1. Introduction
Energy is the essence of today’s world. The entire world is run by the force of energy. The advancement and innovations in the last two decades make life easier as never before. With the rise of technology usage, the need for energy is also rising. As per the report of VGB Powertech [
1], the energy consumption has increased by 66% in the past two decades. The drastic increase in the demand for energy enhanced the consumption of non-renewable fuel, which led to an increase in the pollution as well as cost of fuel. This has caused researchers around the world to concentrate on energy conservation. One of the easiest ways of energy conservation is to increase the efficiencies of various equipment by employing the various techniques (passive and active) to increase the efficacy and reduce the losses.
A heat exchanger (HE) is a device which can exchange the energy between multiple fluids by direct or indirect contact. The fluids at different temperature transfer the energy between them, and hence, the energy exchange takes place. To further increase the heat transfer rate between the fluids, some additional attachment in the form of swirl generators [
2,
3,
4,
5,
6,
7,
8,
9,
10], surface roughness [
11,
12,
13,
14,
15,
16,
17] and other modifications [
18,
19,
20,
21,
22] in the design of the heat exchangers are required. The purpose of using such a modification is to enhance the turbulence in the flow field, which leads to a disturbance in the boundary layer, promotion of secondary flow and better mixing of hot elements with cold field elements [
5,
23,
24,
25,
26]. These modifications also reduce the size of heat exchangers for the same heat exchange capacity. Moreover, the use of materials with higher thermal conductivity, such as steel, copper, brass, aluminum, etc., also promotes the heat transfer rate.
Rashidi et al. [
27] reviewed various articles related to enhanced techniques which employed inserts with nanofluids for heat transfer (HT) enhancement and concluded that combined techniques are more effective over single techniques with a slight increase in the pressure drop (PD). Silva and Salviano [
28] reported on the solar water heater with longitudinal vortex generator to enhance the thermal performance. They found that at a 30° angle of attack, the thermal enhancement factor is highest while the maximum heat transfer was reported with 45°. Gorjaei and Shahidian [
29] experimentally explored the thermal enhancement in a tube fitted with twisted tapes and nanofluid and reported an increase in the heat transfer rate as well as Darcy friction inside the tube. Dadvand et al. [
30] employed a flexible beam kind of vortex generator in the downstream of the fluid domain having a cylindrical obstruction and reported an approximately 18% increase in the Nusselt number (Nu), while a 42% decrease in the Darcy friction was reported. The overall thermal performance was also enhanced. Arulprakasajothi et al. [
31] conducted experiments in the transitional flow regime with conical inserts of different twist ratios fitted inside a cylindrical tube and found that conical strip with a twist ratio of 2 introduced more swirls when compared with other twist ratio inserts. Gnanavel et al. [
32] investigated the thermal performance of a double pipe heat exchanger fitted with rectangular cut twisted tape inserts with different nanofluid flowing through it and reported an enhancement in the thermal performance of the heat exchanger with an increase in the flow velocity. In another numerical investigation by Gnanavel et al. [
33], a similar kind of study was done with circular fin inserts. Keklikcioglu et al. [
34] performed experiments with small length spring tapes coiled conically and welded to a wire fitted inside a cylindrical duct in which an ethylene glycol–water mixture flowed. The study was focused on the turbulent flow regime and results revealed that spring tapes introduced more irreversibility inside the fluid domain as a result enhancement in thermal performance. Klemeš et al. [
35] reviewed the various articles on the heat transfer improvement in heat exchangers and the optimization tools used. They concluded that there is a need to investigate the gap between theoretical approach and practical implementation. Saffarian et al. [
36] conducted a numerical investigation on the different flow paths of a flat plate collector and Al
2O
3 and CuO with water as the working nanofluid. It was found that a wavy and spiral flow path shows maximum enhancement in heat transfer rate while the pressure drop was observed to be maximum with the wavy path. Sheikholeslami et al. [
37] computationally explained the impact of twisted tape within twisted tape for heat transfer augmentation in a cylindrical duct. It is revealed that introduction of secondary tape inside the fluid domain promotes the secondary flow, which result in enhanced entropy in the flow field, and hence, a higher heat transfer rate. Gholami et al. [
38] investigated the influence of adding nanofluid and dimples on the free convective heat transfer in a vertical channel. The results obtained from the investigation revealed augmentation in the thermal performance. Li et al. [
39] reported on the heat transfer enhancement in a microchannel using a shark-skin bionic modified surface and reported an increase in the thermal performance with an increase in the Reynold number. Yu et al. [
40] investigated the influence of triangular baffles on the thermal performance of the air-based PVT collector and reported an increase in both the outlet temperature as well as heat gain at the outlet of the collector. Chen et al. [
41] reported on the factor influencing the heat transfer in ground water heat exchanger and found that an increase in the inlet temperature resulted in a higher heat transfer rate. Giwa et al. [
42] studied the influence of thermo-physical properties, temperature and volume concentration of nanoparticle on the thermal and flow behavior and employed difficult machine learning techniques to predict the thermo-physical properties of nanofluid. Osman et al. [
43] conducted experimental assessment to evaluate the convective heat transfer coefficient in transitional flow regimes. Alumina-water was employed as the working fluid. The results obtained from the investigation shows enhancement in Nu and the heat transfer coefficient. Other, similar investigations include [
44,
45,
46,
47,
48].
A new technique known as machine learning has evolved in recent times which is very helpful in the field of predicting the results with accuracy. It is defined as the method of data analysis that allows the computer to automate the model building. Machine learning is a system that learns from its past data to predict future results and to improve the accuracy using the previous predictions. Machine learning has applications in various industries and is proving its caliber with predicting the results with higher accuracy [
49,
50,
51,
52,
53,
54]. For example, ML is used to analyze a vast volume of data derived from experiments, field measurements and numerical simulations in the field of fluid mechanics [
55,
56]. A data analysis based on machine learning not only increases the throughput and precision of the flow interpretation, but also opens up new possibilities, such as flow property prediction using quality data and past experiences [
57].
The field of thermal science and engineering has also discussed how machine learning is used to promote data processing. Machine learning will act as a useful tool for predicting the results for the complex heat transfer and fluid flow problem in transitional and turbulent flow regimes. Researchers across the globe have found machine learning to be very useful. Lindqvist et al. [
58], Baghban et al. [
59], Kwon et al. [
60] and Krishnayatra et al. [
61] employed a machine learning approach for the development of correlations and predicting the thermal performance for heat exchangers. Baghban et al. [
59] employed the machine learning approach for predicting the thermal performance of a coiled heat exchanger. The multilayer perceptron artificial neural network, adaptive neuro-fuzzy inference system and least squares support vector machine model were employed to predict the Nusselt number; they reported that the least squares support vector machine model predicted the results with the best accuracy. Kwon et al. [
60] employed a random forest algorithm for predicting the heat transfer coefficient by training and testing the machine learning model and reported that the machine learning model predicts the heat transfer coefficient with a high accuracy, i.e., of 96.6%. Ahmadi et al. [
62] employed neural networking for predicting the friction factor in a car radiator while using CuO-water nanofluid as a working agent. Golzar et al. [
63] utilized the machine learning-based technique of artificial neural networking and Monte-Carlo sensitivity analysis for predicting the temperature of wastewater. Koroleva et al. [
64] applied artificial neural networking for optimizing the rib roughness parameters in an internally roughened circular tube. Abdollahi and Shams [
65] engaged the Pareto optimal strategy to optimize the design parameters of a winglet vortex generator to achieve the highest heat transfer enhancement at the lowest pressure drop condition. Sotgiu et al. [
66] employed machine learning for predicting the turbulent heat fluxes in the Reynolds-averaged Navier-Stokes equations and reported that initial results are appreciable, predicting the heat fluxes in a more complex flow. Karkaba et al. [
67] employed large space exploration applications to optimize the design of vortex generators for maximum performance and heat transfer enhancement. Gerdroodbary [
68] formulated a model using neural networking to predict the heat flux for magnetohydrodynamic nanofluid flow. Jovic et al. [
69] explored the potentiality of adaptive neuro-fuzzy methodology in the predicting of heat transfer enhancement for the mini channel heat sink with higher accuracy. Machine learning techniques, such as fuzzy inference system (FIS), support vector machine (SVM) and artificial neural network (ANN), have found application in predicting thermal properties, such as effective thermal conductivity [
70,
71,
72,
73], thermal boundary resistance [
74], recapitulate entropy [
75], specific heat [
76], dynamic viscosity [
77,
78,
79,
80] etc.
A thorough literature review has been done, and this geometry, as shown in
Figure 1, has not been studied previously, neither experimentally nor numerically. A novel experimental investigation of this enhanced geometry can, therefore, be treated as a new substantial contribution in the open literature. This paper also presented a statistical analysis of the heat transfer and fluid flow by developing an artificial neural network (ANN)-based machine learning (ML) model. The model is trained based on the features of experimental data, which provides an estimation of the experimental output based on user-defined input parameters. These models will help the researchers working in heat transfer enhancement-based experiments to understand and predict the output. As a result, the time and cost of the experiments will reduce.
2. Experimental Setup, Procedure and Data Reduction
Figure 2 shows the pictographic representation of the experimental test rig employed for the experimental assessment. All the important parts have been leveled in
Figure 2 for ease of understanding. Air enters the test section with the help of a blower of 7 kW capacity, which then travels through the calming section and enters the test section with uniform distribution. A rotameter with a range of 120 to 540
l/h is employed to measure the mass flow rate of the working fluid. A calibrated U-tube manometer with a measuring range of 0–150 mm of Hg is used to measure the pressure difference in the test section. The measuring range of the major measuring instruments is given in
Table 1. The test section is made of a long circular metallic tube with a diameter of 20 mm and a length of 2 m. The outer surface of the test section is properly insulated to ensure no heat loss to the environment. A total of 36 thermocouples are attached to the surface of the test section at seven equidistant stations to measure the surface temperature of the test section. The system takes approximately 2 h to reach a steady-state condition. The steady state is assumed when fluctuations in the reading were negligible. Further details regarding the experimental setup and produce can be found in the authors’ previous work [
6,
8,
10,
18,
19,
20,
21].
Experimental investigation has been done for various configurations of hybrid tapes, as given in
Table 2.
The Nusselt number (
Nu) can be calculated as follows, where
k denotes the thermal conductivity of air [
61]:
The Darcy friction coefficient,
f, is further evaluated using the following formula [
62,
63]:
For calculating the
ReDh, the authors referred to Bhattacharyya et al. [
21]:
The thermo-hydraulic performance factor (
η) was calculated as per Bhattacharyya et al. [
20], which gave an understanding of the combined performance increases:
3. Results and Discussion
The results obtained for the smooth tube for the Nusselt number and friction factor are validated with the well-established correlations of the Dittus-Boelter correlation [
81], the Meyer et al. [
82] correlation was used for the Nusselt number and Blasius Correlation [
82] for the friction factor.
The Dittus-Boelter correlation [
81] expressed the Nusselt number as follows:
Range: 3000 < Re < 106; 0.7 < Pr < 120
Moreover, Meyer et al. [
82] correlated the Nusselt number as follows:
Range: 2445 < Re < 410,600; 0.5 < Pr < 276
The correlation for the friction factor given by Blasius [
82] is given by:
Range: 4000 < Re < 105
Figure 3 and
Figure 4 show the validation analysis of the present study with previously established and acclaimed correlations for the Nusselt number [
81,
82] and friction factor [
82]. The results obtained for the smooth tube for the Nusselt number and friction factor are in good accordance with previous studies. The Nusselt number deviates only 6% with the Dittus-Boelter correlation and 4% with the Meyer et al. correlation, while the friction factor differs only 4% from the data obtained using the Blasius Correlation.
3.1. Influence on the Nusselt Number
The Nusselt number is a dimensionless parameter which gives the ratio of convection and conductive heat transfer for the fluid. Increase in the value of Nusselt number represents the enhancement in the convective heat transfer.
Figure 5a depicts the relationship of Nusselt number (Nu) and Reynolds number (Re) in a conduit fitted with novel spring corrugated tape for fixed ‘t’ and variable ‘h.’ It is clear from
Figure 5a that an increase in Re results in a higher Nu value. Further enhancement in the average Nusselt number is visible when inserts (spring tape) are employed for the investigation. For a given Reynolds number, the value of the Nusselt number is higher for the channel fitted with inserts than that of a smooth channel, which depicts augmentation of heat transfer in the presence of inserts. The maximum enhancement in the Nusselt number is reported for tape, with t = 1.0 and h = 0.25. For a fixed spring ratio ‘t’, decreasing the value of depth ratio ‘h’ results in a decreased Nusselt number.
Figure 5b depicts that the Nusselt number is the function of the Reynolds number in a conduit fitted with novel spring corrugated tape for a fixed ‘h’ and variable ‘t’. Once again, one can see from
Figure 5b that an increase in the Reynolds number results in the higher Nusselt number value. For a given Reynolds number, the value of the Nusselt number is higher for the channel fitted with inserts than that of the smooth channel which depicts augmentation of heat transfer in the presence of inserts. The maximum enhancement in the Nusselt number is reported for twisted tape with t = 1.0 and h = 0.25. For a fixed h = 0.25, increasing the value of ‘t’ results in a decreased Nusselt number.
Figure 5c depicts the relationship of Nusselt number and Reynolds number in a conduit fitted with novel spring corrugated tape for all possible cases. As expected, the maximum enhancement in Nusselt number is reported for spring tape with t = 1.0 and h = 0.25, while minimum enhancement is noted for spring tape with t = 2.0 and h = 0.
In conclusion, the grooved surface introduced disturbance in the flow field. The depth of the groove brings in irregular disturbance in the flow field. The grooved surface also disrupts the boundary layer, which results in a higher heat transfer rate. The further enhancement in heat transfer is due to the complexity in the flow field due to the presence of spring tape, which makes the flow more complex by generating secondary flow, recirculation and swirls, thereby enhancing the heat transfer rate.
3.2. Influence on the Friction Factor
The thermal performance of the thermal flow system also depends upon the friction factor. Higher friction factor results in a low thermal performance. Hence, one should consider the frictional losses seriously. The presence of inserts (corrugated spring tape) in the flow field helps in the augmentation of heat transfer, but it will also escalate the friction factor. The resulting pressure drop directly led to enhanced power for the same output. The various causes of pressure drops are enhanced contact between fluid and insert, reduction in dynamic pressure, formation of vortices in the flow field, generation of secondary vortex, etc.
Figure 6a–c show that the friction factor (
f) is the function of Re for different combinations of configuration and parameters. As expected in the turbulent flow regime, the friction factor shows a decreasing trend with an increase in the Re.
Figure 6a presented the plot for the friction factor as a function of Re for corrugated spring tape having a fixed spring ratio ‘t’ and variable depth ratio ‘h.’ Increase in the friction factor is noticed when the spring tape is employed. The highest friction factor has been noticed for t = 1.0 and h = 0.25. For a fixed t = 1.0, decreasing the value of h results in decreased friction factor.
Figure 6b shows the plot for friction factor (
f) versus Re for corrugated spring tape having a fixed ‘h’ and variable ‘t’. Increase in friction factor is noticed when spring tape is employed. The highest friction factor has been noticed for t = 1.0 and h = 0.25. For a fixed h = 0.25, increasing the value of ‘t’ results in a decreased friction factor.
Figure 6c depicts the relationship of friction factor and Reynolds number in a conduit fitted with novel spring corrugated tape for all possible cases. The maximum friction factor is reported for spring tape having t = 1.0 and h = 0.25, while the minimum friction factor is noted for spring tape having t = 2.0 and h = 0.
3.3. Influence on the Thermal Performance Factor
Thermo-hydraulic performance factor symbolized by ‘η’ is represented by Equation (4) and is defined as the ratio of the Nusselt number enhancement (
Nu/Nu0) and friction factor enhancement (
f/f0). This factor is the best parameter to evaluate the actual enhancement in the thermal performance of a heat exchanger [
20,
21].
Figure 7a–c shows the various plot for thermo-hydraulic performance as a function of Re for different combinations of parameters.
Figure 7a shows the plot for the thermal performance factor (η) as a function of Re for corrugated spring tape with a fixed spring ratio ‘t’ and variable depth ratio ‘h.’ It is clear from
Figure 7a that ‘η’ is above unity for all the cases, which prove the applicability of the present enhanced geometry. It is also clear from
Figure 7a that an increase in the Reynolds number results in a diminishing thermal performance factor. The highest η is noted for t = 1.0 and h = 0.25 for all Re. A decrease in the value of h results in a decreased value of η.
Figure 7b shows the thermal performance factor (η) as a function of Re for corrugated spring tape having fixed ‘h’ and variable ‘t.’ The highest η is noted for t = 1.0 and h = 0.25 for all Re. Increase in the value of ‘t’ result in decreased value of η.
Figure 7c depicts the relationship of η and Reynolds number in a conduit fitted with novel spring corrugated tape for all possible cases. The highest η is noted for t = 1.0 and h = 0.25 for all Re, while the smallest η is noted for spring tape with t = 2.0 and h = 0. The hydro-thermal characteristics depend on fluid properties, flow conditions as well as geometric parameters of the fin geometry.
It is very important to compare the present geometry with the previously published geometry performance. Thus, the thermohydraulic performance of the present configurations is compared with previously studied geometries [
83,
84,
85,
86,
87] and plotted in the
Figure 8. By looking into
Figure 8 one can easily understand that the present geometry offered superiority over other studied geometries.