Review

Cell-Electrospinning and Its Application for Tissue Engineering

Department of Biomechatronic Engineering, Sungkyunkwan University (SKKU), Suwon-si, Gyeonggi-do 16419, Korea
*
Author to whom correspondence should be addressed.
The authors contributed equally to this work.
Int. J. Mol. Sci. 2019, 20(24), 6208; https://doi.org/10.3390/ijms20246208
Submission received: 31 October 2019 / Revised: 5 December 2019 / Accepted: 5 December 2019 / Published: 9 December 2019
(This article belongs to the Special Issue Nano/Micro-Assisted Regenerative Medicine 2.0)

Abstract

:
Electrospinning has gained great interest in the field of regenerative medicine, due to its fabrication of a native extracellular matrix-mimicking environment. The micro/nanofibers generated through this process provide cell-friendly surroundings which promote cellular activities. Despite these benefits of electrospinning, a process was introduced to overcome the limitations of electrospinning. Cell-electrospinning is based on the basic process of electrospinning for producing viable cells encapsulated in the micro/nanofibers. In this review, the process of cell-electrospinning and the materials used in this process will be discussed. This review will also discuss the applications of cell-electrospun structures in tissue engineering. Finally, the advantages, limitations, and future perspectives will be discussed.

1. Introduction

Tissue engineering has achieved noteworthy advancements in regenerating human organs and tissues ever since it was introduced. Tissue engineering focusses on restoring or improving the function of defective tissues by developing biological substitutes, comprising scaffolds, cells, and biofactors [1]. Therefore, the scaffolds are expected to provide a cell-friendly environment from micro- to nanoscale to guide cells into the targeted tissue or organ and enable them to mature. For this reason, various methods have been investigated to design bioscaffolds that simulate the environment of the native tissue.
Electrospinning (ES) is one well-known method of fabricating scaffolds that comprise micro/nanofibers. The early concept of electrospinning was proposed in the 1930s by Anton Formhals. Since its introduction, it has been used in various fields, such as aerospace applications, agriculture, filtration, and textile [2,3,4,5,6]. ES is based on the use of electrical forces to produce fibers with sizes ranging from micro- to nanometers. An electrospinning process basically requires three components, namely a nozzle tip attached to a high voltage direct current (HVDC) source, a flow rate controller, and a grounded collector, as illustrated in Figure 1a [7]. When the electric field is applied between the nozzle tip and the grounded collector, a microsphere is formed at the end of the nozzle. As the strength of the electric field increases, the microsphere at the tip elongates forming a conical shape called the Taylor cone. The electrostatic force within the Taylor cone becomes greater than the surface tension, thereby generating a liquid jet from the cone. The jet undergoes bending instabilities, causing the whipping of fibers, resulting in a randomly oriented fibrous mat [8]. These micro/nano-sized fibers provide a large surface area-to-volume ratio, which can enhance cellular activities, such as cell attachment, proliferation, and differentiation [9]. Moreover, these electrospun scaffolds simulate the native structure of an extracellular matrix (ECM), which demonstrates a vital role in cell functions, such as cell survival, polarity, proliferation, migration and differentiation [10,11]. ECM also plays an important role in cell–ECM interaction, transducing extracellular information into intracellular events (Figure 1b) [12,13].
Consequently, electrospun fibers are widely used in biomedical applications to regenerate various tissues. For example, Chong et al. used a polycaprolactone (PCL)/gelatin blend to develop an artificial skin layer using the ES method. In this study, PCL provided mechanical stability, while gelatin was included to increase the biocompatibility of the electrospun scaffolds [14]. In another study, a collagen/chitosan/poly(L-lactic acid-co-ε-caprolactone) (PLLA-CL) blend was electrospun to fabricate a vascular graft. Though collagen and chitosan provided superior biocompatibility, they demonstrated poor mechanical properties, and therefore, PLLA-CL was employed [15]. Some tissues, such as muscles, nerves, and tendons, are composed of highly aligned structures. Therefore, many studies have been conducted to generate aligned fibers. Aviss et al. used a rotating mandrel as the grounded collector to achieve aligned poly(lactide-co-glycolide) fibers for skeletal muscle regeneration. The diameter of the fiber could be adjusted by varying the rotational speed of the mandrel orientation [16]. Another method involved depositing PCL fibers in the gap that separates two grounded poles. The fibers were aligned by moving back and forth between the poles, resulting in an aligned PCL bundle. This 3D fibrous bundle was fabricated for nerve regeneration [17]. ES has gained significant interest in biomedical applications due to the aforementioned benefits. Nevertheless, it demonstrates some limitations, such as usage of toxic solvents, poor cell infiltration, and inhomogeneous cell-distribution.
To overcome these limitations, a novel method, called cell-electrospinning (C-ES), was introduced. C-ES is an electrospinning-based technique that generates fibers with living cells embedded within (Figure 1(c)) [18]. The major difference between conventional ES and C-ES involves the use of viable cells. To elaborate, C-ES was firstly introduced by Jayasinghe et al. in 2006, to demonstrate the feasibility of developing active biological scaffolds using a modified ES process [18]. In this study, astrocytoma (1321N1) cells were embedded in cell suspension, which was supplied to the inner needle of the core–shell nozzle. The polydimethylsiloxane solution was supplied to the outer needle to enhance the mechanical properties of the cell-laden fibers. The cell viability was measured as 67.6 ± 1.9%, which was close to the genuine viability (~70%) of astrocytoma cells. The metabolic activities and cell proliferation were maintained for six days, and the compatibility of C-ES was established. This concept was then expanded by using various types of cells (adipose stem cells, osteoblasts, cardiac myocytes, and neuroblastoma) and various biocompatible materials (polyvinyl alcohol (PVA), alginate, and Matrigel) [19,20,21,22]. As the possibility of the C-ES process has been revealed, a comprehensive investigation is required to apply this process for realistic biomedical applications.
In this mini-review, we extensively investigate the C-ES process. Firstly, the processing of C-ES is introduced and the parameters affecting the process are discussed. The biomaterials used in the C-ES process are also described. Secondly, we introduce several applications of the C-ES process for biomedical purposes. Finally, the advantages, limitations, and future perspectives of C-ES are presented.

2. Processing of C-ES

Several critical conditions, such as the viscosity of the bioink, the applied electric field, the feeding rate of the bioink, the distance between the tip of the nozzle to collector, and environmental factors, influence the C-ES process.

2.1. Material Parameters

The viscosity and surface tension of the printing solution are important to the development of cell-loaded fibers using C-ES. The viscosity of the bioink not only affects the cell-embedding efficiency, but also the printability [23]. Generally, low-viscosity bioinks are advantageous, as higher viscosities result in greater shear stress which can negatively affect the cells [24]. Kim et al. observed a significant decrease in cell viability (<80%) when the collagen content in the bioink was greater than 7 wt% [25], while a high cell viability (of 93%) was achieved when the collagen weight percent was less than 5. However, bioink with a very low viscosity may cause the spraying of solution droplets instead of generating fibers [26,27].
In the conventional ES process, the surface tension is controlled by changing the polymer/solvent ratio of the solution [27]. In a study by Lee et al., the surface tension was dependent on the volume ratio of the two solvents (methylene chloride and N,N-dimethylformamide) used for PCL electrospinning [28]. In general, solvents may damage the viable cells, rendering them unsuitable for C-ES [29]. Therefore, selecting the polymers for proper solution conductivity is critical.

2.2. Process Parameters

One of the most important parameters in ES-based techniques is electric field, without which electrospinning is impossible [8]. As C-ES involves the fabrication of cell-embedded fibers, the strength of the electric field is of very significant. In ES, the use of the electric field is considered as a parameter affecting the generation of fibers, while cell viability is also considered during the E-CS process. Strong electric fields may cause low cell viability [21,30]. For instance, high cell viability (90%) was achieved when the electric field was in the range of 0.05–0.075 –kV/mm. However, a significant drop in cell viability was observed when the strength of the electric field was increased [30]. In contrast, weak electric fields may result in inappropriate fiber formation [21,30]. In another study, the application of a low electric field (0.1 kV/mm) resulted in high cell viability (90%); however, the microfibers generated were not well-developed [21]. Therefore, the distance between the tip of the nozzle to the collector—which influences the electric field—is also an important variable [31]. Another parameter that affects the C-ES process is the flow rate of the solution. The flow rate is vital, not only for fiber formation, but also to achieve a high cell viability. It is also closely related to shear stress, and therefore, should be determined depending on the material.
In addition, some environmental factors, such as temperature and humidity, may influence the C-ES process. Temperature, especially, may affect the cell viability and the rheological properties of the bioink. In terms of cell viability, the temperature of the printing environment may affect the cells during the holding time [32]. Moreover, it is prominent that the rheological properties are affected by temperature [33]. It was reported that the synergistic effects of decreased viscosity and decreased surface tension affected fiber morphology. In some cases, the temperature was also used to thermally crosslink the material [34]. However, the C-ES process must be conducted in controlled temperatures, so that the cells are not damaged. Therefore, temperature must be carefully regulated during this process. Humidity is another critical factor affecting fiber formation. A high humidity results in beaded fibers, because it enables the initial jet to elongate longer [35]. When the initial jet is longer, the charge on the surface of the jet declines due to an increased surface area, and this phenomenon leads to an unstable jet, causing capillary instability. When electrospinning is conducted under high humidity conditions, the beads are formed in between the thin fiber segments [35,36]. Therefore, to achieve C-ES, the cell-embedded solution must be precisely electrospun under the appropriate room humidity to fabricate bead-free fibers.

3. Biomaterials for Cell Electrospinning

In general, biomaterials are classified into two groups: naturally and synthetically derived polymers (Table 1). For achieving micro/nanofibers, synthetic polymers have been widely used in ES by selecting the appropriate solvents that can deliver the required viscosity, surface tension, and conductivity [37]. Owing to their high processability, many synthetic polymers, such as polymethylmethacrylate, polycaprolactone (PCL), and polylactic acid, were developed into fibrous structures through ES. However, the solvents used for ES—tetrahydrofuran, acetone, and chloroform—are usually toxic to cells. Even though removing these toxic solvents is necessary for cell culture, it is not appropriate for achieving biofabrication using living cells. Nam et al. demonstrated that solvent retention in the electrospun scaffolds composed of PCL, gelatin, and PCL-gelatin blend [38]. Canbolat et al. also showed that the residual solvent in the electrospun scaffolds affected the cell viability, and cleansing of the scaffolds only improved the cell viability by 5–10% [39]. Therefore, natural polymers are used in the C-ES process, owing to their cell-friendliness. Various natural polymers, such as alginate, collagen, and cellulose, are utilized for ES. Although these are biocompatible and hydrophilic, they reveal some drawbacks in electrospinnability, due to weak molecular chain entanglement or a repulsive force among ions [40,41]. To overcome these limitations, the C-ES process employs a core–shell nozzle or a mixture of synthetic and natural polymers. Table 2 lists the advantages and disadvantages of ES and C-ES processes.

3.1. Synthetic Polymers

Two of the synthetic polymers used in C-ES are poly(dimethylsiloxane) (PDMS) and polyvinyl alcohol (PVA) [18]. One of the very first C-ES processes used PDMS to encapsulate the cells in the fibers [18]. The PDMS was fed through to the outer needle at a 10−8 m3/s flow rate, which was utilized to provide mechanical strength. Meanwhile, the cell-laden biosuspension was fed through to the inner needle at 10−8 m3/s, and the finest cell-laden thread was fabricated using a 0.09 kV/mm electric field. The measured astrocytoma cell viability (67.6 ± 1.9%) was similar to the control astrocytoma cells (70.6 ± 5.0%) on a 2D culture plate. In another study, adipose stem cells (ASCs) were embedded in the microthreads composed of PVA [22]. This study will be discussed thoroughly later in this review.

3.2. Natural Polymers

Naturally derived biomaterials have shown many advantages over synthetic polymers as a material for bioink. Natural polymers provide bioactive cues which promote cellular functions. So, few natural polymers or blends of them have been used in order to replace synthetic materials. For instance, alginate with a poly(ethylene oxide) (PEO) and lecithin blend was used for bone regeneration. MG63, osteoblast-like cells, were used for this process. [21]. As a result, an electric field strength of 0.16 kV/mm showed the greatest cell viability of over 80%, with fibers ranging from 5 to 17 μm. Similarly, Yeo et al. also used alginate as the bioink material, together with PEO and CaCl2, as the crosslinker for skeletal muscle regeneration [30]. Here, the optimized electric field was 0.075 kV/mm and the cell (C2C12) viability was greater than 90%. As another C-ES material, a modified, Matrigel-rich collagen biopolymer was used for a different muscle tissue regeneration. Primary cardiomyocytes contained in the collagen-based bioink were electrospun by applying a voltage of 230 V and current of 50 mA [30]. No significant alterations were observed in the cell viability or function of the myocytes after the C-ES process. Gelatin, which is a collagen derivative, is also widely used in the tissue engineering field, since it has similar properties to collagen: great biodegradability and biocompatibility. However, its poor fiber-forming ability restricts its use in C-ES [56].

4. Application in Regenerative Medicine Using Different Cells

Since various tissues require tailored micro-/nano-environments for tissue regeneration, C-ES has been applied using various biomaterials and different strategies to build cell-laden fibers (Table 3). Briefly, in this section, the attempts at regenerating different types of tissues using C-ES will be introduced.

4.1. Bone Cells

As bone defects, such as infections, osteonecrosis, and cartilage problems, have been increasing, the importance of bone tissue regeneration has been increasing. As autologous bone graft demonstrates some limitations in terms of donor site morbidity and graft volume, allogenic bone regeneration medicine has received considerable attention. Even though 3D printing has been widely used to fabricate bone regenerative scaffold, it does not guarantee a high surface-area-volume ratio and high resolution, which can enable the fabrication of an ECM-like structure. Yeo et al. combined 3D printing and C-ES to complement a 3D structure with high mechanical strength and an ECM-like structure for bone regeneration [21]. MG63 human osteosarcoma cells (2 × 105 cells/mL) were encapsulated in alginate/PEO/lecithin solution and electrospun with a 0.16–kV/mm electric field and a 0.5–mL/h flow rate (Figure 2). The electrospun cells revealed a cell viability of over 80%, and their osteogenic differentiation was confirmed using alkaline phosphatase staining after 10 days of culture. Consequently, it could be established that C-ES enhanced bone regeneration by supplementing 3D printing with hierarchically designed, 3D cell-laden micro/nanofibrous structures.

4.2. Muscle Cells

Human muscle plays a prominent role in the whole body, as it comprises 45% of body mass and regulates stability and metabolism. The muscle tissue is made up of muscle cells which can be divided into three types: cardiac, skeletal, and smooth [63,64,65]. In a study by Ehler et al., primary neonatal rat cardiomyocytes were used to fabricate 3D cardiac patches for repairing ageing and/or damaged cardiac tissues [57]. The myocytes-laden Matrigel-rich collagen biopolymer was electrospun with a 3.6 mL/h flow rate and a 0.4 –kV/mm electric field (Figure 3a). The cell viability after C-ES was similar to that of the cells on the culture dish, which was approximately 80%. Then, the immunofluorescence staining of myosin binding protein C, sarcomeric α-actinin, connexin-43, and myosin revealed that C-ES supported the integrity of cardiac myocytes. The skeletal muscles demonstrate a long multinucleated structure and tissue layers arranged in parallel [66,67]. Aligned physical/biochemical cues have been generally known to accelerate muscle regeneration. In this regard, the aligned cell-laden micro/nanofibrous structure was assessed to observe cellular activities in comparison with 3D cell-printed structure [30]. The same bioink, alginate/PEO embedded with C2C12 cells (mouse myoblast cell line) (5 × 106 cells/mL), was used for both the C-ES and cell printing processes. For C-ES, an electric field of 0.075 –kV/mm strength, and a flow rate of 0.25 mL/h, were employed (Figure 3b). Cell morphology was captured at day 7, and it was observed that the cells on the micro/nanofibers aligned and elongated 3-fold compared with those on the printed structure. In addition, the formation of myosin heavy chains and sarcomeric α-actinin was significantly increased for the C-ES scaffold (Figure 3b). In short, muscle tissue engineering using C-ES illustrates not only compatibility with diverse types of muscle cells, but also controllability in micro-/nano-topological cues.

4.3. Other Cells

Townsend-Nicholson et al. developed a C-ES process with a coaxial nozzle to dispense cell-laden media in core and poly(dimethyl siloxane) (PDMS) in shells [18]. 1321N1-immortalized human astrocytes (1 × 106 cells/mL) were suspended in media and electrospun using a 0.36-mL/h flow rate and a 0.09-kV/mm electric field (Figure 4a). The cell viability was 67.6 ± 1.9% and 70.6% ± 5.0% for the electrospun 1321N1 cells and the control cells cultured in a Petri dish, respectively. The electrospun cells were as viable as the control cells, and these results correspond to the typical 1321N1 cell viability (65~75%). The electrospun cells proliferated through 9 days of culture, which demonstrates that 1321N1 cells were capable of maintaining metabolic activities after C-ES. Furthermore, mouse neuroblastoma N2A cells (5 × 105 cells/mL) were examined to compare control (2D culturing) and two experimental groups (C-ES and aerodynamically-assisted bio-threading (AABT)) [20]. To encapsulate N2A cells, a modified matrigel with a high concentration of laminin was used for both C-ES and AABT (Figure 4b). The C-ES scaffold revealed a cell viability from 60% to 85% throughout days 1 to 3, in which the result was similar to the AABT scaffold (Figure 4b). For in vivo tests in mice, the proliferation rate among the three groups was also similar, which reveals the adequate biocompatibility of C-ES.

4.4. Stem Cells

Stem cells are generally more vulnerable to external stimuli, and therefore, the fabrication of viable ECM-like microenvironments is essential for regenerating tissues using stem cells. To elaborate, Chen et al. developed a bioactive membrane through C-ES using ASCs [22]. In the work, they used 8.8% PVA (Mw = 2000) mixed with ASCs (1 × 107 cells/mL). Then, the electrospinning solution was flowed at 9.6-mL/h and applied with 0.8-kV/mm. The cellular activities of ASCs on electrospun fibers were assessed using the ASCs on a cell culture dish. After 28 days of cell culture, the ASCs on electrospun fibers managed to survive and proliferate by 133%, while those on the culture dish decreased by 18% from day 1 (Figure 5). This experiment established that ASCs were compatible with C-ES and a fibrous architecture was preferred to sustain cellular activities.

5. Concluding Remarks

5.1. Advantages of C-ES

Cell-electrospinning has been widely used not only in the bio-engineering field, but also in various other fields of study. This technology enables the fabrication of nanoscale fibers using a simple process. In contrast to other methodologies (e.g., cell-printing) that demonstrate limitations in fabricating micro-sized fibers, C-ES produces nano-sized cell-electrospun fibers that provide higher resolutions and better ECM-like structures. In addition, the cell-electrospun fibers demonstrate the synergistic effect of nanoscale patterning by guiding cells along the fibers, rather than just simulating the size of the structure. Also, the cell-electrospun fibers in nanoscale enable an efficient and fast exchange of nutrients and oxygen. Finally, the cell-electrospun fibers provide better cell-to-cell interaction than the cell-embedded bulk structure. Overall, we anticipate that C-ES can be used for a wide range of clinical applications in the area of regenerative medicine.

5.2. Limitations of C-ES

Although C-ES has been recognized as a leading biotechnology, it demonstrates some limitations. As the process of C-ES uses hydrogels to encapsulate cells in the fibers, the mechanical strength of the resulting structure may be low. Furthermore, the restrictions encountered by C-ES, with respect to the development of 3D structures, are still not addressed, which is also a limitation encountered in the conventional ES process. Another downside of C-ES is the low controllability in terms of cell density compared to 3D cell-printing techniques. Furthermore, achieving fiber deposition on precise location is challenging due to the whipping phenomenon that occurs during the generation of fibers.

5.3. Future Perspectives

C-ES, which is an emerging biomedical technique, was elaborated upon in this study, and its applications, advantages, and limitations were discussed. The capabilities of C-ES include embedding the living cells directly in nanoscale fibers and guiding the cells to grow in the fiber direction. These characteristics enable cellular activities, by providing physical cues and enlarging cell-to-cell/matrix interactions. However, several challenges still remain. Therefore, further studies are required to improve the mechanical properties—as well as cell density—and overcome the restrictions with respect to the development into 3D structures. To overcome the limitations and enhance the mechanical properties and shape-ability, modified techniques, such as cell-electrospinning combined with 3D printing, have emerged. In addition, developing a cell-electrospun structure with biological functional factors has been challenging. Therefore, a platform for co-culturing, or multiple cell culturing, should be actualized to simulate the physiological functions of complex tissue (i.e., vascularized muscle structure or skin layers comprising multiple cell types such as keratinocytes and fibroblasts). If these drawbacks are addressed, cell-embedded electrospun nanofibers demonstrate significant potential in the application of tissue engineering scaffolds.

Author Contributions

Conceptualization: G.K.; writing—original draft preparation: J.H., M.Y., and G.H.Y.; writing—review and editing: J.H., M.Y., G.H.Y., and G.K.

Funding

This research was supported by a grant from the National Research Foundation of Korea, funded by the Ministry of Education, Science, and Technology (MEST) (grant no. NRF-2018R1A2B2005263), and supported by the National Research Foundation of Korea (NRF). Grant funded by the Ministry of Science and ICT for Bioinspired Innovation Technology Development Project (NRF-2018M3C1B7021997).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Langer, R. Perspectives and challenges in tissue engineering and regenerative medicine. Adv. Mater. 2009, 21, 3235–3236. [Google Scholar] [CrossRef]
  2. Tucker, N.; Stanger, J.J.; Staiger, M.P.; Razzaq, H.; Hofman, K. The history of the science and technology of electrospinning from 1600 to 1995. J. Eng. Fiber Fabr. 2012, 7, 155892501200702S10. [Google Scholar] [CrossRef] [Green Version]
  3. Mercante, L.A.; Scagion, V.P.; Migliorini, F.L.; Mattoso, L.H.; Correa, D.S. Electrospinning-based (bio) sensors for food and agricultural applications: A review. Trends Anal. Chem. 2017, 91, 91–103. [Google Scholar] [CrossRef]
  4. Nisha, M.; Singh, D.; Freesta Shiny, J.; Sasirekha, B. Design and Manufacture of Nanofibers Using Electrospinning Technique for Aerospace Application. Appl. Mech. Mater. 2016, 852, 72–78. [Google Scholar] [CrossRef]
  5. Dotti, F.; Varesano, A.; Montarsolo, A.; Aluigi, A.; Tonin, C.; Mazzuchetti, G. Electrospun porous mats for high efficiency filtration. J. Ind. Textil. 2007, 37, 151–162. [Google Scholar] [CrossRef]
  6. Mirjalili, M.; Zohoori, S. Review for application of electrospinning and electrospun nanofibers technology in textile industry. J. Nanostruct. Chem. 2016, 6, 207–213. [Google Scholar] [CrossRef] [Green Version]
  7. Pham, Q.P.; Sharma, U.; Mikos, A.G. Electrospinning of polymeric nanofibers for tissue engineering applications: A review. Tissue Eng. 2006, 12, 1197–1211. [Google Scholar] [CrossRef] [Green Version]
  8. Yarin, A.L.; Koombhongse, S.; Reneker, D.H. Bending instability in electrospinning of nanofibers. J. Appl. Phys. 2001, 89, 3018–3026. [Google Scholar] [CrossRef] [Green Version]
  9. Chronakis, I.S. Novel nanocomposites and nanoceramics based on polymer nanofibers using electrospinning process—A review. J. Mater. Process Technol. 2005, 167, 283–293. [Google Scholar] [CrossRef]
  10. Braghirolli, D.I.; Steffens, D.; Pranke, P. Electrospinning for regenerative medicine: A review of the main topics. Drug Discov. Today 2014, 19, 743–753. [Google Scholar] [CrossRef]
  11. Barker, T.H. The role of ECM proteins and protein fragments in guiding cell behavior in regenerative medicine. Biomaterials 2011, 32, 4211–4214. [Google Scholar] [CrossRef]
  12. Schlie-Wolter, S.; Ngezahayo, A.; Chichkov, B.N. The selective role of ECM components on cell adhesion, morphology, proliferation and communication in vitro. Exp. Cell Res. 2013, 319, 1553–1561. [Google Scholar] [CrossRef]
  13. Alenghat, F.J.; Ingber, D.E. Mechanotransduction: All signals point to cytoskeleton, matrix, and integrins. Sci. Signal. 2002, 2002, pe6. [Google Scholar] [CrossRef]
  14. Chong, E.J.; Phan, T.T.; Lim, I.J.; Zhang, Y.; Bay, B.H.; Ramakrishna, S.; Lim, C.T. Evaluation of electrospun PCL/gelatin nanofibrous scaffold for wound healing and layered dermal reconstitution. Acta Biomater. 2007, 3, 321–330. [Google Scholar] [CrossRef]
  15. Yin, A.; Zhang, K.; McClure, M.J.; Huang, C.; Wu, J.; Fang, J.; Mo, X.; Bowlin, G.L.; Al-Deyab, S.S.; El-Newehy, M. Electrospinning collagen/chitosan/poly (L-lactic acid-co-ϵ-caprolactone) to form a vascular graft: Mechanical and biological characterization. J. Biomed. Mater. Res. A 2013, 101, 1292–1301. [Google Scholar] [CrossRef]
  16. Aviss, K.; Gough, J.; Downes, S. Aligned electrospun polymer fibres for skeletal muscle regeneration. Eur. Cell Mater. 2010, 19, 193–204. [Google Scholar] [CrossRef]
  17. Chew, S.Y.; Mi, R.; Hoke, A.; Leong, K.W. The effect of the alignment of electrospun fibrous scaffolds on Schwann cell maturation. Biomaterials 2008, 29, 653–661. [Google Scholar] [CrossRef] [Green Version]
  18. Townsend-Nicholson, A.; Jayasinghe, S.N. Cell electrospinning: A unique biotechnique for encapsulating living organisms for generating active biological microthreads/scaffolds. Biomacromolecules 2006, 7, 3364–3369. [Google Scholar] [CrossRef]
  19. Jayasinghe, S.N. Cell electrospinning: A novel tool for functionalising fibres, scaffolds and membranes with living cells and other advanced materials for regenerative biology and medicine. Analyst 2013, 138, 2215–2223. [Google Scholar] [CrossRef]
  20. Sampson, S.L.; Saraiva, L.; Gustafsson, K.; Jayasinghe, S.N.; Robertson, B.D. Cell electrospinning: An in vitro and in vivo study. Small 2014, 10, 78–82. [Google Scholar] [CrossRef] [Green Version]
  21. Yeo, M.; Kim, G. Fabrication of cell-laden electrospun hybrid scaffolds of alginate-based bioink and PCL microstructures for tissue regeneration. Chem. Eng. J. 2015, 275, 27–35. [Google Scholar] [CrossRef]
  22. Chen, H.; Liu, Y.; Hu, Q. A novel bioactive membrane by cell electrospinning. Exp. Cell Res. 2015, 338, 261–266. [Google Scholar] [CrossRef] [PubMed]
  23. Williams, D.; Thayer, P.; Martinez, H.; Gatenholm, E.; Khademhosseini, A. A perspective on the physical, mechanical and biological specifications of bioinks and the development of functional tissues in 3D bioprinting. Bioprinting 2018, 9, 19–36. [Google Scholar] [CrossRef]
  24. Gopinathan, J.; Noh, I. Recent trends in bioinks for 3D printing. Biomater. Res. 2018, 22, 11. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Kim, Y.B.; Lee, H.; Kim, G.H. Strategy to achieve highly porous/biocompatible macroscale cell blocks, using a collagen/genipin-bioink and an optimal 3D printing process. ACS Appl. Mater. Interfaces 2016, 8, 32230–32240. [Google Scholar] [CrossRef]
  26. Xue, J.; Wu, T.; Dai, Y.; Xia, Y. Electrospinning and electrospun nanofibers: Methods, materials, and applications. Chem. Rev. 2019, 119, 5298–5415. [Google Scholar] [CrossRef]
  27. Huang, Z.-M.; Zhang, Y.-Z.; Kotaki, M.; Ramakrishna, S. A review on polymer nanofibers by electrospinning and their applications in nanocomposites. Compos. Sci. Technol. 2003, 63, 2223–2253. [Google Scholar] [CrossRef]
  28. Lee, K.; Kim, H.; Khil, M.; Ra, Y.; Lee, D. Characterization of nano-structured poly (ε-caprolactone) nonwoven mats via electrospinning. Polymer 2003, 44, 1287–1294. [Google Scholar] [CrossRef]
  29. Dalton, P.D.; Lleixà Calvet, J.; Mourran, A.; Klee, D.; Möller, M. Melt electrospinning of poly-(ethylene glycol-block-ϵ-caprolactone). Biotechnol. J. 2006, 1, 998–1006. [Google Scholar] [CrossRef]
  30. Yeo, M.; Kim, G.H. Anisotropically Aligned Cell-Laden Nanofibrous Bundle Fabricated via Cell Electrospinning to Regenerate Skeletal Muscle Tissue. Small 2018, 14, 1803491. [Google Scholar] [CrossRef]
  31. Reneker, D.H.; Yarin, A.L.; Fong, H.; Koombhongse, S. Bending instability of electrically charged liquid jets of polymer solutions in electrospinning. J. Appl. Phys. 2000, 87, 4531–4547. [Google Scholar] [CrossRef] [Green Version]
  32. Zhao, Y.; Li, Y.; Mao, S.; Sun, W.; Yao, R. The influence of printing parameters on cell survival rate and printability in microextrusion-based 3D cell printing technology. Biofabrication 2015, 7, 045002. [Google Scholar] [CrossRef] [PubMed]
  33. Ouyang, L.; Yao, R.; Zhao, Y.; Sun, W. Effect of bioink properties on printability and cell viability for 3D bioplotting of embryonic stem cells. Biofabrication 2016, 8, 035020. [Google Scholar] [CrossRef] [PubMed]
  34. Ding, B.; Kim, H.-Y.; Lee, S.-C.; Lee, D.-R.; Choi, K.-J. Preparation and characterization of nanoscaled poly (vinyl alcohol) fibers via electrospinning. Fiber Polym. 2002, 3, 73–79. [Google Scholar] [CrossRef]
  35. Tripatanasuwan, S.; Zhong, Z.; Reneker, D.H. Effect of evaporation and solidification of the charged jet in electrospinning of poly (ethylene oxide) aqueous solution. Polymer 2007, 48, 5742–5746. [Google Scholar] [CrossRef]
  36. Bonino, C.A.; Efimenko, K.; Jeong, S.I.; Krebs, M.D.; Alsberg, E.; Khan, S.A. Three-dimensional electrospun alginate nanofiber mats via tailored charge repulsions. Small 2012, 8, 1928–1936. [Google Scholar] [CrossRef]
  37. Ahmed, F.E.; Lalia, B.S.; Hashaikeh, R. A review on electrospinning for membrane fabrication: Challenges and applications. Desalination 2015, 356, 15–30. [Google Scholar] [CrossRef]
  38. Nam, J.; Huang, Y.; Agarwal, S.; Lannutti, J. Materials selection and residual solvent retention in biodegradable electrospun fibers. J. Appl. Polym. Sci. 2008, 107, 1547–1554. [Google Scholar] [CrossRef]
  39. Fatih Canbolat, M.; Tang, C.; Bernacki, S.H.; Pourdeyhimi, B.; Khan, S. Mammalian cell viability in electrospun composite nanofiber structures. Macromol. Biosci. 2011, 11, 1346–1356. [Google Scholar] [CrossRef]
  40. Lu, J.-W.; Zhu, Y.-L.; Guo, Z.-X.; Hu, P.; Yu, J. Electrospinning of sodium alginate with poly (ethylene oxide). Polymer 2006, 47, 8026–8031. [Google Scholar] [CrossRef]
  41. Khorshidi, S.; Solouk, A.; Mirzadeh, H.; Mazinani, S.; Lagaron, J.M.; Sharifi, S.; Ramakrishna, S. A review of key challenges of electrospun scaffolds for tissue-engineering applications. J. Tissue Eng. Regen. Med. 2016, 10, 715–738. [Google Scholar] [CrossRef] [PubMed]
  42. Ferreira, A.M.; Gentile, P.; Chiono, V.; Ciardelli, G. Collagen for bone tissue regeneration. Acta Biomater. 2012, 8, 3191–3200. [Google Scholar] [CrossRef]
  43. Di Lullo, G.A.; Sweeney, S.M.; Körkkö, J.; Ala-Kokko, L.; San Antonio, J.D. Mapping the ligand-binding sites and disease-associated mutations on the most abundant protein in the human, type I collagen. J. Biol. Chem. 2002, 277, 4223–4231. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Dong, C.; Lv, Y. Application of collagen scaffold in tissue engineering: Recent advances and new perspectives. Polymers 2016, 8, 42. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  45. Veis, A. The Macromolecular Chemistry of Gelatin; Academic Press: New York, NY, USA, 1964. [Google Scholar]
  46. Ross-Murphy, S.B. Structure and rheology of gelatin gels: Recent progress. Polymer 1992, 33, 2622–2627. [Google Scholar] [CrossRef]
  47. Rowley, J.A.; Madlambayan, G.; Mooney, D.J. Alginate hydrogels as synthetic extracellular matrix materials. Biomaterials 1999, 20, 45–53. [Google Scholar] [CrossRef]
  48. Caliari, S.R.; Burdick, J.A. A practical guide to hydrogels for cell culture. Nat. Methods 2016, 13, 405. [Google Scholar] [CrossRef] [Green Version]
  49. Lee, K.Y.; Mooney, D.J. Alginate: Properties and biomedical applications. Prog. Polym. Sci. 2012, 37, 106–126. [Google Scholar] [CrossRef] [Green Version]
  50. McDonald, J.C.; Whitesides, G.M. Poly (dimethylsiloxane) as a material for fabricating microfluidic devices. Acc. Chem. Res. 2002, 35, 491–499. [Google Scholar] [CrossRef]
  51. Ghannam, M.T.; Esmail, M.N. Rheological properties of poly (dimethylsiloxane). Ind. Eng. Chem. Res. 1998, 37, 1335–1340. [Google Scholar] [CrossRef]
  52. Mata, A.; Fleischman, A.J.; Roy, S. Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems. Biomed. Microdevices 2005, 7, 281–293. [Google Scholar] [CrossRef] [PubMed]
  53. Baker, M.I.; Walsh, S.P.; Schwartz, Z.; Boyan, B.D. A review of polyvinyl alcohol and its uses in cartilage and orthopedic applications. J. Biomed. Mater. Res. B 2012, 100, 1451–1457. [Google Scholar] [CrossRef] [PubMed]
  54. Aleyamma, A.; Sharma, C. Polyvinyl Alcohol as a Biomateria; Technomic Publishing Company: Lancaster, PA, USA, 1990; p. 123. [Google Scholar]
  55. Moscato, S.; Mattii, L.; D’Alessandro, D.; Cascone, M.G.; Lazzeri, L.; Serino, L.P.; Dolfi, A.; Bernardini, N. Interaction of human gingival fibroblasts with PVA/gelatine sponges. Micron 2008, 39, 569–579. [Google Scholar] [CrossRef] [PubMed]
  56. Yang, C.Y.; Chiu, C.T.; Chang, Y.P.; Wang, Y.J. Fabrication of porous gelatin microfibers using an aqueous wet spinning process. Artif. Cell Blood Sub. 2009, 37, 173–176. [Google Scholar] [CrossRef] [PubMed]
  57. Ehler, E.; Jayasinghe, S.N. Cell electrospinning cardiac patches for tissue engineering the heart. Analyst 2014, 139, 4449–4452. [Google Scholar] [CrossRef] [PubMed]
  58. Guo, Y.; Gilbert-Honick, J.; Somers, S.M.; Mao, H.-Q.; Grayson, W.L. Modified cell-electrospinning for 3D myogenesis of C2C12s in aligned fibrin microfiber bundles. Biochem. Biophys. Res. Commun. 2019, 516, 558–564. [Google Scholar] [CrossRef] [PubMed]
  59. Jayasinghe, S.N.; Irvine, S.; McEwan, J.R. Cell electrospinning highly concentrated cellular suspensions containing primary living organisms into cell-bearing threads and scaffolds. Future Med. 2007, 2, 555–567. [Google Scholar] [CrossRef]
  60. Patel, P.; Irvine, S.; McEwan, J.R.; Jayasinghe, S.N. Bio-protocols for directly forming active encapsulations containing living primary cells. Soft Matter 2008, 4, 1219–1229. [Google Scholar] [CrossRef]
  61. Shih, Y.H.; Yang, J.C.; Li, S.H.; Yang, W.C.V.; Chen, C.C. Bio-electrospinning of poly (l-lactic acid) hollow fibrous membrane. Text. Res. J. 2012, 82, 602–612. [Google Scholar] [CrossRef]
  62. Jayasinghe, S.; Townsend-Nicholson, A. Stable electric-field driven cone-jetting of concentrated biosuspensions. Lab. Chip 2006, 6, 1086–1090. [Google Scholar] [CrossRef]
  63. Zimmermann, W.-H.; Didié, M.; Döker, S.; Melnychenko, I.; Naito, H.; Rogge, C.; Tiburcy, M.; Eschenhagen, T. Heart muscle engineering: An update on cardiac muscle replacement therapy. Cardiovasc. Res. 2006, 71, 419–429. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  64. Bach, A.; Beier, J.; Stern-Staeter, J.; Horch, R. Skeletal muscle tissue engineering. J. Cell Mol. Med. 2004, 8, 413–422. [Google Scholar] [CrossRef] [PubMed]
  65. Chamley-Campbell, J.; Campbell, G.R.; Ross, R. The smooth muscle cell in culture. Physiol. Rev. 1979, 59, 1–61. [Google Scholar] [CrossRef] [PubMed]
  66. Levenberg, S.; Rouwkema, J.; Macdonald, M.; Garfein, E.S.; Kohane, D.S.; Darland, D.C.; Marini, R.; Van Blitterswijk, C.A.; Mulligan, R.C.; D’Amore, P.A. Engineering vascularized skeletal muscle tissue. Nat. Biotechnol. 2005, 23, 879. [Google Scholar] [CrossRef]
  67. Charge, S.B.; Rudnicki, M.A. Cellular and molecular regulation of muscle regeneration. Physiol. Rev. 2004, 84, 209–238. [Google Scholar] [CrossRef]
Figure 1. (a) Electrospinning process with the basic components. (b) Extracellular matrix (ECM) structure and cell–cell interconnectivity on a flat, micro, and nano structure. (c) Cell-electrospinning process with the processing parameters.
Figure 1. (a) Electrospinning process with the basic components. (b) Extracellular matrix (ECM) structure and cell–cell interconnectivity on a flat, micro, and nano structure. (c) Cell-electrospinning process with the processing parameters.
Ijms 20 06208 g001
Figure 2. (a) Schematic and optical image for fabrication process. (b) SEM/fluorescence (live/dead) images of fabricated cell (MG63)-laden electrospun fibers. (c) Optical images of alkaline phosphatase (ALP) stained cells. Figure adapted with permission from [21]. Copyright 2015 Elsevier.
Figure 2. (a) Schematic and optical image for fabrication process. (b) SEM/fluorescence (live/dead) images of fabricated cell (MG63)-laden electrospun fibers. (c) Optical images of alkaline phosphatase (ALP) stained cells. Figure adapted with permission from [21]. Copyright 2015 Elsevier.
Ijms 20 06208 g002
Figure 3. (a) Optical images of the fabrication process for electrospun cardiac patch. Fluorescence images of GFP-labeled cardiac cells (left), MyBP-C/sarcomeric α-actin/F-actin stained cardiac cell (middle), and connexin-43/myomesin/nuclei stained cardiac cell (right). Figure adapted with permission from [57]. Copyright 2014 The Royal Society of Chemistry. (b) Schematic/optical/SEM images of electrospinning process for generating aligned micro/nanofibers. Optical/fluorescence images of electrospun C2C12 myoblast cells-laden micro/nanofibers. Figure adapted with permission from [30]. Copyright 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Figure 3. (a) Optical images of the fabrication process for electrospun cardiac patch. Fluorescence images of GFP-labeled cardiac cells (left), MyBP-C/sarcomeric α-actin/F-actin stained cardiac cell (middle), and connexin-43/myomesin/nuclei stained cardiac cell (right). Figure adapted with permission from [57]. Copyright 2014 The Royal Society of Chemistry. (b) Schematic/optical/SEM images of electrospinning process for generating aligned micro/nanofibers. Optical/fluorescence images of electrospun C2C12 myoblast cells-laden micro/nanofibers. Figure adapted with permission from [30]. Copyright 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ijms 20 06208 g003
Figure 4. (a) Optical/schematic image of the fabrication process for cell electrospinning using 1321N1 human astrocytes. Optical images of the 1321N1 cells cultured for 55 h (left), 80 h (middle), and 144 h (right). Figure adapted with permission from [18]. Copyright 2006 American Chemical Society. (b) Schematic/optical image of cell electrospinning using mouse neuroblastoma (N2A) cells. Optical images of electrospun N2A cells in situ and after 24 h, 48 h, and 72 h. Figure adapted with permission from [20]. Copyright 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Figure 4. (a) Optical/schematic image of the fabrication process for cell electrospinning using 1321N1 human astrocytes. Optical images of the 1321N1 cells cultured for 55 h (left), 80 h (middle), and 144 h (right). Figure adapted with permission from [18]. Copyright 2006 American Chemical Society. (b) Schematic/optical image of cell electrospinning using mouse neuroblastoma (N2A) cells. Optical images of electrospun N2A cells in situ and after 24 h, 48 h, and 72 h. Figure adapted with permission from [20]. Copyright 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ijms 20 06208 g004
Figure 5. (a) Optical images of electrospun adipose stem cells (ASCs). (b) SEM images of ASCs after 7 days and 28 days of culture. Figure adapted with permission from [22]. Copyright 2015 Elsevier.
Figure 5. (a) Optical images of electrospun adipose stem cells (ASCs). (b) SEM images of ASCs after 7 days and 28 days of culture. Figure adapted with permission from [22]. Copyright 2015 Elsevier.
Ijms 20 06208 g005
Table 1. Description of materials used for cell-electrospinning classified into natural and synthetic polymers.
Table 1. Description of materials used for cell-electrospinning classified into natural and synthetic polymers.
BiomaterialDescriptionAdvantagesDisadvantages
Natural polymerCollagen [42,43,44]Most abundant protein in mammals
Main protein of extracellular matrix (ECM)
Mostly found in tendons, ligaments, bone and skin tissue
Highly biocompatible and biodegradable
Relatively nonimmunogenic
Poor mechanical strength
Expensive
Gelatin [45,46]Derived from collagen
Similar properties with collagen
Biocompatible and biodegradable
Relatively low cost
Poor mechanical strength
Alginate [47,48,49]Derived from cell walls of brown algae
Natural polysaccharide
Biocompatible and biodegradable
Adequate crosslinking capacity
Relatively low cost
Non-toxicity
Poor mechanical strength without crosslinking
Low biological properties
Synthetic polymerPoly(dimethylsiloxane) (PDMS) [50,51,52]Silicon-based organic polymerNon-toxic and inert
Viscoelastic
Homogeneous and isotropic
Lacks in bio-functional cues
Polyvinyl alcohol (PVA)
[53,54,55]
Water-soluble synthetic polymer High solubility and biodegradability
Relatively low cost
Long-lasting durability
High temperature stability
Lacks in bio-functional cues
Table 2. Advantages and disadvantages of conventional electrospinning and cell-electrospinning.
Table 2. Advantages and disadvantages of conventional electrospinning and cell-electrospinning.
ElectrospinningCell-Electrospinning
AdvantagesSimple process
Provide controllable micro/nano-sized fibers
Mimic the native ECM structure
All the same advantages of electrospinning
High resolution (nanoscale)
Efficient and fast nutrients/oxygen exchange
Excellent cell-to-cell interaction
Homogeneous cell distribution in strut
DisadvantagesUse of toxic solvents
Insufficient cell infiltration
Inhomogeneous cell distribution
Low mechanical properties
Restrict to develop into 3D structure
Low cell density controllability
Low precision in fiber deposition
Table 3. Summary of various cells used in cell-electrospinning processes.
Table 3. Summary of various cells used in cell-electrospinning processes.
Cell TypesSolutionReference
Osteoblast (MG63) cellsAlginate/poly(ethylene oxide) (PEO)/lecithin[21]
Primary cardiomyocytesMatrigel rich collagen biopolymer[57]
C2C12 myoblast cellsAlginate/PEO [30]
C2C12 myoblast cellsFibrin/PEO[58]
Primary porcine vascular smooth muscle cells (SMCs) and rabbit aorta SMCsPoly(dimethyl siloxane) (PDMS)[59,60]
PC-12 cellsPoly(l-lactic acid)[61]
Human astrocytes (1321N1) PDMS[18,62]
Neuroblastoma (N2A) cellsMatrigel with high concentration of laminin[20]
Adipose stem cells (ASCs)Polyvinyl alcohol (PVA)[22]

Share and Cite

MDPI and ACS Style

Hong, J.; Yeo, M.; Yang, G.H.; Kim, G. Cell-Electrospinning and Its Application for Tissue Engineering. Int. J. Mol. Sci. 2019, 20, 6208. https://doi.org/10.3390/ijms20246208

AMA Style

Hong J, Yeo M, Yang GH, Kim G. Cell-Electrospinning and Its Application for Tissue Engineering. International Journal of Molecular Sciences. 2019; 20(24):6208. https://doi.org/10.3390/ijms20246208

Chicago/Turabian Style

Hong, Jiyoung, Miji Yeo, Gi Hoon Yang, and GeunHyung Kim. 2019. "Cell-Electrospinning and Its Application for Tissue Engineering" International Journal of Molecular Sciences 20, no. 24: 6208. https://doi.org/10.3390/ijms20246208

APA Style

Hong, J., Yeo, M., Yang, G. H., & Kim, G. (2019). Cell-Electrospinning and Its Application for Tissue Engineering. International Journal of Molecular Sciences, 20(24), 6208. https://doi.org/10.3390/ijms20246208

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop