2. The Method
The proposed method is based on interferometry as a tool for mass (or mass ratio) measurements of particles and antiparticles. The interferometer can be considered (for given geometrical parameters) as a spectrometer whose task is measuring the de Broglie wavelength of the particle. The mass of the particle is then calculated by inverting the de Broglie relation. Namely, the de Broglie wavelength [
17] is defined as
where
h is the Planck’s constant and
p is the relativistic particle momentum. Denoting with
K the particle kinetic energy, one has
with
c the speed of light and
m the rest mass of the particle. Inverting the previous relation in terms of the rest energy, one obtains
In a possible proposed configuration (see
Figure 1) the kinetic energy of the particles is determined by an acceleration stage. The uncertainties on
K are influenced in general by the initial velocity distribution of the particles and by the uncertainty on the potentials applied along the acceleration beamline.
In order to reduce the kinetic energy spread, a suitable (combination of) Wien filter(s) may be introduced (see again
Figure 1). A Wien filter is a device consisting of orthogonal electric and magnetic fields, such that the Lorentz force for charged particles traveling with a velocity
orthogonal to both fields vanishes, so that the trajectory of these particles is unaffected while all other particles are deflected [
18,
19]. For the present purposes, we assume that the
ratio is adjustable around the expected velocity value:
The actual velocity at the exit from the Wien filter could then be selected as that which maximizes the output particle flux (and therefore the statistics for the subsequent analysis). This can be determined with a suitable detector on the optical axis of the filter just after the exit. The drawback is that this velocity is known within the uncertainties of the electric and magnetic fields inside the filter. The advantage is that these uncertainties can be much smaller than the uncertainty on K in the previous acceleration stage; moreover, these uncertainties become completely unimportant in a mass ratio estimate (see later). Pinholes after the exit from the Wien filter may further collimate the beam before the interferometric stage.
In order to estimate the mass of a particle/antiparticle or the mass ratio of a particle and its corresponding antiparticle, a Fraunhofer diffraction configuration is considered (see
Figure 1), with the goal of measuring the de Broglie wavelength of the particles.
Fraunhofer (far-field) diffraction occurs when the distance between the source and the diffraction object, as well as the distance between the diffraction object and the screen, is very large when compared with the wavelength of the incident wave.
A beam of particles with de Broglie wavelength impinging on the slit system (or grating) generates an interference and diffraction pattern that appears as an intensity modulation when observed on a plane located at a distance L from the grating and is observed by recording the flux of particles as a function of the lateral screen position with a position-sensitive detector.
The intensity (normalized over its maximum value) is given by
where
N is the number of slits,
, and
, with
a the width of the slits,
d the distance between (the centers of) successive slits, and
. Here,
y denotes the lateral position on the screen (
where the optical axis of the apparatus intercepts the screen).
Mathematically, the overall diffraction pattern is equivalent to that produced by N delta function (infinitesimal width) slits modulated by the intensity pattern of a single slit with finite width. The slit width a determines the distance between the minima of the diffraction envelope, whereas the separation d between the slits determines the distance between the minima of the interference pattern.
Here, we explicitly consider the use of a diffraction grating. The main advantage of this configuration over a diffracting system with a small number of slits is related to the reduced loss of particle statistics, which can represent an important problem especially when working with antimatter particles. For this same reason, the use of large opening slits is envisaged (
). A further advantage of the diffraction grating is the fact that by increasing
N the principal maxima become more intense (as the intensity scales with
), their full width at half maximum becomes smaller and smaller and their position tends to become independent from the width of the slit
a and given by the simple and well-known formula
The position of the first lateral interference maxima therefore correspond to a deviation from the center of the screen of
Inverting this relation
and inserting this result in the definition of the de Broglie wavelength (
2), one obtains
This formula gives the absolute mass of the particle in our proposed approach. The error on the mass therefore depends on the errors relevant to the electric (
E) and magnetic (
B) fields in the velocity selector, the distance
L between grating and screen, the grating pitch
d, and the distance
between the central and first lateral interference maxima (average distance of the first maxima on both sides). In order to evaluate this error in a possible real experiment, we consider here the case of nuclear emulsion detectors [
20,
21,
22]. In this case, the intrinsic resolution can reach 50 nm [
23,
24].
To estimate the particle statistics needed to reach a given resolution (this issue can be of critical importance in the case of antimatter particles), we have performed a simple Monte Carlo simulation. The events are randomly extracted according to the theoretical distribution (
4) and are plotted in a histogram with the bin width equal to the expected resolution of the detector. As the error analysis indicates (see later) that the overall accuracy of the measurement is strongly affected by the accuracy on
, we consider explicitly the case of the most accurate potentially reachable resolution of the emulsion, i.e., a bin width of 50 nm.
The Monte Carlo simulations confirm that for a given particle statistics the diffraction grating is preferable with respect to a few-slits system, as the interference peaks can be determined with a better resolution. The data reported in
Figure 2 and
Figure 3 refer to a distribution of particles of 10 keV kinetic energy on a screen located 1 m behind a diffraction grating having
slits with
μm and
μm. One of the two first lateral interference peaks is fitted with a Gaussian distribution in an interval symmetric around the expected maximum position and for a counting level above approximately 10% of the maximum level. In the fitting procedure, the extrema of the interval are held fixed, whereas the central position and the spread of the Gaussian are free parameters. The error on the peak determination is defined as the absolute value of the difference between the theoretically expected maximum position and the central value of the Gaussian distribution obtained from the fit. Repeating the simulations for different numbers
of random particles, and using several seeds for each
, it is found that an error on the determination of the maximum position systematically smaller than 50 nm is achieved with
.
For a given detector, an example of error propagation analysis applied to the measurement of the positron mass based on Equation (
8) is shown in
Figure 4 and
Figure 5. The error is normalized over the presently accepted value of the electron rest mass,
[
25]. The analysis refers to realistically attainable fixed values of the errors on
d (see later) and
(intrinsic resolution of the emulsion detector). In this particular example,
m,
m, and the magnetic field strength is set to
T, whereas the intensity of the electric field
E is tuned to the particle velocity corresponding to
K (for
). For
K =10–20 keV, corresponding to the energy range of positrons in the QUPLAS-0 experiment [
16],
E would vary between approximately 500 and 1000 kV/m (for electrodes in the Wien filter spaced 10 mm apart, this corresponds to voltage differences of 5–10 kV between the electrodes; lower voltage differences can be considered with a smaller
B field). The relative error on both
E and
B is assumed to be
. Finally, for each
K the value of
is set to the theoretical value (
6) computed with the corresponding de Broglie wavelength (
1) and assuming again
.
In general, the error on the mass increases with the particle kinetic energy. For a given interferometric setup (fixed
L and
d), the separation between the maxima of interference increases as the energy of the particles decreases (and therefore the de Broglie wavelength increases), so that these maxima are more clearly detectable. On the other hand, low energy particle are more strongly deviated by (transverse) residual magnetic fields present in the interferometer region (see discussion section), and the lower particle energy limit is eventually set by the sensitivity of the emulsion detector [
22].
In addition, the error on the mass measurement turns out to be very weakly dependent on the relative errors on
E ad
B, while it is more strongly affected by the error on
(i.e., by the intrinsic resolution of the detector), as it is shown in
Figure 4, in particular at higher kinetic energies, and by the error on the slit spacing
d (see
Figure 5). In the latter case, this error becomes more important at lower kinetic energies.
Keeping the same values of
E and
B in the Wien filter, the selected velocity is equal for particles (mass
) and antiparticles (mass
), and using the same interference apparatus (i.e., the same values of
L and
d), one finds for the ratio of the masses
where
and
denote the distances between the first interference maxima for the particles of mass
and
, respectively, and the simplification in the last formula follows from the approximation
. In Equation (
9), the effect of
d,
E, and
B is eliminated. Some systematic errors tend therefore to cancel when the de Broglie wavelengths of a particle and of its antiparticle are measured in the same apparatus. An example of error propagation analysis on the mass ratio (
9) between positron and electron is shown in
Figure 6 (In the computations reported in
Figure 4,
Figure 5 and
Figure 6 the values of the universal constants are
Js (exact),
c = 299,792,458 m/s (exact),
C (exact) according to the 2019 revision of International System of Units [
26], and the value
kg (equivalent to
keV) for the electron rest mass [
25]). The results is computed for
μm, but the effect on the results of the statistical error on
L turns out to be completely negligible for reasonably small
mm values.
When making the proposed measurement of the particle/antiparticle ratio, care must be taken to minimize any effect due to a different beam structure (divergence, spatial coherence) between the two types of particle. This can be achieved with a careful collimation that allows to coherently illuminate the spatial acceptance of the Wien filter.
3. Positrons and Electrons
The concept of measuring the de Broglie wavelength of particle and antiparticle in the same apparatus must be considered in light of the experimental constraints. For the case of electron and positron, the limiting factor is the statistics of the antiparticle beam.
Positron beams can be obtained in linear accelerators, at MeV energies or higher, or from radioactive sources such as
Na. LINACs and high-energy facilities can offer high particles statistics [
27], but the de Broglie wavelength of the particles is very small and the inherent bunching of particles makes them less suitable for use in interferometry setups. On the other hand, radioactive
Na sources are employed that produce positrons by means of beta decays with a continuous distribution of kinetic energies up to 546 keV. These sources have an activity up to 50 mCi and the resulting positron spectra can be moderated to obtain a beam with well defined energy [
28]. This process involves sizable particle losses so that the typical intensity of these continuous beams is of the order of
–
particles per second.
Interferometry can be profitably used under these conditions. In order to estimate reasonable values of the main involved parameters and their relevant accuracies, we refer here explicitly to the recent QUPLAS-0 experiment [
15,
16]. The kinetic energy of the positrons in this experiment (of the order of 10 keV) gives de Broglie wavelengths of the order of 10 pm, which are suitable for interferometric studies with material gratings.
QUPLAS-0 makes use of material diffraction gratings with micrometric periodicity [
21,
29]. The positron beam impinges on the gratings and forms an interferometric pattern on an emulsion detector [
15,
16]. A collimation stage improves the beam coherence and a germanium detector is used to monitor the particle flux by means of the 511 keV gammas generated by positron annihilations.
The uncertainties on K are determined by the initial kinetic energy distribution of the positrons after their moderation (≃1 eV), for instance, in an -oriented tungsten single crystal foil with 1 m thickness, and by the uncertainty on the applied potentials (several keV) along the beamline, of the order of . As discussed above, these uncertainties can be reduced with the use of suitable velocity selectors.
To estimate the uncertainty on the period
d of the gratings used in the QUPLAS-0 experiment, we have to take into account that these gratings are extracted from a 100 mm diameter wafer [
29]. The grating image recorded on the wafer is obtained by interfering two beams with spherical wavefronts. The image is therefore not uniform, with the grating period very slowly getting larger when moving away from the center of the wafer. To a very good approximation, the change in period
divided by the nominal period (the period at the center of the wafer)
d is given by
, where
r is the distance from the center and
L is the length of the interferometer arms, which is about 0.90 m in the used apparatus [
29]. As a consequence, across each individual grating there is also a change in the period, but this error is about two orders of magnitude smaller than the error across a whole wafer.
The period of the “recorded” grating image was measured at the center of the exposure area, i.e., at the center of the wafer. The measured values are affected by random errors that are the result of an uncertainty in measuring angles (the rotation stage angle and the diffracted spot angle) [
29]. Considering only those random errors, the measured periods for two different gratings were
nm, and
nm. Unfortunately, the location of the used gratings on the original wafer is unknown. By picturing a Gaussian spatial distribution of the gratings on the wafer with width
and with the wafer edge corresponding to 3
, and assuming our gratings most likely come from within a distance
mm from the center (that is within approximately 1.5
), we can estimate
, which gives an error of
nm. Adding the two errors in quadrature, we obtain for the grating period
nm and
nm, respectively. Note that a comparably negligible contribution to the error comes also from the fact that the membranes may in principle distort due to temperature variations.
4. Discussion and Conclusions
In the previous analysis, we neglected all interactions of the interfering particles with the environment (e.g., van der Waals interactions). However, when transmitted by material gratings the particles are forced to pass at very short distances from the walls of the gratings (membranes with a slit width as small as 45 nm have been used in electron diffraction experiments [
30]). This inevitably results in an interaction mediated by a potential [
31]. Such issues might be avoided with the use of light gratings [
32].
It has also been implicitly assumed that the contrast is sufficiently high so that the periodicity of the pattern on the position-sensitive detector is clearly visible. Effects which may degrade the contrast are related to the misalignments of the optical elements, and the presence of external fields and/or beam–beam interactions. In particular, while working with charged particles a field-free environment is crucial for avoiding decoherence effects and pattern distortions within the interferometer. As indicated in
Figure 1, the interferometer can be placed inside a cylindrical mu-metal shield to reduce the effects of magnetic fields. Mu-metal is a nickel-iron soft ferromagnetic alloy with very high permeability, that leads to the concentration of the magnetic flux into the material, resulting in a lower field inside the tube. Typical shielding factors can reach 1000 or more. In any case, it has to be underlined that a global shift (linearly dependent on the strength of the residual magnetic field, and on opposite sides for particles and antiparticles) of the diffraction pattern will be unavoidably present due to the Earth’s magnetic field. This can be sizable especially at low kinetic energies: approximately 5 to 20
m for
K from 20 to 1 keV, assuming a constant Earth’s magnetic field of 0.5 Gauss transverse to the beam and a uniform shielding factor of 1000. What could possibly affect the measurement are time fluctuations of the ambient magnetic field, but assuming a relative variation of the magnetic field strength not greater that
and again a shielding factor of 1000, particle deviations of approximately 5 to 20 nm are expected for
K from 20 to 1 keV, i.e., smaller than the emulsion resolution.
In the configuration presented in
Figure 1, we have assumed that the only forces acting on the particle are the
E and
B fields in the Wien filter. Gravitation is of course present, but the overall vertical deflection over a distance
L of the order of 1 m is completely negligible (much less than 1 nm) for particles (electrons or protons) with keV energies. In principle, gravitation might play a role if there is a different response between particles and antiparticles to the Earth gravitational field in the Wien filter, since with a suitable rotation of the apparatus this may lead to slightly different velocities (and therefore de Broglie wavelengths) at the exit of the filter, but again this effect turns out to be negligibly small, and masked by the uncertainties in all relevant quantities entering Equation (
8).
In conclusion, it has been shown that interferometric methods can be used to obtain a direct estimate of particle/antiparticle masses. In particular, some systematics cancels out is the particle and the antiparticle mass are measured through the de Broglie wavelength in the same apparatus.
The method proposed here can be applied to any charged particle for its absolute mass measurement as well as to any particle–antiparticle pair for the measurement of their mass ratio. This, however, typically requires adjusting the interferometric parameters to the case under consideration.
For example, for the case of hadronic systems, like protons and antiprotons, one can note that spectroscopy has been used to estimate the proton-to-antiproton charge-to-mass ratio with a precision of 69 parts per trillion [
14]. In this regard, an interferometric measurement would instead depend only on the masses without having to rely on the equality of the charges.
This approach is made possible thanks to the availability of low-energy antiprotons at the new ELENA facility of the CERN Antiproton Decelerator [
33,
34]. For instance, the ASACUSA experiment [
35] is planning to extract a low-energy antiproton beam from its MUSASHI trap or from the planned Reservoir under construction [
36]. Energies at the level of 10 eV can be obtained and the availability of protons and antiprotons in the same beam source makes possible interferometric experiments with a de Broglie wavelength of 10 pm. This wavelength is about the same that was used (for positrons) in the QUPLAS-0 experiment. As the same beamline can accommodate both protons and antiprotons, an interferometric experiment can be performed along the lines outlined here.