Next Article in Journal
A Direct-Reading MEMS Conductivity Sensor with a Parallel-Symmetric Four-Electrode Configuration
Next Article in Special Issue
Vibrating Flexoelectric Micro-Beams as Angular Rate Sensors
Previous Article in Journal
Editorial for the Special Issue on Heat and Mass Transfer in Micro/Nanosystems
Previous Article in Special Issue
High-Frequency and Spectrum-Clean Shear-Horizontal Acoustic Wave Resonators with AlN Overlay
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Lai et al. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922

1
Department of Electronic Engineering, National Taiwan University of Science and Technology, No. 43, Sec. 4, Keelung Rd., Taipei 10607, Taiwan
2
Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, 1 Shuefu Rd., Neipu 91201, Pingtung, Taiwan
*
Authors to whom correspondence should be addressed.
Micromachines 2022, 13(7), 1152; https://doi.org/10.3390/mi13071152
Submission received: 13 July 2022 / Accepted: 14 July 2022 / Published: 21 July 2022
(This article belongs to the Special Issue Micro/Nano Resonators, Actuators, and Their Applications)
In the original publication [1], there was a mistake in Table 3, as published. The content of Table 3 was repeated with Table 4. The corrected Table 3 appears below.
The authors apologize for any inconvenience caused and state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.

Reference

  1. Lai, H.; Kuo, T.-N.; Xu, J.-Y.; Hsu, S.-H.; Hsu, Y.-C. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922. [Google Scholar] [CrossRef] [PubMed]
Table 3. The order shift distance and sensitivity for five different MRR radii under two cladding-layer refractive indices—1.31 and 1.312 for 1 dB/cm propagation loss.
Table 3. The order shift distance and sensitivity for five different MRR radii under two cladding-layer refractive indices—1.31 and 1.312 for 1 dB/cm propagation loss.
Propagation Loss: 1 dB/cm
R = 50 R = 75 R = 100 R = 125 R = 150
Order Shift Value (nm)SensitivityShift Value (nm)SensitivityShift Value (nm)SensitivityShift Value (nm)SensitivityShift Value (nm)Sensitivity
1135.367,650199.799,850264.8132,400327.6163,800392196,000
2262.8131,400391195,500521260,500647323,500774387,000
3387193,500577288,500780390,000965482,5001156578,000
4517258,500768.6384,3001026513,0001278.9639,450NANA
5642321,000956478,0001290645,000NANANANA
6774387,0001151575,5001553776,500NANANANA
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Lai, H.; Kuo, T.-N.; Xu, J.-Y.; Hsu, S.-H.; Hsu, Y.-C. Correction: Lai et al. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922. Micromachines 2022, 13, 1152. https://doi.org/10.3390/mi13071152

AMA Style

Lai H, Kuo T-N, Xu J-Y, Hsu S-H, Hsu Y-C. Correction: Lai et al. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922. Micromachines. 2022; 13(7):1152. https://doi.org/10.3390/mi13071152

Chicago/Turabian Style

Lai, Hsuan, Tzu-Ning Kuo, Jia-Yi Xu, Shih-Hsiang Hsu, and Yi-Cheng Hsu. 2022. "Correction: Lai et al. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922" Micromachines 13, no. 7: 1152. https://doi.org/10.3390/mi13071152

APA Style

Lai, H., Kuo, T. -N., Xu, J. -Y., Hsu, S. -H., & Hsu, Y. -C. (2022). Correction: Lai et al. Sensitivity Enhancement of Group Refractive Index Biosensor through Ring-Down Interferograms of Microring Resonator. Micromachines 2022, 13, 922. Micromachines, 13(7), 1152. https://doi.org/10.3390/mi13071152

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop