increase the light and/or charge at keV scales due to additional ER from initial NR; there is no evidence of its existence at present, but it is predicted to describe the behavior of electrons “left over” after a nucleus recoils [142]. Additional phenomena like it are secondary when combining all individual channels. Returning our attention to Figure 5a–c, the empirical total number of quanta is described by the following power law (black line):
N q = α E β , where α = 11.43 ± 0.13 and β = 1.068 ± 0.003 ; N q / E = α E β 1 11 q u a n t a k e V
Not only can summed data of [27,30,36,38,68,121,122,125,126,127,128,129,131,132,133,134,135] be described simply with a power fit but with an exponent near 1, implying a nearly fixed number of quanta/keV, ∼11.5 ( c f . 73 for ER, coming from 1 / W ), i.e., fixed L of ∼0.157. The conversion into L, re-arranging Equation (1), is:
L ( E ) = N q E W q = α E β 1 W q = ( 0.1566 ± 0.0018 ) E 0.068 ± 0.003 0.1707 + 0.0012 E
W q = 13.7 × 10 3 keV is assumed here with no uncertainty as just an example, while the last term is the Taylor expansion to first order at 10 keV. In Figure 5d,e, the fit to N q from data is compared to several models, starting with the traditional Lindhard approach [139,143]:
L ( ϵ ) = k g ( ϵ ) 1 + k g ( ϵ ) , k = 0.133 Z 2 / 3 A 1 / 2 0.166 , g ( ϵ ) = 3 ϵ 0.15 + 0.7 ϵ 0.6 + ϵ , ϵ = 11.5 E Z 7 / 3 0.00105 E
where Z = 54, A = 131.293 (average) for xenon. ϵ is called “reduced energy.” It allows dimensionless L comparison across different elements. A Taylor expansion for Equation (8) at 10 keV is L ( E ) = 0.1790 + 0.0028 E . At this E, the value of L for the expansion of Equation (7) is close, <5% lower than the one for Lindhard (8). Equation (7)’s linear approximation is lower for both of its terms, but this can be explained by bi-excitonic and/or Penning quenching, which increases with higher d E / d x , which occurs with increasing Es for keV NR. Colliding pairs of excitons may lead to de-excitation, and thus less S1 [131]. Some fraction of excitation may also be converted into ionization, adding to Q. Using the values in [30] or [133], it is even possible to show that NEST, similar to the data fit, follows Lindhard closely above O(1 keV) as long as additional quenching is added, for photons (see NR analysis note [15]).
This is remarkable given that it was not expected that Lindhard would work even that high in energy [28,131,132]. Yet data, once summed, exhibit no significant deviation from the Lindhard model, down to sub-keV even. At higher energy, the work of Hitachi [45,131], who incorporates quenching, may be more appropriate; however, it can be approximated using Lindhard but with k = 0.11 (blue). Figure 5d also includes the fit to LUX D-D n gun data alone (green) which agrees with standard Lindhard at the 1 σ level between 0.7–74 keV, given k = 0.174 ± 0.006 , after accounting for extra quenching, separately [27,62]. Sorensen 2015 in yellow in Figure 5e assumes standard-k Lindhard at high Es, and an atomic-physics motivated roll-off below 1 keV, with a free parameter q (in same units as ϵ ) we chose to best match all contemporary data, 1.1 × 10 5 or 10.5 eV. Only the min (blue) and max (green) k (which is uncertain and can range from 0.1–0.2 according to [28,35,134]) easiest to justify are depicted (Figure 5d). k = 0.166 would be between, as would k = 0.14 from Lenardo et al., best fit to data as of 2014 [144].
Any NEST version ≥2.0.1 has a power fit of 11 E 1.1 (red, Figure 5d) matching Equation (6) with rounding, but more importantly different because of considering not just raw yields but l o g 10 ( S 2 c / S 1 c ) band means, and giving greater weight to the lowest-E data, of greatest importance to a DM search [139] (previously 12.6 E 1.05 , before all statistical and systematic uncertainties were properly considered). The dashed purple line of Figure 5d is not just the power law but the full NEST that also since v2.0.1 to today includes sigmoidal corrections, separate in both L y and Q y , to allow for modeling of NR violating strict macroscopic anti-correlation. These cause the N p h and N e to realistically drop below the power law, conservatively accounting for non-Lindhard-like behavior below a few keV, and better matching data in this regime such as from the D-D calibration of LUX’s second science run [122]. Nevertheless, all models agree very well at low energies, all of them extrapolating at 200 eV to 1–2 quanta (see Figure 5f). Below 0.2 keV, NEST conservatively assumes 0 quanta, justifiable from first principles [15,28,48,132].
For greater readability several models have been omitted from Figure 5d,e, which do not include the work of Sarkis, Aguilar-Arevalo, and D’Olivo [28] nor of Wang and Mei [141]. This is not to say their approaches are not valuable, but the former is markedly similar to Sorensen [132] and to the complete NEST equation including a sub-keV roll-off despite starting with different formulae, while the latter is fit to the LUX data, and thus practically redundant with the dashed green. In Figure 5f we zoom in on energies <5 keV only, of greatest interest not only for lower-mass WIMPs, but any rest mass-energy WIMP due to the falling-exponential nature of NR from WIMPs, in the Standard Halo Model [6]. The cut-off in quanta may not be as sharp as expected due to the Migdal Effect adding more light at least [145]. Below 3 keV 8 B solar neutrino CE ν NS is of great significance as well, interesting in its own right for the first detection of the recently measured coherent scattering [146,147] but from solar neutrinos, and as a background to next-generation LXe-based WIMP experiments [1,148].
In following the ER section, the next step should be a discussion of the energy resolution as a function of energy. This has never been published for the combined scale with NR, however, to the best of our knowledge, except for plotting of the S1- and S2-only scales only once each as far as we know, by Plante [31,149] (but only at zero field, in a dissertation) and Verbus [27,140], respectively. In both situations these were only quasi-monoenergetic reconstructions, tagging neutron scatter angle with a Ge detector in the former case, as typical for all L e f f measurements, and i n s i t u in the same Xe volume (LUX) in the latter. For NEST comparisons to both of these, see Figure 3 bottom in the LZ simulation paper [150]. We also point to potential examples of threshold bias “lifting” Es above correct values (or, Eddington bias, for continuous spectra), as manifesting in light yields [112,151,152] seen much earlier for ER in Figure 2b but it is handled in later works [140,153] and thus not shown explicitly pre-correction.
Lacking truly monoenergetic peaks, continuous spectra present an opportunity still for contrasting the S1, S2, combined, and optimized-E scales. Those from all known n sources are highly dependent on geometry, however; thus NEST is insufficient: a full-fledged Geant4 MC [154,155] would be required to model detectors. Instead, an example of a 50 GeV/ c 2 mass WIMP will be shown with an unrealistically large cross-section of interaction (1 pb, and 1 kg-day exposure). While artificial, this illustrative example is valid given underlying assumptions for not just total quanta but individual photons and electrons, and resolution in both channels, verified by NEST comparison with data elsewhere [32,34,144] and real experiments will be able to test the ideas presented in future NR calibrations, in XENONnT and LZ.
Figure 6 is a repeat of Figure 4, but is for NR. The WIMP spectrum is more relevant than a uniform-E spectrum would be, as even for a massive (multi-TeV mass-scale) WIMP it is a poor approximation to what is inherently an exponential spectrum, falling as energy increases. The drop off on the left is of course caused as before by a combination of separate threshold effects that remove the lowest-energy S1s and S2s. The optimal scale shows improvement again over combined, but by itself combined E is not dissimilar from S1- or S2-only for NR, because the lower-quantum/area signals are dominated by detector specifics such as (binomial or Poisson) light collection efficiency. S1 only is most common, used in every experiment starting with the seminal XENON10 result [29] due not to a better energy reconstruction, but signal (NR) versus background (ER) discrimination [36,53]. S2 only may be as good for discrimination if not better however, according to the work of Arisaka, Ghag, Beltrame et al. [156].

3.3. Liquid Xenon Summaries

The key points of the LXe (ER) section (with detector-specific caveats) are:
  • A combined scale reconstructs monoenergetic ER peaks best for DM/ ν projects, but below 3 keV at least this is not true according to an 37 Ar study with S2-only best (outperforming S1 as well) if e lifetime is high. A combination can be established with two numbers, S1 and S2 gains, leading to a 1D histogram (XENON/LUX style) or equivalently a 2D rotation angle (Conti/EXO method).
  • An optimal weighting of S1 and S2 can result in better resolution than simple combined energy, down to O ( 1 ) keV even, and mitigation of threshold bias and skew. Higher, the best resolution occurs when the weights applied to the S1 and S2 are 1 / g 1 and 1 / g 2 , but machine learning is likely to outperform analytic methods, if more parameters (beyond S1, S2) are considered.
  • For neutrinoless double-beta decay, O(1%) resolution has been achieved in the relevant energy range by a multitude of different experiments and technologies, while the best feasible may be 0.4–0.6%, in liquid, which may be limited by a Fano factor (often confused with recombination fluctuations) that is higher than in gas. No one experiment has yet reached its full potential.
  • For a continuous ER spectrum, the combined scale is a clear winner over S1-only and S2-only alike, at least for a uniform energy distribution (uniform in neither S1 nor S2, as L y and Q y are functions of energy, not flat). Optimization with re-weighting is still possible, just in a different manner than done for monoenergetic peaks, because of cross-contamination between bins.
Next we summarize NR; there is good agreement on total yield from different experimentalists.
  • While impossible to obtain from truly monoenergetic lines, a summation of separate N p h and N e data sets results in strong evidence of NR anti-correlation akin to ER’s and no statistically significant difference from Lindhard even sub-keV, at least given additional high-E quenching.
  • Despite the point above, the advantages of a combined scale are not significant compared to the S1-only default (but S2 comparable) as so much E is lost to heat (>80%) decreasing pulse areas.
  • An optimized combination scale, which corrects for order-of-magnitude discrepancies in efficiency below 1 keV, is still best, but likely requires fine-tuning by energy spectrum. It is also likely to be highly detector-dependent and only important after a WIMP discovery is made, to fit the mass and cross-section the most precisely. A uniform spectrum is a bad approximation in any case.

3.4. Liquid Argon Electron Recoil

3.4.1. Low Energy: keV-scale (Dark Matter Backgrounds/Calibrations) Monoenergetic Peaks

For ER in LAr, the best example of a low-energy calibration line is the 83 m Kr peak, at 41.5 keV, commonly used to calibrate both LXe and LAr experiments, but in this latter case there exists no evidence of the yields depending on the separation time between the individual 32.1 and 9.4 keV peaks [157], unlike in LXe [75], so the MC comparison is easier. The 2.82 keV electron captured from 37 Ar has also been studied in LAr but most commonly at zero electric field in single-phase (liquid) detectors, making it a less ideal choice for complete NEST comparisons to S1, S2, and combined-E histograms [158]. For a WIMP search, ER is again the main background, due to 39 Ar in DarkSide-50 (DS-50) at Gran Sasso [159], DEAP-3600 (and formerly CLEAN precursors) at SNOLab [160,161], and ArDM (at Canfranc). Underground Ar depleted in this isotope reduces the background, but it remains dominant [162]. In neutrino experiments, ER is the signal, via neutral-current, charged-current, and elastic-scattering interactions. In this section, we begin by focusing on dark matter at the keV scale, later moving on to cover the GeV scale more relevant for accelerator neutrino experiments like DUNE [163], with the intermediate scale at MeV also important for supernova or solar neutrinos [164,165].
Predictions of NEST’s LAr ER model in comparison to experimental data are shown in Figure 7. The source of data here is DarkSide (DS), specifically several PhD theses of its students [21,22,23]. For this experiment, g 1 = 0.18 ± 0.01 phe/photon [21], higher than within LXe detectors likely because of conversion of VUV photons into visible light using wavelength shifter followed by detection in high-QE visible-light SiPMs/MPPCs/APDs (Silicon Photo-Multipliers or Multi-Pixel Photon Counters or Avalanche Photo-Diodes). Another source gives this as g 1 = 0.1856 ± 0 . 0007 s t a t ± 0 . 0008 s y s t [23]. On the S2 side, g 2 = 27 ± 9 phe/electron from [21] or 29.2 ± 0 . 5 s t a t ± 1 . 6 s y s t according to [23]. Note that the gain factors g 1 and g 2 are called ϵ 1 and ϵ 2 by DS; others call them α 1 and α 2 .
To most closely center NEST with respect to DS data in Figure 7, we set g 1 = 0.181 and g 2 = 23.8 , both well within the above uncertainties. Only one example electric field was studied, of 200 V/cm, comparable to the electric fields studied earlier for LXe. The work function or W q was assumed to be 19.3 eV, a value justified later when discussing reconstruction for neutrino detectors. Reconstructed energy is again keV e e as opposed to keV (without the subscript) for known individual energies.
Unlike in LXe, the S1-only energy scale does not necessarily perform the poorest. Our particular 83 m Kr example has an energy resolution σ / μ of 6.5%, in Figure 7a. The S1-based scale is more reliable in LAr due to its greater linearity, wherein the light yield for different betas and gamma rays is quite flat in energy, starting at 40–50 photons/keV and falling as the electric field rises and more energy goes into charge production [78,157,169,170,171,172,173,174]. Next, in Figure 7b, the S2-only scale is plotted, leading to a resolution of 25%. Reproducing this large width was done artificially by setting the linear noise in the S2 channel to 25.0% (only 2.9% for S1 to match that width, an effectively negligible value). Compare this to 6.0% (S2, so high due to e trains/tails/bursts [57]) and 1.4% (S1) assumed by default for LUX Run03 within NEST. We interpret the cause of the large value for S2 in LAr as stemming from a lack of full 3D corrections in the initial DS analysis. There is also a clear offset in skew compared to the MC which may come from DS-specific effects difficult to fully capture in a custom MC like NEST that does not account for all detector idiosyncrasies. No (statistical) errors are depicted as they are negligible from this high-statistics calibration.
Figure 7c shows a combined resolution of 7.5%, not improving on the S1-only resolution, but still a marked improvement over S2-only, suggestive of anti-correlation of charge and light in LAr (more robustly established later in this section). The agreement is even worse with MC here, however, than in the S2 plot, but this can be explained by the peak being from a different analysis from (a) and (b), with the Kr calibration sitting on top of a large background, from 39 Ar inside natural Ar, which we did not model (this is the only example of a DS combined-energy peak we were able to locate). In the original source the peak was not centered on 41.5 keV e e , likely due to a systematic offset in g 1 and/or g 2 (see contradictory values above) but we had no difficulty in NEST with this. For ease of comparison for at least the width, 2.5 keV e e was added to data, to force alignment to a 41.5 keV(ee) mean [23].
Figure 7d is the combined-E resolution vs. E. NEST is in blue. The data have full position corrections from high-statistics 83 m Kr calibrations [21,22,23] as in LXe. They are most crucial for S2, in XY (or radius and angle) as Z is already handled by electron lifetime. NEST points for comparison are at semi-log steps in E = 2–5000 keV. While retaining the 3% S1 noise term from earlier, they have had the 25% S2 noise from (b,c) removed, so they can be effectively treated as close to the MC-predicted min possible, at least for the given (DS-50) combination of g 1 , g 2 , and E-field. The combined-E resolution drops from the 7.5% in (c) to below 5% in this case at 41.5 keV in (d). The empirical S2 noise term was thus likely accounting for imperfect correction for the (2D) position-dependent S2 light collection.
There is no equivalent of Figure 2b for LAr, as no example of Eddington-like bias could be found. An opposite effect (lower instead of higher reconstructed E) is recorded in Figure 3.11 of [23]. However, this can easily be interpreted as E “loss” into charge when using only S1, which while more linear in LAr compared to LXe, is still not a fixed flat L y at all energies, not even at null electric field [158,175].

3.4.2. High Energies: The MeV and GeV Scales (Neutrino Physics)

In moving from the keV scale of DM experiments to the GeV scale of the accelerator neutrino experiments, we study the MeV scale as a boundary case. A 1 MeV beta was chosen as an example of an ER interaction energy just beyond what is considered relevant for a DM search, but on the other hand, at the extremely low-energy end for neutrino physics, potentially just barely above threshold in an experiment like DUNE [176]. This is of the same order of magnitude but just slightly above the 39 Ar beta spectrum endpoint (565 keV), and is also near the same energies (976 keV and 1.05 MeV internal-conversion electron and gamma ray, respectively, from 207 Bi) studied by Doke et al. in their seminal 1989–2002 papers [78,169]. Our own re-analysis shows that if one sums L y and Q y vs. electric field, it is a constant number of quanta/keV within experimental uncertainties, and consistent with 1 / W q , given reasonable assumptions on g 1 and g 2 .
An energy of 1 MeV is also associated with a track length at the border of position resolution in an experiment like DUNE, <1 cm on average, creating “blips” instead of obvious tracks, straddling the point-like interactions observed in DM detectors vs. the track-like nature of most interactions in LAr TPC, or LArTPC for short, neutrino experiments. Its low d E / d x is also at the cusp of the minimally ionizing regime, making a 1 MeV electron a Minimally Ionizing Particle (MIP), like electrons from GeV-scale neutrino interactions prior to showering [177]. In neutrino detectors there is no g 2 however, as electron charge is directly measured, as on EXO, by wire planes instead of S2. They are one-phase liquid TPCs with unit gain for charge readout. Table 2 scans different levels of energy resolution associated with noise from the wire readout, showing the best (lowest) resolution for different values of g 1 . Combined-energy and even S1-only resolution appear in the table, for high g 1 paired with high wire noise.
Resolution in a DUNE-like detector can be halved already at g 1 = 0.02 , i.e., 2%, for 10% wire noise. Such noise, starting even at 1%, comprises Q-only resolution almost entirely. For 0% wire noise, the 0.46% resolution is driven by excitation and recombination, both contributing binomial fluctuations (unlike in LXe). F q drives combined-E results. Its theoretical value 0.1 was assumed, given no other data [168]. For S1 only, a g 1 -based binomial drives what is possible. 0% noise was assumed for S1.
Unfortunately, large LArTPC neutrino experiments like DUNE will achieve much lower values of g 1 [178], though g 1 = 2 % is already much lower than any Xe or Ar DM experiment has achieved. At higher levels of noise, still realistic for future experiments but energy-dependent, even lower g 1 suffices for making combined energy superior to Q-only. When reading this table from the top down, if the value starts changing this means that the minimum resolution being quoted is from the combination of scintillation and ionization, and no longer just the ionization. If reading across: when the values stop changing that means (at high g 1 ) an S1-only scale is best, as at higher levels of wire noise not only does the Q-only energy scale become unreliable, but the benefit in utilizing the anti-correlation of charge and light washes out for the combined scale, leaving the S1-only scale.
The small-scale LArTPC R&D detector, Liquid Argon In A Test beam (LArIAT), has investigated the claim that the combined-energy scale, making use of both ionization charge and scintillation light, is more precise [179,180]. While not targeting the removal of the wire noise, it does effectively cancel out the exciton-ion and recombination fluctuations, shown using a sample of Michel electrons (from muon decay) at a scale of tens of MeV. Here, the definition of combination is more appropriately set for neutrino interactions using differential energy loss along the particle track, updating our earlier equations, starting with (1) but with L = 1 assumed as for all ER: -4.6cm0cm
E = ( L y E + Q y E ) W q = ( d S d E E + d Q d E E ) W q d E d x = ( d S d E d E d x + d Q d E d E d x ) W q = ( d S d x + d Q d x ) W q ,
where the number of photons N p h and number of electrons N e are replaced for the first step by L y and Q y , specific yields per unit energy, each multiplied by energy.
Next, to align our terminology with what is more common in the neutrino field we rewrite L y as d S / d E and Q y as d Q / d E [181] (instead of N p h / E and N e / E , with S and Q standing respectively for scintillation and charge, the quantum values). S is used for the scintillation light instead of L to avoid confusion with Lindhard factor. The resultant formula above is still not what is most commonly used in the field. Instead, that is:
d E d x = d Q d x d E d Q = d Q d x Q y 1 ( E , E ) .
This is equivalent to the S2-only scale used in dual-phase TPCs from Equation (3) where E = N e / Q y ( E , E ) , except divided by d x and with g 2 = 1, given no need for extraction from liquid to gas, nor any photons created by electrons as a secondary process in gas (S2, i.e., electroluminescence). Although, the electron lifetime must still be high, ideally much larger than the full drift time across a TPC, and also well-measured, so that the Q can be corrected in the same way as S2. Q y (or N e / E ) is often parameterized with Birks’ Law [32,175,182] in terms of d E / d x instead of E:
Q y ( d E d x , E ) = A 1 / W i 1 + ( k B / E ) ( d E / d x ) = A Q 0 ( E ) / E 1 + ( k B / E ) ( d E / d x ) ,
where W i (sometimes called W e ) is not the same as the work function W q defined much earlier, but trivially related. Being defined as E / N i , not E / ( N e x + N i ) , the convention of ionization W is related to the overall or total work function by W i = ( 1 + N e x / N i ) W q . ( N e x / N i are excitons/ions).
For LAr, this means W i = ( 1 + 0.21 ) W q = 1.21 ∗ (19.5 eV) = 23.6 eV, approximately [78,183]. Note LAr’s W q has been labeled W p h m a x [78], as it is related to the maximum possible L y , when Q y = 0 , but this is not possible even at 0 V/cm (it does become possible as ionization density from interactions goes to and forces recombination in both LXe and LAr [78,184]). Drift electric field is E while k B is known as Birks’ constant, and A is the correction factor explained later. Q 0 is effectively the maximum possible charge, at infinite E , defined as E / W i or N i . While Birks is not the only possible parameterization (e.g., there is also the Thomas–Imel box model [185,186]) the focus of this work is on energy reconstruction not the various microphysics models. We thus take Birks to only be a representative example here.
Another approach, taking into account not just excitation vs. ionization, but e -ion recombination, begins the same as for LXe [35,36,144], and LAr experiments used for DM instead of neutrinos: -4.6cm0cm
E = N q W q = ( N p h + N e ) W q where N p h = N e x + r ( E , E ) N i and N e = [ 1 r ( E , E ) ] N i .
Here r refers to the recombination probability and depends not only on energy and electric field but also the particle or interaction type, N e x is the number of excited atoms initially produced, and N i the number of e -ion pairs. In this case, N p h + N e is also N e x + N i . Applying the same revision to Birks’ Law suggested in 2011 by Szydagis et al. for Xe [32] to Ar recasts it in terms of first principles:
r ( E , E ) = k ( E ) d E / d x 1 + k ( E ) d E / d x , N e = ( 1 r ) N i N e E = Q y = ( 1 r ) N i E = 1 r W i = 1 / W i 1 + k ( E ) d E / d x ,
with k ( E ) = k B / E only one possible parameterization of recombination’s E-field dependence, and in turn charge and light yields, with a more general negative power law possible [32,187]. Only the A from ICARUS [188] is lacking in terms of robust justification, but it is likely a correction needed only when the secondary particle production range cut in the Geant simulation is set too high to allow for delta-ray formation down to keV-scale energies. Delta rays are lower-energy, higher- d E / d x tracks with greater recombination, hence more light, at the expense of charge, explaining why A < 1 . Increased simulation time and memory usage associated with lowering the secondary particle production range cut often lead this cut to be set too high in Geant simulations to capture this effect.
In Figure 8a, the number of ionization electrons produced from a 1 MeV primary electron is plotted versus both the Geant4 secondary production range cut (“length scale factor”) as well as the associated energy threshold for delta rays. The ratio between the values of the two plateaus at the left and right extremes in Q is almost exactly equal to the ICARUS best-fit value of the renormalization constant A (0.800 ± 0.003 in Amoruso et al. 2003 [188]). The default secondary production range cut of 0.7 mm used in the LArSoft (Geant4) simulation allows for only ∼270+ keV delta rays to form [189].
Figure 8b (upper right) shows that the lower plateau in the large left plot (a) in its lower left corner is closer to correct. The zero-electric-field light yield for a 1 MeV beta, or other electron, is approximately 41 photons/keV [169] while the red line in (b) shows a reduction to ∼0.6 of that value by 500 V/cm, to 24.6 photons/keV. If the work function is 19.5 ± 1.0 eV, as reported also by Doke, this implies a total (S and Q summed) of 51 . 3 2.5 + 2.8 quanta/keV (an S value different than 41, potentially higher, only strengthens our following arguments by lowering Q). The charge yield is total minus light, leading us to 51.3 24.6 = 26 . 7 2.5 + 2.8 e /keV. The NEST (2012) value is thus very much within the error envelope of actual data for the lower level, but outside it for the higher one, which also never quite flattens (Figure 8a upper right). Including more relevant measurement uncertainties does not sufficiently explain this discrepancy. A similar conclusion can be reached by converting relative charge (green curve in Figure 8b) to absolute, pointing again toward the lower value of Q being the more correct one. Figure 8c demonstrates fully accounting for delta rays is also important for correctly predicting ionization-only E resolution for primary electrons at these energies (∼1 MeV).
The 2012–2013 version of the NEST LAr ER model was a combination of the Birks-Law and Box (Thomas–Imel) models of recombination, with LET (Linear Energy Transfer) < 25 (MeV·cm 2 )/g driven primarily by Birks, as given by Equation (13) (with the Thomas–Imel box model still called for accompanying delta rays). There was no need for renormalization as in Equation (11) (so that A = 1 ) due to using a significantly smaller secondary production range cut in Geant4, and the Birks’ constant’s electric field dependence was k ( E ) = 0.07 / E 0.85 ( c f . Amoruso’s k ( E ) = ( 0.0486 ± 0.0006 ) / E ). The different power on the electric field dependence, less than 1, on top of the different constant within the numerator is likely due to using Birks to model the recombination directly instead of R = 1 r or Q Q 0 . In addition, it was based on higher-LET dark matter detector data and extrapolated lower. This is also nearly identical to Equation (8) from Obodovskiy’s comprehensive report [187].
One point of confusion to address is the most common quantity used for data/MC comparison in the neutrino field, the recombination factor, R. It is actually an “escape” factor for electrons from ionized atoms: Q = ( 1 r ) N i R = 1 r = Q / N i = Q W i / E , where W i = 23.6 ± 0.3 eV [183]. See the NEST 2013 comparison to ICARUS data (from both muons and protons mixed) in Figure 9, where a good match is observed. This is a different NEST version from the dark matter experiment (DarkSide) comparisons earlier at lower energies (higher d E / d x ) because at time of writing the ER model for LAr in the latest NEST version has not been recast yet into a d E / d x basis for a robust comparison [192,193] assuming a typical LAr density of 1.4 g/cm 3 . Minor discrepancies are observed at low d E / d x , which will be addressed with planned improvements to the NEST LAr ER model in the near future.
The corrections discussed here are important not only for energy reconstruction considerations but also for background discrimination, such as for differentiating neutral pions, photons, and e + e pair production from single electrons which comprise the signal of interest for accelerator neutrino experiments. This particle identification can be carried out with the use of d E / d x by first measuring d Q / d x [194]. Potentially one can add in d S / d x for a low-enough energy threshold, if the g 1 is high enough, as discussed earlier. The exclusion of delta rays common in typical Geant4 simulations for LArTPC neutrino experiments affects not only the mean yields, which can still be simulated accurately with a 20% correction almost independently of electric field and LET, but also resolution: delta rays will degrade the energy resolution and require more complicated corrections if they are deactivated in Monte Carlo simulations (in Figure 8c). Incorrectly-modeled energy, and thus d E / d x , resolution can lead to potential biases between data and simulation when using reconstructed d E / d x for particle identification: electron/photon discrimination in LArTPC neutrino experiments for example.

3.5. Liquid Argon Nuclear Recoil (Dark Matter Signal, and CEvNS)

The final topic is low-energy (keV-scale) nuclear recoil or NR within LAr, which is important not only for dark matter in experiments such as DS [195] but also for CE ν NS on collaborations like COHERENT [196]. The sum of quanta in data is again fit well by a power law, combining all global data on total yields, related to L ( E ) from the beginning, Equation (1).
The fit in Figure 10 is quite similar to that from LXe earlier in Figure 5 in both the base and exponent. Here we plot total quanta/keV instead of just quanta for greater clarity: in terms of quanta the power would be 1.087 ( c f . 1.068–1.1 for xenon). Data are scarce for N q in Figure 10a, as most LAr data for DM traditionally were 0 V/cm (e.g., microCLEAN, DEAP) thus lacking N e to add to N p h . L e f f data exist from many sources, collected in [161,197,198,199] but these do not directly inform L, being just L y .
Lindhard works surprisingly well according to Figure 10b, staying within 2 σ for the power fit to data below 50 keV. Deviation below Lindhard at high E is easy to understand as bi-excitonic quenching again as per Hitachi, while (some) deviation at sub-keV is also understandable, as Lindhard’s approach should break down at <1 keV regardless. The total number of quanta per keV is remarkably flat from 1–300 keV, around 15 quanta/keV. Breaking the total down into light and charge, a similar behavior is observed as in LXe, with L y increasing in energy, while Q y decreases [175,200]. Confusion between L y and total yield has led to past claims Lindhard does not fit well [200,201]. Regardless of whether Lindhard fits well or does not for some energy regime, Figure 10a is indicative of a combined-E scale being worthwhile (in place of S1 only) as in LXe, as argued both by DS [23] and LArIAT [180].
The final plot, Figure 11, displays the breakdown into the S1 and S2 pulse areas for one example energy coming from the same quasi-monoenergetic technique cited earlier for table-top LXe yield measurements (for both ER and NR) relying upon coincidence between a noble-element detector and a second detector, typically Ge [31,65,175]. For NEST MC, the means of their values for the gains have been assumed: g 1 = 0.104 ± 0.006 PE/photon and g 2 = 3.1 ± 0.3 PE/ e . The drift electric field was 193 V/cm and sample energy 16.9 keV, selected due to being the lowest value for which the S1 and S2 histograms are displayed at an identical energy anywhere within the existing literature.
NEST seems to overestimate the L y , but a larger issue is at play: contradictory data exist for NR from over the past ∼two decades: some experiments showed the amount of scintillation staying flat, others decreasing, and several even increasing with decreasing recoil energy [161,197,198], physically possible if one adapts the logic from Bezrukov, Kahlhoefer, and Lindner from LXe on screening [133]. Those showing increase cannot be easily explained as caused by threshold bias, as several distinct sets of results agreed upon the increase [195,200]. Other hypotheses include different collection efficiencies, especially as wavelength shifters are generally used in LAr, and different ones [204], some of which may have efficiencies higher than 100% effectively due to creation of multiple visible photons per individual input photon in the extreme UV, though the data on the existence of this are also contradictory [205]. A related effect may be something in photo-sensors exposed to LAr analogous to the 2-PE effect seen in LXe. A compounding problem is the discrepancy for the zero-field L y for 57 Co (or 83 m Kr) used as in LXe to set L e f f . Historically, it is stated as near 40 photons/keV [169] but more recent work, with g 1 known by Doke plot, suggests closer to 50, nearer the max ( 1 / W q ) if Q y 0 , sensible for E 0 [166] (though as explained earlier, unrecombined e s remain). Systematic uncertainty in L y at ∼20 keV may be as high as 40 % ( L e f f = 0.35 , or 0.25) making the 20% shift (×0.8) needed in Figure 11a not unreasonable.
At time of writing, NEST’s compromise solution to the contradiction is to follow the predictions of not just Lindhard but all existing first-principles models, as well as the most recent data (ARIS) suggesting a flat-ish L y building into a mild increase with increasing NR energy, but at a higher level than the traditional ∼10 photons/keV (0.25 L e f f × 40), better matching the claims of high L y at low E [175]. (Earlier versions would switch between differing, mutually exclusive solutions).
Figure 11b suggests an S2-only scale may ironically be more reliable for (NR-based) DM searches with LAr. Contradictions are fewer between data and different models, including NEST, even at other energies, and multi-ms e lifetime may be easier to achieve through high-level purification [159,206]; however, a note of caution that this may be due to the paucity of non-zero-field data, for measuring Q y , at multiple E-fields. Columnar recombination, not currently simulated, which changes the yield depending on electric field orientation, is a further complication [200]. The combined-E scale essentially removes the effect of these and any other recombination fluctuations, which cause the variance in the original numbers of photons and electrons to be identical “at birth” prior to any fluctuations due to propagation and/or detection [36,51]. Such a scale will also remove the effect of delta rays (ER) on the ultimate energy resolution achievable, if driven by anti-correlated fluctuations (recombination).
S2 is generally easier to measure, however, than the S1 is: electrons drift upward in a TPC along nearly-straight lines (slight diffusion occurs) from the liquid to the wires or to the wires followed by gas, where many photons are produced per electron. Losses due to the impurities along the drift length can be quantified simply, with an exponential. On the other hand, scintillation photons are produced in all directions and are affected by not only attenuation (not necessarily exponential, but difficult to quantify analytically) but geometric collection efficiency driven by reflection and refraction, and QE. As energy decreases, Q y increases for both NR and ER, for both LAr and LXe, at least down to the keV level before turning around, while L y appears to decrease toward 0. For this reason, NEST models are created using the total yield first, then charge yield, and light reconstructed by subtraction in the code. (The same is true for LXe.)

3.6. Liquid Argon Summaries

In conclusion, the key points of the LAr ER section, coupled to reasonable/common detector parameter values including/especially g 1 and E-field E , are:
  • A combined S1 + S2 scale continues to reconstruct ER energies best for DM/neutrino experiments, due to anti-correlation between channels, but not if g 1 is very low (≪1%) or g 2 very high (e.g., 2-phase TPC). An additional challenge is created by sitting on top of a continuous background like the beta decay of 39 Ar for combined energies, but noise in Q can make S1 more favorable.
  • d E / d x is more important than just E at the GeV scales of greatest relevance to neutrino projects and it is most commonly reconstructed utilizing d Q / d x (ignoring d S / d x ).
  • A correction (∼0.8) must be inserted into the simulation of charge yields for use in the traditional Q-only scale, lowering the Q that is output, if the delta-ray production threshold is set above the e -ion thermalization radius O(1 m) in MC. Energy resolution may also be affected, not just mean yields, and high-energy, low- d E / d x (MIP) interactions are not immune to this problem due to secondary particle production, handled with, e.g., Geant4.
  • Due to differences in delta rays and other secondaries, an analytical fit may be impossible across all particle types, leading to different recombination probabilities even if you consider only the averages versus d E / d x or energy.
  • Either escape probability or recombination can be modeled as a function of the d E / d x (or the LET, which includes the effects of density).
Next, we summarize the key points of the LAr NR section. We note that because yields change slowly with increasing field especially for the dense tracks of NR that our S1 examples from two-phase TPCs (DS, ARIS, SCENE) should be relevant/applicable to 0 V/cm single-phase detectors as well.
  • While possible to measure for only approximately monoenergetic peaks, a summation of the few available N p h plus N e data sets results in evidence for NR anti-correlation (akin to ERs) and modest agreement with Lindhard. This is important for both DM and CE ν NS.
  • Due to uncertainty in the scintillation yield, an S2-only scale may be beneficial, but exploration of combined E may still be interesting in the future (as stated above). Non-zero-field measurements are not as plentiful for charge yields as zero-field light-only ones for NR in liquid argon.

4. Discussion and General Conclusions

We have reviewed mainly LXe and LAr, in 2-phase TPCs, and managed to extract insights spanning dark matter and neutrinos, proving once again the remarkable consistency obtained across numerous data sets, and the utility of NEST to probe at least the simple reconstruction methods reviewed. From an historical perspective, it is intriguing that the usage of noble elements in the DM field began with scintillation-only E measurements, with charge primarily used for position reconstruction, while for neutrinos the opposite occurred: ionization-only E scale, with initial scintillation used as a trigger for event activity of interest. Moving forward in both fields, it will be interesting to see how charge and light are combined together to improve E measurements further than what has already been achieved.
The new insights we have gleaned from our review and meta-analyses with our own simulations, based on the global, cross-experiment framework of NEST, first for liquid xenon, include:
  • The first comparison as far as we know of the same one monoenergetic ER peak ( 37 Ar calibration) across S1-only, S2-only, and two versions of combined energy (standard and optimized) with both real data and NEST, with skew-Gaussians adjusting for detection efficiency and other effects. Width for S1 only was shown to be ∼4x worse than the best possible.
  • The only full explanation published for an optimized (weighted) combined-E scale (not in a thesis or an internal report).
  • While the combined-E scale has already been established as superior to S1-only in past work, we explore also an S2-only scale and show it may outperform combined energy at the keV level, but only for monoenergetic peaks and high g 2 .
  • Demonstration that combined energies (even non-optimal) improve not just the widths and thus energy resolution, as already established in the community, but also reconstructed mean energies, and shape (i.e., symmetry or skewness).
  • Replication of measured upward bias in E reconstruction with NEST, suggesting it is due to both thresholds and physics.
  • A summary of energy resolutions from 0 ν β β experiments, with MCs suggesting where to make improvements.
  • Clear delineation of the difference between recombination fluctuations, which affect S1 vs. S2, and the Fano factor, that controls their total, as the literature is currently unclear on this, with one term often being used incorrectly for the other.
  • A complete comparison analogous to (1) above for the efficiency vs. reconstructed E, for both ER/NR, as reconstructed by S1, S2, and both (standard and optimum combination) compared together for a simple continuous spectrum (box/WIMP).
  • The most complete compilation to date of NR Q y + L y , showing also a Lindhard-like power law matches the total yield.
For liquid argon, items of interest presented here that were new, to the best of our knowledge, are:
  • The first comparisons of NEST performed for LAr, in plots for dark matter at low energies and neutrino physics for high Es (vs. d E / d x ) never presented before, demonstrating a new understanding of mean yields and widths, requiring G4.
  • An exhaustive simulated table relevant to neutrino physics that goes beyond existing data, and predicts a significant improvement in E reconstruction at an energy (1 MeV, low LET) still relevant to neutrinos, for sufficiently high g 1 .
  • A demonstration that anti-correlation was “hiding” in seminal work by Doke et al. with an explicit reanalysis of the original paper showing photons and electrons sum to a constant for a MIP in LAr as a function of E-field at fixed E.
  • A clarification of confusing/conflicting definitions of work function, recombination probability, and charge yield.
  • Quantitative proof confirming the hypothesis ICARUS’ data required a correction specifically for not having delta rays activated in simulation, plus the first evidence not just mean reconstruction of charge is affected but also the width.
  • A comprehensive compilation of all existing data and models for NR in terms of total yield not just light, beyond 0 V/cm.

Funding

The research of Levy and Szydagis at the University at Albany SUNY (State University of New York) was funded by the U.S. Department of Energy (DOE) under grant number DE-SC0015535. Mooney and his students, Alex Flesher and Justin Mueller, were funded through university start-up funds. Kozlova was funded through the Russian Science Foundation (contract number 18-12-00135) and Russian Foundation for Basic Research (projs. 20-02-00670a).

Acknowledgments

The authors wish to thank these members of the LZ and/or LUX collaborations who reviewed a draft of the Xe section informally and provided helpful comments: Henrique Araújo of Imperial College London, Andrew Stevens from Oxford University, and Chamkaur Ghag of University College London. We also thank Dan McKinsey and all of his students and postdocs who worked on PIXeY, with whom we have had very fruitful discussions over the years. Lastly, Szydagis thanks Jason Sokaris and Steve Cifarelli for early work on the optimized energy scale, as well as Dmitri Akimov of MEPhI, for allowing his advisee E. Kozlova to work on NEST, and on this paper.

Conflicts of Interest

The authors declare that the author list of this paper includes members of the LZ, LUX, nEXO, DUNE, MicroBooNE, SBN, CENNS-10, COHERENT, and RED collaborations.

References

  1. Akerib, D.; Akerlof, C.; Alsum, S.; Araújo, H.; Arthurs, M.; Bai, X.; Bailey, A.; Balajthy, J.; Balashov, S.; Bauer, D.; et al. Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment. Phys. Rev. D 2020, 101, 052002. [Google Scholar] [CrossRef] [Green Version]
  2. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; et al. First Dark Matter Search Results from the XENON1T Experiment. Phys. Rev. Lett. 2017, 119. [Google Scholar] [CrossRef] [Green Version]
  3. Cui, X.; Abdukerim, A.; Chen, W.; Chen, X.; Chen, Y.; Dong, B.; Fang, D.; Fu, C.; Giboni, K.; Giuliani, F.; et al. Dark Matter Results from 54-Ton-Day Exposure of PandaX-II Experiment. Phys. Rev. Lett. 2017, 119, 181302. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Li, C.Y.; Si, Z.G.; Zhou, Y.F. Constraints on dark matter interactions from the first results of DarkSide-50. Nucl. Phys. B 2019, 945, 114678. [Google Scholar] [CrossRef]
  5. Ajaj, R.; Amaudruz, P.A.; Araujo, G.; Baldwin, M.; Batygov, M.; Beltran, B.; Bina, C.; Bonatt, J.; Boulay, M.; Broerman, B.; et al. Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB. Phys. Rev. D 2019, 100, 022004. [Google Scholar] [CrossRef] [Green Version]
  6. McCabe, C. Astrophysical uncertainties of dark matter direct detection experiments. Phys. Rev. D 2010, 82, 023530. [Google Scholar] [CrossRef] [Green Version]
  7. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; et al. Search for bosonic super-WIMP interactions with the XENON100 experiment. Phys. Rev. D 2017, 96, 122002. [Google Scholar] [CrossRef] [Green Version]
  8. Abi, B.; Acciarri, R.; Acero, M.A.; Adamov, G.; Adams, D.; Adinolfi, M.; Ahmad, Z.; Ahmed, J.; Monsalve, A.T.; Alonso, S. Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume I: Introduction to DUNE. arXiv 2020, arXiv:2002.02967. [Google Scholar]
  9. Abratenko; Alrashed, P.; An, M.; Anthony, R.; Asaadi, J.; Ashkenazi, J.; Balasubramanian, A.S.; Baller, B.; Barnes, C.; Barr, G.; et al. A Convolutional Neural Network for Multiple Particle Identification in the MicroBooNE Liquid Argon Time Projection Chamber. arXiv 2020, arXiv:2010.08653. [Google Scholar]
  10. Anton, G.; Badhrees, I.; Barbeau, P.; Beck, D.; Belov, V.; Bhatta, T.; Breidenbach, M.; Brunner, T.; Cao, G.; Cen, W.; et al. Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset. Phys. Rev. Lett. 2019, 123, 161802. [Google Scholar] [CrossRef] [Green Version]
  11. Woodruff, K.; Baeza-Rubio, J.; Huerta, D.; Jones, B.; McDonald, A.; Norman, L.; Nygren, D.; Adams, C.; Álvarez, V.; Arazi, L.; et al. Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon. J. Instrum. 2020, 15, P04022. [Google Scholar] [CrossRef]
  12. Akerib, D.; Bai, X.; Bedikian, S.; Bernard, E.; Bernstein, A.; Bolozdynya, A.; Bradley, A.; Byram, D.; Cahn, S.; Camp, C.; et al. The Large Underground Xenon (LUX) experiment. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2013, 704, 111–126. [Google Scholar] [CrossRef]
  13. Albert, J.B.; Auty, D.J.; Barbeau, P.S.; Beauchamp, E.; Beck, D.; Belov, V.; Benitez-Medina, C.; Bonatt, J.; Breidenbach, M.; Brunner, T.; et al. Search for Majorana neutrinos with the first two years of EXO-200 data. Nature 2014, 510, 229–234. [Google Scholar]
  14. Fernandes, L.M.P.; Freitas, E.D.C.; Ball, M.; Gómez-Cadenas, J.J.; Monteiro, C.M.B.; Yahlali, N.; Nygren, D.; Santos, J.M.F. Primary and secondary scintillation measurements in a Xenon Gas Proportional Scintillation Counter. J. Instrum. 2010, 5, P09006. [Google Scholar] [CrossRef]
  15. Szydagis, M.; Andaloro, S.; Cutter, J.; Jimenez, G.; Kozlova, E.S.; Ni, K.; Rischbieter, G.R.C.; Tripathi, M.; Velan, V.; Walsh, N.; et al. NEST: Noble Element Simulation Technique, A Symphony of Scintillation. 2020 UC Davis. Available online: http://nest.physics.ucdavis.edu (accessed on 18 March 2021).
  16. Faham, C.; Gehman, V.; Currie, A.; Dobi, A.; Sorensen, P.; Gaitskell, R. Measurements of wavelength-dependent double photoelectron emission from single photons in VUV-sensitive photomultiplier tubes. J. Instrum. 2015, 10, P09010. [Google Scholar] [CrossRef]
  17. Aprile, E.; Arisaka, K.; Arneodo, F.; Askin, A.; Baudis, L.; Behrens, A.; Bokeloh, K.; Brown, E.; Cardoso, J.M.R.; Choi, B.; et al. First Dark Matter Results from the XENON100 Experiment. Phys. Rev. Lett. 2010, 105, 131302. [Google Scholar] [CrossRef]
  18. Akerib, D.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; Boulton, E.; et al. Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX Data. Phys. Rev. Lett. 2016, 116, 161301. [Google Scholar] [CrossRef]
  19. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Results from a Search for Dark Matter in the Complete LUX Exposure. Phys. Rev. Lett. 2017, 118, 021303. [Google Scholar] [CrossRef] [PubMed]
  20. Abe, K.; Hieda, K.; Hiraide, K.; Hirano, S.; Kishimoto, Y.; Ichimura, K.; Kobayashi, K.; Moriyama, S.; Nakagawa, K.; Nakahata, M.; et al. Search for Bosonic Superweakly Interacting Massive Dark Matter Particles with the XMASS-I Detector. Phys. Rev. Lett. 2014, 113, 121301. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  21. Hackett, B.R. The DarkSide-50 Experiment: Electron Recoil Calibrations and A Global Energy Variable. Ph.D. Thesis, University of Hawaii, Manoa, HI, USA, 2017. [Google Scholar] [CrossRef]
  22. Agnes, P. Direct Search for Dark Matter with the DarkSide Experiment. Ph.D. Thesis, APC, Paris, France, 2016. [Google Scholar]
  23. Pagani, L. Direct Dark Matter Detection with the DarkSide-50 Experiment. Ph.D. Thesis, University of Genoa, Genova, Italy, 2017. [Google Scholar]
  24. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Balajthy, J.; Baxter, A.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; Boulton, E.; et al. Improved modeling of beta electronic recoils in liquid xenon using LUX calibration data. J. Instrum. 2020, 15, T02007. [Google Scholar] [CrossRef] [Green Version]
  25. Boulton, E. Applications of Two-Phase Xenon Time Projection Chambers: Searching for Dark Matter and Special Nuclear Materials. Ph.D. Thesis, Yale University, New Haven, CT, USA, 2019. [Google Scholar]
  26. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Kr83m calibration of the 2013 LUX dark matter search. Phys. Rev. D 2017, 96, 112009. [Google Scholar] [CrossRef] [Green Version]
  27. Akerib, D.S.; Alsum, S.; Araújo, H.M.; Bai, X.; Bailey, A.J.; Balajthy, J.; Beltrame, P.; Bernard, E.P.; Bernstein, A.; Biesiadzinski, T.P.; et al. Low-energy (0.7–74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics. arXiv 2016, arXiv:1608.05381. [Google Scholar]
  28. Sarkis, Y.; Aguilar-Arevalo, A.; D’Olivo, J.C. Study of the ionization efficiency for nuclear recoils in pure crystals. Phys. Rev. D 2020, 101, 102001. [Google Scholar] [CrossRef]
  29. Angle, J.; Aprile, E.; Arneodo, F.; Baudis, L.; Bernstein, A.; Bolozdynya, A.; Brusov, P.; Coelho, L.C.C.; Dahl, C.E.; DeViveiros, L.; et al. First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory. Phys. Rev. Lett. 2008, 100, 021303. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  30. Manzur, A.; Curioni, A.; Kastens, L.; McKinsey, D.; Ni, K.; Wongjirad, T. Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV. Phys. Rev. C 2010, 81, 025808. [Google Scholar] [CrossRef]
  31. Plante, G.; Aprile, E.; Budnik, R.; Choi, B.; Giboni, K.L.; Goetzke, L.W.; Lang, R.F.; Lim, K.E.; Melgarejo Fernandez, A.J. New measurement of the scintillation efficiency of low-energy nuclear recoils in liquid xenon. Phys. Rev. C 2011, 84, 045805. [Google Scholar] [CrossRef] [Green Version]
  32. Szydagis, M.; Barry, N.; Kazkaz, K.; Mock, J.; Stolp, D.; Sweany, M.; Tripathi, M.; Uvarov, S.; Walsh, N.; Woods, M. NEST: A comprehensive model for scintillation yield in liquid xenon. J. Instrum. 2011, 6, P10002. [Google Scholar] [CrossRef] [Green Version]
  33. Aprile, E.; Budnik, R.; Choi, B.; Contreras, H.A.; Giboni, K.L.; Goetzke, L.W.; Koglin, J.E.; Lang, R.F.; Lim, K.E.; Melgarejo Fernandez, A.J.; et al. Measurement of the scintillation yield of low-energy electrons in liquid xenon. Phys. Rev. D 2012, 86, 112004. [Google Scholar] [CrossRef] [Green Version]
  34. Szydagis, M.; Fyhrie, A.; Thorngren, D.; Tripathi, M. Enhancement of NEST capabilities for simulating low-energy recoils in liquid xenon. J. Instrum. 2013, 8, C10003. [Google Scholar] [CrossRef] [Green Version]
  35. Sorensen, P.; Dahl, C.E. Nuclear recoil energy scale in liquid xenon with application to the direct detection of dark matter. Phys. Rev. D 2011, 83, 063501. [Google Scholar] [CrossRef] [Green Version]
  36. Dahl, C.E. The Physics of Background Discrimination in Liquid Xenon, and First Results from Xenon10 in the Hunt for WIMP Dark Matter. Ph.D. Thesis, Princeton University, Princeton, NJ, USA, 2009. [Google Scholar]
  37. Szydagis, M.; Akerib, D.S.; Araújo, H.M.; Bai, X.; Bailey, A.J.; Balajthy, J.; Bernard, E.; Bernstein, A.; Bradley, A.; Byram, D.; et al. A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment. arXiv 2014, arXiv:1402.3731. [Google Scholar]
  38. Angle, J.; Aprile, E.; Arneodo, F.; Baudis, L.; Bernstein, A.; Bolozdynya, A.I.; Coelho, L.C.C.; Dahl, C.E.; DeViveiros, L.; Ferella, A.D.; et al. Search for Light Dark Matter in XENON10 Data. Phys. Rev. Lett. 2011, 107, 051301. [Google Scholar] [CrossRef] [Green Version]
  39. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Antochi, V.; Angelino, E.; Arneodo, F.; Barge, D.; et al. Light Dark Matter Search with Ionization Signals in XENON1T. Phys. Rev. Lett. 2019, 123. [Google Scholar] [CrossRef] [Green Version]
  40. Aprile, E.; Angle, J.; Arneodo, F.; Baudis, L.; Bernstein, A.; Bolozdynya, A.; Brusov, P.; Coelho, L.; Dahl, C.; DeViveiros, L.; et al. Design and performance of the XENON10 dark matter experiment. Astropart. Phys. 2011, 34, 679–698. [Google Scholar] [CrossRef] [Green Version]
  41. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.D.; Antochi, V.C.; Angelino, E.; Angevaare, J.; Arneodo, F.; et al. Energy resolution and linearity of XENON1T in the MeV energy range. Eur. Phys. J. C 2020, 80. [Google Scholar] [CrossRef]
  42. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Antochi, V.; Angelino, E.; Angevaare, J.; Arneodo, F.; et al. Excess electronic recoil events in XENON1T. Phys. Rev. D 2020, 102. [Google Scholar] [CrossRef]
  43. Obodovskii, I.; Ospanov, K. Scintillation output of liquid xenon for low-energy gamma-quanta. Instrum. Exp. Tech. 1994, 37, 42–45. [Google Scholar]
  44. Aprile, E.; Giboni, K.L.; Majewski, P.; Ni, K.; Yamashita, M.; Hasty, R.; Manzur, A.; McKinsey, D.N. Scintillation response of liquid xenon to low energy nuclear recoils. Phys. Rev. D 2005, 72, 072006. [Google Scholar] [CrossRef] [Green Version]
  45. Aprile, E.; Dahl, C.E.; de Viveiros, L.; Gaitskell, R.J.; Giboni, K.L.; Kwong, J.; Majewski, P.; Ni, K.; Shutt, T.; Yamashita, M. Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon for a Dark Matter Experiment. Phys. Rev. Lett. 2006, 97, 081302. [Google Scholar] [CrossRef] [Green Version]
  46. Baudis, L.; Dujmovic, H.; Geis, C.; James, A.; Kish, A.; Manalaysay, A.; Marrodán Undagoitia, T.; Schumann, M. Response of liquid xenon to Compton electrons down to 1.5 keV. Phys. Rev. D 2013, 87. [Google Scholar] [CrossRef] [Green Version]
  47. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Anthony, M.; Arneodo, F.; Baudis, L.; Bauermeister, B.; et al. Dark Matter Search Results from a One Ton-Year Exposure of XENON1T. Phys. Rev. Lett. 2018, 121, 111302. [Google Scholar] [CrossRef] [Green Version]
  48. Szydagis, M.; Balajthy, J.; Brodsky, J.; Cutter, J.; Huang, J.; Kozlova, E.; Lenardo, B.; Manalaysay, A.; McKinsey, D.; Mooney, M.; et al. Noble Element Simulation Technique. 2018 Zenodo. Available online: https://zenodo.org/record/4062516#.YFIAFS2ZO8o (accessed on 18 March 2021). [CrossRef]
  49. Akerib, D.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Bedikian, S.; Bernard, E.; Bernstein, A.; Bolozdynya, A.; Bradley, A.; et al. First Results from the LUX Dark Matter Experiment at the Sanford Underground Research Facility. Phys. Rev. Lett. 2014, 112, 091303. [Google Scholar] [CrossRef] [Green Version]
  50. Yahlali, N.; Ball, M.; Cárcel, S.; Díaz, J.; Gil, A.; Gómez Cadenas, J.; Martín-Albo, J.; Monrabal, F.; Serra, L.; Sorel, M. NEXT: Neutrino Experiment with high pressure Xenon gas TPC. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2010, 617, 520–522. [Google Scholar] [CrossRef]
  51. Conti, E.; DeVoe, R.; Gratta, G.; Koffas, T.; Waldman, S.; Wodin, J.; Akimov, D.; Bower, G.; Breidenbach, M.; Conley, R.; et al. Correlated fluctuations between luminescence and ionization in liquid xenon. Phys. Rev. B 2003, 68, 054201. [Google Scholar] [CrossRef] [Green Version]
  52. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Signal yields, energy resolution, and recombination fluctuations in liquid xenon. Phys. Rev. D 2017, 95, 012008. [Google Scholar] [CrossRef] [Green Version]
  53. Akerib, D.S.; Alsum, S.; Araújo, H.M.; Bai, X.; Balajthy, J.; Baxter, A.; Bernard, E.P.; Bernstein, A.; Biesiadzinski, T.P.; Boulton, E.M.; et al. Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers. arXiv 2020, arXiv:2004.06304. [Google Scholar]
  54. Mock, J.; Barry, N.; Kazkaz, K.; Stolp, D.; Szydagis, M.; Tripathi, M.; Uvarov, S.; Woods, M.; Walsh, N. Modeling pulse characteristics in Xenon with NEST. J. Instrum. 2014, 9, T04002. [Google Scholar] [CrossRef] [Green Version]
  55. Chepel, V.; Araújo, H. Liquid noble gas detectors for low energy particle physics. J. Instrum. 2013, 8, R04001. [Google Scholar] [CrossRef] [Green Version]
  56. Araújo, H. Revised performance parameters of the ZEPLIN-III dark matter experiment. arXiv 2020, arXiv:2007.01683. [Google Scholar]
  57. Akerib, D.S.; Alsum, S.; Araújo, H.M.; Bai, X.; Balajthy, J.; Baxter, A.; Bernard, E.P.; Bernstein, A.; Biesiadzinski, T.P.; Boulton, E.M.; et al. Investigation of background electron emission in the LUX detector. arXiv 2020, arXiv:2004.07791. [Google Scholar]
  58. Szydagis, M.; Levy, C.; Blockinger, G.M.; Kamaha, A.; Parveen, N.; Rischbieter, G.R.C. Investigating the XENON1T Low-Energy Electronic Recoil Excess Using NEST. arXiv 2020, arXiv:2007.00528. [Google Scholar]
  59. Boulton, E.; Bernard, E.; Destefano, N.; Edwards, B.; Gai, M.; Hertel, S.; Horn, M.; Larsen, N.; Tennyson, B.; Wahl, C.; et al. Calibration of a two-phase xenon time projection chamber with a 37Ar source. J. Instrum. 2017, 12, P08004. [Google Scholar] [CrossRef] [Green Version]
  60. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Ultra-low energy calibration of LUX detector using Xe127 electron capture. Phys. Rev. D 2017, 96. [Google Scholar] [CrossRef] [Green Version]
  61. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; et al. Signal yields of keV electronic recoils and their discrimination from nuclear recoils in liquid xenon. Phys. Rev. D 2018, 97, 092007. [Google Scholar] [CrossRef] [Green Version]
  62. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Calibration, event reconstruction, data analysis, and limit calculation for the LUX dark matter experiment. Phys. Rev. D 2018, 97, 102008. [Google Scholar] [CrossRef] [Green Version]
  63. Cutter, J. The Noble Element Simulation Technique v2; NorCal HEP-EXchange; 2017 Indico. Available online: indico.physics.lbl.gov/event/560/contributions/1332/attachments/1209/1341/cutter_nest_norcal_2017.pdf (accessed on 18 March 2021).
  64. Akerib, D.; Alsum, S.; Aquino, C.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; et al. First Searches for Axions and Axionlike Particles with the LUX Experiment. Phys. Rev. Lett. 2017, 118, 261301. [Google Scholar] [CrossRef]
  65. Goetzke, L.; Aprile, E.; Anthony, M.; Plante, G.; Weber, M. Measurement of light and charge yield of low-energy electronic recoils in liquid xenon. Phys. Rev. D 2017, 96, 103007. [Google Scholar] [CrossRef] [Green Version]
  66. Aprile, E.; Agostini, F.; Alfonsi, M.; Arisaka, K.; Arneodo, F.; Auger, M.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; et al. First axion results from the XENON100 experiment. Phys. Rev. D 2014, 90, 062009. [Google Scholar] [CrossRef] [Green Version]
  67. Akerib, D.; Bai, X.; Bedikian, S.; Bernard, E.; Bernstein, A.; Bradley, A.; Cahn, S.; Carmona-Benitez, M.; Carr, D.; Chapman, J.; et al. LUXSim: A component-centric approach to low-background simulations. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2012, 675, 63–77. [Google Scholar] [CrossRef] [Green Version]
  68. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Antochi, V.; Arneodo, F.; Baudis, L.; Bauermeister, B.; et al. XENON1T dark matter data analysis: Signal and background models and statistical inference. Phys. Rev. D 2019, 99, 112009. [Google Scholar] [CrossRef] [Green Version]
  69. Bloch, I.M.; Caputo, A.; Essig, R.; Redigolo, D.; Sholapurkar, M.; Volansky, T. Exploring New Physics with O(keV) Electron Recoils in Direct Detection Experiments. arXiv 2020, arXiv:2006.14521. [Google Scholar]
  70. Delaquis, S.; Jewell, M.; Ostrovskiy, I.; Weber, M.; Ziegler, T.; Dalmasson, J.; Kaufman, L.; Richards, T.; Albert, J.; Anton, G.; et al. Deep neural networks for energy and position reconstruction in EXO-200. J. Instrum. 2018, 13, P08023. [Google Scholar] [CrossRef] [Green Version]
  71. Carrara, N.; Ernst, J.A. On the Upper Limit of Separability. arXiv 2017, arXiv:1708.09449. [Google Scholar]
  72. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector. Phys. Rev. D 2018, 97, 112002. [Google Scholar] [CrossRef] [Green Version]
  73. Akerib, D.; Bai, X.; Bernard, E.; Bernstein, A.; Bradley, A.; Byram, D.; Cahn, S.; Carmona-Benitez, M.; Chapman, J.; Coffey, T.; et al. Technical results from the surface run of the LUX dark matter experiment. Astropart. Phys. 2013, 45, 34–43. [Google Scholar] [CrossRef] [Green Version]
  74. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Balajthy, J.; Baxter, A.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Extending light WIMP searches to single scintillation photons in LUX. Phys. Rev. D 2020, 101, 042001. [Google Scholar] [CrossRef] [Green Version]
  75. Manalaysay, A.; Undagoitia, T.M.; Askin, A.; Baudis, L.; Behrens, A.; Ferella, A.D.; Kish, A.; Lebeda, O.; Santorelli, R.; Vénos, D.; et al. Spatially uniform calibration of a liquid xenon detector at low energies using 83mKr. Rev. Sci. Instrum. 2010, 81, 073303. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  76. Akerib, D.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; Boulton, E.; et al. Tritium calibration of the LUX dark matter experiment. Phys. Rev. D 2016, 93, 072009. [Google Scholar] [CrossRef] [Green Version]
  77. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. 3D modeling of electric fields in the LUX detector. J. Instrum. 2017, 12, P1102. [Google Scholar] [CrossRef] [Green Version]
  78. Doke, T.; Hitachi, A.; Kikuchi, J.; Masuda, K.; Okada, H.; Shibamura, E. Absolute Scintillation Yields in Liquid Argon and Xenon for Various Particles. Jpn. J. Appl. Phys. 2002, 41, 1538–1545. [Google Scholar] [CrossRef]
  79. Dobi, A. Measurement of the Electron Recoil Band of the LUX Dark Matter Detector With a Tritium Calibration Source. Ph.D. Thesis, The University of Maryland, College Park, MD, USA, 2014. [Google Scholar] [CrossRef]
  80. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Antochi, V.; Arneodo, F.; Baudis, L.; Bauermeister, B.; et al. XENON1T dark matter data analysis: Signal reconstruction, calibration, and event selection. Phys. Rev. D 2019, 100, 052014. [Google Scholar] [CrossRef] [Green Version]
  81. Lenardo, B.; Xu, J.; Pereverzev, S.; Akindele, O.A.; Naim, D.; Kingston, J.; Bernstein, A.; Kazkaz, K.; Tripathi, M.; Awe, C.; et al. Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3–6 keV with single-ionization-electron sensitivity. arXiv 2019, arXiv:1908.00518. [Google Scholar]
  82. Auger, M.; Auty, D.J.; Barbeau, P.S.; Beauchamp, E.; Belov, V.; Benitez-Medina, C.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cleveland, B.; et al. Search for Neutrinoless Double-Beta Decay in Xe136 with EXO-200. Phys. Rev. Lett. 2012, 109, 032505. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  83. Akerib, D.S.; Akerlof, C.W.; Alqahtani, A.; Alsum, S.K.; Anderson, T.J.; Angelides, N.; Araújo, H.M.; Armstrong, J.E.; Arthurs, M.; Bai, X.; et al. Projected sensitivity of the LUX-ZEPLIN experiment to the 0neutrinoBetaBeta decay of Xe136. Phys. Rev. C 2020, 102, 014602. [Google Scholar] [CrossRef]
  84. Aprile, E.; Alfonsi, M.; Arisaka, K.; Arneodo, F.; Balan, C.; Baudis, L.; Behrens, A.; Beltrame, P.; Bokeloh, K.; Brown, E.; et al. Analysis of the XENON100 dark matter search data. Astropart. Phys. 2014, 54, 11–24. [Google Scholar] [CrossRef] [Green Version]
  85. Ackerman, N.; Aharmim, B.; Auger, M.; Auty, D.J.; Barbeau, P.S.; Barry, K.; Bartoszek, L.; Beauchamp, E.; Belov, V.; Benitez-Medina, C.; et al. Observation of Two-Neutrino Double-Beta Decay in Xe136 with the EXO-200 Detector. Phys. Rev. Lett. 2011, 107, 212501. [Google Scholar] [CrossRef] [PubMed]
  86. Davis, C.; Hall, C.; Albert, J.; Barbeau, P.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G.; et al. An optimal energy estimator to reduce correlated noise for the EXO-200 light readout. J. Instrum. 2016, 11, P07015. [Google Scholar] [CrossRef] [Green Version]
  87. Albert, J.B.; Auger, M.; Auty, D.J.; Barbeau, P.S.; Beauchamp, E.; Beck, D.; Belov, V.; Benitez-Medina, C.; Bonatt, J.; Breidenbach, M.; et al. An improved measurement of the 2nuBetaBeta half-life of 136Xe with the EXO-200 detector. Phys. Rev. C 2014, 89, 015502. [Google Scholar] [CrossRef] [Green Version]
  88. Albert, J.; Anton, G.; Badhrees, I.; Barbeau, P.; Bayerlein, R.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Cao, G.; et al. Searches for double beta decay of Xe134 with EXO-200. Phys. Rev. D 2017, 96, 092001. [Google Scholar] [CrossRef] [Green Version]
  89. Auger, M.; Auty, D.J.; Barbeau, P.S.; Bartoszek, L.; Baussan, E.; Beauchamp, E.; Benitez-Medina, C.; Breidenbach, M.; Chauhan, D.; Cleveland, B.; et al. The EXO-200 detector, part I: Detector design and construction. J. Instrum. 2012, 7, P05010. [Google Scholar] [CrossRef] [Green Version]
  90. Albert, J.B.; Auty, D.J.; Barbeau, P.S.; Beck, D.; Belov, V.; Benitez-Medina, C.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G.F.; et al. Investigation of radioactivity-induced backgrounds in EXO-200. Phys. Rev. C 2015, 92, 015503. [Google Scholar] [CrossRef] [Green Version]
  91. Albert, J.; Auty, D.; Barbeau, P.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G.; Chambers, C.; et al. Cosmogenic backgrounds to ZeroNuBetaBeta in EXO-200. J. Cosmol. Astropart. Phys. 2016, 2016, 029. [Google Scholar] [CrossRef]
  92. Albert, J.; Barbeau, P.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Burenkov, A.; Cao, G.; Chambers, C.; Cleveland, B.; et al. First search for Lorentz and CPT violation in double beta decay with EXO-200. Phys. Rev. D 2016, 93, 072001. [Google Scholar] [CrossRef] [Green Version]
  93. Leonard, D.; Auty, D.; Didberidze, T.; Gornea, R.; Grinberg, P.; MacLellan, R.; Methven, B.; Piepke, A.; Vuilleumier, J.L.; Albert, J.; et al. Trace radioactive impurities in final construction materials for EXO-200. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2017, 871, 169–179. [Google Scholar] [CrossRef] [Green Version]
  94. Albert, J.; Anton, G.; Badhrees, I.; Barbeau, P.; Bayerlein, R.; Beck, D.; Belov, V.; Breidenbach, M.; Brunner, T.; Cao, G.; et al. Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector. Phys. Rev. Lett. 2018, 120, 072701. [Google Scholar] [CrossRef] [Green Version]
  95. The KamLAND-Zen Collaboration. Results from KamLAND-Zen. arXiv 2014, arXiv:1409.0077. [Google Scholar]
  96. Shirai, J. KamLAND-Zen Experiment. Proc. Sci. 2018, HQL2018. [Google Scholar] [CrossRef] [Green Version]
  97. Asakura, K.; Gando, A.; Gando, Y.; Hachiya, T.; Hayashida, S.; Ikeda, H.; Inoue, K.; Ishidoshiro, K.; Ishikawa, T.; Ishio, S.; et al. Search for double-beta decay of 136Xe to excited states of 136Ba with the KamLAND-Zen experiment. Nucl. Phys. A 2016, 946, 171–181. [Google Scholar] [CrossRef] [Green Version]
  98. Gando, A.; Gando, Y.; Hanakago, H.; Ikeda, H.; Inoue, K.; Ishidoshiro, K.; Kato, R.; Koga, M.; Matsuda, S.; Mitsui, T.; et al. Limit on Neutrinoless Beta Beta Decay of Xe136 from the First Phase of KamLAND-Zen and Comparison with the Positive Claim in Ge76. Phys. Rev. Lett. 2013, 110. [Google Scholar] [CrossRef] [Green Version]
  99. Gando, A.; Gando, Y.; Hanakago, H.; Ikeda, H.; Inoue, K.; Kato, R.; Koga, M.; Matsuda, S.; Mitsui, T.; Nakada, T.; et al. Limits on Majoron-emitting Double-Beta Decays of 136Xe in the KamLAND-Zen experiment. Phys. Rev. C 2012, 86, 021601. [Google Scholar] [CrossRef] [Green Version]
  100. Gando, A.; Gando, Y.; Hanakago, H.; Ikeda, H.; Inoue, K.; Kato, R.; Koga, M.; Matsuda, S.; Mitsui, T.; Nakada, T.; et al. Measurement of the double-beta decay half-life of 136Xe with the KamLAND-Zen experiment. Phys. Rev. C 2012, 85, 045504. [Google Scholar] [CrossRef] [Green Version]
  101. Gando, A.; Gando, Y.; Hachiya, T.; Hayashi, A.; Hayashida, S.; Ikeda, H.; Inoue, K.; Ishidoshiro, K.; Karino, Y.; Koga, M.; et al. Search for Majorana Neutrinos Near the Inverted Mass Hierarchy Region with KamLAND-Zen. Phys. Rev. Lett. 2016, 117, 082503. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  102. Leonard, D.S.; Grinberg, P.; Weber, P.; Baussan, E.; Djurcic, Z.; Keefer, G.; Piepke, A.; Pocar, A.; Vuilleumier, J.L.; Vuilleumier, J.M.; et al. Systematic study of trace radioactive impurities in candidate construction materials for EXO-200. arXiv 2008, arXiv:0709.4524. [Google Scholar] [CrossRef] [Green Version]
  103. Gallina, G.; Giampa, P.; Retière, F.; Kroeger, J.; Zhang, G.; Ward, M.; Margetak, P.; Li, G.; Tsang, T.; Doria, L.; et al. Characterization of the Hamamatsu VUV4 MPPCs for nEXO. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2019, 940, 371–379. [Google Scholar] [CrossRef] [Green Version]
  104. Nakarmi, P.; Ostrovskiy, I.; Soma, A.; Retière, F.; Kharusi, S.A.; Alfaris, M.; Anton, G.; Arnquist, I.; Badhrees, I.; Barbeau, P.; et al. Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon. J. Instrum. 2020, 15, P01019. [Google Scholar] [CrossRef] [Green Version]
  105. Akerib, D.; Bai, X.; Bernard, E.; Bernstein, A.; Bradley, A.; Byram, D.; Cahn, S.; Carmona-Benitez, M.; Carr, D.; Chapman, J.; et al. An ultra-low background PMT for liquid xenon detectors. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2013, 703, 1–6. [Google Scholar] [CrossRef] [Green Version]
  106. Aprile, E.; Agostini, F.; Alfonsi, M.; Arazi, L.; Arisaka, K.; Arneodo, F.; Auger, M.; Balan, C.; Barrow, P.; Baudis, L.; et al. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment. Eur. Phys. J. C 2015, 75, 1–10. [Google Scholar] [CrossRef] [Green Version]
  107. Álvarez, V.; Borges, F.I.G.M.; Cárcel, S.; Castel, J.; Cebrián, S.; Cervera, A.; Conde, C.A.N.; Dafni, T.; Dias, T.H.V.T.; Diaz, J.; et al. Near-Intrinsic Energy Resolution for 30 to 662 keV Gamma Rays in a High Pressure Xenon Electroluminescent TPC. Nucl. Instrum. Meth. A 2013, 708, 101–114. [Google Scholar] [CrossRef] [Green Version]
  108. Lorca, D.; Martín-Albo, J.; Laing, A.; Ferrario, P.; Gómez-Cadenas, J.J.; Álvarez, V.; Borges, F.I.G.; Camargo, M.; Cárcel, S.; Cebrián, S.; et al. Characterisation of NEXT-DEMO using xenon KαX-rays. J. Instrum. 2014, 9, P10007. [Google Scholar] [CrossRef] [Green Version]
  109. Aprile, E.; Mukherjee, R.; Suzuki, M. Performance of a liquid xenon ionization chamber irradiated with electrons and gamma-rays. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 1991, 302, 177–185. [Google Scholar] [CrossRef]
  110. Anton, G.; Badhrees, I.; Barbeau, P.S.; Beck, D.; Belov, V.; Bhatta, T.; Breidenbach, M.; Brunner, T.; Cao, G.F.; Cen, W.R.; et al. Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment. Phys. Rev. C 2020, 101, 065501. [Google Scholar] [CrossRef]
  111. Lebedenko, V.N.; Araújo, H.M.; Barnes, E.J.; Bewick, A.; Cashmore, R.; Chepel, V.; Currie, A.; Davidge, D.; Dawson, J.; Durkin, T.; et al. Results from the first science run of the ZEPLIN-III dark matter search experiment. Phys. Rev. D 2009, 80, 052010. [Google Scholar] [CrossRef] [Green Version]
  112. Aprile, E.; Bolotnikov, A.E.; Bolozdynya, A.I.; Doke, T. Front Matter. In Noble Gas Detectors; John Wiley & Sons, Ltd.: Hoboken, NJ, USA, 2006; pp. I–XVI. [Google Scholar] [CrossRef]
  113. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Balajthy, J.; Baxter, A.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; et al. Improved measurements of the beta-decay response of liquid xenon with the LUX detector. Phys. Rev. D 2019, 100, 022002. [Google Scholar] [CrossRef] [Green Version]
  114. You, L. Superconducting nanowire single-photon detectors for quantum information. Nanophotonics 2020, 9, 2673–2692. [Google Scholar] [CrossRef]
  115. Kravitz, S.; Smith, R.; Hagaman, L.; Bernard, E.; Mckinsey, D.; Rudd, L.; Tvrznikova, L.; Gann, G.; Sakai, M. Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX. Eur. Phys. J. C 2019, 80, 1–20. [Google Scholar] [CrossRef]
  116. Escobar, C.O.; Rubinov, P.; Tilly, E. Near-infrared scintillation of liquid argon: Recent results obtained with the NIR facility at Fermilab. J. Instrum. 2018, 13, C03031. [Google Scholar] [CrossRef] [Green Version]
  117. Araújo, H.; Akimov, D.; Barnes, E.; Belov, V.; Bewick, A.; Burenkov, A.; Chepel, V.; Currie, A.; DeViveiros, L.; Edwards, B.; et al. Radioactivity backgrounds in ZEPLIN–III. Astropart. Phys. 2012, 35, 495–502. [Google Scholar] [CrossRef] [Green Version]
  118. Akerib, D.; Araújo, H.; Bai, X.; Bailey, A.; Balajthy, J.; Bernard, E.; Bernstein, A.; Bradley, A.; Byram, D.; Cahn, S.; et al. Radiogenic and muon-induced backgrounds in the LUX dark matter detector. Astropart. Phys. 2015, 62, 33–46. [Google Scholar] [CrossRef] [Green Version]
  119. Li, S.; Chen, X.; Cui, X.; Fu, C.; Ji, X.; Lin, Q.; Liu, J.; Liu, X.; Tan, A.; Wang, X.; et al. Krypton and radon background in the PandaX-I dark matter experiment. J. Instrum. 2017, 12, T02002. [Google Scholar] [CrossRef] [Green Version]
  120. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F.D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; et al. Intrinsic backgrounds from Rn and Kr in the XENON100 experiment. Eur. Phys. J. C 2018, 78. [Google Scholar] [CrossRef] [Green Version]
  121. Aprile, E.; Anthony, M.; Lin, Q.; Greene, Z.; de Perio, P.; Gao, F.; Howlett, J.; Plante, G.; Zhang, Y.; Zhu, T. Simultaneous measurement of the light and charge response of liquid xenon to low-energy nuclear recoils at multiple electric fields. Phys. Rev. D 2018, 98. [Google Scholar] [CrossRef] [Green Version]
  122. Huang, D. Ultra-Low Energy Calibration of the LUX and LZ Dark Matter Detectors. Ph.D. Thesis, Brown University, Providence, RI, USA, 2020. [Google Scholar] [CrossRef]
  123. Edwards, B.; Bernard, E.; Boulton, E.; Destefano, N.; Gai, M.; Horn, M.; Larsen, N.; Tennyson, B.; Tvrznikova, L.; Wahl, C.; et al. Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber. J. Instrum. 2018, 13, P01005. [Google Scholar] [CrossRef] [Green Version]
  124. Xu, J.; Pereverzev, S.; Lenardo, B.; Kingston, J.; Naim, D.; Bernstein, A.; Kazkaz, K.; Tripathi, M. Electron extraction efficiency study for dual-phase xenon dark matter experiments. Phys. Rev. D 2019, 99. [Google Scholar] [CrossRef] [Green Version]
  125. Sorensen, P.; Manzur, A.; Dahl, C.; Angle, J.; Aprile, E.; Arneodo, F.; Baudis, L.; Bernstein, A.; Bolozdynya, A.; Coelho, L.; et al. The scintillation and ionization yield of liquid xenon for nuclear recoils. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2009, 601, 339–346. [Google Scholar] [CrossRef] [Green Version]
  126. Sorensen, P. A coherent understanding of low-energy nuclear recoils in liquid xenon. J. Cosmol. Astropart. Phys. 2010, 2010, 033. [Google Scholar] [CrossRef]
  127. Sorensen, P.; Angle, J.; Aprile, E.; Arneodo, F.; Baudis, L.; Bernstein, A.; Bolozdynya, A.; Brusov, P.; Coelho, L.C.C.; Dahl, C.E.; et al. Lowering the low-energy threshold of xenon detectors. arXiv 2010, arXiv:1011.6439. [Google Scholar]
  128. Horn, M.; Belov, V.; Akimov, D.; Araújo, H.; Barnes, E.; Burenkov, A.; Chepel, V.; Currie, A.; Edwards, B.; Ghag, C.; et al. Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data. Phys. Lett. B 2011, 705, 471–476. [Google Scholar] [CrossRef]
  129. Aprile, E.; Alfonsi, M.; Arisaka, K.; Arneodo, F.; Balan, C.; Baudis, L.; Bauermeister, B.; Behrens, A.; Beltrame, P.; Bokeloh, K.; et al. Response of the XENON100 dark matter detector to nuclear recoils. Phys. Rev. D 2013, 88, 012006. [Google Scholar] [CrossRef] [Green Version]
  130. Yan, B.; Abdukerim, A.; Chen, W.; Chen, X.; Chen, Y.; Cheng, C.; Cui, X.; Fan, Y.; Fang, D.; Fu, C.; et al. Determination of responses of liquid xenon to low energy electron and nuclear recoils using the PandaX-II detector. arXiv 2021, arXiv:2102.09158v1. [Google Scholar]
  131. Hitachi, A. Properties of liquid xenon scintillation for dark matter searches. Astropart. Phys. 2005, 24, 247–256. [Google Scholar] [CrossRef] [Green Version]
  132. Sorensen, P. Atomic limits in the search for galactic dark matter. Phys. Rev. D 2015, 91, 083509. [Google Scholar] [CrossRef] [Green Version]
  133. Bezrukov, F.; Kahlhoefer, F.; Lindner, M. Interplay between scintillation and ionization in liquid xenon Dark Matter searches. Astropart. Phys. 2011, 35, 119–127. [Google Scholar] [CrossRef] [Green Version]
  134. Mu, W.; Xiong, X.; Ji, X. Scintillation Efficiency for Low-Energy Nuclear Recoils in Liquid-Xenon Dark Matter Detectors. arXiv 2013, arXiv:1306.0170. [Google Scholar] [CrossRef] [Green Version]
  135. Mu, W.; Ji, X. Ionization Yield from Nuclear Recoils in Liquid-Xenon Dark Matter Detection. arXiv 2013, arXiv:1310.2094. [Google Scholar] [CrossRef] [Green Version]
  136. Aprile, E.; Alfonsi, M.; Arisaka, K.; Arneodo, F.; Balan, C.; Baudis, L.; Bauermeister, B.; Behrens, A.; Beltrame, P.; Bokeloh, K.; et al. The neutron background of the XENON100 dark matter search experiment. J. Phys. G Nucl. Part. Phys. 2013, 40, 115201. [Google Scholar] [CrossRef] [Green Version]
  137. Aprile, E.; Arisaka, K.; Arneodo, F.; Askin, A.; Baudis, L.; Behrens, A.; Bokeloh, K.; Brown, E.; Cardoso, J.M.R.; Choi, B.; et al. Study of the electromagnetic background in the XENON100 experiment. arXiv 2013, arXiv:1101.3866. [Google Scholar] [CrossRef] [Green Version]
  138. Akerib, D.; Akerlof, C.; Alsum, S.; Angelides, N.; Araújo, H.; Armstrong, J.; Arthurs, M.; Bai, X.; Balajthy, J.; Balashov, S.; et al. Measurement of the gamma ray background in the Davis cavern at the Sanford Underground Research Facility. Astropart. Phys. 2020, 116, 102391. [Google Scholar] [CrossRef] [Green Version]
  139. Lewin, J.; Smith, P. Review of mathematics, numerical factors, and corrections for dark matter experiments based on elastic nuclear recoil. Astropart. Phys. 1996, 6, 87–112. [Google Scholar] [CrossRef] [Green Version]
  140. Verbus, J.R. An Absolute Calibration of Sub-1 keV Nuclear Recoils in Liquid Xenon Using D-D Neutron Scattering Kinematics in the LUX Detector. Ph.D. Thesis, Brown University, Providence, RI, USA, 2016. [Google Scholar] [CrossRef]
  141. Wang, L.; Mei, D.M. A comprehensive study of low-energy response for xenon-based dark matter experiments. J. Phys. G Nucl. Part. Phys. 2017, 44, 055001. [Google Scholar] [CrossRef] [Green Version]
  142. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.; Antochi, V.; Angelino, E.; Arneodo, F.; Barge, D.; et al. Search for Light Dark Matter Interactions Enhanced by the Migdal Effect or Bremsstrahlung in XENON1T. Phys. Rev. Lett. 2019, 123, 241803. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  143. Lindhard, J. Range Concepts and Heavy Ion Ranges; Munksgaard: Copenhagen, Denmark, 1963; Volume 33. [Google Scholar]
  144. Lenardo, B.; Kazkaz, K.; Manalaysay, A.; Mock, J.; Szydagis, M.; Tripathi, M. A Global Analysis of Light and Charge Yields in Liquid Xenon. IEEE Trans. Nucl. Sci. 2015, 62, 3387–3396. [Google Scholar] [CrossRef] [Green Version]
  145. Akerib, D.; Alsum, S.; Araújo, H.; Bai, X.; Balajthy, J.; Beltrame, P.; Bernard, E.; Bernstein, A.; Biesiadzinski, T.; Boulton, E.; et al. Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data. Phys. Rev. Lett. 2019, 122, 131301. [Google Scholar] [CrossRef] [Green Version]
  146. Akimov, D.; Albert, J.B.; An, P.; Awe, C.; Barbeau, P.S.; Becker, B.; Belov, V.; Brown, A.; Bolozdynya, A.; Cabrera-Palmer, B.; et al. Observation of Coherent Elastic Neutrino-Nucleus Scattering. Science 2017, 357, 1123–1126. [Google Scholar] [CrossRef] [Green Version]
  147. Akimov, D.; Albert, J.B.; An, P.; Awe, C.; Barbeau, P.S.; Becker, B.; Belov, V.; Blackston, M.A.; Blokland, L.; Bolozdynya, A.; et al. First Detection of Coherent Elastic Neutrino-Nucleus Scattering on Argon. arXiv 2020, arXiv:2003.10630. [Google Scholar]
  148. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F.D.; Antochi, V.C.; Angelino, E.; Angevaare, J.R.; Arneodo, F.; et al. Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment. arXiv 2020, arXiv:2007.08796. [Google Scholar]
  149. Plante, G. The XENON100 Dark Matter Experiment: Design, Construction, Calibration and 2010 Search Results with Improved Measurement of the Scintillation Response of Liquid Xenon to Low-Energy Nuclear Recoils. Ph.D. Thesis, Columbia University, New York, NY, USA, 2012. [Google Scholar]
  150. Akerib, D.; Akerlof, C.; Alqahtani, A.; Alsum, S.; Anderson, T.; Angelides, N.; Araújo, H.; Armstrong, J.; Arthurs, M.; Bai, X.; et al. Simulations of events for the LUX-ZEPLIN (LZ) dark matter experiment. Astropart. Phys. 2021, 125, 102480. [Google Scholar] [CrossRef]
  151. Bernabei, R.; Belli, P.; Cappella, F.; Cerulli, R.; Montecchia, F.; Nozzoli, F.; Incicchitti, A.; Prosperi, D.; Dai, C. The DAMA pure liquid xenon experiment. In International Workshop on Technique and Application of Xenon Detectors; World Scientific: Singapore, 2001; pp. 1–57. [Google Scholar]
  152. Chepel, V.; Solovov, V.; Neves, F.; Pereira, A.; Mendes, P.; Silva, C.; Lindote, A.; da Cunha, P.J.; Lopes, M.; Kossionides, S. Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV. Astropart. Phys. 2006, 26, 58–63. [Google Scholar] [CrossRef] [Green Version]
  153. Verbus, J.R.; Rhyne, C.A.; Malling, D.C.; Genecov, M.; Ghosh, S.; Moskowitz, A.G.; Chan, S.; Chapman, J.J.; de Viveiros, L.; Faham, C.H.; et al. Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics. Nucl. Instrum. Meth. A 2017, 851, 68–81. [Google Scholar] [CrossRef] [Green Version]
  154. Agostinelli, S.; Allison, J.; Amako, K.A.; Apostolakis, J.; Araújo, H.; Arce, P.; Asai, M.; Axen, D.; Banerjee, S.; Barrand, G.; et al. Geant4—A simulation toolkit. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2003, 506, 250–303. [Google Scholar] [CrossRef] [Green Version]
  155. Allison, J.; Amako, K.; Apostolakis, J.E.A.; Araújo, H.A.A.H.; Dubois, P.A.; Asai, M.A.A.M.; Barrand, G.; Capra, R.; Chauvie, S.; Chytracek, R.; et al. Geant4 developments and applications. IEEE Trans. Nucl. Sci. 2006, 53, 270. [Google Scholar] [CrossRef] [Green Version]
  156. Arisaka, K.; Beltrame, P.; Ghag, C.; Lung, K.; Scovell, P. A new analysis method for WIMP searches with dual-phase liquid Xe TPCs. Astropart. Phys. 2012, 37, 51–59. [Google Scholar] [CrossRef] [Green Version]
  157. Lippincott, W.H.; Cahn, S.B.; Gastler, D.; Kastens, L.W.; Kearns, E.; McKinsey, D.N.; Nikkel, J.A. Calibration of liquid argon and neon detectors with Kr83m. Phys. Rev. C 2010, 81, 045803. [Google Scholar] [CrossRef] [Green Version]
  158. Kimura, M.; Aoyama, K.; Tanaka, M.; Yorita, K. Liquid argon scintillation response to electronic recoils between 2.8–1275 keV in a high light yield single-phase detector. Phys. Rev. D 2020, 102, 092008. [Google Scholar] [CrossRef]
  159. Agnes, P.; Alexander, T.; Alton, A.; Arisaka, K.; Back, H.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Brigatti, A.; et al. First results from the DarkSide-50 dark matter experiment at Laboratori Nazionali del Gran Sasso. Phys. Lett. B 2015, 743, 456–466. [Google Scholar] [CrossRef]
  160. Amaudruz, P.A.; Baldwin, M.; Batygov, M.; Beltran, B.; Bina, C.E.; Bishop, D.; Bonatt, J.; Boorman, G.; Boulay, M.G.; Broerman, B.; et al. First results from the DEAP-3600 dark matter search with argon at SNOLAB. arXiv 2018, arXiv:1707.08042. [Google Scholar] [CrossRef] [Green Version]
  161. Gastler, D.; Kearns, E.; Hime, A.; Stonehill, L.C.; Seibert, S.; Klein, J.; Lippincott, W.H.; McKinsey, D.N.; Nikkel, J.A. Measurement of scintillation efficiency for nuclear recoils in liquid argon. Phys. Rev. C 2012, 85, 065811. [Google Scholar] [CrossRef]
  162. Galbiati, C.; Acosta-Kane, D.; Acciarri, R.; Amaize, O.; Antonello, M.; Baibussinov, B.; Ceolin, M.B.; Ballentine, C.J.; Bansal, R.; Basgall, L.; et al. Discovery of underground argon with a low level of radioactive 39Ar and possible applications to WIMP dark matter detectors. J. Phys. Conf. Ser. 2008, 120, 042015. [Google Scholar] [CrossRef]
  163. Abi, B.; Acciarri, R.; Acero, M.A.; Adamov, G.; Adams, D.; Adinolfi, M.; Ahmad, Z.; Ahmed, J.; Alion, T.; Monsalve, S.A.; et al. Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume IV Far Detector Single-phase Technology. JINST 2020, 15, T08010. [Google Scholar] [CrossRef]
  164. Abratenko, P.; Alrashed, M.; An, R.; Anthony, J.; Asaadi, J.; Ashkenazi, A.; Balasubramanian, S.; Baller, B.; Barnes, C.; Barr, G.; et al. The Continuous Readout Stream of the MicroBooNE Liquid Argon Time Projection Chamber for Detection of Supernova Burst Neutrinos. arXiv 2020, arXiv:2008.13761. [Google Scholar]
  165. Abi, B.; Acciarri, R.; Acero, M.A.; Adamov, G.; Adams, D.; Adinolfi, M.; Ahmad, Z.; Ahmed, J.; Alion, T.; Monsalve, S.A.; et al. Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment. arXiv 2020, arXiv:2008.06647. [Google Scholar]
  166. Kimura, M.; Tanaka, M.; Washimi, T.; Yorita, K. Measurement of the scintillation efficiency for nuclear recoils in liquid argon under electric fields up to 3 kV/cm. Phys. Rev. D 2019, 100, 032002. [Google Scholar] [CrossRef] [Green Version]
  167. Kimura, M.; Aoyama, K.; Takeda, T.; Tanaka, M.; Yorita, K. Measurements of argon-scintillation and -electroluminescence properties for low mass WIMP dark matter search. J. Instrum. 2020, 15, C08012. [Google Scholar] [CrossRef]
  168. Doke, T.; Hitachi, A.; Kubota, S.; Nakamoto, A.; Takahashi, T. Estimation of Fano factors in liquid argon, krypton, xenon and xenon-doped liquid argon. Nucl. Instrum. Methods 1976, 134, 353–357. [Google Scholar] [CrossRef]
  169. Doke, T.; Crawford, H.J.; Hitachi, A.; Kikuchi, J.; Lindstrom, P.J.; Masuda, K.; Shibamura, E.; Takahashi, T. LET dependence of scintillation yields in liquid argon. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 1988, 269. [Google Scholar] [CrossRef]
  170. Alexander, T.; Alton, D.; Arisaka, K.; Back, H.O.; Beltrame, P.; Benziger, J.; Bonfini, G.; Brigatti, A.; Brodsky, J.; Bussino, S.; et al. DarkSide search for dark matter. J. Instrum. 2013, 8, C11021. [Google Scholar] [CrossRef]
  171. Sangiorgio, S.; Joshi, T.; Bernstein, A.; Coleman, J.; Foxe, M.; Hagmann, C.; Jovanovic, I.; Kazkaz, K.; Mavrokoridis, K.; Mozin, V.; et al. First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2013, 728, 69–72. [Google Scholar] [CrossRef] [Green Version]
  172. Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; et al. XENON100 dark matter results from a combination of 477 live days. Phys. Rev. D 2016, 94, 122001. [Google Scholar] [CrossRef] [Green Version]
  173. Zani, A. The WArP Experiment: A Double-Phase Argon Detector for Dark Matter Searches. Adv. High Energy Phys. 2014, 2014, 205107. [Google Scholar] [CrossRef] [Green Version]
  174. Agnes, P.; Albuquerque, I.; Alexander, T.; Alton, A.; Araujo, G.; Ave, M.; Back, H.; Baldin, B.; Batignani, G.; Biery, K.; et al. DarkSide-50 532-day dark matter search with low-radioactivity argon. Phys. Rev. D 2018, 98, 102006. [Google Scholar] [CrossRef] [Green Version]
  175. Agnes, P.; Dawson, J.; De Cecco, S.; Fan, A.; Fiorillo, G.; Franco, D.; Galbiati, C.; Giganti, C.; Johnson, T.; Korga, G.; et al. Measurement of the liquid argon energy response to nuclear and electronic recoils. Phys. Rev. D 2018, 97, 112005. [Google Scholar] [CrossRef] [Green Version]
  176. Weinstein, A.; theDUNE Collaboration. Supernova Neutrinos at the DUNE Experiment. J. Phys. Conf. Ser. 2020, 1342, 012052. [Google Scholar] [CrossRef]
  177. Aguilar-Arevalo, A.A.; Anderson, C.E.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; et al. Search for core-collapse supernovae using the MiniBooNE neutrino detector. Phys. Rev. D 2010, 81, 032001. [Google Scholar] [CrossRef] [Green Version]
  178. Acciarri, R.; Acero, M.A.; Adamowski, M.; Adams, C.; Adamson, P.; Adhikari, S.; Ahmad, Z.; Albright, C.H.; Alion, T.; Amador, E.; et al. Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE): Conceptual Design Report, Volume 1: The LBNF and DUNE Projects. arXiv 2016, arXiv:1601.05471. [Google Scholar]
  179. Acciarri, R.; Adams, C.; Asaadi, J.A.; Backfish, M.; Badgett, W.; Baller, B.; Rodrigues, O.B.; Blaszczyk, F.M.; Bouabid, R.; Bromberg, C.; et al. The Liquid Argon In A Testbeam (LArIAT) Experiment. JINST 2020, 15, P04026. [Google Scholar] [CrossRef]
  180. LArIAT Collaboration. Calorimetry for low-energy electrons using charge and light in liquid argon. Phys. Rev. D 2020, 101, 012010. [Google Scholar] [CrossRef] [Green Version]
  181. Adams, C.; Alrashed, M.; An, R.; Anthony, J.; Asaadi, J.; Ashkenazi, A.; Balasubramanian, S.; Baller, B.; Barnes, C.; Barr, G.; et al. Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons. J. Instrum. 2020, 15, P03022. [Google Scholar] [CrossRef] [Green Version]
  182. BIRKS, J. Chapter 8—Organic Liquid scintillators. In The Theory and Practice of Scintillation Counting; BIRKS, J., Ed.; International Series of Monographs in Electronics and Instrumentation; Pergamon Press: Oxford, UK, 1964; pp. 269–320. [Google Scholar] [CrossRef]
  183. Miyajima, M.; Takahashi, T.; Konno, S.; Hamada, T.; Kubota, S.; Shibamura, H.; Doke, T. Average energy expended per ion pair in liquid argon. Phys. Rev. A 1974, 9, 1438–1443. [Google Scholar] [CrossRef]
  184. Tanaka, M.; Doke, T.; Hitachi, A.; Kato, T.; Kikuchi, J.; Masuda, K.; Murakami, T.; Nishikido, F.; Okada, H.; Ozaki, K.; et al. LET dependence of scintillation yields in liquid xenon. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2001, 457, 454–463. [Google Scholar] [CrossRef]
  185. Thomas, J.; Imel, D.A. Recombination of electron-ion pairs in liquid argon and liquid xenon. Phys. Rev. A 1987, 36, 614–616. [Google Scholar] [CrossRef]
  186. Thomas, J.; Imel, D.A.; Biller, S. Statistics of charge collection in liquid argon and liquid xenon. Phys. Rev. A 1988, 38, 5793–5800. [Google Scholar] [CrossRef] [PubMed]
  187. Obodovskiy, I. Saturation curves and energy resolution of LRG ionization spectrometers. In Proceedings of the IEEE International Conference on Dielectric Liquids, ICDL, Coimbra, Portugal, 26 June–1 July 2005; pp. 321–324. [Google Scholar] [CrossRef]
  188. Amoruso, S.; Antonello, M.; Aprili, P.; Arneodo, F.; Badertscher, A.; Baiboussinov, B.; Baldo Ceolin, M.; Battistoni, G.; Bekman, B.; Benetti, P.; et al. Study of electron recombination in liquid argon with the ICARUS TPC. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2004, 523, 275–286. [Google Scholar] [CrossRef]
  189. Snider, E.; Petrillo, G. LArSoft: Toolkit for simulation, reconstruction and analysis of liquid argon TPC neutrino detectors. J. Phys. Conf. Ser. 2017, 898, 042057. [Google Scholar] [CrossRef]
  190. Mozumder, A. Free-ion yield in liquid argon at low-LET. Chem. Phys. Lett. 1995, 238, 143–148. [Google Scholar] [CrossRef]
  191. Aprile, E.; Ku, W.H.-M.; Park, J.; Schwartz, H. Energy resolution studies of liquid argon ionization detectors. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 1987, 261, 519–526. [Google Scholar] [CrossRef]
  192. Kozlova, E.; Mueller, J. NEST Liquid Argon Mean Yields Note; NEST Collaboration Website: 2020 UC Davis. Available online: https://docs.google.com/document/d/1vLg8vvY5bcdl4Ah4fzyE182DGWt0Wr7_FJ12_B10ujU/edit?usp=sharing (accessed on 18 March 2021).
  193. Berger, M.; Coursey, J.; Zucker, M.; Chang, J. ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions; National Institute of Standards and Technology: Gaithersburg, MD, USA, 2005. [Google Scholar]
  194. Acciarri, R.; Adams, C.; Asaadi, J.; Baller, B.; Bolton, T.; Bromberg, C.; Cavanna, F.; Church, E.; Edmunds, D.; Ereditato, A.; et al. Demonstration of MeV-scale physics in liquid argon time projection chambers using ArgoNeuT. Phys. Rev. D 2019, 99, 012002. [Google Scholar] [CrossRef] [Green Version]
  195. Agnes, P.; Albuquerque, I.; Alexander, T.; Alton, A.; Araujo, G.; Asner, D.; Ave, M.; Back, H.; Baldin, B.; Batignani, G.; et al. Low-Mass Dark Matter Search with the DarkSide-50 Experiment. Phys. Rev. Lett. 2018, 121, 081307. [Google Scholar] [CrossRef] [Green Version]
  196. Akimov, D.; Albert, J.B.; An, P.; Awe, C.; Barbeau, P.S.; Becker, B.; Belov, V.; Blackston, M.A.; Blokland, L.; Bolozdynya, A.; et al. COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon. arXiv 2020, arXiv:2006.12659. [Google Scholar] [CrossRef]
  197. Creus, W.; Allkofer, Y.; Amsler, C.; Ferella, A.; Rochet, J.; Scotto-Lavina, L.; Walter, M. Scintillation efficiency of liquid argon in low energy neutron-argon scattering. J. Instrum. 2015, 10, P08002. [Google Scholar] [CrossRef] [Green Version]
  198. Regenfus, C.; Allkofer, Y.; Amsler, C.; Creus, W.; Ferella, A.; Rochet, J.; Walter, M. Study of nuclear recoils in liquid argon with monoenergetic neutrons. J. Phys. Conf. Ser. 2012, 375, 012019. [Google Scholar] [CrossRef] [Green Version]
  199. Alexander, T.; Back, H.O.; Cao, H.; Cocco, A.G.; DeJongh, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; Kendziora, C.; Lippincott, W.H.; et al. Observation of the dependence on drift field of scintillation from nuclear recoils in liquid argon. Phys. Rev. D 2013, 88, 092006. [Google Scholar] [CrossRef] [Green Version]
  200. Cao, H.; Alexander, T.; Aprahamian, A.; Avetisyan, R.; Back, H.O.; Cocco, A.G.; DeJongh, F.; Fiorillo, G.; Galbiati, C.; Grandi, L.; et al. Measurement of scintillation and ionization yield and scintillation pulse shape from nuclear recoils in liquid argon. Phys. Rev. D 2015, 91, 092007. [Google Scholar] [CrossRef] [Green Version]
  201. Hitachi, A.; Mozumder, A. Properties for liquid argon scintillation for dark matter searches. arXiv 2019, arXiv:1903.05815. [Google Scholar]
  202. Agnes, P.; Albuquerque, I.; Alexander, T.; Alton, A.; Arisaka, K.; Asner, D.; Ave, M.; Back, H.; Baldin, B.; Biery, K.; et al. The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter. J. Instrum. 2017, 12, P12011. [Google Scholar] [CrossRef]
  203. Mei, D.M.; Yin, Z.B.; Stonehill, L.; Hime, A. A model of nuclear recoil scintillation efficiency in noble liquids. Astropart. Phys. 2008, 30, 12–17. [Google Scholar] [CrossRef] [Green Version]
  204. Broerman, B.; Boulay, M.; Cai, B.; Cranshaw, D.; Dering, K.; Florian, S.; Gagnon, R.; Giampa, P.; Gilmour, C.; Hearns, C.; et al. Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface. J. Instrum. 2017, 12, P04017. [Google Scholar] [CrossRef] [Green Version]
  205. Gehman, V.; Seibert, S.; Rielage, K.; Hime, A.; Sun, Y.; Mei, D.M.; Maassen, J.; Moore, D. Fluorescence efficiency and visible re-emission spectrum of tetraphenyl butadiene films at extreme ultraviolet wavelengths. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2011, 654, 116–121. [Google Scholar] [CrossRef] [Green Version]
  206. Tope, T.; Adamowski, M.; Carls, B.; Hahn, A.; Jaskierny, W.; Jostlein, H.; Kendziora, C.; Lockwitz, S.; Pahlka, B.; Plunkett, R.; et al. Extreme argon purity in a large, non-evacuated cryostat. AIP Conf. Proc. 2014, 1573, 1169–1175. [Google Scholar] [CrossRef]
Figure 1. Reconstruction of the 2.8224 keV 37 Ar peak in the PIXeY detector [59] compared to the Noble Element Simulation Technique (NEST). Real data are always hollow black circles, NEST Monte Carlo (MC) data are green squares. Gaussian fits are in red, skew Gaussian (better fit) in blue, with the fits to data in long dash and NEST in short dash (indistinguishable due to NEST’s fidelity). Number of events in data 7.4 × 10 4 , while 9.3 × 10 5 in the MC, after all cuts (i.e., all thresholds). (a) Original, non-linear S1-only E scale used for liquid xenon (LXe). Bins with non-zero counts begin very suddenly at the left in both NEST and data due to a cut-off created by triggering only on 3-fold PMT (Photo-Multiplier Tube) coincidence, and other threshold requirements. The results are highly skewed, driving the asymmetry within the combined-energy fit later. (b) S2-only, which is quite symmetric, so that Gaussian and skew-Gaussian fits overlap. (c) The combined-energy scale in common use now for LXe dark matter (DM) detectors. Gaussian fits in red are clearly poorer compared to skew fits, diverging from the histogram in the cases of NEST and data alike. (d) An optimized combination for energy, as done on PIXeY. Both NEST and data, and Gaussian and skew-Gaussian fits alike, have all become indistinguishable for this stage. The best-fit mean energy has shifted from 3.03 keV in (c) to 2.82 keV for (d). This improvement in precision is also reflected in the sum of the mean quanta from (a,b) matching (d), but not (c), which is too high. The skew parameter α decreases from 3 for S1 only (a) to 2 for the combined scale in (c) and 1 in (b,d).
Figure 1. Reconstruction of the 2.8224 keV 37 Ar peak in the PIXeY detector [59] compared to the Noble Element Simulation Technique (NEST). Real data are always hollow black circles, NEST Monte Carlo (MC) data are green squares. Gaussian fits are in red, skew Gaussian (better fit) in blue, with the fits to data in long dash and NEST in short dash (indistinguishable due to NEST’s fidelity). Number of events in data 7.4 × 10 4 , while 9.3 × 10 5 in the MC, after all cuts (i.e., all thresholds). (a) Original, non-linear S1-only E scale used for liquid xenon (LXe). Bins with non-zero counts begin very suddenly at the left in both NEST and data due to a cut-off created by triggering only on 3-fold PMT (Photo-Multiplier Tube) coincidence, and other threshold requirements. The results are highly skewed, driving the asymmetry within the combined-energy fit later. (b) S2-only, which is quite symmetric, so that Gaussian and skew-Gaussian fits overlap. (c) The combined-energy scale in common use now for LXe dark matter (DM) detectors. Gaussian fits in red are clearly poorer compared to skew fits, diverging from the histogram in the cases of NEST and data alike. (d) An optimized combination for energy, as done on PIXeY. Both NEST and data, and Gaussian and skew-Gaussian fits alike, have all become indistinguishable for this stage. The best-fit mean energy has shifted from 3.03 keV in (c) to 2.82 keV for (d). This improvement in precision is also reflected in the sum of the mean quanta from (a,b) matching (d), but not (c), which is too high. The skew parameter α decreases from 3 for S1 only (a) to 2 for the combined scale in (c) and 1 in (b,d).
Instruments 05 00013 g001
Figure 2. Review of E resolutions and means. (a) Resolution vs. E for LUX monoenergetic calibration plus background [52]. Only combined resolutions published (black), but S1 (red) and S2 (cyan) scales included from NEST, to show they are mutually comparable at O(10–1000) keV. The lowest-E point is optimized as done in PIXeY, so anomalously good (low). NEST combined scale blue (below S2 only in cyan except for 37 Ar) and optimized gold. w 1 in optimal scale varies from 0.26 to 1.0 from 2.8 to 662 keV, while w 2 falls from 1.45 to 1.00. (Lines are guides not fits.) (b) Data from neriX (Columbia’s small-scale calibration chamber, like PIXeY) as black points vs. measured recoil energies from Compton scatters [65] compared to NEST in blue vs. true energy known from MC, showing consistent deviation for both in reconstructed energies for a combined but non-optimized scale due to threshold bias (weights as used for NEST in gold in (a) correcting for this not applied purposely in blue in (b) to show this effect).
Figure 2. Review of E resolutions and means. (a) Resolution vs. E for LUX monoenergetic calibration plus background [52]. Only combined resolutions published (black), but S1 (red) and S2 (cyan) scales included from NEST, to show they are mutually comparable at O(10–1000) keV. The lowest-E point is optimized as done in PIXeY, so anomalously good (low). NEST combined scale blue (below S2 only in cyan except for 37 Ar) and optimized gold. w 1 in optimal scale varies from 0.26 to 1.0 from 2.8 to 662 keV, while w 2 falls from 1.45 to 1.00. (Lines are guides not fits.) (b) Data from neriX (Columbia’s small-scale calibration chamber, like PIXeY) as black points vs. measured recoil energies from Compton scatters [65] compared to NEST in blue vs. true energy known from MC, showing consistent deviation for both in reconstructed energies for a combined but non-optimized scale due to threshold bias (weights as used for NEST in gold in (a) correcting for this not applied purposely in blue in (b) to show this effect).
Instruments 05 00013 g002
Figure 3. (a) The 2.5 MeV resolution in LXe according to NEST vs. g 1 and fields. For one reasonable field, 500 V/cm, systematic uncertainty due to model choice shown: dashed cyan is the NEST electron recoil (ER) model based on photoabsorption gamma data, solid is the ER model from gamma Compton scattering and betas, and dotted line is a different beta model, based on [24]. The differences are most significant at low g 1 , where the exact L y value is more important. It is a key question for nEXO whether yields are more beta- or gamma-like. (b) The middle-of-the-road default beta model was selected, and g 1 and field frozen at 0.1 and 500 V/cm, and the resolution as a function of the Fano factor assumed is presented, for different levels of noise in the S1 (primary scintillation) signal. As on the left, combined E used, except for the dashed line (S1) and dotted (S2 or Q) for comparison to more detectors, as close to the max (worst) possible.
Figure 3. (a) The 2.5 MeV resolution in LXe according to NEST vs. g 1 and fields. For one reasonable field, 500 V/cm, systematic uncertainty due to model choice shown: dashed cyan is the NEST electron recoil (ER) model based on photoabsorption gamma data, solid is the ER model from gamma Compton scattering and betas, and dotted line is a different beta model, based on [24]. The differences are most significant at low g 1 , where the exact L y value is more important. It is a key question for nEXO whether yields are more beta- or gamma-like. (b) The middle-of-the-road default beta model was selected, and g 1 and field frozen at 0.1 and 500 V/cm, and the resolution as a function of the Fano factor assumed is presented, for different levels of noise in the S1 (primary scintillation) signal. As on the left, combined E used, except for the dashed line (S1) and dotted (S2 or Q) for comparison to more detectors, as close to the max (worst) possible.
Instruments 05 00013 g003
Figure 4. (a) Histogram of 10 6 NEST uniform-E-spectrum events (0–20 keV true) binned using MC truth energies (red), reconstructed energy from the combined scale (blue), and re-weighted optimal reconstruction (gold). Gold outperforms blue even visually, correcting underestimation of efficiency sub-keV, plus overestimation near 1.5 keV (see the text for quantitative goodness of fit comparisons). Tritiated methane (CH 3 T) is the black points, for validation against actual data. Its efficiency curve is markedly similar despite a non-flat spectrum. As it is continuous, the E is still only reconstructed, not known to infinite precision as in MCs, although an attempt to empirically account for smearing was made by LUX [76,79]. The solid black line is the Gompertz fit, superior to a more traditional e r f , dashed, while the inset zooms on low energies for clarity, with a linear x-axis and log y now. (b) The true Es repeated in gray, but now compared to S1 (red) and S2-only (cyan) scales (Equations (2) and (3)), with the former possessing unnatural peaks at left and right, and the latter grossly underestimating efficiency at keV scales. The default public beta model (NEST v2.2.0) is used here but comparable results occur with gamma rays.
Figure 4. (a) Histogram of 10 6 NEST uniform-E-spectrum events (0–20 keV true) binned using MC truth energies (red), reconstructed energy from the combined scale (blue), and re-weighted optimal reconstruction (gold). Gold outperforms blue even visually, correcting underestimation of efficiency sub-keV, plus overestimation near 1.5 keV (see the text for quantitative goodness of fit comparisons). Tritiated methane (CH 3 T) is the black points, for validation against actual data. Its efficiency curve is markedly similar despite a non-flat spectrum. As it is continuous, the E is still only reconstructed, not known to infinite precision as in MCs, although an attempt to empirically account for smearing was made by LUX [76,79]. The solid black line is the Gompertz fit, superior to a more traditional e r f , dashed, while the inset zooms on low energies for clarity, with a linear x-axis and log y now. (b) The true Es repeated in gray, but now compared to S1 (red) and S2-only (cyan) scales (Equations (2) and (3)), with the former possessing unnatural peaks at left and right, and the latter grossly underestimating efficiency at keV scales. The default public beta model (NEST v2.2.0) is used here but comparable results occur with gamma rays.
Instruments 05 00013 g004
Figure 5. All available world data on LXe NR at time of writing summarized in one place, with N p h and N e combined into N q . Where the Es did not match up (sometimes even within the same data set), a simple power law was used to spline (only interpolate not extrapolate) the numbers of photons first to add them to electrons. E-field does not cause measurable differences. (a) Only directly measured yields using angular measurements to determine E [27,30,121,122]. These are handled as more “trustworthy” in the community due to being quasi-monoenergetic analyses, and thus given the most weight in the fit even if there were fewer points. One simple power law appears to describe the data points across over three orders of magnitude in E, depicted as the black line, dashed or solid, within every plot pane. For (a), an uncertainty band was included (2 σ for clear visualization in green, not 1 σ ). (b) Dahl’s thesis data from the Xed detector taken from broad-spectrum shape spline fits ( 252 Cf) [36]. * Corr(ected) on the y-axis refers to correcting the data in our global meta-re-analysis for effects often not known at the time of data-taking, such as the 2-photoelectron (phe) effect, or the extraction efficiency being much less than 100% than the data-takers had originally estimated [16,123,124]. The former can lower the L y measurements, depending on the analysis technique, while the latter raises Q y data points typically. The x-axis was corrected in the sense of energy estimates updated with a more modern combined-E scale whenever possible. (c) More (indirect) measurements from continuous source bands, from XENON, ZEPLIN, and PandaX [35,56,68,80,125,126,127,128,129,130]. Errors in data used whenever reported. (d,e) A review of models [27,48,131,132,133,134,135]. (f) Low-E zoom of models, with data included, as larger-size points.
Figure 5. All available world data on LXe NR at time of writing summarized in one place, with N p h and N e combined into N q . Where the Es did not match up (sometimes even within the same data set), a simple power law was used to spline (only interpolate not extrapolate) the numbers of photons first to add them to electrons. E-field does not cause measurable differences. (a) Only directly measured yields using angular measurements to determine E [27,30,121,122]. These are handled as more “trustworthy” in the community due to being quasi-monoenergetic analyses, and thus given the most weight in the fit even if there were fewer points. One simple power law appears to describe the data points across over three orders of magnitude in E, depicted as the black line, dashed or solid, within every plot pane. For (a), an uncertainty band was included (2 σ for clear visualization in green, not 1 σ ). (b) Dahl’s thesis data from the Xed detector taken from broad-spectrum shape spline fits ( 252 Cf) [36]. * Corr(ected) on the y-axis refers to correcting the data in our global meta-re-analysis for effects often not known at the time of data-taking, such as the 2-photoelectron (phe) effect, or the extraction efficiency being much less than 100% than the data-takers had originally estimated [16,123,124]. The former can lower the L y measurements, depending on the analysis technique, while the latter raises Q y data points typically. The x-axis was corrected in the sense of energy estimates updated with a more modern combined-E scale whenever possible. (c) More (indirect) measurements from continuous source bands, from XENON, ZEPLIN, and PandaX [35,56,68,80,125,126,127,128,129,130]. Errors in data used whenever reported. (d,e) A review of models [27,48,131,132,133,134,135]. (f) Low-E zoom of models, with data included, as larger-size points.
Instruments 05 00013 g005
Figure 6. (a) Combined (blue) and optimal (yellow) scales for a 50 GeV standard weakly interacting massive particle (WIMP) spectrum, the MC truth for which is black. Above 2 keV, bins are omitted in log fashion for clarity. LUX detector parameters (i.e., Run03, first WIMP search) used as earlier for similar ER plot, again for illustrative purposes (∼180 V/cm). Yellow corrects for sub-keV efficiency underestimation, and an overestimation at several keV, comparing yellow to black and blue to black (these effects can change from detector to detector, with signal shape). While a distinct functional form vis-à-vis ER, w 2 is again S-shaped. Better results may be possible with lower w 1 , kept fixed at 1.0 again here for simplicity. In actual data, with ER and NR mixed, backgrounds with potential signals, it is impossible to know a priori if applying keV n r or e e is more appropriate by event. (b) True spectrum is repeated, but now compared with S1/S2 in red/cyan. Power laws in the legend are crude, detector-specific approximations, but can be converted using S 1 c = g 1 N p h , S 2 c = g 2 N e ( g 1 = 0.117 , g 2 = 12.1 ). For why both powers are ∼1, please see Equation (6).
Figure 6. (a) Combined (blue) and optimal (yellow) scales for a 50 GeV standard weakly interacting massive particle (WIMP) spectrum, the MC truth for which is black. Above 2 keV, bins are omitted in log fashion for clarity. LUX detector parameters (i.e., Run03, first WIMP search) used as earlier for similar ER plot, again for illustrative purposes (∼180 V/cm). Yellow corrects for sub-keV efficiency underestimation, and an overestimation at several keV, comparing yellow to black and blue to black (these effects can change from detector to detector, with signal shape). While a distinct functional form vis-à-vis ER, w 2 is again S-shaped. Better results may be possible with lower w 1 , kept fixed at 1.0 again here for simplicity. In actual data, with ER and NR mixed, backgrounds with potential signals, it is impossible to know a priori if applying keV n r or e e is more appropriate by event. (b) True spectrum is repeated, but now compared with S1/S2 in red/cyan. Power laws in the legend are crude, detector-specific approximations, but can be converted using S 1 c = g 1 N p h , S 2 c = g 2 N e ( g 1 = 0.117 , g 2 = 12.1 ). For why both powers are ∼1, please see Equation (6).
Instruments 05 00013 g006
Figure 7. Reconstruction of the 41.5 keV 83 m Kr peak in DarkSide (DS) [23] compared to NEST, with data as black dots, NEST gray squares. For clarity, no fits overlaid, although most data are ∼Gaussian. (a) S1-only E scale most common for LAr-based DM detectors [22]. Our work/conclusions for such a scale should apply not only to time projection chambers (TPCs) where ionization e s are drifted but also to 0 V/cm 1-phase detectors, where these electrons fail to recombine to add to the S1 in LAr for both ER and NR [158,166,167] just as in LXe [32], with the L y having the same shape vs. E as for non-zero fields as field goes to 0 in TPCs (see Doke et al. as well as Wang and Mei for possible reasons [78,141,168,169]). (b) S2-only, with the slight right-hand asymmetry nearly reproduced by NEST [21]. (c) Combined-E scale, now standard at least in DS. Optimization as done in LXe could be possible, but not shown. Resolution is poorer than in (a) instead of better due to poor S2 resolution in (b) and that S2 is being combined with S1, on top of 39 Ar. This is explained in the text, as likely due to lack of XY correction creating noise not correlated with S1. For Es below 1 MeV, like here, this is not likely due to delta rays not being simulated by NEST by itself, as no S2 noise (and little in S1) is needed in the next plot (d) and S1 is not as wide as S2 in (a), while delta rays would affect both. Combined E, canceling them, should still be better in general in Ar as in Xe. (d) Resolution vs. E for monoenergetic calibrations/backgrounds studied on DS [23]. Only one set of resolutions covering a broad E range was found (black) to compare to combined E from NEST (blue).
Figure 7. Reconstruction of the 41.5 keV 83 m Kr peak in DarkSide (DS) [23] compared to NEST, with data as black dots, NEST gray squares. For clarity, no fits overlaid, although most data are ∼Gaussian. (a) S1-only E scale most common for LAr-based DM detectors [22]. Our work/conclusions for such a scale should apply not only to time projection chambers (TPCs) where ionization e s are drifted but also to 0 V/cm 1-phase detectors, where these electrons fail to recombine to add to the S1 in LAr for both ER and NR [158,166,167] just as in LXe [32], with the L y having the same shape vs. E as for non-zero fields as field goes to 0 in TPCs (see Doke et al. as well as Wang and Mei for possible reasons [78,141,168,169]). (b) S2-only, with the slight right-hand asymmetry nearly reproduced by NEST [21]. (c) Combined-E scale, now standard at least in DS. Optimization as done in LXe could be possible, but not shown. Resolution is poorer than in (a) instead of better due to poor S2 resolution in (b) and that S2 is being combined with S1, on top of 39 Ar. This is explained in the text, as likely due to lack of XY correction creating noise not correlated with S1. For Es below 1 MeV, like here, this is not likely due to delta rays not being simulated by NEST by itself, as no S2 noise (and little in S1) is needed in the next plot (d) and S1 is not as wide as S2 in (a), while delta rays would affect both. Combined E, canceling them, should still be better in general in Ar as in Xe. (d) Resolution vs. E for monoenergetic calibrations/backgrounds studied on DS [23]. Only one set of resolutions covering a broad E range was found (black) to compare to combined E from NEST (blue).
Instruments 05 00013 g007
Figure 8. (a) Lack of delta rays in Geant4 altering median Q at 1 MeV in a large 500 V/cm LAr volume, more so as the threshold in track length set by the user for creation of secondary e s increases past the value from Mozumder [190]. The default threshold is typically too high by >10 times, in length and/or E, in neutrino simulations [189]. (b) Demonstration of S versus Q anti-correlation from our reanalysis of Doke et al. 1988 and 2002 [78,169], confirmed by the recent Liquid Argon In A Test beam (LArIAT) study [180]. A 1 MeV ER at different E-fields, as opposed to many Es at one E-field (as done for a contemporary “Doke plot”). (c) Noiseless charge-only resolution vs. fixed electron E using Geant4, with G4 secondary production range cuts of 1 m (blue) and 0.7 mm (black, in LArSoft), compared to data points at isolated Es on recombination fluctuations with delta rays from [186] (red) and [191] (green, no measurement uncertainty provided).
Figure 8. (a) Lack of delta rays in Geant4 altering median Q at 1 MeV in a large 500 V/cm LAr volume, more so as the threshold in track length set by the user for creation of secondary e s increases past the value from Mozumder [190]. The default threshold is typically too high by >10 times, in length and/or E, in neutrino simulations [189]. (b) Demonstration of S versus Q anti-correlation from our reanalysis of Doke et al. 1988 and 2002 [78,169], confirmed by the recent Liquid Argon In A Test beam (LArIAT) study [180]. A 1 MeV ER at different E-fields, as opposed to many Es at one E-field (as done for a contemporary “Doke plot”). (c) Noiseless charge-only resolution vs. fixed electron E using Geant4, with G4 secondary production range cuts of 1 m (blue) and 0.7 mm (black, in LArSoft), compared to data points at isolated Es on recombination fluctuations with delta rays from [186] (red) and [191] (green, no measurement uncertainty provided).
Instruments 05 00013 g008
Figure 9. R vs. d E / d x in ICARUS data (stopping muons, protons) [188] at fields 500, 350, 200 V/cm. Data in black/white, as white circle, black circle, and black star, while results of a Geant4 MC making use of the NEST 2013 LAr ER model are colored red, yellow, and blue respectively, with decreasing field; protons, muons, electrons, and their respective antiparticles, while varying in R at the 5% level, are sufficiently consistent to combine. The x-axis here is linear energy transfer (LET), or, d E / d x divided by density (NEST points extracted by individual secondary track from 1 GeV total-E simulations).
Figure 9. R vs. d E / d x in ICARUS data (stopping muons, protons) [188] at fields 500, 350, 200 V/cm. Data in black/white, as white circle, black circle, and black star, while results of a Geant4 MC making use of the NEST 2013 LAr ER model are colored red, yellow, and blue respectively, with decreasing field; protons, muons, electrons, and their respective antiparticles, while varying in R at the 5% level, are sufficiently consistent to combine. The x-axis here is linear energy transfer (LET), or, d E / d x divided by density (NEST points extracted by individual secondary track from 1 GeV total-E simulations).
Instruments 05 00013 g009
Figure 10. (a) The (E-field-independent) total number of quanta N q per keV for NR in liquid argon: L y + Q y , or ( N p h + N e ) / E . The best-fit power law, used in the current NEST NR model for LAr, is ( 11.10 ± 1.10 ) E 0.087 ± 0.025 , surprisingly similar to LXe, with 1 σ /2 σ error bands in green/yellow. Kimura data [167] are given as a fit to the data in the original paper; SCENE and ARIS points are taken from [175,200]. (b) A review of models, collected from [132,143,201], covering Lindhard/Lindhard-like approaches. Solid lines assume 45 photons/keV for the (0 V/cm) L y of ER in LAr, with upper and lower dashes covering 50 and 40, respectively, to span the uncertainty in light, before addition with Q y . (c) As in (a,b), NEST is repeated here with two additional model comparisons, from PARIS (used by DS [202]) and [203].
Figure 10. (a) The (E-field-independent) total number of quanta N q per keV for NR in liquid argon: L y + Q y , or ( N p h + N e ) / E . The best-fit power law, used in the current NEST NR model for LAr, is ( 11.10 ± 1.10 ) E 0.087 ± 0.025 , surprisingly similar to LXe, with 1 σ /2 σ error bands in green/yellow. Kimura data [167] are given as a fit to the data in the original paper; SCENE and ARIS points are taken from [175,200]. (b) A review of models, collected from [132,143,201], covering Lindhard/Lindhard-like approaches. Solid lines assume 45 photons/keV for the (0 V/cm) L y of ER in LAr, with upper and lower dashes covering 50 and 40, respectively, to span the uncertainty in light, before addition with Q y . (c) As in (a,b), NEST is repeated here with two additional model comparisons, from PARIS (used by DS [202]) and [203].
Instruments 05 00013 g010
Figure 11. (a) S1 peak and (b) S2 peak for 16.9 keV NR in LAr from Cao et al. [200]. Data are in black with errors, with original MC in red (fit borders for it as vertical blue lines) and NEST overlaid in gray over original paper plots: defaults solid, while altered to match data in dash. Large noise levels needed in NEST are comparable to those assumed by SCENE ( R 1 and R 2 in legends imply S1 30%, S2 25%).
Figure 11. (a) S1 peak and (b) S2 peak for 16.9 keV NR in LAr from Cao et al. [200]. Data are in black with errors, with original MC in red (fit borders for it as vertical blue lines) and NEST overlaid in gray over original paper plots: defaults solid, while altered to match data in dash. Large noise levels needed in NEST are comparable to those assumed by SCENE ( R 1 and R 2 in legends imply S1 30%, S2 25%).
Instruments 05 00013 g011
Table 1. Survey of experimentally achieved energy resolutions at Q β β or very close to it (for instance, 2.6 MeV calibration). Entries marked with * are exceptions: extrapolations from power-law fits to much lower energies. Error bars are included whenever they were reported for the analyses. EXO made both hardware upgrades (Phase I, II) as well as many software enhancements.
Table 1. Survey of experimentally achieved energy resolutions at Q β β or very close to it (for instance, 2.6 MeV calibration). Entries marked with * are exceptions: extrapolations from power-law fits to much lower energies. Error bars are included whenever they were reported for the analyses. EXO made both hardware upgrades (Phase I, II) as well as many software enhancements.
ExperimentResolution [%] Gaussian 100*1 σ /MeanUncertainty
XENON10 [40]0.89 *
XENON100 [84]1.21 *
XENON1T [41]0.800.02
EXO-200 [85] single-scatter only4.5 for Q
EXO-200 [86] i b i d . 1.96410.0039
EXO-200 [87]1.84 (6.0–7.9 S1, 3.5 Q)0.03
EXO-200 [82]1.67
EXO-200 [86,88,89]1.5820 or 1.6(0)0.0044
EXO-200 [13,90,91,92,93]1.530.06
EXO-200 [10,94]1.38 then 1.23 then 1.150.02 (last)
EXO-200 [70]0.94(1)–1.38(2) comb and 3.44(6)–4.08(4) for Q
KamLAND-ZEN [95,96]4.0–4.3 (GXe dissolved in liquid scintillator)
KamLAND-ZEN [97,98,99,100]4.2∼0.2
KamLAND-ZEN [101]4.66
Table 2. Best (lowest) possible resolution of a 1 MeV electron recoil at 0.5 kV/cm as a function of the S1 photon detection efficiency g 1 and wire noise (in semi-log steps). Each entry is averaged over 10 4 simulations in stand-alone NEST, with the effect of delta rays approximated analytically (based on G4). All photons and electrons are included from the interaction, which is thus being treated as a single site.
Table 2. Best (lowest) possible resolution of a 1 MeV electron recoil at 0.5 kV/cm as a function of the S1 photon detection efficiency g 1 and wire noise (in semi-log steps). Each entry is averaged over 10 4 simulations in stand-alone NEST, with the effect of delta rays approximated analytically (based on G4). All photons and electrons are included from the interaction, which is thus being treated as a single site.
g 1 [ % ] 0% Q noise1%2%5%10%20%50%100%
0.0010.461.102.054.9910.020.146.062.5
0.0020.461.102.054.9910.020.146.062.5
0.0050.461.102.054.9910.020.146.054.6
0.010.461.102.054.9910.020.140.546.6
0.020.461.102.054.9910.020.134.142.4
0.050.461.102.054.9910.017.828.931.5
0.10.461.102.054.9910.014.522.122.1
0.20.461.102.054.998.7812.715.615.6
0.50.461.102.054.997.1210.010.010.0
10.461.102.054.216.347.087.087.08
20.461.102.053.554.994.994.994.99
50.461.101.793.083.143.143.143.14
100.461.101.472.202.202.202.202.20
200.460.871.281.531.531.531.531.53
500.390.670.910.910.910.910.910.91
1000.210.570.570.570.570.570.570.57
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Szydagis, M.; Block, G.A.; Farquhar, C.; Flesher, A.J.; Kozlova, E.S.; Levy, C.; Mangus, E.A.; Mooney, M.; Mueller, J.; Rischbieter, G.R.C.; et al. A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST. Instruments 2021, 5, 13. https://doi.org/10.3390/instruments5010013

AMA Style

Szydagis M, Block GA, Farquhar C, Flesher AJ, Kozlova ES, Levy C, Mangus EA, Mooney M, Mueller J, Rischbieter GRC, et al. A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST. Instruments. 2021; 5(1):13. https://doi.org/10.3390/instruments5010013

Chicago/Turabian Style

Szydagis, Matthew, Grant A. Block, Collin Farquhar, Alexander J. Flesher, Ekaterina S. Kozlova, Cecilia Levy, Emily A. Mangus, Michael Mooney, Justin Mueller, Gregory R. C. Rischbieter, and et al. 2021. "A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST" Instruments 5, no. 1: 13. https://doi.org/10.3390/instruments5010013

APA Style

Szydagis, M., Block, G. A., Farquhar, C., Flesher, A. J., Kozlova, E. S., Levy, C., Mangus, E. A., Mooney, M., Mueller, J., Rischbieter, G. R. C., & Schwartz, A. K. (2021). A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST. Instruments, 5(1), 13. https://doi.org/10.3390/instruments5010013

Article Metrics

Back to TopTop