1. Introduction
Archaeogeophysics is a fundamental discipline for exploring and documenting cultural heritage. Geophysical methods are inherently non-destructive, and this feature makes them an essential support tool for archaeologists to provide detailed geometric reconstructions of the buried structures, especially when there is no possibility of direct investigation, and to identify the areas of greater archaeological interest [
1]. In this work, we present the results of geophysical surveys performed at Ugento (Lecce, Italy) to locate the ancient walls (
Figure 1a).
The ancient walls of Ugento date back to the period of maximum extension of the ancient city center, around the middle of the 4th century B.C. [
2]. It was built in a historical moment of great instability and conflict between the Messapians and Tarentines. Subsequently, between the second half of the 4th and 3rd centuries BC, they reinforced and defended the center even during the Second Punic War, when the inhabitants of Uzentum joined Hannibal in the battle against Rome.
The walls enclosed the low hill, on which the modern village of Ugento extends, and part of the flat areas located on its slopes, accounting for a total area of 145 hectares. Today, only a few sectors of the imposing fortifications, 4900 m long in total, are visible. The walls appeared in all their grandeur with a thickness of between 6 and 8 m and originally must have been approximately 6 m high (
Figure 1b,c). They consisted of two external curtain walls made of calcarenite blocks, which contained a filling of stones and soil. Along the route of the city walls and near the gates, there were quadrangular towers, which contributed to making it even more powerful.
Geophysical campaigns carried out previously on Messapian sites [
3,
4] have shown excellent results in identifying buried structures [
3] and reconstructing a stretch of the Messapian city walls and nearby necropolis in the St. Antonio area of Ugento [
4].
In the Cupa area, in the immediate western outskirts of the town, a section of the external face of the walls is visible and partially incorporated into the modern drywall (
Figure 1b). Here, a section of the internal curtain of the walls, measuring 16 m long, was brought to light in 2006. Such elements guided the hypothesis of the route of the walls. In this study, geophysical surveys were designed according to these archaeological aspects highlighted on the site, with two geophysical campaigns performed employing two methods: the frequency domain electromagnetometry (EM) in the first geophysical campaign and the ground-penetrating radar (GPR) in the second one. Several geophysical methods can be used in archaeological investigations. The GPR has been applied for 25 years in archaeological prospections to map shallow subsurface targets [
5]. For logistical reasons, the portion of the surface to be investigated was divided into different areas: 1, 2, and 3 and A, B, and C for the EM method (
Figure 2a) and areas D, E, and F for the GPR method (
Figure 2b). Their positions and extensions were defined by the conditions of the soil surface under examination and by the expected results compared to the evidence already known, both in trace and following archaeological tests conducted in the past. The soil surface between Area A and Area 2 was uneven due to the presence of shrubs; here, data were acquired along non-equally spaced and non-parallel profiles (P1, P2, P3, and P4).
Some preliminary EM results relating to this work were presented at the MetroArchaeo conference in 2023 [
6].
Starting with the results of geophysical prospecting, archaeological excavation campaigns were carried out in an area to find the presence of the structures identified by the geophysical investigations.
2. Materials and Methods
After a preliminary evaluation of the characteristics and conditions of the areas to be investigated and the extent of the archaeological structures to be identified, we carried out the first geophysical campaign through the application of the electromagnetic method in the frequency domain (FDEM). Electromagnetic prospecting techniques have been used for archaeological purposes since the late 1960s [
7,
8] and are able to identify a variety of archaeological features [
9,
10,
11,
12]. This method is mainly used for preliminary surveys of large areas and is one of the fastest geophysical methods. A second geophysical campaign was performed over a smaller area, resulting in high archaeological interest from the EM survey results (
Figure 2).
The ability of low-frequency EM instruments to identify archaeological structures is determined by physical issues such as sensor height, coil geometry, and the physical properties of the soil [
13]. In this work, we used the CMD mini-explorer probe, a multi-depth electromagnetic conductivity meter by GF Instruments (
Figure 2a). It consists of three sensors that allow information to be obtained in three depth ranges. Assuming an increasing distance between the transmitting coil and the receiving coil, the instrument can explore greater depths. The transmitting coil generates a time-varying primary magnetic field, which propagates above and below ground, generating alternating currents (eddy currents) within the soil and the buried objects. The eddy currents create a secondary magnetic field proportional to the rate of change of the primary magnetic field and are measured by receiving coils. The received secondary magnetic field consists of an imaginary part (the quadrature component), which is proportional to the ground conductivity, and a real part (the in-phase component), which is influenced by magnetic properties. In this work, we focus on the interpretation of the electrical conductivity distribution.
Setting the probe to HIGH mode allows measurements with a maximum depth range. In fact, the vertical orientation of magnetic dipoles allows the full depth range to be measured. The survey conducted in this setting allowed the exploration of the subsoil up to a depth of about z = 2 m from the ground level. The measurement was carried out in continuous mode by setting the measuring period to 0.2 s and maintaining a constant speed of movement that did not exceed 9 km/h. The out-of-phase and in-phase components were measured as average values obtained during one measuring period.
The acquired data were processed and interpreted to define the subsurface electromagnetic properties. Specifically, subsurface EM energy is influenced by electrical conductivity, dielectric permittivity, and magnetic susceptibility. Electrical conductivity and magnetic susceptibility govern the magnitude of the received EM signal and are therefore used to understand the electrical properties of subsurface materials [
1].
Data were acquired in grids with parallel profiles. The spacing between the profiles (∆x) was defined differently for every area: ∆x = 2 m in Areas A, B, and C; ∆x = 3 m in Area 1; and ∆x = 5 m in Areas 2 and 3. These choices were made due to the state of the soil surface.
The acquired data were exported to Res2DInv (v. 4.08) and Res3DInv (v. 3.14) [
14]. Considering the quadrature component, after removing the negative values of conductivity, the inversion routine was applied. We obtained the distribution of the electrical resistivity values at several depth ranges.
Ground-penetrating radar is one of the most utilized tools for archaeological prospection due to its high-resolution data and 3D visualization capabilities [
15,
16,
17]. It allows the collection of a large amount of information on large areas in the first few meters of the subsoil, which is related to the presence of buried bodies or structures of archaeological interest. GPR generates high-frequency impulsive waves (typically between 10 MHz and a few GHz), which are transmitted underground using a suitable transmitting antenna placed in contact with the ground surface. The electromagnetic signal propagates in the medium and is reflected when it encounters a medium with different electromagnetic parameters (discontinuity). The reflected wave that returns to the surface is recorded by a receiving antenna. The control unit amplifies the captured reflection and records it in digital format. By measuring the time interval taken by the pulse to arrive at the buried discontinuity, reflect, and return to the receiver, the position of the reflecting structure can be traced if the propagation velocity is known [
1]. The physical parameters that influence the propagation of electromagnetic waves are the electrical conductivity σ (s/m), the dielectric permittivity ε, and the magnetic permeability µ. The GPR method obtains good results when operating on resistive soils, allowing the identification of structures with different electromagnetic characteristics compared to the surrounding environment. In the presence of soils with high conductivity, the electromagnetic wave energy is absorbed by the material, causing a drastic signal attenuation and limiting the depth of investigation (i.e., layers of clay or humidity in the subsoil).
In this work, GPR measurements were performed with an IDS Ris Hi-mode system equipped with a dual-band antenna at a nominal central frequency of 200–600 MHz (
Figure 2b). A grid of 1 m parallelly spaced profiles was constructed in the three investigated areas (D, E, and F). The time windows were set at 75 ns (600 MHz antenna) and 150 ns (200 MHz antenna), and the B-scan was discretized using 512 samples. The processing of the GPR data consisted of zero timing, background removal, bandpass filtering, and Kirchoff migration. This processing was carried out through the GPRSlice software Version 7.0 [
18]. From the shape of the diffraction hyperbolas, we found an average electromagnetic wave velocity equal to 0.085 m/ns. Afterward, the Hilbert transform was applied to the processed data to obtain horizontal depth–time slices. Each slice was retrieved by averaging the data within a time window ∆t = 5 ns, which corresponds to a soil thickness of about 20 cm.
4. Discussion
The results of the geophysical surveys conducted in 2023 in the Cupa area on the immediate western outskirts of the town were used to identify the buried section of the ancient walls of Uzentum, which is the largest ancient center in Messapia. The investigations were also aimed at evaluating the state of conservation of the fortifications and, therefore, planning a targeted excavation campaign.
The archaeological excavations began in January 2024 and confirmed the geophysical results acquired the previous year, documenting a long stretch of the city wall that is preserved for a maximum length of 32 m and a maximum height of 1.60 m (
Figure 9a). In this sector, the fortifications are characterized by two curtains with large blocks of calcarenite arranged alternately, head and cutting, with an internal
emplèkton made up of earth and calcareous stone.
In particular, the internal curtain of the walls is obliterated by a large modern dry stone wall having the same orientation as the ancient walls; the external curtain of the walls (with a thickness of 1.5 m), including the corner, located in the north-western sector of the investigated area, corresponds exactly to the anomalies recorded by the electromagnetic instrumentation at depths reaching up to z = 1.50 m. The highlighting of this wall sector provided data about the construction solutions adopted at a particularly vulnerable point of the fortifications. At the corner, an oblique structure 5.5 m long, made with blocks placed head-on, could be attributable to an infill structure made in a second construction phase of the city walls, when probably the timely repair of damage to the walls was necessary (
Figure 9b,c). Before the excavation, precisely at this point, electromagnetic investigations had recorded numerous anomalies initially linked to the possible presence of a tower or other reinforcement structures. The stratigraphic investigations made it possible to understand more clearly the nature of these anomalies, which can actually refer to the blocks placed in secondary positions (
Figure 9b,c), because they collapsed or were removed during the demolition phase of the walls in the final decades of the 3rd century B.C. Numerous blocks resulting from the demolition phase of the walls of Ugento were also documented immediately outside the external curtain of the wall.