Article

Implementation of ANN-Based Auto-Adjustable for a Pneumatic Servo System Embedded on FPGA

by
Marco-Antonio Cabrera-Rufino
*,†,
Juan-Manuel Ramos-Arreguín
*,†,
Juvenal Rodríguez-Reséndiz
,
Efren Gorrostieta-Hurtado
and
Marco-Antonio Aceves-Fernandez
Facultad de Ingeniería, Universidad Autónoma de Querétaro, Cerro de las Campanas, Las Campanas, Queretaro 76010, Mexico
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Micromachines 2022, 13(6), 890; https://doi.org/10.3390/mi13060890
Submission received: 16 May 2022 / Revised: 28 May 2022 / Accepted: 28 May 2022 / Published: 31 May 2022
(This article belongs to the Section E:Engineering and Technology)

Abstract

:
Artificial intelligence techniques for pneumatic robot manipulators have become of deep interest in industrial applications, such as non-high voltage environments, clean operations, and high power-to-weight ratio tasks. The principal advantages of this type of actuator are the implementation of clean energies, low cost, and easy maintenance. The disadvantages of working with pneumatic actuators are that they have non-linear characteristics. This paper proposes an intelligent controller embedded in a programmable logic device to minimize the non-linearities of the air behavior into a 3-degrees-of-freedom robot with pneumatic actuators. In this case, the device is suitable due to several electric valves, direct current motors signals, automatic controllers, and several neural networks. For every degree of freedom, three neurons adjust the gains for each controller. The learning process is constantly tuning the gain value to reach the minimum of the mean square error. Results plot a more appropriate behavior for a transitive time when the neurons work with the automatic controllers with a minimum mean error of ± 1.2 mm.

1. Introduction

The employment of pneumatic actuators in the robotic field has great importance in the manufacturing industry and the modern design of controllers [1,2]. Its significant advantages are a low-cost, lightweight, and simple design. The disadvantages are the highly non-linear behavior of the pneumatic actuators due to having the air as a means of generating force, e.g., the flow of air into the valves is not uniform, friction in the joints, and delay in air propagation, among others [3,4,5,6,7].
Artificial neural networks (ANN), fuzzy logic, genetic algorithms, and others are practical when the mathematical model of the dynamic system is highly complex, highly non-linear, or impossible to know due to the lack of knowledge, except for a few known variables [8,9,10,11,12,13].
Programmable hardware devices, like FPGA, are suitable for hardware implementation of neural networks and PID controllers. They have the advantage of better accuracy, repeatability, and lower noise sensitivity. Also, it is compatible with other types of pre-processors [14,15,16,17].
This work aims to position a 3 DoF robot arm with pneumatic actuators and implement an ANN-based auto-adjustable gain tuner for PID controllers. The main contribution is an algorithm proposal to control each DoF of the pneumatic actuators embedded in reconfigurable hardware.
The pneumatic robot arm has six DoF, as presented in Figure 1, where θ 1 , θ 2 , and θ 3 are the respective angle for each DoF. The moving forces are supplied by one pneumatic motor and two pneumatic pistons.
To convert a PID design into its VHDL code, we implement Octave software for this work. For example, we set PID gains as integer inputs, and the output is in binary fixed-point format.

Findings

Table 1 shows a brief comparison of the implementations and contributions of state of the art. It mentions the hardware-implemented, and all these works are focused on pneumatic actuators.
The prototype architecture proposed has several problems, such as frictions in the joints and the non-linearity inevitably produced by the compressibility of the air. Airflow is not constant and experiences a delay in propagating through the system [3]. The lack of precision could cause catastrophic events that would affect the robot’s task and even harm workers [20].
The proposed robot controller remarkably has a slightly more accurate performance, adequately reducing alterations because of the non-linearities of the pneumatic actuators.
The order of this work is as follows: Section 2 deeply describes the materials and methodology, including the hardware description of the PID controller, the configuration of the encoder, and mainly the ANN. Section 3 presents the results obtained for the PID controllers of the motors and the ANN auto-adjustable gains for the pneumatic actuators controller. Section 4 is the discussion of results and their limitations. Finally, Section 5 gives the conclusions of this investigation.

2. Materials and Methods

This section presents the materials and methodology used in this work, such as inverse kinematics, the instrumentation of the encoders, the design of PID controllers and artificial neural networks, and some mathematical tools that helped us develop the before mentioned.

2.1. Materials

In this work, we used 24-VDC and 12-VDC power supplies. An FPGA was the core of this project and also a laptop for data acquisition, Octave script development, and FPGA programming. Eighteen optocouplers isolated the FPGA control signals from the motor drivers to prevent electric noise, and six solid-state relays activated the 12-VDC electro-valves. The motors adjusted the airflow through the pneumatic actuators. The pneumatic electro-valves controlled the direction movement of the links of the robot. Figure 2 illustrates all these components

2.2. Inverse Kinematics of a 3 DoF Robot

Figure 3 depicts a geometrical model of a 3-DoF robot, and it provides information to compute the final position x 1 , y 1 , z 1 of the robot [18], where:
  • l 1 , l 2 , l 3 → are the links of the robot.
  • θ 1 → is the angle of link l 1 with respect to Y axis.
  • θ 2 → is the angle of link l 2 with respect to X Y axis.
  • θ 3 → is the angle of link l 3 with respect to X Y axis.
The inverse kinematic calculated the value of the angles θ 1 , θ 2 , and θ 3 needed to get the final position required x 1 , y 1 , z 1 . The Equations (1)–(3) represent the inverse kinematics of the robot [18].
θ 1 = t a n 1 y 1 x 1
θ 2 = c o s 1 x 2 + ( z l 1 ) 2 + l 2 2 l 3 2 2 l 2 x 2 + ( z l 1 ) 2 + s i n 1 z l 1 x 2 + ( z l 1 ) 2
θ 3 = θ 2 + c o s 1 l 3 2 + l 2 2 x 2 ( z l 1 ) 2 2 l 3 l 2 180

2.3. The Pneumatic System

Each DoF consists of one 5/3 electro-pneumatic valve, two airflow valves, two DC motors, and one incremental encoder that allowed us to get the arm position. In Figure 4, the schematic diagram of each DoF is drawn.

2.4. Structure Prototype for Airflow Control

We designed a mechanical base structure to couple the DC Motors to the airflow valves. A bell-type piece was attached to the motor stem. Moreover, it contains an internal hexagonal hole to fit the valve connection. Figure 5 depicts the integration of the mentioned parts.

2.5. Implemented Algorithm for Binarization of Variables

We developed Octave scripts to write VHDL code. They binarized numeric variables of logic signals, variables and constants, and LUTs faster. More helpful information about this is in [21].
For the binarization process, we used the fixed-point method. A fixed-point number in base-2 format is in (4).
i 2 i 1 i 0 · f 1 f 2 f 3 2
which is converted to a decimal number as in Equation (5).
i 2 · 2 2 + i 1 · 2 1 + i 0 · 2 0 + f 1 · 2 1 + f 2 · 2 2 + f 3 · 2 3
We wrote the Algorithm 1 on a laptop. The input is an integer or fractional variable. The same variable returned as a fixed-point output. b f = i + f , where i is the number of bits for the integer part, f for the fractional part, and b f is the total of bits used for that variable.
Algorithm 1: Binarization of a fixed-point variable.
A u x = v a r i a b l e × 2 f
if A u x < 0 then
   A u x = f l o o r ( 2 b f + A u x )
else
   A u x = f l o o r ( A u x )
end if
for i = b f : 1 : 1 do
   C o e f f _ b i n a r y i = A u x % 2
   A u x = f l o o r ( A u x i l i a r / 2 )
end for
A u x = v a r i a b l e × 2 f
The Coeff_binary variable is a matrix with 1 × b f size, bf is the number of zeros and ones stored in the matrix.

2.6. Design of the PID Algorithm

The continuous-time PID controller is given in (6). Its development and analysis are described in [22].
u ( t ) = K p e ( t ) + 1 T i 0 t e ( τ ) d τ + T d d e ( t ) d t
where u ( t ) is the control variable, and e ( t ) is the error. The error is the difference between the reference w ( t ) and the output y ( t ) . In Figure 6 a control system with the previous specifications is illustrated. The fundamental parameters of the PID controller are K p , T i , and T d .
The Laplace transform converts the Equations (6) to (7).
U ( s ) = K p 1 + 1 T i s + T d s E ( s )
where s typically represents the Laplace transform operator. From (7), the transfer function G ( s ) is in (8).
G ( s ) = U ( s ) E ( s ) = K p 1 + 1 T i s + T d s
The proportional, derivative, and integral components in (6) are discretized to get the PID controller. T 0 is the sample period. For this work, we use T 0 = 10 ms, and Equation (9) represents the derivative error.
d e d t e ( k ) e ( k 1 ) T 0 = Δ e ( k ) T 0
where e ( k ) is the error at the k-th sampling time, i.e., at t = k T 0 . The most convenient way to do the integral is by summing. Hence we approximate the continuous-time function by sampling using the direct trapezoidal method (see Figure 7). The integration of the error is computed with (10), and the discrete-time PID controller is (11).
0 t e ( τ ) d τ T 0 i = 1 k e ( i 1 )
u ( k ) = K p e ( k ) + T 0 T i i = 1 k e ( i 1 ) + T d T 0 e ( k ) e ( k 1 )
The Equation (11) reduce the computational time processing on the FPGA, resulting in (12). The constants q 1 , q 2 , and q 3 in Equation (13) are computed before the PID time process.
u ( k ) = q 1 e ( k ) + q 2 e ( k 1 ) + q 3 e ( k 2 ) + u ( k 1 )
q 1 = K p 1 + T 0 2 T i + T d T 0 q 2 = K p 1 T 0 2 T i + 2 T d T i q 3 = K p T d T 0
Based on (12), we performed an Octave script to generate the VHDL code for a PID controller. Figure 8 shows the architecture resulting, where the input signals are reset (RST), clock (CLK), setpoint (Sp), sampling time (Ts), actual position (Xin), and the constant values ( q 1 , q 2 , q 3 ). The output signal is yk and the sampling time was 10 ms.
Figure 8 is the PID block diagram for hardware configuration; the Register_PP_n module loads the input signal every period to compute the output yk. A subtraction module was applied to compute the actual error e k = s p x i n ; the q 1 , q 2 and q 3 signals are the controller constants. An adder module is used to compute y k r a w = q 1 e k + q 2 e k 2 + q 3 e k 3 + y k 1 , and four multipliers modules are implemented. The controller output signal y k is set to 18 bits.

2.7. PID Controller for the Airflow Valve

The arm position and speed are essential to perform the proper airflow control. The DC motors are linear systems that are practical to open or close the valve at the desired opening level to get the airflow required.
Based on Equations (12) and (13), Figure 9 shows the arm position and speed control proposal, where W p is the desired position, e p is the error position, u p is the control signal. We used a saturation block where W v is the saturation value and the maximum velocity desired. e v is the speed error, and u v is the control signal for the DC motor. The motor encoder sends position and speed feedback to the controller.

2.8. Encoder Instrumentation

The quadrature encoder module has two inputs, Channel A and B. DIR output signal gives the direction of the motor. ENA is active when a state changes on channels A and B. We implemented six flip-flops type D to catch the signals, one XOR Gate with two inputs for DIR output and another XOR gate with four inputs for ENA output. Figure 10 displays the architecture and the corresponding truth table of the encoder module.
Figure 11 presents the quadrature encoder instrumentation, written in Octave software. The motor channel inputs are A and B. Ts is the period signal. We set a counter for the pulses from the encoders for the speed. When the T s signal activates the rising edge module, the counter value is saved, and it is reset to start over. In Figure 11, outputs are drawn. The vel_nom and pos_nom are the raw values of the velocity and position. These have 16 bits.
The third output signal represents the normalized velocity. We obtained the value of the constant res_vel_norm in (14). Where v M A X = 108 R P M and N v = 3432 ppr, converted to 18 bits size. The vel_norm is the output of the normalized velocity given in the Equation (15).
r e s _ v e l _ n o r m = 60 V M A X × N v × T s
v e l _ n o r m = r e s _ v e l _ n o r m × v e l _ n o m
For the normalization of the position in 18 bits, we considered the maximum of 10 rotations of the flow control valve for its constant given in Equation (16). The pos_norm is the output of the normalized position in Equation (17).
r e s _ n o r m = 1 P M A X × N v × p o s _ n o m
p o s _ n o r m = r e s _ p o s _ n o m × r e s _ p o s

2.9. Neural Network Design

Artificial neurons are suitable for non-linear systems, providing continuous outputs, gathering signals available on their inputs, and assembling them according to their operational and intuitive activation. Figure 12 illustrates each neuron of a network. The multiple input signals coming from the external environment (specific application) are represented by the set x 1 , x 2 , x 3 , , x n [23].
The weighting carried out by the synaptic junctions of the network is implemented on the artificial neuron as a set of weights w 1 , w 2 , , w n . Analogously, the relevance of each of the x i inputs is measured by multiplying them by their corresponding weight w i , then weighting all the external information arriving at the neuron. Therefore, the neurons output is denoted by y, representing the weighted sum of its inputs. Equations (18) and (19) synthesize the result produced by the artificial neuron [24].
u = i = 1 n w i x i θ
y = g u
We trained the neurons by the method known as the backpropagation algorithm. By this method, we got the mean square error of the Equation (20).
E ( t ) = 1 2 e 2 ( t )

2.10. Neuron Learning Algorithm

The specific purpose of this design is to properly use perceptron neurons to tune the variables k p , T i , and T d of a digital PID controller in Equation (13). The objective is the mean square error, with a ± 0.5 tuning on each variable. These neurons are constantly learning. And the steps for the algorithm are the following [23].
  • The error signals e and Δ e in (21) and (22) are computed from the desired position for each of the robot joints q = ( θ 1 , θ 2 , θ 3 ) , and the actual position being measured of the system r = ( x 1 , x 2 , x 3 ) .
    e ( t ) = y ( t ) w ( t )
    Δ e ( t ) = e ( t 1 ) + e ( t )
    The error and derivative error are the inputs for each neuron. The description of this is in the Equation (23).
    X ( t ) = e ( t ) Δ e ( t )
  • Initialize w with small random values. For example w = 0.1 . We defined them in (24), and it represents the sum of the neuron weights in the first layer.
  • We set the learning rate to η = 0.99 . And the following steps are repeated permanently, and the neuron is constantly learning.
  • The s variable is computed in (24).
    s = w 1 e ( t ) + w 2 Δ e ( t )
  • The activation function, a sigmoid, of the intermediate neurons in (25) is computed, and Figure 13 is its representation.
    h = 0.5 1 + e s
  • The adaptive Equations (26) and (27) allowed the proportional coefficient K p values to be adjusted. We used a similar development to find the adjustment equations for T d and T i . The value η is the learning coefficient of the neural network and was 0.9.
    v ( t + 1 ) = v ( t ) + η e ( t ) 2 h
    w j ( t + 1 ) = w j ( t ) + η e ( t ) 2 v h ( 1 h ) x j
  • The proportional gain is denoted by the Equations (28) and (29), where v is the weight of the last neuron and h is the activation function.
    Δ K p = v h
    K p = K p + Δ K p
  • Return to step 4.
Figure 14 shows the design of the neurons for k p , and identical block diagrams are implemented for T d and T i . And they need to be initialized in this structural design. K p c , T i c , and T d c are the constant inputs. The Rising_edge and Latch modules detect the first pulse of the period signal T 0 , adding these variables to a summand that stores the initial value and updates the value of the kp, ti, and td variables. For Δ e k , a subtraction with a delay module is implemented to achieve Δ e ( k ) = e ( k 1 ) e ( k ) , for s signal two multipliers with an adder module were implemented for (24). To achieve (25) a LUT was implemented, and it contains 2 10 values between −1 to 1.
For v in Equation (25), a multiplication module with four inputs was implemented, and an adder with a period delay module to compute v ( k + 1 ) . For the values of the weights w 1 and w 2 another four variables multiplier was needed, the η e ( t ) 2 h factor in (25) was repeated for (26). A single multiplier is needed to calculate (27). The value of k p is constantly tuning, and k p c is the initial value of k p . To get k p an adder is implemented, summing Δ k p every period.
Finally, K p , T i , and T d are computed to obtain q 0 , q 1 , and q 2 in Equation (13), Figure 15 is this conversion.
Figure 16 presents the general diagram of a DoF, as it is observed inverse kinematics compute the desire angle values for a particular position of the end effector. Though only the second DoF is drawn, identical architecture was designed for the first and last DoF. According to e k signed value, the direction of the valve was chosen.
The FPGA resources implemented in the project are observed in Table 2. We spent almost half of the resources, but the multipliers, that our project used 100%.

3. Results

This section, first shows the flow air control signals, position, and speed, including simulations and experimental results. Then, a graph with a PID and Neuro-PID experimental results for comparison. After that, we plotted the results of the 3 DoF, and we included error and derivative error signals graphs.

3.1. DC Motors Control for Airflow

As a first step, controlling the airflow valves is necessary. The VDC motors are the appropriate actuators due to their linear behavior and easy tuning. Figure 17 plots the simulations of the position and speed. When the system starts, the motor reaches the maximum allowed speed; it tends to be zero once it gets to the desired position. Figure 18 contains the experimental results, which are similar to those simulated. The sample timeairflows. As the air flow valves have ten spins maximum, the top position is 63 rads. The full speed of the motors is 210 RPM, which means 22 rad/s.
We first considered a Texas Instruments DSP for the experimental results, which gave excellent results. However, PID controllers and neural networks needed a fast response due to the number of encoders. We decided to switch to the FPGA, a device that can perform all these processes in parallel. For these results, the position PID parameters are q 0 = 0.1030 , q 1 = 0.0949 , and q 2 = 0.003 , for speed q 0 = 0.0770 , q 1 = 0.0140 , and q 2 = 0.007 .

3.2. PID vs. Neuro-PID Controller

Once the robotic arm was configured, we performed tests with the designed controllers. For the PID and Neuro-PID gains, we are using the heuristic method, and the gain adjustment was performed by experimental tests. Figure 19 and the blue line is the classic PID controller. The red line is the Neuro-PID controller, which has a particular behavior with a faster response time, a little less overshoot, and reaches the steady-state before the typical PID. Table 3 displays the transient response specifications of these controllers.
We observed that the intelligent controller has some disturbances, possibly due to the adjustment of the variable K p . For this test, we set K p = 2.5 , T i = 0.98 , and T d = 0 . In addition, for this and the following tests, the position and velocity variables were normalized. The maximum value of the signals is equal to one; this helps to use the computational resources better.

3.3. Positioning for the 3 DoF Links

The graph of the first DoF is in Figure 20. This is the one controlled by the pneumatic motor. Within these tests, this was the easiest to tune. It performs well, even when moving in conjunction with the other two DoFs.
Figure 21 and Figure 22 plot the second and third DoFs. These are controlled by the pistons located on the robot. Their tuning was more complex than the first one. In the second DoF, there are disturbances, but it is possible to tune to the marked reference. The third one was the most difficult to implement.
Figure 23 plots the error signal in blue color, the derivative error in red color. These signals are important for the PID and Neural network modules, and the error at steady-state is 1.2 mm.

4. Discussion

The proposed model has been developed to be applied to a 3 DoF pneumatic robot. The model uses three optical encoders with 1000 pulses by turn. Therefore, the resolution of the movement arm is 6.28 mrad. A limitation of the model is that the arm only has 120° to turn. That is due to the mechanical limitations.
The flow control is implemented with electrical motors coupled with flow control valves. Each motor for the air valve uses an encoder to know the state of the valve (open, close, and intermediate level). The DC motors use an electromagnetic encoder with 3432 pulses by turn. A limitation of the model is that we need two DC motors with encoders and their hardware to control them. In consequence, the model requires 6 DC motors with an encoder.
The implemented model must consider the hardware implementation for nine encoders, 3 PID control algorithms, 3 ANN algorithms, and the external logical signals used were 50 pins. We are using the following hardware of the FPGA D0-Nano board: 45% elements, 1671 registers, 32% pins, and 100% of the 9 bits multipliers.
In Section 3, according to Table 3 and Figure 19, we can observe that the Neuro-PID algorithm requires less rise time, overshoot, and settling time. The error is similar in both cases, but we consider that the ANN-PID algorithm has a better behavior than a simple PID. The limitation of the algorithm is the disturbances observed in Figure 19 on the Neuro-PID graph.
The disturbances in ANN-PID are due to the self-tuning process of the ANN algorithm to obtain the appropriate gains for the corresponding arm. One of the advantages of this process is that in the event of any disturbance that occurs in the arm positioning, the system will automatically respond to adjust itself. Moreover, the system has the advantage that if you change the weight being moved or add weight to one of the arms, the system responds by adjusting gains accordingly.

5. Conclusions

This work had three phases. The first one was the airflow control through the pneumatic system; although we did not control the air pressure directly, the positioning of the motors is adequate for its regulation. We performed the first tests on development boards based on microcontrollers. The motor speed control is considered for this design to avoid abrupt airflows. Figure 18a, shows the position of DC motor control, with an error of less than 0.01 rad. Moreover, Figure 18b represents the speed control, with an error of ± 0.5 rad/s. In this phase, the goal was achieved, With accurate position control and the speed controlled at slow or medium values.
The second phase was the control design for 1 DoF. This step was performed entirely in VHDL. Moreover, in this phase, the results in Figure 19 show a better performance when the neural network was active, improving the overshoot, response time, and reaching the steady state. We got a minimum error of 1.2 mm in the steady-state. The results in this phase were satisfactory.
The last phase is the implementation of the 3 DoFs. Results in Figure 20, Figure 21 and Figure 22 show that the last two DoF were positioned to the desired position and had an error of 2 mm. We concluded that these results were acceptable. In future work, We consider implementing algorithms with fuzzy logic, neuro-fuzzy, and ANFIS.

Author Contributions

Conceptualization, M.-A.C.-R. and J.-M.R.-A.; methodology, M.-A.C.-R., J.R.-R. and M.-A.A.-F.; formal analysis E.G.-H. and M.-A.A.-F.; writing—original draft preparation, M.-A.C.-R. and J.-M.R.-A.; writing—review and editing, M.-A.C.-R., J.R.-R. and J.-M.R.-A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received funding from CONACYT.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
DoFDegree of freedom
LUTLook-Up Table
PIDProportional, integral, and differential control
ANNArtificial Neural Network
FPGAField Programming Gate Array
VHDLVery High-Speed Integrated Circuit Hardware Description Language
DSPDigital Signal Processing
DCDirect Current
VDCVolts of Direct Current
VACVolts of alternating Current
ANFISAdaptive neuro-fuzzy inference system

References

  1. Ali, H.; Noor, S.; Bashi, S.; Marhaban, M. A review of pneumatic actuators (modeling and control). Aust. J. Basic Appl. Sci. 2009, 3, 440–454. [Google Scholar]
  2. Singh, S.; Kishore, K.; Akbar, S.A. Neuro-evolutionary based controller design for linear and non-linear systems. In Proceedings of the 2021 21st International Conference on Control, Automation and Systems (ICCAS), Jeju, Korea, 12–15 October 2021; pp. 211–215. [Google Scholar] [CrossRef]
  3. Miramontes, F.; Soto, J. Modelación de la Operación Neumática de un Brazo Manipulador. Congr. Nac. Robót. 2003, 2, 2. [Google Scholar]
  4. Sorli, M.; Gastaldi, L.; Codina, E.; Heras, S. Dynamic analysis of pneumatic actuators. Simul. Pract. Theory 1999, 7, 589–602. [Google Scholar] [CrossRef]
  5. Wang, X.; Peng, G. Modeling and control for pneumatic manipulator based on dynamic neural network. SMC’03 Conference Proceedings. In Proceedings of the 2003 IEEE International Conference On Systems, Man And Cybernetics. Conference Theme-System Security And Assurance (Cat. No. 03CH37483), Washington, DC, USA, 5–8 October 2003; Volume 3, pp. 2231–2236. [Google Scholar]
  6. Rouzbeh, B.; Bone, G.; Ashby, G. High-accuracy position control of a rotary pneumatic actuator. IEEE/ASME Trans. Mechatronics 2018, 23, 2774–2781. [Google Scholar] [CrossRef]
  7. Lin, C.; Sie, T.; Chu, W.; Yau, H.; Ding, C. Tracking control of pneumatic artificial muscle-activated robot arm based on sliding-mode control. Actuators 2021, 10, 66. [Google Scholar] [CrossRef]
  8. Khanafer, M.; Shirmohammadi, S. Applied AI in instrumentation and measurement: The deep learning revolution. IEEE Instrum. Meas. Mag. 2020, 23, 10–17. [Google Scholar] [CrossRef]
  9. Rodriguez-Abreo, O.; Rodriguez-Resendiz, J.; Fuentes-Silva, C.; Hernández-Alvarado, R.; Falcon, M. Self-Tuning Neural Network PID with Dynamic Response Control. IEEE Access 2021, 9, 65206–65215. [Google Scholar] [CrossRef]
  10. Rodríguez-Abreo, O.; Garcia-Guendulain, J.; Hernández-Alvarado, R.; Flores-Rangel, A.; Fuentes-Silva, C. Genetic algorithm-based tuning of backstepping controller for a quadrotor-type unmanned aerial vehicle. Electronics 2020, 9, 1735. [Google Scholar] [CrossRef]
  11. Rodríguez-Abreo, O.; Ornelas-Rodíguez, F.; Ramírez-Pedraza, A.; Hurtado-Ramos, J.; González-Barbosa, J. Backstepping control for a UAV-manipulator tuned by Cuckoo Search algorithm. Robot. Auton. Syst. 2022, 147, 103910. [Google Scholar] [CrossRef]
  12. Hesselroth, T.; Sarkar, K.; Van Der Smagt, P.; Schulten, K. Neural network control of a pneumatic robot arm. IEEE Trans. Syst. Man Cybern. 1994, 24, 28–38. [Google Scholar] [CrossRef] [Green Version]
  13. Alshareefi, H.; Lupu, C.; Olteanu, S.; Ismail, L. Design and Simulation of Adaptive Neuro-Fuzzy Inference System Inverse Controller for a Coupled Tank System. In Proceedings of the 2021 10th International Conference on Energy and Environment (CIEM), Bucharest, Romania, 14–15 October 2021; pp. 1–5. [Google Scholar]
  14. Gillespie, M.; Best, C.; Townsend, E.; Wingate, D.; Killpack, M. Learning non-linear dynamic models of soft robots for model predictive control with neural networks. In Proceedings of the 2018 IEEE International Conference On Soft Robotics (RoboSoft), Livorno, Italy, 24–28 April 2018; pp. 39–45. [Google Scholar]
  15. Mourad, A.; Zennir, Y. Fuzzy-PI Controller Tuned with HBBO for 2 DOF Robot Trajectory Control. Eng. Proc. 2022, 14, 10. [Google Scholar] [CrossRef]
  16. Subramanian, S.; Mohan, R.; Shanmugam, S.; Bacanin, N.; Zivkovic, M.; Strumberger, I. Speed control and quantum vibration reduction of Brushless DC Motor using FPGA based Dynamic Power Containment Technique. J. Ambient. Intell. Humaniz. Comput. 2021, 12, 1–15. [Google Scholar] [CrossRef]
  17. Muthuramalingam, A.; Himavathi, S.; Srinivasan, E. Neural network implementation using FPGA: Issues and application. Int. J. Inf. Technol. 2008, 4, 86–92. [Google Scholar]
  18. Sánchez-Solar, S.; Rivas-Araiza, E.; Gorrostieta-Hurado, E.; Ramos-Arreguín, J. Simulation of a two DOF pneumatic manipulator robot using control based on back propagation neural network. In Proceedings of the 2017 International Conference On Electronics, Communications And Computers (CONIELECOMP), Cholula, Mexico, 22–24 February 2017; pp. 1–8. [Google Scholar]
  19. Humaidi, A.; Ibraheem, I.; Azar, A.; Sadiq, M. A new adaptive synergetic control design for single link robot arm actuated by pneumatic muscles. Entropy 2020, 22, 723. [Google Scholar] [CrossRef] [PubMed]
  20. Sünderhauf, N.; Brock, O.; Scheirer, W.; Hadsell, R.; Fox, D.; Leitner, J.; Upcroft, B.; Abbeel, P.; Burgard, W.; Milford, M.; et al. The limits and potentials of deep learning for robotics. Int. J. Robot. Res. 2018, 37, 405–420. [Google Scholar] [CrossRef] [Green Version]
  21. Gazi, O. A Tutorial Introduction to VHDL Programming; Springer: Berlin/Heidelberg, Germany, 2019. [Google Scholar]
  22. Bobál, V.; Böhm, J.; Fessl, J.; Macháček, J. Self-Tuning PID Controllers; Springer: Berlin/Heidelberg, Germany, 2005. [Google Scholar]
  23. Silva, I.; Spatti, D.; Flauzino, R.; Liboni, L.; Alves, S. Artificial Neural Networks: A Practical Course; Springer International Publishing: Cham, Switzerland, 2017. [Google Scholar]
  24. Gorrostieta, E.; Vargas, E.; Aguado, A. A neuro PD control applied for free gait on a six legged robot. WSEAS Trans. Comput. 2004, 3, 612–618. [Google Scholar]
Figure 1. Pneumatic robot prototype with 6 DoF.
Figure 1. Pneumatic robot prototype with 6 DoF.
Micromachines 13 00890 g001
Figure 2. Diagram block of all materials used for this project.
Figure 2. Diagram block of all materials used for this project.
Micromachines 13 00890 g002
Figure 3. Geometrical model of a 3-DoF robot.
Figure 3. Geometrical model of a 3-DoF robot.
Micromachines 13 00890 g003
Figure 4. Schematic of one DoF pneumatic system.
Figure 4. Schematic of one DoF pneumatic system.
Micromachines 13 00890 g004
Figure 5. Airflow control system valve with plastic base for DC motors.
Figure 5. Airflow control system valve with plastic base for DC motors.
Micromachines 13 00890 g005
Figure 6. Block diagram of a control system [22].
Figure 6. Block diagram of a control system [22].
Micromachines 13 00890 g006
Figure 7. The forward trapezoidal method.
Figure 7. The forward trapezoidal method.
Micromachines 13 00890 g007
Figure 8. VHDL diagram block for PID controller. The symbol * in this figure represents a multiplier module.
Figure 8. VHDL diagram block for PID controller. The symbol * in this figure represents a multiplier module.
Micromachines 13 00890 g008
Figure 9. Diagram block for the motors PID controller.
Figure 9. Diagram block for the motors PID controller.
Micromachines 13 00890 g009
Figure 10. Encoder module functionality.
Figure 10. Encoder module functionality.
Micromachines 13 00890 g010
Figure 11. VHDL diagram block for the encoder configurations. The symbol * in this figure represents a multiplier module.
Figure 11. VHDL diagram block for the encoder configurations. The symbol * in this figure represents a multiplier module.
Micromachines 13 00890 g011
Figure 12. Artificial neural network.
Figure 12. Artificial neural network.
Micromachines 13 00890 g012
Figure 13. The sigmoid function.
Figure 13. The sigmoid function.
Micromachines 13 00890 g013
Figure 14. NNET module, neuro tuning variable for k p . The symbol * in this figure represents a multiplier module.
Figure 14. NNET module, neuro tuning variable for k p . The symbol * in this figure represents a multiplier module.
Micromachines 13 00890 g014
Figure 15. The calculation for q 0 , q 1 , and q 2 .
Figure 15. The calculation for q 0 , q 1 , and q 2 .
Micromachines 13 00890 g015
Figure 16. General diagram for a DoF.
Figure 16. General diagram for a DoF.
Micromachines 13 00890 g016
Figure 17. Simulated results for position and velocity control of DC motors where the blue lines are the setpoint and red ones the control signals. (a) Position plot. (b) Velocity plot.
Figure 17. Simulated results for position and velocity control of DC motors where the blue lines are the setpoint and red ones the control signals. (a) Position plot. (b) Velocity plot.
Micromachines 13 00890 g017
Figure 18. Experimental results for position and velocity control of DC motorswhere the blue lines are the setpoint and red ones the control signals. (a) Position plot. (b) Velocity plot.
Figure 18. Experimental results for position and velocity control of DC motorswhere the blue lines are the setpoint and red ones the control signals. (a) Position plot. (b) Velocity plot.
Micromachines 13 00890 g018
Figure 19. Experimental results for PID (blue) vs. Neuro-PID (red) controller for a DoF.
Figure 19. Experimental results for PID (blue) vs. Neuro-PID (red) controller for a DoF.
Micromachines 13 00890 g019
Figure 20. Experimental results for the first DoF. The Setpoint signal is colored in red, control signal in blue.
Figure 20. Experimental results for the first DoF. The Setpoint signal is colored in red, control signal in blue.
Micromachines 13 00890 g020
Figure 21. Experimental results for the second DoF. The Setpoint signal is colored in red, control signal in blue.
Figure 21. Experimental results for the second DoF. The Setpoint signal is colored in red, control signal in blue.
Micromachines 13 00890 g021
Figure 22. Experimental results for the third DoF. The Setpoint signal is colored in red, control signal in blue.
Figure 22. Experimental results for the third DoF. The Setpoint signal is colored in red, control signal in blue.
Micromachines 13 00890 g022
Figure 23. Experimental results for the error signal (blue) and derivative error (red) of a DoF.
Figure 23. Experimental results for the error signal (blue) and derivative error (red) of a DoF.
Micromachines 13 00890 g023
Table 1. State of the art.
Table 1. State of the art.
Ref, YearImplementationContribution
Sánchez, 2017 [18]A micro-computer with a graphical
simulator developed in C++
using OpenGL libraries
A simulated backpropagation artificial
neural network controller for a two
DoF pneumatic manipulator
Rousbeh, 2018 [6]PCI-6602 DAQ board
and a PC
The design of a controller and its
implementation on a position-controlled
rotary pneumatic actuator
Humaidi, 2020 [19]Computer simulation in
Matlab and Simulink
The design of a controller based on
the Synergetic Control theory concept
for a DoF robot arm powered by
pneumatic actuators
Lin, 2021 [7]myRio board and a PC
with Labview
A PID controller and a high-order
sliding-mode feedback
controller for a 3 DoF pneumatic
robot manipulator
Table 2. Total resources of the hardware implementation and its quantities.
Table 2. Total resources of the hardware implementation and its quantities.
Total ResourcesQuantity
Logic elements10,134/22,320 (45%)
Registers1671
Pins50/154 (32%)
Multipliers 9 bits132/132 (100%)
Table 3. Transient response specifications of PID and Neuro-PID controllers.
Table 3. Transient response specifications of PID and Neuro-PID controllers.
PIDNeuro-PID
K p = 2.5 , T d = 0 , and T i = 0.98
Rise time [s]0.610.33
Peak time [s]1.070.52
Overshoot [mm]39.136.3
Settling time [s]4.382.37
steady-state-error [mm]2.222.2
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Cabrera-Rufino, M.-A.; Ramos-Arreguín, J.-M.; Rodríguez-Reséndiz, J.; Gorrostieta-Hurtado, E.; Aceves-Fernandez, M.-A. Implementation of ANN-Based Auto-Adjustable for a Pneumatic Servo System Embedded on FPGA. Micromachines 2022, 13, 890. https://doi.org/10.3390/mi13060890

AMA Style

Cabrera-Rufino M-A, Ramos-Arreguín J-M, Rodríguez-Reséndiz J, Gorrostieta-Hurtado E, Aceves-Fernandez M-A. Implementation of ANN-Based Auto-Adjustable for a Pneumatic Servo System Embedded on FPGA. Micromachines. 2022; 13(6):890. https://doi.org/10.3390/mi13060890

Chicago/Turabian Style

Cabrera-Rufino, Marco-Antonio, Juan-Manuel Ramos-Arreguín, Juvenal Rodríguez-Reséndiz, Efren Gorrostieta-Hurtado, and Marco-Antonio Aceves-Fernandez. 2022. "Implementation of ANN-Based Auto-Adjustable for a Pneumatic Servo System Embedded on FPGA" Micromachines 13, no. 6: 890. https://doi.org/10.3390/mi13060890

APA Style

Cabrera-Rufino, M. -A., Ramos-Arreguín, J. -M., Rodríguez-Reséndiz, J., Gorrostieta-Hurtado, E., & Aceves-Fernandez, M. -A. (2022). Implementation of ANN-Based Auto-Adjustable for a Pneumatic Servo System Embedded on FPGA. Micromachines, 13(6), 890. https://doi.org/10.3390/mi13060890