Next Article in Journal
Anticancer and Immunomodulatory Benefits of Taro (Colocasia esculenta) Corms, an Underexploited Tuber Crop
Previous Article in Journal
Transcriptomic Changes of Murine Visceral Fat Exposed to Intermittent Hypoxia at Single Cell Resolution
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Influence of ClearT and ClearT2 Agitation Conditions in the Fluorescence Imaging of 3D Spheroids

by
Daniel N. Silva
1,
Elisabete C. Costa
1,
Carolina F. Rodrigues
1,
Duarte de Melo-Diogo
1,
Ilídio J. Correia
1,2,* and
André F. Moreira
1,*
1
CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, 6200-506 Covilhã, Portugal
2
CIEPQPF—Departamento de Engenharia Química, Universidade de Coimbra, Rua Sílvio Lima, Polo II, 3030-790 Coimbra, Portugal
*
Authors to whom correspondence should be addressed.
Int. J. Mol. Sci. 2021, 22(1), 266; https://doi.org/10.3390/ijms22010266
Submission received: 15 December 2020 / Revised: 25 December 2020 / Accepted: 26 December 2020 / Published: 29 December 2020
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)

Abstract

:
3D tumor spheroids have arisen in the last years as potent tools for the in vitro screening of novel anticancer therapeutics. Nevertheless, to increase the reproducibility and predictability of the data originated from the spheroids it is still necessary to develop or optimize the techniques used for spheroids’ physical and biomolecular characterization. Fluorescence microscopy, such as confocal laser scanning microscopy (CLSM), is a tool commonly used by researchers to characterize spheroids structure and the antitumoral effect of novel therapeutics. However, its application in spheroids’ analysis is hindered by the limited light penetration in thick samples. For this purpose, optical clearing solutions have been explored to increase the spheroids’ transparency by reducing the light scattering. In this study, the influence of agitation conditions (i.e., static, horizontal agitation, and rotatory agitation) on the ClearT and ClearT2 methods’ clearing efficacy and tumor spheroids’ imaging by CLSM was characterized. The obtained results demonstrate that the ClearT method results in the improved imaging of the spheroids interior, whereas the ClearT2 resulted in an increased propidium iodide mean fluorescence intensity as well as a higher signal depth in the Z-axis. Additionally, for both methods, the best clearing results were obtained for the spheroids treated under the rotatory agitation. In general, this work provides new insights on the ClearT and ClearT2 clearing methodologies and their utilization for improving the reproducibility of the data obtained through the CLSM, such as the analysis of the cell death in response to therapeutics administration.

Graphical Abstract

1. Introduction

For the past decades, two-dimensional (2D) cultures (monolayers of cells) of tumor cells have been the gold standard to develop and evaluate the effectiveness of anticancer therapeutic agents [1]. Although these 2D cell cultures are cheap and easy to reproduce, they fail to mimic the tumor tissues’ three-dimensional (3D) architecture, their mechanic and biochemical properties, as well as their cell-cell and cell-extracellular matrix (ECM) interactions [1,2]. Up to now, these cell culture models have led to poor predictions of the therapeutic effectiveness of new therapeutics in humans [3]. To overcome this situation, 3D cell cultures such as spheroids, have emerged as an alternative for drug screening, before the study proceeds to animal experimentation or to clinical trials in humans [4]. Spheroids are able to represent several properties of the solid tumors, in comparison to 2D cell cultures, such as: (i) distribution of proliferative, senescent and necrotic cells; (ii) distribution of nutrients and gases, that leads to the formation of hypoxic and acidic environments; (iii) cell-cell signaling; (iv) ECM deposition; (v) ECM-cell and cell-cell physical interactions; (v) growth kinetics; (vi) gene expression and (vii) drug resistance (reviewed in detail in [5]). Despite being a good replica of what happens in real cancerous tissue, there is a lack of well-established protocols and equipment adapted to spheroids’ analysis hindering the reproducibility and accuracy of the data originated from these models, i.e., most of the currently available methods are only optimized for the analysis of the therapeutics effectiveness on 2D cell cultures [2,6,7]. For instance, the imaging of spheroids by fluorescence microscopy is quite challenging, namely through confocal laser scanning microscopy (CLSM). This technique, which is one of the most common and widely available in the different laboratories worldwide, is used to analyze several features of the spheroids (e.g., size and morphology [8,9], proteins expression [10], cellular death [11], and therapeutics or nanoparticles penetration [12]). Nevertheless, since CLSM does not allow one to fully image samples with a thickness higher than 100–150 μm [13,14,15], it is impossible to analyze whole intact spheroids, which usually present diameters superior to 400 µm [16]. Although this problem can be overcome by sectioning the spheroid into thin slices of 5–7 µm, this procedure is very time-consuming, depend on organic solvent, and can also compromise the initial structure of the spheroid [13,17]. Therefore, optical clearing methods have been evaluated to improve the imaging of spheroids by CLSM [18,19,20,21,22]. These methods aim to improve the microscope’s signal penetration depth by increasing the spheroids transparency and improve the light penetration within the spheroid. For that purpose, the clearing solutions promote the homogenization of the refractive index (RI) through the spheroids and reduce the light scattering effect [15,23]. In the literature, several optical clearing methods have been used for improving the spheroids analysis, namely ClearT [19], ClearT2 [18,20,21], SeeDB [14,18], FocusClear [22], BABB [24,25,26,27], Scale [14,18], CUBIC [28], and CLARITY [29,30]. Among these, ClearT and ClearT2 methods are organic-solvent and detergent free, the solutions are easy to handle, and the protocols are not very time-consuming. In ClearT method, samples are cleared by immersing them in increasing concentrations of aqueous solutions of formamide. The ClearT2 method is performed by immersing the samples in aqueous solutions with increasing concentrations of formamide and polyethylene glycol (PEG). PEG is used to maintain the integrity and stability of the fluorescently-labeled elements (e.g., proteins), thus avoiding the fluorescence quenching prompted by the formamide [15,31,32,33]. Both protocols were described for the first time by Kuwajima et al. to clear mice tissues (e.g., whole brain and brain sections) [32].
In our group, we already demonstrated that ClearT and ClearT2 enhance the imaging of propidium iodide (PI)-stained spheroids via CLSM [19,21]. However, the influence of the ClearT and ClearT2 clearing solutions incubation conditions (e.g., static, horizontal agitation and rotatory agitation) on the spheroids clearing and imaging by CLSM is still poorly explored in the literature. In most of the studies, the spheroids are maintained under horizontal agitation during their incubation with the clearing solutions [18,21]. For instance, Boutin et al. performed the ClearT2 method using a shaker plate at 90 rotations per minute (RPM) [18]. In other studies, it is not described as the conditions used for the incubation of the ClearT and ClearT2 [32,34]. In this work, a direct comparison of the ClearT and ClearT2 methods clearing efficacy was performed taking also in account the influence of the solutions incubation conditions (static, horizontal agitation, and rotatory agitation) on the spheroids’ transparency and imaging by CLSM, to determine the best procedure to obtain improved images of PI-stained spheroids.

2. Materials and Methods

2.1. Materials

Normal human dermal fibroblasts (HFIB) were acquired from PromoCell (Labclinics, S.A., Barcelona, Spain). T-flasks, cell culture plates and other cell culture consumables were obtained from ThermoFisher Scientific (Porto, Portugal). Cell imaging plates were bought from Ibidi GmbH (Ibidi, Munich, Germany). Fetal bovine serum (FBS) was purchased from Biochrom AG (Berlin, Germany). PI was procured from Invitrogen (Carlsbad, CA, USA). Agarose was obtained from Grisp (Porto, Portugal). Dulbecco’s modified Eagle’s medium F12 (DMEM-F12), paraformaldehyde (PFA), phosphate-buffered saline (PBS), trypsin, formamide (≥99.5%), ethylenediaminetetraacetate (EDTA), and PEG 4000 Da were purchased from Sigma-Aldrich (Sintra, Portugal).

2.2. Methods

2.2.1. Cells Maintenance and 3D HFIB Formation

HFIB cells were cultured in 175 cm2 T-flasks with DMEM-F12 media supplemented with FBS (10% (v/v)) and gentamycin and streptomycin (1% (v/v)), inside an incubator with a humidified atmosphere at 37 °C and 5 % CO2 [35]. When cells achieved a confluent state, they were recovered by using 0.25 % trypsin (1:250) and EDTA 0.1% (w/v). The spheroids self-assembly on agarose structures with 81 spherical microwells was performed as previously described in our group [19,21]. In brief, an agarose solution (2% (w/v) in H2O) was placed on 3-D Petri Dish® templates (Microtissues Inc., Providence, RI, USA) to obtain the agarose structures. After, these structures were placed in 12-well cell culture plates and sterilized by ultraviolet (UV) radiation. Then, 1 × 106 HFIB cells were placed in each structure. During the spheroids’ growth, DMEM-F12 media containing 10% (v/v) of FBS and 1% (v/v) of streptomycin and gentamycin was added to each well and the plates were maintained inside an incubator with a humidified atmosphere (37 °C and 5% CO2). The medium was changed every two days.

2.2.2. HFIB Spheroids Fixation and Incubation with PI

After 6 days, spheroids were collected and subjected to a chemical fixation procedure. In brief, spheroids were immersed on 4% (w/v) PFA during 24 h at 4 °C [21]. After, spheroids were washed with PBS and labeled with PI (1 mL; 10 μg/mL in H2O). After 24 h of PI incubation at 4 °C, spheroids were washed three times with PBS to remove the excess of PI staining.

2.2.3. Spheroids Optical Clearing by ClearT

Spheroids that were previously stained with PI were cleared by using the ClearT solutions [19,32] (Figure 1). Briefly, different formamide solutions (20, 40, 80 and 95% (v/v) in PBS) were freshly prepared. Then, spheroids were serially incubated with 20, 40, 80 and 95% formamide solutions during 5 min each, and lastly with 95% formamide solution during 15 min. To assess the best conditions for spheroids’ clearing, spheroids were immersed in the clearing solutions under three different conditions: (i) static conditions where no agitation was used—ClearT/S; (ii) horizontal agitation at 200 RPM by using an orbital mixer (LBX MM1500 series, Labbox, Barcelona, Spain)—ClearT/H; and (iii) rotatory agitation using a tube roller shaker (MX-T6-S Analog Tube Roller, Scilogex, city, CT, USA) at 50 RPM—ClearT/R. All the methods were performed at room temperature (RT). After the clearing, spheroids were transferred to μ-slide 8 well imaging plates (Ibidi GmbH) to be imaged by CLSM (Section 2.2.6).

2.2.4. Spheroids Optical Clearing by ClearT2

PI-stained spheroids were cleared by using ClearT2 solutions [21,32]—Figure 1. Initially, 25% formamide/10% PEG 4000 Da and 50% formamide/20% PEG 4000 Da solutions were freshly prepared, as previously described in detail by Kuwajima [32]. Then, spheroids were incubated with 25% formamide/10% PEG solution during 10 min, 50% formamide/20% PEG for 5 min and lastly 50% formamide/20% PEG for 1 h. During the clearing procedure, three different conditions were tested, as described in Section 2.2.3 for the ClearT method: (i) ClearT2/S; (ii) ClearT2/H; and (iii) ClearT2/R. All methods were performed at RT. After the clearing, spheroids were transferred to μ-slide 8 well imaging plates (Ibidi GmbH) to be imaged via CLSM (Section 2.2.6).

2.2.5. Spheroids Imaging and Analysis by Optical Microscopy

To observe any possible variation in HFIB spheroids transparency and size after each optical clearing protocol is performed, optical microscopy images of the spheroids were acquired using a CX41 inverted optical microscope (Olympus, Hamburg, Germany) equipped with an Olympus SP-500 UZ digital camera and an Axio Imager A1 inverted microscope (Carl Zeiss, SMT, Inc., Oberkochen, Germany) equipped with an AxioVision camera. The transparency was checked by placing the spheroids on a crosshatched background, as previously described elsewhere [18,19,21,32]. The influence of the optical clearing methods on the size of the spheroids was determined by measuring their diameter before and after the clearing procedure. For this analysis, the optical microscopy images were analyzed by using an image processing program designed for scientific purposes—ImageJ (National Institutes of Health, Bethesda, MD, USA) [36], as previously described in detail [35].

2.2.6. Spheroids Imaging and Analysis by CLSM

HFIB spheroids were imaged by CLSM using a Zeiss LSM 710 AxioObserver laser scanning confocal microscope. For comparative purposes, all the samples were analyzed using the same equipment settings. The objective used was a 10× air objective (EC Plan-Neofluar 10×/0.30 M27). The size of the confocal aperture was 1 Airy disk, and z-stacks were collected with 5 μm intervals. Laser power and master gain were kept constant during image acquisition. PI was visualized by using 514 nm argon laser and the emission wavelengths range was 566–719 nm.
The images obtained through CLSM were then analyzed by using ImageJ (National Institutes of Health [36]), to determine the PI fluorescence levels, imaging depth of the PI in the Z-axis and PI cross-section imaging depth. The PI fluorescence levels were obtained by calculating the corrected total cell fluorescence (CTCF) [14,37,38]. For this purpose, the integrated density (ID), the spheroids area (A) and mean fluorescence of the background (MFB) values of the CLSM maximum intensity z-projections with a thickness of 100 µm (total of 20 Z-stacks) were determined and then used in the Equation (1) [19,21,37]:
CTCF = ID A   ×   MFB
The imaging penetration depth of the PI, i.e., how deep in the Z-axis it is possible to acquire PI fluorescence signal (please see Figure 4A), was calculated by multiplying the number of stacks with PI fluorescence (stacks with fluorescence intensity in the spheroids area higher than the fluorescence intensity of the background) by the thickness of the stack (5 µm) [39,40]. Lastly, to determine the PI cross-section imaging depth that translates the PI fluorescence inside the spheroid, it was counted the number of pixels with fluorescence in the spheroid area at 25, 50, 75 and 100 µm of depth in the Z-axis (please see Figure 4D) [41,42]. To accomplish that, the gray value of each pixel in the spheroid area was determined (gray value equal to zero corresponds to pixels with no PI fluorescence; gray value higher than 0 corresponds to pixels with PI fluorescence) [41,42].
The obtained values were compared and normalized to the average of those obtained for non-cleared spheroids, i.e., maintained in PBS.

2.2.7. Statistical Analysis

The data obtained were expressed as mean value ± standard deviation (S.D.). The statistical analysis was performed using one-way analysis of variance (ANOVA) test. A value of p < 0.05 was considered statistically significant. Data analysis was performed in GraphPad Prism v.6.0 software (trial version, GraphPad Software, San Diego, CA, USA).

3. Results and Discussion

The optical clearing methods have allowed the obtention of fluorescence microscopy images of 3D cell cultures with better quality and resolution. Nevertheless, these methods were initially developed to be applied in tissues or organs gathered from animals and very few have been optimized for the imaging of spheroids. ClearT and ClearT2 methods have been already used to clear spheroids in several works [18,19,20,21], although these methods are not yet fully optimized for this purpose. In a previous study performed by our group, we investigated the influence of PEG molecular weight (4000, 8000 and 10,000 Da) on the spheroids clearing efficacy of the ClearT2 method [21]. Such study demonstrated that the utilization of PEG 4000 Da, instead of the conventional PEG 8000 Da, allows better imaging of spheroids, since it was possible to obtain higher PI mean fluorescence intensity as well as an increased signal penetration in the Z-axis and fluorescence signal in the interior of the spheroids [21]. Herein, we further optimized both ClearT and ClearT2 methods taking into consideration the conditions of incubation of the clearing solutions (Figure 1). For that purpose, PI-stained HFIB spheroids were cleared by using aqueous solutions of formamide (ClearT) and formamide:PEG 4000 Da (ClearT2) and incubation under different conditions, namely: (i) static; (ii) horizontal agitation using an orbital mixer; and (iii) rotatory agitation using a roller shaker. After the clearing and imaging by CLSM, the spheroids’ size, transparency, PI fluorescence intensity, PI imaging depth in the Z-axis and PI cross-section imaging were analyzed to determine the best approach to perform the ClearT and ClearT2 methods.

3.1. Spheroids’ Size

The variations on spheroids’ size are one of the major concerns associated with the use of the optical clearing methods since it means that the methods affect the sample initial structure and morphology [15,38]. In some optical clearing methods, organic solvents like methanol are used for promoting samples dehydration (e.g., Spalteholz’s technique, BABB and 3DISCO), and these solvents induce spheroids shrinkage [43]. Likewise, methods that include hydration steps using urea (e.g., Scale and CUBIC) usually induce spheroids swelling [31]. Theoretically, ClearT and ClearT2 methods may also increase the volume of the samples, since these methods include the intake of an aqueous clearing solution into the sample by osmotic pressure [15]. Nevertheless, in previous studies, it was demonstrated that ClearT and ClearT2 methods do not induce significative changes in the size of animal samples (e.g., mouse brains) [32] or spheroids [18,19,21]. Similarly, in this study, it was also observed that the spheroids’ size is not affected by the incubation conditions of the solutions used in the ClearT and ClearT2 methods (Figure 2 and Table 1). Before the clearing process, spheroids exhibited mean diameters of 399.04 ± 39.26 µm. After the performance of the ClearT method under static, horizontal agitation and rotatory agitation conditions, the mean diameter of the spheroids was 473.23 ± 63.24, 469.90 ± 83.18 and 447.21 ± 13.71 µm, respectively (Figure 2A). Similar results were obtained for the ClearT2 method, i.e., the spheroids’ mean diameter was 478.91 ± 67.10, 464.77 ± 42.24 and 474.91 ± 33.43 µm after using static, horizontal agitation or rotatory agitation conditions, respectively (Figure 2B). These results demonstrate that the agitation conditions used for the incubation of the formamide-based solutions will not influence spheroids structure, and therefore it will not lead to incorrect interpretations [15,38].

3.2. Spheroids’ Transparency

Optical microscopy images of the spheroids placed on a crosshatched background were acquired to observe if the agitation conditions affect the ClearT and ClearT2 methods capacity to render transparency to the spheroids [18,19,21,32]. As it is possible to observe in Figure 2C, independently of the incubation condition of the different formamide-based solutions, all the cleared spheroids become more transparent when compared to the non-cleared ones. Notwithstanding, it is possible to witness that the utilization of rotatory agitation during the spheroids immersion in the clearing solutions, i.e., ClearT/R and ClearT2/R methods, resulted in the greatest spheroids transparency (Figure 2C).

3.3. PI Fluorescence

It is important to ensure that the optical clearing methods do not impact the fluorescence intensity, e.g., quenching. Preservation of the fluorescence will allow the imaging of the sample through fluorescence microscopy and the correct analysis of the labeled proteins and cellular structures [19]. Methods that include dehydration steps (e.g., BABB and 3DISCO) usually alter the fluorescence of proteins, since protein-based fluorescent chromophores need water molecules to sustain their fluorescence emission [15]. Additionally, these methods use organic solvents to clear the samples that can induce structural changes on the fluorescence labelled proteins disrupting their fluorescence [15,44]. Otherwise, it is also known that the formamide used in ClearT and ClearT2 can mediate the denaturation of proteins leading to the fluorescence quenching, as previously demonstrated using in vivo samples stained with the green fluorescent protein (GFP) [32]. With this in mind, ClearT2 method uses PEG simultaneously with formamide to stabilize the proteins, avoiding the formamide-mediated quenching of the protein dyes fluorescence [32,38].
Considering that the incubation conditions of the ClearT and ClearT2 clearing solutions resulted in different levels of spheroids transparency, it was also evaluated if the PI fluorescence intensity is influenced by the samples agitation. Therefore, the PI fluorescence intensity of maximum projections (100 µm) CLSM images of non-cleared and spheroids cleared by ClearT and ClearT2 under different conditions were measured and are presented in Figure 3. The obtained images show that the ClearT/S and ClearT/H did not lead to the loss of PI-fluorescence, while the ClearT/R method reduced the PI fluorescence significantly to 59.26 ± 10.39% (Figure 3A,C). Such results can be attributed to the DNA denaturation [45] and the quenching of fluorescent dyes [46] by the formamide. Therefore, the reduction on the PI fluorescence on ClearT/R may show that the rotatory agitation increases the amount of formamide that interact with the spheroids when compared to the static and horizontal agitation conditions. Otherwise, the spheroids cleared using the ClearT2/H and ClearT2/R methods showed a higher PI fluorescence intensity, 152.11 ± 33.48% and 187 ± 64.25%, respectively (Figure 3B,C). Such can be attributed to the increased interaction of ClearT2 solutions with the spheroids under agitation conditions, favoring the stabilization of the PI/DNA staining by PEG as previously reported in the literature [21]. Furthermore, considering that formamide:PEG solutions do not have absorbance in 400–800 nm range, possible autofluorescence phenomena of these solutions should be disregarded, as previously showed elsewhere [21,47,48].

3.4. PI Fluorescence Depth in Z-Axis

Whole thick samples (like spheroids) are difficult to be fully imaged by CLSM since the fluorescence signal depth in the Z-axis is very limited. To surpass this limitation, both ClearT and ClearT2 methods have demonstrated to be capable of increasing the fluorescence imaging depth in the Z-axis on spheroids [18,19,20,21]. The clearing solutions of these methods homogenize the spheroids overall RI to about 1.44, which leads to a reduction of the light dispersion and improves the excitation and emission light penetration [15]. The better RI homogenization, the greater will be the spheroids transparency and then the traveling of the light throughout the spheroids [33]. Since the transparency of the spheroids is depended on the procedure used to immerse them on the clearing solutions, this may also influence the imaging depth of the PI in the Z-axis. To evaluate such effect, the PI signal depth in the Z-axis was characterized in non-cleared spheroids and those cleared by ClearT/S, ClearT/H, ClearT/R, ClearT2/S, ClearT2/H and ClearT2/R (Figure 4A–C).
The attained results showed that both optical clearing methods allowed to acquire fluorescence at deeper distances in the Z-axis (Figure 4B,C). Such effect was more pronounced when the spheroids were immersed in the clearing solutions under horizontal and/or rotatory agitation. In comparison to the non-cleared spheroids, it was possible to obtain more 29.84 ± 12.41% and 39.53 ± 23.31% PI signal in the Z-axis after the spheroids being cleared by ClearT/H and ClearT/R, respectively (Figure 4B), and more 33.60 ± 7.15% and 56.60 ± 10.40% when the ClearT2/H and ClearT2/R methods were used, respectively (Figure 4C). These results are in agreement with those previously obtained and demonstrate that the use of agitation improves the penetration of the clearing solutions into the spheroids, allowing a better RI homogenization and then a higher spheroids transparency and detection of the fluorescence signal at higher depths in the Z-axis.

3.5. Spheroids Cross-Section Imaging

The acquisition of fluorescence inside the spheroids is very important for therapeutics research purposes. For instance, the imaging of the interior of the spheroids with a fluorescence microscope is crucial to evaluate the dispersion of pharmaceuticals or nanoparticles within the spheroids [49,50,51], as well as to analyze the cellular death and the expression of proteins before and after therapeutics administration [52,53,54]. Nevertheless, the light scattering and its dispersion through the sample hinder the imaging of the spheroids’ interior [18]. Therefore, the cross-section imaging depth in the PI-stained spheroids subjected to ClearT and ClearT2 methods was performed to determine the best incubation conditions. For that purpose, the number of pixels with PI signal inside the spheroids at different depths in Z-axis (25, 50, 75 and 100 µm) was measured [41,42]—Figure 4D.
The obtained results showed that both ClearT and ClearT2 methods allowed to obtain a higher PI fluorescence inside the spheroids when compared to the non-cleared spheroids (Figure 4E–G), being this difference noticeable at 100 µm in the Z-axis. Moreover, the use of agitation during the spheroids incubation with the clearing solutions was one more time crucial to improve the imaging of the interior of the spheroids. In fact, at 100 µm in the Z-axis, the ClearT/H and ClearT2/H methods allowed to obtain more 57.80 ± 18.17 % and 43.00 ± 15.32 % of PI signal inside the spheroids, whereas the ClearT/R and ClearT2/R enhanced the PI signal in 83.79 ± 40.14% and 55.43 ± 31.74%, respectively (Figure 4E,F). Moreover, the CLSM images presented in Figure 4G further support these results, being observed PI-stained cells within deeper regions of the spheroids at a penetration depth of 100 µm when horizontal or rotatory agitation conditions were used, which contrasts with more localize PI fluorescence in the most external layers of the non-cleared or cleared by ClearT/S and ClearT2/S spheroids. Interestingly, the ClearT method allowed to obtain more PI signal inside the spheroids in comparison to those cleared through the ClearT2 method (Figure 4E–G). Such result may be explained by an easier entrance of the formamide-aqueous solutions into the spheroids’ interior, since these are less viscous than the formamide/PEG solutions used in the ClearT2 method.

4. Conclusions

The potential of spheroid tumor models for the in vitro screening of novel anticancer therapeutic approaches was already demonstrated in the literature. Nevertheless, the methods and equipment for extracting data from these models still need to be optimized for application in spheroids. In this field, different studies have been demonstrating that optical clearing methods are crucial for the imaging and analysis of whole spheroids, avoiding the sample sectioning. In this work, the clearing efficacy of ClearT and ClearT2 optical clearing methods and the influence of the incubation conditions of their solutions (static, horizontal agitation, and rotatory agitation) have on the imaging of PI-stained spheroids by CLSM were analyzed (Table 1). Both ClearT and ClearT2 methods can be used to prompt transparency on the spheroids, without affecting their size. ClearT demonstrated to be the best method to image the spheroids’ interior, while ClearT2 allowed to achieve a greater PI fluorescence intensity and a higher PI signal depth in the Z-axis. In both methods, the use of agitation during the spheroids immersion in the clearing solutions resulted in improved imaging of the PI fluorescence in the spheroids, principally when rotatory agitation was employed.
Overall, this article contributes to increasing the amount and accuracy of the data extracted from spheroid models. Additionally, the obtained data can assist other researchers to further optimize the optical clearing methods that will enhance the imaging of whole spheroids. Such is crucial for supporting the application of these models in pharmaceutical research and industry, for instance, to monitor by fluorescence microscopy the cellular death in spheroids prompted by novel anticancer therapeutics.

Author Contributions

Conceptualization, A.F.M. and E.C.C.; formal analysis, E.C.C., D.d.M.-D., and D.N.S.; investigation, C.F.R., D.N.S., E.C.C. and A.F.M.; writing—original draft preparation, E.C.C., I.J.C., and A.F.M.; writing—review and editing, I.J.C., and A.F.M.; visualization, E.C.C.; supervision, I.J.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Foundation for Science and Technology (FCT), grant number UIDB/00709/2020, CENTRO-01-0145-FEDER-028989, and POCI-01-0145-FEDER-031462.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy restrictions.

Acknowledgments

André F. Moreira and Elisabete C. Costa acknowledge for their grants: SFRH/BD/109482/2015 and SFRH/BD/103507/2014, respectively. Duarte de Melo-Diogo acknowledges CENTRO-01-0145-FEDER-028989 for the funding given on the form of a research contract. The funders had no role in the decision to publish or in the preparation of the manuscript.

Conflicts of Interest

The authors declare no financial or commercial conflict of interest.

References

  1. Kapałczyńska, M.; Kolenda, T.; Przybyła, W.; Zajączkowska, M.; Teresiak, A.; Filas, V.; Ibbs, M.; Bliźniak, R.; Łuczewski, Ł.; Lamperska, K. 2D and 3D cell cultures—A comparison of different types of cancer cell cultures. Arch. Med. Sci. 2018, 14, 910–919. [Google Scholar] [CrossRef] [PubMed]
  2. Duval, K.; Grover, H.; Han, L.H.; Mou, Y.; Pegoraro, A.F.; Fredberg, J.; Chen, Z. Modeling physiological events in 2D vs. 3D cell culture. Physiology 2017, 32, 266–277. [Google Scholar] [CrossRef] [PubMed]
  3. Fang, Y.; Eglen, R.M. Three-Dimensional cell cultures in drug discovery and development. SLAS Discov. 2017, 22, 456–472. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Breslin, S.; O’Driscoll, L. Three-Dimensional cell culture: The missing link in drug discovery. Drug Discov. Today 2013, 18, 240–249. [Google Scholar] [CrossRef]
  5. Nunes, A.S.; Barros, A.S.; Costa, E.C.; Moreira, A.F.; Correia, I.J. 3D tumor spheroids as in vitro models to mimic in vivo human solid tumors resistance to therapeutic drugs. Biotechnol. Bioeng. 2019, 116, 206–226. [Google Scholar] [CrossRef] [Green Version]
  6. Van den Brand, D.; Massuger, L.F.; Brock, R. Mimicking tumors: Toward more predictive in vitro models for peptide- and protein-conjugated drugs. Bioconjugate Chem. 2017, 28, 846–856. [Google Scholar] [CrossRef] [Green Version]
  7. Nunes, A.S.; Costa, E.C.; Barros, A.S.; de Melo-Diogo, D.; Correia, I.J. Establishment of 2D cell cultures derived from 3D MCF-7 spheroids displaying a doxorubicin resistant profile. Biotechnol. J. 2018, e1800268. [Google Scholar] [CrossRef]
  8. Gong, X.; Lin, C.; Cheng, J.; Su, J.; Zhao, H.; Liu, T.; Wen, X.; Zhao, P. Generation of multicellular tumor spheroids with microwell-based agarose scaffolds for drug testing. PLoS ONE 2015, 10, e0130348. [Google Scholar] [CrossRef] [Green Version]
  9. Sirenko, O.; Mitlo, T.; Hesley, J.; Luke, S.; Owens, W.; Cromwell, E.F. High-Content assays for characterizing the viability and morphology of 3D cancer spheroid cultures. Assay Drug Dev. Technol. 2015, 13, 402–414. [Google Scholar] [CrossRef]
  10. Oltolina, F.; Zamperone, A.; Colangelo, D.; Gregoletto, L.; Reano, S.; Pietronave, S.; Merlin, S.; Talmon, M.; Novelli, E.; Diena, M.; et al. Human cardiac progenitor spheroids exhibit enhanced engraftment potential. PLoS ONE 2015, 10, e0137999. [Google Scholar] [CrossRef] [Green Version]
  11. Neto, A.I.; Correia, C.R.; Oliveira, M.B.; Rial-Hermida, M.I.; Alvarez-Lorenzo, C.; Reis, R.L.; Mano, J.F. A novel hanging spherical drop system for the generation of cellular spheroids and high throughput combinatorial drug screening. Biomater. Sci. 2015, 3, 581–585. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  12. Lu, H.; Utama, R.H.; Kitiyotsawat, U.; Babiuch, K.; Jiang, Y.; Stenzel, M.H. Enhanced transcellular penetration and drug delivery by crosslinked polymeric micelles into pancreatic multicellular tumor spheroids. Biomater. Sci. 2015, 3, 1085–1095. [Google Scholar] [CrossRef] [PubMed]
  13. Graf, B.W.; Boppart, S.A. Imaging and analysis of three-dimensional cell culture models. Methods Mol. Biol. 2010, 591, 211–227. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Grist, S.M.; Nasseri, S.S.; Poon, T.; Roskelley, C.; Cheung, K.C. On-Chip clearing of arrays of 3-D cell cultures and micro-tissues. Biomicrofluidics 2016, 10, 044107. [Google Scholar] [CrossRef] [Green Version]
  15. Richardson, D.S.; Lichtman, J.W. Clarifying tissue clearing. Cell 2015, 162, 246–257. [Google Scholar] [CrossRef] [Green Version]
  16. Kunz-Schughart, L.A.; Freyer, J.P.; Hofstaedter, F.; Ebner, R. The use of 3-D cultures for high-throughput screening: The multicellular spheroid model. J. Biomol. Screen. 2004, 9, 273–285. [Google Scholar] [CrossRef] [Green Version]
  17. Costa, E.C.; Moreira, A.F.; de Melo-Diogo, D.; Gaspar, V.M.; Carvalho, M.P.; Correia, I.J. 3D tumor spheroids: An overview on the tools and techniques used for their analysis. Biotechnol. Adv. 2016, 34, 1427–1441. [Google Scholar] [CrossRef]
  18. Boutin, M.E.; Hoffman-Kim, D. Application and assessment of optical clearing methods for imaging of tissue-engineered neural stem cell spheres. Tissue Eng. 2015, 21, 292–302. [Google Scholar] [CrossRef] [Green Version]
  19. Costa, E.C.; Moreira, A.F.; de Melo-Diogo, D.; Correia, I.J. ClearT immersion optical clearing method for intact 3D spheroids imaging through confocal laser scanning microscopy. Opt. Laser Technol. 2018, 106, 94–99. [Google Scholar] [CrossRef]
  20. Kabadi, P.K.; Vantangoli, M.M.; Rodd, A.L.; Leary, E.; Madnick, S.J.; Morgan, J.R.; Kane, A.; Boekelheide, K. Into the depths: Techniques for in vitro three-dimensional microtissue visualization. Biotechniques 2015, 59, 279–286. [Google Scholar] [CrossRef]
  21. Costa, E.C.; Moreira, A.F.; de Melo-Diogo, D.; Correia, I.J. Polyethylene glycol molecular weight influences the Clear T2 optical clearing method for spheroids imaging by confocal laser scanning microscopy. J. Biomed. Opt. 2018, 23, 055003. [Google Scholar] [CrossRef]
  22. Chen, Y.; Tsai, Y.-H.; Liu, Y.-A.; Lee, S.-H.; Tseng, S.-H.; Tang, S.-C. Application of three-dimensional imaging to the intestinal crypt organoids and biopsied intestinal tissues. Sci. World J. 2013, 2013, 624342. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Yu, T.; Qi, Y.; Gong, H.; Luo, Q.; Zhu, D. Optical clearing for multiscale biological tissues. J. Biophotonics 2018, 11, 1–13. [Google Scholar] [CrossRef] [PubMed]
  24. Wenzel, C.; Riefke, B.; Gründemann, S.; Krebs, A.; Christian, S.; Prinz, F.; Osterland, M.; Golfier, S.; Räse, S.; Ansari, N.; et al. 3D high-content screening for the identification of compounds that target cells in dormant tumor spheroid regions. Exp. Cell Res. 2014, 323, 131–143. [Google Scholar] [CrossRef] [Green Version]
  25. Desmaison, A.; Guillaume, L.; Triclin, S.; Weiss, P.; Ducommun, B.; Lobjois, V. Impact of physical confinement on nuclei geometry and cell division dynamics in 3D spheroids. Sci. Rep. 2018, 8, 8785. [Google Scholar] [CrossRef] [Green Version]
  26. Schmitz, A.; Fischer, S.C.; Mattheyer, C.; Pampaloni, F.; Stelzer, E.H.K. Multiscale image analysis reveals structural heterogeneity of the cell microenvironment in homotypic spheroids. Sci. Rep. 2017, 7, 43693. [Google Scholar] [CrossRef] [Green Version]
  27. Smyrek, I.; Stelzer, E.H.K. Quantitative three-dimensional evaluation of immunofluorescence staining for large whole mount spheroids with light sheet microscopy. Biomed. Opt. Express 2017, 8, 484–499. [Google Scholar] [CrossRef] [Green Version]
  28. Masson, A.; Escande, P.; Frongia, C.; Clouvel, G.; Ducommun, B.; Lorenzo, C. High-Resolution in-depth imaging of optically cleared thick samples using an adaptive SPIM. Sci. Rep. 2015, 5, 16898. [Google Scholar] [CrossRef] [Green Version]
  29. Santisteban, T.S.; Rabajania, O.; Kalinina, I.; Robinson, S.; Meier, M. Rapid spheroid clearing on a microfluidic chip. Lab Chip 2018, 18, 153–161. [Google Scholar] [CrossRef]
  30. Chen, Y.Y.; Silva, P.N.; Syed, A.M.; Sindhwani, S.; Rocheleau, J.V.; Chan, W.C. Clarifying intact 3D tissues on a microfluidic chip for high-throughput structural analysis. Proc. Natl. Acad. Sci. USA 2016, 113, 14915–14920. [Google Scholar] [CrossRef] [Green Version]
  31. Seo, J.; Choe, M.; Kim, S.Y. Clearing and labeling techniques for large-scale biological tissues. Mol. Cells 2016, 39, 439–446. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  32. Kuwajima, T.; Sitko, A.A.; Bhansali, P.; Jurgens, C.; Guido, W.; Mason, C. ClearT: A detergent- and solvent-free clearing method for neuronal and non-neuronal tissue. Development 2013, 140, 1364–1368. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  33. Feuchtinger, A.; Walch, A.; Dobosz, M. Deep tissue imaging: A review from a preclinical cancer research perspective. Histochem. Cell Biol. 2016, 146, 781–806. [Google Scholar] [CrossRef] [PubMed]
  34. Berke, I.M.; Miola, J.P.; David, M.A.; Smith, M.K.; Price, C. Seeing through musculoskeletal tissues: Improving in situ imaging of bone and the lacunar canalicular system through optical clearing. PLoS ONE 2016, 11, e0150268. [Google Scholar] [CrossRef] [Green Version]
  35. Costa, E.C.; Gaspar, V.M.; Coutinho, P.; Correia, I.J. Optimization of liquid overlay technique to formulate heterogenic 3D co-cultures models. Biotechnol. Bioeng. 2014, 111, 1672–1685. [Google Scholar] [CrossRef]
  36. Rasband, W.S. Image J. Available online: http://rsbweb.nih.gov/ij/ (accessed on 11 March 2019).
  37. Klaka, P.; Grüdl, S.; Banowski, B.; Giesen, M.; Sättler, A.; Proksch, P.; Welss, T.; Förster, T. A novel organotypic 3D sweat gland model with physiological functionality. PLoS ONE 2017, 12, e0182752. [Google Scholar] [CrossRef] [Green Version]
  38. Yu, T.; Qi, Y.; Wang, J.; Feng, W.; Xu, J.; Zhu, J.; Yao, Y.; Gong, H.; Luo, Q.; Zhu, D. Rapid and prodium iodide-compatible optical clearing method for brain tissue based on sugar/sugar-alcohol. J. Biomed. Opt. 2016, 21, 081203. [Google Scholar] [CrossRef] [Green Version]
  39. Ke, M.-T.; Fujimoto, S.; Imai, T. SeeDB: A simple and morphology-preserving optical clearing agent for neuronal circuit reconstruction. Nat. Neurosci. 2013, 16, 1154–1161. [Google Scholar] [CrossRef]
  40. Decroix, L.; Van Muylder, V.; Desender, L.; Sampaolesi, M.; Thorrez, L. Tissue clearing for confocal imaging of native and bio-artificial skeletal muscle. Biotech. Histochem. 2015, 90, 424–431. [Google Scholar] [CrossRef] [Green Version]
  41. Chubinskiy-Nadezhdin, V.I.; Negulyaev, Y.A.; Morachevskaya, E.A. Simvastatin induced actin cytoskeleton disassembly in normal and transformed fibroblasts without affecting lipid raft integrity. Cell Biol. Int. 2017, 41, 1020–1029. [Google Scholar] [CrossRef]
  42. Lipskaia, L.; Hadri, L.; Prince, P.L.; Esposito, B.; Atassi, F.; Liang, L.; Glorian, M.; Limon, I.; Lompre, A.M.; Lehoux, S.; et al. SERCA2a gene transfer prevents intimal proliferation in an organ culture of human internal mammary artery. Gene Ther. 2013, 20, 396–406. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  43. Tainaka, K.; Kuno, A.; Kubota, S.I.; Murakami, T.; Ueda, H.R. Chemical principles in tissue clearing and staining protocols for whole-body cell profiling. Annu. Rev. Cell Dev. Biol. 2016, 32, 713–741. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Lee, E.; Kim, H.J.; Sun, W. See-Through technology for biological tissue: 3-Dimensional visualization of macromolecules. Int. Neurourol. J. 2016, 20, S15–S22. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  45. Fuchs, J.; Dell’Atti, D.; Buhot, A.; Calemczuk, R.; Mascini, M.; Livache, T. Effects of formamide on the thermal stability of DNA duplexes on biochips. Anal. Biochem. 2010, 397, 132–134. [Google Scholar] [CrossRef]
  46. Olive, P.L.; Banath, J.P.; Fjell, C.D. DNA strand breakage and DNA structure influence staining with propidium iodide using the alkaline comet assay. Cytometry 1994, 16, 305–312. [Google Scholar] [CrossRef]
  47. Lasagni, A.; Yuan, D.; Shao, P.; Das, S. Rapid fabrication of biocompatible hydrogels microdevices using laser interference lithography. In Proceedings of the Bioengineered and Bioinspired Systems IV, Dresden, Germany, 20 May 2009; p. 73650I. [Google Scholar]
  48. Jayaramudu, T.; Raghavendra, G.M.; Varaprasad, K.; Reddy, G.V.S.; Reddy, A.B.; Sudhakar, K.; Sadiku, E.R. Preparation and characterization of poly(ethylene glycol) stabilized nano silver particles by a mechanochemical assisted ball mill process. J. Appl. Polym. Sci. 2016, 133. [Google Scholar] [CrossRef]
  49. Nguyen, H.N.; Ha, P.T.; Nguyen, A.S.; Nguyen, D.T.; Do, H.D.; Thi, Q.N.; Thi, M.N.H. Curcumin as fluorescent probe for directly monitoring in vitro uptake of curcumin combined paclitaxel loaded PLA-TPGS nanoparticles. Adv. Nat. Sci. Nanosci. Nanotechnol. 2016, 7, 025001. [Google Scholar] [CrossRef]
  50. Dias, D.R.; Moreira, A.F.; Correia, I.J. The effect of the shape of gold core–mesoporous silica shell nanoparticles on the cellular behavior and tumor spheroid penetration. J. Mater. Chem. 2016, 4, 7630–7640. [Google Scholar] [CrossRef]
  51. Alves, C.G.; de Melo-Diogo, D.; Lima-Sousa, R.; Costa, E.C.; Correia, I.J. Hyaluronic acid functionalized nanoparticles loaded with IR780 and DOX for cancer chemo-photothermal therapy. Eur. J. Pharm. Biopharm. 2019, 137, 86–94. [Google Scholar] [CrossRef]
  52. De Sampaio, P.C.; Auslaender, D.; Krubasik, D.; Failla, A.V.; Skepper, J.N.; Murphy, G.; English, W.R. A heterogeneous in vitro three dimensional model of tumour-stroma interactions regulating sprouting angiogenesis. PLoS ONE 2012, 7, e30753. [Google Scholar] [CrossRef] [Green Version]
  53. Wei, B.; Han, X.-Y.; Qi, C.-L.; Zhang, S.; Zheng, Z.-H.; Huang, Y.; Chen, T.-F.; Wei, H.-B. Coaction of spheroid-derived stem-like cells and endothelial progenitor cells promotes development of colon cancer. PLoS ONE 2012, 7, e39069. [Google Scholar] [CrossRef] [PubMed]
  54. Barros, A.S.; Costa, E.C.; Nunes, A.S.; de Melo-Diogo, D.; Correia, I.J. Comparative study of the therapeutic effect of Doxorubicin and Resveratrol combination on 2D and 3D (spheroids) cell culture models. Int. J. Pharm. 2018, 551, 76–83. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Overview of the PI-stained spheroids optical clearing performed through ClearT and ClearT2 using different spheroids immersion conditions, namely static, horizontal agitation, and rotatory agitation.
Figure 1. Overview of the PI-stained spheroids optical clearing performed through ClearT and ClearT2 using different spheroids immersion conditions, namely static, horizontal agitation, and rotatory agitation.
Ijms 22 00266 g001
Figure 2. Influence of the immersion conditions used to perform the ClearT (A) and ClearT2 (B) methods on HFIB spheroids size and transparency. (A,B) represent the spheroids’ diameter after they were cleared with ClearT and ClearT2 methods under static, horizontal and rotatory agitation, normalized to the average diameter of non-cleared spheroids (388.97 ± 42.94 µm). Optical transparency of a non-cleared spheroid and spheroids cleared by using ClearT and ClearT2 methods under static, horizontal agitation, and rotatory agitation conditions (C). Spheroids were imaged on crosshatched backgrounds for the relative differences in transparency be noticeable. Scale bars correspond to 200 μm. Data are presented as mean ± S.D.; n = 7, p < 0.05, n.s.—non-significant.
Figure 2. Influence of the immersion conditions used to perform the ClearT (A) and ClearT2 (B) methods on HFIB spheroids size and transparency. (A,B) represent the spheroids’ diameter after they were cleared with ClearT and ClearT2 methods under static, horizontal and rotatory agitation, normalized to the average diameter of non-cleared spheroids (388.97 ± 42.94 µm). Optical transparency of a non-cleared spheroid and spheroids cleared by using ClearT and ClearT2 methods under static, horizontal agitation, and rotatory agitation conditions (C). Spheroids were imaged on crosshatched backgrounds for the relative differences in transparency be noticeable. Scale bars correspond to 200 μm. Data are presented as mean ± S.D.; n = 7, p < 0.05, n.s.—non-significant.
Ijms 22 00266 g002
Figure 3. Influence of the immersion conditions used to perform the ClearT and ClearT2 on the PI fluorescence intensity in HFIB spheroids. Fluorescence intensity of PI-stained spheroids after clearing with ClearT (A) and ClearT2 (B) methods under static, horizontal agitation, and rotatory agitation, normalized to the average of the non-cleared spheroids fluorescence intensity. Maximum intensity projections CLSM images with a thickness of 100 µm of non-cleared spheroids and spheroids cleared by ClearT and ClearT2 methods under static, horizontal agitation, and rotatory agitation (C). Scale bars correspond to 200 µm; n = 9, * p < 0.05, n.s.—non-significant.
Figure 3. Influence of the immersion conditions used to perform the ClearT and ClearT2 on the PI fluorescence intensity in HFIB spheroids. Fluorescence intensity of PI-stained spheroids after clearing with ClearT (A) and ClearT2 (B) methods under static, horizontal agitation, and rotatory agitation, normalized to the average of the non-cleared spheroids fluorescence intensity. Maximum intensity projections CLSM images with a thickness of 100 µm of non-cleared spheroids and spheroids cleared by ClearT and ClearT2 methods under static, horizontal agitation, and rotatory agitation (C). Scale bars correspond to 200 µm; n = 9, * p < 0.05, n.s.—non-significant.
Ijms 22 00266 g003
Figure 4. Influence of the immersion conditions used to perform the ClearT and ClearT2 methods on the PI imaging depth in the Z-axis and the PI cross-section imaging depth in HFIB spheroids. Schematic representation of the penetration depth in the Z-axis measured in the spheroids (A). The penetration depth of PI fluorescence signal in the Z-axis of non-cleared spheroids and spheroids cleared by using ClearT (B) and ClearT2 (C) methods under static, horizontal agitation, and rotatory agitation conditions. Schematic representation of the PI cross-section imaging depth measured in the spheroids (D). Cross-section imaging depth of PI fluorescence signal of spheroids cleared by using ClearT (E) and ClearT2 (F) methods under static, horizontal agitation, and rotatory agitation conditions, normalized to the average of the non-cleared spheroids values. Cross-section CLSM images of non-cleared and cleared spheroids by using ClearT and ClearT2 methods under static, horizontal and rotatory agitation conditions (G). Scale bars correspond to 200 µm; n = 9, * p < 0.05, n.s.—non-significant.
Figure 4. Influence of the immersion conditions used to perform the ClearT and ClearT2 methods on the PI imaging depth in the Z-axis and the PI cross-section imaging depth in HFIB spheroids. Schematic representation of the penetration depth in the Z-axis measured in the spheroids (A). The penetration depth of PI fluorescence signal in the Z-axis of non-cleared spheroids and spheroids cleared by using ClearT (B) and ClearT2 (C) methods under static, horizontal agitation, and rotatory agitation conditions. Schematic representation of the PI cross-section imaging depth measured in the spheroids (D). Cross-section imaging depth of PI fluorescence signal of spheroids cleared by using ClearT (E) and ClearT2 (F) methods under static, horizontal agitation, and rotatory agitation conditions, normalized to the average of the non-cleared spheroids values. Cross-section CLSM images of non-cleared and cleared spheroids by using ClearT and ClearT2 methods under static, horizontal and rotatory agitation conditions (G). Scale bars correspond to 200 µm; n = 9, * p < 0.05, n.s.—non-significant.
Ijms 22 00266 g004
Table 1. Overview of ClearT and ClearT2 application in PI-stained spheroids by using different incubation conditions of the clearing solutions.
Table 1. Overview of ClearT and ClearT2 application in PI-stained spheroids by using different incubation conditions of the clearing solutions.
Spheroid’s AnalysisNo ClearingClearTClearT2
StaticHorizontal
Agitation
Rotatory
Agitation
StaticHorizontal
Agitation
Rotatory
Agitation
Spheroids’ size (µm)399.04 ± 39.26473.23 ± 63.24469.90 ± 83.18447.21 ± 13.71478.91 ± 67.10464.77 ± 42.24474.91 ± 33.43
Spheroids’ transparencyNoneModerateHighVery highModerateHighVery High
PI fluorescence (%) a100 ± 22.94104.86 ± 39.1481.71 ± 47.7959.26 ± 10.3892.,65 ± 52.56152.12 ± 33.48186.93 ± 64.25
PI imaging depth
in the Z-axis (µm)
160.45 ± 16.80197.14 ± 42.71208.33 ± 19.92223.89 ± 37.40206.82 ± 23.05214.38 ± 11.48250.77 ± 16.69
PI cross-imaging depth
at 100 µm in the Z-axis (%) a
100.00 ± 10.66122.12 ± 13.48157.80 ± 18.17183.79 ± 40.14124.58 ± 26.86143.00 ± 15.32155.43 ± 31.74
a: Values normalized to the average of the values obtained for non-cleared spheroids (maintained in PBS).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Silva, D.N.; Costa, E.C.; Rodrigues, C.F.; de Melo-Diogo, D.; Correia, I.J.; Moreira, A.F. Influence of ClearT and ClearT2 Agitation Conditions in the Fluorescence Imaging of 3D Spheroids. Int. J. Mol. Sci. 2021, 22, 266. https://doi.org/10.3390/ijms22010266

AMA Style

Silva DN, Costa EC, Rodrigues CF, de Melo-Diogo D, Correia IJ, Moreira AF. Influence of ClearT and ClearT2 Agitation Conditions in the Fluorescence Imaging of 3D Spheroids. International Journal of Molecular Sciences. 2021; 22(1):266. https://doi.org/10.3390/ijms22010266

Chicago/Turabian Style

Silva, Daniel N., Elisabete C. Costa, Carolina F. Rodrigues, Duarte de Melo-Diogo, Ilídio J. Correia, and André F. Moreira. 2021. "Influence of ClearT and ClearT2 Agitation Conditions in the Fluorescence Imaging of 3D Spheroids" International Journal of Molecular Sciences 22, no. 1: 266. https://doi.org/10.3390/ijms22010266

APA Style

Silva, D. N., Costa, E. C., Rodrigues, C. F., de Melo-Diogo, D., Correia, I. J., & Moreira, A. F. (2021). Influence of ClearT and ClearT2 Agitation Conditions in the Fluorescence Imaging of 3D Spheroids. International Journal of Molecular Sciences, 22(1), 266. https://doi.org/10.3390/ijms22010266

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop