Next Article in Journal
Advancements in Thermal Insulation through Ceramic Micro-Nanofiber Materials
Next Article in Special Issue
On-Site Sensitive Colorimetry for Free Cyanide by Using Ion-Pair Solid-Phase Extraction with Sedimentable Dispersed Particulates and Mobile Photography Box
Previous Article in Journal
Innovative Solid-Phase Extraction Strategies for Improving the Advanced Chromatographic Determination of Drugs in Challenging Biological Samples
Previous Article in Special Issue
Rapid and Visual Detection of Volatile Amines Based on Their Gas–Solid Reaction with Tetrachloro-p-Benzoquinone
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Highly Sensitive and Group-Specific Enzyme-Linked Immunosorbent Assay (ELISA) for the Detection of AFB1 in Agriculture and Aquiculture Products

1
The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Renai Road 199, Suzhou 215123, China
2
School of Biology & Basic Medical Science, Soochow University, Renai Road 199, Suzhou 215123, China
3
Suzhou Agricultural Products Safety and Quality Inspection Center, Wuzhong Road 1399, Suzhou 215000, China
*
Authors to whom correspondence should be addressed.
Molecules 2024, 29(10), 2280; https://doi.org/10.3390/molecules29102280
Submission received: 6 April 2024 / Revised: 29 April 2024 / Accepted: 4 May 2024 / Published: 12 May 2024
(This article belongs to the Special Issue Advances in Green Analytical Chemistry)

Abstract

:
Aflatoxins (AFs) including AFB1, AFB2, AFG1 and AFG2 are widely found in agriculture products, and AFB1 is considered one of the most toxic and harmful mycotoxins. Herein, a highly sensitive (at the pg mL−1 level) and group-specific enzyme-linked immunosorbent assay (ELISA) for the detection of AFB1 in agricultural and aquiculture products was developed. The AFB1 derivative containing a carboxylic group was synthesized and covalently linked to bovine serum albumin (BSA). The AFB1-BSA conjugate was used as an immunogen to immunize mice. A high-quality monoclonal antibody (mAb) against AFB1 was produced by hybridoma technology, and the mAb-based ELISA for AFB1 was established. IC50 and limit of detection (LOD) of the ELISA for AFB1 were 90 pg mL−1 and 18 pg mL−1, respectively. The cross-reactivities (CRs) of the assay with AFB2, AFG1, and AFG2 were 23.6%, 42.5%, and 1.9%, respectively, revealing some degree of group specificity. Corn flour, wheat flour, and crab roe samples spiked with different contents of AFB1 were subjected to ELISA procedures. The recoveries and relative standard deviation (RSD) of the ELISA for AFB1 in spiked samples were 78.3–116.6% and 1.49–13.21% (n = 3), respectively. Wheat flour samples spiked with the mixed AF (AFB1, AFB2, AFG1, AFG2) standard solution were measured by ELISA and LC-MS/MS simultaneously. It was demonstrated that the proposed ELISA can be used as a screening method for evaluation of AFs (AFB1, AFB2, AFG1, AFG2) in wheat flour samples.

1. Introduction

Aflatoxins (AFs), the highly toxic secondary metabolites produced by Aspergillus flavus and Aspergillus parasiticus fungi, are present in a wide range of food and feed commodities, and are assumed significant because of their deleterious effects on human beings, poultry, and livestock [1,2,3]. There are up to 18 types of AFs, but only 6 of them (AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2) are regulated for food control [4]. The first four are the major pollutants in agriculture products, while AFM1 and AFM2, which are mainly found in milk, are generated by some mammals such as cows after consuming feed contaminated with AFB1 or AFB2 [5]. Among the six AFs above, AFB1 is considered the most widely distributed, toxic, and harmful [6]. Various agriculture and food products such as corn, wheat, peanuts, soybeans, cooking oil, alcoholic beverages, and poultry feeds are susceptible to AFB1 contamination [7]. AFB1 has been classified as a human carcinogen (Group 1) by the International Agency for Research on Cancer (IARC) due to its carcinogenic, mutagenic, and teratogenic potential [8]. Because of the risk of the presence of AFs in foods, many countries have implemented corresponding regulations. The European Union has established that the maximum residue level (MRL) of total AFs (AFB1, AFB2, AFG1, and AFG2) in food should not exceed 10 μg kg−1. In addition, AFB1 has an individual MRL of 5 μg kg−1 in foods for human consumption and 0.1 μg kg−1 in products for infants [9]. In China, the MRL of AFB1 is also specified, including for peanut oil and corn oil (20 µg kg−1), wheat, barley, and their products (5 µg kg−1), corn and corn products (20 µg kg−1), and cooked nuts (5 µg kg−1), and is 0.5 µg kg−1 in infants [10]. Hence, reliable and sensitive analytical methods for trace AFB1 detection are of paramount importance.
The main analytical methods used for the detection of AFB1 in agriculture products are liquid chromatography–tandem mass spectrometry (LC-MS/MS) and high-performance liquid chromatography with fluorescence detection (HPLC-FLD) [11,12,13]. These chromatographic methods have high sensitivity, selectivity, and accuracy, but have limitations related to the requirement for qualified and skilled personnel, expensive equipment, time-consuming processes, and large sample volumes involved.
Immunoassays, particularly enzyme-linked immunosorbent assays (ELISAs), are sensitive and specific analytical methods based on the interaction between the antibody and antigen [14,15]. In addition, ELISAs display other advantages such as rapid performance, simple sample preparation, high throughput, and low cost for sample testing. In recent decades, many immunoassays, including chemiluminescence immunoassay [16], time-resolved fluorescence immunoassay [17], electrochemical immunosensors [18], and immunochromatographic assay [19], have been reported for the detection of AFB1. Furthermore, many direct competitive (dc)- or indirect competitive (ic)-ELISAs based on polyclonal antibodies (pAbs) or monoclonal antibodies (mAbs) for detecting AFB1 have been developed (Table 1) [20,21,22,23,24,25,26,27,28,29,30,31,32,33]. However, establishing a sensitive immunoassay is mainly dependent upon the quality of antibody. Therefore, the research on producing a high-quality antibody against AFB1 has continued in the last thirty years. Furthermore, it is desirable for ELISA to evaluate the total AFs (AFB1, AFB2, AFG1, and AFG2) in agricultural products. In addition, AFB1 may contaminate fish feed, and also accumulate in aquiculture products [34]. Currently, however, the samples for AFB1 testing are mainly focused on agriculture products, and there are few samples involved.
Herein, a highly sensitive and group-specific mAb-based ELISA for the detection of AFB1 in agriculture and aquiculture products was developed. Using the keto carbonyl group that exists in the AFB1 molecule, AFB1 was reacted with o-carboxymethyl hydroxylamine (CMO) to form an oxime, and the carboxylic group in the oxime molecule was used for covalent linking to bovine serum albumin (BSA). The AFB1-BSA conjugate was used as an immunogen to immunize mice. After making great efforts, a mAb with the highest affinity binding for AFB1 was successfully produced by hybridoma technology, and the corresponding ELISA for AFB1 was established. To examine the accuracy and precision of the ELISA, agriculture and aquiculture samples including corn flour, wheat flour, and crab roe were spiked with AFB1, and the spiked samples were subjected to ELISA performance. Acceptable recoveries and relative standard deviation (RSD) of the ELISA for AFB1 in spiked samples were obtained. As the mAb also showed some degree of group specificity with other AFs, to verify the practicability of the ELISA for screening total AFs (AFB1, AFB2, AFG1, and AFG2) in agriculture products, wheat flour samples spiked with the mixed AF standard solution (AFB1, AFB2, AFG1, AFG2) were measured by ELISA and LC-MS/MS simultaneously.

2. Results and Discussion

2.1. Synthesis of Immunogen and Coating Antigen

AFB1 is a small molecular compound without sufficient immunogenicity; thus, to produce an antibody against AFB1, AFB1 should couple to a carrier protein to form an AFB1–protein conjugate. In this study, taking advantage of the keto carbonyl group in the AFB1 molecule, AFB1 was reacted with CMO to form an oxime molecule containing a carboxylic group at one end (Figure S1). Via the carboxylic group and by the carbodiimide method, the AFB1 derivative was covalently coupled to a carrier protein (BSA or OVA) to form an AFB1-BSA (or AFB1-OVA) conjugate. The coupling ratio of AFB1/BSA in AFB1-BSA conjugate was determined by MALDI-TOF-MS. The typical MALDI-TOF-MS spectra of BSA and AFB1–BSA are shown in Figure 1. It can be seen from Figure 1 that the molecular weights of BSA and AFB1-BSA are 65,269 and 67,604, respectively. As the molecular weight of AFB1-CMO is 385, and OH is lost through coupling, the coupling ratio of AFB1/BSA in AFB1-CMO-BSA is estimated to be (67,604 − 65,269)/(385 − 17) = 6.3, which indicates that in each BSA molecule, about 6.3 AFB1 molecules have been linked to the surface of BSA. The MALDI-TOF-MS spectra of OVA and AFB1–OVA are similar to those in Figure 1 and are not given herein. Similar calculation results show that the coupling ratio of AFB1/OVA in AFB1–OVA is 2.9. These results indicate that the AFB1 has been successfully coupled to the carrier proteins with the appropriate coupling ratios in AFB1–protein conjugates.

2.2. Preparation of mAb against AFB1

Six female Balb/c mice were immunized with AFB1–BSA. Seven days after the fifth immunization, the sera were collected and measured by ic-ELISA. Among the six immunized mice, the mouse with the highest titer and inhibition effect was selected for cell fusion. Ten days after cell fusion, five positive cells capable of secreting antibodies against AFB1 were selected by ic-ELISA using AFB1 as a competitor. Among them, the cells (6C6) displayed the highest sensitivity for AFB1; thus, AFB1 was selected for subcloning via the limiting dilution method. The clones (6C6) were expanded and cryopreserved in liquid nitrogen. The large-scale production of mAb was from nude mice ascites. 6C6 hybridoma cells were intraperitoneally injected into nude mice that were pre-injected with liquid paraffin 1 week before. Seven days later, the ascites from the nude mice were collected and purified by the protein G extraction column. The purified mAbs were stored at −20 °C in the presence of 50% glycerol.

2.3. Optimization of ELISA Conditions

In order to achieve high sensitivity, the ELISA conditions, including the dilution of the coating antigen, dilution of the antibody, and GaMIgG-HRP, were optimized based on two criteria, i.e., (1) to achieve an IC50 value as low as possible, and (2) to achieve an absorbance in the range of 0.8–1.5 absorption units for the zero standard concentration according to the Lambert–Beer law. The optimal ELISA conditions were selected by the checkerboard titration method, in which the coating antigen (AFB1–OVA, 1 mg mL−1) was diluted in the range of 1:500~1:10,000, while the dilutions of mAb (6C6) and GaMIgG-HRP were examined in the range of 1:5000~1:80,000 and 1:1000~1:20,000, respectively. The optimal ELISA conditions (e.g., antigen dilution at 1:1000, mAb dilution at 1:10,000, and HRP-GaMigG dilution at 1:5000) were finally obtained.

2.4. Sensitivity of ELISA

Under optimal conditions, the AFB1 standard solutions were applied to ELISA procedures. The standard curve of the ELISA for AFB1 is shown in Figure 2. The average IC50 value calculated from the standard curves obtained from six consecutive measurements is 90 pg mL−1, while the limit of detection (LOD) of the ELISA based on three times the standard deviation (3 × SD) at zero concentration is 18 pg mL−1.
Many mAb (or pAb)-based dc-ELISAs or ic-ELISAs for the detection of AFB1 in different samples have been developed in recent decades (Table 1) [20,21,22,23,24,25,26,27,28,29,30,31,32,33].
As shown in Table 1, the IC50 value achieved in our ELISA (in pg mL−1 level) is lower than most of those obtained in other ELISAs, which clearly demonstrates the high sensitivity of our ELISA. The high sensitivity of the newly produced mAb may be related to the coupling ratio in the immunogen (AFB1–BSA) and in the coating antigen (AFB1–OVA). An appropriate coupling ratio (6.3) of AFB1/BSA in the immunogen may be good for promoting a strong immune response in immunized mice, and thus for producing a high-quality antibody for AFB1. Furthermore, the relatively lower coupling ratio (2.9) of AFB1/OVA in the coating antigen may lead to a lower affinity binding force between the antibody and the coating antigen, which comparatively increases the affinity binding force between the antibody and AFB1, thus increasing the sensitivity further.

2.5. Specificity of the ELISA

The specificity of ELISA was evaluated by the cross-reactivity (CR) of mAb with the homologs of AFB1 (e.g., AFB2, AFG1, AFG2, AFM1, and AFM2) and five other mycotoxins (OTA, ZEN, DON, FB1, and patulin). The CR values of the mAb with these compounds are presented in Table 2. When the CR of the ELISA of AFB1 is considered to be 100%, it can be seen from Table 2 that there is no cross-reactivity (CR < 0.01%) of the mAb with OTA, ZEN, DON, FB1, and PAT, which demonstrates that other mycotoxins in the samples will not interfere with the detection of AFB1 measured by the proposed ELISA. Furthermore, from Table 2 it can be seen that there are some extents of the CR values (1.9~4.3%) of the mAb with AFB1 homologs. Specifically, for AFG1 and AFM1, which contain an olefinic bond in the furan ring, the CR values are 42.5% and 44.3%, respectively; while for AFG2 and AFM2 without the olefinic bond, the CR values are only 1.9% and 4.1%, respectively. These results indicate that the mAb exhibits, to some degree, group specificity with other AFs, and the olefinic bond plays an important role in CR values for AFB1 homologs. For AFB2, although there is no an olefinic bond in the furan ring, due to the high similarity in the molecular structure between AFB1 and AFB2, the CR of the mAb with AFB2 was as much as 23.6%.

2.6. Accuracy and Precision of the ELISA

The ELISA was further characterized by accuracy and precision, which were obtained from the spiking experiment. In this study, wheat flour, corn flour, and crab roe were spiked with AFB1 at the concentrations of 0~40 ng g−1. After extraction, the spiked and unspiked samples were subjected to ELISA procedures. As shown in Table 3, for three unspiked wheat flour, corn flour, and crab roe samples, the blank values were found to be 0.9, 0.21, and 0.37 ng g−1, which are lower than those of the MRL for human consumption set by EU and China. Furthermore, it is shown in Table 3 that the recoveries of the ELISA for AFB1 in spiked samples were 78.3–116.6%, with relative standard deviations (RSDs) of 1.49–13.21% (n = 3). The results reveal the high accuracy and precision of the ELISA for AFB1 in different samples.

2.7. Analysis of Wheat Flour Sample Spiked with Total AFs

Normally, real agricultural samples may contain not only AFB1, but also other types of AFs. To verify the practicability of the proposed ELISA for screening total AFs (AFB1, AFB2, AFG1, and AFG2) in agriculture products, wheat flour samples were spiked with the mixed AF standard solution to give total spiked AF concentrations of 0, 12.5, 25, and 50 ng g−1. The spiked samples were measured by ELISA and LC-MS/MS simultaneously. The concentrations of individual AFs detected by LC-MS/MS are presented in Table S1, and the results of the mixed AF spiked samples measured by LC-MS/MS and ELISA are given in Table 4. From Table 4, it is seen that the concentrations measured by ELISA are about two times lower than those measured by LC-MS/MS, which is due to the fact that the CR values of the ELISA with AFB2, AFG1, and AFG2 are 23.6%, 42.5% and 1.9%, respectively. It is clear that the concentration measured by ELISA is mainly contributed by AFB1 (the CR of the ELISA with AFB1 is considered to be 100%), but AFB2, AFG1, and AFG2 are also contributors, dependent on their CR values. Thus, the proposed ELISA can be used as a screening method for total AFs (AFB1, AFB2, AFG1, and AFG2) in wheat flour samples.

3. Materials and Methods

3.1. Reagents, Materials and Apparatus

AFB1, AFB2, AFG1, AFG2, AFM1, AFM2, ochratoxin A (OTA), zearalenone (ZEN), patulin (PAT), vomiting toxins (DON), and fumonisin B1 (FB1) were purchased from Tanmo Quality Inspection Technology Co., Ltd. (Beijing, China). O-carboxymethyl hydroxylamine (CMO) and pyridine were purchased from China National Pharmaceutical Group Shanghai Co., Ltd. (Shanghai, China). 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC), bovine serum albumin (BSA), ovalbumin (OVA), casein, RPMI-1640 medium, hypoxanthine aminopterin thymidine (HAT), hypoxanthine thymidine (HT), dimethylformamide (DMF), methanol, acetonitrile (ACN), dimethyl sulfoxide (DMSO), 3,3,3,5,5-tetramethylbenzidine (TMB), polyethylene glycol (PEG1500), and Freund’s complete and incomplete adjuvants were purchased from Sigma Co. (St. Louis, USA). The horseradish peroxidase labeled goat anti mouse IgG conjugate (HRP-GaMIgG) was purchased from Zhongshan Jinqiao Biotechnology Co., Ltd. (Beijing, China). Fetal bovine serum (FBS) was purchased from Life Technologies Co. (New York, NY, USA). The mouse SP2/0 myeloma cells were purchased from the cell bank of the Chinese Academy of Sciences (Shanghai, China). Balb/c mice (6–8 weeks old) were obtained from School of Medicine, Soochow University (Suzhou, China). Other chemicals were analytical grade.
Culture plates (24-well and 96-well cell) and cell culture flasks were purchased from Corning Inc. (Corning, NY, USA). The ultra-clean table was purchased from Haier Group (Qingdao, China). The CO2 incubator (HF 151 UV) was purchased from Heal Fore Development Ltd. (Shanghai, China). The spectrophotometer UV-2300 was purchased from Techcomp (Shanghai, China). The ELISA reader (Sunrise Remote/Touch Screen) and microtiter plate washer (M12/2R) were purchased from Columbus plus (Tecan, Grödig, Austria). The microtiter plate shaker (KJ-201C Oscillator) was bought from Kangjian Medical Apparatus, Co., Ltd. (Jiangsu, China). The deionized-RO water supply system (Dura 12FV) was purchased from The Lab Com. (Dover, DE, USA). MALDI-TOF-MS equipment (Micro Q-TOF) was purchased from Bruker Daltonics (Billerica, MA, USA).

3.2. Buffers and Solutions

In this study, the buffers and solutions used were as follows: (1) 0.05 mol L−1 carbonate buffer (pH 9.6) was used as a coating buffer; (2) coating antigen (AFB1-OVA conjugate) stock solution (1.0 mg mL−1) was prepared by dissolving 1.0 mg of AFB1-OVA in 1 mL of coating buffer; (3) assay buffer was 0.01 mol L−1 phosphate buffered saline (PBS, pH 7.4) containing 145 mmol L−1 NaCl; (4) washing buffer (PBST) was the assay buffer with 0.1% (v/v) Tween-20; (5) blocking solution was 1% casein in the assay buffer; (6) acetate buffer was 100 mmol L−1 sodium acetate acid buffer (pH 5.8); (7) substrate solution (TMB + H2O2) was prepared by adding 200 µL of 10 mg mL−1 TMB dissolved in DMSO, 3.5 µL of 30% H2O2 and 1 mL of acetate buffer to 20 mL of ultrapure water; (8) sulfuric acid (5%) was used to stop the enzymatic coloration; (9) AFB1 stock solution (1 mg mL−1) was prepared by dissolving 1.0 mg of AFB1 in 1.0 mL of methanol; (10) AFB1 working solution (1000 ng mL−1) was prepared by diluting AFB1 stock solution (1.0 mg mL−1) with the assay buffer; (11) AFB1 standard solutions with concentrations of 0, 10, 20, 50, 100, 200, 500, and 1000 pg mL−1 were prepared by diluting the AFB1 working solution (1000 ng mL−1) with the assay buffer.

3.3. Synthesis of Immunogen and Coating Antigen

AFB1 is a small molecular compound and does not have enough immunogenicity to stimulate the animal to produce antibodies. However, when AFB1 is coupled to BSA, the AFB1–BSA conjugate will obtain sufficient immunogenicity and can be used as an immunogen to immunize animals to produce antibodies. AFB1 has a keto carbonyl group, which can be easily reacted with CMO to form an oxime (Figure S1). Then, the carboxylic group in the oxime molecule can react with the amino group in BSA to form an amide bond. Briefly, 2 mg of AFB1 and 4 mg of CMO were added to 0.4 mL of pyridine, and the solution was stirred at 25 °C for 24 h. Thin-layer chromatography (TLC) was employed to check whether AFB1 had been fully reacted with CMO. After the reaction was complete, pyridine in the solution was evaporated by a nitrogen stream, and the dried residue containing the resultant oxime was obtained. AFB1–oxime was completely dissolved in 1.5 mL of DMF-water (1:1, v/v); then, 27.6 mg of EDC was added and mixed well in the dark. Subsequently, 2.8 mL of 0.13 mol L−1 NaHCO3 solution containing 14 mg of BSA was added. The solution was slightly stirred at 25 °C for 4 h, then 26 mg of EDC was added again and the reaction was continued for 24 h. The solution was transferred into a dialysis bag, and dialyzed at 4 °C for 3 days in a 0.01 mol L−1 PBS solution (pH 7.4) and for 1 day in ultrapure water. After dialysis, the dialyzed solution was centrifuged at 7000 r min−1 for 10 min, and the supernatant was lyophilized to a powder form. The synthesized AFB1–BSA conjugate was stored at −20 °C until use. Similarly, the AFB1–OVA conjugate was synthesized. The AFB1–BSA conjugate was used as the immunogen for mAb production, while the AFB1–OVA conjugate was used as the coating antigen for the establishment of ic-ELISA.

3.4. Production of mAb against AFB1

The mAb against AFB1 was produced using the hybridoma technique. Six female Balb/c mice (6–8 weeks) were immunized with multiple subcutaneous injections of AFB1–BSA. In the first immunization, AFB1–BSA dissolved in physiological saline was emulsified with Freund’s complete adjuvant (1:1). Each mouse received an immunogen dose of 100 μg. The interval between two immunizations was 21 days. In the 2nd~4th booster immunizations, 100 μg of AFB1–BSA emulsified with incomplete Freund’s adjuvant (1:1) was given to each mouse. Seven days after the 3rd immunization, blood was collected from the tail of the immunized mice, and the titer and the inhibitory effect of the antisera were measured by ic-ELISA using AFB1–OVA as the coating antigen and AFB1 as the competitor, respectively. Three days before cell fusion, the mice were given the final booster injection intraperitoneally with 100 μg of AFB1–BSA without adjuvant. The mouse with the highest titer and inhibitory effect was selected for cell fusion. The mouse was sacrificed via cervical dislocation, and the spleen lymphocytes were evenly mixed with myeloma cells (SP2/0) at a 10:1 ratio and fused in 50% polyethylene glycol PEG4000 under aseptic conditions. The cell suspension was dispersed in 96-well cell culture plates containing RPMI-1640 medium, 20% fetal bovine serum, and 1% HAT (v/v), and cultured in an incubator at 37 °C with 5% CO2. The culture medium was changed every 3 days. After 10 days of cell culture, there were a large number of cells in the wells. The ic-ELISA was used to screen positive hybridoma cells that were able to specifically secrete antibodies against AFB1, and subcloning was performed using the limit dilution method. After subcloning, a large number of pure hybridoma cells capable of secreting antibodies were obtained. Stable mAb-producing clones were expended and cryopreserved in liquid nitrogen. Parts of the stable subclones were injected into the abdominal cavity of nude Balb/c mice to generate a large amount of mAb.
Animal welfare and experimental procedures were strictly carried out according to recommendations in the Guide for the Care and Use of Laboratory Animals (23a) of the National Institutes of Health. All protocols were approved through the Institutional Animal Care and Use Committee (IACUC) of Soochow University. All efforts were made to minimize animal suffering and to reduce the number of animals used.

3.5. Procedures of ELISA

The ELISA procedures were as follows. AFB1–OVA diluted with coating buffer was added to a 96-well microplate (200 μL/well). The plate was placed at 4 °C overnight. After washing the plate three times with PBST, 280 μL/well of 1% casein was added to the plate to block the possible non-specific binding sites. After 1 h, the plate was washed with PBST three times. Then, the AFB1 standard solution (100 μL/well) and mAb solution (diluted with assay buffer, 100 μL/well) were added to the plate. The plate was slightly shaken at room temperature for 1 h. After washing the plate three times again, HRP-GaMIgG solution (200 μL/well) was added. The plate was placed at room temperature for 1 h, then washed with PBST three times. After washing the plate again, the enzymatic substrate solution (200 μL/each well) was added. The plate was slightly shaken for 15–20 min at room temperature. After washing, 80 μL/well of sulfuric acid (5%) was added to terminate the enzymatic reaction. The plate was slightly shaken for about 15 min at room temperature. The absorbances in the wells of the plate were measured with the ELISA reader at 450 nm. The standard curve of the ELISA for AFB1 was constructed by plotting the (B/B0) × 100% ~ log CAFB1, where B and B0 were the absorbances of the standard solution and zero concentration, respectively. From the standard curve, the IC50 (e.g., the AFB1 concentration that produces 50% signal inhibition) can be obtained. A lower IC50 value indicates higher sensitivity of the ELISA. The sample solution was subjected to the same ELISA procedures, and the concentration of AFB1 in the sample was calculated according to the standard curve obtained from the same plate.

3.6. Cross-Reactivity Testing

The specificity of the ELISA can be evaluated by cross-reactivity (CR) values. Besides AFB1, five AFs homologs (AFB2, AFG1, AFG2, AFM1, and AFM2) and other main mycotoxins including OTA, ZEN, DON, FB1, and PAT, were selected to test the CR (Table 2). The standard solutions of AFB1, AFB2, AFG1, and AFM1 were prepared in the concentration range of 10~1000 pg mL−1, while the standard solutions of AFG2 and AFM2 were in the range of 0.1~10 ng mL−1, and the standard solutions of OTA, ZEN, DON, FB1, and PAT were in the range of 10~10,000 ng mL−1. The standard solutions of the tested compounds were subjected to ELISA procedures. The values of IC50 can be obtained from the corresponding standard curves for every testing compound. The CR (%) was calculated based on the equation: CR (%) = (IC50 of AFB1/IC50 of the tested compound) × 100%.

3.7. Spiking Experiment

To examine the accuracy and precision of the ELISA, a spiking experiment was carried out. Wheat flour, corn flour, and crab roe were selected for the spiking experiment. Wheat flour and corn flour are normal food commodities, while crab is a popular aquiculture product enjoyed by the local people in the Suzhou area. It is possible that when the feed for crab farming is contaminated by AFB1, the toxic AFB1 can be accumulated in crab roe. Wheat flour, corn flour, and crab roe were purchased from the local market, and were spiked with AFB1 at the concentrations of 0~40 ng g−1. (Table 3). The spiked and unspiked samples were extracted, and then subjected to ELISA procedures. Briefly, to 4 glass tubes containing 2 g of wheat flour (or corn flour or homogenized crab roe), different volumes of AFB1 standard solution (1000 ng mL−1) were added (wheat flour: 0, 4, 10, and 20 μL; corn flour: 0, 20, 40, and 80 μL; crab roe: 0, 20, 40, and 80 μL). The tubes were intensively shaken at room temperature for 1 h, then 10 mL of ACN solution (ACN:water = 8:2, v/v) was added. The tubes were shaken at room temperature for 30 min, then centrifuged at 3000 r min−1 for 15 min. The supernatants were diluted with PBS at 1:10~1:200 to ensure the final concentration of AFB1 fell within the ELISA detection range. The diluted solutions were subjected to ELISA procedures. For each sample, three separate extractions were performed, and each sample was determined in triplicate. Recoveries were calculated based on the following equation: Recovery (%) = [(Conc. measured − blank)/Conc. spiked] × 100%.

3.8. Analysis of Wheat Flour Sample Spiked with Total AFs

Due to some degree of group specificity of the mAb with other AFs, to verify the proposed ELISA for screening total AFs (AFB1, AFB2, AFG1, and AFG2) in agriculture products, wheat flour samples spiked with the mixed AF standard solution (containing AFB1, AFB2, AFG1, and AFG2 with the concentrations of 200, 50, 200, and 50 ng mL−1, respectively) were simultaneously measured by ELISA and LC-MS/MS. Briefly, to 4 glass tubes containing 5 g of wheat flour, 0, 0.125, 0.25, and 0.5 mL of mixed AF standard solution were added, respectively, so that the AFB1 and AFG1 contents spiked in the tubes were 0, 5, 10, and 20 ng g−1, and the AFB2 and AFG2 contents were 0, 1.25, 2.5, and 5 ng g−1, (e.g., the total AF contents spiked in the tubes were 0, 12.5, 25, and 50 ng g−1, respectively) (Table 4). The samples were extracted with a methanol:water (8:2, v/v) solution, and subjected to a commercial immuno-affinity column (AflaOchraStarTM, Romer Labs, Getzersdorf, Austria) for clean-up. The elutes were measured by LC-MS/MS and ELISA.

3.9. LC-MS/MS Analysis

Chromatographic separation was performed on a Waters UPLC system (Waters Corporation, Product of Singapore) consisting of two pumps, a cooled autosampler, a column oven, and a column (Waters Acquity UPLC HSS T3, 100 mm × 2.1 mm I.D, 1.8 μm). Mobile phase A was Milli-Q water containing 0.1% formic acid water, and mobile phase B was methanol. A binary gradient system with a flow rate of 0.3 mL/min was established. The gradient steps were as follows: 5% B for 0–0.2 min, linear increase from 5 to 90% B for 0.2–4 min and holding for 6 min; 5% B for 6–8 min followed by re-equilibration of the column for 2 min.
A 5500 Triple Quad tandem mass spectrometer (AB Sciex, Framingham, MA, USA) equipped with a TurboIon Spray electrospray ion (ESI) source was used for detection. Sample introduction and ionization was conducted in the positive ion mode. The MS parameters were as follows: 5.5 kV ion spray voltage, 30 psi curtain gas pressure, 55 psi pressure for the nebulizer (gas1) and 65 psi pressure for the turbo (gas 2), 550 °C turbo heater temperature, 100 V declustering potential (DP). Collision energies of disparate analytes were optimized (AFB1: m/z 313.1–269, 40 eV; m/z 313.1–241.1, 47 eV; dwell time of 150 ms) using an automatic function of Analyst software 1.6.2 (AB Sciex). Data were acquired in multiple reaction monitoring (MRM) mode, and the scheduled MRM function was used as the acquisition method to ensure enough acquisition points (at least 12 points for each peak). The calibration curve for AFs was constructed with standards of 0.1, 0.5, 1.0, 2.0, 5.0, 8.0, and 10 ng mL−1.

4. Conclusions

A highly sensitive (at the pg mL−1 level) and group-specific ELISA using newly prepared mAb for the detection of AFB1 in the samples of agriculture and aquiculture products was described. The IC50 and LOD of the ELISA for AFB1 were 90 pg mL−1 and 18 pg mL−1, respectively, which were lower than those of most published ELISAs. There was no cross-reactivity (CR < 0.01%) of the assay with OTA, ZEN, DON, FB1, and PAT, but there was some extent of the CR values of the assay with AFB1 homologs, indicating the ELISA was able to evaluate total AF in agriculture samples. Accepted recoveries and RSD values of the ELISA for AFB1 in spiked agriculture and aquiculture samples were obtained. Wheat flour samples spiked with the mixed AF (AFB1, AFB2, AFG1, and AFG2) standard solution were measured by ELISA and LC-MS/MS simultaneously. It was demonstrated that the proposed ELISA was able to evaluate the total AF (AFB1, AFB2, AFG1, and AFG2) in wheat flour samples.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/molecules29102280/s1, Figure S1: Synthesis of AFB1–BSA conjugat; Table S1: Wheat flour sample spiked with AFs and measured by LC-MS/MS.

Author Contributions

Conceptualization, A.D., J.L. and K.W.; methodology, J.C.; validation, J.C., T.W., F.Z. and Y.F.; formal analysis, J.C.; investigation, J.C.; writing—review and editing, A.D. and J.L.; supervision, A.D., J.L. and K.W. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Natural Science Foundation of China (NSFC, contact nos. 21175097 and 31772053), the Supporting Funds for key research and development Project of the Ministry of Science and Technology (5010900122) and a Project Funded by the Priority Academic Program development of Jiangsu Higher Education Institutions (No. YX10900212).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are contained within the article and Supplementary Materials.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Pisoschi, A.M.; Iordache, F.; Stanca, L.; Petcu, A.I.; Purdoiu, L.; Geicu, O.I.; Bilteanu, O.I.; Serban, A.I. Comprehensive overview and critical perspective on the analytical techniques applied to aflatoxin determination–a review paper. Microchem. J. 2023, 191, 108770. [Google Scholar] [CrossRef]
  2. González-Curbelo, M.Á.; Kabak, B. Occurrence of mycotoxins in dried fruits worldwide, with a focus on aflatoxins and ochratoxin A: A review. Toxins 2023, 15, 576. [Google Scholar] [CrossRef]
  3. Abbas, H.K.; Accinelli, C.; Shier, W.T. Biological control of aflatoxin contamination in US crops and the use of bioplastic formulations of aspergillus flavus biocontrol strains to optimize application strategies. J. Agric. Food Chem. 2017, 65, 7081–7087. [Google Scholar] [CrossRef] [PubMed]
  4. Kumar, V.V. Aflatoxins: Properties, toxicity and detoxification. Nutr. Food Sci. Int. J. 2018, 6, 555696. [Google Scholar]
  5. Benkerroum, N. Aflatoxins: Producing-molds, structure, health issues and incidence in southeast asian and sub-saharan african countries. Int. J. Environ. Res. Public Health 2020, 17, 1215. [Google Scholar] [CrossRef] [PubMed]
  6. Zitomer, N.; Rybak, M.E.; Li, Z.; Walters, M.J.; Holman, M.R. Determination of aflatoxin B1 in smokeless tobacco products by use of UHPLC-MS/MS. J. Agric. Food Chem. 2015, 63, 9131–9138. [Google Scholar] [CrossRef] [PubMed]
  7. Sun, L.L.; Zhao, Q. Direct fluorescence anisotropy approach for aflatoxin B1 detection and affinity binding study by using single tetramethylrhodamine labeled aptamer. Talanta 2018, 189, 442–450. [Google Scholar] [CrossRef]
  8. Ventura, M.; Gómez, A.; Anaya, I.; Díaz, J.; Broto, F.; Agut, M.; Comellas, L. Determination of aflatoxins B1, G1, B2 and G2 in medicinal herbs by liquid chromatography-tandem mass spectrometry. J. Chromatogr. A 2004, 1048, 25–29. [Google Scholar]
  9. European Commission. Commission Regulation (EC) No. 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. Off. J. Eur. Union 2006, L364, 20–23. [Google Scholar]
  10. GB2761-2017; Chinese National Food Safety Standard, Maximum Residue Limits for Mycotoxins in Food. National Medical Products Administration: Beijing, China, 2017.
  11. Liu, S.Y.; Qiu, F.; Kong, W.J.; Wei, J.; Xiao, X.H.; Yang, M.H. Development andvalidation of an accurate and rapid LC-ESI-MS/MS method for the simultaneous quantification of aflatoxin B1, B2, G1 and G2 in lotus seeds. Food Control 2013, 29, 156–161. [Google Scholar] [CrossRef]
  12. Miró-Abella, E.; Herrero, P.; Canela, N.; Arola, L.; Borrull, F.; Ras, R.; Fontanals, N. Determination of mycotoxins in plant-based beverages using QuEChERS and liquid chromatography–tandem mass spectrometry. Food Chem. 2017, 229, 366–372. [Google Scholar] [CrossRef]
  13. Khayoon, W.S.; Saad, B.; Lee, T.P.; Salleh, B. High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column. Food Chem. 2012, 133, 489–496. [Google Scholar] [CrossRef] [PubMed]
  14. Cao, B.Y.; He, G.Z.; Yang, H.; Chang, H.F.; Li, S.Q.; Deng, A.P. Development of a highly sensitive and specific enzyme-linked immunosorbent assay (ELISA) for the detection of phenylethanolamine A in tissue and feed samples and confirmed by liquid chromatography tandem mass spectrometry (LC–MS/MS). Talanta 2013, 115, 624–630. [Google Scholar] [CrossRef]
  15. Pu, C.; Wu, Y.F.; Yang, H.; Deng, A.P. Trace analysis of contraceptive drug levonorgestrel in wastewater samples by a newly developed indirect competitive enzyme-linked immunosorbent assay (ELISA) coupled with solid phase extraction. Anal. Chim. Acta 2008, 628, 73–79. [Google Scholar] [CrossRef]
  16. Li, J.; Zhao, X.; Chen, L.J.; Qian, H.L.; Wang, W.L.; Yang, C.; Yan, X.P. p-bromophenol-enhanced bienzymatic chemiluminescence competitive immunoassay for ultrasensitive determination of aflatoxin B1. Anal. Chem. 2019, 91, 13191–13197. [Google Scholar] [CrossRef]
  17. Wang, X.; Lu, D.S.; Huang, Q.F.; Yang, J.Y. Microfluidics-based time-resolved fluorescence immunoassay for the on-site detection of aflatoxins B1 zearalenone and deoxynivalenol in cereals. Foods 2022, 11, 1319. [Google Scholar] [CrossRef]
  18. Liu, X.; Wen, Y.P.; Wang, W.J.; Zhao, Z.T.; Han, Y.; Tang, K.J.; Wang, D. Nanobody-based electrochemical competitive immunosensor for the detection of AFB1 through AFB1-HCR as signal amplifier. Microchim. Acta 2020, 187, 1–10. [Google Scholar] [CrossRef] [PubMed]
  19. Mao, X.Y.; Yu, B.G.; Li, Z.J.; Li, Z.P.; Shi, G.Q. Comparison of lateral flow immunoassays based on oriented and nonoriented immobilization of antibodies for the detection of aflatoxin B1. Anal. Chim. Acta 2022, 1221, 340135. [Google Scholar] [CrossRef]
  20. Kolosova, A.Y.; Shim, W.B.; Yang, Z.Y.; Eremin, S.A.; Chung, D.H. Direct competitive ELISA based on a monoclonal antibody for detection of aflatoxin B1. Stabilization of ELISA kit components and application to grain samples. Anal. Bioanal. Chem. 2006, 384, 286–294. [Google Scholar] [CrossRef]
  21. Burkin, M.A.; Yakovleva, I.V.; Sviridov, V.V.; Burkin, A.A.; Kononenko, G.P.; Soboleva, N.A. Comparative immunochemical characterization of polyclonal and monoclonal antibodies to aflatoxin B1. Appl. Biochem. Microbiol. 2000, 36, 496–501. [Google Scholar] [CrossRef]
  22. Burkin, A.A.; Kononenko, G.P.; Soboleva, N.A.; Zotova, E.V. An enzyme immunoassay system for aflatoxin B1. Appl. Biochem. Microbiol. 2000, 36, 80–84. [Google Scholar] [CrossRef]
  23. Lee, N.A.; Rachmawati, S. A rapid ELISA for screening aflatoxin B1 in animal feed and feed ingredients in Indonesia. Food Agr. Immunol. 2006, 17, 91–104. [Google Scholar] [CrossRef]
  24. Chen, F.S.; Zhou, Q. Comparative study on the characterization of antisera of anti-aflatoxin B1 from rabbit and laying hen. Food/Nahrung. 2002, 46, 432–436. [Google Scholar] [CrossRef]
  25. Reddy, S.V.; Kiran Mayi, D.; Uma Reddy, M.; Thirumala-Devi, K.; Reddy, D.V.R. Aflatoxins B1 in different grades of chillies (Capsicum annum L.) in India as determined by indirect competitive-ELISA. Food Addit. Contam. 2001, 18, 553–558. [Google Scholar] [CrossRef]
  26. Jiang, W.X.; Wang, Z.H.; Nölke, G.; Zhang, J.; Niu, L.L.; Shen, J.Z. Simultaneous determination of aflatoxin B1 and aflatoxin M1 in food matrices by enzyme-linked immunosorbent assay. Food Anal. Meth. 2013, 6, 767–774. [Google Scholar] [CrossRef]
  27. Liu, B.H.; Hsu, Y.T.; Lu, C.C.; Yu, F.Y. Detecting aflatoxin B1 in foods and feeds by using sensitive rapid enzyme-linked immunosorbent assay and gold nanoparticle immunochromatographic strip. Food Control 2013, 30, 184–189. [Google Scholar] [CrossRef]
  28. Anfossi, L.; Di Nardo, F.; Giovannoli, C.; Passini, C.; Baggiani, C. Enzyme immunoassay for monitoring aflatoxins in eggs. Food Control 2015, 57, 115–121. [Google Scholar] [CrossRef]
  29. Liu, J.W.; Lu, C.C.; Liu, B.H.; Yu, F.Y. Development of novel monoclonal antibodies-based ultrasensitive enzyme-linked immunosorbent assay and rapid immunochromatographic strip for aflatoxin B1 detection. Food Control 2016, 59, 700–707. [Google Scholar] [CrossRef]
  30. Yamasaki, T.; Miyake, S.; Sato, N.; Hirakawa, Y.; Iwasa, S.; Narita, H.; Watanabe, T. Development of enzyme-linked immunosorbent assay for analysis of total aflatoxins based on monoclonal antibody reactive with aflatoxins B1, B2, G1 and G2. Food Hyg. Saf. Sci. 2018, 59, 200–205. [Google Scholar] [CrossRef]
  31. Zhang, X.; Feng, M.; Liu, L.Q.; Xing, C.R.; Kuang, H.; Peng, C.F.; Wang, L.B.; Xu, C.L. Detection of aflatoxins in tea samples based on a class-specific monoclonal antibody. Int. J. Food Sci. Technol. 2013, 48, 1269–1274. [Google Scholar] [CrossRef]
  32. Lee, N.A.; Wang, S.; Allan, R.D.; Kennedy, I.R. A Rapid Aflatoxin B1 ELISA: Development and validation with reduced matrix effects for peanuts, corn, pistachio, and soybeans. J. Agric. Food Chem. 2004, 52, 2746–2755. [Google Scholar] [CrossRef] [PubMed]
  33. Ye, Y.; Liu, A.P.; Wang, X.H.; Chen, F.S. Spectra analysis of coating antigen: A possible explanation for difference in anti-AFB1 polyclonal antibody sensitivity. J. Mol. Struct. 2016, 1121, 74–79. [Google Scholar] [CrossRef]
  34. Thilini Madurangika Jayasinghe, G.D.; Domínguez-Gonzalez, R.; Bermejo-Barrera, P.; Moreda-Pineiro, A. Room temperature phosphorescent determination of aflatoxins in fish feed based on molecularly imprinted polymer-Mn-doped ZnS quantum dots. Anal. Chim. Acta 2020, 1103, 183–191. [Google Scholar] [CrossRef] [PubMed]
Figure 1. MALDI-TOF-MS spectra of BSA and AFB1-BSA. The m/z values of BSA and AFB1-BSA are 65,269 and 67,604, respectively.
Figure 1. MALDI-TOF-MS spectra of BSA and AFB1-BSA. The m/z values of BSA and AFB1-BSA are 65,269 and 67,604, respectively.
Molecules 29 02280 g001
Figure 2. Standard curve of the ELISA for AFB1 detection under optimal experimental conditions. The bars represent the standard derivations of the values of B/B0 × 100% (n = 5). The IC50 was 90 pg mL−1, and the LOD was 18 pg mL−1.
Figure 2. Standard curve of the ELISA for AFB1 detection under optimal experimental conditions. The bars represent the standard derivations of the values of B/B0 × 100% (n = 5). The IC50 was 90 pg mL−1, and the LOD was 18 pg mL−1.
Molecules 29 02280 g002
Table 1. Comparison of published ELISAs with this work for AFB1 detection.
Table 1. Comparison of published ELISAs with this work for AFB1 detection.
ELISAAntibodySampleIC50
(ng mL−1)
LOD
(ng mL−1)
Ref.
dc-ELISAmAbRice0.620.05[20]
ic-ELISAmAbFood0.33/[21]
ic-ELISApAbFood10/[22]
dc-ELISApAbFeed0.850.18[23]
dc-ELISApAbCorn, wheat, peanut1.1/[24]
ic-ELISApAbChilli1.2/[25]
ic-ELISAmAbPeanuts, corn, rice, etc.0.13/[26]
dc-ELISApAbFood, Feed0.15/[27]
dc-ELISApAbEgg0.24/[28]
dc-ELISAmAbrice, pet food, peanut, etc.0.051/[29]
dc-ELISAmAbPeanuts0.09/[30]
ic-ELISAmAbTea0.057/[31]
dc-ELISApAbPeanuts, Corn, etc.0.8/[32]
ic-ELISApAbFood1.4/[33]
ic-ELISAmAbWheat, corn, Crab roe0.090.018This work
Table 2. Cross-reactivity (CR) of the ELISA with six types of aflatoxins and five other types of fungal toxins.
Table 2. Cross-reactivity (CR) of the ELISA with six types of aflatoxins and five other types of fungal toxins.
CompoundMolecular StructureIC50 (ng mL−1)CR (%)
AFB1Molecules 29 02280 i0010.090100
AFB2Molecules 29 02280 i0020.38123.6
AFG1Molecules 29 02280 i0030.21242.5
AFG2Molecules 29 02280 i0044.7561.9
AFM1Molecules 29 02280 i0050.20344.3
AFM2Molecules 29 02280 i0062.1904.1
PATMolecules 29 02280 i007>1000<0.01
FB1Molecules 29 02280 i008>1000<0.01
ZENMolecules 29 02280 i009>1000<0.01
DONMolecules 29 02280 i010>1000<0.01
OTAMolecules 29 02280 i011>1000<0.01
Table 3. The recoveries of the AFB1 from spiked samples measured by ELISA.
Table 3. The recoveries of the AFB1 from spiked samples measured by ELISA.
SampleCon. Spiked
(ng g−1)
Con. Measured
±SD (ng g−1)
Recovery
(%)
RSD
(%, n = 3)
Wheat flour00.90 ± 0.05/5.56
23.21 ± 0.08115.502.49
56.73 ± 0.10116.601.49
1011.27 ± 0.93103.708.25
Corn flour00.21 ± 0.01/4.76
1010.44 ± 0.75102.307.18
2021.51 ± 0.32106.501.49
4038.45 ± 0.6295.601.61
Crab roe00.37 ± 0.10/27.03
108.20 ± 0.4078.304.88
2020.67 ± 2.73101.5013.21
4037.67 ± 3.0793.238.15
Table 4. Wheat flour sample spiked with mixed AFs measured by LC-MS/MS and ELISA.
Table 4. Wheat flour sample spiked with mixed AFs measured by LC-MS/MS and ELISA.
Conc. of Total AFs Spiked
(ng g−1)
Conc. of Total AFs Measured by
LC-MS/MS
(ng g−1)
Conc. Measured by ELISA
(ng g−1)
02.460.25 ± 0.03
12.512.165.67 ± 0.33
2523.2112.73 ± 1.13
5047.2524.00 ± 2.80
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Cao, J.; Wang, T.; Wu, K.; Zhou, F.; Feng, Y.; Li, J.; Deng, A. A Highly Sensitive and Group-Specific Enzyme-Linked Immunosorbent Assay (ELISA) for the Detection of AFB1 in Agriculture and Aquiculture Products. Molecules 2024, 29, 2280. https://doi.org/10.3390/molecules29102280

AMA Style

Cao J, Wang T, Wu K, Zhou F, Feng Y, Li J, Deng A. A Highly Sensitive and Group-Specific Enzyme-Linked Immunosorbent Assay (ELISA) for the Detection of AFB1 in Agriculture and Aquiculture Products. Molecules. 2024; 29(10):2280. https://doi.org/10.3390/molecules29102280

Chicago/Turabian Style

Cao, Junlin, Ting Wang, Kang Wu, Fengjie Zhou, Yuze Feng, Jianguo Li, and Anping Deng. 2024. "A Highly Sensitive and Group-Specific Enzyme-Linked Immunosorbent Assay (ELISA) for the Detection of AFB1 in Agriculture and Aquiculture Products" Molecules 29, no. 10: 2280. https://doi.org/10.3390/molecules29102280

APA Style

Cao, J., Wang, T., Wu, K., Zhou, F., Feng, Y., Li, J., & Deng, A. (2024). A Highly Sensitive and Group-Specific Enzyme-Linked Immunosorbent Assay (ELISA) for the Detection of AFB1 in Agriculture and Aquiculture Products. Molecules, 29(10), 2280. https://doi.org/10.3390/molecules29102280

Article Metrics

Back to TopTop