Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review
Abstract
:1. Introduction
2. Materials and Methods
2.1. Types of Interventions
2.2. Outcome Measures
2.3. Search Strategy
2.4. Selection Criteria and Data Extraction
2.5. Risk of Bias
2.6. Statistical Analysis
3. Results
3.1. Identified Articles
3.2. Quality Assessment
3.3. Included Studies
4. Discussion
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Smitkarn, P.; Subbalekha, K.; Mattheos, N.; Pimkhaokham, A. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J. Clin. Periodontol. 2019, 46, 949–957. [Google Scholar] [CrossRef]
- Carosi, P.; Ferrigno, N.; Arcuri, C.; Laureti, M. Computer-Aided Surgery and Immediate Loading to Rehabilitate Complete Arch with Four Dental Implants and Fixed Screw-Retained Prosthesis Up to 4 Years in Function: A Retrospective Study. Int. J. Oral Maxillofac. Implants 2021, 36, 1180–1187. [Google Scholar] [CrossRef]
- Carosi, P.; Ferrigno, N.; Renzi, G.D.; Laureti, M. Digital Workflow to Merge an Intraoral Scan and CBCT of Edentulous Maxilla: A Technical Report. J. Prosthodont. Off. J. Am. Coll. Prosthodont. 2020, 29, 2020. [Google Scholar] [CrossRef] [PubMed]
- Di Murro, B.; Canullo, L.; Pompa, G.; Di Murro, C.; Papi, P. Prevalence and treatment of retrograde peri-implantitis: A retrospective cohort study covering a 20-year period. Clin. Oral Investig. 2021, 25, 4553–4561. [Google Scholar] [CrossRef] [PubMed]
- Joda, T.; Ferrari, M.; Gallucci, G.O.; Wittneben, J.G.; Brägger, U. Digital technology in fixed implant prosthodontics. Periodontology 2000 2016, 73, 178–192. [Google Scholar] [CrossRef] [PubMed]
- Pozzi, A.; Arcuri, L.; Carosi, P.; Nardi, A.; Kan, J. Clinical and radiological outcomes of novel digital workflow and dynamic navigation for single-implant immediate loading in aesthetic zone: 1-year prospective case series. Clin. Oral Implants Res. 2021, 32, 1397–1410. [Google Scholar] [CrossRef]
- Pozzi, A.; Hansson, L.; Carosi, P.; Arcuri, L. Dynamic navigation guided surgery and prosthetics for immediate loading of complete-arch restoration. J. Esthet. Restor. Dent. 2021, 33, 224–236. [Google Scholar] [CrossRef]
- Pozzi, A.; Polizzi, G.; Moy, P.K. Guided surgery with tooth-supported templates for single missing teeth: A. critical review. Eur. J. Oral Implants 2016, 9 (Suppl. 1), 135–153. [Google Scholar]
- Tahmaseb, A.; Wu, V.; Wismeijer, D.; Coucke, W.; Evans, C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin. Oral Implants Res. 2018, 29, 416–435. [Google Scholar] [CrossRef] [Green Version]
- Gallardo, Y.N.R.; da Silva-Olivio, I.R.T.; Mukai, E.; Morimoto, S.; Sesma, N.; Cordaro, L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: A systematic review and meta-analysis. Clin. Oral Implants Res. 2016, 28, 602–612. [Google Scholar] [CrossRef]
- Zhou, W.; Liu, Z.; Song, L.; Kuo, C.-L.; Shafer, D.M. Clinical Factors Affecting the Accuracy of Guided Implant Surgery-A Systematic Review and Meta-analysis. J. Evid. Based Dent. Pr. 2017, 18, 28–40. [Google Scholar] [CrossRef] [PubMed]
- D’haese, J.; Ackhurst, J.; Wismeijer, D.; Bruyn, H.D.; Tahmaseb, A. Current state of the art of computer-guided implant surgery. Periodontology 2000 2016, 73, 121–133. [Google Scholar] [CrossRef] [PubMed]
- Tahmaseb, A.; Wismeijer, D.; Coucke, W.; Derksen, W. Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review. Int. J. Oral Maxillofac. Implants 2014, 29, 25–42. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [PubMed]
- Higgins, J.P.T.; Altman, D.G.; Gøtzsche, P.C.; Jüni, P.; Moher, D.; Oxman, A.D.; Savović, J.; Schulz, K.F.; Weeks, L.; Sterne, J.A.C.; et al. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 2011, 343, d5928. [Google Scholar] [CrossRef] [Green Version]
- Stang, A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur. J. Epidemiol. 2010, 25, 603–605. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Amorfini, L.; Migliorati, M.; Drago, S.; Silvestrini-Biavati, A. Immediately Loaded Implants in Rehabilitation of the Maxilla: A Two-Year Randomized Clinical Trial of Guided Surgery versus Standard Procedure. Clin. Implant Dent. Relat. Res. 2017, 19, 280–295. [Google Scholar] [CrossRef]
- Majewski, P. Piezoelectric Surgery in Autogenous Bone Block Grafts. Int. J. Periodontics Restor. Dent. 2014, 34, 355–363. [Google Scholar] [CrossRef] [Green Version]
- Meloni, S.M.; Tallarico, M.; De Riu, G.; Pisano, M.; Deledda, A.; Lolli, F.M.; Massarelli, O.; Tullio, A. Guided implant surgery after free-flap reconstruction: Four-year results from a prospective clinical trial. J. Cranio-Maxillofac. Surg. 2015, 43, 1348–1355. [Google Scholar] [CrossRef]
- Tallarico, M.; Esposito, M.; Xhanari, E.; Caneva, M.; Meloni, S.M. Computer-guided vs freehand placement of immediately loaded dental implants: 5-year postloading results of a randomised controlled trial. Eur. J. Oral Implantol. 2018, 11, 203–213. [Google Scholar]
- Pozzi, A.; Tallarico, M.; Marchetti, M.; Scarfò, B.; Esposito, M. Computer-guided versus free-hand placement of immediately loaded dental implants: 1-year post-loading results of a multicentre randomised controlled trial. Eur. J. Oral Implantol. 2014, 7, 229–242. [Google Scholar]
- Cassetta, M.; Stefanelli, L.V.; Giansanti, M.; Mambro, A.D.; Calasso, S. Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide. Int. J. Oral Maxillofac. Surg. 2011, 40, 1377–1387. [Google Scholar] [CrossRef] [PubMed]
- Cassetta, M.; Giansanti, M.; Mambro, A.D.; Calasso, S.; Barbato, E. Accuracy of two stereolithographic surgical templates: A retrospective study. Clin. Implant Dent. Relat. Res. 2011, 15, 448–459. [Google Scholar] [CrossRef] [PubMed]
- Bernard, L.; Vercruyssen, M.; Duyck, J.; Jacobs, R.; Teughels, W.; Quirynen, M. A randomized controlled clinical trial comparing guided with nonguided implant placement: A 3-year follow-up of implant-centered outcomes. J. Prosthet. Dent. 2019, 121, 904–910. [Google Scholar] [CrossRef]
- Tallarico, M.; Meloni, S.M.; Canullo, L.; Caneva, M.; Polizzi, G. Five-Year Results of a Randomized Controlled Trial Comparing Patients Rehabilitated with Immediately Loaded Maxillary Cross-Arch Fixed Dental Prosthesis Supported by Four or Six Implants Placed Using Guided Surgery. Clin. Implant Dent. Relat. Res. 2015, 18, 965–972. [Google Scholar] [CrossRef]
- Pomares, C.; Puig, C.P. A retrospective study of edentulous patients rehabilitated according to the ‘all-on-four’ or the ‘all-on-six’ immediate function concept using flapless computer-guided implant surgery. Eur. J. Oral Implantol. 2010, 3, 155–163. [Google Scholar]
- Barrio, R.A.L.-D.; De Paula, W.N.; De Bruyn, H.; Marcantonio, E.; Cosyn, J. A prospective study on implants installed with flapless-guided surgery using the all-on-four concept in the mandible. Clin. Oral Implants Res. 2011, 24, 428–433. [Google Scholar] [CrossRef]
- Meloni, S.M.; Riu, G.D.; Pisano, M.G.; Cattina, G.; Tullio, A. Implant treatment software planning and guided flapless surgery with immediate provisional prosthesis delivery in the fully edentulous maxilla. A retrospective analysis of 15 consecutively treated patients. Eur. J. Oral Implantol. 2010, 3, 245–251. [Google Scholar]
- Orentlicher, G.; Horowitz, A.; Goldsmith, D.; Delgado-Ruiz, R.; Abboud, M. Cumulative survival rate of implants placed “fully guided” using CT-guided surgery: A 7-year retrospective study. Compendium Contin. Educ. Dent. 2014, 35, 590–598. [Google Scholar]
- Marra, R.; Acocella, A.; Alessandra, R.; Ganz, S.D.; Blasi, A. Rehabilitation of Full-Mouth Edentulism: Immediate Loading of Implants Inserted With Computer-Guided Flapless Surgery Versus Conventional Dentures: A 5-Year Multicenter Retrospective Analysis and OHIP Questionnaire. Implant Dent. 2017, 26, 54–58. [Google Scholar] [CrossRef]
- Katsoulis, J.; Avrampou, M.; Spycher, C.; Stipic, M.; Enkling, N.; Mericske-Stern, R. Comparison of implant stability by means of resonance frequency analysis for flapless and conventionally inserted implants. Clin. Implant Dent. Relat. Res. 2011, 14, 915–923. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Vasak, C.; Watzak, G.; Gahleitner, A.; Strbac, G.; Schemper, M.; Zechner, W. Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: A prospective radiological study. Clin. Oral Implants Res. 2011, 22, 1157–1163. [Google Scholar] [CrossRef]
- Vercruyssen, M.; Van De Wiele, G.; Teughels, W.; Naert, I.; Jacobs, R.; Quirynen, M. Implant- and patient-centred outcomes of guided surgery, a 1-year follow-up: An RCT comparing guided surgery with conventional implant placement. J. Clin. Periodontol. 2014, 41, 1154–1160. [Google Scholar] [CrossRef] [PubMed]
- Vercruyssen, M.; De Laat, A.; Coucke, W.; Quirynen, M. An RCT comparing patient-centred outcome variables of guided surgery (bone or mucosa supported) with conventional implant placement. J. Clin. Periodontol. 2014, 41, 724–732. [Google Scholar] [CrossRef] [PubMed]
- Beretta, M.; Poli, P.P.; Maiorana, C. Accuracy of computer-aided template-guided oral implant placement: A prospective clinical study. J. Periodontal Implant Sci. 2014, 44, 184–193. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- El Kholy, K.; Janner, S.F.M.; Schimmel, M.; Buser, D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin. Implant Dent. Relat. Res. 2018, 21, 101–107. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Stübinger, S.; Buitrago-Tellez, C.; Cantelmi, G. Deviations between Placed and Planned Implant Positions: An Accuracy Pilot Study of Skeletally Supported Stereolithographic Surgical Templates. Clin. Implant Dent. Relat. Res. 2012, 16, 540–551. [Google Scholar] [CrossRef]
- Arısan, V.; Karabuda, C.Z.; Özdemir, T. Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: Surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin. Oral Implants Res. 2010, 21, 980–988. [Google Scholar] [CrossRef]
- Cassetta, M.; Bellardini, M. How much does experience in guided implant surgery play a role in accuracy? A randomized controlled pilot study. Int. J. Oral Maxillofac. Surg. 2017, 46, 922–930. [Google Scholar] [CrossRef]
- Di Giacomo, G.A.; da Silva, J.V.L.; Da Silva, A.M.; Paschoal, G.H.; Cury, P.R.; Szarf, G. Accuracy and Complications of Computer-Designed Selective Laser Sintering Surgical Guides for Flapless Dental Implant Placement and Immediate Definitive Prosthesis Installation. J. Periodontol. 2012, 83, 410–419. [Google Scholar] [CrossRef] [PubMed]
- Vercruyssen, M.; Cox, C.; Coucke, W.; Naert, I.; Jacobs, R.; Quirynen, M. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. J. Clin. Periodontol. 2014, 41, 717–723. [Google Scholar] [CrossRef]
- Verhamme, L.M.; Meijer, G.J.; Bergé, S.J.; Soehardi, R.A.; Xi, T.; De Haan, A.F.; Schutyser, F.; Maal, T.J. An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Mucosa-Supported Surgical Templates. Clin. Implant Dent. Relat. Res. 2014, 17, 1154–1163. [Google Scholar] [CrossRef] [PubMed]
- Verhamme, L.; Meijer, G.; Soehardi, A.; Bergé, S.; Xi, T.; Maal, T. An accuracy study of computer-planned implant placement in the augmented maxilla using osteosynthesis screws. Int. J. Oral Maxillofac. Surg. 2017, 46, 511–517. [Google Scholar] [CrossRef] [PubMed]
- Verhamme, L.M.; Meijer, G.J.; Boumans, T.; De Haan, A.F.J.; Bergé, S.J.; Maal, T.J.J. A Clinically Relevant Accuracy Study of Computer-Planned Implant Placement in the Edentulous Maxilla Using Mucosa-Supported Surgical Templates. Clin. Implant Dent. Relat. Res. 2015, 17, 343–352. [Google Scholar] [CrossRef] [PubMed]
- Van De Wiele, G.; Teughels, W.; Vercruyssen, M.; Coucke, W.; Temmerman, A.; Quirynen, M. The accuracy of guided surgery via mucosa-supported stereolithographic surgical templates in the hands of surgeons with little experience. Clin. Oral Implants Res. 2014, 26, 1489–1494. [Google Scholar] [CrossRef]
- Pettersson, A.; Komiyama, A.; Hultin, M.; Näsström, K.; Klinge, B. Accuracy of Virtually Planned and Template Guided Implant Surgery on Edentate Patients. Clin. Implant Dent. Relat. Res. 2012, 14, 527–537. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Vieira, D.M.; Sotto-Maior, B.S.; Barros, C.A.V.D.S.; Reis, E.S.; Francischone, C.E. Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches. Int. J. Oral Maxillofac. Implants 2013, 28, 1347–1351. [Google Scholar] [CrossRef] [Green Version]
- Geng, W.; Liu, C.; Su, Y.; Li, J.; Zhou, Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement. Int. J. Clin. Exp. Med. 2015, 8, 8442–8449. [Google Scholar]
- Cassetta, M.; Giansanti, M.; Di Mambro, A.; Stefanelli, L.V. Accuracy of Positioning of Implants Inserted Using a Mucosa-Supported Stereolithographic Surgical Guide in the Edentulous Maxilla and Mandible. Int. J. Oral Maxillofac. Implants 2014, 29, 1071–1078. [Google Scholar] [CrossRef] [Green Version]
- Cassetta, M.; Pompa, G.; Carlo, S.D.; Piccoli, L.; Pacifici, A.; Pacifici, L. The influence of smoking and surgical technique on the accuracy of mucosa-supported stereolithographic surgical guide in complete edentulous upper jaws. Eur. Rev. Med. Pharm. 2012, 16, 1546–1553. [Google Scholar]
- Arısan, V.; Karabuda, Z.C.; Piskin, B.; Özdemir, T. Conventional Multi-Slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for Computer-Aided Implant Placement. Part II: Reliability of Mucosa-Supported Stereolithographic Guides. Clin. Implant Dent. Relat. Res. 2012, 15, 907–917. [Google Scholar] [CrossRef] [PubMed]
- Seo, C.; Juodzbalys, G. Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: A Systematic Review. J. Oral Maxillofac. Res. 2018, 9, e1. [Google Scholar] [CrossRef] [PubMed]
- Gargallo-Albiol, J.; Barootchi, S.; Marqués-Guasch, J.; Wang, H.-L. Fully Guided Versus Half-Guided and Freehand Implant Placement: Systematic Review and Meta-analysis. Int. J. Oral Maxillofac. Implants 2020, 35, 1159–1169. [Google Scholar] [CrossRef] [PubMed]
- Tattan, M.; Chambrone, L.; González-Martín, O.; Avila-Ortiz, G. Static computer-aided, partially guided, and free-handed implant placement: A systematic review and meta-analysis of randomized controlled trials. Clin. Oral Implants Res. 2020, 31, 889–916. [Google Scholar] [CrossRef]
- Naeini, E.N.; Atashkadeh, M.; De Bruyn, H.; D’Haese, J. Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance. Clin. Implant Dent. Relat. Res. 2020, 22, 454–467. [Google Scholar] [CrossRef]
- Arcuri, L.; De Vico, G.; Ottria, L. Smart fusion vs. double scan: A comparison between two data-matching protocols for a computer guided implant planning. Clin. Ter. 2016, 167, 55–62. [Google Scholar] [CrossRef]
Excluded Study | Reason for Exclusion |
---|---|
Amorfini et al., 2016 [17]; Testori et al., 2014 [18]. | The study analyzed partially edentulous patients. |
Meloni et al., 2015 [19]; Tallarico et al., 2018 [20]; Pozzi et al., 2014 [21]; Cassetta et al., 2011 [22]; Cassetta et al., 2011 [23]. | Results or statistical analysis are comprehensive and not divided in partially or fully edentulous patients. |
Bernard et al., 2018 [24]; Tallarico et al., 2015 [25]; Pomares et al., 2010 [26]; Landàzuri-Del Barrio et al., 2011 [27]; Meloni et al., 2010 [28]; Orentlicher et al., 2014 [29]; Marra et al., 2017 [30]; Katsoulis 2011 [31]. | The outcomes are different from those established. |
Vasak et al., 2011 [32]. | The authors do not report the number of implants placed in total and in partial edentulous patients. |
Vercruyssen et al., 2014 [33]; Vercruyssen et al., 2014 [34]. | Patients or data repeated in other included articles with longer follow-up. |
Beretta et al., 2014 [35]. | The sample is too small. |
El Kholy et al., 2018 [36]. | In vitro study. |
Stübinger et al., 2014 [37]. | The study analyzed bone-supported templates. |
Author, Year | Study Design | Study Group | N° of Implants Evaluated | Evaluation Software | Angular Deviation ± SD (°) | Linear Deviation at Shoulder Point ± SD (in mm) | Linear Deviation at Apex Point ± SD |
---|---|---|---|---|---|---|---|
Petterson, 2010 [46] | Prospective | 1 | 139 | NobelGuide Evaluation Software | 2.26 ± 2.53 | 0.80 ± 0.89 | 1.09 ± 1.18 |
Di Giacomo, 2012 [40] | Prospective | 1 | 60 | Rhino 4.0 | 6.53 ± 4.31 | 1.35 ± 0.65 | 1.79 ± 1.01 |
Cassetta, 2012 [50] | Retrospective | Fixed | 66 | Mimics | 4.10 ± 2.43 | 1.66 ± 0.57 | 2.11 ± 2.22 |
Arisan, 2012 [51] | RCT | CT | 50 | Analyze | 3.3 ± 1.08 | 0.75 ± 0.32 | 0.80 ± 0.35 |
Arisan, 2012 [51] | CBCT | 52 | 3.47 ± 1.14 | 0.81 ± 0.32 | 0.87 ± 0.32 | ||
Marinho Vieria, 2013 [47] | Prospective | 1 | 62 | NobelGuide Evaluation Software | 1.89 | 1.80 | 2.21 |
Verhamme, 2014 [42] | Prospective | 1 | 104 | NobelGuide Evaluation Software | 2.81 ± 0.36 | 1.37 ± 0.17 | 1.59 ± 0.18 |
Vercruyssen, 2014 [41] | RCT | MATMU | 55 | Mimics | 2.86 ± 1.16 | 1.23 ± 0.60 | 1.57 ± 0.71 |
Vercruyssen, 2014 [41] | FAMU | 52 | 2.71 ± 1.36 | 1.38 ± 0.64 | 1.60 ± 0.70 | ||
Cassetta, 2014 [49] | Prospective | Fixed | 144 | Mimics | 1.09 ± 2.40 | 1.66 ± 0.58 | 2.09 ± 0.75 |
Van de Wiele, 2014 [45] | Prospective | 1 | 75 | Mimics | 5.02 ± 0.39 | 2.05 ± 0.14 | 1.60 ± 0.14 |
Cassetta, 2017 [39] | RCT | Inexperienced | 33 | GeomagicStudio | 3.21 | 0.60 ± 0.25 | 0.67 ± 0.34 |
Cassetta, 2017 [39] | RCT | Experienced | 37 | GeomagicStudio | 3.07 | 0.74 ± 0.18 | 1.02 ± 0.44 |
Verhamme, 2015 [44] | Prospective | 1 | 150 | NobelGuide Evaluation Software | 3.92 ± 0.81 | 1.96 ± 0.45 | 2.28 ± 0.52 |
Geng, 2015 [48] | Prospective | 1 | 59 | Simplant | 2.71 ± 2.58 | 0.69 ± 0.66 | 0.94 ± 0.75 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Carosi, P.; Lorenzi, C.; Lio, F.; Cardelli, P.; Pinto, A.; Laureti, A.; Pozzi, A. Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review. Materials 2022, 15, 1462. https://doi.org/10.3390/ma15041462
Carosi P, Lorenzi C, Lio F, Cardelli P, Pinto A, Laureti A, Pozzi A. Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review. Materials. 2022; 15(4):1462. https://doi.org/10.3390/ma15041462
Chicago/Turabian StyleCarosi, Paolo, Claudia Lorenzi, Fabrizio Lio, Pierluigi Cardelli, Alessandro Pinto, Andrea Laureti, and Alessandro Pozzi. 2022. "Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review" Materials 15, no. 4: 1462. https://doi.org/10.3390/ma15041462
APA StyleCarosi, P., Lorenzi, C., Lio, F., Cardelli, P., Pinto, A., Laureti, A., & Pozzi, A. (2022). Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review. Materials, 15(4), 1462. https://doi.org/10.3390/ma15041462