A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles
Abstract
:1. Introduction
2. Experimental Section
2.1. Chemicals
2.2. Electrochemical Apparatus
2.3. Electrochemical Synthesis of PEDOT(BSA) Composite for AuNPs/PEDOT(BSA) Electrode
2.4. Enzyme Immobilization
2.5. Electrochemical Measurements
3. Results and Discussion
3.1. Enhancing the Stability of PEDOT Film with BSA
3.2. The Construction of a AuNPs/PEDOT(BSA)/Pt Electrode
3.3. The Immobilization of HRP and Its Bioactivity Measurement
3.4. Electrochemical Responses to H2O2 with Modified Electrodes
3.5. Enhancing the Electrochemical Performance of HRP/AuNPs/PEDOT(BSA)/Pt with NAD+
4. Conclusions
Acknowledgments
Author Contributions
Conflicts of Interest
References
- Kim, T.Y.; Park, C.M.; Kim, J.E.; Suh, K.S. Electronic, chemical and structural change induced by organic solvents in tosylate-doped poly(3,4-ethylenedioxythiophene) (PEDOT-OTs). Synth. Met. 2005, 149, 169–174. [Google Scholar] [CrossRef]
- Kros, A.; Sommerdijk, N.A.J.M.; Nolte, R.J.M. Poly(pyrrole) versus poly (3,4-ethylenedioxythiophene): implications for biosensor applications. Sens. Actuators B Chem. 2005, 106, 289–295. [Google Scholar] [CrossRef]
- Gao, Y.; Li, J.; Yang, X.D.; Xiang, Q.; Wang, K.Q. Electrochemiluminescence Biosensor Based on PEDOT-PSS-Graphene Functionalized ITO Electrode. Electroanalysis 2014, 26, 382–388. [Google Scholar] [CrossRef]
- Phongphut, A.; Sriprachuabwong, C.; Wisitsoraat, A.; Tuantranont, A.; Prichanont, S.; Sritongkham, P. A disposable amperometric biosensor based on inkjet-printed Au/PEDOT-PSS nanocomposite for triglyceride determination. Sens. Actuators B Chem. 2013, 178, 501–507. [Google Scholar] [CrossRef]
- Moczko, E.; Istamboulie, G.; Calas-Blanchard, C.; Rouillon, R.; Noguer, T. Biosensor Employing Screen-Printed PEDOT: PSS for Sensitive Detection of Phenolic Compounds in Water. J. Polym. Sci. Part A Polym. Chem. 2012, 50, 2286–2292. [Google Scholar] [CrossRef]
- Park, J.; Kim, H.K.; Son, Y. Glucose biosensor constructed from capped conducting microtubules of PEDOT. Sens. Actuators B Chem. 2008, 133, 244–250. [Google Scholar] [CrossRef]
- Chen, C.C.; Gu, Y.S. Enhancing the sensitivity and stability of HRP/PANI/Pt electrode by implanted bovine serum albumin. Biosens. Bioelectron. 2008, 23, 765–770. [Google Scholar] [CrossRef] [PubMed]
- Gu, Y.; Lai, M.T. The potential application of a poly(3,4-ethylenedioxythiopene) modified platinum DNA biosensor in mutation analysis. Biosens. Bioelectron. 2012, 31, 124–129. [Google Scholar] [CrossRef] [PubMed]
- Nien, P.C.; Tung, T.S.; Ho, K.C. Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film. Electroanalysis 2006, 18, 1408–1415. [Google Scholar] [CrossRef]
- Radhakrishnan, S.; Sumathi, C.; Dharuman, V.; Wilson, J. Gold nanoparticles functionalized poly(3,4-ethylenedioxythiophene) thin film for highly sensitive label free DNA detection. Anal. Methods 2013, 5, 684–689. [Google Scholar] [CrossRef]
- Luo, S.C.; Xie, H.; Chen, N.Y.; Yu, H.H. Trinity DNA Detection Platform by Ultrasmooth and Functionalized PEDOT Biointerfaces. ACS Appl. Mater. Interfaces 2009, 1, 1414–1419. [Google Scholar] [CrossRef] [PubMed]
- Rozlosnik, N. New directions in medical biosensors employing poly(3,4-ethylenedioxy thiophene) derivative-based electrodes. Anal. Bioanal. Chem. 2009, 395, 637–645. [Google Scholar] [CrossRef] [PubMed]
- Lin, K.C.; Tsai, T.H.; Chen, S.M. Performing enzyme-free H2O2 biosensor and simultaneous determination for AA, DA, and UA by MWCNT-PEDOT film. Biosens. Bioelectron. 2010, 26, 608–614. [Google Scholar] [CrossRef] [PubMed]
- Zhang, H.; Xu, J.K.; Wen, Y.P.; Wang, Z.F.; Zhang, J.; Ding, W.C. Conducting poly(3,4-ethylenedioxythiophene):poly(styrene-sulfonate) film electrode with superior long-term electrode stability in water and synergistically enhanced electrocatalytic ability for application in electrochemical sensors. Synth. Met. 2015, 204, 39–47. [Google Scholar] [CrossRef]
- Chen, C.C.; Do, J.S.; Gu, Y. Immobilization of HRP in Mesoporous Silica and Its Application for the Construction of Polyaniline Modified Hydrogen Peroxide Biosensor. Sensors 2009, 9, 4635–4648. [Google Scholar] [CrossRef] [PubMed]
- Gu, Y.S.; Chen, C.C.; Ruan, Z.W. Enzymatic synthesis of conductive polyaniline using linear BSA as the template in the presence of sodium dodecyl sulfate. Synth. Met. 2009, 159, 2091–2096. [Google Scholar] [CrossRef]
- Li, F.; Feng, Y.; Dong, P.J.; Tang, B. Gold nanoparticles modified electrode via a mercapto-diazoaminobenzene monolayer and its development in DNA electrochemical biosensor. Biosens. Bioelectron. 2010, 25, 2084–2088. [Google Scholar] [CrossRef] [PubMed]
- Pingarron, J.M.; Yanez-Sedeno, P.; Gonzalez-Cortes, A. Gold nanoparticle-based electrochemical biosensors. Electrochimica Acta 2008, 53, 5848–5866. [Google Scholar] [CrossRef]
- Frens, G. Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions. Nat. Phys. Sci. 1973, 241, 20–22. [Google Scholar] [CrossRef]
- Csoregi, E.; Jonssonpettersson, G.; Gorton, L. Mediatorless Electrocatalytic Reduction of Hydrogen-Peroxide at Graphite-Electrodes Chemically-Modified with Peroxidases. J. Biotechnol. 1993, 30, 315–337. [Google Scholar] [CrossRef]
- Pakiari, A.H.; Jamshidi, Z. Nature and Strength of M-S Bonds (M = Au, Ag, and Cu) in Binary Alloy Gold Clusters. J. Phys. Chem. A 2010, 114, 9212–9221. [Google Scholar] [CrossRef] [PubMed]
- Welinder, K.G. Amino-Acid Sequence Studies of Horseradish-Peroxidase. Amino and Carboxyl Termini, Cyanogen-Bromide and Tryptic Fragments, the Complete Sequence, and Some Structural Characteristics of Horseradish Peroxidase-C. Eur. J. Biochem. 1979, 96, 483–502. [Google Scholar] [CrossRef] [PubMed]
- Dawson, J.H. Probing Structure-Function Relations in Heme-Containing Oxygenases and Peroxidases. Science 1988, 240, 433–439. [Google Scholar] [CrossRef] [PubMed]
- Liu, X.J.; Luo, L.Q.; Ding, Y.P.; Xu, Y.H.; Li, F. Hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase on gamma-Al2O3 nanoparticles/chitosan film-modified electrode. J. Solid State Electrochem. 2011, 15, 447–453. [Google Scholar] [CrossRef]
- Solanki, P.R.; Kaushik, A.; Ansari, A.A.; Sumana, G.; Malhotra, B.D. Horse radish peroxidase immobilized polyaniline for hydrogen peroxide sensor. Polym. Adv. Technol. 2011, 22, 903–908. [Google Scholar] [CrossRef]
- Ansari, A.A.; Solanki, P.R.; Malhotra, B.D. Hydrogen peroxide sensor based on horseradish peroxidase immobilized nanostructured cerium oxide film. J. Biotechnol. 2009, 142, 179–184. [Google Scholar] [CrossRef] [PubMed]
- Yang, X.S.; Chen, X.; Zhang, X.; Yang, W.S.; Evans, D.G. Intercalation of methylene blue into layered manganese oxide and application of the resulting material in a reagentless hydrogen peroxide biosensor. Sens. Actuators B Chem. 2008, 129, 784–789. [Google Scholar] [CrossRef]
- Tseng, P.Y.; Ren, S.B.; Gu, Y.S. A novel strategy for the construction of a thermal-durable DNA biosensor modified with conductive poly(3,4-ethylenedioxythiophene) dual-film and gold nanoparticles. J. Taiwan Inst. Chem. Eng. 2016, submitted. [Google Scholar]
Electrode a | Peak Current (μA) b | Sensitivity (μA·mM−1·cm−2) b | ||
No NAD+ | 50 μM NAD+ | No NAD+ | 50 μM NAD+ | |
PEDOT(BSA)/Pt | 114.3 | 127.1 (11.2%) | 572.3 | 628.8 (9.9%) |
AuNPs/PEDOT(BSA)/Pt | 145.1 | 167.3 (15.3%) | 786.2 | 871.2 (10.8%) |
HRP/AuNPs/PEDOT(BSA)/Pt | 132.6 | 188.7 (42.3%) | 719.4 | 974.8 (35.5%) |
© 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Xu, F.; Ren, S.; Gu, Y. A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles. Sensors 2016, 16, 374. https://doi.org/10.3390/s16030374
Xu F, Ren S, Gu Y. A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles. Sensors. 2016; 16(3):374. https://doi.org/10.3390/s16030374
Chicago/Turabian StyleXu, Fangcheng, Shuaibin Ren, and Yesong Gu. 2016. "A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles" Sensors 16, no. 3: 374. https://doi.org/10.3390/s16030374
APA StyleXu, F., Ren, S., & Gu, Y. (2016). A Novel Conductive Poly(3,4-ethylenedioxythiophene)-BSA Film for the Construction of a Durable HRP Biosensor Modified with NanoAu Particles. Sensors, 16(3), 374. https://doi.org/10.3390/s16030374