Next Article in Journal
A Novel Algorithm for the Retrieval of Chlorophyll a in Marine Environments Using Deep Learning
Previous Article in Journal
Monitoring Sediment Transport in Certain Harbor Launches in the Southeastern Black Sea
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Study on the Removal Characteristics of IBP and DCF in Wastewater by CW-MFC with Different Co-Substrates

1
School of Life Science and Institute of Wetland Ecology, Nanjing University, Nanjing 210023, China
2
School of Life Science and Basic Medicine, Xinxiang University, Xinxiang 453003, China
3
Nanjing University Ecology Research Institute of Changshu, Changshu 210051, China
4
Ministry of Education’s Key Laboratory of Poyang Lake Wetland and Watershed Research, School of Geography and Environment, Jiangxi Normal University, Ziyang Road 99, Nanchang 330022, China
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Water 2023, 15(21), 3862; https://doi.org/10.3390/w15213862
Submission received: 13 October 2023 / Revised: 25 October 2023 / Accepted: 29 October 2023 / Published: 6 November 2023

Abstract

:
Pharmaceuticals and Personal Care Products (PPCPs) constitute a group of compounds that are challenging to break down and potentially pose risks to both ecosystems and human health when they accumulate in water bodies. This study established and operated small-scale constructed wetland–microbial fuel cells (CW-MFCs) continuously for 60 days, maintaining a hydraulic retention time (HRT) of 3 days. The research aimed to assess the treatment efficiency of wastewater containing Ibuprofen (IBP) and Diclofenac (DCF) using different co-substrates (glucose, sucrose, and sodium acetate) and to analyze the impact of these co-substrates on the composition of bacterial communities within the CW-MFC. After 60 days of operation, CW-MFC achieved removal rates of 89.29% for IBP and 84.10% for DCF. The elimination of IBP was primarily dependent on co-metabolic degradation processes occurring in both the anode and cathode, while DCF removal relied on anodic co-metabolism. Additionally, various co-substrates have an influence on the bacterial community diversity of the anode and cathodes. The possible bacterial groups involved in PPCP degradation were identified. In summary, Glu was identified as a more suitable co-substrate for CW-MFC in the removal of IBP and DCF, while SA as a co-substrate favored the induction and enrichment of EAB in the anodes. These findings offer valuable insights into the potential of CW-MFC for mitigating emerging contaminants.

1. Introduction

Pharmaceutical and personal care products (PPCPs) comprise chemical compounds used for maintaining human health and hygiene, as well as promoting livestock health and growth. PPCPs are extensively utilized in medical, industrial, animal husbandry, aquaculture, and various other domains, intricately interwoven with everyday human life [1,2]. Most pharmaceuticals are not fully metabolized in humans or animals; their metabolites and parent compounds are excreted and enter the sewage system [3,4]. Moreover, inadequately treated medical wastewater can result in the accumulation of PPCPs in natural water bodies [5]. While environmental concentrations of these components typically fall within a low range (a few nanograms to a few micrograms per liter), their toxicity and persistence result in bioconcentration in aquatic organisms, leading to mutagenic, reproductive, genotoxic, and carcinogenic effects, thus posing a potential risk to human health [6,7]. In recent years, propelled by rapid economic growth, the PPCP production and consumption of China have assumed a leading global position [8]. The main source of PPCP infusion into the environment is through wastewater treatment plants (WWTPs), due to the lack of necessary treatments [9,10]. PPCPs and their metabolites have been detected in numerous aqueous environments, including the presence of IBP and DCF [5,8,11].
IBP is a commonly utilized non-steroidal anti-inflammatory drug (NSAID) known for its antipyretic and analgesic properties, with an annual production of 15,000 metric tons [12]. DCF is another non-steroidal drug used to treat conditions such as pain, dysmenorrhea, ocular inflammation, osteoarthritis, rheumatoid arthritis, ankylosing spondylitis, and actinic keratosis [13]. DCF is administered orally at a daily dosage of 75–150 mg, of which around 15% is excreted unchanged into wastewater treatment systems [14,15], making it a primary source of DCF residues in urban sewage [16]. Owing to the extensive use and continuous release of IBP and DCF, substantial residue levels are often identified in raw wastewater, groundwater, surface water, and treated effluent [17], leading to adverse ecological effects. For example, the previous study found that human ovarian explants exposure to 10–100 μmol L−1 IBP triggered apoptosis and reduced proliferating cells [18]. The environmental presence of DCF is a significant factor contributing to the rapid decline in the population of vultures in Pakistan [19]. Furthermore, instances of adverse human health effects resulting from fish consumption have been reported in Finland, primarily due to the presence of DCF and IBP in bile at concentrations ranging from 29 to 194 μg L−1 [20]. Hence, it is imperative to effectively degrade IBP and DCF residues in the aquatic environment to ensure water safety.
Various technologies have been adopted to remove pollutants from water, such as advanced oxidation, late biological treatment, membrane separation, precipitation, and adsorption [21]. Constructed wetlands (CWs), being a relatively mature wastewater treatment technology, employ a range of physical, chemical, and biological processes to handle various types of wastewater [22,23]. In recent decades, CWs have gained increasing attention due to their ease of design and construction as well as their low operating and maintenance costs [24]. CWs have found widespread application in treating industrial wastewater, municipal domestic wastewater, dairy effluents, and textile dye wastewater [25,26,27,28]. Nevertheless, prolonged operation of CWs can lead to a decline in sewage treatment performance due to internal blockages [29]. Recently, the integration or combination of CWs with other treatment methods has been used to address these limitations, thereby improving the removal efficiency of PPCPs and mitigating environmental risks. CW-MFC, a novel integrated application, combines CWs with Microbial Fuel Cells (MFCs), allowing for concurrent wastewater treatment and energy generation [30,31]. CW-MFC combines the three PPCPS removal methods of traditional physics, chemistry, and biology [32], and also has advantages in reducing adsorption material costs and land use [33]. The introduction of MFC strengthens the performance of the anaerobic zone within the CWs [34], which is beneficial to wastewater treatment and adaptation to low temperature conditions [35]. This technology has been applied to treat wastewater containing PPCPs [36,37].
Microorganisms within CW-MFCs exert a dual influence, contributing not only to the generation of electrical energy but also serving a critical role in the removal of pollutants from wastewater [38]. Generally, microorganisms tend to aggregate in both the anode and cathode regions of the CW-MFC. Electrochemically active bacteria (EAB), capable of electricity generation, are typically more abundant in the anaerobic anode region [32]. EAB can directly metabolize simple organic compounds in wastewater to achieve pollutant removal. Nevertheless, in the case of complexly structured pollutants, they collaborate with non-EAB microorganisms to hydrolyze or ferment these compounds into simpler structures. Microorganisms fulfill an indispensable and pivotal role in the pollutant degradation processes in both CW and CW-MFC systems [39]. Nevertheless, the degradation efficiency of microorganisms towards pollutants is influenced by the operational mode and structure of the CW-MFC. Fluctuations in pollutant concentrations can also lead to different microbial degradation patterns [40,41]. Furthermore, as pollutants accumulate within the CW-MFC, the microbial community undergoes a gradual transition toward a composition better suited for pollutant degradation [42]. However, it remains unclear how IBP and DCF impact the microbial community structure within the CW-MFC.
The concentrations of detected PPCPs in natural aquatic environments are relatively low. Despite the variety of PPCP types identified, they are still insufficient to support the growth and metabolic needs of microorganisms [43]. PPCPs need to form synergistic metabolic pathways with other pollutants [44]. Meanwhile, numerous easily degradable small organic compounds can serve as co-substrates for microbial utilization in the removal of PPCPs [45,46,47]. In a study investigating the co-metabolic degradation of the organophosphorus pesticide malathion by Pseudomonas, it was observed that sodium succinate and sodium acetate facilitated both malathion biodegradation and bacterial growth, resulting in an almost complete malathion degradation rate of nearly 100%. In contrast, glucose and fructose exhibited a weak co-metabolism effect, with a malathion degradation rate of less than 30% [48]. In MFC systems, the selection of co-substrate has an influence on both pollutant removal efficiency and power generation performance [49,50,51]. Furthermore, diverse co-substrates can result in varying electron acceptors in CW-MFC systems. For instance, when there are high concentrations of nitrite, nitrate, and oxygen present in the system, the electrons generated by the electricity-producing bacteria may be substantially depleted, leading to a decrease in the electricity generation performance of the CW-MFC [52,53]. Therefore, bench-scale CW-MFCs were employed in this study to investigate the removal characteristics of PPCPs, specifically IBP and DCF, from simulated domestic sewage. We aimed to assess (1) the removal efficiency of IBP and DCF by CW-MFC when utilizing three distinct carbon sources (namely, glucose, succinic acid, and sucrose) as co-substrates; (2) the composition of bacterial communities in the anode and cathode.

2. Methods

2.1. Establishment and Operation of the CW-MFC

Three small-scale CW-MFC devices were built within cylindrical PVC barrels, each with a bottom diameter of 20 cm and a height of 45 cm. Gravel with a diameter of 4–6 mm is used as the bottom layer, and the thickness is 15 cm [54]. On top of this layer, a 5 cm layer of activated carbon particles (with a particle diameter of 2–3 mm) was placed to serve as the anode. A stainless steel mesh was incorporated within the activated carbon to form a stainless steel-activated carbon anode [53]. Above the anode, gravel with a thickness of 20 cm acts as the middle layer. Above the middle layer is the cathode with the same structure as the anode, and the surface of the cathode is exposed to the air. Iris pseudacorus was planted in the cathode area, with three plants in each reactor. Sampling ports were installed at 5 cm intervals along the side of the device, resulting in an effective volume of 3.56 L. The anode and cathode areas were connected via copper wires and connected in series with an external electrical resistor (1000 Ω) (Figure 1). A data acquisition module (DAM-3057, Art Technology Co. Ltd., Beijing, China) was employed for continuous voltage monitoring, with data acquisition occurring at 10-s intervals [55].
The CW-MFC devices were named CM-A, CM-B, and CM-C, employing glucose (Glu), sucrose (Suc), and sodium acetate (SA) as carbon sources, respectively. The carbon source was introduced into the simulated wastewater at a concentration of 300 mg·L−1 (comprising Glu 282.00 mg·L−1, Suc 267.30 mg·L−1, SA 384.00 mg·L−1). For the anode biofilm in this study, activated sludge (MLSS = 17 g·L−1) was collected from the secondary sedimentation tank of the Tangshan WWTP in Nanjing. The composition of other components was as follows: NH4Cl 133.7 mg·L−1, NaH2PO4·2H2O 497 mg·L−1, Na2HPO4·12H2O 75 mg·L−1, KCl 130 mg·L−1, NaHCO3 313 mg·L−1, and MgSO4·7H2O 25 mg·L−1. The devices were covered with tin foil to prevent the formation of microalgae, and all devices and water tanks were kept indoors at a constant room temperature of 25 °C.
During the operation of the system, a hydraulic retention time (HRT) of 3 days was established. The output voltage of the CW-MFC devices was continuously monitored through a data acquisition module. In this study, the electricity generation was stable after 30 days, with the output voltage of the CW-MFC remaining at 480 ± 5 mV. At this point, the target PPCPs, IBP, and DCF were introduced into the simulated wastewater for subsequent experiments.
IBP and DCF (Figure 2), each at a concentration of 10 mg·L−1, were introduced into the simulated wastewater, and the HRT was set at 3 days. The systems operated continuously for 60 days. The target PPCPs, IBP, and DCF (all > 98% purity) used in this study were sourced from Aladdin (Shanghai, China). Properties of the target PPCPs can be found in Table S1.

2.2. Water Sampling and Analysis

Triplicate samples were collected from the sampling points 1, 4, 5, and the effluent, as depicted in Figure 1, every 10 days. The concentrations of COD, total nitrogen (TN), ammonium (NH4+-N), and total phosphorus (TP) in the collected samples were analyzed by the methodology reported by [56]. Furthermore, the concentrations of PPCPs were measured using high-performance liquid chromatography (HPLC) (waters 2695, USA) with a C18 reversed-phase column Diamonsil C18(2) (250 × 4.6 mm, 5 μm). For IBP, the mobile phase consisted of acetonitrile and a 0.1 mol·L−1 potassium dihydrogen phosphate aqueous solution (pH 4.0) with an isocratic elution ratio of acetonitrile to the aqueous solution of 63:37, and the detection wavelength was 263 nm, the flow rate was maintained at 1.0 mL·min−1, and the column temperature was 30 °C. Each sample injection volume was 10 μL. For DCF, a mobile phase of 4% glacial acetic acid and methanol was used with an isocratic elution ratio of 4% glacial acetic acid to methanol at 30:70, and the detection wavelength was 276 nm, the flow rate was 1.0 mL·min−1, the column temperature was 30 °C, and the sample volume was 20 μL. The standard curves for IBP and DCF are shown in Figure S1.
The power density curve and the polarization curve were employed to assess the electrical characteristics of CW-MFCs. The anode coulombic efficiency (CE) was calculated as follows [57]:
C E = I F × q × n × C O D
I is the current (A), F is the Faraday constant (96485 C/mol e), 32 is the molar mass of O2, 4 is the electron number gained by the reduction reaction of 1 molar O2, q is volumetric influent flow rate of CW-MFCs (L/s), and COD is the difference of COD between the influent and the effluent of the anode.

2.3. Substrate Sampling and Bacterial Community Analysis

The activated carbon from the anode and cathode of the CW-MFC devices were sampled at the conclusion of the experiment. The E.Z.N.A.® soil DNA kit (Omega Bio-tek, Norcross, GA, USA) was used to extract the total DNA. The forward primer (5′-GTGCCAGCMGCCGCGG-3′) and reverse primer (5′-CCGTCAATTCMTTTRAGTTT-3′) were used to amplify the V4 and V5 regions of the bacterial 16S rRNA gene. The PCR protocol followed the method reported by [58]. After the amplicons were purified and quantified, high-throughput sequencing was conducted via the Illumina Miseq PE300 platform (Majorbio Bio-pharm Technology Co., Ltd., Shanghai, China). A representative sequence from each operational taxonomic unit (OTU) (sequence similarity was over 97%) was classified and assigned to a phylum, class, and genus level. Subsequently, alpha diversity indices, such as Shannon, Simpson, Ace, and Coverage, were calculated to assess the variations in the diversity and richness of bacterial communities within the devices.

2.4. Statistical Analysis

SPSS 24.0 (IBM SPSS Inc., Chicago, IL, USA) was used for statistical data analysis, and one-way analysis of variance (ANOVA) was used to analyze the differences in bacterial diversities. The IBP and DCF removal amounts between groups were compared using one-way ANOVA (p < 0.05) followed by Duncan’s multiple range tests.

3. Results

3.1. PPCP Removal with Different Co-Substrates

The average IBP concentrations at sampling port 4 were 8.10 ± 0.04 mg L−1 in devices of CM-A, 7.93 ± 0.07 mg L−1 in devices of CM-C, and 8.36 ± 0.03 mg L−1 in devices of CM-B (Table 1). Meanwhile, the mean values of the IBP concentrations at sampling port 5 were 2.96 ± 0.03 mg L−1 in devices of CM-A, 2.21 ± 0.05 mg L−1 in devices of CM-C, and 2.71 ± 0.02 mg L−1 in devices of CM-B (Table 1). The IBP concentrations at sampling ports 4 and 5 in devices of various carbon sources were observably different (p < 0.05; Table 1). Additionally, 2.68 ± 0.04 mg L−1, 2.13 ± 0.08 mg L−1, and 2.63 ± 0.02 mg L−1 were observed at sampling port 10 in devices of CM-A, CM-C, and CM-B, respectively (Table 1). The IBP concentrations at sampling port 10 in devices of CM-C were significantly lower than those in devices of CM-A and CM-B (p < 0.05; Table 1).
Additionally, the IBP concentrations in the final effluent liquid were 1.56 ± 0.03 mg L−1, 1.64 ± 0.03 mg L−1, and 1.57 ± 0.03 mg L−1 in devices of CM-A, CM-C, and CM-B, respectively (Table 1). The IBP concentrations of the final effluent liquid in devices of various carbon sources were markedly different (p < 0.05), indicating that the total IBP removal was highest in devices of CM-A and lowest in devices of CM-C (Table 1).
The average DCF concentrations at sampling port 4 were 6.53 ± 0.13 mg L−1 in devices of CM-A, 5.85 ± 0.09 mg L−1 in devices of CM-C, and 6.19 ± 0.01 mg L−1 in devices of CM-B (Table 2). Notably, there were significant differences in DCF concentrations at sampling port 4 among devices with varying carbon sources (p < 0.05; Table 2). At sampling port 5, the DCF concentrations were 2.67 ± 0.18 mg L−1 in devices of CM-A, 2.47 ± 0.09 mg L−1 in devices of CM-C, and 2.35 ± 0.06 mg L−1 in devices of CM-B, while at sampling port 10, they were 1.82 ± 0.03 mg L−1 in devices of CM-A, 1.71 ± 0.02 mg L−1 in devices of CM-C, and 1.69 ± 0.03 mg L−1 in devices of CM-B (Table 2). In both sampling ports 5 and 10, DCF concentrations in devices of CM-A were significantly higher compared to those in devices of CM-C and CM-B (p < 0.05; Table 2).

3.2. Bacterial Community Analysis

Bacterial community relative abundances and diversity index values were compared for various co-substrate combinations (Table 3). The coverage value of each sample exceeded 0.98. However, when SA was used as a co-substrate, the OTU numbers, alpha diversity, and uniformity were found to be significantly lower (p < 0.05, Table 3).
In IBP-Glu (Figure 3A), the anode exhibits an enrichment of bacteria from four major groups, namely Chloroflexi (the class of Anaerolineae), Verrucomicrobiota (including the classes Lentisphaeria and Omnitrophia), Bacteroidota (from phylum to class), and unclassified phyla (from phylum to class). In contrast, the cathode is enriched with bacteria from the Proteobacteria (including the classes Alphaproteobacteria and Gammaproteobacteria), FW113 (from phylum to class), and the class Actinobacteria. In IBP-Suc (Figure 3B), the anode is predominantly enriched with Chloroflexi (from phylum to class), specifically the class Anaerolineae (within the phylum Chloroflexi), Bacteroidota (from phylum to class), Desulfobacterota, Actinobacteriota, Verrucomicrobiota, and Firmicutes. Interestingly, the IBP-Suc cathode does not exhibit enrichment of FW113, and its community composition mirrors that of IBP-Glu (Figure 3A). In IBP-SA (Figure 3C), the anode is still dominantly occupied by Chloroflexi (from phylum to class) and the class Anaerolineae (within the phylum Chloroflexi). Additionally, Spirochaetota (from phylum to class) is enriched for the first time, while Acidobacteriota is only enriched at the phylum level. Notably, in the IBP-SA (Figure 3C) cathode, a significant enrichment of Alphaproteobacteria (within the Proteobacteria phylum) is observed, along with Actinobacteriota (from phylum to class), Planctomycetota (from phylum to class), and the class Bacilli.
Figure 3D represents the bacterial composition of the CW-MFC anode and cathode in the DCF-Glu anode, and there is a higher occurrence of Bacteroidota (from phylum to class), along with enrichments of Chloroflexi (from phylum to class) and Verrucomicrobiota (from phylum to class). In the cathode, there remains a notable abundance of Alphaproteobacteria (within the Proteobacteria phylum), alongside enrichments of Actinobacteriota (from phylum to class) and the Planctomycetota phylum. Moving to DCF-Suc (Figure 3E), the anode is enriched with Bacteroidota (from phylum to class), Omnitrophia (within Verrucomicrobiota), and Desulfobacterota at the phylum level. In the cathode of DCF-Suc, Proteobacteria (including the classes Alphaproteobacteria and Gammaproteobacteria) are predominant, which is similar to the patterns observed in IBP-Glu (Figure 3A) and IBP-Suc (Figure 3B). However, the DCF-Suc cathode exhibits a higher proportion of Planctomycetota (from phylum to class) compared to the IBP groups. In DCF-SA (Figure 3F), the anode is enriched with a significant abundance of Gammaproteobacteria (within the phylum Proteobacteria), Chloroflexi (from phylum to class), and Anaerolineae (within the phylum Chloroflexi). It is worth noting that the phylum Firestonebacteria is enriched in DCF-SA. On the cathode side, Proteobacteria (including the class Alphaproteobacteria), Actinobacteriota (from phylum to class), and the class Bacilli are detected and found to be enriched.
LEfSe analysis was employed to discriminate the indicator microbial communities at various taxonomic levels, ranging from domain to class in the cathodes and anodes of three CW-MFC devices (CM-A, CM-B, and CM-C) during the removal of IBP and DCF. The selection criteria were based on an LDA score exceeding 4. In the anode treated with IBP (Figure 4A), Bacteroidota (from phylum to class) is enriched in CM-A. CM-B displays an enrichment of the class Bacilli (within the phylum Firmicutes), while CM-C shows a high abundance of the phylum Spirochaetota. When removing DCF, in the cathode (Figure 4B), the class Alphaproteobacteria (within phylum Proteobacteria) is enriched in CM-C. CM-B demonstrates a higher abundance of the class Desulfobaccia (within the phylum Desulfobacterota) and the class Chlorobia (within the phylum Bacteroidota). In the anode (Figure 4C), Bacteroidota (from phylum to class) is enriched in CM-A. CM-B exhibits an enrichment of the class RBG-16-55-12 (within the phylum Actinobacteriota), and the phylum Patescibacteria is also enriched.
Figure 5A,B illustrates the differences in cathodic and anodic bacterial communities among the devices of CM-A, CM-B, and CM-C when IBP is removed. PCoA analysis indicates that the influence of the co-substrates on the cathodic bacterial community is not significant. (ANOSIM, p = 0.8400, Figure 5A). However, significant differences emerge in the anodic bacterial community (ANOSIM, p = 0.0110, Figure 5B). Furthermore, when dealing with the contaminant DCF, the co-substrates significantly affect the bacterial community structure in both the cathode (ANOSIM, p = 0.0330, Figure 5C) and the anode (ANOSIM, p = 0.0200, Figure 5D) of the CW-MFC.
During the IBP removal process by CW-MFC, at the family level, environmental variables (Glu, Suc, SA, NH4+-N, TN, and TP) explained 73.91% and 85.67% of the total changes in bacterial community composition at the cathode (Figure 6A) and anode (Figure 6B), respectively. In the anode, environmental variables significantly influence changes in the bacterial community (p < 0.05). Among the top five species in terms of abundance in the anode, the abundance of the family Moraxellaceae is positively correlated with the concentration of SA, while the abundance of the family Weeksellaceae is positively correlated with the concentration of Glu (Figure 6B).
Figure 6C,D illustrates the effects of environmental variables (Glu, Suc, SA, NH4+-N, TN, and TP) at the class level on the composition of bacterial communities in the cathode and anode during DCF removal in CW-MFC. The explainability of environmental factors on the changes in the bacterial community composition in the cathode and anode is 90.88% and 89.40%. In the cathode, changes at the class level were closely associated with Suc (p = 0.06, Figure 6C). In the anode, aside from TP, the other five environmental variables significantly influence the bacterial community at the class level (Figure 6D).
The correlation analysis of environmental variables (COD, NH4+-N, TN, TP, IBP, and DCF) with the bacterial community in CW-MFC cathodes at the phylum level (Figure 7A) indicates significant negative correlations. Specifically, the abundance of Cyanobacteria, Firmicutes, and Actinobacteriota is significantly negatively correlated with COD concentration. The abundance of Verrucomicrobiota is significantly negatively correlated with NH4+-N concentration, while the abundance of Patescibacteria exhibits significantly negative correlation with NH4+-N, TN, and TP concentrations. The correlation analysis of environmental factors with the bacterial community at the phylum level in the anodes (Figure 7B) reveals several significant correlations. Campilobacterota, Firmicutes, Bdellovibrionota, Patescibacteria, and Desulfobacterota exhibit significant positive correlations with NH4+-N concentration. Conversely, Campilobacterota and Firmicutes are significantly negatively correlated with TP concentration. In addition, the abundance of Actinobacteriota and Bacteroidota is also significantly negatively correlated with TP concentration. It is worth noting that among the top 20 most abundant bacteria in the anode, only the abundance of Proteobacteria is significantly positively correlated with TP. IBP concentration is positively correlated with the abundance of most anode bacteria, including significant correlations with Armatimonadota and Chloroflexi.
Figure 7 presents a correlation heatmap illustrating the relationships between cathode and anode bacterial communities at the phylum level with environmental variables (Glu, Suc, SA, NH4+-N, TN, and TP) after PPCPs treatment. In the cathode bacterial community treated with IBP (Figure 7A), the abundance of Gemmatimonadota and Verrucomicrobiota are significantly positively correlated with Glu concentration, while the abundance of Gemmatimonadota is significantly negatively correlated with Suc concentration (Figure 7A). Additionally, the phylum Actinobacteriota shows a negative correlation with Suc concentration (Figure 7A). In the anode community treated with IBP (Figure 7B), several significant correlations are identified. The abundances of Campilobacterota, Armatimonadota, Patescibacteria, Firmicutes, Planctomycetota, and Actinobacteriota are positively correlated with Suc concentration. SA concentration shows positive correlations with the abundances of Spirochaetota and Nitrospirota but is negatively correlated with Firmicutes and Actinobacteriota. Glu concentration is only significantly positively correlated with Bacteroidota, while the abundance of Bacteroidota is negatively correlated with TN and TP concentrations (Figure 7B).
In the cathode bacterial community after DCF treatment (Figure 7C), the phylum Actinobacteriota is significantly positively correlated with Glu but is negatively correlated with NH4+-N concentration. The abundance of Gemmatimonadota is negatively correlated with SA, NH4+-N, TN, and TP concentrations, while it exhibits a positive correlation with Glu, although not significantly (Figure 7C). In the anode community after DCF treatment (Figure 7D), the abundance of Elusimicrobiota phylum is positively correlated with NH4+-N and Suc concentrations. Ten phyla, including Myxococcota and Armatimonadota, are significantly negatively correlated with SA concentration, while the abundance of Proteobacteria is significantly positively correlated with SA concentration. Additionally, the abundance of Patescibacteria phylum is significantly positively correlated with Suc and NH4+-N concentrations (Figure 7D).

3.3. Nutrient Removal with Different Carbon Sources

After continuous operation for 60 days, the removal of COD, NH4+-N, TN, and TP in devices of CM-A, CM-B, and CM-C is depicted in Table 4. At sampling port 4, the COD concentration in CM-C was 119.10 ± 0.70 mg L−1, significantly differing from CM-A (175.40 ± 2.29 mg L−1) and CM-B (170.70 ± 2.29 mg L−1) (p < 0.05; Table 4). Conversely, at sampling port 5, sampling port 10, and the effluent, significantly higher COD detection concentrations were observed in CM-B compared to the other two groups of devices (p < 0.05; Table 4). In the end, the device of CM-A exhibited the highest average COD removal amount, removing 280.06 ± 6.98 mg L−1 of COD. Following that, CM-C removed 274.73 ± 2.27 mg L−1 of COD, while CM-B displayed the lowest COD removal of only 256.54 ± 1.73 mg L−1 (with the initial concentration of COD being 300 mg L−1).
At sampling port 4, the concentration of NH4+-N in CM-C was the lowest at 18.99 ± 0.12 mg L−1, whereas CM-A displayed the highest detected concentration at this location, which was 23.61 ± 0.01 mg L−1 (p < 0.05; Table 4). However, at sampling port 5 and sampling port 10, the highest concentration of NH4+-N was observed in CM-B (p < 0.05; Table 4). In the final effluent, the highest concentration was observed in the device of CM-C, at 14.46 ± 0.10 mg L−1 (p < 0.05; Table 4). On average, the devices of CM-A exhibited the highest NH4+-N removal of 25.20 ± 0.06 mg L−1, significantly higher than that in CM-B (21.68 ± 0.06 mg L−1) and CM-C (20.34 ± 0.10 mg L−1) (p < 0.05; Table 4) (with the initial concentration of NH4+-N was34.8 mg L−1).
At sampling port 4, the TN concentration in CM-C was the lowest, measuring 18.22 ± 0.11 mg L−1. Conversely, CM-B recorded the highest detected concentration at 22.04 ± 0.07 mg L−1, while CM-A showed a TN concentration of 21.16 ± 0.01 mg L−1 (p < 0.05; Table 4). At sampling ports 5 and 10, the highest TN concentrations were consistently observed in the device of CM-B (p < 0.05; Table 4). However, in the effluent, the highest TN concentration was noted in the device of CM-C, at 10.65 ± 0.04 mg L−1 (p < 0.05; Table 4). On average, CM-A achieved the highest TN removal, measuring 30.93 ± 0.19 mg L−1, significantly surpassing the TN removal amount in CM-B (25.16 ± 0.00 mg L−1) and CM-C (24.15 ± 0.04 mg L−1) (p < 0.05; Table 4) (with an initial TN concentration of 34.8 mg L−1).
At sampling port 4, CM-A exhibited the lowest average TP concentration at 273.09 ± 0.30 mg L−1, while CM-B had a concentration of 274.86 ± 0.33 mg L−1 and CM-C showed the highest average TP concentration, reaching 293.00 ± 0.30 mg L−1 (Table 4). Significant differences in TP concentrations were observed among these devices (p < 0.05). It is noteworthy that the relative magnitudes and differences in average TP concentrations among the three devices remained consistent at sampling ports 5 and 10 and the effluent. Consequently, devices of CM-A achieved the highest average TP removal, of 227.93 ± 0.39 mg L−1, followed by CM-B, with 212.05 ± 0.63 mg L−1, while CM-C had the lowest average TP removal, at only 162.42 ± 1.32 mg L−1 (p < 0.05; Table 4) (with an initial TP concentration of 376 mg L−1).

3.4. The Electrical Characteristics of CW-MFCs

Figure 8 and Figure 9 display DO variation over height in CW-MFC and the polarization and power density curves of the CW-MFC under the influence of different carbon sources. The polarization curves on the left axis all exhibit good fits, indicating stable electricity generation performance for the CW-MFC devices using the three different carbon sources. The highest point on the power density curve on the right axis represents the maximum power density, denoted as Pmax. In this study, the CW-MFC with Glu as the carbon source exhibited a Pmax (maximum power output) of 75.50 mW/m3, significantly higher than that of CW-MFCs with SA or Suc as the co-substrates.

4. Discussion

4.1. Effects of Different Co-Substrates on PPCP Removal

When Glu is used as a co-substrate, the total removal of IBP is significantly higher compared to Suc and SA as co-substrates. Specifically, in the CM-A anode region (between sampling points 4 and 5), the removal rate of IBP is notably higher than in the bottom layer (between influent and sampling point 4), middle layer (between sampling points 5 and 10), and the cathode layer (between sampling point 10 and effluent) (Table 1). Similar observations are also made in CM-B and CM-C. Regarding the removal of DCF, when Glu and Suc are used as co-substrates, the CW-MFC significantly removes a higher total amount of DCF compared to SA as the co-substrate. Primary removal of DCF predominantly occurs in the anode and the bottom layer, with significant differences observed among various co-substrates (p < 0.05, Table 2). It is evident that CW-MFC’s efficiency in removing both IBP and DCF is closely associated with the anode, which exhibits higher microbial biomass and diversity compared to the cathode (Table 3). These findings align with numerous research results highlighting the pivotal role of microorganisms enriched in the anode in the transformation and utilization of PPCPs [59,60]. In this study, the bottom layer and middle layer show relatively high removal rates for DCF. However, different co-substrates do not significantly affect the removal of DCF in the middle layer (p > 0.05, Table S2). The composition of the middle layer is gravel, with a volume of 6.28 L. Gravel is a common material for CW and CW-MFC construction. Some researchers used the gravel bed CW to remove ten types of PPCPs and identified the presence of 4-hydroxy-diclofenac in the pore water and effluent [54], which is a common transformation product of DCF in wastewater [61]. This suggests that biodegradation in CW pore water is also one of the removal pathways for DCF. However, the transformation of DCF in CW-MFC still needs more research. Overall, the CW-MFC device constructed in this study exhibits relatively good removal performance for both IBP and DCF (Table 1 and Table 2), surpassing the results reported in previous research studies [31]. Both Glu and Suc as co-substrates outperform SA in PPCP removal. In CM-C, the Sobs and Shannon indices in the cathode and anode are significantly lower than in CM-A and CM-B (Table 3). SA has a smaller molecular weight (82.03) and a simpler structure, which results in faster consumption in the bottom and anode layers, leading to a carbon source deficiency in the cathode. This explains why the CM-C device has lower PPCP concentrations at sampling port 4, which is closest to the influent, but the lowest overall PPCP removal.

4.2. Effects of Different Co-Substrates on Bacterial Community

The electrodes are considered the primary locations for microbial enrichment and hold significant importance in the CW-MFC system for both pollutant removal and electricity generation [31,62,63]. In this study, phyla such as Firmicutes, Actinobacteria, and Acidobacteria (Figure 3) found in the anode have been identified as EAB [64]. These bacteria not only participate in electricity generation but are also believed to play a crucial role in enhancing the diversity of the bacterial community (Figure 4) [65,66]. Furthermore, in the study, when Glu and Sucrose Suc were co-metabolized with the two PPCPs, both resulted in an enrichment of Bacteroidota in the anodic bacterial community (Figure 3A,B,D,E). However, this dominance was not observed with DCF-SA (Figure 3F). Bacteroidota is a dominant group in anaerobic granular sludge (AGS) [67], suggesting that their source may be seeded AGS. This phenomenon suggests that the simulated wastewater used in this study had an appropriate organic concentration, meeting the metabolic activity requirements of the seeded AGS. In the case of the DCF-SA combination, SA was used for electricity generation, resulting in insufficient organic concentration at the anode. Likewise, the enrichment of Planctomycetota was observed in the cathodes of various co-substrate combinations (Figure 3), but it was somewhat inhibited in the DCF-SA cathode (Figure 3F). Planctomycetota are involved in various biogeochemical cycles in river ecosystems, encompassing element redox reactions, pollutant degradation, nitrogen cycling, and carbon utilization [68]. This observation may account for the lower removal rate of TN by DCF (Table 4).
In this study, the choice of co-substrate significantly influences the bacterial community composition in the CW-MFC anode during IBP treatment, while it does not significantly affect the cathode bacterial composition (Figure 5A). Additionally, the family Weeksellaceae (within the phylum Bacteroidota) in the anode, after IBP treatment, is significantly positively correlated with the concentration of Glu (Figure 6B and Figure 7B), yet it is absent in the cathode. The genus Chryseobacterium, which falls within the family Weeksellaceae, is known to be involved in the degradation of various exogenous drugs, including fungicides like Mancozeb [69] and herbicides [70]. This suggests that the Weeksellaceae family may be responsible for the primary biodegradation of IBP. Furthermore, in the IBP-treated anode, the family Moraxellaceae demonstrates a significant positive correlation with SA concentration (Figure 6B). Moraxellaceae, a family of Gammaproteobacteria, includes the genus Moraxella, which is known for its ability to thrive using unstable compounds, particularly dissolved organic matter [71]. Moreover, Gammaproteobacteria are commonly employed as EAB in MFC systems [72]. In the IBP-treated anode, Suc is positively correlated with Anaerolineaceae (Figure 6B), which belongs to the Chloroflexi phylum. Microorganisms within the Anaerolineaceae family are often associated with anaerobic ammonia oxidation processes, suggesting their capacity to utilize organic carbon generated from cell lysis for growth [73,74]. Furthermore, in the IBP-treated anode, the correlation of Suc and NH4+-N with various bacteria is consistent (Figure 7B). This suggests that Suc, compared to Glu, is less readily metabolized by microorganisms, allowing it to be more involved in anaerobic ammonia oxidation processes [75].
The choice of co-substrate significantly influences both the cathode and anode bacterial communities during DCF treatment (Figure 5C,D). In the cathode bacterial community during DCF treatment, the variation is primarily dependent on Suc concentration (Figure 6C). This can be attributed to the fact that Suc needs to undergo hydrolyzation before it becomes accessible for microbial utilization, rendering it more likely to be a source of carbon for cathode bacteria.
In the cathode bacterial community during DCF treatment, Patescibacteria, Planctomycetota, and Chloroflexi are significantly positively correlated with Suc concentration (Figure 4C and Figure 7C). Chloroflexi and Planctomycetes are known for their potential involvement in the removal of PPCPs [76]. While the gravel fillers in the device possess some adsorption capacity for DCF, as the experiment progresses and the adsorption reaches saturation, the concentration of DCF not degraded by anodic bacteria gradually increases and flows toward the cathode. This could provide an opportunity for the enrichment of Chloroflexi and Planctomycetes in the cathode (Figure 7C). Previous research has shown that the addition of PPCPs to bioreactors can promote the dominance of Proteobacteria [77]. This may explain the phenomenon in Figure 7D, where SA is significantly positively correlated only with the Proteobacteria phylum. The easily utilizable SA co-substrate is rapidly consumed by Proteobacteria upon entering the anode during DCF treatment, further contributing to its dominance.

4.3. Effect of Different Co-Substrates on the CW-MFC Performance

The COD removal rate in CW-MFC is influenced by various factors, including device configuration, initial COD concentration, HRT, wastewater characteristics, and bacterial communities [78]. In this study, the COD removal rate in CW-MFC exceeded that reported in previous research with similar configurations [79,80]. Previous studies have suggested that the higher COD removal rate of CW-MFC compared to CWs is due to the introduction of electrodes and conductive materials. Conductive materials can use themselves as temporary electron acceptors to accelerate the anaerobic oxidation process of pollutants [81]. Higher bacterial community diversity in the anode also promotes COD removal (Table 3). For example, GAC, the electrode material in this study, possesses the capability to extract electrons from organic compounds, enhancing the attachment of bacteria to GAC particles within the anode layer [82]. In addition, the COD adsorption behaviors of gravel cannot be ignored. Depending on the initial concentration and loading amount, the COD removal efficiency of gravel is in the range of 18.76~38.15% [83].
The removal of NH4+-N in CW-MFC systems is believed to primarily depend on nitrification in the presence of oxygen. Therefore, the residual carbon source content available to drive the nitrification reaction in the cathode and the cathode’s structure characteristics are critical factors in the nitrogen removal in CW-MFC [84]. In this study, the DO concentration is depicted in Figure 8, showing that the DO brought in with the influent and cathode is higher than other locations of the system. The removal patterns for NH4+-N and TN also exhibit higher removal rates in the bottom layer and cathode in comparison to other layers. As SA is the most readily decomposed carbon source, it supplies the smallest amount of carbon at the cathode, resulting in the lowest removal rates for NH4+-N and TN in CW-MFC when SA is used as the carbon source. These findings are consistent with previous research [85]. However, some researchers believe that the overall effective denitrification performance in CW-MFC is mainly attributed to the diverse bacterial communities and the presence of abundant electroactive bacteria, which contribute to enhancing the rates of anaerobic ammonium oxidation, nitrification, and denitrification processes within CW-MFC [31,66,86].
Regarding the removal of TP, Glu is a more suitable carbon source compared to SA and Suc. TP removal is the greatest (Table 4), and the removal rate is 60.62%, lower than reported in previous research [87,88]. Typically, phosphorus compounds are removed in CW-MFC through biological or physicochemical processes. Some researchers argue that physicochemical processes play a more substantial role in TP removal than biological processes [38,89]. We found that only the bacterial community composition in the IBP-treated anode was significantly affected by TP concentration, and biodegradation made a limited contribution to TP removal (Figure 6). Some researchers have even observed unexplained reductions in TP removal rates in conventional CWs coupled with MFC [90]. Therefore, further research on plant species, system configuration, and microbial communities is essential to enhance our comprehension of the elements influencing reduced rates of TP removal.
SA is typically recognized as a carbon source that stimulates the proliferation of electroactive bacteria (Figure 6) [49]. However, in this study, when SA was used as the co-substrate, the CW-MFC exhibited the lowest output voltage and device power density, while the Glu co-substrate showed the best electricity generation performance (Figure 9), which is similar to findings reported in previous studies [57,91]. This difference can be attributed to the fact that Glu participates more rapidly in the electricity-producing process compared to SA, generating higher electrical energy in a shorter time. However, over prolonged operation, SA as the co-substrate might lead to a decrease in microbial diversity within the CW-MFC [92]. Additionally, the SA co-substrate undergoes electrochemical reactions that generate acids under anaerobic conditions. This acid production reduces the pH of the anode environment and inhibits the activity of anaerobic microorganisms, consequently reducing the system’s electricity generation performance [93]. On the other hand, the Glu co-substrate may result in electron competition among bacteria. Nevertheless, a more diverse bacterial composition is advantageous for the degradation of complex substrates [94].
This study focuses on how different carbon sources affect the co-metabolic removal of PPCPs, therefore maintaining a relatively conservative approach to device design, electrode selection, and operating conditions of the CW-MFC system. In the future, more research is needed for more efficient removal of PPCPs from wastewater by CW-MFC. For instance, optimizing the HRT can potentially achieve IBP removal rates exceeding 95% due to its simple structure [31]. Additionally, exploring the utilization of new functional complexes with enhanced PPCP adsorption capabilities as electrodes or additives could significantly improve pollutant removal efficiency. Moreover, the potential application of CW-MFC as a biosensor within the CW environment holds promise for various environmental monitoring purposes [95,96].

5. Conclusions

In this study, the CW-MFC achieved high removal efficiencies of 89.29% for IBP and 84.10% for DCF, with Glu as the most effective co-substrate for PPCP removal and electricity generation. The co-metabolism of IBP and a carbon source took place in both the anode and cathode of the CW-MFC, while the co-metabolism of DCF and a carbon source primarily occurred at the anode. Furthermore, the composition of the bacterial community in the anode of IBP-treated CW-MFC was influenced by the choice of co-substrates. In contrast, the composition of the bacterial community in both the cathode and anode of DCF-treated CW-MFC was influenced by the co-substrate used. Analysis of the electrode microbial community structure revealed that the presence of SA as a co-substrate favored the induction and enrichment of EAB in the anodes within the CW-MFC. In conclusion, it is evident that CW-MFC holds significant research potential in power generation and has the capacity for larger-scale applications.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/w15213862/s1, Figure S1: The standard curves for IBP and DCF; Table S1: Target PPCPs used in this study and their properties; Table S2: DCF removal rates (%) of each layers.

Author Contributions

G.Q.: Conceptualization, methodology, formal analysis, data curation, writing—original draft. H.F.: formal analysis, methodology, writing—original draft. R.Y., F.Z. and X.J.: resources, investigation. L.X.: supervision, writing—review and editing. S.A.: supervision, conceptualization, resources, project administration, and funding acquisition. All authors have read and agreed to the published version of the manuscript.

Funding

This study was funded by Chaohu Basin Mountains, Waters, Forests, Fields, Lakes and Grassland Monitoring System Construction Project (Survey and Assessment Part) [2022BFAWZ02436], Research and demonstration of bird-friendly constructed wetland technology for treating aquaculture tailwater at heritage sites [HSDKT202310] and The Major Science and Technology Program for Water Pollution Control and Treatment of China [2017ZX07401003-02].

Data Availability Statement

The data are available from the corresponding author upon reasonable request.

Acknowledgments

We would like to thank Miao Zhang and Jing Chen for their assistance in the maintenance of the systems.

Conflicts of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. Ordóñez, C.; Pamela, D. Determination of HPLC/MS/MS Capabilities for the Monitoring of Trace Level Pharmaceuticals and Personal Care Products (PPCP) in Environmental Samples; California State University: Fresno, CA, USA, 2015. [Google Scholar]
  2. Daughton, C.G.; Ternes, T.A. Pharmaceuticals and personal care products in the environment: Agents of subtle change? Env. Health Perspect 1999, 107 (Suppl. 6), 907–938. [Google Scholar] [CrossRef] [PubMed]
  3. Guruge, K.S.; Goswami, P.; Tanoue, R.; Nomiyama, K.; Wijesekara, R.G.S.; Dharmaratne, T.S. First nationwide investigation and environmental risk assessment of 72 pharmaceuticals and personal care products from Sri Lankan surface waterways. Sci. Total Environ. 2019, 690, 683–695. [Google Scholar] [CrossRef] [PubMed]
  4. Ren, B.; Shi, X.; Jin, X.; Wang, X.C.; Jin, P. Comprehensive evaluation of pharmaceuticals and personal care products (PPCPs) in urban sewers: Degradation, intermediate products and environmental risk. Chem. Eng. J. 2021, 404, 127024. [Google Scholar] [CrossRef]
  5. Yang, H.; Lu, G.; Yan, Z.; Liu, J.; Dong, H.; Jiang, R.; Zhou, R.; Zhang, P.; Sun, Y.; Nkoom, M. Occurrence, spatial-temporal distribution and ecological risks of pharmaceuticals and personal care products response to water diversion across the rivers in Nanjing, China. Environ. Pollut. 2019, 255, 113132. [Google Scholar] [CrossRef] [PubMed]
  6. Menger, F.; Ahrens, L.; Wiberg, K.; Gago-Ferrero, P. Suspect screening based on market data of polar halogenated micropollutants in river water affected by wastewater. J. Hazard. Mater. 2021, 401, 123377. [Google Scholar] [CrossRef] [PubMed]
  7. Rainsford, K.D. Ibuprofen: Pharmacology, efficacy and safety. Inflammopharmacology 2009, 17, 275–342. [Google Scholar] [CrossRef]
  8. Zhao, J.-L.; Ying, G.-G.; Wang, L.; Yang, J.-F.; Yang, X.-B.; Yang, L.-H.; Li, X. Determination of phenolic endocrine disrupting chemicals and acidic pharmaceuticals in surface water of the Pearl Rivers in South China by gas chromatography–negative chemical ionization–mass spectrometry. Sci. Total Environ. 2009, 407, 962–974. [Google Scholar] [CrossRef]
  9. Bu, Q.W.; Wang, B.; Huang, J.; Deng, S.B.; Yu, G. Pharmaceuticals and personal care products in the aquatic environment in China: A review. J. Hazard. Mater. 2013, 262, 189–211. [Google Scholar] [CrossRef]
  10. Evgenidou, E.N.; Konstantinou, I.K.; Lambropoulou, D.A. Occurrence and removal of transformation products of PPCPs and illicit drugs in wastewaters: A review. Sci. Total Environ. 2015, 505, 905–926. [Google Scholar] [CrossRef]
  11. Mei, X.; Sui, Q.; Lyu, S.; Wang, D.; Zhao, W. Pharmaceuticals and personal care products in the urban river across the megacity Shanghai: Occurrence, source apportionment and a snapshot of influence of rainfall. J. Hazard. Mater. 2018, 359, 429–436. [Google Scholar] [CrossRef]
  12. Jia, Y.; Yin, L.; Khanal, S.K.; Zhang, H.; Oberoi, A.S.; Lu, H. Biotransformation of ibuprofen in biological sludge systems: Investigation of performance and mechanisms. Water Res. 2020, 170, 115303. [Google Scholar] [CrossRef] [PubMed]
  13. Al-Qaim, F.F.; Abdullah, M.P.; Othman, M.R.; Latip, J.; Zakaria, Z. Multi-residue analytical methodology-based liquid chromatography-time-of-flight-mass spectrometry for the analysis of pharmaceutical residues in surface water and effluents from sewage treatment plants and hospitals. J. Chromatogr. A 2014, 1345, 139–153. [Google Scholar] [CrossRef] [PubMed]
  14. Zhang, Y.; Geißen, S.-U.; Gal, C. Carbamazepine and diclofenac: Removal in wastewater treatment plants and occurrence in water bodies. Chemosphere 2008, 73, 1151–1161. [Google Scholar] [CrossRef] [PubMed]
  15. Landsdorp, D.; Vree, T.B.; Janssen, T.J.; Guelen, P.J. Pharmacokinetics of rectal diclofenac and its hydroxy metabolites in man. Int. J. Clin. Pharmacol. Ther. Toxicol. 1990, 28, 298–302. [Google Scholar]
  16. Heberer, T.; Feldmann, D. Contribution of effluents from hospitals and private households to the total loads of diclofenac and carbamazepine in municipal sewage effluents—modeling versus measurements. J. Hazard. Mater. 2005, 122, 211–218. [Google Scholar] [CrossRef]
  17. Minella, M.; Bertinetti, S.; Hanna, K.; Minero, C.; Vione, D. Degradation of ibuprofen and phenol with a Fenton-like process triggered by zero-valent iron (ZVI-Fenton). Environ. Res. 2019, 179, 108750. [Google Scholar] [CrossRef]
  18. Leverrier-Penna, S.; Mitchell, R.T.; Becker, E.; Lecante, L.; Ben Maamar, M.; Homer, N.; Lavoué, V.; Kristensen, D.M.; Dejucq-Rainsford, N.; Jégou, B.; et al. Ibuprofen is deleterious for the development of first trimester human fetal ovary ex vivo. Hum. Reprod. 2018, 33, 482–493. [Google Scholar] [CrossRef]
  19. Oaks, J.L.; Gilbert, M.; Virani, M.Z.; Watson, R.T.; Meteyer, C.U.; Rideout, B.A.; Shivaprasad, H.L.; Ahmed, S.; Iqbal Chaudhry, M.J.; Arshad, M.; et al. Diclofenac residues as the cause of vulture population decline in Pakistan. Nature 2004, 427, 630–633. [Google Scholar] [CrossRef]
  20. Brozinski, J.M.; Lahti, M.; Meierjohann, A.; Oikari, A.; Kronberg, L. The anti-inflammatory drugs diclofenac, naproxen and ibuprofen are found in the bile of wild fish caught downstream of a wastewater treatment plant. Env. Sci Technol 2013, 47, 342–348. [Google Scholar] [CrossRef]
  21. Zheng, M.; Chen, J.; Zhang, L.; Cheng, Y.; Lu, C.; Liu, Y.; Singh, A.; Trivedi, M.; Kumar, A.; Liu, J. Metal organic frameworks as efficient adsorbents for drugs from wastewater. Mater. Today Commun. 2022, 31, 103514. [Google Scholar] [CrossRef]
  22. Yadav, A.K.; Dash, P.; Mohanty, A.; Abbassi, R.; Mishra, B.K. Performance assessment of innovative constructed wetland-microbial fuel cell for electricity production and dye removal. Ecol. Eng. 2012, 47, 126–131. [Google Scholar] [CrossRef]
  23. Vymazal, J.; Zhao, Y.; Mander, Ü. Recent research challenges in constructed wetlands for wastewater treatment: A review. Ecol. Eng. 2021, 169, 106318. [Google Scholar] [CrossRef]
  24. Doherty, L.; Zhao, Y. Operating a two-stage microbial fuel cell-constructed wetland for fuller wastewater treatment and more efficient electricity generation. Water Sci. Technol. A J. Int. Assoc. Water Pollut. Res. 2015, 72, 421–428. [Google Scholar] [CrossRef] [PubMed]
  25. Healy, M.G.; Rodgers, M.; Mulqueen, J. Treatment of dairy wastewater using constructed wetlands and intermittent sand filters. Bioresour. Technol. 2007, 98, 2268–2281. [Google Scholar] [CrossRef]
  26. Patil, R.; Zahid, M.; Govindwar, S.; Khandare, R.; Vyavahare, G.; Gurav, R.; Desai, N.; Pandit, S.; Jadhav, J. Chapter 8—Constructed wetland: A promising technology for the treatment of hazardous textile dyes and effluent. In Development in Wastewater Treatment Research and Processes; Shah, M., Rodriguez-Couto, S., Biswas, J., Eds.; Elsevier: Amsterdam, The Netherlands, 2022; pp. 173–198. [Google Scholar]
  27. Sudarsan, J.S.; Annadurai, R.; Mukhopadhyay, M.; Chakraborty, P.; Nithiyanantham, S. Domestic wastewater treatment using constructed wetland: An efficient and alternative way. Sustain. Water Resour. Manag. 2018, 4, 781–787. [Google Scholar] [CrossRef]
  28. Vymazal, J. Constructed wetlands for treatment of industrial wastewaters: A review. Ecol. Eng. 2014, 73, 724–751. [Google Scholar] [CrossRef]
  29. Reyes-Contreras, C.; Matamoros, V.; Ruiz, I.; Soto, M.; Bayona, J.M. Evaluation of PPCPs removal in a combined anaerobic digester-constructed wetland pilot plant treating urban wastewater. Chemosphere 2011, 84, 1200–1207. [Google Scholar] [CrossRef]
  30. Hartl, M.; García-Galán, M.J.; Matamoros, V.; Fernández-Gatell, M.; Rousseau, D.P.L.; Du Laing, G.; Garfí, M.; Puigagut, J. Constructed wetlands operated as bioelectrochemical systems for the removal of organic micropollutants. Chemosphere 2021, 271, 129593. [Google Scholar] [CrossRef]
  31. Li, H.; Zhang, S.; Yang, X.-L.; Yang, Y.-L.; Xu, H.; Li, X.-N.; Song, H.-L. Enhanced degradation of bisphenol A and ibuprofen by an up-flow microbial fuel cell-coupled constructed wetland and analysis of bacterial community structure. Chemosphere 2019, 217, 599–608. [Google Scholar] [CrossRef]
  32. Wang, J.; Wang, S. Removal of pharmaceuticals and personal care products (PPCPs) from wastewater: A review. J. Environ. Manag. 2016, 182, 620–640. [Google Scholar] [CrossRef]
  33. Oon, Y.-L.; Ong, S.-A.; Ho, L.-N.; Wong, Y.-S.; Oon, Y.-S.; Lehl, H.K.; Thung, W.-E. Hybrid system up-flow constructed wetland integrated with microbial fuel cell for simultaneous wastewater treatment and electricity generation. Bioresour. Technol. 2015, 186, 270–275. [Google Scholar] [CrossRef] [PubMed]
  34. Doherty, L.; Zhao, Y.; Zhao, X.; Hu, Y.; Hao, X.; Xu, L.; Liu, R. A review of a recently emerged technology: Constructed wetland – Microbial fuel cells. Water Res. 2015, 85, 38–45. [Google Scholar] [CrossRef] [PubMed]
  35. Kadlec, R.H. Comparison of free water and horizontal subsurface treatment wetlands. Ecol. Eng. 2009, 35, 159–174. [Google Scholar] [CrossRef]
  36. Zhu, M.; Zhang, M.; Yuan, Y.; Zhang, P.; Du, S.; Ya, T.; Chen, D.; Wang, X.; Zhang, T. Responses of microbial communities and their interactions to ibuprofen in a bio-electrochemical system. J. Environ. Manag. 2021, 289, 112473. [Google Scholar] [CrossRef]
  37. Dai, M.; Zhang, Y.; Wu, Y.; Sun, R.; Zong, W.; Kong, Q. Mechanism involved in the treatment of sulfamethoxazole in wastewater using a constructed wetland microbial fuel cell system. J. Environ. Chem. Eng. 2021, 9, 106193. [Google Scholar] [CrossRef]
  38. Ge, X.Y.; Cao, X.; Song, X.S.; Wang, Y.H.; Si, Z.H.; Zhao, Y.F.; Wang, W.T.; Tesfahunegn, A.A. Bioenergy generation and simultaneous nitrate and phosphorus removal in a pyrite-based constructed wetland-microbial fuel cell. Bioresour. Technol. 2020, 296, 10. [Google Scholar] [CrossRef]
  39. Liu, X.; Guo, X.; Liu, Y.; Lu, S.; Xi, B.; Zhang, J.; Wang, Z.; Bi, B. A review on removing antibiotics and antibiotic resistance genes from wastewater by constructed wetlands: Performance and microbial response. Environ. Pollut. 2019, 254, 112996. [Google Scholar] [CrossRef]
  40. Pan, M.; Chu, L.M. Adsorption and degradation of five selected antibiotics in agricultural soil. Sci. Total Environ. 2016, 545–546, 48–56. [Google Scholar] [CrossRef]
  41. Du, L.; Zhao, Y.; Wang, C.; Zhang, H.; Chen, Q.; Zhang, X.; Zhang, L.; Wu, J.; Wu, Z.; Zhou, Q. Removal performance of antibiotics and antibiotic resistance genes in swine wastewater by integrated vertical-flow constructed wetlands with zeolite substrate. Sci. Total Environ. 2020, 721, 137765. [Google Scholar] [CrossRef]
  42. Chen, J.; Xie, S. Overview of sulfonamide biodegradation and the relevant pathways and microorganisms. Sci. Total Environ. 2018, 640–641, 1465–1477. [Google Scholar] [CrossRef]
  43. Kovalakova, P.; Cizmas, L.; McDonald, T.J.; Marsalek, B.; Feng, M.; Sharma, V.K. Occurrence and toxicity of antibiotics in the aquatic environment: A review. Chemosphere 2020, 251, 126351. [Google Scholar] [CrossRef] [PubMed]
  44. Nsenga Kumwimba, M.; Meng, F. Roles of ammonia-oxidizing bacteria in improving metabolism and cometabolism of trace organic chemicals in biological wastewater treatment processes: A review. Sci. Total Environ. 2019, 659, 419–441. [Google Scholar] [CrossRef] [PubMed]
  45. Popa, C.; Favier, L.; Dinica, R.; Semrany, S.; Djelal, H.; Amrane, A.; Bahrim, G. Potential of newly isolated wild Streptomyces strains as agents for the biodegradation of a recalcitrant pharmaceutical, carbamazepine. Environ. Technol. 2014, 35, 3082–3091. [Google Scholar] [CrossRef] [PubMed]
  46. Zhang, J.-J.; Chen, Y.-F.; Fang, T.; Zhou, N.-Y. Co-metabolic degradation of tribenuron methyl, a sulfonylurea herbicide, by Pseudomonas sp. strain NyZ42. Int. Biodeterior. Biodegrad. 2013, 76, 36–40. [Google Scholar] [CrossRef]
  47. Domaradzka, D.; Guzik, U.; Hupert-Kocurek, K.; Wojcieszyńska, D. Cometabolic Degradation of Naproxen by Planococcus sp. Strain S5. Water Air Soil Pollut. 2015, 226, 297. [Google Scholar] [CrossRef]
  48. Xie, S.; Liu, J.; Li, L.; Qiao, C. Biodegradation of malathion by Acinetobacter johnsonii MA19 and optimization of cometabolism substrates. J. Environ. Sci. 2009, 21, 76–82. [Google Scholar] [CrossRef]
  49. Pant, D.; Van Bogaert, G.; Diels, L.; Vanbroekhoven, K. A review of the substrates used in microbial fuel cells (MFCs) for sustainable energy production. Bioresour. Technol. 2010, 101, 1533–1543. [Google Scholar] [CrossRef]
  50. Wang, H.; Heil, D.; Ren, Z.J.; Xu, P. Removal and fate of trace organic compounds in microbial fuel cells. Chemosphere 2015, 125, 94–101. [Google Scholar] [CrossRef]
  51. Fadzli, F.S.; Bhawani, S.A.; Adam Mohammad, R.E.; Maneiro, M. Microbial Fuel Cell: Recent Developments in Organic Substrate Use and Bacterial Electrode Interaction. J. Chem. 2021, 2021, 4570388. [Google Scholar] [CrossRef]
  52. Wang, J.; Song, X.; Wang, Y.; Bai, J.; Li, M.; Dong, G.; Lin, F.; Lv, Y.; Yan, D. Bioenergy generation and rhizodegradation as affected by microbial community distribution in a coupled constructed wetland-microbial fuel cell system associated with three macrophytes. Sci. Total Environ. 2017, 607–608, 53–62. [Google Scholar] [CrossRef]
  53. Fang, Z.; Song, H.-l.; Cang, N.; Li, X.-n. Electricity production from Azo dye wastewater using a microbial fuel cell coupled constructed wetland operating under different operating conditions. Biosens. Bioelectron. 2015, 68, 135–141. [Google Scholar] [CrossRef] [PubMed]
  54. Hijosa-Valsero, M.; Reyes-Contreras, C.; Domínguez, C.; Bécares, E.; Bayona, J.M. Behaviour of pharmaceuticals and personal care products in constructed wetland compartments: Influent, effluent, pore water, substrate and plant roots. Chemosphere 2016, 145, 508–517. [Google Scholar] [CrossRef] [PubMed]
  55. Li, H.; Xu, H.; Song, H.-L.; Lu, Y.; Yang, X.-L. Antibiotic resistance genes, bacterial communities, and functions in constructed wetland-microbial fuel cells: Responses to the co-stresses of antibiotics and zinc. Environ. Pollut. 2020, 265, 115084. [Google Scholar] [CrossRef] [PubMed]
  56. APHA. Standard Methods for the Examination of Water and Wastewater, 23rd ed.; American Public Health Association: Washington, DC, USA; American Water Works Association: Washington, DC, USA, 2018. [Google Scholar]
  57. Fang, Z.; Song, H.L.; Yu, R.; Li, X.N. A microbial fuel cell-coupled constructed wetland promotes degradation of azo dye decolorization products. Ecol. Eng. 2016, 94, 455–463. [Google Scholar] [CrossRef]
  58. Bokulich, N.A.; Subramanian, S.; Faith, J.J.; Gevers, D.; Gordon, J.I.; Knight, R.; Mills, D.A.; Caporaso, J.G. Quality-filtering vastly improves diversity estimates from Illumina amplicon sequencing. Nat. Methods 2013, 10, 57–59. [Google Scholar] [CrossRef]
  59. Fang, Z.; Song, H.-L.; Cang, N.; Li, X.-N. Performance of microbial fuel cell coupled constructed wetland system for decolorization of azo dye and bioelectricity generation. Bioresour. Technol. 2013, 144, 165–171. [Google Scholar] [CrossRef]
  60. Yi, X.; Tran, N.H.; Yin, T.; He, Y.; Gin, K.Y.-H. Removal of selected PPCPs, EDCs, and antibiotic resistance genes in landfill leachate by a full-scale constructed wetlands system. Water Res. 2017, 121, 46–60. [Google Scholar] [CrossRef]
  61. Stülten, D.; Zühlke, S.; Lamshöft, M.; Spiteller, M. Occurrence of diclofenac and selected metabolites in sewage effluents. Sci. Total Environ. 2008, 405, 310–316. [Google Scholar] [CrossRef]
  62. Yang, Y.; Wang, Z.; He, T.; Dai, Y.; Xie, S. Sediment bacterial communities associated with anaerobic biodegradation of bisphenol A. Microb. Ecol. 2015, 70, 97–104. [Google Scholar] [CrossRef]
  63. Zhang, L.; Liu, Y.; Lv, S.; Wang, R.; Wang, Y.; Lin, K.; Hu, X.; Liu, Y.; Dong, Z.; Liu, L. An overview on constructed wetland-microbial fuel cell: Greenhouse gases emissions and extracellular electron transfer. J. Environ. Chem. Eng. 2023, 11, 109551. [Google Scholar] [CrossRef]
  64. Logan, B.E.; Regan, J.M. Microbial Fuel Cells—Challenges and Applications. Environ. Sci. Technol. 2006, 40, 5172–5180. [Google Scholar] [CrossRef] [PubMed]
  65. Xia, Z.; Xiao-chun, W.; Zhong-lin, C.; Hao, X.; Qing-fang, Z. Microbial community structure and pharmaceuticals and personal care products removal in a membrane bioreactor seeded with aerobic granular sludge. Appl. Microbiol. Biotechnol. 2015, 99, 425–433. [Google Scholar] [CrossRef] [PubMed]
  66. Xu, F.; Cao, F.Q.; Kong, Q.; Zhou, L.L.; Yuan, Q.; Zhu, Y.J.; Wang, Q.; Du, Y.D.; Wang, Z.D. Electricity production and evolution of microbial community in the constructed wetland-microbial fuel cell. Chem. Eng. J. 2018, 339, 479–486. [Google Scholar] [CrossRef]
  67. Zhu, C.-Y.; Wang, J.-F.; Li, Q.-S.; Wang, L.-L.; Tang, G.-H.; Cui, B.-S.; Bai, J. Integration of CW-MFC and anaerobic granular sludge to explore the intensified ammonification-nitrification-denitrification processes for nitrogen removal. Chemosphere 2021, 278, 130428. [Google Scholar] [CrossRef] [PubMed]
  68. Yang, Q.; Wu, Z.X.; Liu, L.F.; Zhang, F.X.; Liang, S.N. Treatment of Oil Wastewater and Electricity Generation by Integrating Constructed Wetland with Microbial Fuel Cell. Materials 2016, 9, 885. [Google Scholar] [CrossRef]
  69. Silambarasan, S.; Abraham, J. Biodegradation of carbendazim by a potent novel Chryseobacterium sp. JAS14 and plant growth promoting Aeromonas caviae JAS15 with subsequent toxicity analysis. 3 Biotech 2020, 10, 326. [Google Scholar] [CrossRef]
  70. Zhang, W.; Li, J.; Zhang, Y.; Wu, X.; Zhou, Z.; Huang, Y.; Zhao, Y.; Mishra, S.; Bhatt, P.; Chen, S. Characterization of a novel glyphosate-degrading bacterial species, Chryseobacterium sp. Y16C, and evaluation of its effects on microbial communities in glyphosate-contaminated soil. J. Hazard. Mater. 2022, 432, 128689. [Google Scholar] [CrossRef]
  71. Figueroa, D.; Capo, E.; Lindh, M.V.; Rowe, O.F.; Paczkowska, J.; Pinhassi, J.; Andersson, A. Terrestrial dissolved organic matter inflow drives temporal dynamics of the bacterial community of a subarctic estuary (northern Baltic Sea). Env. Microbiol 2021, 23, 4200–4213. [Google Scholar] [CrossRef]
  72. Xu, B.; Gao, P.; Liu, Z.; Xue, G.; Liu, Y.; Wu, F. Influence of Cosubstrates on Iopromide Degradation by Pseudomonas sp. I-24. Water Air Soil Pollut. 2014, 225, 1849. [Google Scholar] [CrossRef]
  73. Lawson, K. Emerging pharmacological strategies for the treatment of fibromyalgia. World J. Pharmacol. 2017, 6, 1–10. [Google Scholar] [CrossRef]
  74. Liu, C.; Liu, T.; Zheng, X.; Meng, J.; Chen, H.; Yuan, Z.; Hu, S.; Guo, J. Rapid formation of granules coupling n-DAMO and anammox microorganisms to remove nitrogen. Water Res. 2021, 194, 116963. [Google Scholar] [CrossRef] [PubMed]
  75. Corbella, C.; Guivernau, M.; Vinas, M.; Puigagut, J. Operational, design and microbial aspects related to power production with microbial fuel cells implemented in constructed wetlands. Water Res. 2015, 84, 232–242. [Google Scholar] [CrossRef] [PubMed]
  76. Huang, X.; Zheng, J.; Liu, C.; Liu, L.; Liu, Y.; Fan, H.; Zhang, T. Performance and bacterial community dynamics of vertical flow constructed wetlands during the treatment of antibiotics-enriched swine wastewater. Chem. Eng. J. 2017, 316, 727–735. [Google Scholar] [CrossRef]
  77. Zhao, X.; Chen, Z.; Wang, X.; Li, J.; Shen, J.; Xu, H. Remediation of pharmaceuticals and personal care products using an aerobic granular sludge sequencing bioreactor and microbial community profiling using Solexa sequencing technology analysis. Bioresour. Technol. 2015, 179, 104–112. [Google Scholar] [CrossRef]
  78. Vymazal, J. Constructed wetlands for wastewater treatment. Ecol. Eng. 2005, 25, 475–477. [Google Scholar] [CrossRef]
  79. Oon, Y.L.; Ong, S.A.; Ho, L.N.; Wong, Y.S.; Dahalan, F.A.; Oon, Y.S.; Teoh, T.P.; Lehl, H.K.; Thung, W.E. Constructed wetland-microbial fuel cell for azo dyes degradation and energy recovery: Influence of molecular structure, kinetics, mechanisms and degradation pathways. Sci. Total Environ. 2020, 720, 15. [Google Scholar] [CrossRef]
  80. Song, H.L.; Zhang, S.; Guo, J.H.; Yang, Y.L.; Zhang, L.M.; Li, H.; Yang, X.L.; Liu, X. Vertical up-flow constructed wetlands exhibited efficient antibiotic removal but induced antibiotic resistance genes in effluent. Chemosphere 2018, 203, 434–441. [Google Scholar] [CrossRef]
  81. Ebrahimi, A.; Sivakumar, M.; McLauchlan, C.; Ansari, A.; Vishwanathan, A.S. A critical review of the symbiotic relationship between constructed wetland and microbial fuel cell for enhancing pollutant removal and energy generation. J. Environ. Chem. Eng. 2021, 9, 105011. [Google Scholar] [CrossRef]
  82. Sonawane, J.M.; Yadav, A.; Ghosh, P.C.; Adeloju, S.B. Recent advances in the development and utilization of modern anode materials for high performance microbial fuel cells. Biosens. Bioelectron. 2017, 90, 558–576. [Google Scholar] [CrossRef]
  83. Sizirici, B.; Yildiz, I. Simultaneous removal of organics and metals in fixed bed using gravel and iron oxide coated gravel. Results Eng. 2020, 5, 100093. [Google Scholar] [CrossRef]
  84. Oon, Y.-L.; Ong, S.-A.; Ho, L.-N.; Wong, Y.-S.; Dahalan, F.A.; Oon, Y.-S.; Lehl, H.K.; Thung, W.-E. Synergistic effect of up-flow constructed wetland and microbial fuel cell for simultaneous wastewater treatment and energy recovery. Bioresour. Technol. 2016, 203, 190–197. [Google Scholar] [CrossRef] [PubMed]
  85. Zhao, C.C.; Shang, D.W.; Zou, Y.L.; Du, Y.D.; Wang, Q.; Xu, F.; Ren, L.; Kong, Q. Changes in electricity production and microbial community evolution constructed wetland -microbial fuel cell exposed to wastewater containing Pb(II). Sci. Total Environ. 2020, 732, 11. [Google Scholar] [CrossRef] [PubMed]
  86. González, T.; Puigagut, J.; Vidal, G. Organic matter removal and nitrogen transformation by a constructed wetland-microbial fuel cell system with simultaneous bioelectricity generation. Sci. Total Environ. 2021, 753, 142075. [Google Scholar] [CrossRef]
  87. Wu, D.; Yang, L.Y.; Gan, L.; Chen, Q.K.; Li, L.; Chen, X.; Wang, X.; Guo, L.Y.; Miao, A.J. Potential of novel wastewater treatment system featuring microbial fuel cell to generate electricity and remove pollutants. Ecol. Eng. 2015, 84, 624–631. [Google Scholar] [CrossRef]
  88. Saz, Ç.; Türe, C.; Türker, O.C.; Yakar, A. Effect of vegetation type on treatment performance and bioelectric production of constructed wetland modules combined with microbial fuel cell (CW-MFC) treating synthetic wastewater. Environ. Sci. Pollut. Res. 2018, 25, 8777–8792. [Google Scholar] [CrossRef]
  89. Araneda, I.; Tapia, N.F.; Allende, K.L.; Vargas, I.T. Constructed Wetland-Microbial Fuel Cells for Sustainable Greywater Treatment. Water 2018, 10, 940. [Google Scholar] [CrossRef]
  90. Liu, Q.; Zhou, B.X.; Zhang, S.C.; Xu, D.; Pan, R.; Xia, S.B. Embedding Microbial Fuel Cells into the Vertical Flow Constructed Wetland Enhanced Denitrogenation and Water Purification. Pol. J. Environ. Stud. 2019, 28, 1799–1804. [Google Scholar] [CrossRef]
  91. Zhang, S.; Song, H.-L.; Yang, X.-L.; Li, H.; Wang, Y.-W. A system composed of a biofilm electrode reactor and a microbial fuel cell-constructed wetland exhibited efficient sulfamethoxazole removal but induced sul genes. Bioresour. Technol. 2018, 256, 224–231. [Google Scholar] [CrossRef]
  92. Pepè Sciarria, T.; Arioli, S.; Gargari, G.; Mora, D.; Adani, F. Monitoring microbial communities’ dynamics during the start-up of microbial fuel cells by high-throughput screening techniques. Biotechnol. Rep. 2019, 21, e00310. [Google Scholar] [CrossRef]
  93. Zhang, L.; Zhu, X.; Li, J.; Liao, Q.; Ye, D. Biofilm formation and electricity generation of a microbial fuel cell started up under different external resistances. J. Power Sources 2011, 196, 6029–6035. [Google Scholar] [CrossRef]
  94. Chae, K.-J.; Choi, M.-J.; Lee, J.-W.; Kim, K.-Y.; Kim, I.S. Effect of different substrates on the performance, bacterial diversity, and bacterial viability in microbial fuel cells. Bioresour. Technol. 2009, 100, 3518–3525. [Google Scholar] [CrossRef] [PubMed]
  95. Dong, X.; Li, D.; Li, Y.; Sakiyama, H.; Muddassir, M.; Pan, Y.; Srivastava, D.; Kumar, A. A 3,8-connected Cd(ii)-based metal–organic framework as an appropriate luminescent sensor for the antibiotic sulfasalazine. CrystEngComm 2022, 24, 7157–7165. [Google Scholar] [CrossRef]
  96. Bin, H.-S.; Hu, H.; Wang, J.; Lu, L.; Muddassir, M.; Srivastava, D.; Chauhan, R.; Wu, Y.; Wang, X.; Kumar, A. New 5,5-(1,4-Phenylenebis(methyleneoxy)diisophthalic Acid Appended Zn(II) and Cd(II) MOFs as Potent Photocatalysts for Nitrophenols. Molecules 2023, 28, 7180. [Google Scholar] [CrossRef] [PubMed]
Figure 1. The schematic diagram of CW-MFC (1 water tank; 2 peristaltic pump; 3&4 stainless steel mesh; 5 Iris pseudacorus; 6 resistor; 7 data acquisition module; 8 computer).
Figure 1. The schematic diagram of CW-MFC (1 water tank; 2 peristaltic pump; 3&4 stainless steel mesh; 5 Iris pseudacorus; 6 resistor; 7 data acquisition module; 8 computer).
Water 15 03862 g001
Figure 2. The chemical structures of IBP (A) and DCF (B).
Figure 2. The chemical structures of IBP (A) and DCF (B).
Water 15 03862 g002
Figure 3. Indicator bacterial with LDA scores of 4 or greater in anodes and cathodes with different co-substrate combinations: (A) IBP-Glu, (B) IBP-Suc, (C) IBP-SA, (D) DCF-Glu, (E) DCF-Suc, (F) DCF-SA.
Figure 3. Indicator bacterial with LDA scores of 4 or greater in anodes and cathodes with different co-substrate combinations: (A) IBP-Glu, (B) IBP-Suc, (C) IBP-SA, (D) DCF-Glu, (E) DCF-Suc, (F) DCF-SA.
Water 15 03862 g003
Figure 4. Indicator bacterial with LDA scores of 4 or greater in cathodes and anodes of CW-MFC devices. (A) Anode treated with IBP; (B) cathode treated with DCF; (C) anode treated with DCF.
Figure 4. Indicator bacterial with LDA scores of 4 or greater in cathodes and anodes of CW-MFC devices. (A) Anode treated with IBP; (B) cathode treated with DCF; (C) anode treated with DCF.
Water 15 03862 g004
Figure 5. Principal Coordinates Analysis (PCoA) for the β-diversity between devices of CM-A, CM-B, and CM-C at the cathodes and anodes. (A) Cathode treated with IBP; (B) anode treated with IBP; (C) cathode treated with DCF; (D) anode treated with DCF.
Figure 5. Principal Coordinates Analysis (PCoA) for the β-diversity between devices of CM-A, CM-B, and CM-C at the cathodes and anodes. (A) Cathode treated with IBP; (B) anode treated with IBP; (C) cathode treated with DCF; (D) anode treated with DCF.
Water 15 03862 g005
Figure 6. Redundancy analysis (RDA) between samples and environmental variables (Glu, Suc, SA, NH4+-N, TN, and TP). (A) Cathode treated with IBP; (B) Anode treated with IBP; (C) Cathode treated with DCF; (D) Anode treated with DCF.
Figure 6. Redundancy analysis (RDA) between samples and environmental variables (Glu, Suc, SA, NH4+-N, TN, and TP). (A) Cathode treated with IBP; (B) Anode treated with IBP; (C) Cathode treated with DCF; (D) Anode treated with DCF.
Water 15 03862 g006
Figure 7. Correlation analysis of Glu, Suc, SA, NH4+-N, TN, and TP concentrations, as well as dominant bacteria in cathodes and anodes at the phylum level. Orange indicates negative correlations, while purple indicates positive correlations. The darker the color, the stronger the correlation (* p < 0.05, ** p < 0.01). (A) Cathode treated with IBP; (B) anode treated with IBP; (C) cathode treated with DCF; (D) anode treated with DCF.
Figure 7. Correlation analysis of Glu, Suc, SA, NH4+-N, TN, and TP concentrations, as well as dominant bacteria in cathodes and anodes at the phylum level. Orange indicates negative correlations, while purple indicates positive correlations. The darker the color, the stronger the correlation (* p < 0.05, ** p < 0.01). (A) Cathode treated with IBP; (B) anode treated with IBP; (C) cathode treated with DCF; (D) anode treated with DCF.
Water 15 03862 g007
Figure 8. DO variation over height in CW-MFC. * indicate significant differences, with * p < 0.05, ** p < 0.01.
Figure 8. DO variation over height in CW-MFC. * indicate significant differences, with * p < 0.05, ** p < 0.01.
Water 15 03862 g008
Figure 9. Polarization curve and power density curve with different carbon sources.
Figure 9. Polarization curve and power density curve with different carbon sources.
Water 15 03862 g009
Table 1. IBP concentration of sampling ports and effluent using different carbon sources (mean ± SD, n = 3, the initial concentration of IBP is 10 mg·L−1. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05).
Table 1. IBP concentration of sampling ports and effluent using different carbon sources (mean ± SD, n = 3, the initial concentration of IBP is 10 mg·L−1. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05).
SampleIBP Concentration (mg·L−1)
Sampling
Port 4
Sampling
Port 5
Sampling
Port 10
EffluentTotal
Removal
CM-A
(IBP-Glu)
8.10 ± 0.04 Ab2.96 ± 0.03 Ba2.68 ± 0.04 Ca0.86 ± 0.04 Dc9.14 ± 0.04 a
CM-C
(IBP-SA)
7.93 ± 0.07 Ac2.21 ± 0.05 Bc2.13 ± 0.08 Bb1.28 ± 0.05 Ca8.72 ± 0.05 c
CM-B
(IBP-Suc)
8.36 ± 0.03 Aa2.71 ± 0.02 Bb2.63 ± 0.02 Ca1.08 ± 0.05 Db8.92 ± 0.05 b
Table 2. DCF concentration of removal of sampling ports and effluent using different carbon sources (mean ± SD, n = 3, the initial concentration of DCF is 10 mg·L−1. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05.).
Table 2. DCF concentration of removal of sampling ports and effluent using different carbon sources (mean ± SD, n = 3, the initial concentration of DCF is 10 mg·L−1. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05.).
SampleDCF Concentration (mg·L−1)
Sampling
Port 4
Sampling
Port 5
Sampling
Port 10
EffluentTotal
Removal
CM-A
(DCF-Glu)
6.53 ± 0.13 Aa2.67 ± 0.18 Ba1.82 ± 0.03 Ca1.56 ± 0.03 Db8.44 ± 0.03 a
CM-C
(DCF-SA)
5.85 ± 0.09 Ac2.47 ± 0.09 Bab1.71 ± 0.02 Cb1.64 ± 0.03 Ca8.36 ± 0.03 b
CM-B
(DCF-Suc)
6.19 ± 0.01 Ab2.35 ± 0.06 Bb1.69 ± 0.03 Cb1.57 ± 0.03 Db8.43 ± 0.03 a
Table 3. Microbial diversity indices of samples in CW-MFC systems. Note: Observed bacterial community richness is based on the OTUs in each sample (Mean ± SD, n = 3); values with superscript letters a, b, and c are significantly different between groups (p < 0.05).
Table 3. Microbial diversity indices of samples in CW-MFC systems. Note: Observed bacterial community richness is based on the OTUs in each sample (Mean ± SD, n = 3); values with superscript letters a, b, and c are significantly different between groups (p < 0.05).
PPCPsElectrodesCo-SubstratesSobsShannonSimpsonAceChaoCoverage
IBPAnodeGlu2881.33 ± 49.01 a5.87 ± 0.24 a0.03 ± 0.01 a3892.87 ± 105.76 a3825.06 ± 56.04 a0.98 ± 0.00 a
Suc2757.00 ± 52.72 a6.23 ± 0.03 a0.01 ± 0.00 a3794.56 ± 142.26 a3796.97 ± 141.16 a0.98 ± 0.00 a
SA2762.00 ± 254.21 a5.93 ± 0.36 a0.03 ± 0.02 a3831.85 ± 275.12 a3799.76 ± 274.84 a0.97 ± 0.00 a
CathodeGlu1749.33 ± 1029.82 a4.81 ± 0.51 a0.09 ± 0.11 a2184.98 ± 1455.08 a2189.47 ± 1424.96 a0.99 ± 0.01 a
Suc1203.33 ± 238.83 a4.78 ± 0.52 a0.04 ± 0.02 a1537.54 ± 391.85 a1539.05 ± 390.24 a0.99 ± 0.00 a
SA1283.67 ± 136.45 a4.74 ± 0.20 a0.04 ± 0.01 a1695.22 ± 231.98 a1704.14 ± 243.42 a0.99 ± 0.00 a
DCFAnodeGlu2756.00 ± 352.74 a6.17 ± 0.25 a0.01 ± 0.01 b3698.78 ± 357.71 ab3701.06 ± 349.67 b0.98 ± 0.00 a
Suc3063.67 ± 101.66 a6.39 ± 0.20 a0.01 ± 0.00 b4198.98 ± 55.07 a4204.49 ± 91.35 a0.97 ± 0.00 a
SA2076.00 ± 107.14 b4.35 ± 0.51 b0.17 ± 0.07 a3486.38 ± 310.01 b3035.99 ± 55.31 c0.97 ± 0.00 a
CathodeGlu1524.33 ± 64.84 a5.18 ± 0.11 a0.02 ± 0.00 b1958.90 ± 14.05 a1921.94 ± 7.78 a0.99 ± 0.00 a
Suc1616.67 ± 214.28 a5.42 ± 0.17 a0.02 ± 0.00 b2228.25 ± 285.18 a2218.17 ± 307.39 b0.98 ± 0.00 b
SA1124.00 ± 226.10 b4.26 ± 0.50 b0.05 ± 0.02 a1642.83 ± 429.71 a1569.71 ± 239.39 a0.99 ± 0.00 a
Table 4. Concentrations of COD, NH4+-N, TN, and TP of sampling ports and effluent using different carbon sources. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05 (mean ± SD, n = 3).
Table 4. Concentrations of COD, NH4+-N, TN, and TP of sampling ports and effluent using different carbon sources. Uppercase and lowercase letters represent intra-group and inter-group differences, respectively. Different letters indicate significant differences, with p < 0.05 (mean ± SD, n = 3).
PollutantsSamplesConcentration (mg·L−1)
Sampling
Port 4
Sampling
Port 5
Sampling
Port 10
EffluentTotal
Removal
CODCM-A175.40 ± 2.29 Aa42.33 ± 7.22 Bb25.36 ± 6.69 Cb19.94 ± 6.98 Ca280.06 ± 6.98 a
CM-B170.70 ± 2.29 Ab64.92 ± 2.17 Ba47.48 ± 1.78 Ca43.46 ± 1.73 Db256.54 ± 1.73 b
CM-C119.10 ± 0.70 Ac42.83 ± 2.00 Bb27.02 ± 2.22 Cb25.27 ± 2.27 Cb274.73 ± 2.27 a
NH4+-NCM-A23.61 ± 0.01 Aa17.30 ± 0.01 Bb16.86 ± 0.01 Cb9.60 ± 0.06 Dc25.20 ± 0.06 a
CM-B22.41 ± 0.02 Ab18.82 ± 0.01 Ba18.55 ± 0.02 Ca13.12 ± 0.06 Db21.68 ± 0.06 b
CM-C18.99 ± 0.12 Ac16.34 ± 0.13 Bc16.25 ± 0.12 Bc14.46 ± 0.10 Ca20.34 ± 0.10 b
TNCM-A21.16 ± 0.01 Ab13.42 ± 0.08 Bc12.52 ± 0.15 Cc3.87 ± 0.19 Dc30.93 ± 0.19 a
CM-B22.04 ± 0.07 Aa16.59 ± 0.00 Ba15.97 ± 0.03 Ca9.64 ± 0.00 Db25.16 ± 0.00 b
CM-C18.22 ± 0.11 Ac14.50 ± 0.04 Bb14.02 ± 0.08 Cb10.65 ± 0.04 Da24.15 ± 0.04 c
TPCM-A273.09 ± 0.30 Ac235.49 ± 0.39 Bc189.80 ± 0.87 Cc148.07 ± 0.39 Dc227.93 ± 0.39 a
CM-B274.86 ± 0.33 Ab243.06 ± 0.22 Bb203.72 ± 0.60 Cb163.95 ± 0.63 Db212.05 ± 0.63 b
CM-C293.00 ± 0.30 Aa272.91 ± 1.39 Ba241.59 ± 0.96 Ca213.58 ± 1.32 Da162.42 ± 1.32 c
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Qin, G.; Feng, H.; Yu, R.; Zheng, F.; Jiang, X.; Xia, L.; An, S. Study on the Removal Characteristics of IBP and DCF in Wastewater by CW-MFC with Different Co-Substrates. Water 2023, 15, 3862. https://doi.org/10.3390/w15213862

AMA Style

Qin G, Feng H, Yu R, Zheng F, Jiang X, Xia L, An S. Study on the Removal Characteristics of IBP and DCF in Wastewater by CW-MFC with Different Co-Substrates. Water. 2023; 15(21):3862. https://doi.org/10.3390/w15213862

Chicago/Turabian Style

Qin, Ge, Hongyu Feng, Rendong Yu, Fuchao Zheng, Xufei Jiang, Lu Xia, and Shuqing An. 2023. "Study on the Removal Characteristics of IBP and DCF in Wastewater by CW-MFC with Different Co-Substrates" Water 15, no. 21: 3862. https://doi.org/10.3390/w15213862

APA Style

Qin, G., Feng, H., Yu, R., Zheng, F., Jiang, X., Xia, L., & An, S. (2023). Study on the Removal Characteristics of IBP and DCF in Wastewater by CW-MFC with Different Co-Substrates. Water, 15(21), 3862. https://doi.org/10.3390/w15213862

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop