In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations
Abstract
:1. Introduction
2. Materials and Methods
2.1. Tooth Selection
2.2. Sample Preparation
2.3. Electronic Working Length Determination
- (a)
- Root ZX II (J Morita Corp, Osaka, Japan):
- (b)
- Apex ID (SybronEndo, Orange, CA, USA):
- (c)
- Dual Pex (Micro Méga, Boissy St-Léger, France).
2.4. Statistical Analysis
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Pascon, E.; Marrelli, M.; Congi, O.; Ciancio, R.; Miceli, F.; Versiani, M.A. An ex vivo comparison of working length determination by 3 electronic apex locators. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 2009, 108, e147–e151. [Google Scholar] [CrossRef] [PubMed]
- Schilder, H. Canal debridement and disinfection. In Cohen S & Burns RC, Eds Pathways of the Pulp, 2nd ed.; C.V. Mosby: St. Louis, MO, USA, 1976; pp. 111–132. [Google Scholar]
- ElAyouti, A.; Hülber, J.M.; Judenhofer, M.S.; Connert, T.; Mannheim, J.G.; Löst, C.; Pichler, B.J.; von Ohle, C. Apical Constriction: Location and Dimensions in Molars—A Micro–Computed Tomography Study. J. Endod. 2014, 40, 1095–1099. [Google Scholar] [CrossRef] [PubMed]
- Wu, M.-K.; Wesselink, P.R.; Walton, R.E. Apical terminus location of root canal treatment procedures. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 2000, 89, 99–103. [Google Scholar] [CrossRef]
- Dummer, P.; McGinn, J.H.; Rees, D.G. The position and topography of the apical canal constriction and apical foramen. Int. Endod. J. 1984, 17, 192–198. [Google Scholar] [CrossRef] [PubMed]
- Ricucci, D.; Langeland, K. Apical limit of root canal instrumentation and obturation, part 2. A histological study. Int. Endod. J. 1998, 31, 394–409. [Google Scholar] [CrossRef]
- Chang, J.W.-W.; Manigandan, K.; Samaranayake, L.; NandhaKumar, C.; AdhityaVasun, P.; Diji, J.; PradeepKumar, A.R. Morphotypes of the apical constriction of maxillary molars: A micro-computed tomographic evaluation. Restor. Dent. Endod. 2022, 47, e19. [Google Scholar] [CrossRef]
- Ng, Y.-L.; Mann, V.; Rahbaran, S.; Lewsey, J.; Gulabivala, K. Outcome of primary root canal treatment: Systematic review of the literature—Part 2. Influence of clinical factors. Int. Endod. J. 2008, 41, 6–31. [Google Scholar] [CrossRef]
- Ng, Y.-L.; Mann, V.; Gulabivala, K. A prospective study of the factors affecting outcomes of nonsurgical root canal treatment: Part 1: Periapical health. Int. Endod. J. 2011, 44, 583–609. [Google Scholar] [CrossRef]
- Kuttler, Y. Microscopic investigation of root apexes. J. Am. Dent. Assoc. 1955, 50, 544–552. [Google Scholar] [CrossRef]
- Lucena, C.; López, J.M.; Martín, J.A.; Robles, V.; González-Rodríguez, M.P. Accuracy of working length measurement: Electronic apex locator versus cone-beam computed tomography. Int. Endod. J. 2014, 47, 246–256. [Google Scholar] [CrossRef]
- Versiani, M.A.; Pécora, J.D.; Sousa-Neto, M.D. Microcomputed tomography analysis of the root canal morphology of single-rooted mandibular canines. Int. Endod. J. 2013, 46, 800–807. [Google Scholar] [CrossRef] [PubMed]
- Nekoofar, M.H.; Ghandi, M.M.; Hayes, S.J.; Dummer, P.M.H. The fundamental operating principles of electronic root canal length measurement devices. Int. Endod. J. 2006, 39, 595–609. [Google Scholar] [CrossRef] [PubMed]
- Nekoofar, M.; Sadeghi, K.; Akha, E.S.; Namazikhah, M.S. The Accuracy of the Neosono Ultima EZ Apex Locator Using Files of Different Alloys: An In Vitro Study. J. Calif. Dent. Assoc. 2002, 30, 681–684. [Google Scholar] [CrossRef] [PubMed]
- Kobayashi, C.; Suda, H. New electronic canal measuring device based on the ratio method. J. Endod. 1994, 20, 111–114. [Google Scholar] [CrossRef]
- Gordon, M.P.J.; Chandler, N.P. Electronic apex locators. Int. Endod. J. 2004, 37, 425–437. [Google Scholar] [CrossRef]
- Versiani, M.A.; Santana, B.P.; Caram, C.M.; Pascon, E.; de Souza, C.J.A.; Biffi, J.C.G. Ex vivo comparison of the accuracy of Root ZX II in detecting apical constriction using different meter’s reading. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 2009, 108, e41–e45. [Google Scholar] [CrossRef]
- Mahmoud, O.; Abdelmagied, M.H.A.; Dandashi, A.H.; Jasim, B.N.; Kayali, H.A.T.; Al Shehadat, S. Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph—In Vitro Study. Int. J. Dent. 2021, 2021, 5563426. [Google Scholar] [CrossRef]
- Piasecki, L.; Carneiro, E.; Neto, U.X.D.S.; Westphalen, V.P.D.; Brandão, C.G.; Gambarini, G.; Azim, A.A. The Use of Micro–Computed Tomography to Determine the Accuracy of 2 Electronic Apex Locators and Anatomic Variations Affecting Their Precision. J. Endod. 2016, 42, 1263–1267. [Google Scholar] [CrossRef]
- Di Spirito, F.; Pisano, M.; Caggiano, M.; Bhasin, P.; Giudice, R.L.; Abdellatif, D. Root Canal Cleaning after Different Irrigation Techniques: An Ex Vivo Analysis. Medicina 2022, 58, 193. [Google Scholar] [CrossRef]
- Simeone, M.; Valletta, A.; Giudice, A.; Di Lorenzo, P.; Iandolo, A. The activation of irrigation solutions in Endodontics: A perfected technique. G. Ital. Endod. 2015, 29, 65–69. [Google Scholar] [CrossRef]
- Gu, L.-S.; Kim, J.R.; Ling, J.; Choi, K.K.; Pashley, D.H.; Tay, F.R. Review of Contemporary Irrigant Agitation Techniques and Devices. J. Endod. 2009, 35, 791–804. [Google Scholar] [CrossRef] [PubMed]
- Cîmpean, S.I.; Pop-Ciutrila, I.-S.; Matei, S.-R.; Colosi, I.A.; Costache, C.; Nicula, G.Z.; Badea, I.C.; Burtea, L.C. Effectiveness of Different Final Irrigation Procedures on Enterococcus faecalis Infected Root Canals: An In Vitro Evaluation. Materials 2022, 15, 6688. [Google Scholar] [CrossRef] [PubMed]
- Diemer, F.; Plews, E.; Georgelin-Gurgel, M.; Mishra, L.; Kim, H.-C. Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability. Materials 2022, 15, 863. [Google Scholar] [CrossRef]
- Tinaz, A.C.; Sevimli, L.S.; Görgül, G.; Türköz, E.G. The Effects of Sodium Hypochloride Concentrations on the Accuracy of an Apex Locating Device. J. Endod. 2002, 28, 160–162. [Google Scholar] [CrossRef]
- Chukka, R.R.; Bellam, M.D.; Marukala, N.R.; Dinapadu, S.; Konda, N.K.; Nagilla, J. Efficiency of an integrated apex locator in determining working length in various irrigating solutions: An in vivo study. J. Pharm. Bioallied Sci. 2020, 12, S410–S414. [Google Scholar] [CrossRef]
- Tinaz, A.C.; Maden, M.; Aydin, C.; Türköz, E. The accuracy of three different electronic root canal measuring devices: An in vitro evaluation. J. Oral Sci. 2002, 44, 91–95. [Google Scholar] [CrossRef] [PubMed]
- Schneider, S.W. A comparison of canal preparations in straight and curved root canals. Oral Surg. Oral Med. Oral Pathol. 1971, 32, 271–275. [Google Scholar] [CrossRef] [PubMed]
- D’assunção, F.L.C.; de Albuquerque, D.S.; Salazar-Silva, J.R.; Ferreira, L.C.D.Q.; Bezerra, P.M. The accuracy of root canal measurements using the Mini Apex Locator and Root ZX-II: An evaluation in vitro. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 2007, 104, e50–e53. [Google Scholar] [CrossRef]
- Lucena-Martín, C.; Robles-Gijón, V.; Ferrer-Luque, C.M.; De Mondelo, J.M.N.-R. In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators. J. Endod. 2004, 30, 231–233. [Google Scholar] [CrossRef]
- Plotino, G.; Grande, N.M.; Brigante, L.; Lesti, B.; Somma, F. Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator and ProPex. Int. Endod. J. 2006, 39, 408–414. [Google Scholar] [CrossRef]
- Bergenholtz, G.; Lekholm, U.; Milthon, R.; Engstrom, B. Influence of apical overinstrumentation and overfilling on re-treated root canals. J. Endod. 1979, 5, 310–314. [Google Scholar] [CrossRef] [PubMed]
- ElAyouti, A.; Weiger, R.; Löst, C. The Ability of Root ZX Apex Locator to Reduce the Frequency of Overestimated Radiographic Working length. J. Endod. 2002, 28, 116–119. [Google Scholar] [CrossRef]
- Kim, E.; Marmo, M.; Lee, C.-Y.; Oh, N.-S.; Kim, I.-K. An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 2008, 105, e79–e83. [Google Scholar] [CrossRef] [PubMed]
- Oliveira, T.N.; Vivacqua-Gomes, N.; Bernardes, R.A.; Vivan, R.R.; Duarte, M.A.H.; Vasconcelos, B.C. Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols. J. Endod. 2017, 43, 1663–1667. [Google Scholar] [CrossRef] [PubMed]
- Serna-Peña, G.; Gomes-Azevedo, S.; Flores-Treviño, J.; Madla-Cruz, E.; Rodríguez-Delgado, I.; Martínez-González, G. In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi. J. Endod. 2020, 46, 158–161. [Google Scholar] [CrossRef]
- Moscoso, S.; Pineda, K.; Basilio, J.; Alvarado-Barrios, C.; Roig, M.; Duran-Sindreu, F. Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study. Med. Oral Patol. Oral Cir. Bucal. 2014, 19, e202–e205. [Google Scholar] [CrossRef]
- Connert, T.; Judenhofer, M.S.; Hülber, J.M.; Schell, S.; Mannheim, J.G.; Pichler, B.J.; Löst, C.; ElAyouti, A. Evaluation of the accuracy of nine electronic apex locators by using Micro-CT. Int. Endod. J. 2018, 51, 223–232. [Google Scholar] [CrossRef]
- Duran-Sindreu, F.; Gomes, S.; Stöber, E.; Mercadé, M.; Jané, L.; Roig, M. In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants. Int. Endod. J. 2013, 46, 769–774. [Google Scholar] [CrossRef]
- Wrbas, K.T.; Ziegler, A.A.; Altenburger, M.J.; Schirrmeister, J.F. In vivo comparison of working length determination with two electronic apex locators. Int. Endod. J. 2007, 40, 133–138. [Google Scholar] [CrossRef]
- Venturi, M.; Breschi, L. A comparison between two electronic apex locators: An ex vivo investigation. Int. Endod. J. 2007, 40, 362–373. [Google Scholar] [CrossRef]
- Ding, J.; Gutmann, J.L.; Fan, B.; Lu, Y.; Chen, H. Investigation of Apex Locators and Related Morphological Factors. J. Endod. 2010, 36, 1399–1403. [Google Scholar] [CrossRef] [PubMed]
- Katz, A.; Mass, E.; Kaufman, A.Y. Electronic apex locator: A useful tool for root canal treatment in the primary dentition. ASDC J. Dent. Child. 1996, 63, 414–417. [Google Scholar] [PubMed]
- Wolf, T.G.; Krauß-Mironjuk, A.; Wierichs, R.J.; Briseño-Marroquín, B. Influence of embedding media on the accuracy of working length determination by means of apex locator: An ex vivo study. Sci. Rep. 2021, 11, 3340. [Google Scholar] [CrossRef] [PubMed]
Criteria | Inclusion | Exclusion |
---|---|---|
Teeth | Complete root formation Canal configuration type I Degree of curvature less than 20° | Previous root canal treatment Presence of cracks Presence of root caries Calcified canals Clinical or radiological signs of internal or external root resorptions |
Operator | EAL | Solution | N | * Mean | SD |
---|---|---|---|---|---|
Op1 | Apex ID | 2% | 20 | 0.325 | 0.309 |
5.25% | 20 | 0.510 | 0.477 | ||
Dual Pex | 2% | 20 | 0.390 | 0.332 | |
5.25% | 20 | 0.225 | 0.220 | ||
Root ZX II | 2% | 20 | 0.290 | 0.269 | |
5.25% | 20 | 0.470 | 0.393 | ||
Op2 | Apex ID | 2% | 20 | 0.345 | 0.344 |
5.25% | 20 | 0.495 | 0.462 | ||
Dual Pex | 2% | 20 | 0.305 | 0.263 | |
5.25% | 20 | 0.355 | 0.341 | ||
Root ZX II | 2% | 20 | 0.380 | 0.261 | |
5.25% | 20 | 0.475 | 0.360 |
S1 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Root ZX II | Apex ID | Dual Pex | ||||||||||
Between | Op1 | Op2 | Op1 | Op2 | Op1 | Op2 | ||||||
n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | |
* −0.5 to 0 | 6 | 30 | 3 | 15 | 3 | 15 | 2 | 10 | 6 | 30 | 7 | 35 |
0 | 7 | 35 | 4 | 20 | 6 | 30 | 7 | 35 | 4 | 20 | 4 | 20 |
0 to 0.5 | 5 | 25 | 10 | 50 | 7 | 35 | 7 | 35 | 7 | 35 | 7 | 35 |
0.5 to 1 | 2 | 10 | 3 | 15 | 4 | 20 | 4 | 20 | 3 | 15 | 2 | 10 |
S2 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Root ZX II | Apex ID | Dual Pex | ||||||||||
Between | Op1 | Op2 | Op1 | Op2 | Op1 | Op2 | ||||||
n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | n = 20 | % | |
* <−1 | 0 | - | 0 | - | 1 | 5 | 2 | 10 | 0 | - | 0 | - |
* −1 to −0.5 | 2 | 10 | 3 | 15 | 3 | 15 | 3 | 15 | 0 | - | 3 | 15 |
∗ −0.5 to 0 | 9 | 45 | 10 | 50 | 10 | 50 | 9 | 45 | 9 | 45 | 8 | 40 |
0 | 3 | 15 | 3 | 15 | 3 | 15 | 5 | 25 | 7 | 35 | 6 | 30 |
0 to 0.5 | 3 | 15 | 2 | 10 | 2 | 10 | 1 | 5 | 4 | 20 | 2 | 10 |
0.5 to 1 | 2 | 10 | 2 | 10 | 1 | 5 | 0 | - | 0 | - | 1 | 5 |
<1 | 1 | 5 | 0 | - | 0 | - | 0 | - | 0 | - | 0 | - |
EAL | p | pbonf | pholm |
---|---|---|---|
ApexID—Dual Pex | * | 0.068 | 0.068 |
ApexID—Root ZX II | 0.831 | 1.000 | 0.831 |
Dual Pex—Root ZX II | * | 0.116 | 0.077 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Cîmpean, S.I.; Chisnoiu, R.M.; Colceriu Burtea, A.L.; Rotaru, R.; Bud, M.G.; Delean, A.G.; Pop-Ciutrilă, I.-S. In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations. Medicina 2023, 59, 918. https://doi.org/10.3390/medicina59050918
Cîmpean SI, Chisnoiu RM, Colceriu Burtea AL, Rotaru R, Bud MG, Delean AG, Pop-Ciutrilă I-S. In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations. Medicina. 2023; 59(5):918. https://doi.org/10.3390/medicina59050918
Chicago/Turabian StyleCîmpean, Sanda Ileana, Radu Marcel Chisnoiu, Adela Loredana Colceriu Burtea, Rareș Rotaru, Marius Gheorghe Bud, Ada Gabriela Delean, and Ioana-Sofia Pop-Ciutrilă. 2023. "In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations" Medicina 59, no. 5: 918. https://doi.org/10.3390/medicina59050918
APA StyleCîmpean, S. I., Chisnoiu, R. M., Colceriu Burtea, A. L., Rotaru, R., Bud, M. G., Delean, A. G., & Pop-Ciutrilă, I. -S. (2023). In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite Concentrations. Medicina, 59(5), 918. https://doi.org/10.3390/medicina59050918