Next Article in Journal
Determining the Effect of Different Heat Treatments on the Electrical and Morphological Characteristics of Polymer Solar Cells
Next Article in Special Issue
Research on Gas-Path Fault-Diagnosis Method of Marine Gas Turbine Based on Exergy Loss and Probabilistic Neural Network
Previous Article in Journal
Comparison of Heat-Pipe Cooling System Design Processes in Railway Propulsion Inverter Considering Power Module Reliability
Previous Article in Special Issue
The Use of Acoustic Emission to Diagnosis of Fuel Injection Pumps of Marine Diesel Engines
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Marine Gas Turbine Fault Diagnosis Method Based on Endogenous Irreversible Loss

College of Power and Energy Engineering, Harbin Engineering University, Harbin 150001, China
*
Author to whom correspondence should be addressed.
Energies 2019, 12(24), 4677; https://doi.org/10.3390/en12244677
Submission received: 31 October 2019 / Revised: 2 December 2019 / Accepted: 4 December 2019 / Published: 9 December 2019

Abstract

:
When a malfunction occurs in a marine gas turbine, its thermal efficiency will decrease slightly, and the gas path fault is often difficult to distinguish. In order to solve this problem, based on the second law of thermodynamics, the endogenous irreversible loss (EIL) model of the marine gas turbine is established, and the exergy loss analysis under normal conditions is carried out to verify the accuracy of the model. The fault diagnosis of gas turbine gas path based on EIL is proposed, and a simulation experiment conducted on a three-shaft marine gas turbine demonstrated that the proposed approach can detect and isolate gas path fault accurately under different operating conditons and enviroments.

1. Introduction

A gas turbine is a complex thermal system. Its operation process is a cross-coupled thermodynamic process. When a certain component fails, it often causes the performance degradation of the entire equipment and even catastrophic consequences. The high-speed airflow passage composed of several components of the gas turbine is collectively referred to as the gas path. Since the turbine is required to inhale a large amount of air during operation, the air often contains salt ingested particles, moisture, and other corrosive substances, which may cause damage to the interior of the turbine. These gas path components are subject to wear, corrosion, fouling, and other external damage, which in turn causes the performance of the gas turbine to decrease [1,2]. Therefore, it is necessary to find a way to accurately monitor the gas path failure.
In recent years, many gas path fault diagnosis methods have been proposed to assess gas turbine health status, such as nonlinear gas path analysis [3,4,5], rule-based fuzzy expert system [6,7], Bayesian hierarchical models [8,9], neural networks [10,11,12], genetic algorithm [13,14], multiple-model method [15,16], and exergy analysis [17]. Gas path analysis is an inversely mathematical problem to obtain the deviation of component performance parameters over gas path measured variables. Most case studies show that artificial intelligence methods, such as artificial neural networks, Bayesian hierarchical models, and fuzzy expert systems, may effectively isolate the faulty components but not easily assess the severity of the fault [18].
The model-based approach is an analytical redundancy approach that diagnoses the fault based on the residual signal between the measurements and the gas turbine’s mathematical model. Kalman filter is a typical model-based approach and is widely used in gas path fault diagnosis [18]. However, model-based approaches require accurate gas turbine mathematical models, and their reliability decreases as system complexity increases. Meanwhile, when a gas path fault occurs, the parameter change may be extremely weak and difficult to monitor.
It is a new idea and direction to diagnose the gas path of gas turbine based on the exergy loss [19,20,21,22,23,24,25]. According to the second law of thermodynamics, we know that the exergy efficiency is an important indicator to measure the irreversibility of the work of the thermal system. The exergy loss is an actual loss in the process of energy conversion. Therefore, it is more suitable to describe the function of a thermal system. And when the fault occurs, the change of the exergy loss is greater than the rest of the thermal parameters, which can improve the sensitivity of the diagnosis. In recent years, on the basis of exergy research, some scholars have proposed the concept of thermoeconomic [26,27,28,29], not only based on the second law of thermodynamics, but also introduced the basic ideas of system engineering, optimization theory, and decision theory, capable of analyzing complex energy systems.
When a gas turbine fault occurs, the exergy loss of the gas turbine is divided into exogenous irreversible loss and endogenous irreversible loss (EIL) [30,31,32]—where the EIL can better characterize the impact of the gas turbine component itself, and the complicated coupling relationship of gas turbines and the EIL of internal sources may also change when other components fail. Therefore, the use of the EIL for fault diagnosis is the key research content of this paper.
At present, most of the fault diagnosis based on the exergy balance analysis principle of gas turbines is on industrial single-shaft or two-shaft gas turbines, while there are few studies on marine three-shaft gas turbines. Furthermore, the coupling relationship of the three-shaft marine gas turbine is more complicated. The operating environment of the marine gas turbine is more complicated and harsh than the industrial gas turbine, and the operating conditions are more variable. A new fault diagnosis method suitable for the marine three-shaft gas turbine is urgently needed.
In this regard, we have conducted the following research. In Section 2, the EIL models of the marine gas turbine under healthy and faulty are established. In Section 3, the diagnosis process based on the EIL is established. In Section 4, taking marine three-shaft gas turbine as the object, a fault diagnosis algorithm based on EIL is proposed, which is used for the verification of the algorithm under the condition of typical gas path fault.

2. EIL Model of Gas Turbine

Slight changes in performance parameters may cause changes in multiple thermal parameters of marine gas turbines under different operating conditions. Slight changes in thermal parameters are difficult to identify, causing problems with diagnostic difficulties. On the basis of the second law of thermodynamics, the use of exergy balance has better sensitivity for fault diagnosis of marine gas turbine gas paths.
This section introduces the exergy balance analysis method and establishes its physical structure and productive structure by analyzing the working principle of the marine gas turbine. Then, based on the nonlinear model of the marine gas turbine [33], the EIL model of marine gas turbine is established.

2.1. EIL Analysis of Gas Turbine

The exergy analysis method is based on the second law of thermodynamics, which provide a method to measure the actual performance and identify the causes of thermodynamic losses. Since the energy of different forms has mutual conservation of mass and qualitative difference, the two properties are different. As a physical quantity for evaluating energy value, exergy is a physical quantity that reflects both the “mass” and “quantity” of energy. In various forms of energy, such as mechanical energy, electrical energy, etc. which can all be converted into heat energy, the theoretical conversion efficiency is close to 100%, and this kind of energy that can be converted infinitely is called exergy, which is recorded as B.
Exergy loss occurs in any actual process, that is, a portion of the fuel exergy is lost during the production process. Using the definition of fuel and product, the process component exergy balance can be expressed as:
F = P + I
where F represents the component fuel, P which represents the component product, and I represents the loss of exergy of the component.
Therefore, fuel consumption is also related to the EIL of the process (exergy loss), which can be characterized by the unit consumption k.
k = F / P
When a gas path fault occurs in a marine gas turbine, the exergy must change. The changed part is composed of endogenous irreversible loss (EIL) and exogenous irreversible loss. The EIL can characterize the impact of fault for the marine gas turbine unit itself better. At the same time, due to the complex coupling relationship of the gas turbine, the EIL may also change greatly when other components fail. Compared with the other thermodynamic parameters for fault diagnosis, the EIL for fault diagnosis increases its sensitivity, and the number of parameters used is reduced, which simplifies the complexity of diagnosis. Thus, it is a new research direction.
According to the definition of “fuel-product” [34,35], in the normal condition, the product of the former component is the fuel of the latter component, and the rest is the exergy loss. When the component fault occurs, it causes additional exergy loss of the component, i.e., ΔP, and the required fuel also increases, i.e., ΔF.
Due to the complex coupling relationship of gas turbines, the “fuel-products” between the various components are linked. Taking two components as an example in Figure 1:
The expression is:
F 1 = P 1 + I 1 , F 2 = P 2 + I 2 , P 1 = F 2
The unit loss means that the exergy loss can be expressed as:
I = F P = ( k 1 ) P
The total differential of equation (4) is expressed as:
d I = P 0 d k + ( k 1 ) d P
It can be seen that the exergy loss consists of two components; one is the EIL, and the other is the exogenous irreversible loss. Since the EIL can accurately reflect the changes in the operating characteristics of the equipment unit, and to some extent exclude the influence of other equipment units, it is suitable as a feature for equipment failure.
The EIL due to the change in component unit consumption is:
M F = P 0 Δ k

2.2. Physical Structure and Productive Structure of the Marine Gas Turbine

In order to exergy balance analysis, a marine gas turbine is divided into several components or process components. A process component is a functional component that has a production purpose corresponding to a real device. However, the process component is not necessarily a specific physical structure device, and different devices can be combined into one process component, or one physical structure device can be further decomposed into several process components.
The productive structure model is to facilitate the analysis of the physical structure of the system and the depreciation of each flow. The structural characteristics of the marine gas turbine were analyzed in Figure 2. It can be seen that the air (0) is compressed by the low-pressure compressor (LC) to generate the low-pressure air (1) and then continues to be compressed by the high-pressure compressor (HC) to generate high-pressure air (2). The high-pressure air (2) and the fuel (10) are fully mixed and burned in the combustion chamber (CC) to form high temperature and high-pressure gas (3). The gas (3) enters the high-pressure turbine to expand to do work, the generated energy (8) drives the high-pressure compressor to rotate, and the expanded gas (4) enters the low-pressure turbine (LC) for further expansion, the energy (9) generated by low-pressure turbine drives the low-pressure compressor to rotate. Finally, the expanded gas (5) enters the power turbine (PT) to continue to expand to do work, the generated energy (6) drives the generator(G) to generate electricity (7), and the exhaust (11) is discharged into the atmosphere. According to the energy flow and mass flow described in Figure 2, the physical structure of the gas turbine is shown in Figure 3.
As can be seen from Figure 3, the marine gas turbine is divided into six components: The low-pressure compressor, the high-pressure compressor, the combustor, the high-pressure turbine, the low-pressure turbine, and the power turbine. The generator connected to the power turbine belongs to the gas turbine. The process of physical flow is shown by the arrow, and there are 11 physical flows between components and the environment.
From the physical structure, we can establish the productive structure of the marine gas turbine, as shown in Figure 4. There are two fuels in the low-pressure compressor, one is F1 which is supplied by the product P5 that is produced by the low-pressure turbine, and the other is flow 0, and its exergy is equal to 0. The product of the low-pressure compressor is exergy flow P1. The fuel F2 of the high-pressure compressor comes from the product of high-pressure turbine P4, and its product is exergy flow P2. The fuel of the combustor is fossil fuel F3, and its product is P3. We can see from Figure 3, the expansion gas is not fully expanded in the high-pressure turbine; it also enters low-pressure turbine and the power turbine to continue to expand, so a junction point “J” to present the sum of useful product P1, P2, and P3, and a breakpoint “B” to present the relationship that product divided into three fuel flows, F4 enters into high-pressure turbine, F5 enters into low-pressure turbine, and F6 enters into power turbine. P6 is the product of the power turbine and is also the fuel of generator. It can be seen from Figure 4, the productive structure indicates a detailed analysis of the “production” and “consumption” processes of the marine gas turbine.

2.3. EIL Model of Components

The establishment of the productive structure makes the resource allocation of the marine gas turbine represented graphically. According to the productive structure, the “fuel” and “product” of each process component were analyzed. The EIL model of the marine gas turbine can be established according to the productive structure.

2.3.1. EIL Model of Compressors

The compressor is one of the main components of the gas turbine, which uses the mechanical energy supplied by the low-pressure turbine to continuously compress and deliver the gas. For compressor simulation modeling, compressor characteristics are particularly important. It is necessary to obtain the flow and efficiency by converting the speed and pressure ratio. The enthalpy and entropy of equipment inlet and outlet are functions of temperature, which can be obtained by fitting equation, so as to calculate the exergy of equipment inlet and outlet.
The calculation equation of the EIL of the low-pressure compressor is:
M F 1 = P 1 ( F 1 P 1 F 1 P 1 )
P 1 = h 1 h 0 T 0 ( s 1 s 0 )
F 1 = 1 2 J L C L T ω 2
where h1 is the outlet enthalpy of the low-pressure compressor and s1 is the outlet entropy of the low-pressure compressor. MF1 is the EIL of the low-pressure compressor, F 1 is the fuel and P 1 is the product of the low-pressure compressor in a fault condition, F1 and P1 are the fuel and the product of low-pressure compressor in normal condition.
The calculation equation of the EIL of the high-pressure compressor is:
M F 2 = P 2 ( F 2 P 2 F 2 P 2 )
P 2 = h 2 h 0 T 0 ( s 2 s 0 ) [ h 1 h 0 T 0 ( s 1 s 0 ) ]
F 2 = 1 2 J H C H T ω 2
where MF2 is the EIL of high-pressure compressor, F 2 is the fuel and P 2 is the product of high-pressure compressor in a faulty condition, F2 is the fuel and P2 is the product of high-pressure compressor in normal condition.

2.3.2. EIL Model of the Combustion Chamber

The role of the combustion chamber is to mix the high-pressure air from the high-pressure compressor with the fuel injected by the fuel nozzle and burn it, then convert the chemical energy contained in the fuel into heat energy, forming high-temperature gas to enter the high-pressure turbine for work.
When there is a chemical imbalance between substance (logistics) and environment, its chemical exergy should be calculated. Although when the fuel in the environmental condition is in thermal balance with the environment, there is still chemical imbalance, so it can react with oxygen in the air to release the chemical energy of the fuel. The approximate calculation equation of liquid fuel exergy:
B x l = 0.975 Δ H h
where Δ H h is the high calorific value of the fuel, (kJ/kg).
The calculation equation of the EIL of the combustion chamber is:
M F 3 = P 3 ( F 3 P 3 F 3 P 3 )
P 3 = h 3 h 0 T 0 ( s 3 s 0 ) [ h 2 h 0 T 0 ( s 2 s 0 ) ]
F 3 = 0.975 Δ H u f
f = G f G B i n
where MF3 is the EIL of the combustion chamber, F 3 is the fuel and P 3 is the product of combustion chamber in a fault condition, F3 is the fuel and P3 is the product of the combustion chamber in normal condition.
It can be seen from the productive structure in Figure 4 that there are three exergy flows after the combustion chamber: The product P3, the product of low-pressure compressor P1 (Flow 1), and the product of high-pressure compressor P2 (Flow 2). Therefore, the product at the junction point “J” is the sum of these three products, P J = P 1 + P 2 + P 3 = h 3 h 0 T 0 ( s 3 s 0 ) , and the product P J = P 3 is the fuel of breakpoint “B”, and it is divided into F 4 , F 5 , and F 6 . They are the fuel of the high-pressure turbine, low-pressure turbine, and power turbine, respectively.

2.3.3. EIL Model of Turbines

The turbine is a kind of rotary machinery that transforms gas heat energy into mechanical energy. There are many similarities between a turbine and a compressor. The marine gas turbine has a high-pressure turbine, a low-pressure turbine, and a power turbine, whose functions are to drive the high-pressure compressor, the low-pressure compressor, and output load, respectively.
The turbine and compressor are the same turbomachinery, which exchanges energy with airflow, so they have many similarities. The enthalpy and entropy of the turbine inlet and outlet can also be obtained by fitting the equation, and then the exergy of inlet and outlet can be obtained.
As a gas turbine, the power turbine converts energy into mechanical work, which is used to drive the turbomachinery with external load (propeller, motor, etc.). Therefore, P6 = Wnet. The gas at the outlet of the low-pressure turbine is expanded for the last time in the power turbine to output external mechanical power and exhaust gas. For the exhaust, this paper considers that there is no waste heat boiler and other devices, the exhaust is discharged to the atmospheric environment, and this energy is considered to be 0.
In addition, for the P4 and P5 flows in the productive structure diagram, they are the energy that the low-pressure turbine and the high-pressure turbine drive the low-pressure compressor and the high-pressure compressor to rotate. Both of these energies are mechanical energy. All mechanical energy is available energy.
The calculation equation of the EIL of the high-pressure turbine is:
M F 4 = P 4 ( F 4 P 4 F 4 P 4 )
P 4 = 1 2 J H C H T ω 2
F 4 = h 3 h 0 T 0 ( s 3 s 0 ) [ h 4 h 0 T 0 ( s 4 s 0 ) ]
where MF4 is the EIL of high-pressure turbine, F 4 is the fuel and P 4 is the product of high-pressure turbine in a fault condition, F4 is the fuel and P4 is the product of high-pressure turbine in normal condition.
The calculation equation of the EIL of the low-pressure turbine is:
M F 5 = P 5 ( F 5 P 5 F 5 P 5 )
P 5 = 1 2 J L C L T ω 2
F 5 = h 4 h 0 T 0 ( s 4 s 0 ) [ h 5 h 0 T 0 ( s 5 s 0 ) ]
where MF5 is the EIL of the low-pressure turbine, F 5 is the fuel and P 5 is the product of low-pressure turbine in a fault condition, F5 is the fuel and P5 is the product of low-pressure turbine in normal condition.
The calculation equation of the EIL of power turbine is:
M F 6 = P 6 ( F 6 P 6 F 6 P 6 )
P 6 = W n e t
F 6 = h 6 h 0 T 0 ( s 6 s 0 )
where MF6 is the EIL of power turbine, F 6 is the fuel and P 6 is the product of power turbine in a faulty condition, F6 and P6 are the fuel and product of power turbine in normal condition.
The change of unit exergy consumption reflects the change of component exergy efficiency, which defines the internal EIL of the equipment. This index is a problem that needs to be explored for the variation law of the equipment in case of failure and the variation law under the influence of multiple boundary conditions. This problem will be discussed in detail in Section 4.

2.4. Gas Turbine Exergy Loss Analysis Under Normal Conditions

First, the correlation matrix is introduced. The correlation matrix is the matrix connecting each exergy flow and each component in the system. If the system includes m component and n exergy flow, its correlation matrix is A(m × n), and its element aij is expressed by the following method. When the exergy flow is input into the component i, it is recorded as aij = 1; when the exergy flow is output from the component, it is recorded as aij = −1; when neither input nor output, it is recorded as aij = 0. Through the correlation matrix, the characteristics of the whole system can be described. After introducing the correlation matrix, the exergy balance of the system can be written as
A × E = I
where E is the exergy flow vector [0, P1, P2, F3, PJ, B3, F5, F6, F4, F1, F2, P6]; I is the exergy loss [I1, I2, …, I12] of each component. Through the correlation matrix A and exergy flow direction E obtained from the above equations, and through exergy balance expression, exergy loss I is obtained, where A is as shown in the equation.
A = [ 0 1 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 1 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 1 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 ]
Thus, the EIL of each component can be obtained. According to the above equations, a gas turbine EIL model is established, which will be verified in Section 4.

3. Gas Path Fault Diagnosis Method Based on EIL

The traditional gas path fault diagnosis method is based on the first law of thermodynamics, which detects the malfunction of the component by the deviation of gas path measured variables. It can be from Figure 3, the components are interrelated, that is, result in the strong coupling effect for measured variables and the fault may not be effectively identified [18]. EIL is based on the second law of thermodynamics, which is from a comprehensive sight of the system to detect efficiency deviations and identify the causes of performance degradation, and may solve the parameter coupling problem of traditional gas path analysis method. A gas path fault diagnosis algorithm based on EIL is proposed, and its fault diagnosis process is shown in Figure 5, which consists the following steps:
Step 1: The measured temperature variables T were acquired from the monitoring and control system of the marine gas turbine, where T = [ T 1 , T 2 , T 4 , T 5 , T 6 ] , T 1 is the outlet temperature of low-pressure compressor, T 2 is the outlet temperature of high-pressure compressor, T 4 is the outlet temperature of high-pressure turbine, T 5 is the outlet temperature of low-pressure turbine, T 6 is the outlet temperature of power turbine. The Load is the power output of the gas turbine; in this paper, we use the operating points to present the rated power. T0 and P0 are the environment parameters.
Step 2: The measured temperature variables T under the normal condition are estimated by the healthy estimation model that is established by back a propagation neural networks [33]. For the gas turbine healthy estimation model, the inputs are the environment parameters (T0, P0) and Load.
Step 3: The endogenous irreversible loss MF of the gas turbine components under given conditions are calculated by the EIL model, which is presented in Section 2.
Step 4: The EIL model output describes the characteristics of the gas turbine under normal condition and different faulty conditions, and the diagnostic rule was obtained by statical analysis. Therefore, in this paper, a gas path fault reasoning algorithm is proposed, and its flowchart is shown in Figure 6.
In this process, when the endogenous irreversible loss MF input, Rule 0 is used to detect whether the current condition is normal or not. If it is Y, the output C0 = 1, and the current condition is normal. If it is N, it indicates that there is a fault, C0 = 0, and then the following n diagnostic rules will be executed in parallel. For example, if the MF complies with Rule 1, then the diagnostic result of Ruel 1 is C1 = 1, or else if all other rule output is 0, then the current condition is the first fault.

4. Results and Discussion of Fault Diagnosis

In this section, taking a marine three-shaft gas turbine as an example, the simulation results of the EIL under typical gas path fault are obtained, and then a simulation case was carried out to verify the fault diagnosis method based on EIL.

4.1. Exergy Loss Analysis of Marine Gas Turbine Under Normal Condition

The marine three-shaft gas turbine was divided into eight process groups, including six components and two virtual process groups. According to the productive structure of a marine three-shaft gas turbine, the marine gas turbine EIL model was established in MATLAB/Simulink, and the step size of the model was 0.2 s. The exergy loss of each process component under different operating conditions were calculated. In this simulation case, T0 = 20 °C P0 = 101.325 kPa, and Load was set to 0.5, 0.6, 0.7, 0.8, and 0.9, respectively, where 0.6 means 60% of rated power. Simulation results of exergy loss of marine three-shaft gas turbine components are shown in Table 1, and the unit is kilojoules per kilogram (kJ/kg).
It can be seen from the Table 1 that the exergy losses of components are different under the same operating condition, the exergy loss of combustion chamber is the highest, which is because the exergy loss is very large in the combustion process, and the exergy loss of power turbine is also relatively high. Therefore, the simulation results are in accordance with the thermodynamic law. The degree of exergy loss for a component only increases slightly with the increase of operating conditions, which indicates that exergy loss can be used to characterize the impact of faults on components more stable, and this advantage is helpful for fault isolation. The junction point and breakpoint are virtual components, then the exergy loss of them is 0.

4.2. Fault Reasoning Rules of the Typical Gas Path Fault Conditions

4.2.1. Simulation of Gas Turbine EIL Under Fault Condition

The magnitude of the EIL is mainly related to the fault of the system itself, and many scholars regard it as an important condition of fault isolation. Therefore, the variation law of the EIL under the complex boundary conditions, which is the combination of environment temperature and operating conditions, was studied and analyzed on the marine gas turbine EIL model, and the EIL reasoning rule of typical gas path fault is obtained.
A total of 35 boundary conditions were set in Figure 7 and Figure 8, consisting of five operating conditions (0.5–0.9) and seven temperature conditions (0–30 °C, 5 °C steps). The simulation step of the exergy balance simulation model was set to 0.2 s and simulation time set to 1050 s, that is, 5250 simulation experiments were performed for a typical fault condition, and 11 typical fault conditions, including normal condition and 10 fault conditions, are shown in Table 2.
In Table 2, Ci represents a kind of component fault state. Where C0 represents normal condition, C1 represents a 5% decrease in low-pressure compressor efficiency, C2 represents a 5% decrease in low-pressure compressor flow, C3 represents a 5% decrease in high-pressure compressor efficiency, C4 represents a 5% decrease in high-pressure compressor flow, C5 represents a 5% decrease in high-pressure turbine efficiency, and C6 represents 5% decreases in high-pressure turbine flow, C7 represents a 5% decrease in low-pressure turbine efficiency, C8 represents a 5% decrease in low-pressure turbine flow, C9 represents a 5% decrease in power turbine efficiency, and C10 represents a 5% decrease in power turbine flow.

4.2.2. Variation Law of Component EIL Under Typical Fault Condition

It can be seen from Figure 5 that there are six temperature-measured variables in the gas turbine monitoring and control system. Therefore, there are four component EIL that can be monitored in practice, that is the low-pressure compressor, the high-pressure compressor, the low-pressure turbine, and the power turbine. The fault factors were implanted in the EIL model to get the distribution of the EIL of each component. Based on the typical fault simulation result in Section 4.2.1, the variation laws of the four component EIL results are shown in Figure 9.
The maximum value, minimum value, and standard deviation of each component EIL under typical fault condition were obtained. Take C1 (5% decrease in low-pressure compressor efficiency) as an example, the maximum value, minimum value, and standard deviation of the EIL under 35 boundary conditions are shown in Table 3.
From Figure 9, it can clearly be seen that the distribution range of the EIL of each component is unique when different faults occurred. Therefore, it is feasible to use the EIL for fault detection and isolation of the marine three-shaft gas turbine.

4.2.3. Gas Path Fault Reasoning Rules

Firstly, the false alarm rate Fr and missing alarm rate Mr are introduced as fault diagnosis criteria.
F r = M R T × 100 %
M r = N T × 100 %
where M is the number of the false alarm, N is the number of missing alarm, T is the number of experiment samples for each fault pattern, and R is the total number of experiment samples.
It is necessary to judge whether there is a fault in the system. When there is no fault, the EIL of the marine gas turbine component should be zero in theory. However, in practice, due to the noise, the EIL of the system is not zero, but a very small number close to zero. Therefore, for the reasoning rule of the normal condition, the setting of the threshold value of the EIL needs to be discussed.
a b s ( M F i ) < X
where i represents the components of the marine gas turbine, and X represents the value of the threshold. Suppose X equals 0.1, 0.2, 0.3, 0.4, and 0.5 respectively, and the false alarm rate and missing alarm rate are shown in Table 4, respectively.
It can be seen from the table that the false alarm rate Fr has a slight downward trend with increasing the threshold, while the missing alarm rate Mr is zero when X equals 0.2 or 0.3.
On the basis of the gas path fault diagnosis method introduced in Section 3, according to the EIL distribution of components under 10 typical fault conditions in Figure 9, the fault reasoning rules are shown in Table 5.
According to Figure 6, IF and ELSE-IF logic statements are used to fault reasoning, and the fault diagnosis result is expressed in the fault vector C.

4.3. Fault Diagnosis of Marine Gas Turbine

In this section, using the marine gas turbine model to present the actual marine gas turbine [33], which was established in Matlab/Simulink, and the simulation method is the fourth-order ode14x (extrapolation with fixed time step), the simulation step is 0.2 s. In the test case, the gas turbine works under the transient condition, the operating condition is increased from 0.5 to 0.9 in 500 s with the variable environment temperature that is between 0 and 30 °C, as shown in Figure 10 and Figure 11.
Suppose gas turbine works in 30 s under normal condition C 0 , then a fault occurred for 20 s. Ten typical faulty conditions C 1 , C 2 , , C 10 occurred separately in sequence. The fault simulation setting is shown in Figure 12. Therefore, the total number of test samples is 2501, the number of normal test samples is 1001, and the number of test samples for each fault is 150.
The measured variables under the normal condition are on-line estimate by the healthy estimation model, then using the EIL model to calculate the EIL of each component under this test case, and the results of the EIL are shown in Figure 13.
Figure 13 shows the change process of the EILs of the low-pressure compressor, high-pressure compressor, low-pressure turbine, and power turbine, and the EIL will change abruptly at the moment of gas path fault implantation.
Finally, the MFs of component EIL input the fault reasoning algorithm. Rule 0 is used to detect the current status of the marine gas turbine, whether it is normal or not. The diagnosis result is μ 0 , 1 represents the normal condition, and 0 represents the faulty condition. When a fault is detected, ten typical fault reasoning rules execute in parallel to isolate which fault occurred, the fault reasoning results are μ 1 ~ μ 10 , which is the value of element C 1 , , C 10 of fault vector C. The fault reasoning results are shown in Figure 14, and it shows that the marine gas turbine diagnosis method based on EIL can diagnose the gas path fault correctly. The EIL has good sensitivity to the gas path fault, the reasoning rule will change in time when the hypothesis fault occurred. At the same time, through experiments, it is found that missing alarms generally occur at the switching time of normal condition and fault condition, so the fault detection time is introduced, which is the product of the time step and the missing alarm. The false alarm, missing alarm, and detection time are shown in Table 6.
In Table 6, the total number of experiment samples R is 2501. The performance of fault detection of the proposed gas path fault diagnosis method based on EIL can be seen from the false alarm rate and missing alarm rate of normal condition C0, the number of normal condition experiment samples is 1001, the number of false alarm is 12, and the number of missing alarm is 16, so the false alarm rate is 0.08% and the missing alarm rate is 1.6%. When the marine gas turbine returns to normal condition, the maximum detection time needs 4 time steps, that is, 0.8 s. The simulation results show that the performance of the gas path fault diagnosis method can detect fault quickly and accurately.
The performance of fault isolation of the proposed gas path fault diagnosis based on EIL can be seen from the false alarm rate and missing alarm rate of the fault condition C1, C2, …, C10. Although the missing alarm rate is slightly higher, the proposed gas path fault diagnosis method can isolate fault accurately. The false alarm rate is less than 1% which shows that the diagnostic reasoning rules based on EIL are robust under complex operating conditions and environments.
The missing alarm of C8 and C10 is high, because the transition time from the normal condition to fault condition of the marine gas turbine model is long in the simulation test.

5. Conclusions

In this paper, a gas path fault diagnosis method based on EIL has been presented to detect and isolate the gas path faults of marine gas turbines. The EIL of component models were established to characterize exergy loss under the normal condition and typical gas path fault condition. The EIL is sensitive to gas path fault, and it is not affected by the change of operating condition and environment. Therefore, the diagnostic reasoning rules based on EIL are robust, and are helpful for detecting and isolating gas path faulty components.
Simulation case studies on a three-shaft marine gas turbine were conducted, and the performance of the proposed method for the detection and isolation of typical gas path fault was analyzed. The simulation results show that the proposed EIL-based gas path fault diagnosis method detect and isolate gas path fault accurately.
In this paper, the feasibility of the gas path fault diagnosis based on EIL was verified by single gas path fault. In the future, we will improve the performance of the proposed method under transient process. Furthermore, we will continually evaluate the multiple gas path fault diagnosis performance of the proposed method and also study hybrid diagnostic approaches combining EIL with artificial intelligence algorithms.

Author Contributions

This research was completed through a collaboration of all authors. Y.C. and J.L. proposed the fault diagnosis based on EIL and wrote the original manuscript; S.L. was the team leader of this work and responsible for coordination; G.H., X.L., and Y.C. designed the case studies and analyzed the results.

Funding

This research was funded by the National Science and Technology Major Project (2017-I-0007-0008) and the Fundamental Research Funds for the Central Universities (HEUCFP201722).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Volponi, A.J. Gas Turbine Engine Health Management: Past, Present, and Future Trends. J. Eng. Gas Turbines Power 2014, 136, 051201. [Google Scholar] [CrossRef]
  2. Tahan, M.; Tsoutsanis, E.; Muhammad, M. Performance-based health monitoring, diagnostics and prognostics for condition-based maintenance of gas turbines: A review. Appl. Energy 2017, 198, 122–144. [Google Scholar] [CrossRef] [Green Version]
  3. Li, Y.G. Gas turbine performance and health status estimation using adaptive gas path analysis. J. Eng. Gas. Turbines Power 2010, 132, 041701. [Google Scholar] [CrossRef]
  4. Ying, Y.; Cao, Y.P.; Li, S. Study on gas turbine engine fault diagnostic approach with a hybrid of gray relation theory and gas-path analysis. Adv. Mech. Eng. 2016, 8, 1687814015627769. [Google Scholar] [CrossRef] [Green Version]
  5. Simon, D.L.; Bird, J.; Davison, C.; Volponi, A.; Iverson, R.E. Bench marking gas path diagnostic methods: A public approach. In Proceedings of the ASME Turbo Expo 2008: Power for Land, Sea, and Air, Berlin, Germany, 9–13 June 2008; pp. 325–336. [Google Scholar]
  6. Kyriazis, A.; Mathioudakis, K. Gas Turbine Fault Diagnosis Using Fuzzy-Based Decision Fusion. J. Propuls. Power 2009, 25, 335–343. [Google Scholar] [CrossRef]
  7. Amare, F.D.; Gilani, S.I.; Aklilu, B.T. Two-shaft stationary gas turbine engine gas path diagnostics using fuzzy logic. J. Mech. Sci. Technol. 2017, 31, 5593–5602. [Google Scholar] [CrossRef]
  8. Zaidan, M.A.; Mills, A.R.; Harrison, R.F.; Fleming, P.J. Gas turbine engine prognostics using Bayesian hierarchical models: A variational approach. Mech. Syst. Sig. Proc. 2016, 70, 120–140. [Google Scholar] [CrossRef]
  9. Zaidan, M.A.; Mills, A.R.; Harrison, R.F.; Fleming, P.J. Bayesian hierarchical models for aerospace gas turbine engine prognostics. Expert Syst. Appl. 2015, 42, 539–553. [Google Scholar] [CrossRef]
  10. Romessis, C.; Stamatis, A.; Mathioudakis, K. Setting up a belief network for turbofan diagnosis with the aid of an engine performance model. ISABE Pap. 2001, 1032, 19–26. [Google Scholar]
  11. Cao, Y.P.; Li, S.Y.; Yi, S.; Zhao, N.B. Fault diagnosis of a gas turbine gas fuel system using a self-organizing network. Adv. Sci. Lett. 2012, 8, 386–392. [Google Scholar] [CrossRef]
  12. Talaat, M.; Gobran, M.H.; Wasfi, M. A hybrid model of an artificial neural network with thermodynamic model for system diagnosis of electrical power plant gas turbine. J. Eng. Appl. Artif. Intell. 2018, 68, 222–235. [Google Scholar] [CrossRef]
  13. Zedda, M.; Singh, R. Gas Turbine Engine and Sensor Fault Diagnosis Using Optimization Techniques. J. Propuls. Power 2002, 18, 1019–1025. [Google Scholar] [CrossRef]
  14. Alfredo, G.; Raniero, S. A multi-variable multi-objective methodology for experimental data and thermodynamic analysis validation: An application to micro gas turbines. J. Appl. Therm. Eng. 2018, 134, 501–512. [Google Scholar] [CrossRef]
  15. Meskin, N.; Naderi, E.; Khorasani, K. A Multiple Model-Based Approach for Fault Diagnosis of Jet Engines. IEEE Trans. Control Syst. Technol. 2013, 21, 254–262. [Google Scholar] [CrossRef]
  16. Yang, Q.; Li, S.; Cao, Y. A Gas Path Fault Contribution Matrix for Marine Gas Turbine Diagnosis Based on a Multiple Model Fault Detection and Isolation Approach. Energies 2018, 11, 3316. [Google Scholar] [CrossRef] [Green Version]
  17. Keshavarzian, S.; Rocco, M.V.; Colombo, E. Thermoeconomic diagnosis and malfunction decomposition: Methodology improvement of the Thermoeconomic Input-Output Analysis (TIOA). Energy Convers. Manag. 2018, 157, 644–655. [Google Scholar] [CrossRef]
  18. Iacentino, A.; Catrini, P. Assessing the Robustness of Thermoeconomic Diagnosis of Fouled Evaporators: Sensitivity Analysis of the Exergetic Performance of Direct Expansion Coils. Entropy 2016, 18, 85. [Google Scholar] [CrossRef] [Green Version]
  19. Direk, M.; Mert, M.S. Comparative and Exergetic Study of a Gas Turbine System with Inlet Air Cooling. Teh. Vjesn. Tech. Gaz. 2018, 25, 306–311. [Google Scholar] [CrossRef] [Green Version]
  20. Fallah, M.; Siyahi, H.; Ghiasi, R.A.; Mahmoudi, S.M.S.; Yari, M.; Rosen, M.A. Comparison of different gas turbine cycles and advanced exergy analysis of the most effective. Energy 2016, 116, 701–715. [Google Scholar] [CrossRef]
  21. Haseli, Y.; Dincer, I.; Naterer, G.F. Exergy analysis of a combined fuel cell and Gas Turbine Power Plant with intercooling and reheating. Int. J. Exergy 2010, 7, 211–231. [Google Scholar] [CrossRef]
  22. Ibrahim, T.K.; Basrawi, F.; Awad, O.I.; Abdullah, A.N.; Najafi, G.; Mamat, R.; Hagos, F.Y. Thermal performance of gas turbine power plant based on exergy analysis. Appl. Therm. Eng. 2017, 115, 977–985. [Google Scholar] [CrossRef]
  23. Khaliq, A.; Choudhary, K. Exergy analysis of the regenerative gas turbine cycle using absorption inlet cooling and evaporative aftercooling. J. Energy Inst. 2009, 82, 159–167. [Google Scholar] [CrossRef]
  24. Peng, S.; Hong, H. Exergy analysis of solar gas turbine system coupled with Kalina cycle. Int. J. Exergy 2015, 18, 192–213. [Google Scholar] [CrossRef]
  25. Sohret, Y.; Ekici, S.; Altuntas, O.; Hepbasli, A.; Karakoc, T.H. Exergy as a useful tool for the performance assessment of aircraft gas turbine engines: A key review. Prog. Aerosp. Sci. 2016, 83, 57–69. [Google Scholar] [CrossRef]
  26. Cross, A.J.; Longden, A.; Owen, F. A Critical Review of the Thermoeconomic Diagnosis Methodologies for the Location of Causes of Malfunctions in Energy Systems. J. Energy Resour. Technol. 2003, 128, 345–354. [Google Scholar] [CrossRef]
  27. Verda, V.; Baccino, G. Thermoeconomic Diagnosis Applied to the Transient Operation of a Microturbine. In Proceedings of the ASME 2012 International Mechanical Engineering Congress and Exposition, Houston, TX, USA, 9–15 November 2012; pp. 1579–1588. [Google Scholar]
  28. Oh, H.S.; Lee, Y.; Kwak, H.Y. Diagnosis of Combined Cycle Power Plant Based on Thermoeconomic Analysis:A Computer Simulation Study. Entrop 2017, 19, 643. [Google Scholar] [CrossRef] [Green Version]
  29. Massardo, A.F.; Scialo, M. Thermoeconomic Analysis of Gas Turbine Based Cycles. J. Eng. Gas Turbines Power 1999, 122, 664–671. [Google Scholar] [CrossRef]
  30. Yan, Q.Y.; Yan, Q.S. Analysis of influence factors on irreversible loss and optimization in heat exchanger. In Proceedings of the 3rd International Symposium on Heat Transfer Enhancement and Energy Conservation, Guangzhou, China, 12–15 January 2004; Volume 1–2. [Google Scholar]
  31. Chen, L.E.; Zhu, X.Q.; Sun, F.; Wu, C. Exergy-based ecological optimization for a generalized irreversible Carnot heat-pump. Appl. Energy 2007, 84, 78–88. [Google Scholar] [CrossRef]
  32. Cheng, X.T.; Liang, X.G. Entransy analyses of heat-work conversion systems with inner irreversible thermodynamic cycles. Chin. Phys. B 2015, 24. [Google Scholar] [CrossRef]
  33. Cao, Y.; He, Y.; Yu, F.; Du, J.; Li, S.; Yang, Q.; Liu, R. A Two-Layer Multi-Model Gas Path Fault Diagnosis Method. In Proceedings of the ASME Turbo Expo 2018: Turbomachinery Technical Conference and Exposition. Volume 6: Ceramics; Controls, Diagnostics, and Instrumentation; Education; Manufacturing Materials and Metallurgy, Oslo, Norway, 11–15 June 2018; American Society of Mechanical Engineers Digital Collection: New York, NY, USA, 2018. [Google Scholar]
  34. Torres, C.; Valero, A.; Serra, L.; Royo, J. Structural theory and thermoeconomic diagnosis Part 1. On malfunction and dysfunction analysis. Energy Convers. Manag. 2002, 43, 1503–1518. [Google Scholar] [CrossRef]
  35. Verda, V.; Serra, L.; Valero, A. Thermoeconomic diagnosis: Zooming strategy applied to highly complex energy systems. Part 2: On the choice of the productive structure. J. Energy Resour. Technol. Trans. 2005, 127, 50–58. [Google Scholar] [CrossRef]
Figure 1. Production relationship between fuel in normal/fault condition.
Figure 1. Production relationship between fuel in normal/fault condition.
Energies 12 04677 g001
Figure 2. The layout of a marine three-shaft gas turbine.
Figure 2. The layout of a marine three-shaft gas turbine.
Energies 12 04677 g002
Figure 3. The physical structure of the marine three-shaft gas turbine.
Figure 3. The physical structure of the marine three-shaft gas turbine.
Energies 12 04677 g003
Figure 4. Productive structure of the marine three-shaft gas turbine.
Figure 4. Productive structure of the marine three-shaft gas turbine.
Energies 12 04677 g004
Figure 5. Fault diagnosis process of the marine gas turbine in operation.
Figure 5. Fault diagnosis process of the marine gas turbine in operation.
Energies 12 04677 g005
Figure 6. The flowchart of the fault reasoning algorithm.
Figure 6. The flowchart of the fault reasoning algorithm.
Energies 12 04677 g006
Figure 7. The setting of operating conditions.
Figure 7. The setting of operating conditions.
Energies 12 04677 g007
Figure 8. The setting of environment temperature.
Figure 8. The setting of environment temperature.
Energies 12 04677 g008
Figure 9. Distribution law of the EIL of various systems under marine gas turbine failure.
Figure 9. Distribution law of the EIL of various systems under marine gas turbine failure.
Energies 12 04677 g009
Figure 10. The operating condition setting of marine gas turbine.
Figure 10. The operating condition setting of marine gas turbine.
Energies 12 04677 g010
Figure 11. The ambient temperature setting of marine gas turbine.
Figure 11. The ambient temperature setting of marine gas turbine.
Energies 12 04677 g011
Figure 12. Settings of simulation fault.
Figure 12. Settings of simulation fault.
Energies 12 04677 g012
Figure 13. Component EIL change of marine gas turbine under simulated fault.
Figure 13. Component EIL change of marine gas turbine under simulated fault.
Energies 12 04677 g013
Figure 14. Diagnosis results of the marine gas turbine system.
Figure 14. Diagnosis results of the marine gas turbine system.
Energies 12 04677 g014
Table 1. Simulation results of exergy loss of marine three-shaft gas turbine components.
Table 1. Simulation results of exergy loss of marine three-shaft gas turbine components.
Operating ConditionLCHCCCHTLTPTJB
0.516.5915.62247.1569.5916.45169.7500
0.617.2115.98257.8473.5117.14182.6900
0.718.1716.34267.8977.2617.78196.2000
0.818.8616.78277.0480.7218.39209.2100
0.919.6117.05285.5883.9518.97221.6800
Table 2. Typical fault models of marine gas turbine.
Table 2. Typical fault models of marine gas turbine.
CaseLCHCHTLTPT
Δ η L C Δ G L C Δ η H C Δ G H C Δ η H T Δ G H T Δ η L T Δ G L T Δ η P T Δ G P T
C00000000000
C1−5000000000
C20−500000000
C300−50000000
C4000−5000000
C50000−500000
C600000−50000
C7000000−5000
C80000000−500
C900000000−50
C10000000000−5
Table 3. The variation law of the EIL under typical fault condition C1.
Table 3. The variation law of the EIL under typical fault condition C1.
ParameterLCHCLTPT
MF_max6.480.010.1113.16
MF_min5.38−0.38−0.049.50
MF_std0.270.020.010.50
Table 4. Relationship between the threshold and diagnostic criteria.
Table 4. Relationship between the threshold and diagnostic criteria.
XFrMr
0.16.52%0.04%
0.25.84%0%
0.35.48%0%
0.45.12%0.04%
0.54.880%0.08%
Table 5. Fault reasoning rules of the marine three-shaft gas turbine.
Table 5. Fault reasoning rules of the marine three-shaft gas turbine.
NumberConditionFault Vector
Rule 0 0 | M F ( i ) | < 0.3 [1 0 0 0 0 0 0 0 0 0 0]
Rule 1 5.38 M F L C 6.48 [0 1 0 0 0 0 0 0 0 0 0]
Rule 2 0.001 < M F L C 0.77 & 0.001 < M F P T 1.55 & 0.07 M F H C 0.01 [0 0 1 0 0 0 0 0 0 0 0]
Rule 3 4.40 M F H C 5.29 [0 0 0 1 0 0 0 0 0 0 0]
Rule 4 M F L C 0.001   &   0.64 M F H C 1.11   &   0.04 M F L T 0.01   &   0.63 M F P T 1.70 [0 0 0 0 1 0 0 0 0 0 0]
Rule 5 9.67 M F P T 13.16 [0 0 0 0 0 1 0 0 0 0 0]
Rule 6 M F L C > 0.001 & M F H C < 0.001 & 3.92 M F L T 2.67 & 4.23 M F P T 1.96 [0 0 0 0 0 0 1 0 0 0 0]
Rule 7 3.67 M F L T 4.36 [0 0 0 0 0 0 0 1 0 0 0]
Rule 8 M F L C < 0.001 & M F H C < 0.001 & 1.43 M F L T 1.08 & 6.05 M F P T 2.50 [0 0 0 0 0 0 0 0 1 0 0]
Rule 9 16.30 M F P T 26.21 [0 0 0 0 0 0 0 0 0 1 0]
Rule 10 0.43 < M F L C < 1.50 & 0.05 < M F H C 0.22 & 1.51 < M F L T 2.01 & 1.77 < M F P T 3.77 [0 0 0 0 0 0 0 0 0 0 1]
Table 6. Results of false alarm, missing alarm, and detection time.
Table 6. Results of false alarm, missing alarm, and detection time.
ModeTR-TMNFalse Alarm RateMissing Alarm RateDetection Time
C 0 1001150012160.08%1.60%0.8 s (max)
C 1 1502351030.00%2.00%0.6 s
C 2 1502351180.04%5.33%1.6 s
C 3 1502351000.00%0.00%0 s
C 4 15023510110.00%7.33%2.2 s
C 5 150235115120.64%8.00%2.4 s
C 6 15023510120.00%8.00%2.4 s
C 7 15023512070.85%4.67%1.4 s
C 8 15023510220.00%14.67%4.4 s
C 9 1502351110.04%0.67%0.2 s
C 10 15023510200.00%13.33%4 s

Share and Cite

MDPI and ACS Style

Cao, Y.; Luan, J.; Han, G.; Lv, X.; Li, S. A Marine Gas Turbine Fault Diagnosis Method Based on Endogenous Irreversible Loss. Energies 2019, 12, 4677. https://doi.org/10.3390/en12244677

AMA Style

Cao Y, Luan J, Han G, Lv X, Li S. A Marine Gas Turbine Fault Diagnosis Method Based on Endogenous Irreversible Loss. Energies. 2019; 12(24):4677. https://doi.org/10.3390/en12244677

Chicago/Turabian Style

Cao, Yunpeng, Junqi Luan, Guodong Han, Xinran Lv, and Shuying Li. 2019. "A Marine Gas Turbine Fault Diagnosis Method Based on Endogenous Irreversible Loss" Energies 12, no. 24: 4677. https://doi.org/10.3390/en12244677

APA Style

Cao, Y., Luan, J., Han, G., Lv, X., & Li, S. (2019). A Marine Gas Turbine Fault Diagnosis Method Based on Endogenous Irreversible Loss. Energies, 12(24), 4677. https://doi.org/10.3390/en12244677

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop