1. Introduction
Entangled photon sources are critical for developing photonic quantum technologies [
1] and for photonic quantum information processing [
2]. These sources have also allowed for the experimental study of what the founding fathers of quantum theory called thought experiments [
3,
4]. As a concept, entanglement appears in physics after intense debate. The term (loosely translated from the German word
verschränkung) was introduced by Schrödinger [
5] to describe what occurs with our knowledge of two systems that are separated after they were interacting for a while, and from which we had maximal knowledge before the interaction [
6]. As a result, instead of two isolated systems, there is just a single composite system and therefore any change to one subsystem would affect the other, no matter the distance between them. The results obtained from interaction-free measurements [
7,
8,
9] are an indication that entanglement is indeed a fundamental property of quantum systems.
Bipartite entangled states can be prepared by producing an interaction between two different quantum systems in such a way that neither of the two emerging states has a definite value, but as soon as one of them is measured, the other state is automatically determined. In this context, the spontaneous parametric down-conversion (SPDC) process is a suitable way to produce entangled photon pairs. This occurs in nonlinear crystals, where one photon (pump) gives rise to a pair of entangled photons (signal and idler) [
10,
11,
12]. SPDC is degenerate if the wavelength of the signal and idler photons are equal; otherwise, it is non-degenerate. Depending on the direction of propagation of the pump, signal, and idler wave vectors, the SPDC process can be classified as collinear or non-collinear. The polarization of the new pair of photons characterizes the SPDC process as follows. In the type-I SPDC, the polarization of the created photons is parallel to each other and orthogonal to the polarization of the pump photon. The light created in these conditions forms a cone aligned with the pump beam. In the type-II SPDC, the idler polarization is orthogonal to signal one, and the new light forms two cones that are not necessarily collinear.
The type-II SPDC is particularly interesting as the photons produced are entangled in their polarization states [
13,
14], making them useful for representing qubits in quantum information [
15]. One of the cones is ordinarily polarized and the other extraordinarily. Since they intersect in most configurations, it turns out that the generated light that propagates along these intersections is not polarized since we cannot distinguish if a certain photon belongs to one or another cone (possible entanglement is anticipated). Nevertheless, ordinary and extraordinary photons propagate at different speeds inside the crystal [
16,
17], so one photon comes out of the crystal before the other one [
11]. Then, in principle, a time measurement can distinguish between the photon pairs along the intersections (meaning no entanglement) [
2]. One obtains quantum indistinguishability (entanglement) once the relative time ordering is compensated by using concrete arrays of crystals [
18]. In this way, the entire Bell basis of bipartite entanglement can be achieved in terms of the polarization state of the photon pairs produced by the type-II SPDC.
In general, SPDC follows the conservation of energy and conservation of momentum, which are crucial for the process to occur [
10,
11,
12]; the corresponding equations are called phase-matching conditions. In particular, conservation of the wave vector is required for an efficient non-linear effect, although it is an impossible condition to be satisfied with most materials [
11]. The above condition is commonly achieved in birefringent nonlinear uniaxial crystals since their refractive index for a given wavelength depends on the orientation of the electric field with respect to the optical axis (biaxial crystals—which have three mutually orthogonal principal axes associated with different refractive indices—are also available).
To solve the phase-matching conditions in vector form, it is convenient to work in spherical coordinates. Then, nine parameters are to be determined: three wavelengths (conservation of energy) and three pairs of polar and azimuthal angles (conservation of momentum). However, for light propagating within nonlinear crystals, depending on whether it is polarized ordinary, or extraordinarily, the refractive index is expressed in terms of both the wavelength and the angle formed by the wave vector and the corresponding optical axis [
16,
17]. This makes obtaining analytical solutions for phase-matching conditions a surprisingly difficult task, especially in the non-collinear case if one is looking for the production of entangled photon pairs.
As the refractive index of extraordinarily polarized light is an elaborated function of the unknowns, and the latter are encapsulated by trigonometric functions, determining the parameters requires solving strongly transcendental equations, a fact that has motivated the study of numerical approximations than the search for analytical solutions [
11,
19,
20].
In this work, we show that the difficulty of solving the strongly transcendental equations of vector phase-matching is reduced by transforming them into a fourth-order polynomial equation that admits an analytical solution. The corresponding roots are complex-valued in general, so we impose a reality condition that determines the optical axis orientations that are useful for efficient down-conversion. Our research addresses the type-II SPDC process in nonlinear uniaxial crystals, including type-I SPDC as a particular case, with emphasis on the non-collinear case.
The usefulness of the analytical solutions reported here is twofold: they contribute to a better understanding of the SPDC process by expanding the set of exactly solvable cases, and are helpful in the design of entangled photon sources.
To provide a practical example we consider the nonlinear crystal beta-barium borate (BBO), which is negative uniaxial (although the approach is not restricted to such a crystal. Other examples include lithium niobate (LNB) and quartz, which are negative and positive uniaxial crystals, respectively). Our results are in complete agreement with theoretical and experimental work already reported by other authors and include some refinements whose full experimental verification remains an open question.
The remainder of the paper is organized as follows. In
Section 2, we introduce some basic notions of the phase-matching conditions and establish the problem to be solved. The vectorial conditions for phase-matching are simplified to a system of two coupled scalar equations for the polar angles of idler and signal photons. For type-II SPDC, these equations are transformed into a fourth-order polynomial equation whose solutions provide the polar angle of the idler beam. In
Section 3, we provide the exact solution for the equation and particularize it to the SPDC process in a BBO crystal. We analyze both degenerate and non-degenerate cases. Five general configurations of the cones of down-converted light are discussed, they include beam-like, divergent, osculating (entanglement in collinear beams), overlapping (entanglement in spatially separate beams), and coaxial cones. In
Section 4, we discuss our results by comparing them with the work of other authors. Our theoretical model is in close agreement with experimental measurements and theoretical approaches already reported in the literature. Finally,
Appendix A includes some concrete calculations that are useful to follow the discussion throughout the manuscript.
2. Laws of Conservation for SPDC
The frequency-matching and phase-matching conditions of spontaneous parametric down-conversion (SPDC) are, respectively, written as
where
and
are the angular frequency and wave vector of the
u-light wave, with
, referring to pump, signal, and idler fields.
The conditions (
1) arise from the temporal and spatial phase matching of the waves associated with the three fields in SPDC phenomena, and ensure the mutual interaction of the fields over extended durations of time and regions of space [
17]. In general, they lead to multiple solutions where the down-converted light takes the form of a cone of multispectral light [
17].
We are interested in finding exact solutions to the phase-matching condition for both types of nonlinear uniaxial crystals, I and II, and for two general cases (degenerate and non-degenerate) of the frequency-matching condition. That is, our program will hold for any relationship between the angular frequencies, whenever they satisfy the frequency-matching (
1). In this form, we shall assume that the values of
,
, and
are available from either direct measurements in the laboratory or appropriate theoretical considerations.
The reference system in the laboratory is defined by the Cartesian unitary vectors in
:
,
, and
. The coordinates are right-handed, with axes
,
and
. The origin of the coordinates is located at the center of mass of the crystal, which will be considered a rectangular cuboid for simplicity, see
Figure 1. The principal optic (dielectric) axes are defined by the unitary vectors
in such a way that
and
are parallel. Thus, the laboratory and crystal frames are related by a rotation
around the common
y-axis.
Without loss of generality, we will assume that the optic axis of the crystal is oriented according to the unitary vector
, with
, see
Figure 1. Additionally, we shall consider that the pump-light wave propagates along the
z-axis. The relationship between the principal optic (dielectric) and crystallographic axes, respectively defined by the vectors
and
, is shown in
Figure 2. Note that
and
are parallel to
.
In general, to satisfy the phase-matching condition (
1), the wave vectors
obey the parallelogram rule of vector addition. Then we talk about
vector phase-matching. However, depending on the applications of the down-converted light, one might be interested in studying only those vectors
that satisfy the additional condition of being collinear
, with
a unitary vector in
. In such a case, we talk about
scalar (or
collinear)
phase-matching. Our approach faces the problem in general (vector) form. Once this is solved exactly, we particularize to the simplest (scalar) form by adjusting the parameters of the general solution.
The down-converted light is expected to form cones whose vertices lie inside the crystal. For the sake of simplicity, we shall assume that all vertices coincide with the origin of coordinates in the laboratory frame.
Therefore, using spherical coordinates, the wave vectors are written as follows
where
and
stand for the polar and azimuthal angles, respectively, and
refers to the wave number of the
u-light wave, see
Figure 3.
The problem is to determine the wave numbers
,
, as well as the angles
,
, and
,
, such that the phase-matching (
1) is satisfied by giving
,
, and
(remember that we are assuming frequency-matching is assured).
Introducing (
2) into the phase-matching (
1) leads to the system
From (
3) one immediately obtains
, which means a
-shift between the azimuthal angles
that defines the relationship between the polar angles as follows
The roots of the system formed by Equations (
4)–(
6) ensure the conservation of linear momentum in the SPDC process.
On the other hand, for uniaxial crystals with ordinary and extraordinary refractive indexes,
and
, to describe the propagation of ordinary light we require only the frequency-dependent refractive index
. However, for extraordinary light waves, the refractive index depends also on the angle
formed by the wave vector and the optic axis according to the expression [
17]
The indexes
and
are determined by the Sellmeier Equations [
16,
17].
Remark that Equation (
7) introduces additional degrees of freedom to the problem we are dealing with. Indeed, each of the three waves of light can be ordinary or extraordinary. Then, according to the polarization of the
u-wave, the refractive index
depends on the angle
that is formed by the wave vector
and the optic axis. Using the inner product of
with the unitary vector
that characterizes the optic axis one has
Then
, and
That is, the angle formed by the idler and signal beams with the optic axis depends on
as well as on the phase-matching angles we are looking for.
Therefore, according to the polarization of idler and signal waves, the refractive index for these waves could depend on
and the corresponding phase-matching angles. If the polarizations of both light waves are equal (orthogonal) then the SPDC phenomenon is of type I (II) [
17]. We are going to solve exactly the phase-matching for both types.
The number of unknowns in Equations (
4) and (
6) can be reduced by expressing the wave numbers
in terms of the frequency and refractive index
where
is the speed of light in a vacuum. Therefore,
so we just need to determine the angles
and
(remember that
is the
-shifted version of
). That is, we simplified the vector phase-matching (
1) to the system of scalar equations composed of (
5), (
10) and (
11). They, together with the frequency-matching condition (
1), must be simultaneously satisfied.
However, by reducing the number of unknowns we increase the complexity of the problem because, according to Equation (
7), the relationship between the refractive index
and the angle
is not only quadratic but transcendental for extraordinary
u-waves. In turn, Equation (
8) connects
with the unknowns
and
in transcendental form, no matter the polarization of the
u-wave. Then, depending on the polarization of the down-converted waves, the system (
10) and (
11) could include transcendental equations of at least second degree.
Clearly, solving the pair (
10) and (
11) requires concrete information about the character of the fields as they propagate in the crystal. For clarity, we shall analyze the phase-matching of types I and II separately.
2.1. Type-I SPDC
For nonlinear uniaxial crystals of type I, the idler and signal fields are polarized in the ordinary form. We write
and
for the respective refractive indexes. In turn, the polarization of the pump field is extraordinary, so the refractive index is a function of
(the angle between
and
), written from (
7) as follows
Thus, when the pump beam enters the crystal forming the angle
with the optical axis, the extraordinary index will be different for different values of
.
The function
is positive for any value of
, and satisfies
With (
12), Equations (
10) and (
11) acquire the form
Squaring both equations of (
13), after some simplifications, we obtain
The signal angle
is derivable from (
14) and the second equation of (
13).
In the degenerate configuration (
), the above results are simplified as follows
Thus, the light produced by (degenerate) type-I SPDC describes a right circular cone, the axis of which is along the propagation direction of the pump beam, with aperture
(inside the crystal). In addition, the
-shift between azimuthal angles (
5) means that the created photon pairs are emitted on opposite sides of the corresponding cone.
2.2. Type-II SPDC
In the case of nonlinear uniaxial crystals of type II, consider the situation in which the signal field is ordinarily polarized. The pump field is still associated with the refractive index (
12), and the idler field is now linked to the function
which is positive for any value of
fulfilling (
8), and satisfies
Using (
15), Equations (
10) and (
11) are rewritten as follows:
After squaring (
16) and (
17), we may solve the system by preserving
. The straightforward calculation gives rise to the quadratic form
Our program is completed after solving the transcendental Equation (
18) for the phase-matching angle
.
In the previous sections, we emphasized that solving equations, such as (
18), is much more difficult than it seems at first glance. Indeed, according to (
15), the refractive index
is a very elaborated function of
, so (
18) is strongly transcendental. This fact could motivate more the study of numerical approaches than the search for analytical solutions [
11,
19,
20]. However, we are going to show that the complexity of solving (
18) is reduced by transforming it into a fourth-order polynomial equation.
Fourth-Order Polynomial Equation for Type-II SPDC
To simplify the calculations, it is useful to square (
8) in the form
where
Then, the refractive index (
15) can be expressed as follows
with
In turn, (
18) can be simplified in the form
where
To avoid the square root appearing in
, let us square (
21) to arrive at the following quartic form for
,
From (
19), it is clear that (
22) is indeed a fourth-order polynomial equation in the variable
The straightforward calculation yields
where the coefficients
,
, are real-valued functions of the azimuthal angle
, the orientation
of the optic axis, and the three angular frequencies
,
,
, see
Appendix A for details.
3. Exact Solution of the SPDC Phase-Matching Conditions for Crystals of Type II
The complete solution to the vector part of Equation (
1) for nonlinear uniaxial crystals of type II is obtained after solving (
24). Indeed, we determine the polar angle
by reversing (
23) with
the appropriate root of Equation (
24). The other polar angle
is obtained from either (
16) or (
17). In turn, as indicated above,
is uniquely determined by
through the
-shift (
5).
The fourth-order polynomial Equation (
24) is better studied in its monic form
with
,
. In these terms, the four roots are as follows
where
and
is a root of the cubic equation
with
For a detailed derivation of the previous formulae see
Appendix A.
Refraction. The results obtained above (and in the previous sections) refer to light propagating within the crystal. A more realistic model should consider that the detection zone is far from the crystal, where the light to be detected has undergone refraction. That is, we have to take into account the transition from the crystal to the medium in which the detectors—and the crystal itself—are embedded. For simplicity, we will suppose the down-converted light to propagate in the air () as soon as it leaves the crystal.
Assuming that the normal to the interface is parallel to
, see
Figure 1, for type-II SPDC the Snell law yields
where
and
are the polar angles of refraction for signal and idler waves, respectively. From Equation (
17), one immediately obtains
Therefore, after refraction, the relationship between the polar angles of down-converted light is uniquely determined by the way in which the frequency-matching () is satisfied.
In particular, for degenerate frequencies , one has . That is, if the down-converted light is produced in degenerate form, signal and idler cones will be observed with the same inclination with respect to the pump beam, and will have the same aperture. Other combinations of and fulfilling the frequency-matching lead to different configurations of the cones at the detection zone, as we are going to see.
In the sequel, we will emphasize the predictions after refraction since they are the subject of interest for experimental data in the laboratory.
Without detection, the down-converted cones extend infinitely far. Their conical surfaces are formed by half-lines (generatrix lines) whose orientation is determined by the wave vectors and .
Detection plane. Positioning a transversal detection plane at , with L the crystal length, the directrix (base) of each cone is defined by the intersection with . The lateral surfaces are then formed by line segments (generatrix lines) that are oriented according to and . Therefore, in the laboratory, the most general configuration of each cone is oblique circular, where the axis is not orthogonal to the base (a circle), so the base center does not coincide with the projection of the apex on . As we are going to see, right circular cones are also allowed, but they require a very concrete orientation of the optic axis as well as particular configurations of the frequency-matching.
We assume that it is feasible to operate with detectors that can be placed (and moved) along the detection plane
, which is indeed a displaced version of the
-plane of the laboratory frame shown in
Figure 1. The plane
is where the transverse patterns of both cones are to be formed.
BBO crystal. To provide a practical example we will consider the nonlinear crystal beta barium borate (BBO,
), which is negative uniaxial
and is characterized by the wavelength-dependent refractive indexes [
16,
17]:
The Sellmeier Equations (
29)–(
30) consider refractive indexes at room temperature, with wavelengths
measured in
m, and are valid in the wavelength range (0.22–1.06)
m [
17]. The ordinary refractive index (
29) is larger than the extraordinary one (
30) at any allowed wavelength
.
Using a BBO crystal in the laboratory, the phase-matching of both types I and II can be achieved by tuning the angle formed by the optical axis and the pump beam, so this crystal is suitable for testing our theoretical results.
The BBO crystal belongs to the symmetry group 3m [
16,
21,
22,
23,
24]. Considering the second-order nonlinear coefficients
for this group, the straightforward calculation yields three different expressions for the effective nonlinearity
of BBO crystals. For type-I BBO, taking into account the anisotropy of the down-converter and the allowed polarizations of the medium, we obtain
where
and
stand for the ordinary and extraordinary relative dielectric constants of the medium, with
and
the extraordinary and ordinary refractive indexes for the
u-wave. The three-index notation
designates the polarization of idler, signal, and pump waves in that order. At the limit
, up to a global
, we have
In turn, for type-II BBO, we arrive at the formulae
and
At the isotropic limit
, the above expressions become
and
The polar and azimuthal angles are measured with respect to the crystal reference frame, where the optical axis is along the corresponding z-axis.
The above expressions for the effective nonlinearity of BBO crystals refer to the vector phase-matching, where the wave vectors
obey the parallelogram rule to satisfy the vector addition (
1). To our knowledge, Equations (
31)–(
36), have not been previously reported.
In contrast, what is well-known is the calculation of the effective nonlinearity for scalar (or collinear) phase-matching. In this case, the three pairs of angles
satisfy
and
. Introducing these values into (
31), (
33) and (
34), yields simplified expressions. Attending the isotropic case, Equation (
32) acquires the form
while both (
35) and (
36) are reduced as follows
Equations (
37) and (
38) were first reported in [
22], and then included in the reviews [
16,
23]. Here, they are recovered as particular cases of our results (
31)–(
36).
In general, the effective nonlinear coefficient
is useful to calculate quantities, such as the conversion efficiency
, whose formulas often involve
instead of the coefficient itself, see for instance Tables 2.28 and 2.29 in [
16].
Assuming that factors, such as group-velocity mismatch, dispersive spreading, and diffraction can be neglected, the plane-wave fixed-field approximation yields expressions of
that are proportional to the pump power density
, the square of the crystal length
L, and the “quality parameter”
, with
the refractive index of the
u-light wave [
16] (an additional factor can be included to consider the effect of the wave mismatch on the conversion efficiency). However, convertible radiation is not a plane wave in real frequency converters, so the accurate calculation of
is very complex. Analytic expressions of
are feasible only for some special and simple cases.
Pump wavelength. Our approach is based on exact solutions to the vector phase-matching conditions (
1), so it is not constrained to a particular value of the pump wavelength
. In practice, the choice of
is made in combination with the characteristics of the down-converter crystal, taking into account the wavelength of the light produced in the SPDC process (since it defines the profile of the photodetectors to be used). For example, assume that down-converted light is created in a degenerate configuration. Centering the pump wavelength at
nm (violet light) we have that the photon pairs are created at
nm (infrared light). Violet laser and infrared photodetectors are commonly used in virtually any quantum optics laboratory [
25,
26]. The latter makes
nm very useful as a test pump wavelength in our model, so we will use it as a prototypical example.
Next, we are going to analyze the situation in which a type-II BBO crystal is pumped by a violet laser diode that operates at nm. Configurations for other admissible values of the pump wavelength (equivalently, the pump angular frequency ) are feasible from our general solutions.
3.1. Degenerate Case
Throughout this section, we assume that down-converted light is created in degenerate form (
). As noted above, in this case, the Snell law (
28) leads to the identity
. Consequently, after refraction, the signal and idler cones have the same aperture and inclination with respect to the pump beam when
, as observed in the laboratory.
We have already indicated that the roots are functions of , , and the three angular frequencies . Hereafter, we use the shorthand notation , , with implicit dependence on the angular frequencies.
3.1.1. Delimiting The Orientation of the Optic Axis
In general, the functions are complex-valued. However, only real-valued functions can be directly associated with angles that are measured in the laboratory. Therefore, as the condition is mandatory, we have to differentiate the values of that produce real-valued functions from those that give rise to with non-zero imaginary part.
To obtain insight into the matter, consider the functions
defined by
. They are depicted in
Figure 4 for
, with a close-up of the vicinity where the imaginary part of
is equal to zero,
Figure 4a. We identify two complementary intervals,
and
, where
and
, respectively. Other values of
yield
and
, with
the complex conjugate of
. Therefore, in the present case, the orientation
of the optic axis must be confined to the interval
, see
Figure 4b.
In general, the dependence of
on
and
is obtained through the set
, after reversing Equation (
23). Following the shorthand notation introduced above we write
, remember that the dependence on the three angular frequencies
is implicit. To facilitate the analysis of
let us consider in detail the situations defined by
first, and then by
.
fixed. The expression
provides an ellipse parameterized by
.
Figure 5 shows the ellipses
obtained for some representative values of the azimuthal angle
.
Figure 5.
Given , the polar angle describes an ellipse parameterized by . All the angles are measured in sexagesimal degrees, and are considered before refraction. Black, red, blue, and purple paths stand for , and respectively (a). The paths of medium thickness in black and gray correspond to and (b). For , the vertices are at the points and , with maximum and minimum located at and , and crossing points at and . The ellipse defined by is a counterclockwise rotated version of that generated by .
Figure 5.
Given , the polar angle describes an ellipse parameterized by . All the angles are measured in sexagesimal degrees, and are considered before refraction. Black, red, blue, and purple paths stand for , and respectively (a). The paths of medium thickness in black and gray correspond to and (b). For , the vertices are at the points and , with maximum and minimum located at and , and crossing points at and . The ellipse defined by is a counterclockwise rotated version of that generated by .
The points on the ellipse
are in a one-to-one relationship with the intersections of the cone of idler light and the plane
. The absence of intersections implies that there are no real angles
derivable from the roots (
26) for the orientation
, and vice versa. In the detection plane
, depending on the number of intersections, the condition
results in either a tangent or a secant to the transverse pattern formed by idler light. The former case refers to a single intersection while the latter refers to two intersections. This identification is clearly associated with the fact that the ellipses
provide at most two real angles
for each
in
.
Observe the symmetry between the ellipses for
and
in
Figure 5b. As they verify
, it is clear that the entire set of points on a given ellipse
is redundant.
The intersections occurring on the positive semi-axis of are in one-to-one correspondence with those occurring on the negative semi-axis of , and vice versa. Since these lines are one -rotated version of the other, we realize that both of them provide twice the same information, up to the phase . Similar conclusions are obtained for any other line and its -rotated version.
To eliminate redundancies, we will take the convention of counting only the intersections associated with nonnegative values of for each line . In this way, the information provided by and is complementary: the values that are not counted for are recoverable from the values counted for (after a change of sign). Our convention is consistent with the fact that polar angles are formally nonnegative.
All the points on a given ellipse
constitute the exact solution of the problem for
. With the convention introduced above, no one of these points is discarded. The complete determination of the polar angle of idler light is obtained by exhausting all the values of
, which can be done by taking line
and rotating it counterclockwise around the
z-axis while counting intersections with the transverse pattern of idler light, see
Section 3.1.3 for details.
The ellipses defined by and are of major relevance since they refer to the intersections of idler light and the -plane for each admissible value of . As the idler cone is centered along the x-axis, the set that we have delimited from such ellipses contains all the values of for which the cone of idler light exists. The ellipses defined by other values of are associated with different subsets of . In this sense, and serve as envelopes of the set .
For
, the difference
of the corresponding polar angles provides the aperture of the cone.
Figure 6a shows
as a function of
. We can also characterize the orientation of the idler cone axis in terms of
. In
Figure 6b, we appreciate that the cone axis is located at the positive semi-axis
for
, and it transits to
for
. At
, the cone axis coincides with the pump beam.
fixed. The angular dependence
is illustrated in
Figure 7 for representative values of
in the set
. The presence of lobes (red and black paths in
Figure 7) means that
is real only for particular subsets of the azimuthal domain
at the corresponding
. Consistently, the transverse pattern of idler light will be entirely contained in either semi-plane
or
of the detection plane
. In turn, the continuous curves shown in
Figure 7 represent cones of idler light whose transverse pattern occupies both semi-planes of
. Concrete configurations are discussed as examples in the next sections.
Figure 7.
Angular dependence for (black and red lobes), and (blue and purple curves). The lobes are associated with cones of idler light waves that describe circles entirely contained in either semi-plane or of the -plane. Continuous curves represent cones that describe circles occupying both semi-planes of the -plane.
Figure 7.
Angular dependence for (black and red lobes), and (blue and purple curves). The lobes are associated with cones of idler light waves that describe circles entirely contained in either semi-plane or of the -plane. Continuous curves represent cones that describe circles occupying both semi-planes of the -plane.
In order to correctly delimitate the angle , we have to impose the condition . Then, it is appropriate to consider the decomposition .
According to our convention, the set
is not taken into account for
since
yields only negative values of
,
Figure 8. In turn, from
Figure 8a, we appreciate that
provides two different values of
for each value of
, with exception of the vertices. This two-fold property of
is associated with the lobes shown in
Figure 7. On the other hand, for
, the polar angle
can be operated as a function of
. The latter is connected with the continuity of blue and purple curves in
Figure 7.
Therefore, for we formally constraint the orientations of the optical axis to the set . However, we have to keep in mind that the set provides the orientations of the optical axis for which the idler cone exists either in or .
3.1.2. General Configurations for Down-Converted Light
Keeping in mind that our approach is based on exact solutions, the next qualitative profiles of the down-converted light hold for any admissible value of the pump wavelength , other than the violet one ( nm) used as a generic example throughout this work.
For
, the vertices of the ellipse
yield
. These points correspond to the situation in which the cone structure of idler light degenerates into a single beam. This phenomenon has been already described and measured in the laboratory by other authors [
27,
28,
29,
30] but, as far as we know, its connection with the vertices of
has been unnoticed in the literature.
At the crossing points with the
-axis, the polar angle
defines a generatrix of the idler cone that is collinear with the pump beam. From Equation (
17) we realize that
implies
, so there is also a generatrix of the signal cone that is collinear with the pump beam. The coincidence of these two generatrices with the pump beam configures the down-converted cones in
osculating form, where the cones touch along the common generatrix (
) and are tangent to each other.
From (
2) we obtain
and
, so these wave vectors, together with
, satisfy the scalar (collinear) phase-matching. The latter has motivated the osculating configuration to be known as collinear [
30,
31,
32,
33], but it should be emphasized that not all wave vectors integrating the down-converted cones satisfy the scalar phase-matching. This is true only for wave vectors along the generatrices that coincide with the pump beam, so the term “collinear” would be a misnomer for this configuration.
For , the cone axis of idler light coincides with the pump beam while the cone aperture is maximum. The same holds for the signal cone, so it overlaps exactly with the idler cone after refraction. In this case, the down-converted cones are right-circular and, together with the pump beam, form the coaxial configuration.
It is important to mention that
reduces the fourth-order polynomial Equation (
25) to the bi-quadratic form discussed in
Appendix A. Therefore, the coaxial configuration is the simplest and most symmetric profile of the down-converted cones derivable from the quartic Equation (
25).
Remarkably, for
, the authors of [
15] indicate that “no down-conversion takes place at this setting” since “the actual down-conversion efficiency in a uniaxial crystal such as BBO varies as
[22]”, where
is the angle between the crystal optic axis and the pump beam (in our notation
), and [22] corresponds to the first edition of our reference [
16].
However, in the previous section, we pointed out that such statement is not entirely accurate. To be concrete, using (
12) and (
15), the quality parameter for type-II BBO (e → e + o) acquires the form
recall that
and
are the extraordinary and ordinary refractive indexes for the
u-wave. A similar expression is obtained for the other distribution of polarizations in type II BBO (e → o + e).
Equation (
39) is consistent whenever the effective nonlinearity
, originally calculated in terms of the angles
in the crystal, is expressed in terms of the laboratory angles
. The transformation is obtained through the rotation
of the wave vectors
, which gives rise to the relationships
where
, so that
and
. Then, the most generally effective nonlinearity (
33) is rewritten as follows
Using (
40) and (
41), the introduction of (
42) into (
39) shows an elaborated dependence of
Q on
(remember,
depends on
and
, while
depends on
,
, and
). Nevertheless, for
, the straightforward calculation yields
with
, see Equation (
8), and
where we have used (
5). The values of
and
at
are derivable from our exact solutions, see for instance
Figure 5.
As the azimuthal angle
does not depend on
, the expression provided in (
43) is indeed a function of
and the angular frequencies
,
, and
. It reaches its maximum at
, and is equal to zero for
.
That is, for vector phase-matching, with , the production of down-converted light is not only different from zero but optimized along the x-axis.
Accordingly, the conversion efficiency
is different from zero within the plane-wave fixed-field approximation, where
Q is included as a factor in the formula of
[
16]. Other approaches leading to
must also include
Q as a factor in such a way that the result is reduced to that of the plane-wave fixed-field approximation in the appropriate limit.
The situation changes for scalar phase-matching. Indeed, making
and
in (
33), and introducing the result into (
39), we arrive at the anisotropic quality factor
Similarly, from (
34) and (
39) we obtain
As far as we know, Equations (
44) and (
45) have not been previously reported in the literature. At the isotropic limit (
) they coincide and provide the expression
Note that the quality parameter (
46) describes only the idler and signal waves that have their wave vector aligned with the pump beam. In such a case, the situation is even more dramatic than anticipated in [
15], where the efficiency is announced to vary as
.
Nevertheless, above, we have found that, for
, the down-converted light is produced in right-circular cones of maximum aperture, whose axes are aligned with the pump beam. That is, no generatrix of any of the cones coincides with the pump beam if
, so neither
nor
is collinear with
. In this sense, the quality parameter (
46) shows that no down-converted light is produced such that its wave vector is aligned with the pump beam for
, but it does not mean that down-converted light is not produced when the optical axis is tilted at
.
Therefore, unlike the negative statement made in Ref. [
15], we have shown that the conversion efficiency of type-II BBO crystals is different from zero at
. Moreover, the production of down-converted light is optimized along the
x-axis at the setting we are dealing with.
3.1.3. Geometric Distribution of Down-Converted Light for nm
As indicated above, our approach provides exact solutions for any admissible value of the pump wavelength . Centering it at nm provides a concrete and practical example where the degenerate production of photon pairs yields the infrared wavelength nm. The results presented below provide quantitative information about the distribution of down-converted light for such a value of the pump wavelength. The qualitative behavior of the solutions is basically unchanged for other admissible values of .
Let us discuss in detail the configurations mentioned in the previous section, together with two additional settings that are relevant in practice, for a pump beam with nm. They are classified according to the values of the optical-axis orientation as this sweeps from left to right.
Beam-like configuration. For
, one has
at
, see
Figure 6 and
Figure 8, so the idler cone is deprived of structure and degenerates into a single beam that forms the angle
(before refraction) with the pump beam. As a transverse pattern, the idler beam depicts a single spot on the positive semi-axis
of
. Consistently, the transverse pattern of the signal cone is a single spot on the negative semi-axis
. These spots are equidistant from the origin. Our results are in complete agreement with theoretical and experimental works already published by other authors [
27,
28,
29,
30].
Divergent cones. For
, the axes of idler cones diverge from the axis of the corresponding signal cone. The transverse pattern is formed by two separate rings that are centered along the
x-axis; the idler ring is entirely contained in the first and fourth quadrants of
, while the signal ring is in the second and third quadrants. Inside the crystal, the centers are not equidistant from the origin
. After refraction (outside the crystal),
, with
, so the axes of both cones are now equidistant from the pump beam. Our results are in complete agreement with previous studies, see for instance [
30].
Figure 9 illustrates the case for
. Remark that the polar angle
is positive in the vicinity of
(and
), see
Figure 9b. In turn, the polar angle
of the signal beam is positive around
, see
Figure 9c. For other values of the azimuthal angles, there is no real solution for the polar angles.
The lobes described by
as a function of
are justified as follows. Let us measure the cone aperture of idler light in terms of
, see the red rings in
Figure 9a. Considering that
runs counterclockwise, we can start by tracing a half-line along the positive semi-axis
of
, with the left edge fixed at the origin. We find two intersections between the half-line and both red rings. These intersections correspond to the points on the left semi-lobe at
, see
Figure 9b. Tilting the half-line towards the positive semi-axis
, the intersections collapse into a single one at
, where the half-line is tangent to the ring and the left semi-lobe is completed. Increasing the value of
, the half-line finds nothing up to
, where the lower part of the red rings is found (and the right semi-lobe starts). We exhaust the search of intersections by tilting the half-line toward the positive semi-axis
. The blue lobe described by
in
Figure 9c admits a similar description.
With the previous description, it is clear that the negative values of the polar angles (lobes in black and dashed-gray) in
Figure 9b,c also describe the rings shown in
Figure 9a, but in a reference system that is rotated by
around the
z-axis. This symmetry has been discussed above, where we have introduced the convention of considering only nonnegative values of
. The lobes in black and dashed-gray shown in
Figure 9 reproduce
in reverse order (with
sweeping
from right to left), after a change of sign. In this form, we remark that all the real roots (negative and nonnegative) found in the previous sections are useful to describe the SPDC phenomena.
Osculating cones. For the right edge of
, i.e.,
, we obtain
, which defines a generatrix that is collinear with the pump beam. This result is in complete agreement with the so-called “collinear configuration” studied in references [
30,
31,
32,
33], for instance.
The setting is illustrated in
Figure 10. Similar to the previous case, the cone apertures
are in correspondence with finite intervals of
, but now the down-converted light is produced in a pair of osculating cones.
As we have seen, positioning the crystal such that the angle formed by the optical axis and the pump beam is in the set , we recover three different configurations of the down-converted light that are recurrently studied in the literature.
It is important to emphasize that the width of
is only
, so it seems challenging to align the optical axis with the appropriate precision to distinguish between the configurations associated with the extremes of
, and that linked with any other
. Namely, great precision is required to achieve the beam-like (
), divergent (
), and osculating (
) configurations in the laboratory. Fortunately, in practice, this is not a major problem. For instance, in [
30] it is reported a series of experimental studies where beam-like, osculating (collinear), and “non-collinear” configurations are compared. The pump laser was a 408 nm cw diode laser, and the SPDC photons had a central wavelength of 816 nm. For the osculating configuration, the angle
(in our notation) was reported, while the beam-like was accomplished by reducing the angle to
. These values of
define an interval of width
, which is very close to the width of
mentioned above. That is, it is feasible to achieve the precision required to experimentally produce the configurations we are dealing with.
Remember that although we are discussing the consequences of pumping light at
nm into a BBO crystal, our exact solutions allow considering any admissible value of
, in particular
nm as this was used in [
30]. Concrete examples are discussed below.
In addition to the previous configurations, two additional settings are feasible if . They are as follows:
Overlapping cones. Given , the polar angle is different from zero for any value of in both down-converted cones. The latter means that the cones overlap by preserving their centers along the x-axis. The larger the value of , the shorter the distance between the centers.
The overlapping configuration is illustrated in
Figure 11a for
, it is also classified as non-collinear, see for instance [
15,
30]. The points of intersection deserve special attention since they identify maximally entangled states [
10,
11,
12,
13,
14,
15].
Coaxial configuration. For
, the axes of the down-converted cones are along the
z-axis. Thus, the axes of the idler and signal cones are aligned with the pump beam, so these three waves of light form the coaxial structure shown in
Figure 11b.
To conclude this section, notice that the complementary set reproduces the overlapping and osculating configurations in reverse order: the larger the value of , the longer the distance between the centers. In this sense, we can take as the definite set of optic-axis orientations producing type-II SPDC in the different configurations discussed above.
3.2. Non-Degenerate Case
The exact solutions
introduced in Equation (
26) can be used with the down-converted frequencies rewritten as
and
. To obtain nonzero frequencies within the frequency-matching regime, the parameter
is restricted to the interval
. Using this notation we also write
and
for the related wavelengths.
Degenerate frequencies are recovered at . For , we have non-degenerate frequencies fulfilling frequency-matching. However, very low frequencies arise at or , so excessively long wavelengths would be calculated for down-converted light in a given crystal.
The latter shows that not all possible combinations of and that add up to lead to appropriate results. Therefore, we must further restrict the values of . The key to refining this parameter is provided by the intrinsic properties of the crystal under study. In fact, uniaxial nonlinear crystals operate in a very specific range of wavelengths that is defined by Sellmeier Equations. We will take full advantage of this property to define .
The down-converted frequencies that obey both the frequency-matching and the restrictions due to the intrinsic properties of a given crystal define the variability of the non-degenerate case. In general, the configurations calculated for converted light of degenerate frequencies are affected when , both in the aperture of the cones and in the arrangement of their axes. The greater the difference between and , the more noticeable the changes.
One of the reasons for studying non-degenerate frequencies is that real crystals are imperfect. We know that even when they are designed to produce converted light at degenerate frequencies from a pump frequency , the frequencies of the resulting light are centered at and sweep over a range of values whose width is usually inversely proportional to the quality of the crystal, but is never equal to zero.
Assuming that the bandwidth of the converted frequencies is defined by , it is immediate to see that the conical surfaces of converted light are not indefinitely thin, but have a structure whose width is determined by . The transverse patterns observed in the detection plane are rings whose widths are also determined by . Therefore, in order to have a realistic description of down-conversion, our model also takes into account these variations from the ideal case.
To investigate the properties of the non-degenerate case, we will focus on BBO crystals and pump beams at nm as examples. However, we must insist that our theoretical model is exact and general, so it is useful to study any other uniaxial crystal and other pump wavelengths.
For BBO crystals, the Sellmeier Equations (
29) and (
30) are valid for
in the range (220–1060) nm. Demanding the wavelengths
and
to be in such a range we obtain
. Therefore, the range of permissible wavelengths for down-converted light is (655.4198–1060) nm, the results are shown in
Figure 12. Equivalently, the permissible down-converted frequencies are in the range (0.382–0.6179)
.
With and in their permissible range, the polar angle presents some particularities that are not evident when looking only at the degenerate value . In particular, one finds a close relationship between the optical axis orientation and the converted frequencies that affect the production of converted light, even to the extent of canceling the down-conversion. This accounts for the sensitivity to alignment between the optical axis and the pump beam found in the laboratory when producing down-converted light.
Figure 13 shows the ellipses
in the range of permissible down-converted frequencies derived above. To compare with the results presented in the previous section, we have taken
(divergent),
(osculating),
(overlapping), and
(coaxial). In this form, the plots shown in
Figure 13 represent the polar angle
in the
-plane of the laboratory frame, as a function of the non-degenerate variability
. The results found in the previous section for
are recovered when
. The ellipses
for other values of the azimuthal angle
behave in a similar form.
The behavior of the blue and red ellipses is particularly striking since they run out almost as soon as . This means that converted light occurs at most with frequencies slightly above the degenerate frequency when the optic axis is tilted at or . Let us analyze these cases separately.
Assuming the optic axis is at
(blue curve), from left to right in
Figure 13, the intersection of the ellipse and the
-axis occurs at
, while the vertex is defined by
. The latter is the upper bound of permitted frequencies
in this case. The idler light transforms from an osculating to a divergent configuration, and then to a beam-like configuration as
goes from
to the degenerate value, and then to the maximum value
.
If all the frequencies between and are in the bandwidth , then the above configurations could not be distinguished from each other. For narrow enough bandwidths, some or all of these configurations could be studied separately. Therefore, the transverse pattern (a disk or a ring) will depend primarily on how narrow is the bandwidth of a given crystal. The only exception is the beam-like configuration since its transverse pattern always forms a disk. Of course, other factors include the technical ability to align the optical axis with respect to the pump beam.
Equivalently, tilting the optic axis to , the key frequencies are the degenerate and , which is now the upper limit. The transformation of the idler light settings is quite similar to the previous case, but now from to . The discussion about the distinguishability of the configurations is the same.
As we can see, non-degenerate frequency-matching includes some subtleties that defy experimental skills. High precision is required to measure the orientation of the optic axis, as well as crystals characterized by a very fine bandwidth to distinguish between osculating, diverging, and beam-like configurations.
The sensitivity of divergent and osculating configurations is not present in overlapping and coaxial settings, where deviations from the degenerate frequency involve only smooth variations of
, see curves in black and purple in
Figure 13. This stability allows a better investigation of the behavior of down-converted light beyond the ranges that characterize the imperfection of crystals.
Figure 14 shows the geometric distribution of down-converted cones for
and three different values of
. Compared with the case of degenerate frequencies shown in
Figure 11a, the cones do not have the same aperture. In fact, when
is increased, with respect to the degenerate value, the centers of the circles are closer while the aperture of idler cone decreases. Consequently, the intersection points define a segment of line that is parallel but not coincident with the
y-axis, and the distance between such points is shortened.
From
Figure 12, the wavelengths of down-converted light in
Figure 14a are
nm and
nm. Similarly, in
Figure 14b they are
nm and
nm, while
Figure 14c refers to
nm and
nm.
According to our previous discussion, each of the above configurations could be at the center of a bandwidth, so its transverse pattern would form a ring. If by any chance the frequencies of the three configurations shown in
Figure 14 are in the same bandwidth, then these configurations are part of the same ring. The same conclusions hold for the cones of signal light (blue circles) shown in the figure.
4. Discussion of Results and Conclusions
Throughout the previous sections, we have taken nm as the prototypical wavelength of a pump beam that is injected into a BBO crystal to produce down-converted light. Under degenerate frequency-matching, down-converted light occurs at nm, as is well known. In practice, such a light pump is generated by a violet laser while the down-converted photons are collected on infrared photo-detectors somewhere in front of the crystal.
However, nm is not the only useful wavelength for this purpose. Other commonly used wavelengths are, for example, nm and nm. Our theoretical model leads to correct results for these and other wavelengths that produce parametric down-conversion in nonlinear uniaxial crystals in general, and in BBO crystals in particular.
Figure 15 shows the polar angle of idler light for
nm, at
(that is, in the
-plane), as a function of the optic-axis orientation
, and fulfilling the frequency-matching in degenerate form. We can see that the beam-like configuration (left vertices) is achieved at different orientations of the optical axis for different pump wavelengths. The same occurs for osculating configuration (intersections of the ellipses and the
-axis).
According to the notation introduced in the previous sections, we can write for the set of orientations of the optic axis that give rise to the beam-like configuration at one extreme and osculating configuration at the other, with the divergent configuration in between.
A striking feature of the results shown in
Figure 15 is that the width of
is around
, no matter the value of
(actually gives
for the blue and purple curves, and
for the red curve). It seems to us that this quantity so specific for the width of
is a characteristic of the crystal.
One way to verify our conjecture could be to measure the width of
for each of the wavelengths in
Figure 15 (and as many others as possible), and find that, in fact, the same result is obtained regardless of the value of
.
Remarkably, the experimental measurements reported in [
30], performed on a BBO crystal injected with a pump laser at 408 nm, give exactly the width
for
. This close agreement with our theoretical model represents the first step to verify the conjecture about the invariance of the width of
with respect to pump wavelength.
However, as far as we have been able to review, the available data regarding nm and nm are not useful to complete the verification of the above conjecture, since the relationship between the reported results with the optic-axis orientation is not explicitly provided.
Experimental measurements are outside the scope of this work. Therefore, the complete experimental corroboration of the width invariance of with respect to , and its adjudication as a property of BBO crystals remains an open question.
The other experimental results of [
30] are also in excellent agreement with our model. The beam-like and osculating configurations of converted light were observed at
and
, respectively. The difference with our theoretical result is
and
, see details in
Figure 15. In turn, the overlapping configuration, accomplished at
[
30], is also in agreement with our model (although not included in
Figure 15).
Another noteworthy aspect of the information shown in
Figure 15 is that the deviation
of the experimental optic axis orientation (
) from the theoretical result (
) implies different points of view about the configuration involved. Where the experimental measurements in [
30] yield a beam-like configuration, the theoretical result predicts a cone for the idler light.
In fact, at
the purple ellipse provides
and
, see the filled circles in
Figure 15. Then, we obtain the cone aperture
. In other words, tilting the optic axis at
the cone of idler light has not yet degenerated into a single beam, it still has structure.
To double-check the above result, let us analyze the behavior of the polar angles
on their respective
for
and
. In the former case,
Figure 16 shows that the left vertices of both ellipses
are precisely at
nm, which means degenerate production of photon pairs from a pump beam at
nm, verifying the beam-like behavior identified in
Figure 15 (two spots located symmetrically on the detection plane are expected). On the other hand, the spectrum at
gives two different values for both polar angles at
nm. The latter implies divergent configuration and, by necessity, the transverse pattern is formed by two separate rings.
Therefore, although the black star (experimental data) and the vertex of the purple curve (theoretical result) in
Figure 15 are in good agreement, we wonder about the structure of the spots reported in
Figure 1(c) of [
30]. Perhaps by placing the detection plane at a greater transverse distance from the crystal, an incipient ring structure could be observed.
In any case, as we have already discussed, the sensitivity of both theoretical and experimental results to small variations in for divergent and beam-like configurations is extremely remarkable.
Sensitivity to parameter variations is also seen in non-degenerate frequency matching, where small deviations from the degenerate frequency could imply going abruptly from a given configuration to beam-like or overlapping configurations. This would even mean stopping the related emission of converted photons, as explained in
Section 3.2.
An unexpected result of our theoretical model is the prediction of right-circular cones for down-converted light at
. The aperture of both cones is maximum and their axes coincide with the pump beam, so they overlap exactly to establish the configuration that we have called coaxial (
Section 3.1.2). We analyzed the conditions for the production of down-converted light in this configuration. Our results suggest that this configuration is feasible and that it is optimized along the
x-axis for vector phase-matching. The situation changes for scalar phase-matching since no down-converted light is produced such that its wave vector is aligned with the pump beam for
. However, the latter is completely consistent with the right-circular cones described above.
Our model is based on the exact solutions of vector phase-matching for nonlinear uniaxial crystals. It is known that the corresponding equations are strongly transcendental since the refractive indexes of extraordinarily polarized light are elaborated functions of the unknowns, and the latter is encapsulated by trigonometric functions. Over the years, this fact has motivated more the study of numerical approaches than the search for analytical solutions. However, we have shown that the complexity of solving the strongly transcendental equations of vector phase-matching is reduced by transforming them into a fourth-order polynomial equation.
All the results reported in this work have been obtained by requiring a reality condition for the four roots of the quartic equation since these are complex-valued in general. Such a condition defines a natural way to identify the orientations of the optical axis that are useful to produce down-conversion in the uniaxial crystal under study.
As we have seen, the model is in good agreement with the available experimental data. Theoretical predictions, such as the invariance of the width of under the change of the pump wavelength, modifications to the configurations of down-converted light due to non-degenerate frequency-matching, or the production of down-converted light forming right-circular cones for , await experimental verification.
It is expected that our approach can be extended to study biaxial crystals as well. In general, the three principal axes
,
, and
, are all different, and the intercepts of the wave vector surface identify two optic axes of the crystal [
34]. The case studied throughout this work corresponds to the situation in which two of the principal indices are equal, so there is only one optic axis (uniaxial crystal). For biaxial crystals it is usual to assume
. Then, according to the polarization of the beam in the crystal, one has at hand two different refractive indices [
35]:
and
where
and
are the angles formed by the wave vector and the optical axes.
Of particular interest, assuming that the wave vector is in the
-plane, one has
and
, with
the polar angle of the wave vector and
the angle formed by the optic axes. In this case, we have
It is easy to see from (
49) and (
7) that
behaves as the extraordinary refractive index of a uniaxial crystal. Similarly,
behaves as the ordinary index of such a uniaxial crystal since it does not depend on the direction of the wave vector. Therefore, under the conditions described above, our approach can be immediately extended to study the possibilities of SPDC in biaxial crystals. The analysis for arbitrary directions of the wave vector in biaxial crystals is beyond the scope of this work, so it will be reported elsewhere.