Next Article in Journal
Two-Level Full Factorial Design Approach for the Analysis of Multi-Lane Highway Section under Saturated and Unsaturated Traffic Flow Conditions
Next Article in Special Issue
New Evacuated Tube Solar Collector with Parabolic Trough Collector and Helical Coil Heat Exchanger for Usage in Domestic Water Heating
Previous Article in Journal
Non-Aqueous Solvent Mixtures for CO2 Capture: Choline Hydroxide-Based Deep Eutectic Solvents Absorbent Performance at Various Temperatures and Pressures
Previous Article in Special Issue
Design of a Ventilated Façade Integrating a Luminescent Solar Concentrator Photovoltaic Panel
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Optimal Comfortable Load Schedule for Home Energy Management Including Photovoltaic and Battery Systems

1
Centre for Advances in Reliability and Safety, Hong Kong, China
2
Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Hong Kong, China
3
Electrical Power and Machines Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
4
Faculty of Engineering and Technology, Future University in Egypt, Cairo 11835, Egypt
5
Electrical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
*
Author to whom correspondence should be addressed.
Sustainability 2023, 15(12), 9193; https://doi.org/10.3390/su15129193
Submission received: 30 April 2023 / Revised: 29 May 2023 / Accepted: 1 June 2023 / Published: 7 June 2023
(This article belongs to the Special Issue Applications of Renewable Energy Technologies on Buildings)

Abstract

:
Although the main concern of consumers is to reduce the cost of energy consumption, zero-energy buildings are the main concern of governments, which reduce the carbon footprint of the residential sector. Therefore, homeowners are motivated to install distributed renewable energy resources such as solar energy, which includes photovoltaics (PVs), solar concentrators, and energy storage systems (ESSs); these installations are intended to maintain the homeowners’ energy consumption, and the excess energy can be sold to the grid. In light of the comfort consumption suggestions made by users, this paper presents an optimal home energy management (HEM) for zero-energy buildings and low energy consumption. Firstly, this paper proposes a new optimization algorithm called random integer search optimization (RISO). Afterwards, we propose a new objective function to enable zero energy consumption from the grid and lower costs. Therefore, in this study, the primary energy resources for homes are PVs and ESSs, while the grid is on standby during the intermittency of the primary resources. Then, the HEM applies the RISO algorithm for an optimal day-ahead load schedule based on the day-ahead weather forecast and consumers’ comfort time range schedule. The proposed HEM is investigated using a schedule of habits for residential customers living in Hong Kong, where the government subsidizes the excess clean energy from homes to the grid. Three scenarios were studied and compared in this work to verify the effectiveness of the proposed HEM. The results revealed that the load schedule within the comfort times decreased the cost of energy consumption by 25% of the cost without affecting the users’ comfort.

1. Introduction

The cost of energy consumption by residential consumers has increased as a result of the global pandemic and war crisis [1]; according to the International Energy Agency (IEA), in 2021, the worldwide residential energy consumption accounted for 30% of the total energy consumption [2]. Therefore, residential buildings contribute directly or indirectly to around 27% of global greenhouse gas emissions. Thus, according to the Paris Climate Agreement, implementing zero-energy designs in residential buildings can play a crucial role in mitigating climate change, which encourages countries to increase the use of clean energy sources to lower carbon dioxide emissions [3]. As a result, many homeowners look for the available forms of renewable energy, such as solar energy, wind energy, etc., to lessen their carbon footprint and cut costs [4]. To hasten the transition to a cleaner energy future, some governments are also providing tax credits and other financial incentives for the use of renewable energy sources according to the government’s policy [5]; for instance, the Hong Kong government encourages the installation of distributed renewable energy (DRE) sources by offering feed-in tariff subsidies to locals who do so [6]. These actions can also inspire and encourage other sectors to adopt sustainable practices.
Home energy management (HEM) is used to lower the cost of energy usage and the carbon footprint of end users [7]. There are two basic approaches to accomplish these goals: managing the demand response (DR) and providing electricity to houses via renewable energy resources and energy storage systems (ESSs) [8,9]. The DR program is effective during the time of use (TOU) pricing or incentives that are provided by the utility to encourage users to arrange their usage [10]. Furthermore, the DR must schedule the load with the uncertainty and intermittency of DRE, and DREs and ESSs should primarily confront the home demand. Then, the excess energy may be delivered to the utility, which helps with low carbon emissions [11]. DR programs also help lower peak demand, which minimizes the need for new power plants and transmission lines, leading to cost savings for utilities and customers. HEM is made up of smart meters, routers, and communication systems (e.g., Internet of Things (IoT), wireless networks, and cellular networks) that allow for the monitoring and control of various home appliances and systems (e.g., lighting, heating, cooling, and security systems) via a central hub or mobile device. This technology improves the home’s energy efficiency, convenience, and security [12].
In a recent literature review, researchers concentrated on DR management studies that stated that the load could be divided into critical, curtailed, and deferrable loads [13]. Additionally, it was assumed in these studies that the utility would reimburse customers for their rescheduled or interrupted loads. Customers will therefore forego their comfort for lower energy consumption costs. On the other hand, some researchers thought that installing PVs and ESSs was part of DR management [14]. The ambiguity of load demand and DRE generation is currently investigated for home energy management; day-ahead DR management, which uses load profiles, weather forecasts, and real-time utility pricing, can resolve this issue [15]. For day-ahead forecasting, many statistical and machine learning techniques are used. Energy providers can gain essential insights from the accuracy of day-ahead forecasting, which will help them streamline their processes, cut costs, and maintain customer satisfaction [16]. Long-term forecasting using these techniques can help with strategic planning and decision making. This will aid in determining the trade-off between cost savings and consumer comfort. Optimization algorithms are used in home energy management to reduce the cost of energy consumption while keeping the end users’ comfort in mind [17]. These algorithms can make decisions about when and how to use energy in the home based on factors such as weather, energy prices, and user preferences.
In the literature, due to the total increment result of the applied optimization algorithms, such as mathematical, metaheuristic, and machine learning algorithms, researchers have applied these algorithms to the energy management systems. Mathematical algorithms are based on mathematical models and equations, whereas metaheuristic algorithms are founded on stochastic processes that are motivated by natural phenomena, such as evolution and swarm intelligence. As opposed to traditional approaches, machine learning algorithms rely on data-driven approaches; linear programming (LP) [18], quadratic programming (QP) [19], convex programming (CP) [20], dynamic programming (DP) [21], mixed integer linear programming (MILP) [22], and mixed integer nonlinear programming (MINLP [23]) are some of the mathematical algorithms. Although these algorithms are frequently used in HEM, they do not always result in the global optimum solution, and some of them are costly to compute and challenging to solve without assumptions. These days, metaheuristic algorithms [24], which include genetic algorithms (GAs) [25], particle swarm optimization (PSO) [26], differential evolution (DE) [27], the harmony search algorithm (HSA) [28], game theory (BFA), ant colony optimization (ACO) [29], binary grey wolf optimizer (BGWO) [30], and binary backtracking search algorithm (BBSA) [31], are stochastic optimization techniques that can be used to solve complex optimization problems such as HEM. While neural networks (NNs) [32], decision trees, k-nearest neighbor (KNN) [33], reinforcement learning [34], support vector machines (SVMs [35]), and long short-term memory recurrent neural networks (LSTMs [36]) are examples of machine learning algorithms that use data-driven strategies to optimize a system’s performance to create the best load schedule possible for the day-ahead forecasted weather and loads.
Unfortunately, most countries’ electricity suppliers do not pay for load shifting or curtailment; thus, customers need to reduce costs by scheduling their load profile without sacrificing comfort. This can be accomplished by utilizing DRE and smart home technologies that allow customers to control their energy consumption remotely. Moreover, implementing energy-efficient appliances and practices can help reduce costs while maintaining comfort. This paper proposes a new optimization algorithm, a random integer search optimizer (RISO). Moreover, this work offers a new objective function that represents the cost of energy consumption by individual homes. The RISO algorithm is applied to minimize the objective function and to schedule the home appliances within the comfort time window of end users.

2. Home Energy Management System

2.1. System Description

For zero-energy homes in Hong Kong, the government encourages individuals to install distributed PV and ESS systems to supply clean energy to their homes, and the excess energy can be injected into the grid. The Hong Kong government initiated a feed-in tariff scheme to help individuals recover the capital cost of installing renewable energy resources within 10 years of the project. However, individuals still need efficient energy management to optimize household appliance schedules and reduce energy consumption costs. In this study, the structure of HEM is shown in Figure 1. This HEM includes clean energy generation (PVs and ESSs); household appliances, including electric vehicles (EVs), smart meters for measuring the bidirectional energy to or from the grid, communication systems that transfer the decision signals to sockets of appliances or transfer the measured data, and energy hubs that manage the energy flow inside the home and between the home and grid; and software that optimize the schedule of household appliances. The PVs, ESSs, and EVs are connected to the DC distribution system, where bidirectional DC/DC converters are used; the household appliances are connected to the AC distribution system (blue lines), where the PVs and ESSs are connected to them via a bidirectional DC/AC inverter.

2.2. Mathematical Energy Modeling

The decision-making of HEM relies on the day-ahead forecasted energy from PVs and ESSs and the scheduled household appliances. Therefore, the mathematical modeling of the HEM components helps us to study the feasibility of the optimal HEM before deploying it in a real home. Using mathematical modeling, researchers can simulate different scenarios and evaluate the performance of the HEM system under various conditions. This can help to identify potential issues and optimize the system design before it is implemented in a real-world setting.

2.2.1. PV Energy Modeling

As discussed above, the PV system is the main source of home electricity for zero-energy buildings. The output power of the PVs (PPV) varies with the variations in the irradiation (G) and ambient temperature (T), as in Equation (1) [37].
P P V ( t ) = P P V r a t e d η i n v ( 1 + α P ( T ( t ) T 0 ) ) G ( t ) G 0
where αP is the temperature coefficient of the power of PV cells, G0 and T0 are the irradiation and temperature under standard test conditions (STCs) (G0 = 1000 W/m2 and T0 = 25 °C), PPVrated represents the rated installed capacity of PVs at the STC, and ηinv is the efficiency of a DC/AC inverter.

2.2.2. Battery Energy Modeling

The energy flow to or from the batteries depends on the state of charge (SOC) and the maximum rate of charging or discharging power (PBmax). The stored battery energy (εB(t + 1)) increases or decreases with each time step (Δt) during charging or discharging states, as in Equation (2). Therefore, it is essential to monitor the SOC and P B c h to ensure efficient energy management and prevent damage to the batteries.
ε B ( t + 1 ) = ε B ( t ) + Δ t η B 100 P B c h 100 η B P B d c h
P B c h , d c h ( t ) P B max c h , d c h
S O C B ( t + 1 ) = ε B ( t + 1 ) E B S O C B min S O C B ( t + 1 ) S O C B max
where ηB is the total efficiency of DC/DC and DC/AC converters and εB is the total energy storage of the battery.

2.2.3. EV Energy Modeling

An EV is modeled as a battery model, but it will function as a household appliance. Therefore, the charging mode for EVs is considered in this study as follows.
ε E V c h ( t + 1 ) = ε E V c h ( t ) + η E V 100 P E V c h Δ t
P E V c h , d c h ( t ) P E V max c h , d c h
S O C E V ( t + 1 ) = ε E V ( t + 1 ) E E V S O C E V min ε E V ( t + 1 ) S O C E V max

2.2.4. Demand Response Modeling

The main aim of this study is to help residential consumers reduce their carbon footprint by installing clean energy resources and, at the same time, schedule their energy consumption. The load demand is the required power by the household appliances (Phl), including for the EV (PEV), as in Equation (8). This demand will be primarily supplied by the installed renewable energy resources. Therefore, the load demand of the home (PL) is fed by the PV power (PPV) and discharging battery power ( P B d c h ). If there is excess PV power, it will first be used to charge the battery ( P B c h ) until it reaches SOCBmax; the excess power can be sold to the grid after ( P g s ). However, if the demand power (PL) is higher than the PV and ESS power, the shortage power will be bought from the grid ( P g b ), as in Equation (9).
P L ( t ) = P h l ( t ) + P E V ( t )
P L ( t ) = P P V ( t ) P B c h ( t ) ,                 P L < P P V & S O C B < S O C max P P V ( t ) P g s ( t ) ,                 P L < P P V & S O C B = S O C max P P V ( t ) ,                               P L = P P V P P V ( t ) + P B d c h ( t ) ,              P L > P P V & S O C B > S O C min & P B d c h P B max d c h P P V ( t ) + P g b ( t ) + P B max d c h ( t ) ,           P L > P P V & S O C B > S O C min &   P B d c h > P B max d c h P P V ( t ) + P g b ( t ) ,                 P L > P P V & S O C B = S O C min

3. Optimization Methodology

The total demand power of homes (PL(t)) varies with the running time of appliances. Therefore, the running time is the optimization variable of this study, which is an integer value as it is usually coded as an index number for power flow (P(t)). Therefore, this paper proposes stochastic algorithms based on random integer numbers, which have been called the random integer search optimization (RISO) algorithm.

3.1. RISO Algorithm

Commonly, stochastic optimization utilizes a real random number between zero and one; however, the index numbers of matrices in the coding programs are integer numbers. Therefore, applying the famous optimization algorithms requires modifying them to fit the integer variables [38], which affects their accuracy. In this work, we present a straightforward optimization algorithm based on generating random integer numbers called the random integer search optimization (RISO) algorithm. Firstly, this algorithm randomly generates a vector of initial population agents (X), as in Equation (10). After that, the cost function is computed for all population agents, and the agent with the lowest cost is selected to be the best agent (X*), as in Equation (11). Furthermore, a random selection for a random search agent (Xr) will be performed as in Equation (12). Then, the search agents will be updated as in Equation (13). The boundary of the updated agent should be checked to be within the lower and upper boundaries, as in Equation (15). The exploration of the proposed algorithm is achieved by using the random selection of the search agent (Xr); however, the exploitation is achieved by using the variable A. The pseudocode of the proposed RISO algorithm is shown in Algorithm 1.
X = L B + N ( U B L B )
f * ( X * ) = min [ f ( X 1 ) , f ( X 2 ) , f ( X n ) ]
X r = R a n d o m [ X 1 , X 2 , X n ]
X = X * + A X * X r
A = r o u n d ( 2 × r × a a ) a = 2 2 × i t r M a x _ i t r
X [ L B , U B ]
where LB and UB are the vectors of the lower and upper bounds of the optimization variables, N is the random integer vector, r is a real random number ( [ 0,1 ] ), itr is the current iteration, and Max_itr is the total number of iterations.
Algorithm 1 RISO algorithm.
Initialize the search agents X using Equation (10)
find the minimum cost function f*(X*)
While Itr less than Max_iter
          Use Equation (12) to find a random search agent Xr
          Do for all search agents 
                r = random number between [0, 1]
                Use Equation (14) to find the value of a & A
                Update the search agents X using Equation (13)
                Check if the new search agents are within the boundaries as in Equation (15)
                find the cost function for all search agents f(X) using Equation (16)
           End Do
        if f*(X*) > f(X), Update f*(X*) = f(X)
       Itr = Itr + 1
End While
Output f*(X*) and X*

3.2. Objective Function

This study aims to reduce purchasing power from the grid to achieve zero-energy buildings. Furthermore, selling the excess power to the grid can reimburse the capital cost of installing renewable energy resources. Therefore, the minimum bought power from the grid means the minimum cost function, so it is a proportional relationship. On the other hand, the cost function will decrease with the increase in surplus generated power to the grid, so the cost function is inversely related to the sold power to the grid, as in Equation (16).
f = min C T o t a l = min ( t = 1 T ( c b P g b ( t ) Δ t ) t = 1 P g s 0 T ( c s P g s ( t ) Δ t ) )
where CTotal is the total cost and Δt is the step time (h); cb, and cs are the cost of bought and sold power ($/kWh).

3.3. Optimization Flowchart

In this section, Figure 2 displays the optimization flowchart. The demand power (PD) from the grid should be zero wherever the generated PV power is enough to feed the load power (PL). However, the surplus power can be first used to charge the battery system if the battery system’s SOC is less than its maximum value, or it can be sold to the grid (Pg = PD) if the SOC is at its maximum value. Otherwise, if the PV power is insufficient, the system will draw power from the batteries to make up the difference. However, if the power from the PV and batteries is insufficient to feed the demand, the power shortage will be purchased from the grid. Using the RISO algorithm to determine the day-ahead schedule of household appliances based on the day-ahead weather forecast energy demand can help reduce energy costs. Within the predetermined time window, the RISO will determine the best time to turn on the appliances for homeowners. The total cost for the scheduled home appliances is determined in (16). The optimization process will continue up until the maximum number of iterations. The best schedule for the load profile is the final result of this flowchart.

4. Results and Discussion

4.1. Household Appliances

Figure 3 shows some of the common types of household appliances and the preferred time range for them to be used in urban houses in Hong Kong. The prescribed comfort time range is based on people’s common habits and needs to use these appliances. For example, the starting point (tstart) of the range hood appliance is at 5:00 and the end time (tend) is at 17:00, while the duration time of operation is 30 min. The electric vehicle is considered as a household appliance, where it is expected to receive energy in the time range of 00:00 to 9:00 with a duration of 2 h. The hourly load profile for a residential consumer is randomly generated without optimization, as shown in Figure 4. It is clear that the EV charging time interval is 3:30 to 5:30 with a duration time of 2 h. Moreover, the total energy consumption at the end of the day is approximately 29 kWh. For the optimal load profile, the proposed RISO algorithm can be applied to select the best starting time (t*start) in the time range [tstart, tend − Δτ]. Therefore, the proposed method is generalized and flexible enough to be applied to select the optimal operating periods within any comfort time range, which can be suggested by every homeowner.

4.2. Weather Conditions Data

Section 2 describes that the PV power generation varies with the solar irradiation and ambient temperature variations. Therefore, in this study, we employed real hourly data of solar irradiation and temperature in Hong Kong on 1 January 2021, as shown in Figure 5. We assumed that these data are the day-ahead forecasted weather conditions in the winter to test the effectiveness of the proposed HEM. The peak solar radiation is almost 750 W/m2, which occurred at 12:00.

4.3. Case Study

Three scenarios were investigated and compared in this work. The primary source in all scenarios is the PV system, and this work aims to reduce the purchased grid power while simultaneously reducing the cost of energy consumption by using an optimal rescheduling of the load profile. Therefore, we studied three scenarios of home energy management to show the benefits of optimal load rescheduling. Table 1 shows the proposed three scenarios of energy resources with or without an optimal schedule.

4.3.1. Scenario 1

In this scenario, a residential house’s energy sources are presumed to be hybrid photovoltaics (PVs) and the grid, with the load profile being depicted in Figure 4. The load profile includes the charging of an electric vehicle (EV) at a rate of 6 kW for two hours between 3:30 and 5:30 a.m., with the initial state of charge (SOC) being equal to 20% of the total battery capacity (12 kWh). The other household appliances are used according to the house occupation on the weekdays, where the load demand peaks in the morning (7:30 to 9:00) and evening (16:00 to 17:00 and 20:00 to 22:00). The daily energy use is approximately 29 kWh. The capacity of the PV system is 6 kW, which generates electrical power based on the incident solar irradiance and ambient temperature, with the peak power generation occurring during the noon hours. Figure 5 depicts Hong Kong’s sun irradiation and temperature data for January. PV energy is used to meet load demand first, and then the surplus energy is supplied into the grid. However, if the PV power generated is less than the load requirement, the grid will satisfy the load demand, as illustrated in Figure 6. Table 2 summarizes the total energy that is provided to and from the grid. In Hong Kong, the feed-in tariff for power delivered to the grid is 5 HKD/kWh, while the rate for energy acquired from the grid begins at 0.674 HKD/kWh. While the amount of purchased and sold energy is nearly the same, the cost of sold energy is greater to encourage the customers to install solar panels on their homes.

4.3.2. Scenario 2

In this scenario, the battery energy storage system (BESS) is used to reduce the carbon footprint. The BESS’s total capacity is assumed to be 14 kWh, with an initial SOC of 80% of the total capacity. The PV power first meets the load demand, and the surplus power is used to charge the BESS. Any excess PV power will be fed back into the grid if the BESS is fully charged. If the PV power is less than the load demand, the BESS will discharge and meet it. If the load demand exceeds the BESS’s maximum discharge power, the grid supplies extra power. Furthermore, if the SOC of the BESS is 20% of the total capacity, the BESS will stop discharging, and the load demand will be met solely by the grid, as shown in Figure 7. By comparing Table 2 and Table 3, it is obvious that the total energy purchased from the grid in scenario 2 is reduced from 23 kWh to 6.6 kWh. Therefore, in addition to the cost savings, the homeowner reduced around 75% of their carbon footprint, which helps them to achieve the government policy to reduce greenhouse emissions.

4.3.3. Scenario 3

The carbon footprint is further minimized in this case by using load demand management. Customers can change the operating time of their household appliances within their frequent interval operating period. The RISO algorithm redistributes the appliances’ consumption in their frequent interval operating time. The RISO is used to reduce the grid-purchased electricity while increasing the clean energy feed-in to the grid. The objective function is the cost of purchased power divided by the cost of sold power. Figure 8 illustrates the cost savings that are associated with the RISO algorithm. Figure 9 illustrates the shifting load demand and power supplied by the PVs, BESS, and grid. The amount and cost of grid-purchased energy and grid-sold energy are given in Table 4. By comparing Table 3 and Table 4, the amount of grid energy purchased is lowered, resulting in a cost reduction of 25% from 5.37 to 4.01 HKD/day. On the other hand, the amount of clean energy that is sold to the grid is increased from 11.8 to 13.59 kWh, which results in an increase of nearly 9 HKD/day in revenue.

5. Conclusions

This paper introduced a novel optimization algorithm, the RISO algorithm, for a comfortable home energy schedule. Consumers will save money and lessen their carbon footprint without sacrificing comfort thanks to this comfort load schedule, even though the utility will not pay for it. By planning the load demand within the user-friendly usage window, the proposed RISO algorithm helps lower the cost of electricity from the grid. The PV and battery systems are the study’s main energy sources. Grid power is regarded as standby power for residences. The Hong Kong government also encourages homeowners to contribute to lowering their carbon footprints by feeding extra PV power into the grid. Three scenarios, which were enacted with and without an optimal load schedule, were researched to ascertain the efficacy of the proposed HEM system. The obtained simulation results showed that, without compromising user comfort, the optimal load schedule reduced the cost of energy consumption by almost 25%. Residential users can therefore help reduce the grid’s carbon footprint by adding clean power to it or through the construction of zero-energy buildings by adding more batteries to store the extra power. In a future work, we will study the capital cost to implement the proposed method in a real house.

Author Contributions

Conceptualization, M.Q. and K.H.L.; methodology, M.Q. and K.H.L.; software, M.Q.; validation, M.Q., H.M.H. and S.A.; formal analysis, M.Q.; investigation, H.M.H. and S.A.; resources, H.M.H. and S.A.; data curation, K.H.L.; writing—original draft preparation, M.Q.; writing—review and editing, H.M.H. and S.A.; visualization, S.A.; supervision, K.H.L. and H.M.H.; funding acquisition, S.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by King Saud University, Riyadh, Saudi Arabia, under number RSP2023R307.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

This research was funded by the Researchers Supporting Project number RSP2023R307, King Saud University, Riyadh, Saudi Arabia.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

εBEnergy of battery (kWh)
GSolar irradiation (W/m2)
SOCState of charge
ηEfficiency
αpTemperature coefficient of power
EBTotal energy of battery (kWh)
PLLoad power (kW)
PPVOutput power of PV module (W)
PBCharging or discharging power of battery (kW)
PgGrid power (kW)
PDDifference power (kW)
TTemperature (K)
PCHCharging power (kW)
PDSCHDischarging power (kW)
PdcmaxMaximum discharging power rate (kW)
PcmaxMaximum charging power rate (kW)

Abbreviations

RISORandom integer search optimization
PVPhotovoltaic
HEMHome energy management
STCStandard test condition
ESSEnergy storage system

References

  1. Guan, Y.; Yan, J.; Shan, Y.; Zhou, Y.; Hang, Y.; Li, R.; Liu, Y.; Liu, B.; Nie, Q.; Bruckner, B.; et al. Burden of the global energy price crisis on households. Nat. Energy 2023, 8, 304–316. [Google Scholar] [CrossRef]
  2. Buildings. 2022. Available online: https://www.iea.org/reports/buildings (accessed on 1 April 2023).
  3. Luo, Y.; Zhang, L.; Liu, Z.; Yu, J.; Xu, X.; Su, X. Towards net zero energy building: The application potential and adaptability of photovoltaic-thermoelectric-battery wall system. Appl. Energy 2020, 258, 114066. [Google Scholar] [CrossRef]
  4. Fouad, M.M.; Iskander, J.; Shihata, L.A. Energy, carbon and cost analysis for an innovative zero energy community design. Sol. Energy 2020, 206, 245–255. [Google Scholar] [CrossRef]
  5. Li, X.; Lin, A.; Young, C.-H.; Dai, Y.; Wang, C.-H. Energetic and economic evaluation of hybrid solar energy systems in a residential net-zero energy building. Appl. Energy 2019, 254, 113709. [Google Scholar] [CrossRef]
  6. Feed-In Tariff. Available online: https://www.gov.hk/en/residents/environment/sustainable/renewable/feedintariff.htm (accessed on 1 April 2023).
  7. Liu, Y.; Ma, J.; Xing, X.; Liu, X.; Wang, W. A home energy management system incorporating data-driven uncertainty-aware user preference. Appl. Energy 2022, 326, 119911. [Google Scholar] [CrossRef]
  8. Xu, D.; Zhong, F.; Bai, Z.; Wu, Z.; Yang, X.; Gao, M. Real-time multi-energy demand response for high-renewable buildings. Energy Build. 2023, 281, 112764. [Google Scholar] [CrossRef]
  9. Qais, M.H.; Hasanien, H.M.; Alghuwainem, S.; Elgendy, M.A. Output Power Smoothing of Grid-Tied PMSG-Based Variable Speed Wind Turbine Using Optimal Controlled SMES. In Proceedings of the 2019 54th International Universities Power Engineering Conference, UPEC 2019, Bucharest, Romania, 3–6 September 2019; pp. 1–6. [Google Scholar] [CrossRef] [Green Version]
  10. Zheng, S.; Qi, Q.; Sun, Y.; Ai, X. Integrated demand response considering substitute effect and time-varying response characteristics under incomplete information. Appl. Energy 2023, 333, 120594. [Google Scholar] [CrossRef]
  11. Haley, B.; Gaede, J.; Winfield, M.; Love, P. From utility demand side management to low-carbon transitions: Opportunities and challenges for energy efficiency governance in a new era. Energy Res. Soc. Sci. 2020, 59, 101312. [Google Scholar] [CrossRef]
  12. Silva, J.A.A.; López, J.C.; Guzman, C.P.; Arias, N.B.; Rider, M.J.; da Silva, L.C.P. An IoT-based energy management system for AC microgrids with grid and security constraints. Appl. Energy 2023, 337, 120904. [Google Scholar] [CrossRef]
  13. Javed, M.S.; Jurasz, J.; McPherson, M.; Dai, Y.; Ma, T. Quantitative evaluation of renewable-energy-based remote microgrids: Curtailment, load shifting, and reliability. Renew. Sustain. Energy Rev. 2022, 164, 112516. [Google Scholar] [CrossRef]
  14. Korjani, S.; Casu, F.; Damiano, A.; Pilloni, V.; Serpi, A. An online energy management tool for sizing integrated PV-BESS systems for residential prosumers. Appl. Energy 2022, 313, 118765. [Google Scholar] [CrossRef]
  15. Zhu, X.; Sun, Y.; Yang, J.; Dou, Z.; Li, G.; Xu, C.; Wen, Y. Day-ahead energy pricing and management method for regional integrated energy systems considering multi-energy demand responses. Energy 2022, 251, 123914. [Google Scholar] [CrossRef]
  16. Jani, A.; Karimi, H.; Jadid, S. Two-layer stochastic day-ahead and real-time energy management of networked microgrids considering integration of renewable energy resources. Appl. Energy 2022, 323, 119630. [Google Scholar] [CrossRef]
  17. Golmohamadi, H.; Keypour, R.; Bak-Jensen, B.; Pillai, J.R. Optimization of household energy consumption towards day-ahead retail electricity price in home energy management systems. Sustain. Cities Soc. 2019, 47, 101468. [Google Scholar] [CrossRef]
  18. Torres, D.; Crichigno, J.; Padilla, G.; Rivera, R. Scheduling coupled photovoltaic, battery and conventional energy sources to maximize profit using linear programming. Renew. Energy 2014, 72, 284–290. [Google Scholar] [CrossRef] [Green Version]
  19. Dao, V.T.; Ishii, H.; Takenobu, Y.; Yoshizawa, S.; Hayashi, Y. Intensive quadratic programming approach for home energy management systems with power utility requirements. Int. J. Electr. Power Energy Syst. 2020, 115, 105473. [Google Scholar] [CrossRef]
  20. Wu, X.; Hu, X.; Yin, X.; Zhang, C.; Qian, S. Optimal battery sizing of smart home via convex programming. Energy 2017, 140, 444–453. [Google Scholar] [CrossRef]
  21. Li, H.; Zeng, P.; Zang, C.; Yu, H.; Li, S. An Integrative DR Study for Optimal Home Energy Management Based on Approximate Dynamic Programming. Sustainability 2017, 9, 1248. [Google Scholar] [CrossRef] [Green Version]
  22. Javadi, M.S.; Nezhad, A.E.; Nardelli, P.H.J.; Gough, M.; Lotfi, M.; Santos, S.; Catalão, J.P.S. Self-scheduling model for home energy management systems considering the end-users discomfort index within price-based demand response programs. Sustain. Cities Soc. 2021, 68, 102792. [Google Scholar] [CrossRef]
  23. Anvari-Moghaddam, A.; Monsef, H.; Rahimi-Kian, A. Optimal Smart Home Energy Management Considering Energy Saving and a Comfortable Lifestyle. IEEE Trans. Smart Grid 2015, 6, 324–332. [Google Scholar] [CrossRef]
  24. Qais, M.; Abdulwahid, Z. A new method for improving particle swarm optimization algorithm (TriPSO). In Proceedings of the 2013 5th International Conference on Modeling, Simulation and Applied Optimization (ICMSAO), Hammamet, Tunisia, 28–30 April 2013; pp. 1–6. [Google Scholar] [CrossRef]
  25. El Makroum, R.; Khallaayoun, A.; Lghoul, R.; Mehta, K.; Zörner, W. Home Energy Management System Based on Genetic Algorithm for Load Scheduling: A Case Study Based on Real Life Consumption Data. Energies 2023, 16, 2698. [Google Scholar] [CrossRef]
  26. Wang, X.; Mao, X.; Khodaei, H. A multi-objective home energy management system based on internet of things and optimization algorithms. J. Build. Eng. 2021, 33, 101603. [Google Scholar] [CrossRef]
  27. Reghukumar, R.; Sambhu, S.; Ravikumar Pandi, V. Multi-Objective Optimization for Efficient Home Energy Management System using Differential Evolution Algorithm. In Proceedings of the 2018 3rd IEEE International Conference on Recent Trends in Electronics, Information & Communication Technology (RTEICT), Bangalore, India, 18–19 May 2018; pp. 1157–1162. [Google Scholar] [CrossRef]
  28. Isa, N.M.; Wei, T.C.; Yatim, A.H.M. Energy management system employing harmony search algorithm for hybrid cogeneration. In Proceedings of the 5th IET International Conference on Clean Energy and Technology (CEAT2018), Kuala Lumpur, Malaysia, 5–6 September 2018; pp. 1–7. [Google Scholar] [CrossRef]
  29. Khan, F.A.; Ullah, K.; ur Rahman, A.; Anwar, S. Energy optimization in smart urban buildings using bio-inspired ant colony optimization. Soft Comput. 2023, 27, 973–989. [Google Scholar] [CrossRef]
  30. Ayub, S.; Ayob, S.M.; Tan, C.W.; Ayub, L.; Bukar, A.L. Optimal residence energy management with time and device-based preferences using an enhanced binary grey wolf optimization algorithm. Sustain. Energy Technol. Assess. 2020, 41, 100798. [Google Scholar] [CrossRef]
  31. Ahmed, M.S.; Mohamed, A.; Khatib, T.; Shareef, H.; Homod, R.Z.; Ali, J.A. Real time optimal schedule controller for home energy management system using new binary backtracking search algorithm. Energy Build. 2017, 138, 215–227. [Google Scholar] [CrossRef]
  32. Drir, N.; Chekired, F.; Rekioua, D. An integrated neural network for the dynamic domestic energy management of a solar house. Int. Trans. Electr. Energy Syst. 2021, 31, e13227. [Google Scholar] [CrossRef]
  33. Radha, K.S.; Priya, R.; Jeevitha, K. Energy Management based on K-Nearest Neighbour Approach in Residential Application. In Proceedings of the 2023 Third International Conference on Artificial Intelligence and Smart Energy (ICAIS), Coimbatore, India, 2–4 February 2023; pp. 966–971. [Google Scholar]
  34. Langer, L.; Volling, T. A reinforcement learning approach to home energy management for modulating heat pumps and photovoltaic systems. Appl. Energy 2022, 327, 120020. [Google Scholar] [CrossRef]
  35. Jindal, A.; Kumar, N.; Singh, M. Internet of energy-based demand response management scheme for smart homes and PHEVs using SVM. Futur. Gener. Comput. Syst. 2020, 108, 1058–1068. [Google Scholar] [CrossRef]
  36. Cao, Z.; Han, X.; Lyons, W.; O’Rourke, F. Energy management optimisation using a combined Long Short-Term Memory recurrent neural network—Particle Swarm Optimisation model. J. Clean. Prod. 2021, 326, 129246. [Google Scholar] [CrossRef]
  37. Qais, M.H.; Muyeen, S.M. A Novel Adaptive Filtering Algorithm Based Parameter Estimation Technique for Photovoltaic System. IEEE Trans. Energy Convers. 2022, 37, 286–294. [Google Scholar] [CrossRef]
  38. Alqaili, A.; Qais, M.; Al-Mansour, A. Integer Search Algorithm: A New Discrete Multi-Objective Algorithm for Pavement Maintenance Management Optimization. Appl. Sci. 2021, 11, 7170. [Google Scholar] [CrossRef]
Figure 1. Home energy structure.
Figure 1. Home energy structure.
Sustainability 15 09193 g001
Figure 2. Flowchart of optimal home energy management.
Figure 2. Flowchart of optimal home energy management.
Sustainability 15 09193 g002
Figure 3. Comfort working time range for household appliances.
Figure 3. Comfort working time range for household appliances.
Sustainability 15 09193 g003
Figure 4. Random load profile for a residential consumer.
Figure 4. Random load profile for a residential consumer.
Sustainability 15 09193 g004
Figure 5. Solar irradiation and ambient temperature in Hong Kong on 1 January 2021.
Figure 5. Solar irradiation and ambient temperature in Hong Kong on 1 January 2021.
Sustainability 15 09193 g005
Figure 6. Energy generation and load demand for scenario 1.
Figure 6. Energy generation and load demand for scenario 1.
Sustainability 15 09193 g006
Figure 7. Energy generation and load demand for scenario 2.
Figure 7. Energy generation and load demand for scenario 2.
Sustainability 15 09193 g007
Figure 8. Convergence of the minimization of the objective function.
Figure 8. Convergence of the minimization of the objective function.
Sustainability 15 09193 g008
Figure 9. Energy generation and load demand for scenario 3.
Figure 9. Energy generation and load demand for scenario 3.
Sustainability 15 09193 g009
Table 1. Scenarios of home energy management.
Table 1. Scenarios of home energy management.
ScenarioEnergy SourceOptimal Schedule
# 1PV and Gridx
# 2PV and Battery and Gridx
# 3PV and Battery and Grid
Table 2. Total bought and sold energy daily from and to the grid for scenario 1.
Table 2. Total bought and sold energy daily from and to the grid for scenario 1.
Scenario #1Energy (kWh)Cost (HKD/Day)
To grid23.099007034166810115.495
From grid23.18131442649991027.539
Table 3. Total bought and sold energy daily to and from the grid for scenario 2.
Table 3. Total bought and sold energy daily to and from the grid for scenario 2.
Scenario #2Energy (kWh)Cost (HKD/Day)
To grid11.80159.01
From grid6.6075.37
Table 4. Total bought and sold energy per day from and to the grid for scenario 3.
Table 4. Total bought and sold energy per day from and to the grid for scenario 3.
Scenario #3Energy (kWh)Cost (HKD/Day)
To grid13.58951367.947567
From grid5.884774.01236
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Qais, M.; Loo, K.H.; Hasanien, H.M.; Alghuwainem, S. Optimal Comfortable Load Schedule for Home Energy Management Including Photovoltaic and Battery Systems. Sustainability 2023, 15, 9193. https://doi.org/10.3390/su15129193

AMA Style

Qais M, Loo KH, Hasanien HM, Alghuwainem S. Optimal Comfortable Load Schedule for Home Energy Management Including Photovoltaic and Battery Systems. Sustainability. 2023; 15(12):9193. https://doi.org/10.3390/su15129193

Chicago/Turabian Style

Qais, Mohammed, K. H. Loo, Hany M. Hasanien, and Saad Alghuwainem. 2023. "Optimal Comfortable Load Schedule for Home Energy Management Including Photovoltaic and Battery Systems" Sustainability 15, no. 12: 9193. https://doi.org/10.3390/su15129193

APA Style

Qais, M., Loo, K. H., Hasanien, H. M., & Alghuwainem, S. (2023). Optimal Comfortable Load Schedule for Home Energy Management Including Photovoltaic and Battery Systems. Sustainability, 15(12), 9193. https://doi.org/10.3390/su15129193

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop