1. Introduction
In conventional electro-hydraulic systems, analogue spool valves, including both proportional and servovalves, play a crucial role, as they act as the interface between electric signals and hydraulic power [
1,
2]. These valves, functioning as directional control valves, regulate the fluid flow directed towards hydraulic actuators in a wide range of applications, including robotics [
3], flight simulations [
4], gas turbine engines [
5], and earthmoving equipment [
6]. Despite their notable performance characteristics, such as excellent accuracy [
7], precise controllability [
8], and rapid response times [
9], these valves have been criticized for their susceptibility to impurities and relatively high cost [
10,
11]. Moreover, proportional and servovalves are known for their significant energy losses, which are mainly attributed to the spool architecture [
12]. This design characteristic results in high pressure drops, which in turn lead to elevated power consumption, accounting for 60% of the overall losses in conventional hydraulic systems [
13]. In [
14], the authors determined, with a simple calculation, that a medium-sized spool valve with a pressure drop of 30 bar and a flow rate of 60 L/min, would dissipate approximately 7 kW of power. Additionally, the energy efficiency of conventional hydraulic systems is significantly influenced by the dynamics of the fluid flow within its various components. The impact of hydrodynamic processes on fluid flow characteristics and their influence on system energy efficiency has recently been explored in [
15].
In recent years, there has been a significant increase in interest in the emerging field of digital hydraulic technology. This novel technology aims to enhance the energy efficiency of hydraulic systems through the implementation of digital and discrete control techniques [
16,
17,
18]. Specifically, these digital and discrete methods are used to actively and intelligently control the output of the system by employing robust and low-cost on/off valves [
19]. The remarkable results achieved in various applications, including aircraft brake systems [
20], aircraft actuators [
21], aircraft fuel systems [
22], construction machinery [
23,
24], conveyors [
25], and wave energy recovery systems [
26], have demonstrated that digital hydraulic technology has the potential to replace conventional hydraulic technology for the efficient realization of “Industry 4.0” hydraulic systems [
27].
The higher energy efficiency of digital hydraulic systems compared to conventional hydraulic systems is attributed to the fact that digital hydraulic valves operate in an on/off manner and may not require a spool for flow adjustment [
28]. Consequently, digital hydraulic valves can have the same architecture as that of poppet valves. The poppet valve design, characterized by a larger flow area and absence of leakage, enables efficient control, minimizes energy losses, and thereby improves the performance of the overall hydraulic system [
14].
Among the various digital and discrete techniques used to control digital hydraulic valves, pulse width modulation (PWM) stands out as one of the most significant [
29,
30]. When PWM techniques are employed, digital hydraulic valves are commonly known as high frequency switching digital hydraulic valves (HFSVs) [
31].
An HFSV operates by receiving an input pulse digital signal, ranging from 0 to 1, and it enables flow modulation through adjustments of its amplitude and duty cycle. The valve’s controllability depends on the switching frequency, with lower frequencies offering better control but increasing pressure pulsation [
31].
HFSVs can be used to create a digital hydraulic circuit that replicates the functionality of a conventional four-way three-position (4/3) spool valve.
Figure 1 depicts two digital hydraulic circuits of a 4/3 HFSV, where HFSVs are responsible for establishing fluid pathways P → A, A → T, P → B, and B → T. In particular, in
Figure 1a, the digital hydraulic circuit of the 4/3 HFSV is realized using four two-way two-position (2/2) HFSVs. However, to reduce the number of components, the digital hydraulic circuit of the 4/3 HFSV can be obtained with just two four-way two-position (4/2) HFSVs, as depicted in
Figure 1b.
The HFSVs utilized in the digital hydraulic circuits presented in
Figure 1 are designed to meet specific requirements. These include the need to switch rapidly from fully open to closed positions in less than 5 ms, with minimal pressure losses, and the capacity to provide high flow rates while maintaining a compact design [
14]. To achieve high switching speeds, smart materials like piezoelectric actuators, with their simple design, few moving parts, high reliability, and rapid response times, are well suited for constructing this type of digital hydraulic valve [
32].
Over the years, remarkable advancements have been made in the development of HFSVs driven by piezoelectric actuators. In 1991, Yokota et al. developed a 2/2 HFSV with the use of two piezoelectric actuators, achieving an impressive 0.1 ms switching time and a flow rate of 7.2 L/min at 100 bar [
33,
34]. In 2000, Yamada et al. realized a 2/2 HFSV with a spring mechanism and a piezo stack actuator, obtaining a switching time less than 0.8 ms and a flow rate of 3 L/min at 100 bar [
35]. In 2008, Ouyang et al. utilized three piezo stack actuators in a 2/2 HFSV, resulting in a switching time of less than 1 ms and a flow rate of 10 L/min at 200 bar [
36]. In 2019, Yu et al. realized a 2/2 HFSV using a piezo stack actuator with a diamond mechanism amplification, reaching a switching time less than 1 ms and a flow rate of 17.4 L/min at 150 bar [
37].
Despite the fast-switching times, all the “piezo 2/2 HFSVs” discussed earlier cannot be employed in the digital hydraulic circuit depicted in
Figure 1a, as a replacement for a conventional spool valve, due to their limited flow rate delivery. To address this limitation, the authors of this paper conducted a feasibility study on a novel and innovative 2/2 HFSV architecture [
14]. This valve utilizes a multilayer piezoelectric actuator, known as the ring stack, for its actuation. Through open loop predictions performed within the Simulink environment, it was demonstrated that this valve can be effectively integrated into the 4/3 HFSV digital hydraulic circuit shown in
Figure 1a, serving as a viable alternative to proportional and servovalves in various high-speed control applications.
In this scenario, with the aim of simplifying the digital hydraulic circuit from the 4/3 HFSV configuration shown in
Figure 1a to that presented in
Figure 1b, and with the goal of improving the energy efficiency of hydraulic systems, the purpose of this study is to investigate a novel 4/2 HFSV architecture based on the use of the same ring stack actuator. Specifically, building upon our 2/2 HFSV Simulink model [
14], the paper proposes an enhanced numerical code that allows for the simulation of open loop step tests, assessment of the hysteresis of the piezoelectric actuator, and execution of closed loop step tests, offering a more comprehensive analysis.
The paper starts with a detailed description of the valve architecture, illustrating the flow of the equations that are utilized in the Simulink model to evaluate the valve’s performance. This is followed by the validation of the hysteresis model of the ring stack actuator, where a comparison is made between the simulated and real curve in terms of percentage error, based on data from the manufacturer’s website. Subsequently, the paper presents and discusses the numerical results obtained with both open-loop and closed-loop control systems. The results provide insights into the advantages and disadvantages of the proposed valve architecture, which are further discussed in the conclusions.
3. Numerical Model of the 4/2 HFSV Actuated by a Ring Stack
The evaluation of the suggested valve architecture’s performance, specifically the one illustrated in
Figure 2, is conducted by using well-established and referenced equations integrated within Simulink, leveraging the Simscape Fluids libraries [
43]. This approach ensures the validation of the hydraulic model. Additionally, since this model is an extension of our previously verified code [
14], its validation is assured.
The equations implemented in Simulink are described in the following, referring to the actuation of the ring stack and the resulting opening of the valve, as shown in
Figure 3.
The ring stack necessitates an amplifier, which is responsible for converting a low-input control voltage, characterized by an overall period (τ), a switching frequency (f), an amplitude (
), and a duty cycle (DC), into a high-output voltage (
). The relation between the output and the input voltage is simulated by using a second order transfer function
[
14]:
where s is the complex variable, while
,
and
are the gain, natural frequency and damping ratio of the amplifier, respectively. The current limit of the amplifier,
, is computed as follows [
14]:
where
is the capacitance of the ring-stack.
The consideration of piezoelectric hysteresis involves the implementation of the Bouc–Wen hysteresis model, as described and used in reference [
44]. This model enables the computation of the hysteresis nonlinear term, n:
where
,
and
are parameters to be adjusted in order to adapt the hysteresis model to a specific case. The hysteresis non-linear term, n, is used to correct the blocking force,
, because of hysteresis, as follows [
44]:
where
is a correction factor, to be tuned in order to match the numerical model with the experimental data provided by the manufacturer; whereas
is a conversion factor (from voltage to force).
The blocking force,
, determines the actuation force,
which can be calculated as follows [
14]:
where
and x are the stiffness and the displacement of the actuator (the latter is equal to the poppets’ displacement).
When the valve is actuated, the equilibrium of the forces acting on the poppets can be expressed as:
where:
Fs is the force of the additional spring given by Fs = ks (x + δ0), with ks and δ0 representing the stiffness and the pre-compression of the additional spring;
Fc is the force of the additional spring given by Fc = Cẋ, with C representing the damping factor of the poppets (accounting for fluid viscosity);
Fi is the inertia force given by Fi = mẍ, with m representing the mass of the moving parts.
Fflow represents the flow forces acting on the poppets.
To determine the damping factor of the poppets,
, which accounts for the frictional forces acting on them, the following relationship can be utilized [
14]:
where µ is the dynamic viscosity of the oil,
and
are the poppets‘ diameter and length of the part in contact with the case; c is the radial clearance and ε is the radial eccentricity.
The flow of fluid through the valve ports leads to the generation of steady-state and transient flow forces. Steady-state flow forces, which are hydrodynamic effects in stable flow conditions, can be further categorized as axial and radial flow forces [
45]. In contrast, transient flow forces are instantaneous hydrodynamic phenomena that occur during sudden valve port opening or closing [
46]. This analysis focuses only on steady-state flow forces, which occur as oil flows through the two metering chambers. The evaluation of these forces can be performed using the following equation [
44,
47]:
where the factor 2 considers the two metering chambers being opened simultaneously, ρ is the oil density, and
is the velocity angle with respect to the horizontal direction; the volumetric flow rate,
, and the restriction area,
, through each metering chamber can be calculated by the following equations [
14]:
where
is the discharge coefficient and
is the overall pressure drop across the valve. In the model, Port A and Port B are hydraulically connected, and the pressure drop is neglected. Therefore, the pressure drop in Equation (9) becomes:
When oil flows through the metering chambers, it experiences a pressure drop, which results in power consumption. The ideal power average loss in the 4/2 HFSV,
can be determined as follows [
47]:
where
is the average flow rate provided by the valve.
The range of motion for the poppets is constrained by two stops, defining the upper and lower bounds. Each stop incorporates a combination of a spring and a damper. When the poppets reach their maximum displacement (
) or minimum displacement (
), a force (
) is exerted on the ring stack. The calculation for this force is evaluated as follows [
14]:
To simulate the volume of oil between ports (P) and (A), as well as between ports (B) and (T), a block named “Constant Volume Hydraulic Chamber” is utilized. This block serves the purpose of mimicking a chamber with fixed volume and rigid walls, while also considering the compressibility of the fluid. The following equations are applied [
14]:
where
represents the geometrical volume of the chamber. This value is obtained by multiplying the internal diameter (
) by the overall internal length (
). On the other hand,
represents the volume of oil in the chamber at a given pressure (p), while
represents the volumetric flow rate through the chamber. To calculate the actual bulk modulus (E), the following equation is used [
14]:
Both open and closed-loop control systems can be simulated. In the former control system, users have the flexibility to set the switching frequency (f), the overall period (τ), the duty cycle (DC), the amplitude (
) of the input control voltage, as well as the overall pressure across the valve (∆p). The resulting output variables include the average flow rate (
) and the average power consumption (
). Conversely, in the latter control system, a Proportional-Integral (PI) controller is employed to adjust the duty cycle of the input pulse digital signal, aiming to achieve the desired average flow rate, based on the calculated error term e(t):
where
and
denote the proportional and integral gain, respectively. The controller does not incorporate derivative action due to its susceptibility to noise in the process-variable signal.
The Simulink solver, specifically Ode14x, calculates the states of the dynamic system at consecutive time intervals of 0.1 ms over a defined period.
To recap,
Figure 4 and
Figure 5 display two structured block diagrams that provide a visual representation of how the previously described equations flow in open and closed control systems, respectively. The color of each block clarifies whether it represents the input variables, the input system parameters, or the resulting output variables.
4. Results
The following section presents and discusses the results of the numerical simulations conducted on both metering chambers of the 4/2 HFSV, specifically P → A and B → T. The initial step involved the validation of the hysteresis model using the data provided by Noliac on their website [
39].
Figure 6 visually represents the hysteresis curve, illustrating the relationship between the electric field supplied to the actuator and the resulting strain percentage. More precisely,
Figure 6a,b illustrates the percentage error between the ascending and descending branches obtained by the simulation and provided by the manufacturer, respectively. Meanwhile,
Figure 6c offers a comprehensive comparison of the entire simulated hysteresis curve with the corresponding manufacturer’s data. The manufacturer’s curve pertains specifically to the piezoceramic material NCE51F, which is used in constructing the NAC 2125 HXX ring stack model. It is important to note that the strain percentage indicated on the graph applies exclusively to the active material. In practical multilayer piezoelectric actuators, there are additional inactive layers present on each ceramic element, as well as on the top and bottom of the entire stack. Considering a total stack height of 200 mm, the active material accounts for a length of 156 mm, with each active layer in the stack having a thickness of around 67 µm. In the graph, the hysteresis curve plotted in red with a continuous line represents the manufacturer’s data. To obtain the simulated hysteresis curve (plotted in blue with a dotted line), the mentioned equations in
Section 3 were used with tuned parameters
,
,
and
. A 1 Hz sinusoidal input control voltage with amplitude, ranging from 0 to +5 V, was applied in the simulation. No load was applied, meaning
and
were all set to 0. The simulation utilized the characteristics of the NAC2125 H200 model, where
and
. The amplifier employed in the simulations is characterized by
,
and
. The close agreement between the simulation curve and the manufacturer’s curve, with a percentage error of less than 15% in both the ascending and descending branches, demonstrates the accuracy of the hysteresis model.
Once the hysteresis model was validated, the 4/2 HFSV architecture depicted in
Figure 4 was simulated using the numerical code described in
Section 3.
In the simulation, the oil used was ISO VG 32, maintained at a temperature of 50 °C. The oil properties were characterized by a density
851 kg/m
3 and
0.0187 kg/(ms). The discharge pressure to the tank (
) was assumed to be constant and equal to 1 bar. Considering the dimensions of the ring stack actuator, the two poppets inserted through the hole of the stack were assumed to have a diameter
60 mm and an angle
45°. For the same reason, the length of the part in contact with the case (
) was assumed to be 50 mm, with a clearance (c) of 1 µm. Taking the piezoelectric actuation into an account, a mass
100 g was considered to represent the moving parts. The damping factor of the poppets was calculated using Equation (7): assuming negligible eccentricity (ε), the calculated damping factor is C
= 60 Ns/m. The chamber accounting for fluid compressibility, given the dimensions of the poppets, was assumed to have
60 mm and
50 mm, thus obtaining
2 ×
m
3. Regarding the discharge coefficient, it was assumed to remain constant at
0.7, under the hypothesis of turbulent flow [
1].
To achieve a preload equal to 20% of the maximum blocking force [
25], the additional spring was assumed to have a stiffness of
N/m. It was pre-compressed by
8.90 mm. The maximum displacement, represented by the mechanical stop, was defined as
0.325 mm, which corresponds to the maximum free stroke of the ring stack. For the mechanical stops, the spring stiffness was set to
N/m, while the damping was assigned a value of
3000 Ns/m.
The operating parameters for the ring stack actuator were reported in
Table 1, while the input system parameters, including the hysteresis parameters for the ring stack, can be found in
Table 2. Additionally,
Table 3 shows the input and output variables that will be set and obtained from the simulations for both open and closed-loop control systems.
All the numerical results were obtained by maintaining the period of the input pulse digital signal constant (or input control voltage) constant, specifically set at τ = 5 ms, resulting in a switching frequency equal to f = 200 Hz.
First, the impact of the amplitude of the input control voltage on the performance of the 4/2 HFSV was investigated.
Figure 7 shows open-loop predictions conducted with varying amplitudes of the input pulse digital signal during four different periods: 0 to 2 V, 0 to 3 V, 0 to 4 V, and 0 to 5 V. The analysis took into account an overall pressure drop across the valve of
15 bar and a duty cycle of the input pulse digital signal set at
60%. Specifically,
Figure 7a shows the time history of the quantities provided to the ring stack actuator. These quantities include the amplitude of the input control voltage,
(multiplied by 20 for clarity), the amplified voltage,
the current, i, and the average current,
. Furthermore, the time history of the resulting blocking force achieved,
, is also depicted in the graph.
Figure 7b illustrates the time history of the forces related to the actuation of the ring stack. Specifically, it presents the actuation force developed by the ring stack, denoted as
, along with the resistant forces. These resistant forces included the viscous force,
, the inertia force,
, the force of the additional spring,
, and the flow forces,
.
Figure 7c displays the time history of poppets’ position, x, the obtained instantaneous flow rate,
, the obtained average flow rate,
, and the average ideal power dissipated by the valve,
.
Referring to
Figure 7a, the amplitude of input control voltage,
, is amplified to a higher pulse voltage,
, by the amplifier within approximately 1 ms. This amplified voltage was then corrected by the hysteresis non-linear term,
, and then converted into the blocking force,
, using the conversion factor,
, and the correction factor,
. It is worth noting that a higher amplitude of the input control voltage resulted in a higher blocking force. Specifically, when the amplitude of the input control voltage reached its maximum value of 5 V, the maximum value of the blocking force was obtained. However, due to the hysteresis of the ring stack actuator, the blocking force did not return to zero when the input control voltage was removed. Moreover, the graph revealed that as the amplitude of the input control voltage increased, the current, i, experienced a higher peak value. In particular, during the fourth period, the peak of current reached its maximum value of 43.5 A. However, it is important to note that this peak of current occurred only for a short duration, and the average current,
, remained relatively low, below 6 A.
When examining the predictions of
Figure 7b, it became apparent that both the viscous force,
, and the flow force,
, had negligible effects on the actuation capability of the ring stack actuator. This was because these forces were considerably smaller than the actuation force,
, which was determined by the difference between the blocking force,
, and the ring stack spring force,
. Therefore, the actuation force did not return to zero when the input control voltage was removed. On the other hand, the force of the additional spring,
, and the inertia force,
, played significant roles in the actuation of the ring stack. The force of the additional spring was particularly influential due to the value of the preload,
. On the other hand, the oscillations in the actuation force were caused by the inertia force attributed to the relatively lower damping factor, C, calculated for the poppets. Therefore, it was crucial to ensure that the mass of the moving parts,
, was not excessively large in order to minimize these oscillations and enhance the performance of the 4/2 HFSV.
With regard to the predictions of
Figure 7c, the actuation force,
, allowed the poppets to move and reach the open position in less than 1 ms. Due to the oscillations in the actuation force, the poppets oscillated around the open position, which may not have been equal to the maximum free stroke,
, due to the presence of resistant forces. However, despite the hysteresis of the ring stack actuator, the force stored in the additional spring,
, was substantial enough to ensure that the poppets could close the valve when the input control voltage was removed. The poppets’ position,
, exhibited a similar trend to the obtained instantaneous flow rate,
, indicating a correlation between the two variables. It is worth noting that the amplitude of the input control voltage,
, directly influenced the obtained average flow rate,
. As the amplitude increased, the average flow rate also increased. During the fourth period, when the amplitude of the input control voltage reached its maximum value (i.e.,
5 V), an average flow rate of
34.74 L/min was achieved. Given that the overall pressure drop across the valve remained constant, the ideal average power dissipated by the valve,
, followed a similar trend to the average flow rate. It is important to note that when the input control voltage was equal to its maximum, an ideal average power consumption of only
868.4 W was observed.
The results shown in
Figure 8 provide an evaluation of how the performance of the 4/2 HFSV is affected by the duty cycle of the input control voltage. To conduct these evaluations, open-loop step tests were performed, resembling the tests shown in
Figure 7, but this time changing the duty cycle of the input pulse digital signal. Four different periods, with different values of the duty cycle, were examined, specifically DC = 30%, DC = 40%, DC = 60%, and DC = 80%. The analysis considered an overall pressure drop across the valve of
15 bar and an amplitude of the input control voltage of
5 V. It is evident that increasing the duty cycle, DC, led to a higher average flow rate,
, and, consequently, an increase in the ideal average power dissipated by the valve,
. Specifically, during the fourth period with a duty cycle of 80%, an average flow rate of
46.78 L/min and an ideal average power consumption of
1170 W were achieved.
To resume the impact of the amplitude (
) and duty cycle (DC) of the input control voltage,
Figure 9 illustrates the average flow rate (
) provided by the valve as the amplitude and duty cycle of the input control voltage vary. The analysis considered an overall pressure drop across the valve of
15 bar. The simulations demonstrated that as both the amplitude and duty cycle of the input control voltage increased, the average flow rate also increased. Specifically, when applying the maximum duty cycle and maximum amplitude of the input control voltage to the ring stack actuator, the valve achieved an impressive average flow rate of
60 L/min.
Figure 7,
Figure 8 and
Figure 9 depict open-loop simulations conducted with an overall pressure drop across the valve set at
15 bar. The chosen pressure drop value aims to design a valve that can provide high flow rates while maintaining low pressure drops. Therefore, a pressure drop of 7.5 bar for each metering chamber (P → A and B → T) was considered appropriate for this purpose, leading to a total pressure drop of 15 bar across the valve.
Figure 10 and
Figure 11 evaluate the influence of the inlet pressure (
) on the average flow rate (
) and the ideal average power dissipated by the valve (
). Each figure focuses on a specific quantity, with
Figure 10 presenting the average flow rate and
Figure 11 illustrating the ideal average power dissipated by the valve. The analysis involves varying the duty cycle (
) while keeping the amplitude of the input control voltage constant at
5 V. Different values of
were considered in the investigation, specifically
= 10 bar,
= 15 bar,
= 20 bar,
= 25 bar. It is worth noting that as the overall pressure drop across the valve increased, the average flow rate also increased. For example, at
100% and
25 bar, the average flow rate reached its maximum value of
77 L/min. However, it is important to consider the trade-off between the average flow rate and average power consumption. Since the ideal average power dissipated by the valve (
) was calculated as the product of the average flow rate (
) and the pressure difference (
), the ideal average power consumption became significantly high. For the mentioned case of
100% and
25 bar, the ideal average power dissipation amounted to
3208 W.
For real applications, closed-loop control is essential to ensure proper control. In this scenario, closed-loop control was simulated using a simple PI controller. The controller adjusts the duty cycle of the input control voltage, which has an amplitude of = 5 V, based on Equation (18), to achieve the desired average flow rate (set point). The PI controller parameters, and , were determined using the Ziegler–Nichols method and set to 0.01125 and 3.6, respectively. The back calculation anti-windup method was employed.
In the simulated closed-loop step tests, the set point was adjusted three times, specifically from 0 to 20 L/min (
Figure 12a), from 0 to 30 L/min (
Figure 12b), and from 0 to 40 L/min (
Figure 12c). The overall pressure difference across the valve,
was set to 15 bar for these tests. The parameters specified in
Table 1 and
Table 2 were also used in these simulations.
These graphs provide clear evidence of the effectiveness of the closed-loop control system. It is evident that the system efficiently reached the desired set point by making only three changes in the duty cycle of the input control voltage. Remarkably, this achievement was accomplished in less than 15 ms.
5. Conclusions
This study investigated the potential application of a commercially available ring stack actuator for the actuation of an innovative 4/2 HFSV (High-Frequency Switching Digital Hydraulic Valve). By harnessing the benefits provided by these piezo actuators, such as their rapid response and lightweight characteristics, the demanding requirements of such digital hydraulic valves have been successfully met.
The effectiveness of the designed 4/2 HFSV architecture was assessed by applying well-established equations within a Simulink environment. The hysteresis of the ring stack actuator was precisely simulated through the utilization of the Bouc–Wen model, and its accuracy was verified through a comparison with experimental data, which showed a percentage error of less than 15% in both the ascending and descending branches.
The analysis presented numerical results obtained from an open-loop control system, followed by discussions of the results obtained in closed-loop control. The simulations, along with the analysis of the ring stack actuator’s characteristics, revealed both the advantages and disadvantages of the proposed valve’s architecture.
In terms of positive aspects, the proposed valve design stands out for its simplicity, as the ring stack directly controls the opening and closing of poppets with the application or removal of the input pulse digital signal. The simulations demonstrated that the actuation force provided by the piezoelectric actuator was capable of overcoming the opposing forces and ensuring a rapid response, enabling the valve to reach the open position in less than 1 ms. Additionally, the hysteresis of the ring stack actuator wasn’t a significant problem, as the stored force in the additional spring was ample to ensure the poppets closed the valve when the input pulse digital signal was removed.
In the simulated open-loop tests, it was observed that increasing the amplitudes and duty cycles of the input pulse signal, as well as the pressure drops across the valve, led to higher average flow rates and average power consumption. This finding highlighted the need to find a trade-off between the average flow rate and the average power dissipation. The optimal trade-off was found to be a duty cycle of 100%, an amplitude of 5 V for the input pulse digital signal, and an overall pressure drop of 15 bar across the valve. This resulted in an average flow rate of 60 L/min and an average power dissipation of only 1500 W, meeting the stringent requirements of HFSVs.
The closed-loop step tests were performed to evaluate the effectiveness of the control system. The code was configured with three different set points for the desired average flow rate, specifically 20 L/min, 30 L/min, and 40 L/min. The numerical results demonstrated that the control system successfully achieved the desired average flow rate by adjusting the duty cycle of the input control voltage only three times, all within a duration of less than 15 ms.
In terms of negative aspects, the simulations showed that due to the high switching frequency of the input pulse digital signal and the low value of the poppets’ damping factor (e.g., 60 N/ms), the mass of the moving parts must be sufficiently small (e.g., 100 g) to limit the oscillations in the poppet positions and the instantaneous flow rate. Additionally, the high cost and large size of piezoelectric actuators, along with the need for a high-performance amplifier, pose challenges for the proposed valve architecture. Nevertheless, the potential future mass production of these actuators might present a promising resolution to mitigate their high cost.