Next Article in Journal
Dual Semi-Interpenetrating Networks of Water-Soluble Macromolecules and Supramolecular Polymer-like Chains: The Role of Component Interactions
Next Article in Special Issue
Experimental Study on Rats with Critical-Size Bone Defects Comparing Effects of Autologous Bone Graft, Equine Bone Substitute Bio-Gen® Alone or in Association with Platelet-Rich Fibrin (PRF)
Previous Article in Journal
Brucine Sulfate, a Novel Bacteriostatic Agent in 3D Printed Bone Scaffold Systems
Previous Article in Special Issue
The Impacts of the Sterilization Method and the Electrospinning Conditions of Nanofibrous Biodegradable Layers on Their Degradation and Hemocompatibility Behavior
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Researching on the Effect of Input Parameters on the Quality and Manufacturability of 3D-Printed Cellular Samples from Nylon 12 CF in Synergy with Testing Their Behavior in Bending

1
Faculty of Manufacturing Technologies with a Seat in Presov, Technical University in Kosice, 080 01 Presov, Slovakia
2
Faculty of Technology, Tomas Bata University in Zlin, Nam. T.G. Masaryka 275, 760 01 Zlin, Czech Republic
3
Faculty of Engineering Management, Poznan University of Technology, J. Rychlewskiego 2, 60-965 Poznań, Poland
*
Authors to whom correspondence should be addressed.
Polymers 2024, 16(10), 1429; https://doi.org/10.3390/polym16101429
Submission received: 19 April 2024 / Revised: 12 May 2024 / Accepted: 13 May 2024 / Published: 17 May 2024
(This article belongs to the Special Issue Polymer-Based Biomaterials for Tissue Engineering Applications)

Abstract

:
The study of cellular structures and their properties represents big potential for their future applications in real practice. The article aims to study the effect of input parameters on the quality and manufacturability of cellular samples 3D-printed from Nylon 12 CF in synergy with testing their bending behavior. Three types of structures (Schwarz Diamond, Shoen Gyroid, and Schwarz Primitive) were selected for investigation that were made via the fused deposition modeling technique. As part of the research focused on the settings of input parameters in terms of the quality and manufacturability of the samples, input parameters such as volume fraction, temperature of the working space, filament feeding method and positioning of the sample on the printing pad were specified for the combination of the used material and 3D printer. During the experimental investigation of the bending properties of the samples, a three-point bending test was performed. The dependences of force on deflection were mathematically described and the amount of absorbed energy and ductility were evaluated. The results show that among the investigated structures, the Schwarz Diamond structure appears to be the most suitable for bending stress applications.

1. Introduction

The development and application of cellular structures have spread across many industries in recent years. This is because of the extraordinary properties they have. The production of such structures with regularly distributing cells and deterministically specified geometry was not possible using conventional manufacturing methods such as turning, milling, drilling and the like. This was the main reason for the low use of cellular structures in industrial components as a whole in the past. It was only after the introduction of additive technologies that it became possible to produce complex shapes such as cellular structures. In the case of plastics, currently, the most used production methods within additive technologies include the fused deposition modeling (hereinafter FDM) technique, and in the case of metals they include direct metal laser sintering (DMLS) [1,2].
Since the final quality of the part is influenced by many parameters, a very important part of the process of producing bodies with a porous structure of the required quality is the preparatory phase, which consists of several stages. These parameters can include not only the topological characteristics of the structure (basic cell geometry, basic cell distribution and volume fraction) but also the material characteristics and technological conditions of 3D printing (layer thickness, nozzle diameter, printing speed, substrate, workspace temperatures, 3D printing strategy, etc.). All of this subsequently affects the properties of the manufactured components and their service life when they operate in technical practice. The quality of the selected components consequently affects not only their mechanical properties, and thus their operability, but also the safety of the entire device into which the components are to be implemented [3,4,5]. Therefore, the investigation of the combination of parameters used in the production process is an important aspect of research when studying their mechanical properties.

2. State of the Art

Cellular structures can be found in nature all around us. Due to their properties such as their ability to reduce weight while maintaining strength or absorbing energy and transferring heat, their use is ranges across several engineering fields (automotive, mechanical engineering, aeronautics, medicine, etc.). A cellular structure can be considered a medium that consists of a solid and a gas phase. The latter consists of an interconnected network of rigid struts or plates that form the edge0s and surfaces of the cells [6,7,8,9].
The classification of cellular structures can be divided into several subgroups. Initially, in additive manufacturing, this classification concerns the selection of the appropriate unit cell. The basic cell is selected based on what the model or proposed test sample is used for. As such, cellular structures are divided into two main categories: stochastic and non-stochastic structures. The detailed distinctions can be seen in Figure 1 [10].
Many researchers in the world have worked on the issue in the past, but there are also a number of research teams working on the issue today. In the past, even before researchers tested porous structures, they mainly tested honeycomb structures, which was also addressed, for example, by Tohid Ghanbari-Ghazijahani. The research pointed out the differences between two materials, namely wood and polylactic acid (hereafter PLA), which at the time were considered materials with high potential for use in several industries. In the research, several beams made of these materials were used with different volumes and distributions inside the investigated specimens. These were subsequently examined and tested until they were fully deformed or broken. Ultimately, these results proved that plastics such as PLA have a higher strength compared with wooden webs and results were obtained that were promising for the further pursuit of the subject in the future [11].
Another who has worked on the subject is Flaviana Calignano, who describes the actual mechanical properties of parts made from Nylon filaments that are reinforced with carbon fiber. In the results of that research, differences in values were seen that did not match the material data sheets from different material suppliers. The hardness and strength of the specimen printed from Nylon material with a 20% carbon fibere content differed due to several factors such as the printing direction, and percentage of filler, while the flexibility was mainly affected by the printing direction [12].
Vuong Nguyen-Van’s research team looked at the reinforcement of concrete beams in 2021 in their paper “Performance of concrete beam reinforced with 3D printed Bioinspired primitive scaffold subjected to three-point bending”. Since most concrete beams are reinforced with steel bars, his team decided to replace the steel bars with a concrete TPMS structure and test its flexural strength. The structure they decided to use was Primitive. In their research, three concrete beams of the same size (including unreinforced and reinforced with single- and double-layer thin-walled forms, respectively) were tested. These were made specifically for the three-point bending test only and to compare them with each other. The results of the research showed significantly improved flexural properties. When the beam was reinforced with TPMS of the Primitive structure, its flexural strength improved by 35% for the single-layer reinforcement and 125% for the double-layer reinforcement. Moreover, the research also indicated that concrete beams reinforced with a TPMS structure exhibit smooth softening in bending and show increased ductility [13].
The research on energy absorption and the mechanical properties exhibited by specimens made from TPMS structures are elaborated upon in the article by Shaun Ormiston. Specifically, this study dealt with the fabrication of composite lattice structures reinforced with a second (secondary) material. The lattice structures were modeled into cubic, cylindrical, rod, and dog-bone geometries while the volume fraction inside the specimen was varied by 25%, 50% and 75%, respectively. The structures were extruded from Nylon, which contains carbon fibers, and reinforced with glass fiber. The results showed, in this case, that the glass-fiber-reinforced structures with a reduction in the amount of material to a total of 25% had similar or better properties compared with structures with a 75% volume of the material without the addition of glass fiber reinforcement [14].
The research by Ibrahim M. Alarifi investigated the effects of changing the raster orientation (0°, 45° and 90°) using a 3D printer. Two materials were used in the research, namely Carbon Fiber Nylon (hereafter referred to as Nylon CF) and Glass Fiber Nylon (hereafter referred to as Nylon GF), the samples of which were then subjected to a three-point bending test. As the research showed in the initial results, the highest stiffness was found for the Nylon GF samples, which were tested at room temperature, whereas on the other hand, the Nylon CF samples were found to have higher elasticity and lower flexural strength than the former [15].
Cui et al. studied the effect of 3D printing process parameters and their optimization for improving the mechanical properties of a fabricated cellular structure made of fiber-reinforced PLA composite material and Kevlar filament. They investigated the effect of process parameters in 3D printing and tested the fabricated models in three-point bending. The three-point bending tests showed the relationship between process parameters and mechanical properties. They showed higher flexural strength when using Kevlar filament [16].
Myers et al. dealt with the optimization of process parameters in the fabrication of Schoen Gyroid and Schwarz Primitive cellular structures from PLA material. Analyzing the geometrical deviations of the fabricated physical models with respect to the nominal ones, they pointed out the significant influence of flow rate and layer height on the accuracy of the models. They also pointed out the significant effect of layer height and printing speed on the fabrication time [17].
Tao et al. studied the optimization of 3D models of cellular structures made of PLA composite material with wood and flour admixtures. The study highlighted the differences between the nominal model used for FEA analysis and the actual fabricated physical model. They pointed out the formation of voids within the printed model and their significant effect on the mechanical properties, and modified the 3D model to correspond to the actual compression test results against the FEA analysis [18].
The improvement in the mechanical properties of TPMS porous structures was investigated by Zhang et al. They proposed the use of adaptive thickness to reduce anisotropy [19]. Zhu et al. designed, fabricated and mechanically tested TPMS cellular structures to optimize their mechanical properties. They showed an improvement in the mechanical properties of the thickness-optimized samples [20]. Yu et al. studied the fabrication and mechanical property testing of TPMS cellular structures fabricated using additive technologies [21].
Abueidda et al. examined the mechanical properties of Gyroid cellular structures. They used FEA analysis and the Arruda–Boyce finite deformation elasto-viscoplastic model, which they compared with real testing conditions. The FEA analysis corresponded with the experimental results and indicated suitable mechanical properties compared with those of Neovius and Primitive [22].
As technologies develop very quickly, while at the same time new materials have appeared, the possibility to incorporate cellular structures not only in industrial components but also in devices of daily use is becoming an increasingly likely reality. It is therefore very important for designers to know their properties and behavior under different types of loads. The presented research aims to determine the bending properties of samples with three selected types of cellular structures (Schwarz Dimond, Schoen Gyroid and Schwarz Primitive) made of Nylon 12 CF, pointing out that the input parameters can affect not only the quality of the product but also its mechanical and other properties. Since there are many 3D printers and materials available on the market today that can be combined across a range of applications, the article offers insight into several problems that have to be solved in the 3D printing process before the actual production of final samples is achieved for experimental bending tests.
Based on the state of the art, researchers have recognized the value of porous structures that can be implemented in many applications. However, to the best of the authors’ knowledge, none of the available studies has yet investigated the behavior of selected cellular structures made of carbon fiber-reinforced Nylon under bending loads while solving problems in setting the input parameters for the available 3D printer. This represents an opportunity for contributions to the field and novel research with the potential for subsequent possibilities to implement this know-how and experience in simulations of the production process, as well as into numerical analyses of the behavior of lightweight components.

3. Materials and Methods

3.1. Characteristics of the Selected TPMS Structures

For a basic investigation of the influence of process parameters on the fabrication of Nylon Carbon Fiber cellular structures and the specification of their bending properties, Schwarz Diamond, Schwarz Primitive (also called Schwarz P) and Schoen Gyroid structures, which belong to the group of so-called triply periodic minimal surfaces (TPMSs), were chosen in the present research. These are surfaces in three-dimensional space that minimize the surface area for a given bounding curve. At the same time, they are triple-periodic, i.e., they repeat in three independent directions, and this periodicity gives them crystallographic symmetry. They are characterized, for example, by having a zero-mean curvature at each point. This means that they are locally flat and have no sharp edges [23,24,25].
The selection of the type of samples was related to extensive research on the behavior of cellular structures that has been ongoing at the authors’ workplace for several years. The authors have dealt with the production of cellular samples produced from both metal materials (the samples were made of aluminum alloy AlSi10Mg or Inconel 718 using DMLS technology) and plastics (the samples were made of ABS and PLA using FFF technology). Concerning cell topology, the results showed that the way cells are distributed in the test body (radial or orthogonal) does not have as significant an effect on its mechanical properties as the type of structure and wall thickness (or cross-section of the strut) when maintaining the same volume fraction. Furthermore, the research showed that sharp transitions between individual struts in lattice structures (mutual position at a certain angle) act as notches and reduce their mechanical properties, in contrast to structures of triply periodic minimal surfaces (TPMSs), in which the transition between the walls in their spatial architecture is continuous and smooth. The results of already performed experimental tests on tension and compression, comparing the properties of the Schwarz Diamond, Schoen Gyroid and Schwarz Primitive structures, highlighted the dominance of the Schwarz Diamond structure, so in the presented research, the authors tried to determine the behavior of the structures under bending loads and verify whether the Schwarz Diamond structure would again be the best in terms of bending. This method of stressing is very common in practice, whether in the civil engineering industry for the load-bearing constructions of buildings or for the static stressing of shafts in mechanical engineering, but it can also be found in various frame constructions (e.g., conveyors and gantry cranes), such as in the aviation industry.
Figure 2 shows the structures chosen for this research along with the geometries of their basic cell. The Schwarz Diamond structure (Figure 2a) has simple two-dimensional sixfold symmetry, which means that each vertex of this surface is connected to six vertices in its surroundings, and this structured is formed by a lattice with simple symmetric surfaces [26,27,28].
In contrast to the Schwarz Diamond structure, the Schwarz Primitive (Figure 2b) structure differs in that each vertex of the surface is connected to five vertices in its surroundings. Geometrically, it is a structure that is formed by a grid where each face is symmetrical to the others [29,30].
The Schoen Gyroid (Figure 2c) is a structure that is characterized by triple-period and minimum-area surfaces. The structure offers high planar distributivity and an open post-surface morphology that can be exploited for efficient interaction with other substances or the environment [31].

3.2. Material of the Samples

The specimens for flexural testing were made from Nylon 12 Carbon Fiber, (MakerBot, New York, NY, USA), hereafter referred to as Nylon 12 CF, which is created by blending Nylon 12 and short carbon fibers. It has high strength, resistance to wear, chemicals and moisture. The carbon fibers in this case give the material extra strength and stiffness. Thanks to its durability and strength, it is used in several sectors such as aviation (aircraft components such as wings, fuselage and landing gear), automotive (parts such as bumpers, fenders and bodywork), mechanical engineering (bearings, gears or various types of housing) and sports (skis, snowboards and tennis racquets). Nylon 12 CF material is characterized by high abrasive properties, and therefore a hardened steel or ruby nozzle is recommended for 3D printing. The advantages of the material include its high strength, durability and its lightness, making it resistant to chemicals. The disadvantages are its lower ductility and temperature resistance [32,33].

3.3. Production of Samples

Virtual 3D models of selected TPMS structures were created using PTC Creo Parametric 10 software, and they were exported into an STL file for further processing. The MarkerBot Method X printer (MakerBot, New York, NY, USA), available in the authors’ workplace, was employed with MarkerBot Cloud software 3.10.1 for the specimens’ fabrication.
For the investigation of the bending properties, the samples (shown in Figure 3), measuring 20 × 20 × 250 mm with selected TPMS structures, were produced with sizes of a basic cell of 10 × 10 × 10 mm and a volume fraction of Vf = 30%, which was specified based on Equation (1) [34]:
V f = V R   V C 100   ( % )
where VR is the material volume used for structure production, and VC is a total volume of the sample.
The fabrication of specimens for testing the flexural loading properties of the structures was preceded by extensive research into the input parameters (described in more detail in Section 3), which had a significant influence on the final quality of the experimental specimens. For these purposes, samples measuring 20 × 20 × 20 mm were produced while maintaining the same cell size of 10 × 10 × 10 mm, which was intended for the final samples for bending.

3.4. Experimental Testing of Specimens under Bending Loads

The flexural loading behavior of the porous specimens was tested in accordance with the ISO 178:2019 standard [35] on a Zwick 1456 (Ulm, Germany) testing machine (Figure 4a) at a temperature of 20 °C and with humidity at 50%. The supporting span was l = 200 mm, and the pressure thumb had a radius of 10 mm. The specimen set up is shown in Figure 4b.
Based on the measured data, the Young´s modulus, amount of absorbed energy and the ductility indices were evaluated.

4. Effect of Input Parameters on the Quality and Producibility of the Specimens

To implement structures into components that work in real practice, it is first of all necessary that the structures be produced repeatedly with good quality, and then it is necessary to know their properties and behavior in real conditions. Only by setting and observing the correct parameters and conditions will it be possible to ensure the reliability and safety of the operation of such a lightweight component. Testing low-quality samples with a lot of defects and without the required characteristics of shape and accuracy would therefore be meaningless. In the presented research, the authors tried to point out, in a simplified and shortened way, the importance of all basic aspects affecting the implementation of shape-complex cellular structures into lightweight components, which include the properties of the basic material, the conditions of sample production and the determination of load resistance characteristics.
During the first attempts to produce experimental samples to test their bending behavior, several problems were encountered concerning their manufacturability and their low quality. It was therefore necessary to carry out extensive preliminary research, the goal of which was to find the causes of sample production failures and to determine the influence of input parameters on their quality.
Possible reasons for failure were identified: insufficient quality and properties of the input material—filament (mechanical properties and humidity); the basic characteristics of the sample topology (the minimum volume fraction and need for supports during 3D printing); the influence of 3D printing conditions (the temperature of the working environment, method of material feeding, heat treatment process and positioning of samples in the workspace of the 3D printer). The influence of all mentioned parameters was gradually investigated, and, if necessary, the primary set values/methods were adjusted to ensure that the final samples were of sufficient quality for bending testing.
To save material, reduced specimens, measuring 20 × 20 × 20 mm were produced for this purpose, but with the same cell size of 10 × 10 × 10 mm, as was intended for the final experimental specimens stressed under bending.

4.1. Verification of Filament Properties

In the first step of identifying the causes of the poor quality of the samples and the failure of their production (when production could not be completed), the properties of the material Nylon 12 CF (which was delivered to the authors’ workplace in the form of a filament with a diameter of ϕ1.75 mm in the state of winding on spools and vacuum-packed with silicate inside) were verified, with the manufacturer declaring that it is a dried material. The properties of Nylon 12 CF stated in the material sheet provided by the producer are listed in Table 1.
Nylon 12 CF is characterized by high susceptibility to moisture; therefore, it was necessary to check that the moisture content of the material does not reach a value that would invalidate results after measurement or that would impair the quality of the printed product. Moist filament can cause this when exposed to the temperatures used in 3D printing; moisture in the filament will expand and eventually volatilize. This greatly disrupts the normal extrusion pattern of 3D printing and will likely result in quality problems in the final print. As a result, the layers are printed incompletely, with defects ranging from small spots in the layers to layers that have entire gaps or holes in them [38,39]. One indication that this is due to moisture in the filament is that the effect persists throughout the printing process, creating an uneven surface, which occurred in the case of the research presented.
The moisture content of the material was investigated using Halogen HR83 (Mettler Toledo, Columbus, OH, USA), shown in Figure 5, which works on the principle of thermogravimetry.
The material was chopped into small pieces and placed in a weighing pan, which was then placed in the drying chamber of the analyzer. The balance accurately measured the weight of the sample before drying, and then the material was dried using a halogen heater included in the instrument. During drying, the sample was weighed every 30 s. Once the sample weight was stable, the analyzer calculated the moisture content, resulting in a value for the moisture content of the sample representing a percentage of the wet weight and indicated with a negative sign [40].
The temperature and measurement times were set to the prescribed values for drying Nylon 12 CF material, namely 110 °C and 5 min, respectively. The weight of the material that was placed in the weighing pan was 1.044 g, and after drying, the weight of the material was 1.038 g. The difference in this case was minimal (0.006 g), and the final moisture content value was 0.57%MC (Figure 6), where %MC is the amount of moisture present in a material, represented as a percentage of the material’s mass, calculated in accordance with Equation (2) [41]:
M C = W W D W W W 100 ( % )
where MC is moisture content, WW is wet weight and DW is dry weight.
Considering the measurement results, it was possible to conclude that the material met the requirements for 3D printing; therefore, its moisture content should not be the cause of failure in the production process or of poor quality of the samples.
Subsequently, the mechanical properties of the supplied filament were verified. The filament properties (ultimate strength, yield strength, Young’s modulus and ductility) under tensile loading were tested on Testometric X350-5 (Rochdale, UK) (Figure 7a) in accordance with ASTM D638 [42] at an ambient temperature of 19 °C and with a jaw speed of 50 mm/min, where the filament length was 100 mm, and testing was repeated 6 times.
The measured force dependences on displacement are presented in Figure 7b. The average ultimate tensile strength reach a value of 85.35 MPa, which corresponds to the value provided by the manufacturer in the material data sheet.

4.2. Investigation of the Manufacturability of Nylon 12 CF Cellular Slurries

4.2.1. Determination of the Volume Fraction of the Material

Once the filament properties were verified, the next phase of the research focused on the manufacturability of the samples with the selected cellular structures. Since one of the challenges of the implementation of porous structures is to lighten the components (while maintaining other required criteria related to physical and functional properties), it was also an effort in the presented research to keep the volume fraction of the material as low as possible. For the determination of the minimum volume fraction, Vf, and for the investigation of the manufacturability of cellular structures made of Nylon 12 CF, volume fractions in the range of 10% to 40% were chosen, while the specimens were manufactured with dimensions of 20 × 20 × 20 mm. The change in volume fraction was controlled by varying the wall thickness in the structure while maintaining the cell size at 10 × 10 × 10 mm.
The wall thicknesses for each type of structure and for the given material volume fractions were defined using virtual 3D models in the PTC Creo 10.0 software environment and are listed in Table 2.
The fabricated structures were observed under a Celestron microscope with a resolution of 10×–150×, and photographs of the observations along with a description of the defects are shown in Table 3.
The setting value of the volume fraction, Vf = 30%, for the final samples with cellular structures intended for bending testing was determined gradually, while the volume fraction of 10% was considered the minimum for the production of TPMS structures from plastic based on the experience of the authors gained from previous research. However, the given material is specific (due to carbon fiber reinforcement), and after the first attempts to make samples with this volume fraction, it was observed that their quality was very poor. Therefore, the volume fraction was gradually increased and the quality of the produced samples was checked.
As can be seen from Table 3, the deficiencies are mainly visible at a glance for the models containing a lower volume fraction (10% and 20%), for each of the selected TPMS structures. The most common error that occurred was associated with omitted layers or layers that did not interlock. Another of the visible defects was the edges of the sample characterized by a large amount of unevenness, especially at a 10% volume fraction for all three selected TPMS structures.
With a subsequent increase in material volume to 30%, the surface quality and detail improved significantly, and defects and irregularities were largely eliminated. Where imperfections were present, these were most often at the edges of the specimens where the carbon fibers did not adhere sufficiently to the basic structural unit of the specimen.
It could be concluded that the samples at Vf = 30% showed good quality, but it was worth investigating the quality at a 40% volume fraction and critically assessing whether or not the potential improvements in quality would balance out the material’s consumption and weight increase for future applications. It turned out that the difference in quality between samples with 30% and 40% volume fractions was only minimal, even for the Schwarz Diamond structure (Table 3); the paradox was that at a 40% volume, gaps were visible on the surface that were not observed at a 30% volume fraction.
Despite the occasional occurrence of minor defects, it was possible to conclude that the quality of the samples with Vf = 30% was comparable to the quality of samples with Vf = 40%, while the differences were only minimal. Considering the above, a volume fraction of 30% was chosen for the production of final samples with cellular structures, which were intended for the study of bending properties.

4.2.2. Impact of Support Structures on Manufacturability

TPMS-type structures are self-supporting, so no support material should be required for 3D printing. On the other hand, as mentioned in the previous chapter, due to the reinforcing fibers in the matrix of the base material, the geometry of the structures and the surface of the samples appeared not “clean” enough, and therefore the question arose as to whether or not support structures, especially used in additive manufacturing processes for samples with complex geometries, could help to improve the quality of the investigated samples generated with the help of cellular structures. Therefore, within the framework of the presented research, samples were also fabricated with the SR-30 Support Filament material, and its removal after fabrication was re-incorporated via dissolution at 65 °C using MakerBot Method Wash Tank (MakerBot, New York, NY, USA). The temperature was set based on the Nylon 12 CF material manufacturer’s recommendations so that only the support material, which was from MakerBot METHOD X SR-30 Support Filament, was dissolved.
Table 4 shows examples of samples with a Vf = 30% volume fraction produced with and without the support material.
By examining the samples and comparing them, it was possible to conclude that the samples produced with the support material did not show a significant increase in quality compared with the samples produced without the support material.
In view of the above, as well as due to the higher economic and time requirements for producing specimens with support material (higher material consumption, time consumed the for preparation and removal of structures, etc.), the final specimens for flexural testing were produced without support structures and additional support material.

4.3. Effect of Production Conditions on the Quality of Samples

4.3.1. Effect of Ambient Temperature on Sample Quality

In the context of the research steps already carried out, and considering the findings of deficiencies related to the lack of material in the individual layers and the associated probable lack of adhesion of the material, research into the effect of the temperature of the printer’s working environment on the quality of the samples was subsequently carried out in the next phase.
Insufficient adhesion of the applied layers results in a heterogeneity of their properties and in the behavior of the samples under load, which was also proven by certain authors in their research [39]. In the case of plastic materials, this means that there was insufficient heating of the previous layer and mixing of the material in the new layer with the material in the previous one, which is currently being resolved by the authors with patents PP50069-2022 and PCT/SK2023/050030, and utility model PUV50104-2022, titled “Method of heat treatment of materials with control of spatial arrangement” [43,44,45]. Due to physical principles, it was therefore not important to decrease the temperature; on the contrary, it was necessary to increase the basic temperature recommended by the manufacturer and then compare the achieved quality of the samples.
The base temperature of the 3D printer chamber during the production of the Nylon 12 CF samples was chosen to be 60 °C, which is the temperature recommended by the material manufacturer and listed in the material sheet. For comparison of the print quality results, temperatures of 65 °C and 70 °C were further selected.
The comparison of the quality of the samples was carried out through observation under Celestrom 10×–150× Digital Microscope, with the samples printed at 65 °C showing an improvement in the surface quality and continuity of the layers (Table 5). A further temperature increase of 5 °C brought about a further deterioration in quality, with more defects on the surface and edges, and in layer continuity.

4.3.2. Effect of Filament Feeding Method on Sample Quality

Another problem that had to be addressed during the sample production process was the frequent jamming of the material. As it was a specific material not only characterized by high abrasiveness, but also lower elasticity and high brittleness compared with materials such as ABS, PLA or PETG, while the base matrix of the material contained carbon particles, problems arose with the unwinding of the filament and its smooth feeding. This problem did not arise when other materials were used in the printer, so effects such as nozzle fouling or material build-up on the walls of the tube in the extruder could be eliminated.
By analyzing the problem and observing the behavior of the filament during the 3D printing of the samples, it was found that the cause of filament jamming was its deposition. This type of printer offers two ways to deposit the filament spool. Since Nylon 12 CF is highly susceptible to moisture, the primary choice was to place the material in the tray at the bottom of the printer (Figure 8a), which was closed. However, the properties of the filament, combined with the long path of the filament into the nozzle, caused problems with unwinding and with the smoothness of the filament dispensing into the extruder. Using a second method of placing the material in a rack at the top of the printer solved the problem (Figure 8b).
Other settings of the production parameters were based on the recommendations of both the filament manufacturer and the printer, and after verifying their suitability for the production of the selected cellular samples, the resulting print parameters were set to the values shown in Table 6.
The result of the complex process of setting the input parameters was a significant improvement in the quality of the samples compared with that of the initially produced ones, as shown in Figure 9.
Following the UltiMaker (Utrecht, The Netherlands) filament manufacturer’s recommendation, the fabricated samples were subjected to a low-temperature annealing process to remove stresses as part of the post-processing process, which was carried out at 82 °C for 5 h (Figure 10) [46].

4.3.3. Effect of Sample Placement in the Printer Workspace

After tuning the input conditions, it was necessary to produce the final specimens for flexural testing measuring 20 × 20 × 250 mm. Due to the 152 × 190 × 196 mm workspace of the 3D printer, the models were positioned diagonally on the work pad, and both directions were tested. As can be seen in Figure 11, the results clearly indicated that the positioning of the sample in the workspace had an impact on its quality. Since we used a closed printer, the influence of external conditions was excluded. A possible cause of sample surface deterioration, which will need to be considered when producing other types of samples, is the airflow generated inside the printer, which may cause defects associated with the faster cooling of the individual layers or filament at the point of deposition.

5. Testing of Specimens under Bending Load

5.1. Experimental Results

For flexural testing, nine specimens in total with a 30% volume fraction were produced (three specimens each for all three structure types studied—Schwarz Diamond, Schoen Gyroid and Schwarz Primitive).
During testing, the force versus deflection dependencies were recorded, the representative curves of which are plotted in Figure 12, with the results of the repeated testing of the same type of specimens showing comparable values and the dependency curves differing only minimally.
The measured force dependences on deflection were for individual structures described by a polynomial function with a high coefficient of determination (R2) as follows:
Schwarz Diamond (R2 = 0.9952)
y = −0.0000004x6 + 0.0000626x5 − 0.0041344x4 + 0.1314913x3 − 2.3513441x2 + 26.5747373x − 1.1968865
Schoen Gyroid (R2 = 0.9949)
y = 0.0025x3 − 0.3042x2 + 10.413x + 4.3398
Schwarz Primitive (R2 = 0.9999)
y = −0.0000004x6 + 0.0000287x5 − 0.0011107x4 + 0.0345008x3 − 0.9437999x2 + 18.5008764x + 1.0870565
The Schwarz Primitive structure required the highest force to break the specimen at 168 N, and the Schoen Gyroid structure required the lowest (115.6 N), but in terms of deflection, the highest value of 58.25 mm was measured for the Schwarz Diamond structure. The results indicates that the Schwarz Diamond structure is the most ductile structure and that the Schwarz Primitive structure exhibits the most brittle behavior amongst the structures investigated from the material.
In terms of linear elasticity, the entire deformation work is converted into elastic tension energy. Based on the energy approach, the three-point flexural test can also be used to determine the modulus of elasticity, E (Young’s modulus, MPa), the bending stiffness (N/m) and the flexural rigidity (Nm2). If the elastic deflection, ue, is expressed by the equation
u e = F e l 3 48 E I ( mm ) ,
then Young’s modulus can be expressed as
E = F e l 3 48 u e I ( MPa ) ,
where Fe denotes the applied elastic force (N), l is a supporting span and I is the area moment of inertia.
The moduli of elasticity in flexure for individual types of cellular structured beams were calculated in accordance with Equation (7), and they are listed in Table 7. For the calculations, the area moment of inertia of the specimen, I, was determined using the software PTC Creo, as shown in Figure 13, while the elastic force, Fe, and elastic deflection, ue, were specified based on measured data.
As can be seen from Table 7, the highest values of evaluated parameters that characterize the strength and plasticity of the structures were achieved for the Schwarz Diamond structure, and the lowest values were obtained for the Shoen Gyroid structure.

5.2. Energy Absorption and Ductility Assesment

The behavior of the selected cellular structures during testing was closely assessed using the amount of energy absorption and ductility indexes [47].
The total energy absorption was calculated as the area under the force–deflection curve [48] by integrating the trend equation, which was expressed by a polynomial function, as seen in Figure 14a. The results for all three types of samples with cellular structures are presented in the histogram in Figure 14b.
The ductility of the beams was evaluated via two indices: µd and µE. The index µd represents the ratio between the deflection at the ultimate load, uu (mm), and the deflection at the elastic limit, ue (mm), according to Formula (8) [49]:
μ d = u u   u e
The ductility index, µE, represents the quotient of the total and elastic energy, and it is expressed by Equation (9) [50,51]:
μ E = 1 2 W t o t W e + 1
-
Wtot is the total energy absorbed by the sample during bending (J);
-
We is the elastic energy (fraction of total) absorbed by the sample up to the elastic limit (J).
Results for both calculated types of indexes were plotted, and they are presented in Figure 15.
It can be seen from the histograms in Figure 14b and Figure 15 that the Schwarz Diamond structure can absorb the greatest amount of energy under stress, while the Schwarz Primitive is able to absorb the smallest amount. Ductility indexes pointed out similar results, although for the quotient of the total and elastic energy, the Shoen Gyroid structure achieved the maximal value. The results indicate that the most brittle behavior among the studied structures was shown by the Schwarz Primitive and that the most ductile behavior was shown by the Schwarz Diamond structure.

6. Conclusions

Porous structures can bring many advantages to a component. In addition to being lightweight, they can save the amount of material used and provide components with extraordinary properties in terms of maintaining functionality, reliability and safety. It is therefore very important to know their behavior in advance even before they are introduced into real practice.
The aim of this paper was to investigate three types of porous structures that belong to the so-called group of triply periodic minimal surfaces and to compare their bending properties. This study was carried out in synergy with a comprehensive preliminary investigation of the effect of the input parameters of 3D printing (the FDM technique) on the quality of samples produced from Nylon 12 CF material using a selected 3D printer available in the authors’ workplace.
To set up the input parameters, the samples were produced using the FDM technique with sizes of 20 × 20 × 20 mm within the preliminary investigation, while for the study of bending properties, the sizes of cellular specimens were 20 × 20 × 250 mm.
The results showed that for a given combination of materials and a 3D printing machine, the minimum volume fraction of the selected cell samples was Vf = 30% while maintaining good sample quality. At this volume fraction, supports do not play a sufficient role in improving quality, so the samples were made to be self-supporting.
It was also found that setting the temperature to 65 °C in the 3D printer workspace during sample production resulted in better sample quality compared with that under the 60 °C temperature recommended by the filament manufacturer. Two other issues that had an impact on the quality of the structures were investigated within the presented research, i.e., the type of storage of the spool with a filament during the operation of the printer and also the positioning of the sample on the pad.
By experimentally testing the bending behavior of the selected cellular structures, it was found that although the highest force (168 N) needed to cause failure in sample was measured for the Schwarz Primitive structure, this structure showed the most brittle behavior. On the contrary, the largest amount of energy (5.84 J) was able to be absorbed by the sample of the Schwarz Diamond structure, which from a comprehensive point of view appears to be the most suitable for applications with Nylon 12 CF under bending stress.
The obtained results and experience will be able to be used in the near future in the simulation of the 3D printing process and the behavior of structures using numerical analyses.

Author Contributions

Conceptualization, K.M.; methodology, K.M.; software, M.K. and K.M.; validation, P.B. and P.P.M.; formal analysis, P.P.M. and J.T.; investigation, M.K., K.M. and J.T.; resources, M.K., K.M. and B.M.; data curation, P.P.M., P.B. and B.M.; writing—original draft preparation, M.K. and K.M.; writing—review and editing, B.M. and P.P.M.; visualization, M.K., J.T. and P.B.; supervision, K.M.; project administration, K.M.; funding acquisition, K.M. and P.P.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Ministry of Education, Science, Research and Sport of the Slovak Republic under grant APVV-19-0550.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Acknowledgments

The article was prepared thanks to the support of the Ministry of Education, Science, Research and Sport of the Slovak Republic through the APVV-19-0550 and KEGA 032TUKE-4/2022, and by the Erasmus+ EU program for education, training, youth and sport through grant ERASMUS+ 2021-1-PL01-KA220-HED-000031182.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Benedetti, M.; du Plessis, A.; Ritchie, R.O.; Dallago, M.; Razavi, N.; Berto, F. Architected cellular materials: A review on their mechanical properties towards fatigue-tolerant design and fabrication. Mater. Sci. Eng. R Rep. 2021, 144, 100606. [Google Scholar] [CrossRef]
  2. Muminovic, A.J. Failure analysis of nylon gears made by additive manufacturing. Eng. Fail. Anal. 2022, 137, 106272. [Google Scholar] [CrossRef]
  3. Grbović, A.; Kastratović, G.; Božić, Ž.; Božić, I.; Obradović, A.; Sedmak, A.; Sedmak, S. Experimental and numerical evaluation of fracture characteristics of composite material used in the aircraft engine cover manufacturing. Eng. Fail. Anal. 2022, 137, 106286. [Google Scholar] [CrossRef]
  4. Pantazopoulos, G.A. A Short Review on Fracture Mechanisms of Mechanical Components Operated under Industrial Process Conditions: Fractographic Ana-lysis and Selected Prevention Strategies. Metals 2019, 9, 148. [Google Scholar] [CrossRef]
  5. Kadkhodapour, J.; Montazerian, H.; Darabi, A.C.; Anaraki, A.P.; Ahmadi, S.M.; Zadpoor, A.A.; Schmauder, S. Failure mechanisms of additively manufactured porous biomaterials. J. Mech. Behav. Biomed. Mater. 2015, 50, 180–191. [Google Scholar] [CrossRef]
  6. Stamoulis, K.; Panagiotopoulos, D.; Pantazopoulos, G.; Papaefthymiou, S. Failure analysis of an aluminum extrusion aircraft wing component. Int. J. Struct. Integr. 2016, 7, 748–761. [Google Scholar] [CrossRef]
  7. Munsch, M. Laser additive manufacturing of customized prosthetics and implants for biomedical applications. In Laser Additive Manufacturing; Brandt, M., Ed.; Elsevier: Amsterdam, The Netherlands, 2017; pp. 399–420. [Google Scholar]
  8. Yang, J.; Gu, D.; Lin, K.; Wu, L.; Zhang, H.; Guo, M.; Yuan, L. Laser additive manufacturing of cellular structure with enhanced com-pressive performance inspired by Al–Si crystalline microstructure. CIRP J. Manuf. Sci. Technol. 2021, 32, 26–36. [Google Scholar] [CrossRef]
  9. Nazir, A.; Abate, K.M.; Kumar, A.; Jeng, J.-Y. A state-of-the-art review on types, design, optimization, and additive manufactu-ring of cellular structures. Int. J. Adv. Manuf. Technol. 2019, 104, 3489–3510. [Google Scholar] [CrossRef]
  10. Nemes-Károly, I.; Szebényi, G. Reliable Methods for Classification, Characterization, and Design of Cellular Structures for Patient-Specific Implants. Materials 2023, 16, 4146. [Google Scholar] [CrossRef]
  11. Ghanbari-Ghazijahani, T.; Kasebahadi, M.; Hassanli, R.; Classen, M. 3D printed honeycomb cellular beams made of composite materials (plastic and timber). Constr. Build. Mater. 2022, 315, 125541. [Google Scholar] [CrossRef]
  12. Calignano, F.; Lorusso, M.; Roppolo, I.; Minetola, P. Investigation of the Mechanical Properties of a Carbon Fibre-Reinforced Nylon Filament for 3D Printing. Machines 2020, 8, 52. [Google Scholar] [CrossRef]
  13. Nguyen-Van, V.; Choudhry, N.K.; Panda, B.; Nguyen-Xuan, H.; Tran, P. Performance of concrete beam reinforced with 3D printed Bioinspired primitive scaffold subjected to three-point bending. Autom. Constr. 2022, 134, 104060. [Google Scholar] [CrossRef]
  14. Ormiston, S.; Srinivas Sundarram, S. Fiberglass-reinforced triply periodic minimal surfaces (TPMS) lattice structures for ener-gy absorption applications. Polym. Compos. 2023, 45, 523–534. [Google Scholar] [CrossRef]
  15. Alarifi, I.M. A performance evaluation study of 3d printed nylon/glass fiber and nylon/carbon fiber composite materials. J. Mater. Res. Technol. 2022, 21, 884–892. [Google Scholar] [CrossRef]
  16. Cui, Z.; Huang, X.; Jia, M.; Panahi-Sarmad, M.; Hossen, I.; Dong, K.; Xiao, X. 3D printing of continuous fiber reinforced cellular structural composites for the study of bending performance. J. Reinf. Plast. Compos. 2023, 42, 673–684. [Google Scholar] [CrossRef]
  17. Myers, D.; Abdel-Wahab, A.; Hafeez, F.; Kovacev, N.; Essa, K. Optimisation of the additive manufacturing parameters of poly-lactic acid (PLA) cellular structures for biomedical applications. J. Mech. Behav. Biomed. Mater. 2022, 136, 105447. [Google Scholar] [CrossRef]
  18. Tao, Y.; Pan, L.; Liu, D.; Li, P. A case study: Mechanical modeling optimization of cellular structure fabricated using wood flour-filled polylactic acid composites with fused deposition modeling. Compos. Struct. 2019, 216, 360–365. [Google Scholar] [CrossRef]
  19. Zhang, Y.; Liu, B.; Peng, F.; Jia, H.; Zhao, Z.; Duan, S.; Wang, P.; Lei, H. Adaptive enhancement design of triply periodic minimal surface lattice structure based on non-uniform stress distribution. Appl. Math. Mech. 2023, 44, 1317–1330. [Google Scholar] [CrossRef]
  20. Zhu, J.; Zou, S.; Mu, Y.; Wang, J.; Jin, Y. Additively Manufactured Scaffolds with Optimized Thickness Based on Triply Periodic Minimal Surface. Materials 2022, 15, 7084. [Google Scholar] [CrossRef]
  21. Yu, S.; Sun, J.; Bai, J. Investigation of functionally graded TPMS structures fabricated by additive manufacturing. Mater. Des. 2019, 182, 108021. [Google Scholar] [CrossRef]
  22. Abueidda, D.W.; Elhebeary, M.; Shiang, C.-S.; Pang, S.; Abu Al-Rub, R.K.; Jasiuk, I.M. Mechanical properties of 3D printed polymeric Gyroid cellular structures: Experimental and finite element study. Mater. Des. 2019, 165, 107597. [Google Scholar] [CrossRef]
  23. Han, L.; Che, S. An overview of materials with triply periodic minimal surfaces and related geometry: From biological structures to self-assembled systems. Adv. Mater. 2018, 30, e1705708. [Google Scholar] [CrossRef]
  24. Callens, S.J.P.; Tümer, N.; Zadpoor, A.A. Hyperbolic origami-inspired folding of triply periodic minimal surface structures. Appl. Mater. Today 2019, 15, 453–461. [Google Scholar] [CrossRef]
  25. Awd, M.; Saeed, M.; Walther, F. A review on the enhancement of failure mechanisms modeling in additively manufactured structures by machine learning. Eng. Fail. Anal. 2023, 151, 107403. [Google Scholar] [CrossRef]
  26. Hassan, I.M.; Enab, T.A.; Fouda, N.; Eldesouky, I. The mechanical performance of functionally graded Schwarz primitive and Schoen-IWP cellular structures fabricated by additive manufacturing. Prog. Addit. Manuf. 2023, 8, 303–311. [Google Scholar] [CrossRef]
  27. Mishra, A.M.; Kumar, A. Performance of asymmetric octet lattice structures under compressive and bending loads. Eng. Fail. Anal. 2023, 154, 107669. [Google Scholar] [CrossRef]
  28. Guo, X.; Ding, J.; Li, X.; Qu, S.; Song, X.; Fuh, J.Y.H.; Lu, W.F.; Zhai, W. Enhancement in the mechanical behaviour of a Schwarz Primitive periodic minimal surface lattice structure design. Int. J. Mech. Sci. 2022, 216, 106977. [Google Scholar] [CrossRef]
  29. Kladovasilakis, N.; Tsongas, K.; Tzetzis, D. Mechanical and FEA-Assisted Characterization of Fused Filament Fabricated Triply Periodic Minimal Surface Structures. J. Compos. Sci. 2021, 5, 58. [Google Scholar] [CrossRef]
  30. Restrepo, S.; Ocampo, S.; Ramírez, J.A.; Paucar, C.; García, C. Mechanical properties of ceramic structures based on Triply Periodic Minimal Surface (TPMS) processed by 3D printing. J. Phys. Conf. Ser. 2017, 935, 012036. [Google Scholar] [CrossRef]
  31. Downing, D.; Jones, A.; Brandt, M.; Leary, M. Increased efficiency gyroid structures by tailored material distribution. Mater. Des. 2021, 197, 109096. [Google Scholar] [CrossRef]
  32. Papadopoulou, S.; Vazdirvanidis, A.; Toulfatzis, A.; Rikos, A.; Pantazopoulos, G. Failure Investigation of Products and Components in Metal Forming Industry: Root Cause Analysis and Process-Based Approach. J Fail. Anal. and Preven. 2020, 20, 106–114. [Google Scholar] [CrossRef]
  33. Korol’, M.; Török, J.; Goryl, K.; Vodilka, A. Research of Selected TPMS Structures Made of ABS and Nylon 12 CF Material Using the FDM, Advances in Manufacturing IV. In Lecture Notes in Mechanical Engineering; Springer: Cham, Switzerland, 2024. [Google Scholar] [CrossRef]
  34. Monkova, K.; Monka, P.P.; Vodilka, A. Comparison of the Bending Behavior of Cylindrically Shaped Lattice Specimens with Radially and Orthogonally Arranged Cells Made of ABS. Polymers 2024, 16, 979. [Google Scholar] [CrossRef]
  35. ISO 178:2019 Standard; Plastics Determination of Flexural Properties. ISO: Geneva, Switzerland, 2019.
  36. Rodríguez-Reyna, S.; Díaz-Aguilera, J.; Acevedo-Parra, H.; García, C.J.; Gutierrez-Castañeda, E.J.; Tapia, F. Design and optimization methodology for different 3D processed materials (PLA, ABS and carbon fiber reinforced nylon PA12) subjected to static and dynamic loads. J. Mech. Behav. Biomed. Mater. 2024, 150, 106257. [Google Scholar] [CrossRef] [PubMed]
  37. Vidakis, N.; Petousis, M.; Velidakis, E.; Tzounis, L.; Mountakis, N.; Boura, O.; A Grammatikos, S. Multi-functional polyamide 12 (PA12)/multiwall carbon nanotube 3D printed nanocomposites with enhanced mechanical and electrical properties. Adv. Compos. Mater. 2022, 31, 630–654. [Google Scholar] [CrossRef]
  38. Kahraman, M.F.; İriç, S.; Genel, K. Comparative failure behavior of metal honeycomb structures under bending: A finite element-based study. Eng. Fail. Anal. 2024, 157, 107963. [Google Scholar] [CrossRef]
  39. Vanca, J.; Monkova, K.; Žaludek, M.; Monka, P.P.; Koroľ, M.; Kozak, D.; Beno, P.; Ferroudji, F. Investigation of the Influence of Orientation on the Tensile Pro-perties of 3D Printed Samples with Gyroid Structure. In Proceedings of the 13th International Conference on Mechanical and Aerospace Engineering, Bratislava, Slovakia, 20–22 July 2022; Institute of Electrical and Electronics Engineers: New York, NY, USA, 2022; pp. 526–531, ISBN 978-1-6654-7234-0. [Google Scholar]
  40. Dazon, C.; Witschger, O.; Llewellyn, P.L. Performance of the halogen technology for determining the moisture content of nanoparticulate powders. Exp. Tech. 2019, 43, 757–764. [Google Scholar] [CrossRef]
  41. Seyedzavvar, M.; Boğa, C.; Zehir, B. Experimental study and hybrid optimization of material extrusion process parameters for enhancement of fracture resistance of biodegradable nanocomposites. Eng. Fail. Anal. 2023, 150, 107294. [Google Scholar] [CrossRef]
  42. ASTM D638; Standard Test Method for Tensile Properties of Plastics. ASTM International: West Conshohocken, PA, USA, 2022.
  43. Monka, P.P.; Monkova, K. Method of Heat Treatment of Materials with Control of Spatial Arrangement. National Patent PP50069-2022, 20 December 2022. [Google Scholar]
  44. Monka, P.P.; Monkova, K. Method of Heat Treatment of Materials with Control of Spatial Arrangement. International Patent PCT/SK2023/050030, 15 October 2023. [Google Scholar]
  45. Monka, P.P.; Monkova, K. Method of Heat Treatment of Materials with Control of Spatial Arrangement. Utility model PUV50104-2022, 20 December 2022. [Google Scholar]
  46. Valvez, S.; Reis, P.N.B.; Ferreira, J.A.M. Effect of annealing treatment on mechanical properties of 3D-Printed composites. J. Mater. Res. Technol. 2023, 23, 2101–2115. [Google Scholar] [CrossRef]
  47. Kožar, I.; Sulovsky, T.; Plovanić, M.; Božić, Ž. Verification of a displacement model for three-point bending test. Procedia Struct. Integr. 2023, 46, 143–148. [Google Scholar] [CrossRef]
  48. Monkova, K.; Monka, P.P.; Žaludek, M.; Beňo, P.; Hricová, R.; Šmeringaiová, A. Experimental Study of the Bending Behaviour of the Neovius Porous Structure Made Additively from Aluminium Alloy. Aerospace 2023, 10, 361. [Google Scholar] [CrossRef]
  49. Subhani, M.; Globa, A.; Al-Ameri, R.; Moloney, J. Flexural strengthening of LVL beam using CFRP. Constr. Build. Mater. 2017, 150, 480–489. [Google Scholar] [CrossRef]
  50. Nabavi-Kivi, A.; Ayatollahi, M.R.; Schmauder, S.; Khosravani, M.R. Fracture analysis of a 3D-printed ABS specimen: Effects of raster angle and layer orientation. Fiz. Mezomekhanika 2022, 25, 26–39. [Google Scholar] [CrossRef]
  51. Kim, T.-K.; Park, J.-S. Evaluation of the Performance and Ductility Index of Concrete Structures Using Advanced Composite Material Strengthening Methods. Polymers 2021, 13, 4239. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Categories of cellular structures.
Figure 1. Categories of cellular structures.
Polymers 16 01429 g001
Figure 2. Investigated structures’ arrangement with their basic cells: (a) Schwarz Diamond; (b) Schwarz Primitive; (c) Schoen Gyroid.
Figure 2. Investigated structures’ arrangement with their basic cells: (a) Schwarz Diamond; (b) Schwarz Primitive; (c) Schoen Gyroid.
Polymers 16 01429 g002
Figure 3. Samples for experimental testing: (a) Schwarz Diamond, (b) Schoen Gyroid and (c) Schwarz Primitive.
Figure 3. Samples for experimental testing: (a) Schwarz Diamond, (b) Schoen Gyroid and (c) Schwarz Primitive.
Polymers 16 01429 g003
Figure 4. Test set-up; (a) Zwick 1456 machine; (b) a specimen positioning within bending test.
Figure 4. Test set-up; (a) Zwick 1456 machine; (b) a specimen positioning within bending test.
Polymers 16 01429 g004
Figure 5. Filament moisture measurement: (a) Halogen HR83 moisture measuring instrument; (b) the material that was tested in the weighing pan.
Figure 5. Filament moisture measurement: (a) Halogen HR83 moisture measuring instrument; (b) the material that was tested in the weighing pan.
Polymers 16 01429 g005
Figure 6. Measurement of moisture content of material Nylon 12 CF.
Figure 6. Measurement of moisture content of material Nylon 12 CF.
Polymers 16 01429 g006
Figure 7. Tensile testing of filament: (a) tensile test set up; (b) measured force-displacement dependences.
Figure 7. Tensile testing of filament: (a) tensile test set up; (b) measured force-displacement dependences.
Polymers 16 01429 g007
Figure 8. Filament feeding method: (a) placement of the material in the tray at the bottom of the printer; (b) placement of the material in the rack at the top of the printer.
Figure 8. Filament feeding method: (a) placement of the material in the tray at the bottom of the printer; (b) placement of the material in the rack at the top of the printer.
Polymers 16 01429 g008
Figure 9. Results of improved technological conditions (Nylon 12 Carbon Fiber).
Figure 9. Results of improved technological conditions (Nylon 12 Carbon Fiber).
Polymers 16 01429 g009
Figure 10. Annealing process of a sample inside of the workspace of the 3D printer machine.
Figure 10. Annealing process of a sample inside of the workspace of the 3D printer machine.
Polymers 16 01429 g010
Figure 11. (a) Saving the sample in software as part of preprocessing before printing; (b) surface of the sample after printing under a Celestrom microscope at 40× magnification and with a 2 MP CMOS resolution.
Figure 11. (a) Saving the sample in software as part of preprocessing before printing; (b) surface of the sample after printing under a Celestrom microscope at 40× magnification and with a 2 MP CMOS resolution.
Polymers 16 01429 g011aPolymers 16 01429 g011b
Figure 12. Representative force versus deflection curves obtained from experimental tests of specimens with cellular structures under bending loading.
Figure 12. Representative force versus deflection curves obtained from experimental tests of specimens with cellular structures under bending loading.
Polymers 16 01429 g012
Figure 13. Specification of the area moment of inertia, I.
Figure 13. Specification of the area moment of inertia, I.
Polymers 16 01429 g013
Figure 14. (a) Energy absorption during bending; (b) energy absorption during bending, elastic; ductility indexes, µd, based on the deflection value at the proportionality limit. µE is expressed as the quotient of the total and elastic energy.
Figure 14. (a) Energy absorption during bending; (b) energy absorption during bending, elastic; ductility indexes, µd, based on the deflection value at the proportionality limit. µE is expressed as the quotient of the total and elastic energy.
Polymers 16 01429 g014
Figure 15. Ductility indexes, µd, based on the deflection value at the proportionality limit. µE is expressed as the quotient of the total and elastic energy.
Figure 15. Ductility indexes, µd, based on the deflection value at the proportionality limit. µE is expressed as the quotient of the total and elastic energy.
Polymers 16 01429 g015
Table 1. Properties of Nylon 12 CF [36,37].
Table 1. Properties of Nylon 12 CF [36,37].
Properties
Density1.5 g/cm3
Melting point180–190 °C
Temperature resistance
(continuous)
−40 °C až 120 °C
Temperature resistance
(short term)
180 °C
Tensile modulus of elasticity10 GPa
Tensile strength83.5 MPa
Elongation at break10%
Impact toughness50 kJ/m2
Table 2. Wall thicknesses for individual structure types and material volume fractions.
Table 2. Wall thicknesses for individual structure types and material volume fractions.
Volume FractionType of StructureCell-Wall Thickness
10%Shoen Gyroid0.52 mm
Schwarz Diamond0.36 mm
Schwarz Primitive0.43 mm
20%Shoen Gyroid0.70 mm
Schwarz Diamond0.55 mm
Schwarz Primitive0.88 mm
30%Shoen Gyroid1.02 mm
Schwarz Diamond0.83 mm
Schwarz Primitive1.33 mm
40%Shoen Gyroid1.37 mm
Schwarz Diamond1.12 mm
Schwarz Primitive1.79 mm
Table 3. View of samples under a Celestrom microscope (Torrance, CA, USA) with a 40× magnification and 2 MP CMOS resolution.
Table 3. View of samples under a Celestrom microscope (Torrance, CA, USA) with a 40× magnification and 2 MP CMOS resolution.
StructureVolume FractionView under the MicroscopeDetail of ErrorsError Description
Diamond10%Polymers 16 01429 i001Excessively large gaps between layers
20%Polymers 16 01429 i002Tasseled surface on the edges of the sample
30%Polymers 16 01429 i003Better continuity of layers, slightly fringed edges
40%Polymers 16 01429 i004Large gaps between layers
Gyroid10%Polymers 16 01429 i005Excessively large omission of material caused by thin walls
20%Polymers 16 01429 i006Slightly better surface of the sample compared to 10% + frayed ends of the sample
30%Polymers 16 01429 i007Gaps between layers on the surface
40%Polymers 16 01429 i008Better layer continuity versus lower volume fraction
Primitive10%Polymers 16 01429 i009Very frequent omission of details and layering of material has too-large gaps
20%Polymers 16 01429 i010Excessively large gaps between layers
30%Polymers 16 01429 i011Visibly better surface, better printed details, and minimal surface defects
40%Polymers 16 01429 i012Visible omission of material between layers and reduced compactness
Table 4. Comparison of surface quality after printing with/without support material using a Celestrom microscope with a 40× magnification and 2 MP CMOS resolution.
Table 4. Comparison of surface quality after printing with/without support material using a Celestrom microscope with a 40× magnification and 2 MP CMOS resolution.
Type of StructureSample Made with Support
Material
Sample Made without Support Material
Diamond 30%Polymers 16 01429 i013Polymers 16 01429 i014
Gyroid 30%Polymers 16 01429 i015Polymers 16 01429 i016
Primitive 30%Polymers 16 01429 i017Polymers 16 01429 i018
Table 5. View of samples under Celestrom microscope at different chamber temperatures, at a 40× magnification and with a 2 MP CMOS resolution.
Table 5. View of samples under Celestrom microscope at different chamber temperatures, at a 40× magnification and with a 2 MP CMOS resolution.
StructureTemperature of the ChamberView under the MicroscopeDetail of the ErrorProblem Description
Diamond60 °CPolymers 16 01429 i019Tasseled surface around the edges of the sample
65 °CPolymers 16 01429 i020Better surface and layer continuity, and visibly improved sample integrity
70 °CPolymers 16 01429 i021Visible deterioration of the sample surface compared to that under 65 °C
Gyroid60 °CPolymers 16 01429 i022The surface shows a number of irregularities and dimensional changes after remeasurement
65 °CPolymers 16 01429 i023In contrast to that of the sample printed at 60 °C, the surface was more homogeneous
70 °CPolymers 16 01429 i024Larger gaps between layers in contrast to the print at 65 °C
Primitive60 °CPolymers 16 01429 i025The surface contained a number of gaps and defects, which made the sample appear less whole
65 °CPolymers 16 01429 i026There were minimal defects on the samples, and the details were sharper
70 °CPolymers 16 01429 i027Compared with those under 65 °C, the edges were less compact (more fringed)
Table 6. Input parameters before printing started.
Table 6. Input parameters before printing started.
Input ParameterUnitValue
Filament diametermm1.75
Temperature in the printer chamber°C65
Pad temperature°C65
Nozzle diametermm0.4
Travel speedmm/s80
Print speedmm/s35
Layer heightmm0.15
Table 7. Flexural modulus of elasticity.
Table 7. Flexural modulus of elasticity.
Type of StructureModulus of Elasticity (MPa)Bending Stiffness (N/m)Flexural Rigidity (Nm2)
Schwarz Diamond8850.0200872.808642
Schoen Gyroid4920.0100111.669664
Schwarz Primitive6750.0154542.378867
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Koroľ, M.; Török, J.; Monka, P.P.; Baron, P.; Mrugalska, B.; Monkova, K. Researching on the Effect of Input Parameters on the Quality and Manufacturability of 3D-Printed Cellular Samples from Nylon 12 CF in Synergy with Testing Their Behavior in Bending. Polymers 2024, 16, 1429. https://doi.org/10.3390/polym16101429

AMA Style

Koroľ M, Török J, Monka PP, Baron P, Mrugalska B, Monkova K. Researching on the Effect of Input Parameters on the Quality and Manufacturability of 3D-Printed Cellular Samples from Nylon 12 CF in Synergy with Testing Their Behavior in Bending. Polymers. 2024; 16(10):1429. https://doi.org/10.3390/polym16101429

Chicago/Turabian Style

Koroľ, Martin, Jozef Török, Peter Pavol Monka, Petr Baron, Beata Mrugalska, and Katarina Monkova. 2024. "Researching on the Effect of Input Parameters on the Quality and Manufacturability of 3D-Printed Cellular Samples from Nylon 12 CF in Synergy with Testing Their Behavior in Bending" Polymers 16, no. 10: 1429. https://doi.org/10.3390/polym16101429

APA Style

Koroľ, M., Török, J., Monka, P. P., Baron, P., Mrugalska, B., & Monkova, K. (2024). Researching on the Effect of Input Parameters on the Quality and Manufacturability of 3D-Printed Cellular Samples from Nylon 12 CF in Synergy with Testing Their Behavior in Bending. Polymers, 16(10), 1429. https://doi.org/10.3390/polym16101429

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop