Abstract

Corrosion of Post-Tension Tendons Associated with Segregated Grout †

Department of Civil and Environmental Engineering, Florida International University, Miami, FL 33174, USA
*
Author to whom correspondence should be addressed.
Presented at the First Corrosion and Materials Degradation Web Conference, 17–19 May 2021; Available online: https://cmdwc2021.sciforum.net/.
Mater. Proc. 2021, 6(1), 29; https://doi.org/10.3390/CMDWC2021-10036
Published: 13 May 2021
(This article belongs to the Proceedings of The 1st Corrosion and Materials Degradation Web Conference)

Abstract

:
Post-tensioned (PT) construction incorporating bonded tendons with cementitious grouts has been used for highway bridges. The tendon duct and the encapsulating grout materials provide barrier corrosion protection for the embedded high-strength steel strand. Although generally used in good engineering practice, cases of PT tendon corrosion have been documented relating to inadequate detailing for joints, development of grout bleed water, and, more recently in the past several years, segregation of thixotropic grouts. In the latter case, cases of thixotropic grouts (which have been developed to mitigate grout bleeding), developed physically and chemically deficient grout, have been characterized to have high moisture content and elevated sulfate ion concentrations. The early presence of elevated sulfate ion concentrations in the deficient grout was attributed to hindering stable steel passivation. Case studies of PT corrosion associated with grouts with elevated sulfate concentrations are presented followed by a review of electrochemical techniques and measurements used to identify the role of sulfates in steel corrosion in alkaline solutions such as polarization techniques, electrochemical impedance spectroscopy, and electrochemical noise.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/CMDWC2021-10036/s1.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Permeh, S.; Lau, K. Corrosion of Post-Tension Tendons Associated with Segregated Grout. Mater. Proc. 2021, 6, 29. https://doi.org/10.3390/CMDWC2021-10036

AMA Style

Permeh S, Lau K. Corrosion of Post-Tension Tendons Associated with Segregated Grout. Materials Proceedings. 2021; 6(1):29. https://doi.org/10.3390/CMDWC2021-10036

Chicago/Turabian Style

Permeh, Samanbar, and Kingsley Lau. 2021. "Corrosion of Post-Tension Tendons Associated with Segregated Grout" Materials Proceedings 6, no. 1: 29. https://doi.org/10.3390/CMDWC2021-10036

APA Style

Permeh, S., & Lau, K. (2021). Corrosion of Post-Tension Tendons Associated with Segregated Grout. Materials Proceedings, 6(1), 29. https://doi.org/10.3390/CMDWC2021-10036

Article Metrics

Back to TopTop