Investigation on the Insulation Resistance Characteristics of Low Voltage Cable
Abstract
:1. Introduction
2. Arrhenius Equation
3. Experimental Methods and Results
3.1. Characteristics of Cable Insulation Resistance through Contact with an External Flame
3.2. Characteristics of Insulation Resistance According to Cable Lifetime
3.3. Insulation Resistance of the Cable Due to Over-Current
4. Conclusions
Author Contributions
Funding
Conflicts of Interest
References
- National Fire Data System in the National Fire Agency. Fire Statistics Data Tables; National Fire Data System in the National Fire Agency: Sejong, Korea, 2016. [Google Scholar]
- Kang, S.-D.; Kim, J.-H.; Kim, J.-H. A Study on the Insulation Resistance in Cable with Rising Temperature. J. Korean Inst. Illum. Electr. Install. Eng. 2018, 32, 72–77. [Google Scholar]
- Ghorbani, H.; Abbasi, A.; Jeroense, M.; Gustafsson, A.; Saltzer, M. Electrical characterization of extruded DC cable insulation—The challenge of scaling. IEEE Trans. Dielectr. Electr. Insul. 2017, 24, 1465–1475. [Google Scholar] [CrossRef]
- Motori, A.; Sandrolini, F.; Montanari, C.G. A contribution to the study of aging of XLPE insulated cable. IEEE Trans. Power Deliv. 1991, 6, 34–42. [Google Scholar] [CrossRef]
- Lee, J.B.; Jung, Y.H. An amendment of the VLF tanδ criteria to improve the diagnostic accuracy of the XLPE-insulated power cables. Trans. Korean Inst. Electr. Eng. 2010, 59, 1644–1651. [Google Scholar]
- Nam, Y.H.; Choi, K.H.; Park, M.G. Power cable maintenance using cable cure based on isothermal relaxation current measurement. J. Korean Soc. Urban Railw. 2016, 4, 465–470. [Google Scholar]
- Liu, Y.; Cao, X. Insulation performance evaluation of HV AC/DC XLPE cables by 0.1 Hz tan δ test on circumferentially peeled samples. IEEE Trans. Dielectr. Electr. Insul. 2017, 24, 3941–3950. [Google Scholar] [CrossRef]
- Polanský, R.; Polanska, M. Testing of the fire-proof functionality of cable insulation under fire conditions via insulation resistance measurements. Eng. Fail. Anal. 2015, 57, 334–349. [Google Scholar] [CrossRef]
- Wang, J.; Shu, Z.-J.; Chen, Z. The protective effect of a fire-retardant coating on the insulation failure of PVC cable. Eng. Fail. Anal. 2013, 34, 1–9. [Google Scholar] [CrossRef] [Green Version]
- Polanska, M.; Prosr, P.; Polanský, R. Changes of insulation resistance of fire resistant cable under fire conditions. In Proceedings of the 2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Ann Arbor, MI, USA, 18–21 October 2015; pp. 278–281. [Google Scholar]
- Um, K.H. Design of measuring system for insulation resistance and humidity in high-power XLPE cables operation and the relationship between insulation resistance and humidity in the oversheath. J. Inst. Internet Broadcast. Commun. 2016, 16, 179–184. [Google Scholar] [CrossRef]
- Guastavino, F.; Coletti, G.; Ratto, A.; Torello, E.; Michelato, P.; Celentano, M.; Zucchelli, A. An experimental study about the fire resistance of low voltage cables. In Proceedings of the Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, Toronto, ON, Canada, 11–14 June 2006; pp. 174–177. [Google Scholar]
- Um, K.-H.; Lee, K.-W. A Study on Cable Lifetime Evaluation Based on Characteristic Analysis of Insulation Resistance by Acceleration Factor of the Arrhenius Equation. J. Inst. Internet Broadcast. Commun. 2014, 14, 231–236. [Google Scholar] [CrossRef]
- IEC 60331-1. Tests for Electric Cables under Fire Condition—Circuit Integrity; IEC: Geneva, Switzerland, 2018. [Google Scholar]
- Poirier, M.; Stonkus, D.; Benson, S. Condition monitoring of nuclear cables using the indenter modulus. In Proceedings of the 17th Annual Conference, Canadian Nuclear Society, Fredericton, NB, Canada, 9–12 June 1996; pp. 1–13. [Google Scholar]
Nominal Sectional Area (mm2) | Conductor Thickness (mm) | Insulator | Outer Diameter (mm) | Allowable Current (A) | Allowable Temperature (°C) | |
---|---|---|---|---|---|---|
TFR-8 cable | 2.5 | 2.1 | PVC, XLPE, Mica tape, Filer | 14 | 30 | 830 |
VCTF cable | 2.5 | 2.1 | PVC | 11.4 | 30 | 70 |
10 years | 20 years | 30 years | 40 years | |
---|---|---|---|---|
: Accelerated degradation time | 22 h | 44 h | 67 h | 89 h |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Kang, S.-D.; Kim, J.-H. Investigation on the Insulation Resistance Characteristics of Low Voltage Cable. Energies 2020, 13, 3611. https://doi.org/10.3390/en13143611
Kang S-D, Kim J-H. Investigation on the Insulation Resistance Characteristics of Low Voltage Cable. Energies. 2020; 13(14):3611. https://doi.org/10.3390/en13143611
Chicago/Turabian StyleKang, Sin-Dong, and Jae-Ho Kim. 2020. "Investigation on the Insulation Resistance Characteristics of Low Voltage Cable" Energies 13, no. 14: 3611. https://doi.org/10.3390/en13143611
APA StyleKang, S.-D., & Kim, J.-H. (2020). Investigation on the Insulation Resistance Characteristics of Low Voltage Cable. Energies, 13(14), 3611. https://doi.org/10.3390/en13143611