Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse
Abstract
:1. Introduction
2. Materials and Methods
2.1. Experimental Setup
2.2. Equipment and Instrumentation
2.3. Theoretical Foundations of Turbulence Characteristics
3. Results
3.1. Description of Airflow throughout the Side Openings
3.1.1. Airflow through the NE Window, before and after Passing through the Insect-Proof Screen
3.1.2. Airflow through the Northern Side Window, before and after Passing through the Insect-Proof Screen
3.2. Influence of the Insect-Proof Screen on the Turbulence of the Airflow
4. Conclusions
Author Contributions
Funding
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Agrafioti, P.; Faliagka, S.; Lampiri, E.; Orth, M.; Pätzel, M.; Katsoulas, N.; Athanassiou, C.G. Evaluation of silica-coated insect proof nets for the control of Aphis fabae, Sitophilus oryzae, and Tribolium confusum. Nanomaterials 2020, 10, 1658. [Google Scholar] [CrossRef] [PubMed]
- Teitel, M. The effect of screened openings on greenhouse microclimate. Agric. For. Meteorol. 2007, 143, 159–175. [Google Scholar] [CrossRef]
- Oliva, R.M.; Álvarez, A.J. Factors influencing the efficacy of insect-proof screens. Acta Hortic. 2017, 1170, 1027–1033. [Google Scholar] [CrossRef]
- Berlinger, M.J.; Leblush-Mordechl, S.; Fridja, D.; Mor, N. The effect of types of greenhouse screens on the presence of western flower thrips: A preliminary study. OILB-SROP Bull. 1992, 16, 13–19. [Google Scholar]
- Taylor, R.A.J.; Shalhevet, S.; Spharim, I.; Berlinger, M.J.; Lebiush-Mordechi, S. Economic evaluation of insect-proof screens for preventing tomato yellow leaf curl virus of tomatoes in Israel. Crop Prot. 2001, 20, 561–569. [Google Scholar] [CrossRef]
- Bethke, J.A.; Paine, T.D. Screen hole size and barriers for exclusion on insect pest of glasshouse crops. J. Entomol. Sci. 1991, 26, 169–177. [Google Scholar] [CrossRef]
- Verheye, P.; Verlodt, H. Comparison of different systems for static ventilation of hemispheric plastic greenhouses. Acta Hortic. 1990, 281, 183–197. [Google Scholar] [CrossRef]
- Von Zabeltitz, C. L’efficacité énergétique dans la conception des serres méditerranéennes. Plasticulture 1992, 96, 6–16. [Google Scholar]
- ANSI/ASAE. EP406.1: Heating, Ventilating, and Cooling Greenhouses; ASAE: St. Joseph, MI, USA, 1994. [Google Scholar]
- Kittas, C.; Boulard, T.; Papadakis, G. Natural ventilation of a greenhouse with ridge and side openings: Sensitivity to temperature and wind effects. Trans. ASAE 1997, 40, 415–425. [Google Scholar] [CrossRef]
- Kittas, C.; Katsoulas, N.; Bartzanas, T.; Mermier, M.; Boulard, T. The impact of insect screens and ventilation openings on the greenhouse microclimate. Trans. ASABE 2008, 51, 2151–2165. [Google Scholar] [CrossRef]
- Formisano, L.; El-Nakhel, C.; Corrado, G.; De Pascale, S.; Rouphael, Y. Biochemical, physiological, and productive response of greenhouse vegetables to suboptimal growth environment induced by insect nets. Biology 2020, 9, 432. [Google Scholar] [CrossRef] [PubMed]
- López-Martínez, A.; Martínez, D.L.V.; Aiz, F.D.M.; Peña, A.; Membrive, P.M. Microclimate evaluation of a new design of insect-proof screens in a Mediterranean greenhouse. Span. J. Agric. Res. 2014, 2, 338–352. [Google Scholar] [CrossRef] [Green Version]
- Harmanto; Tantau, H.J.; Salokhe, V.M. Microclimate and air exchange rates in greenhouses covered with different nets in the humid tropics. Biosyst. Eng. 2006, 94, 239–253. [Google Scholar] [CrossRef]
- Yang, G.; Guo, Z.; Ji, H.; Sheng, J.; Chen, L.; Zhao, Y. Application of insect-proof nets in pesticide-free rice creates an altered microclimate and differential agronomic performance. PeerJ 2018, 6, e6135. [Google Scholar] [CrossRef] [Green Version]
- Teitel, M.; Liang, H.; Vitoshkin, H.; Tanny, J.; Ozer, S. Airflow patterns and turbulence characteristics above the canopy of a tomato crop in a roof-ventilated insect-proof screenhouse. Biosyst. Eng. 2020, 190, 184–200. [Google Scholar] [CrossRef]
- Bartzanas, T.; Boulard, T.; Kittas, C. Numerical simulation of the airflow and temperature distribution in a tunnel greenhouse equipped with insect-proof screen in the openings. Comput. Electron. Agric. 2002, 34, 207–221. [Google Scholar] [CrossRef]
- Fatnassi, H.; Boulard, T.; Demrati, H.; Bouirden, L.; Sappe, G. Ventilation Performance of a Large Canarian-Type Greenhouse equipped with Insect-proof Nets. Biosyst. Eng. 2002, 82, 97–105. [Google Scholar] [CrossRef]
- Fatnassi, H.; Boulard, T.; Bouirden, L. Simulation of climatic conditions in full-scale greenhouse fitted with insect-proof screens. Agric. For. Meteorol. 2003, 118, 97–111. [Google Scholar] [CrossRef]
- Fatnassi, H.; Boulard, T.; Poncet, C.; Chave, M. Optimisation of greenhouse insect screening with computational fluid dynamics. Biosyst. Eng. 2006, 93, 301–312. [Google Scholar] [CrossRef]
- Baeza, E.J.; Pérez-Parra, J.J.; Montero, J.I.; Bailey, B.J.; López, J.C.; Gázquez, J.C. Analysis of the role of sidewall vents on buoyancy-driven natural ventilation in parral-type greenhouses with and without insect screens using computational fluid dynamics. Biosyst. Eng. 2009, 104, 86–96. [Google Scholar] [CrossRef]
- Teitel, M.; Barak, M.; Berlinger, M.J.; Lebiush-Mordechai, S. Insect-proof screens in greenhouses: Their effect on roof ventilation and insect penetration. Acta Hortic. 1999, 507, 25–34. [Google Scholar] [CrossRef]
- López, A.; Martínez, D.L.V.; Aiz, F.D.M.; Peña, A. Sonic anemometry measurements to determine airflow patterns in multi-tunnel greenhouses. Span. J. Agric. Res. 2012, 3, 631–642. [Google Scholar] [CrossRef] [Green Version]
- López-Martínez, A.; Molina-Aiz, F.D.; Valera, D.L.; Peña, A. Wind tunnel analysis of the airflow through insect-proof screens and comparison of their effect when installed in a Mediterranean greenhouse. Sensors 2016, 16, 690. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- López-Martínez, A.; Molina-Aiz, F.D.; Valera, D.L.; Espinoza-Ramos, K.E. Models for characterising the aerodynamics of insect-proof screens from their geometric parameters. Biosyst. Eng. 2020, 192, 42–55. [Google Scholar] [CrossRef]
- Granados-Ortiz, F.-J.; Arrabal-Campos, F.M.; Lopez-Martinez, A.; Molina-Aiz, F.D.; Peña-Fernández, A.; Valera-Martínez, D.L. On the estimation of three-dimensional porosity of insect-proof screens. Comput. Electron. Agric. 2022. in Press. [Google Scholar] [CrossRef]
- Teitel, M.; Tanny, T. Heat Fluxes and Airflow Patterns Through Roof Windows in a Naturally Ventilated Enclosure. Flow Turbul. Combust. 2005, 74, 21–47. [Google Scholar] [CrossRef]
- Pope, S.B. Turbulent Flows; Cambridge University Press: Cambridge, UK, 2000. [Google Scholar]
- Tanny, J.; Haslavsky, V.; Teitel, M. Airflow and heat flux through the vertical opening of buoyancy-induced naturally ventilated enclosures. Energ. Build. 2008, 40, 637–646. [Google Scholar] [CrossRef]
- Valera, D.L.; Álvarez, A.J.; Molina-Aiz, F.D. Aerodynamic analysis of several insect-proof screens used in greenhouses. Span. J. Agric. Res. 2006, 4, 273–279. [Google Scholar] [CrossRef]
- Shilo, E.; Teitel, M.; Mahrer, Y.; Boulard, T. Air-flow patterns and heat fluxes in roof-ventilated multi-span greenhouse with insect-proof screens. Agric. For. Meteorol. 2004, 122, 3–20. [Google Scholar] [CrossRef]
- Von Karman, T. Some remarks on the statistical theory of turbulence. In Proceedings of the fifth International Congress for Applied Mechanics, Cambridge, MA, USA, 12–16 September 1938; p. 347. [Google Scholar]
- Hinze, J.O. Turbulence; McGraw-Hill: New York, NY, USA, 1975. [Google Scholar]
- Chapman, G.T.; MTobak, M. Observations, Theoretical Ideas, and Modeling of Turbulent Flows—Past, Present and Future. In Theoretical Approaches to Turbulence; Dwoyer, D.L., Hussaini, M.Y., Voigt, R.G., Eds.; Springer: New York, NY, USA, 1985; pp. 19–49. [Google Scholar]
- Gustavsson, H. Lecture notes: Introduction to turbulence. In Luleå: Division of Fluid Mechanics; Luleå University of Technology: Luleå, Sweden, 2006. [Google Scholar]
- Cebeci, T. Analysis of Turbulent Flows; Elsevier Science: Amsterdan, The Netherlands, 2004. [Google Scholar]
- Heber, A.J.; Boon, C.R.; Peugh, M.W. Air patterns and turbulence in an experimental livestock building. J. Agric. Eng. Res. 1996, 64, 209–226. [Google Scholar] [CrossRef] [Green Version]
- Maryami, R.; Showkat Ali, S.A.; Azarpeyvand, M.; Afshari, A. Turbulent flow interaction with a circular cylinder. Phys. Fluids 2020, 32, 015105. [Google Scholar] [CrossRef] [Green Version]
- Mora, D.O.; Obligado, M. Estimating the integral length scale on turbulent flows from the zero crossings of the longitudinal velocity fluctuation. Exp. Fluids 2020, 61, 199. [Google Scholar] [CrossRef]
- O’Neill, P.L.; Nicolaides, D.; Honnery, D.; Soria, J. Autocorrelation functions and the determination of integral length with reference to experimental and numerical data. In Proceedings of the 15th Australasian Fluid Mechanics Conference, Sydney, NSW, Australia, 13–17 December 2004; Volume 1, pp. 1–4. [Google Scholar]
- Melikov, A.K.; Langkilde, G.; Derbiszewski, B. Airflow characteristic in the occupied zone of rooms with displacement ventilation. ASHRAE Trans. 1990, 96, 555–563. [Google Scholar]
- Shen, Z.; Zhang, X. Random-eddy-superposition technique for leading edge noise predictions. In Proceedings of the 2018 AIAA/CEAS Aeroacoustics Conference, Atlanta, Georgia, 25–29 June 2018; p. 3597. [Google Scholar]
- Hamba, F. Turbulent energy density in scale space for inhomogeneous turbulence. J. Fluid Mech. 2018, 842, 532–553. [Google Scholar] [CrossRef]
- Ouyang, Q.; Dai, W.; Li, H.; Zhu, Y. Study on dynamic characteristics of natural and mechanical wind in built environment using espectral analisis. Build. Environ. 2006, 41, 418–426. [Google Scholar] [CrossRef]
- Stull, R.B. An Introduction to Boundary Layer Meteorology; Kluwer Academics Publishers: Dordrecht, The Netherlands, 1988. [Google Scholar]
- Laizet, S.; Nedić, J.; Vassilicos, J.C. The spatial origin of −5/3 spectra in grid-generated turbulence. Phys. Fluids 2015, 27, 065115. [Google Scholar] [CrossRef] [Green Version]
- Loomans, M.G.L.C. The Measurement and Simulation of Indoor Air Flow. Master’s Thesis, Technische Universiteit Eindhoven, Eindhoven, The Netherlands, 1998. [Google Scholar]
- Ting, D. Basics of Engineering Turbulence; Academic Press: Cambridge, MA, USA; Elsevier: Amsterdam, The Netherlands, 2016. [Google Scholar]
- Abou-Hweij, W.; Azizi, F. CFD simulation of wall-bounded laminar flow through screens. Part I: Hydrodynamic characterization. Eur. J. Mech.-B/Fluids 2020, 84, 207–232. [Google Scholar] [CrossRef]
- Muñoz, P.; Montero, J.I.; Antón, A.; Giuffrida, F. Effect of insect-proof screens and roof openings on greenhouse ventilation. J. Agric. Eng. Res. 1999, 73, 171–178. [Google Scholar] [CrossRef]
- Teitel, M. The effect of insect-proof screens in roof openings on greenhouse microclimate. Agric. For. Meteorol. 2001, 110, 13–25. [Google Scholar] [CrossRef]
- Molina-Aiz, F.D.; Valera, D.L.; Peña, A.A.; Gil, J.A.; López, A. A Study of Natural Ventilation in an Almería-Type Greenhouse with Insect Screens by Means of Tri-sonic Anemometry. Biosyst. Eng. 2009, 104, 224–242. [Google Scholar] [CrossRef]
- Fang, F. A design method for contractions with square end sections. Trans. ASME 1997, 119, 454–458. [Google Scholar] [CrossRef]
- Fang, F.; Chen, J.C.; Hong, Y.T. Experimental and analytical evaluation of flow in a square-to-square wind tunnel contraction. J. Wind Eng. Ind. Aerodyn. 2001, 89, 247–262. [Google Scholar] [CrossRef]
- Melina, G.; Bruce, P.J.; Vassilicos, J.C. Vortex shedding effects in grid-generated turbulence. Phys. Rev. Fluids 2016, 1, 044402. [Google Scholar] [CrossRef] [Green Version]
- Boulard, T.; Wang, S.; Haxaire, R. Mean and turbulent air flows and microclimatic patterns in an empty greenhouse tunnel. Agric. For. Meteorol. 2000, 100, 169–181. [Google Scholar] [CrossRef]
Dth | φ | φ3D | Lpx | Lpy | Dh | Di | Sp | e |
---|---|---|---|---|---|---|---|---|
13.1 × 30.5 | 39.0 | 75.1 | 164.6 | 593.3 | 165.5 | 167.4 | 0.098 | 391.7 |
Test | Time | uo | θ a | HRo | HRi | To | Ti | Rg |
---|---|---|---|---|---|---|---|---|
12 June 2009 | 10:25–10:55 | 10.28 ± 0.37 | 75 ± 3 | 19 ± 1 | 50 ± 1 | 29.7 ± 0.5 | 26.0 ± 0.4 | 539 ± 28 |
15 June 2009 | 11:00–11:30 | 3.20 ± 0.28 | 98 ± 14 | 32 ± 1 | 72 ± 2 | 32.0 ± 0.4 | 28.6 ± 0.6 | 578 ± 58 |
17 June 2009 | 10:58–11:28 | 5.77 ± 0.55 | 96 ± 7 | 62 ± 1 | 77 ± 1 | 26.6 ± 0.3 | 26.8 ± 0.3 | 486 ± 57 |
18 June2009 | 10:20–10:50 | 5.59 ± 0.56 | 76 ± 5 | 64 ± 1 | 78 ± 2 | 25.8 ± 0.1 | 25.4 ± 0.1 | 295 ± 10 |
Test | u | ui/ue | ux | ux,i/ux,e | uy | uy,i/uy,e | uz | uz,i/uz,e | |
---|---|---|---|---|---|---|---|---|---|
1 | Inside | 2.09 ± 1.21 | 0.39 | 1.11 ± 0.79 | 0.97 | −1.56 ± 1.16 | 0.37 | −0.27 ± 0.33 | 0.13 |
Outside | 5.42 ± 2.53 | 1.15 ± 1.06 | −4.25 ± 2.82 | −2.12 ± 1.65 | |||||
2 | Inside | 0.22 ± 0.13 | 0.17 | 0.04 ± 0.18 | 0.39 | −0.11 ± 0.09 | 0.11 | 0.07 ± 0.04 | −0.27 |
Outside | 1.25 ± 0.87 | 0.10 ± 0.24 | −1.05 ± 0.91 | −0.27 ± 0.48 | |||||
3 | Inside | 0.62 ± 0.46 | 0.26 | 0.29 ± 0.45 | 1.19 | −0.39 ± 0.38 | 0.19 | 0.01 ± 0.12 | −0.02 |
Outside | 2.43 ± 1.52 | 0.24 ± 0.52 | −2.02 ± 1.58 | −0.72 ± 0.90 | |||||
4 | Inside | 1.23 ± 0.66 | 0.34 | 0.73 ± 0.41 | 1.18 | −0.93 ± 0.61 | 0.30 | −0.05 ± 0.12 | 0.05 |
Outside | 3.60 ± 1.66 | 0.62 ± 0.51 | −3.11 ± 1.83 | −1.12 ± 0.88 |
Test | i | ix | iy | iz | k | Ε | |
---|---|---|---|---|---|---|---|
1 | Inside | 0.58 | 0.71 | 0.74 | 1.22 | 1.04 | 1.35 |
Outside | 0.47 | 0.92 | 0.66 | 0.47 | 5.92 | 11.81 | |
2 | Inside | 0.61 | 4.69 | 0.82 | 0.58 | 0.02 | 0.04 |
Outside | 0.69 | 2.38 | 0.86 | 1.77 | 0.56 | 0.98 | |
3 | Inside | 0.74 | 1.56 | 0.97 | 8.29 | 0.18 | 0.31 |
Outside | 0.63 | 2.18 | 0.79 | 1.24 | 1.79 | 3.57 | |
4 | Inside | 0.53 | 0.56 | 0.66 | 2.37 | 0.28 | 0.20 |
Outside | 0.46 | 0.82 | 0.59 | 0.79 | 2.20 | 2.92 |
Test | Li | Lix | Liy | Liz | λ | λx | λy | λz | |
---|---|---|---|---|---|---|---|---|---|
1 | Inside | 3.17 | 1.67 | 2.57 | 5.57 | 0.04 | 0.32 | 0.44 | 0.04 |
Outside | 9.61 | 0.92 | 6.07 | 8.85 | 0.36 | 0.13 | 0.99 | 0.36 | |
2 | Inside | 0.12 | 0.08 | 0.13 | 0.37 | 0.08 | 0.02 | 0.03 | 0.02 |
Outside | 3.36 | 0.10 | 2.48 | 2.32 | 0.43 | 0.01 | 0.34 | 0.06 | |
3 | Inside | 0.52 | 0.47 | 0.47 | 0.15 | 0.24 | 0.13 | 0.08 | 0.00 |
Outside | 2.94 | 0.23 | 2.23 | 2.54 | 0.67 | 0.03 | 0.53 | 0.14 | |
4 | Inside | 2.47 | 1.43 | 2.19 | 2.85 | 0.73 | 0.33 | 0.37 | 0.01 |
Outside | 9.62 | 0.65 | 6.93 | 10.71 | 1.12 | 0.08 | 1.01 | 0.21 |
Test | β | βx | βy | βz | |
---|---|---|---|---|---|
1 | Inside | 1.58 | 1.45 | 1.55 | 1.08 |
Outside | 1.28 | 0.63 | 1.36 | 1.12 | |
2 | Inside | 1.40 | 2.13 | 1.83 | 1.85 |
Outside | 1.37 | 0.59 | 1.55 | 1.33 | |
3 | Inside | 1.53 | 1.82 | 1.59 | 1.31 |
Outside | 1.37 | 0.66 | 1.47 | 1.21 | |
4 | Inside | 1.76 | 1.69 | 1.67 | 1.21 |
Outside | 1.36 | 0.65 | 1.53 | 1.25 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
López-Martínez, A.; Granados-Ortiz, F.-J.; Molina-Aiz, F.D.; Lai, C.-H.; Moreno-Teruel, M.d.l.Á.; Valera-Martínez, D.L. Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse. Agronomy 2022, 12, 586. https://doi.org/10.3390/agronomy12030586
López-Martínez A, Granados-Ortiz F-J, Molina-Aiz FD, Lai C-H, Moreno-Teruel MdlÁ, Valera-Martínez DL. Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse. Agronomy. 2022; 12(3):586. https://doi.org/10.3390/agronomy12030586
Chicago/Turabian StyleLópez-Martínez, Alejandro, Francisco-Javier Granados-Ortiz, Francisco D. Molina-Aiz, Choi-Hong Lai, María de los Ángeles Moreno-Teruel, and Diego L. Valera-Martínez. 2022. "Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse" Agronomy 12, no. 3: 586. https://doi.org/10.3390/agronomy12030586
APA StyleLópez-Martínez, A., Granados-Ortiz, F. -J., Molina-Aiz, F. D., Lai, C. -H., Moreno-Teruel, M. d. l. Á., & Valera-Martínez, D. L. (2022). Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse. Agronomy, 12(3), 586. https://doi.org/10.3390/agronomy12030586