Article

Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer

1
Department of Radiation Oncology, Sapporo Teishinkai Hospital, Sapporo 065-0033, Japan
2
Department of Radiation Physics, Sapporo Teishinkai Hospital, Sapporo 065-0033, Japan
*
Author to whom correspondence should be addressed.
M.H., deceased 7 October 2021.
Cancers 2024, 16(2), 403; https://doi.org/10.3390/cancers16020403
Submission received: 13 December 2023 / Revised: 11 January 2024 / Accepted: 15 January 2024 / Published: 17 January 2024
(This article belongs to the Special Issue Prostate Cancer Radiotherapy: Recent Advances and Challenges)

Abstract

:

Simple Summary

The currently documented outcomes of proton therapy for patients with localized prostate cancer are based on passive scattering (PS). In this study, we compared the dose distribution of the line scanning (LS) method, one of the pencil beam scanning (PBS) techniques, with that of PS and volumetric modulated arc therapy (VMAT) in 30 patients. The results showed that LS could significantly reduce the wide range of rectal and bladder doses compared to the PS and VMAT while upholding the requisite target dose. The results suggest that proton therapy for prostate cancer with the PBS method may have the potential to reduce toxicities further while preserving therapeutic efficacies.

Abstract

Background: The proton irradiation modality has transitioned from passive scattering (PS) to pencil beam scanning. Nevertheless, the documented outcomes predominantly rely on PS. Methods: Thirty patients diagnosed with prostate cancer were selected to assess treatment planning across line scanning (LS), PS, and volumetric modulated arc therapy (VMAT). Dose constraints encompassed clinical target volume (CTV) D98 ≥ 73.0 Gy (RBE), rectal wall V65 < 17% and V40 < 35%, and bladder wall V65 < 25% and V40 < 50%. The CTV, rectal wall, and bladder wall dose volumes were calculated and evaluated using the Freidman test. Results: The LS technique adhered to all dose limitations. For the rectal and bladder walls, 10 (33.3%) and 21 (70.0%) patients in the PS method and 5 (16.7%) and 1 (3.3%) patients in VMAT, respectively, failed to meet the stipulated requirements. The wide ranges of the rectal and bladder wall volumes (V10-70) were lower with LS than with PS and VMAT. LS outperformed VMAT across all dose–volume rectal and bladder wall indices. Conclusion: The LS method demonstrated a reduction in rectal and bladder doses relative to PS and VMAT, thereby suggesting the potential for mitigating toxicities.

1. Introduction

Radiotherapy is one of the radical treatments for patients with localized prostate cancer. The curability of radiotherapy for localized prostate cancer is comparable to that of surgery [1,2]. Various methods of radiation therapy coexist, including X-ray therapy, brachytherapy, proton therapy, and carbon beam therapy. In common with these radiotherapy methods, to achieve both high curability and low rates of toxicity, it is essential to concentrate the dose on the target volume and reduce the dose to surrounding organs at risk (OARs). High-dose X-ray therapy using intensity-modulated radiation therapy (IMRT) is currently considered one of the standard radiotherapies for prostate cancer [3].
Given the physical characteristics of the Bragg peak, proton therapy can, in principle, better reduce the dose to OARs than X-ray-based techniques [4]. Proton therapy has been used to treat localized prostate cancer for the past 20 years. Recently, several studies have reported proton therapy results for localized prostate cancer, all of which showed favorable biochemical control and low rates of late gastrointestinal (GI) and genitourinary (GU) toxicities [5,6,7,8,9]. It is significant to note, however, that these results were all obtained with the technique of passive scattering (PS).
The current proton therapy technology is gradually shifting from PS to pensile beam scanning (PBS) methods that were developed to achieve more efficient dose delivery of protons [10]. PBS is a new proton irradiation method that has rapidly been adopted worldwide. Proton therapy’s fundamental concept was proposed in the 1940s [11]. In the 1990s, the first clinical proton therapy system was introduced in a hospital [12]. The PS technique was used in early facilities to provide proton treatment. The technical foundation for the PBS method, a novel proton irradiation technique, was developed in the 1980s [13]. The PBS method was used for the first time in Japan in the 2010s and is currently available throughout many regions, including Europe and the US [14]. As of 2023, 11 out of 19 facilities in Japan have started to perform proton therapy using the scanning method.
In theory, the PBS method, including line scanning (LS), can provide more localized dose distribution than the PS method, which is expected to improve prostate cancer treatment outcomes. However, due to the indolent nature of prostate cancer, the long-term outcomes of the PBS method have not yet been established. In addition, comparative studies of treatment plans involving either the scanning method or the PS method are limited.
In this study, we conducted a comparative study of treatment plans based on the hypothesis that the LS method for localized prostate cancer would reduce the dose to the rectum and bladder compared with the PS method and volumetric modulated arc therapy (VMAT).

2. Materials and Methods

2.1. Patients

Thirty patients who received proton therapy between January 2017 and March 2019 were selected at random for participation in this study. This study followed the standards of the Declaration of Helsinki and the current ethical guidelines and was approved by the XXXX Institutional Review Board (R030221). All patients were fully informed about this study and provided signed written consent forms.

2.2. Computed Tomography (CT) Simulation and Contouring

CT imaging was performed using a SOMATOM Perspective CT Scanner (SIEMENS, Munich, Germany), with each patient in the supine position with a full bladder. The patients’ trunks were immobilized using NB Bord ENB-16 immobilization shells (Engineering System Co., Ltd., Nagano, Japan). Their lower bodies were fixed by using an air mattress (Vac-Lock, CIVCO Medical Solutions, Kalana, IA, USA) to avoid fluctuations around the femoral head during treatment. CT images of 1.25 mm thickness were obtained. Magnetic resonance images were obtained in 3 mm slices in all patients. The bladder and rectum were aimed at in order to maintain the same conditions as in the planning CT. T2wi and T1Gd images were fused to the CT for treatment planning.
After the CT and MRI images were superimposed, contouring of the clinical target volume (CTV) and OARs was performed. The CTV was defined as the entire prostate and part of all seminal vesicles, depending on the risk classification. The 3 mm inner volumes of the entire bladder and the rectum within 10 mm in the SI direction of the CTV were defined as the bladder and rectal wall, respectively, and were used for evaluation in this study.

2.3. Dose Constraints

The prescribed dose for the CTV was standardized to 76.0 Gy or Gy RBE (relative biological effectiveness) in 38 fractionations. The RBE for proton therapy was defined as 1.1 for Co-60. The dose constraint was the same for all three treatments and was stipulated as follows: (1) CTV: D50 ≥ 76.0 Gy (RBE), D98 ≥ 73.0 Gy (RBE); (2) rectal wall: V65 < 17%, V40 < 35%; (3) bladder wall: V65 < 25%, V40 < 50%. Dx is defined as the dose received by x % of the organ volume. Vx is defined as the relative volume of the organ that received at least x Gy or Gy RBE.
In cases where the CTV dose constraints could be determined, the dose to the OARs was reduced. Our hospital started proton therapy using the wobbler method in 2016; in 2017, we changed to the scanning method. The definitions of contouring and dose constraints used in this study were those applied in the actual treatment of patients.

2.4. Treatment Equipment

The proton therapy system used (Sumitomo Heavy Industries, Ltd., Tokyo, Japan), which has an energy range of 70–230 MeV, was equipped with a universal nozzle that can switch between the PS and LS methods. Truebeam STx (Varian Medical Systems, Palo Alto, CA, USA) was used for the VMAT treatment. All three treatment plans were generated using Version 13.7 of Eclipse (Varian Medical Systems, Palo Alto, CA, USA).

2.4.1. LS Method

The LS method is one of the scanning methods used in proton therapy [15]. The equivalent depth of water from the body surface to the target in the direction of the treatment beam is calculated, and then the deepest slice is swept with the optimal proton energy. Subsequently, the proton energy is changed, and the dose is delivered to a shallower slice of it. These steps are repeated for all of the target cross-sections to form a spread-out Bragg peak (SOBP) [16].
Along with spot scanning and raster scanning, the LS method is one of the most commonly used PBS techniques [17]. These three methods differ in scan time, which may cause clinical problems in tumors with respiratory movement [18]. However, prostate cancer does not require consideration of the respiratory motion. We conducted this analysis with the assumption that the dose distribution of the LS technique might be representative of PBS.
The most crucial characteristic of proton beams is that they stop in the area/region they are supposed to, unlike penetrating X-rays. This characteristic, meanwhile, also adds to treatment uncertainty. Thus, range uncertainty must be considered in the treatment planning of proton therapy, particularly for the PBS method [19]. In this research, the LS method of treatment planning is based on robust optimization, which takes into account the change in the CTV and the range uncertainty of the proton beam. It produces a dose distribution that takes into account the internal and setup margins, virtually the same as the PTV [20,21].
The treatment plan used two beams with gantry angles of 90° and 270°, with the isocenter set in the center of the CTV. A pencil beam algorithm was used with a 2.5 × 2.5 × 2.5 mm dose grid for the proton dose calculation. Finally, for the obtained beam information, dose calculations were performed for a total of 12 different displacements of ±5 mm (3 mm on the rectal side) relative to the isocenter and ±3.5% uncertainty in the CT values and stopping-power ratio conversion to evaluate the CTV dose.

2.4.2. PS Method

The PS proton beam was irradiated from the cyclotron accelerator and then expanded to the required SOBP using beam-wobbling magnets, a lead scatterer, and ridge filters. Compensators were designed and applied to adjust the distal shape of the SOBPs according to the target locations and the direction of the beams.
The PS beams were centered on the PTV with gantry angles = 90° and 270°. Setup errors of 5 mm were assigned to the CTV, similar to the definition of the PTV. A beam-specific PTV (bs-PTV) was created and planned using a CT value, an uncertainty of ±3.5% in the stopping-power ratio conversion, and smearing margins of 6 mm [22,23]. The irradiation field was designed using multileaf collimators (MLCs) with a field margin of 10 to 12 mm, according to the shape of the bs-PTV. Dose calculations were performed using the pencil beam algorithm with a 2.5 × 2.5 × 2.5 mm dose grid. In the latter eight fractions of PS therapy, the cone-down technique was used to reduce the dose to the rectum. The aggregated dose results from the initial and boost irradiation fields are reported using the PS method.

2.4.3. VMAT

VMAT (RapidArc, Eclipse Treatment Planning System version 13, Varian Medical Systems, Palo Alto, CA, USA) is an advanced form of IMRT. VMAT uses one or more arcs that simultaneously vary the gantry rotation speed, dose rate, and leaf position of the MLC to deliver a highly conformal radiation dose to the target [24].
Two coplanar arcs with a 10 MV X-ray were used in this study. The PTV was set as a 5 mm margin from the CTV, with a margin of 3 mm to that of the posterior. This was based on the assumption that image guidance would be carried out using cone beam CT, and a smaller margin was used compared to that used in several clinical trials. Dose optimization was performed using the photon optimizer 13.7 of the Eclipse treatment planning system. The dose calculation algorithm used was AcurosXB, with a calculation grid of 2.5 × 2.5 × 2.5 mm.

2.5. Treatment Plan Comparison and Statistical Analysis

Unlike PS and VMAT, LS does not have the concept of a PTV. However, LS does involve both setup errors and beam uncertainties in its planning and evaluation process. Hence, we consider them similar, although the three treatment planning methods do not use the same evaluation set. Accordingly, in this study, the CTV was used for dose analysis of the target volume. D98, D50, D02, Dmax, and the heterogeneity index (HI) were compared as indices of the CTV. HI is calculated as follows: (D02–D98)/D50. For the rectal and bladder walls, the evaluation indices were every 10 Gy for V10 to V60 and every 5 Gy for V65 to V75, Dmean, and Dmax. All parameters above were evaluated using the Friedman test, followed by adjustment using the Bonferroni method, with p < 0.05 considered to be statistically significant. Statistical analysis was performed using SPSS version 22.0 (IBM, Armonk, NY, USA).

3. Results

3.1. Overall Results

A total of 30 patients were included in this study; risk groups as defined by the National Comprehensive Cancer Network were 5, 10, 10, and 5 patients in the low-, intermediate-, high-, and very-high-risk groups, respectively. The median age was 70.5 years. The median prostate and CTV volumes were 30.5 and 32.2 mL. Further details are summarized in Table 1. A comparison of the dose distribution between the three treatment modalities for a representative example case is shown in Figure 1.
Figure 2 shows the DVH curves for each patient and the median values in the CTV (a), rectal wall (b), and bladder wall (c), respectively, which are summarized in Table 2.
In all 30 patients that were investigated, the LS technique satisfied the dose restrictions for the CTV, rectal wall, and bladder wall. The PS technique failed to fulfill the criteria in 10 (33.3%) and 21 patients (70.0%) in the rectal wall (9 patients in V65 and V40 and 1 in V65) and bladder wall (18 patients in V65 and V40 and 3 in V65), while meeting the CTV criteria. Although all the patients satisfied the requirements for the CTV using the VMAT method, 5 patients (16.7%) failed to meet the dose constraints in the rectal wall (2 patients in V65 and V40 and 3 in V65), and 1 patient (3.3%) failed to meet the dose constraints in the bladder wall (V65).

3.2. CTV

All three treatments showed similar dose coverage of the CTV, although the overall index values in LS and PS were slightly more favorable than those in VMAT. PS was better than LS only in terms of Dmax.

3.3. Rectal Wall

Figure 3a shows the box-and-whisker plots that summarize the results obtained for the rectal wall. LS reduced the rectal wall dose in the range of V10–V70 and the Dmean with statistical significance over the other two methods. For V65, LS showed a dose decrease of 4.4% compared to PS and 2.1% compared to the VMAT cases. For V40, the corresponding values were 8.8% and 5.8%, respectively.
PS was the best among the three methods in the high-dose range (V75 and Dmax). There was no dose–volume index for which VMAT was better than LS. Comparing PS and VMAT, PS reduced the dose in the low (V10–V20) and high-dose regions (V75 and Dmax), while VMAT reduced the dose in the medium-dose region (V30–V65).

3.4. Bladder Wall

LS was the best for all indices except Dmax in the bladder wall (Figure 3b). LS showed a median drop of 9.9% and 1.3% compared to PS and VMAT in V65 of the bladder wall. For V40, the corresponding values were 12.6% and 6.1%, respectively.
As observed in the rectal wall, LS outperformed VMAT in all indicators. Only in Dmax did PS show a lower dose than LS and VMAT. VMAT yielded a lower irradiated volume in the medium- to high-dose range (V30 to V70) compared to PS.

4. Discussion

This is the first study to simultaneously compare LS, PS, and VMAT treatment plans for localized prostate cancer. The LS technique was successful in all of the patients examined, even though the rectum and bladder constraints in this study were stricter than those typically used in clinical trials [25,26]. According to this study’s findings, switching from PS proton therapy to LS for localized prostate cancer could further reduce side effects while maintaining the treatment’s effectiveness.

4.1. Rectal Dose and GI Toxicities

According to the findings of this study, the level of rectal bleeding observed after the use of the LS method is expected to be comparable to that observed after the use of the PS method and better than that following VMAT. Several studies have reported that late rectal bleeding results from an irradiated rectal volume with a high dose range (from > 60 Gy to Dmax) [27,28]. Colaco et al. analyzed 1285 patients treated with proton therapy and reported that V75 was a prognostic factor [29]. Their results showed that rectal wall V75 < 9.2% was associated with significantly less rectal bleeding of grade 2 or higher. Of the 30 patients we analyzed in this study, all patients fulfilled this V75 criterion in LS, with the highest case representing only 7.7%. The median index of LS was inferior to PS in V75 and Dmax in this study, although the difference was only slight (0.9% and 1.3 GyE).
Along with reducing the occurrence of rectal bleeding, LS proton therapy could also reduce the occurrence of other GI toxicities. The findings of several studies suggest a necessity for overall dose reduction, not only in the high-dose range but also in the low-to-medium dose range, to minimize late GI toxicities. A recent study revealed that other GI symptoms, such as fecal incontinence, changes in bowel movement frequency, rectal pain, and rectal ulceration, are associated with low-to-medium dose ranges [30]. Among these symptoms, fecal incontinence has been reported to be highly influenced by V30-V40 [31,32].
The use of a perirectal hydrogel spacer (SpaceOAR; Augmenix, Waltham, MA, USA) in conjunction with scanning proton therapy will lessen overall GI toxicity as well as rectal bleeding. SpaceOAR is a bioabsorbable hydrogel that is inserted between the rectum and prostate before radiation therapy to create a temporary anatomic separation [33]. This device reduced the incidence of rectal bleeding following IMRT for prostate cancer in a phase 3 trial [34]. Additionally, a recent study showed that using hydrogel spacers during proton therapy can reduce the incidence of rectal bleeding [35]. Combining dose reduction in the medium-to-low dosage range by means of the scanning method with dose reduction in the high-dose range through spacer placement could result in a safer dose escalation.

4.2. Bladder and Urethral Dose and GU Toxicities

Our results revealed a general dose reduction in the bladder wall using LS compared to the other two methods. However, it is currently not clear to what extent these results will improve clinical GU toxicities. To summarize the results of previous studies, late GU toxicities do not correlate as clearly with DVH parameters as late GI toxicities do [36,37]. Multiple factors might impede the explanation for the correlation between DVH parameters and late GU toxicities. Unlike late GI symptoms, GU symptoms require a longer time to develop over several years [5,6]. Even without radiation therapy, aging increases the number of patients who experience GU symptoms [38]. In addition, a remaining major problem is that late GU toxicities are symptoms caused by both an irradiated bladder and urethra, and it is essentially difficult to identify which organ is the primary contributor [37]. Herein, the impacts of irradiation on the bladder and urethra on GU toxicities are discussed individually.
It is expected that implementing the LS technique will lead to a reduction in GU toxicities through a decreased bladder dose. Multiple studies have demonstrated an association between bladder dose and GU toxicities, along with various clinical variables [37,39,40]. According to the available research, dose reduction is necessary for the entire bladder as well as the bladder triangle [41,42]. The problem, however, is that the bladder fluctuates during treatment and that the irradiated dose may differ from the planned dose [43]. Based on the evidence presented, bladder dose reduction is likely to partially alleviate GU toxicities.
For GI toxicities, dose reduction in the urethra is as important as in the bladder. Clinical trials using stereotactic body radiotherapy have revealed a relationship between urethral dose and early and late GU toxicities typified by urethral stricture [44,45]. However, compared to traditional whole prostate irradiation, a prospective clinical trial designed to reduce the urethral dose and improve GU side effects revealed worse biochemical control [46]. In addition, routine urethral dosage reduction also faces numerous technical difficulties [47]. Reducing the dose in the urethra, located approximately in the middle of the prostate, is more challenging than a partial dose reduction in the bladder. Given these data, further research is needed on the necessity and feasibility of urethral dose reduction.

4.3. Comparison of Proton Therapy and IMRT

The results of this study revealed that all dose volume indices in VMAT were inferior to LS and partially better than PS. Currently, IMRT is one of the standard radiotherapies for patients with localized prostate cancer. VMAT is an advanced form of IMRT, and its main feature is the ability to shorten the time of treatment. Furthermore, some studies have demonstrated that VMAT improves the dose distribution compared to that of IMRT [48]. Proton therapy using PS has been reported to offer favorable disease control and low late GI and GU toxicity rates in several studies, although a direct comparison of the PS method with IMRT has not been reported at the time of publication [5,6,7,8,9].
Based on our findings, it is not inconsistent to find that IMRT and proton therapy using the PS technique did not significantly differ in terms of overall GI and GU toxicities in several studies. The planning comparisons between PS and IMRT have revealed that dose reduction for OARs with proton therapy is mainly observed in the low-to-medium dose range [49,50,51]. In terms of toxicities, several trials comparing proton therapy and IMRT have reported conflicting results [52,53,54]. Vapiwala et al. recently published the results of a multicenter, retrospective study of IMRT and proton therapy using mild hypofractionation in 1850 patients at low and intermediate risk [55]. The incidence of severe late GI and GU toxicities was low and did not differ between the two groups. However, details on the specific IMRT (static or rotational) and proton therapy techniques (PS or scanning) used are not available.
Tran and colleagues conducted a comparative study evaluating intensity-modulated proton therapy, VMAT, and 4π radiotherapy in 10 patients diagnosed with prostate cancer [56]. The results of their investigation suggest that the potential of proton therapy to reduce the radiation dosage in the bladder and rectum is limited to the high-dose range. Their findings are in contrast with those of the current study, which could have been influenced by factors such as the scanning beam’s spot size and the gantry angle selected for the treatment.

4.4. Comparison of the LS Method and the PS Method

In the current study, a significant dose reduction in the rectal and bladder walls was observed with LS compared to PS, and this method is expected to reduce the risk of clinical toxicities. However, contrary to our results, the PC001-09 study reported no difference in late GU toxicities at 12 months between the scanning and PS methods [57,58]. In addition, regarding GI toxicities, the scanning method was slightly inferior to the PS at 12 months. It is difficult to directly interpret the inferiority of the scanning method based on the results of this study alone since the published results do not provide information on the patients’ backgrounds, including comorbidities and pretreatment GU symptoms. The scanning method is a novel proton irradiation method with few reports of efficacy issues and toxicity in prostate cancer. Future randomized control trials will need to confirm whether scanning with improved dose distribution reduces late GU and GI toxicities compared to IMRT and PS. In particular, long-term follow-up is necessary to evaluate late GU toxicities since the incidence of late GI toxicities reaches a plateau in the first 2–3 years after proton therapy, while the incidence of late GU toxicities tends to increase [5,6].
At many facilities, proton therapy is transitioning from the PS method to the PBS method, represented by LS. Due to the indolent nature of prostate cancer, it will take a long time to evaluate new treatments. In the future, however, it is expected that clinical reports will confirm that PBS is associated with fewer toxicities and that PBS will become the standard proton therapy method for prostate cancer. On the other hand, proton therapy has weaknesses in terms of cost and availability. VMAT, the current standard of treatment, is also expected to remain an important treatment option.

4.5. Strengths and Limitations

The strength of our research is that it is the first study to compare the three treatments for prostate cancer in a large number of patients. However, our study has several limitations. The most significant limitation of this study is that it is an in silico study and did not compare the actual late toxicities that occurred. Long-term follow-up is necessary to evaluate the late toxicities caused by radiation therapy for prostate cancer, especially GU toxicities. Therefore, a prospective trial with a planned follow-up of at least five years is desirable to compare treatment modalities. Considering this study’s results, we are currently preparing a prospective trial to compare the different clinical effectiveness of LS, PS, and VMAT in prostate cancer patients. Second, the target doses had to be compared in terms of CTV because of the different conceptions of PTV in the three irradiation methods. However, the OARs dose for the three irradiation modalities was found to be significantly different even when the minimally needed CTV dose was used. Third, our study does not compare the organs that affect sexual function in each treatment. Finally, cost and availability, which should be considered for treatment options, as well as efficacy and toxicities, were not considered in this study.

5. Conclusions

The LS method can further reduce the dose to the rectal and bladder walls while maintaining the dose to the CTV compared to the PS method and VMAT, which may result in a reduced incidence of late GI and GU toxicities.

Author Contributions

All authors contributed to the study’s conception and design. Material preparation, data collection, and analysis were performed by M.T., Y.H. and K.T. The first draft of the manuscript was written by M.T., and all authors commented on previous versions of the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards. This study was approved by the Bioethics Committee of the Sapporo Teishinkai Hospital (R030221). All study participants received written information about this study and signed consent forms to participate and for the study results to be published.

Informed Consent Statement

Informed consent was obtained from all individual participants included in the study.

Data Availability Statement

Research data are available at [https://data.mendeley.com/datasets/bbjj233tn7/draft?a=89aba735-0607-4077-8336-72c6d5b07ffa] (accessed on 26 January 2023).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Hamdy, F.C.; Donovan, J.L.; Lane, J.A.; Mason, M.; Metcalfe, C.; Holding, P.; Davis, M.; Peters, T.J.; Turner, E.L.; Martin, R.M.; et al. 10-year outcomes after monitoring, surgery, or radiotherapy for localized prostate cancer. N. Engl. J. Med. 2016, 375, 1415–1424. [Google Scholar] [CrossRef] [PubMed]
  2. Wolff, R.F.; Ryder, S.; Bossi, A.; Briganti, A.; Crook, J.; Henry, A.; Karnes, J.; Potters, L.; de Reijke, T.; Stone, N.; et al. A systematic review of randomised controlled trials of radiotherapy for localised prostate cancer. Eur. J. Cancer 2015, 51, 2345–2367. [Google Scholar] [CrossRef] [PubMed]
  3. Jacobs, B.L.; Zhang, Y.; Schroeck, F.R.; Skolarus, T.A.; Wei, J.T.; Montie, J.E.; Gilbert, S.M.; Strope, S.A.; Dunn, R.L.; Miller, D.C.; et al. Use of advanced treatment technologies among men at low risk of dying from prostate cancer. JAMA 2013, 309, 2587–2595. [Google Scholar] [CrossRef]
  4. Sheets, N.C.; Goldin, G.H.; Meyer, A.M.; Wu, Y.; Chang, Y.; Sturmer, T.; Holmes, J.A.; Reeve, B.B.; Godley, P.A.; Carpenter, W.R.; et al. Intensity-modulated radiation therapy, proton therapy, or conformal radiation therapy and morbidity and disease control in localized prostate cancer. JAMA 2012, 307, 1611–1620. [Google Scholar] [CrossRef]
  5. Takagi, M.; Demizu, Y.; Fujii, O.; Terashima, K.; Niwa, Y.; Daimon, T.; Tokumaru, S.; Fuwa, N.; Hareyama, M.; Okimoto, T. Proton therapy for localized prostate cancer: Long-term results from a single-center experience. Int. J. Radiat. Oncol. Biol. Phys. 2021, 109, 964–974. [Google Scholar] [CrossRef]
  6. Iwata, H.; Ishikawa, H.; Takagi, M.; Okimoto, T.; Murayama, S.; Akimoto, T.; Wada, H.; Arimura, T.; Sato, Y.; Araya, M.; et al. Long-term outcomes of proton therapy for prostate cancer in japan: A multi-institutional survey of the japanese radiation oncology study group. Cancer Med. 2018, 7, 677–689. [Google Scholar] [CrossRef] [PubMed]
  7. Takagi, M.; Demizu, Y.; Terashima, K.; Fujii, O.; Jin, D.; Niwa, Y.; Daimon, T.; Murakami, M.; Fuwa, N.; Okimoto, T. Long-term outcomes in patients treated with proton therapy for localized prostate cancer. Cancer Med. 2017, 6, 2234–2243. [Google Scholar] [CrossRef] [PubMed]
  8. Bryant, C.; Smith, T.L.; Henderson, R.H.; Hoppe, B.S.; Mendenhall, W.M.; Nichols, R.C.; Morris, C.G.; Williams, C.R.; Su, Z.; Li, Z.; et al. Five-year biochemical results, toxicity, and patient-reported quality of life after delivery of dose-escalated image guided proton therapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2016, 95, 422–434. [Google Scholar] [CrossRef] [PubMed]
  9. Mendenhall, N.P.; Hoppe, B.S.; Nichols, R.C.; Mendenhall, W.M.; Morris, C.G.; Li, Z.; Su, Z.; Williams, C.R.; Costa, J.; Henderson, R.H. Five-year outcomes from 3 prospective trials of image-guided proton therapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2014, 88, 596–602. [Google Scholar] [CrossRef]
  10. Smith, A.; Gillin, M.; Bues, M.; Zhu, X.R.; Suzuki, K.; Mohan, R.; Woo, S.; Lee, A.; Komaki, R.; Cox, J.; et al. The M. D. Anderson proton therapy system. Med. Phys. 2009, 36, 4068–4083. [Google Scholar] [CrossRef]
  11. Wilson, R.R. Radiological use of fast protons. Radiology 1946, 47, 487–491. [Google Scholar] [CrossRef]
  12. Slater, J.M.; Archambeau, J.O.; Miller, D.W.; Notarus, M.I.; Preston, W.; Slater, J.D. The proton treatment center at loma linda university medical center: Rationale for and description of its development. Int. J. Radiat. Oncol. Biol. Phys. 1992, 22, 383–389. [Google Scholar] [CrossRef]
  13. Kawachi, K.; Kanai, T.; Matsuzawa, H.; Inada, T. Three dimensional spot beam scanning method for proton conformation radiation therapy. Acta Radiol. Suppl. 1983, 364, 81–88. [Google Scholar]
  14. Sakurai, H.; Ishikawa, H.; Okumura, T. Proton beam therapy in japan: Current and future status. Jpn. J. Clin. Oncol. 2016, 46, 885–892. [Google Scholar] [CrossRef] [PubMed]
  15. Chu, W.; Ludewigt, B.; Renner, T. Instrumentation for treatment of cancer using proton and light-ion beams. Rev. Sci. Instrum. 1993, 64, 2055–2122. [Google Scholar] [CrossRef]
  16. Han, Y. Current status of proton therapy techniques for lung cancer. Radiat. Oncol. J. 2019, 37, 232–248. [Google Scholar] [CrossRef]
  17. Klimpki, G.; Zhang, Y.; Fattori, G.; Psoroulas, S.; Weber, D.C.; Lomax, A.; Meer, D. The impact of pencil beam scanning techniques on the effectiveness and efficiency of rescanning moving targets. Phys. Med. Biol. 2018, 63, 145006. [Google Scholar] [CrossRef] [PubMed]
  18. Schätti, A.; Meer, D.; Lomax, A.J. First experimental results of motion mitigation by continuous line scanning of protons. Phys. Med. Biol. 2014, 59, 5707–5723. [Google Scholar] [CrossRef] [PubMed]
  19. Unkelbach, J.; Chan, T.C.; Bortfeld, T. Accounting for range uncertainties in the optimization of intensity modulated proton therapy. Phys. Med. Biol. 2007, 52, 2755–2773. [Google Scholar] [CrossRef]
  20. Liu, W.; Zhang, X.; Li, Y.; Mohan, R. Robust optimization of intensity modulated proton therapy. Med. Phys. 2012, 39, 1079–1091. [Google Scholar] [CrossRef]
  21. Pflugfelder, D.; Wilkens, J.J.; Oelfke, U. Worst case optimization: A method to account for uncertainties in the optimization of intensity modulated proton therapy. Phys. Med. Biol. 2008, 53, 1689–1700. [Google Scholar] [CrossRef]
  22. Park, P.C.; Zhu, X.R.; Lee, A.K.; Sahoo, N.; Melancon, A.D.; Zhang, L.; Dong, L. A beam-specific planning target volume (ptv) design for proton therapy to account for setup and range uncertainties. Int. J. Radiat. Oncol. Biol. Phys. 2012, 82, e329–e336. [Google Scholar] [CrossRef] [PubMed]
  23. Moyers, M.F.; Miller, D.W.; Bush, D.A.; Slater, J.D. Methodologies and tools for proton beam design for lung tumors. Int. J. Radiat. Oncol. Biol. Phys. 2001, 49, 1429–1438. [Google Scholar] [CrossRef] [PubMed]
  24. Otto, K. Volumetric modulated arc therapy: Imrt in a single gantry arc. Med. Phys. 2008, 35, 310–317. [Google Scholar] [CrossRef] [PubMed]
  25. Jolnerovski, M.; Salleron, J.; Beckendorf, V.; Peiffert, D.; Baumann, A.S.; Bernier, V.; Huger, S.; Marchesi, V.; Chira, C. Intensity-modulated radiation therapy from 70gy to 80gy in prostate cancer: Six- year outcomes and predictors of late toxicity. Radiat. Oncol. 2017, 12, 99. [Google Scholar] [CrossRef] [PubMed]
  26. Dearnaley, D.; Syndikus, I.; Mossop, H.; Khoo, V.; Birtle, A.; Bloomfield, D.; Graham, J.; Kirkbride, P.; Logue, J.; Malik, Z.; et al. Conventional versus hypofractionated high-dose intensity-modulated radiotherapy for prostate cancer: 5-year outcomes of the randomised, non-inferiority, phase 3 chhip trial. Lancet Oncol. 2016, 17, 1047–1060. [Google Scholar] [CrossRef] [PubMed]
  27. Fiorino, C.; Alongi, F.; Perna, L.; Broggi, S.; Cattaneo, G.M.; Cozzarini, C.; Di Muzio, N.; Fazio, F.; Calandrino, R. Dose–volume relationships for acute bowel toxicity in patients treated with pelvic nodal irradiation for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2009, 75, 29–35. [Google Scholar] [CrossRef]
  28. Michalski, J.M.; Gay, H.; Jackson, A.; Tucker, S.L.; Deasy, J.O. Radiation dose–volume effects in radiation-induced rectal injury. Int. J. Radiat. Oncol. Biol. Phys. 2010, 76, S123–S129. [Google Scholar] [CrossRef]
  29. Colaco, R.J.; Hoppe, B.S.; Flampouri, S.; McKibben, B.T.; Henderson, R.H.; Bryant, C.; Nichols, R.C.; Mendenhall, W.M.; Li, Z.; Su, Z.; et al. Rectal toxicity after proton therapy for prostate cancer: An analysis of outcomes of prospective studies conducted at the university of florida proton therapy institute. Int. J. Radiat. Oncol. Biol. Phys. 2015, 91, 172–181. [Google Scholar] [CrossRef]
  30. Wilkins, A.; Naismith, O.; Brand, D.; Fernandez, K.; Hall, E.; Dearnaley, D.; Gulliford, S. Derivation of dose/volume constraints for the anorectum from clinician- and patient-reported outcomes in the chhip trial of radiation therapy fractionation. Int. J. Radiat. Oncol. Biol. Phys. 2020, 106, 928–938. [Google Scholar] [CrossRef]
  31. Gulliford, S.L.; Partridge, M.; Sydes, M.R.; Andreyev, J.; Dearnaley, D.P. A comparison of dose–volume constraints derived using peak and longitudinal definitions of late rectal toxicity. Radiother. Oncol. J. Eur. Soc. Ther. Radiol. Oncol. 2010, 94, 241–247. [Google Scholar] [CrossRef]
  32. Fiorino, C.; Rancati, T.; Fellin, G.; Vavassori, V.; Cagna, E.; Casanova Borca, V.; Girelli, G.; Menegotti, L.; Monti, A.F.; Tortoreto, F.; et al. Late fecal incontinence after high-dose radiotherapy for prostate cancer: Better prediction using longitudinal definitions. Int. J. Radiat. Oncol. Biol. Phys. 2012, 83, 38–45. [Google Scholar] [CrossRef] [PubMed]
  33. Hatiboglu, G.; Pinkawa, M.; Vallée, J.P.; Hadaschik, B.; Hohenfellner, M. Application technique: Placement of a prostate-rectum spacer in men undergoing prostate radiation therapy. BJU Int. 2012, 110, E647–E652. [Google Scholar] [CrossRef]
  34. Hamstra, D.A.; Mariados, N.; Sylvester, J.; Shah, D.; Karsh, L.; Hudes, R.; Beyer, D.; Kurtzman, S.; Bogart, J.; Hsi, R.A.; et al. Continued benefit to rectal separation for prostate radiation therapy: Final results of a phase iii trial. Int. J. Radiat. Oncol. Biol. Phys. 2017, 97, 976–985. [Google Scholar] [CrossRef] [PubMed]
  35. Thompson, A.B.; Hamstra, D.A. Rectal spacer usage with proton radiation therapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2020, 108, 644–648. [Google Scholar] [CrossRef] [PubMed]
  36. Viswanathan, A.N.; Yorke, E.D.; Marks, L.B.; Eifel, P.J.; Shipley, W.U. Radiation dose–volume effects of the urinary bladder. Int. J. Radiat. Oncol. Biol. Phys. 2010, 76, S116–S122. [Google Scholar] [CrossRef] [PubMed]
  37. Rancati, T.; Palorini, F.; Cozzarini, C.; Fiorino, C.; Valdagni, R. Understanding urinary toxicity after radiotherapy for prostate cancer: First steps forward. Tumori 2017, 103, 395–404. [Google Scholar] [CrossRef]
  38. Malmsten, U.G.; Molander, U.; Peeker, R.; Irwin, D.E.; Milsom, I. Urinary incontinence, overactive bladder, and other lower urinary tract symptoms: A longitudinal population-based survey in men aged 45-103 years. Eur. Urol. 2010, 58, 149–156. [Google Scholar] [CrossRef]
  39. Landoni, V.; Fiorino, C.; Cozzarini, C.; Sanguineti, G.; Valdagni, R.; Rancati, T. Predicting toxicity in radiotherapy for prostate cancer. Phys. Med. 2016, 32, 521–532. [Google Scholar] [CrossRef]
  40. Zelefsky, M.J.; Kollmeier, M.; Cox, B.; Fidaleo, A.; Sperling, D.; Pei, X.; Carver, B.; Coleman, J.; Lovelock, M.; Hunt, M. Improved clinical outcomes with high-dose image guided radiotherapy compared with non-igrt for the treatment of clinically localized prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2012, 84, 125–129. [Google Scholar] [CrossRef]
  41. Heemsbergen, W.D.; Al-Mamgani, A.; Witte, M.G.; van Herk, M.; Pos, F.J.; Lebesque, J.V. Urinary obstruction in prostate cancer patients from the dutch trial (68 gy vs. 78 gy): Relationships with local dose, acute effects, and baseline characteristics. Int. J. Radiat. Oncol. Biol. Phys. 2010, 78, 19–25. [Google Scholar] [CrossRef] [PubMed]
  42. Pederson, A.W.; Fricano, J.; Correa, D.; Pelizzari, C.A.; Liauw, S.L. Late toxicity after intensity-modulated radiation therapy for localized prostate cancer: An exploration of dose–volume histogram parameters to limit genitourinary and gastrointestinal toxicity. Int. J. Radiat. Oncol. Biol. Phys. 2012, 82, 235–241. [Google Scholar] [CrossRef] [PubMed]
  43. Muren, L.P.; Smaaland, R.; Dahl, O. Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer. Radiother. Oncol. J. Eur. Soc. Ther. Radiol. Oncol. 2003, 69, 291–304. [Google Scholar] [CrossRef] [PubMed]
  44. Leeman, J.E.; Chen, Y.H.; Catalano, P.; Bredfeldt, J.; King, M.; Mouw, K.W.; D’Amico, A.V.; Orio, P.; Nguyen, P.L.; Martin, N. Radiation dose to the intraprostatic urethra correlates strongly with urinary toxicity after prostate stereotactic body radiation therapy: A combined analysis of 23 prospective clinical trials. Int. J. Radiat. Oncol. Biol. 2022, 112, 75–82. [Google Scholar] [CrossRef]
  45. Magli, A.; Farneti, A.; Faiella, A.; Ferriero, M.; Landoni, V.; Giannarelli, D.; Moretti, E.; de Paula, U.; Gomellini, S.; Sanguineti, G. Toxicity at 1 year after stereotactic body radiation therapy in 3 fractions for localized prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2021, 111, 93–100. [Google Scholar] [CrossRef] [PubMed]
  46. Vainshtein, J.; Abu-Isa, E.; Olson, K.B.; Ray, M.E.; Sandler, H.M.; Normolle, D.; Litzenberg, D.W.; Masi, K.; Pan, C.; Hamstra, D.A. Randomized phase ii trial of urethral sparing intensity modulated radiation therapy in low-risk prostate cancer: Implications for focal therapy. Radiat. Oncol. 2012, 7, 82. [Google Scholar] [CrossRef] [PubMed]
  47. Zilli, T.; Achard, V.; Guevelou, J.L. Intraprostatic urethra: The new kid on the block for prostate cancer radiation therapy? Int. J. Radiat. Oncol. Biol. Phys. 2022, 113, 92–95. [Google Scholar] [CrossRef]
  48. Wolff, D.; Stieler, F.; Welzel, G.; Lorenz, F.; Abo-Madyan, Y.; Mai, S.; Herskind, C.; Polednik, M.; Steil, V.; Wenz, F.; et al. Volumetric modulated arc therapy (vmat) vs. Serial tomotherapy, step-and-shoot imrt and 3d-conformal rt for treatment of prostate cancer. Radiother. Oncol. 2009, 93, 226–233. [Google Scholar] [CrossRef]
  49. Trofimov, A.; Nguyen, P.L.; Coen, J.J.; Doppke, K.P.; Schneider, R.J.; Adams, J.A.; Bortfeld, T.R.; Zietman, A.L.; Delaney, T.F.; Shipley, W.U. Radiotherapy treatment of early-stage prostate cancer with imrt and protons: A treatment planning comparison. Int. J. Radiat. Oncol. Biol. Phys. 2007, 69, 444–453. [Google Scholar] [CrossRef]
  50. Vargas, C.; Fryer, A.; Mahajan, C.; Indelicato, D.; Horne, D.; Chellini, A.; McKenzie, C.; Lawlor, P.; Henderson, R.; Li, Z.; et al. dose–volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer. Int. J. Radiat. Oncol. Biol. Phys. 2008, 70, 744–751. [Google Scholar] [CrossRef]
  51. Mock, U.; Bogner, J.; Georg, D.; Auberger, T.; Potter, R. Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy. Strahlenther. Onkol. Organ Dtsch. Rontgenges. 2005, 181, 448–455. [Google Scholar] [CrossRef]
  52. Gray, P.J.; Paly, J.J.; Yeap, B.Y.; Sanda, M.G.; Sandler, H.M.; Michalski, J.M.; Talcott, J.A.; Coen, J.J.; Hamstra, D.A.; Shipley, W.U.; et al. Patient-reported outcomes after 3-dimensional conformal, intensity-modulated, or proton beam radiotherapy for localized prostate cancer. Cancer 2013, 119, 1729–1735. [Google Scholar] [CrossRef] [PubMed]
  53. Yu, J.B.; Soulos, P.R.; Herrin, J.; Cramer, L.D.; Potosky, A.L.; Roberts, K.B.; Gross, C.P. Proton versus intensity-modulated radiotherapy for prostate cancer: Patterns of care and early toxicity. J. Natl. Cancer Inst. 2013, 105, 25–32. [Google Scholar] [CrossRef]
  54. Fang, P.; Mick, R.; Deville, C.; Both, S.; Bekelman, J.E.; Christodouleas, J.P.; Guzzo, T.J.; Tochner, Z.; Hahn, S.M.; Vapiwala, N. A case-matched study of toxicity outcomes after proton therapy and intensity-modulated radiation therapy for prostate cancer. Cancer 2015, 121, 1118–1127. [Google Scholar] [CrossRef] [PubMed]
  55. Vapiwala, N.; Wong, J.K.; Handorf, E.; Paly, J.; Grewal, A.; Tendulkar, R.; Godfrey, D.; Carpenter, D.; Mendenhall, N.P.; Henderson, R.H.; et al. A pooled toxicity analysis of moderately hypofractionated proton beam therapy and intensity modulated radiation therapy in early-stage prostate cancer patients. Int. J. Radiat. Oncol. Biol. Phys. 2021, 110, 1082–1089. [Google Scholar] [CrossRef] [PubMed]
  56. Tran, A.; Zhang, J.; Woods, K.; Yu, V.; Nguyen, D.; Gustafson, G.; Rosen, L.; Sheng, K. Treatment planning comparison of impt, vmat and 4π radiotherapy for prostate cases. Radiat. Oncol. 2017, 12, 10. [Google Scholar] [CrossRef] [PubMed]
  57. Mishra, M.V.; Khairnar, R.; Bentzen, S.M.; Larson, G.; Tsai, H.; Sinesi, C.; Vargas, C.; Laramore, G.; Rossi, C.; Rosen, L.; et al. Patient reported outcomes following proton pencil beam scanning vs. Passive scatter/uniform scanning for localized prostate cancer: Secondary analysis of pcg 001-09. Clin. Transl. Radiat. Oncol. 2020, 22, 50–54. [Google Scholar] [CrossRef]
  58. Mishra, M.V.; Khairnar, R.; Bentzen, S.M.; Larson, G.; Tsai, H.; Sinesi, C.; Vargas, C.; Laramore, G.; Rossi, C.; Rosen, L.; et al. Proton beam therapy delivered using pencil beam scanning vs. Passive scattering/uniform scanning for localized prostate cancer: Comparative toxicity analysis of pcg 001-09. Clin. Transl. Radiat. Oncol. 2019, 19, 80–86. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Isodose color wash images of a typical patient planned using line scanning (LS) (a), passive scattering (PS) (b), and volumetric modulated arc therapy (VMAT) (c). Seventy-six-year-old patient with favorable intermediate-risk prostate cancer (cT2a, GS = 3 + 4, initial PSA = 9.82 ng/mL). Prostate volume = 50.5 mL.
Figure 1. Isodose color wash images of a typical patient planned using line scanning (LS) (a), passive scattering (PS) (b), and volumetric modulated arc therapy (VMAT) (c). Seventy-six-year-old patient with favorable intermediate-risk prostate cancer (cT2a, GS = 3 + 4, initial PSA = 9.82 ng/mL). Prostate volume = 50.5 mL.
Cancers 16 00403 g001
Figure 2. Dose–volume histogram of all patients for the CTV (a), rectal wall (b), and bladder wall (c).
Figure 2. Dose–volume histogram of all patients for the CTV (a), rectal wall (b), and bladder wall (c).
Cancers 16 00403 g002
Figure 3. Box-and-whisker plots of dose–volume metrics of the rectal wall (a) and the bladder wall (b).
Figure 3. Box-and-whisker plots of dose–volume metrics of the rectal wall (a) and the bladder wall (b).
Cancers 16 00403 g003
Table 1. Patient characteristics.
Table 1. Patient characteristics.
VariableLevelN%
Number 30100
T classificationT1c1446.7
T2a/b/c5/2/516.7/6.7/16.7
T3a/b3/110/3.3
Gleason score6620
3 + 4723.3
4 + 3516.7
8620
9413.3
1026.7
NCCN risk groupLow516.7
Intermediate1033.3
High1033.3
Very High516.7
ADTYes1550
No1550
Variable MedianRange
Age (year)70.559–86
iPSA (ng/mL)8.34.1–116.1
Positive core (%)255.3–100
ADT period (month)304–112
Prostate volume (cm3)30.515.6–94.6
CTV volume (cm3)32.217.8–117.5
Rectal wall volume (cm3)21.416.1–31.0
Bladder wall volume (cm3)38.824.8–62.6
Abbreviations: NCCN, National Comprehensive Cancer Network; ADT, androgen deprivation therapy; PSA, prostate-specific antigen; CTV, clinical target volume.
Table 2. Comparison of the dosimetric parameters of the CTV, rectal wall, and bladder wall for the LS, PS, and VMAT plans.
Table 2. Comparison of the dosimetric parameters of the CTV, rectal wall, and bladder wall for the LS, PS, and VMAT plans.
StructureDose MetricLSPSVMATp
CTVD98
{Gy (RBE), median (range)}
74.9
(73.9–75.3)
75.0
(73.3–76.0)
74.2
(73.0–77.1)
(a) 1.000
(b) <0.001
(c) <0.001
D50
{Gy (RBE), median (range)}
76.0
(75.9–76.0)
76.0
(75.3–77.1)
75.9
(75.4–76.5)
0.393
D02
{Gy (RBE), median (range)}
77.3
(76.6–78.5)
77.1
(76.4–79.3)
77.8
(76.5–78.7)
(a) 1.000
(b) 0.009
(c) 0.014
Dmax
{Gy (RBE), median (range)}
79.3
(77.5–82.0)
77.7
(76.7–80.6)
79.5
(77.8–81.0)
(a) <0.001
(b) 1.000
(c) <0.001
Heterogeneity index
{median (range)}
0.029
(0.018–0.049)
0.028
(0.019–0.048)
0.072
(0.047–0.097)
(a) 0.905
(b) <0.001
(c) <0.001
Rectal wallV10
{%, median (range)}
37.1
(23.2–46.3)
52.0
(31.7–73.5)
70.1
(63.9–87.2)
(a) <0.001
(b) <0.001
(c) 0.060
V20
{%, median (range)}
29.5
(18.6–36.3)
41.5
(26.2–60.8)
49.3
(40.3–80.8)
(a) <0.001
(b) <0.001
(c) 0.014
V30
{%, median (range)}
24.4
(15.5–30.5)
35.5
(22.3–50.7)
35.3
(24.2–66.4)
(a) <0.001
(b) <0.001
(c) 1.000
V40
{%, median (range)}
20.4
(13.0–26.1)
29.2
(18.6–44.1)
26.2
(16.2–51.9)
(a) <0.001
(b) <0.001
(c) 0.014
V50
{%, median (range)}
16.9
(10.6–22.0)
24.3
(14.6–37.4)
20.2
(9.5–41.6)
(a) <0.001
(b) <0.001
(c) 0.001
V60
{%, median (range)}
13.1
(8.1–17.8)
18.4
(10.6–29.0)
15.1
(6.1–35.4)
(a) <0.001
(b) <0.001
(c) <0.001
V65
{%, median (range)}
10.6
(6.5–15.5)
15.0
(8.0–25.4)
12.7
(4.9–32.2)
(a) <0.001
(b) 0.085
(c) 0.002
V70
{%, median (range)}
7.9
(4.1–12.5)
10.1
(4.2–21.2)
10.1
(3.6–28.5)
(a) 0.014
(b) <0.001
(c) 0.590
V75
{%, median (range)}
1.7
(0.2–7.7)
0.8
(0–12.2)
3.4
(0.5–16.0)
(a) 0.006
(b) 0.736
(c) <0.001
Dmax
{Gy (RBE), median (range)}
77.2
(75.5–79.2)
75.9
(74.3–78.0)
77.8
(76.8–79.5)
(a) 0.002
(b) 0.072
(c) <0.001
Dmean
{Gy (RBE), median (range)}
17.6
(11.2–22.2)
24.4
(15.5–34.1)
27.5
(21.9–44.1)
(a) <0.001
(b) <0.001
(c) 0.014
Bladder wallV10
{%, median (range)}
40.8
(24.5–57.0)
54.4
(35.3–73.4)
60.8
(41.6–84.9)
(a) <0.001
(b) <0.001
(c) 0.060
V20
{%, median (range)}
34.7
(20.5–47.2)
47.5
(31.9–64.7)
50.5
(35.1–66.5)
(a) <0.001
(b) <0.001
(c) 0.590
V30
{%, median (range)}
30.6
(17.7–42.5)
43.0
(29.2–58.2)
42.0
(27.0–52.4)
(a) <0.001
(b) <0.001
(c) 0.117
V40
{%, median (range)}
26.7
(15.3–36.7)
39.3
(26.7–52.3)
32.8
(20.7–41.3)
(a) <0.001
(b) <0.001
(c) 0.001
V50
{%, median (range)}
23.5
(13.1–32.4)
35.3
(23.9–46.8)
26.0
(16.5–35.3)
(a) <0.001
(b) <0.001
(c) 0.001
V60
{%, median (range)}
20.2
(10.8–28.2)
30.8
(20.9–40.8)
21.7
(13.5–30.1)
(a) <0.001
(b) <0.001
(c) 0.001
V65
{%, median (range)}
18.4
(9.5–24.8)
28.3
(18.9–38.0)
19.7
(12.2–27.4)
(a) 0.001
(b) <0.001
(c) 0.001
V70
{%, median (range)}
15.9
(8.0–20.3)
24.0
(15.7–33.8)
17.4
(10.8–24.4)
(a) 0.001
(b) <0.001
(c) 0.001
V75
{%, median (range)}
9.3
(0.1–14.0)
11.6
(2.1–26.4)
12.1
(4.7–16.6)
(a) <0.001
(b) <0.001
(c) 1.000
Dmax
{Gy (RBE), median (range)}
78.1
(76.5–79.4)
76.8
(75.9–78.8)
79.0
(77.4–79.6)
(a) 0.014
(b) <0.001
(c) 0.004
Dmean
{Gy (RBE), median (range)}
21.8
(12.8–29.2)
31.0
(20.7–41.0)
30.0
(20.0–37.6)
(a) <0.001
(b) <0.001
(c) 0.590
Abbreviations: CTV, clinical target volume; LS, line scanning; PS, passive scattering; VMAT, volumetric modulated arc therapy; Dx, dose received by x% of the organ volume; Dmax, maximum dose; Vx, the relative volume of the organ that received at least x Gy or Gy (RBE); Dmean, mean dose; RBE, relative biological effectiveness. (a) Comparison between LS and PS; (b) comparison between LS and VMAT; (c) comparison between PS and VMAT.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Takagi, M.; Hasegawa, Y.; Tateoka, K.; Takada, Y.; Hareyama, M. Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer. Cancers 2024, 16, 403. https://doi.org/10.3390/cancers16020403

AMA Style

Takagi M, Hasegawa Y, Tateoka K, Takada Y, Hareyama M. Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer. Cancers. 2024; 16(2):403. https://doi.org/10.3390/cancers16020403

Chicago/Turabian Style

Takagi, Masaru, Yasuhiro Hasegawa, Kunihiko Tateoka, Yu Takada, and Masato Hareyama. 2024. "Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer" Cancers 16, no. 2: 403. https://doi.org/10.3390/cancers16020403

APA Style

Takagi, M., Hasegawa, Y., Tateoka, K., Takada, Y., & Hareyama, M. (2024). Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer. Cancers, 16(2), 403. https://doi.org/10.3390/cancers16020403

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop